• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 566
  • 154
  • 15
  • 14
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 830
  • 385
  • 223
  • 103
  • 98
  • 95
  • 75
  • 74
  • 70
  • 69
  • 69
  • 67
  • 64
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

"Estimativa ultra-sonográfica e clínica do peso fetal" / Ultrasound and clinical fetal weight estimation

Aline Girotto Ricci 10 May 2006 (has links)
O objetivo deste estudo foi avaliar e comparar a eficácia da estimativa ultra-sonográfica e clínica na predição do peso fetal; analisar fatores maternos e fetais que poderiam interferir na estimativa ultra-sonográfica do peso fetal. Foram realizadas 212 avaliações, em até 24 horas do parto. Os fatores maternos avaliados foram peso, IMC e distância entre a pele e o útero; e os fetais constaram de apresentação, posição de dorso, localização e espessura placentárias, peso fetal e ILA. A estimativa ultra-sonográfica do peso fetal apresenta boa acurácia, já a clínica mostrou-se satisfatória na predição do peso no nascimento, embora com desempenho inferior à avaliação ultra-sonográfica. Quanto maior a distância entre a pele e o útero materno e quanto menor o peso fetal maior o erro na estimativa do peso / This study was designed to evaluate the accuracy of ultrasound and clinical fetal weight estimation; evaluate maternal and/or fetal factors that could interfere in ultrasound estimation of fetal weight and, compare the accuracy of ultrasound versus clinical fetal weight estimations. 212 estimation of fetal was performed within 24 hours to delivery. The maternal factors examined were: weight, BMI, skin to uterus distance, and as fetal factors: presentation, position, fetal weight, placental localization and thickness and AFI. Ultrasound presented good accuracy in the estimation of fetal weight. Thick distances between skin to uterus and small fetuses are associated to higher errors in estimating fetal weight. Clinical estimation of fetal weight was satisfactory in the prediction of birth weight, however with lower accuracy than ultrasound
332

Ultra-sonografia muscular cervical e pélvica de cães da raça Golden Retriever portadores e afetados pela Distrofia Muscular e em, terapia celular / Cervical e pelvic ultrasonography of Golden Retriever dogs carrying and affected by the Muscular Dystrophy and in cellular therapy

Juliana Passos Alves dos Santos 28 February 2008 (has links)
Os cães Golden Retriever com Distrofia Muscular (GRMD) são considerados modelos experimentais para estudo da Distrofia Muscular de Duchenne que acomete humanos, devido serem geneticamente homologas. Utilizamos o ultra-som muscular para avaliar a evolução terapêutica de injeção de células tronco (CT). Para este experimento utilizamos 8, sendo 6 afetados pela doença e 2 não afetados (portadora e macho normal). Avaliamos de forma qualitativa (visual) e quantitativa (digital) os músculos cervicais splenius e semispinalis capitis e o músculo pélvico semitendinosus e realizamos mensurações musculares. Em relação aos músculos cervicais verificamos que não há alteração visual na arquitetura das fibras, porém o cão tratado via arterial apresentou menores escores na análise digital em relação ao cão controle afetado, deixando suspeitas sobre a migração de CT nesse grupo muscular. O splenius apresentou maior ecogenicidade que o músculo semispinalis capitis em 7 animais. Para o músculo semitendinosus, a portadora apresentou ecogenicidade elevada; os afetados apresentaram variáveis graus de alteração da arquitetura muscular e aumento de ecogenicidade; o macho normal apresentou fibras regulares, porém em alguns exames apresentou ecogenicidade elevada podendo ser conseqüência da angulação do transdutor. Quanto às mensurações, há diferença entre os afetados e não afetados para o músculo splenius e devido à hipertrofia que afeta os músculos pélvicos, não foi possível estabelecer diferenças entre os dois grupos. Concluímos que a ultra-sonografia com transdutores de até 7,5 MHz não é viável para acompanhar evolução terapêutica de injeção de CT em músculos com a pseudohipertrofia de GRMD, devido a modificação severa da arquitetura, não sendo possível a detecção de prováveis reparos da musculatura. / The dogs Golden Retriever with Muscular Dystrophy (GRMD) are considered experimental models for study of the Muscular Dystrophy of Duchenne that acomete human, and they are genetically homologue. We use the muscular ultrasound to evaluate the therapeutical evolution of injection of stem cells (SC). For this experiment we use 8, being 6 affected for disease and 2 not affected (carrying and male normal). We evaluate of qualitative form (visual) and quantitative (digital) the cervical muscles splenius and capitis semispinalis and the pelvic muscle semitendinosus and carry through muscular mensure. In relation to the cervical muscles we verify that it does not have visual alteration in the architecture of fibres, however the treat dog saw arterial presented minors props up in the digital analysis in relation the dog has controlled affected, leaving suspicion on the migration of SC in this muscular group. Splenius presented greater echogenicity that the muscle semispinalis capitis in 7 animals. For the muscle semitendinosus, the carrier presented high echogenicity; the affected ones had presented variable degrees of alteration of the muscular architecture and increase of echogenicity; the normal male presented regular fibres, however in some examinations he presented high echogenicity being able to be consequence of the transducer angle. How much to the mensure, it has difference between the affected ones and not affected for the muscle splenius and due to hypertrophy that affects the pelvic muscles, it was not possible to establish differences between the two groups. We conclude that the ultrasonography with transducers of up to 7,5 MHz is not viable to follow therapeutical evolution of injection of SC in muscles with the pseudohypertrophy of GRMD, had the severe modification of the architecture, not being possible the detention of probable repairs of the muscle.
333

Avaliação morfométrica e hemodinâmica comparativa dos vasos envolvidos no desvio portossistêmico em cães / Morphometric and haemodynamic evaluation of the vases involved in the portosystemic shunts in dogs

Lilian Kamikawa 29 February 2008 (has links)
Foi realizado o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães normais, de idade igual e inferior a 120 dias, e em cinco cães portadores de desvio portossistêmico, de idades entre 90 e 360 dias. Dois animais do grupo de cães portadores de desvio portossistêmico foram submetidos ao tratamento cirúrgico (colocação de anel ameróide) e avaliações subseqüentes ao procedimento cirúrgico foram realizados. Nos cães do grupo normal, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm depois da margem costal. As médias dos diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas de VP, VCC e AO mediram respectivamente, 0,12cm2, 0,11cm2 e 0,14cm2. No estudo hemodinâmico de VP destes animais, utilizando-se o ultra-som Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,77cm/s. A média de fluxo sangüíneo portal (FSP) mediu 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,009. Para o grupo de cães portadores de desvio portossistêmico, o fígado apresentou redução de seu volume, sendo visibilizado entre 1,00cm e 2,00cm antes da margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO mensuraram respectivamente, 0,52cm, 0,79cm e 0,58cm. As proporções entre os diâmetros médios VP/VCC e VP/AO mediram respectivamente, 0,62 e 0,84. As médias das áreas de VP, VCC e AO mediram respectivamente, 0,22cm2, 0,56cm2 e 0,27cm2. Ao ultra-som Doppler a VMFSP mediu 26,10cm/s e a média do IC obtido foi de 0,009. Nos animais do grupo de cães portadores de desvio portossistêmico submetidos ao procedimento cirúrgico, foi observado aumento de volume hepático na semana seguinte à colocação do anel ameróide e a VMFSP manteve-se inferior a 19,50cm/s em todos exames subseqüentes à cirurgia no cão 1. / The morphometry and haemodynamic aspects of portal vein were studied in 20 normal dogs with less than 120 days of age and in 5 dogs presenting portosystemic shunting with ages between 90 and 360 days. 2 dogs of the group of animals with portosystemic shunting were submitted to surgical treatment, using a specialized device (ameroid constrictor). Subsequent evaluations were made after the surgical procedure. In the normal group the hepatic margins were seen 1.50cm to 3.00cm below de costal margin. Collected data indicated that the mean diameter of portal vein (VP), caudal vena cava (VCC) and abdominal aorta (AO) measured respectively, 0.38cm, 0.37cm and 0.41cm. The VP/VCC and VP/AO mean ratios were respectively, 1.10 and 0.94. The average of VP, VCC and AO areas were respectively, 0.12cm2, 0.11cm2 and 0.14cm2. The haemodynamic of portal vein was studied by ultrasound Doppler and the mean velocity of portal blood flow (VMFSP) measured was 17.77cm/s. It was verified that portal blood flow (FSP) average was 83.11ml/min/kg and the congestion index (IC) average was 0.009. In the group of animals presenting portosystemic shunting, the hepatic margins were seen 1.00cm to 2.00cm above the costal margin. The morphometry of VP, VCC and AO presented a mean diameter of 0.52cm, 0.79cm and 0.59cm, respectively. The VP/VCC and VP/AO mean ratios were respectively, 0.62 and 0.84. The average of VP, VCC and AO areas were respectively, 0.22cm2, 0.56cm2 and 0.27cm2. The haemodynamic study demonstrated that the VMFSP measured was 26.10cm/s and de IC average was 0.009. In the group of animals with portosystemic shunting which were submitted to surgical treatment, an increase of the liver size was seen from the first ultrasonographic evaluation. The measurements of VMFSP collected in the post surgical period were <= 19.50cm/s in dog 1.
334

Avaliação ultrassonográfica da musculatura mastigatória e da força de mordida molar máxima em indivíduos com osteoporose nos ossos da face / Ultrasound of the masticatory muscles and maximal molar bite force evaluation in individuals with osteoporosis in facial bones

Paulo Batista de Vasconcelos 24 June 2010 (has links)
O sistema estomatognático identifica um conjunto de estruturas bucais que desenvolvem funções comuns, tendo como característica constante a participação da mandíbula. Como todo sistema, tem características que lhe são próprias, mas depende do funcionamento, ou está intimamente ligado à função de outros sistemas como o nervoso, o circulatório e o endócrino. Tanto nos estados de saúde como nos de enfermidade, o sistema estomatognático pode influir sobre o funcionamento de outros sistemas como o digestório, respiratório e o metabólico-endócrino. Várias são as doenças que podem acometer o sistema estomatognático, acarretando o seu desequilíbrio ou mau funcionamento, dentre estas podemos citar a osteoporose. A osteoporose é a doença óssea metabólica mais frequente, sendo fratura e perda muscular manifestações clínicas mais evidentes. Esta doença não somente afeta os ossos da coluna, o colo do fêmur e a porção distal do rádio, como também os ossos da face. Tendo em vista que a perda óssea no esqueleto da face pode causar distúrbios na harmonia funcional do sistema mastigatório e, portanto, aumentar as possibilidades de desordens temporomandibulares, este estudo teve como objetivo analisar a espessura muscular e a força de mordida em 36 indivíduos diagnosticados com osteoporose na maxila e na mandíbula e em 36 indivíduos sem osteoporose (controles). Para a análise ultrassonográfica foi utilizado o ultrassom portátil da marca Sono Site Titan e um transdutor linear - L 38 - de 5 a 10 MHz e 38 mm. Foram adquiridas três imagens ultrassonográficas dos músculos masseter e temporal, de ambos os lados, na posição de repouso e de contração voluntária máxima. Os registros da força de mordida foram realizados utilizando o dinamômetro digital, modelo IDDK (Kratos). As avaliações foram feitas nas regiões do primeiro molar (direito e esquerdo). Verificou-se que, os indivíduos portadores de osteoporose na mandíbula e na maxila apresentaram espessuras musculares semelhantes a dos indivíduos sem a doença, enquanto que, os resultados para a força de mordida máxima foram significativamente menores para os indivíduos portadores de osteoporose. Conclui-se que a osteoporose na região dos ossos da face pode levar a alterações no sistema estomatognático. / The stomatognathic system identifies a set of oral structures that develop common functions, characterized by constant mandible involvement. Like any system, has features of its own, but depends on the operation, or is closely linked to the function of other systems such as the nervous, circulatory and endocrine systems. Both the states of health and in illness, the stomatognathic system can influence the operation of other systems such as digestive, respiratory and metabolic and endocrine systems. There are many diseases that can affect the stomatognathic system, causing your imbalance or malfunction; among these we can mention osteoporosis. Osteoporosis is the most frequent metabolic bone disease and fracture and muscle loss are the clinical manifestations. This disease not only affects spine bones, the neck of femur and the distal portion of radio, it also affects the facial bones. Considering that bone loss in the facial skeleton can cause disturbances in the functional harmony of the masticatory system and thus increase the chances of temporomandibular disorders, this study aimed to analyze the muscle thickness and bite force in 36 individuals diagnosed with osteoporosis the maxilla and mandible and 36 patients without osteoporosis (controls). For the ultrasound analysis was used Sono Site Titan portable ultrasound and a linear transducer - L 38 - 5 to 10 MHz and 38 mm. Three ultrasound images were acquired of masseter and temporal muscles on both sides, at rest and maximal clenching. To measure maximum bite force a digital dynamometer model IDDK (Kratos) was used. Assessments were made in the regions of the first molar (right and left). It was observed that muscle thickness in individuals with osteoporosis in the mandible and maxilla were similar of the individuals without the disease, while the results for the maximum bite force were significantly lower for individuals with osteoporosis. We conclude that osteoporosis in the region of facial bones can lead to changes in the stomatognathic system.
335

Eficácia da ultrassonografia endorretal tridimensional em relação ao exame anatomopatológico nas neoplasias de reto extraperitoneal / Efficacy of three-dimensional endorectal ultrasound in comparison to histopathology for evaluation of extra peritoneal rectal neoplasms

Rodrigo Ambar Pinto 26 November 2015 (has links)
INTRODUÇÃO: O câncer do reto médio e distal ainda é assunto bastante controverso, especialmente no que se refere ao estadiamento locorregional e opções terapêuticas. Busca-se um método sensível e específico para a avaliação da profundidade de invasão da parede retal e o envolvimento linfonodal. O adequado estadiamento da neoplasia do reto extraperitoneal é de suma importância no manejo terapêutico e prognóstico do paciente. Diversos métodos têm sido descritos para a avaliação da disseminação locorregional das neoplasias do reto, que variam desde o toque retal até a ressonância magnética da pelve e a ultrassonografia endorretal bi e tridimensional. OBJETIVO: Correlacionar os achados da profundidade de invasão tumoral na parede retal (T), comprometimento linfonodal (N), extensão e porcentagem de acometimento da lesão à ultrassonografia endorretal tridimensional (USER-3D) com o exame anatomopatológico (AP) de pacientes portadores de neoplasia de reto extraperitoneal submetidos a procedimento cirúrgico após o diagnóstico e estadiamento clínico prévio. MÉTODO: Estudo prospectivo foi realizado com pacientes portadores de neoplasia de reto médio e distal seguidos no Instituto Central (IC) e no Instituto do Câncer do Estado de São Paulo (ICESP), do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) que foram submetidos a USER-3D pré-operatório. Os parâmetros analisados por meio do USER-3D foram comparados aos achados da anatomia patológica do espécime cirúrgico obtido após o procedimento. Os exames de USER-3D foram realizados pelo mesmo médico, sendo cego dos outros métodos diagnósticos e dos achados da patologia, a qual também não tinha os resultados do estadiamento clínico pré-operatório. Todos os pacientes foram submetidos a enema evacuatório no dia anterior e na manhã do exame. Foram avaliados a sensibilidade, especificidade, valores preditivos positivo e negativo, área sobre a curva e o índice Kappa do USER-3D em comparação ao anatomopatológico, considerado exame padrão ouro. O coeficiente de correlação intraclasse (CCI) foi utilizado para analisar a extensão e porcentagem de acometimento da lesão na parede retal. RESULTADOS: No período de 3 anos, 44 pacientes foram estudados, 27 mulheres, com idade média de 63,5 anos. Houve 12 lesões benignas e 32 malignas de reto, sendo 30 submetidas à ressecção local e 14 à radical. O USER-3D determinou a diferenciação da profundidade de invasão tumoral na submucosa com sensibilidade de 77,3% (CI95% - 54,6%-92,2%), especificidade de 86,4% (CI95% - 65.1%-97.1%), valor preditivo positivo de 85% (CI95% - 62,1%-96,8%), valor preditivo negativo de 79,2% (CI95% - 57,8%-92,9%) e área sobre a curva de 0,82% (CI95% - 0,7%-0,96%). O índice Kappa ponderado para profundidade de invasão da parede retal (T) foi de 0,672 (IC95%: 0,493; 0,850), considerado grau de concordância substancial. Para o envolvimento linfonodal (N) não houve concordância adequada entre o USER-3D e o anatomopatológico (k=-0,164) nos 14 casos analisados. A CCI calculada para extensão da lesão foi moderada (0,45) para a extensão em centímetros, mas adequada (0,66) para porcentagem de envolvimento da circunferência. O gráfico de Bland-Altman mostrou que lesões com extensão de até 5 cm e 50% de acometimento têm melhor correlação com o espécime cirúrgico. CONCLUSÕES: USER-3D foi eficaz para a determinação da invasão da parede retal, sendo seguro na determinação da extensão de lesões até 5 cm e porcentagem de acometimento da circunferência até 50%. O método mostrou baixa eficácia na avaliação linfonodal, em subgrupo limitado de pacientes / INTRODUCTION: Loco-regional staging and treatment of extra peritoneal rectal neoplasms is still a controversial subject. There is no perfect method, substantially sensitive and specific for staging rectal wall invasion and lymph node involvement. Adequate oncologic staging of rectal neoplasias has major importance in both, treatment and prognostic evaluation. Therefore, the use of supplementary diagnostic methods such as endorectal ultrasound (ERUS) and magnetic resonance imaging (MRI) of the pelvis can promote an accurate assessment of tumor invasion in the rectal wall and lymph node involvement. OBJECTIVE: To correlate the findings of three-dimensional (3D) ERUS with pathology specimen of extra peritoneal rectal neoplasia referred directly to surgery after diagnosis, in regards to depth of rectal wall invasion (T), lymph node involvement, percentage of circumferential rectal wall invasion and tumor extension. METHODS: A prospective study was performed in patients with middle and distal rectal tumors followed at University of São Paulo, School of Medicine and Cancer Institute of State of São Paulo (ICESP), who underwent 3D-ERUS for preoperative evaluation. The parameters analyzed with 3D-ERUS were compared with pathology findings of the surgical specimen obtained after the procedure. A single doctor who performed the exams reported the 3D-ERUS studies and was blind of other methods as well as the pathologic findings. All patients underwent retrograde bowel enema the day before and in the morning of the test. The authors evaluated sensitivity, specificity, positive and negative predictive values, area under curve and kappa index of the 3D-ERUS as compared to pathologic findings, considered the gold standard. For extension and percentage of tectal wall involvement intraclass correlation index was applied. RESULTS: At 3-years period, 44 patients were studied, 27 females, with a mean age of 63.5 years, who had 12 rectal adenomas and 32 adenocarcinomas and underwent local resection (30) or radical resection (14). Value for 3D-ERUS to determine depth of rectal wall invasion sensitivity was 77.3% (CI95% - 54.6%-92.2%), specificity was 86.4% (CI95% - 65.1%- 97.1%), positive predictive value was 85% (CI95% - 62.1%- 96.8%), negative predictive value was 79.2% (CI95% - 57.8%-92.9%) and area under curve was 0,82% (CI95% - 0.7%-0.96%). The weighted kappa index for the depth of invasion in the rectal wall (T) evaluation was 0.67 (IC95%: 0.49; 0.85), considered substantial agreement. For N involvement there was any agreement between 3D-ERUS and histopathology, with K=-0.164. Intraclass correlation was calculated for lesion extension and was moderate (0.45) for extension in centimeters and adequate (0.66) for percentage of circumference involvement. A Bland-Altman graph was performed and showed that tumor extensions until 5 cm and 50% of wall involvement have a good correlation to specimen size. CONCLUSION: 3D-ERUS was effective for determining rectal wall invasion and evaluation of extension of lesions until 5 cm and 50% of rectal wall involvement. However, this method showed a lack of efficacy for evaluation of lymph node involvement for early rectal tumors in this limited subset of patients
336

Hemodinâmica venosa de membros inferiores em mulheres durante a gestação e após o parto / Venous lower limb hemodynamics during Pregnancy and puerperium

Leandro Augusto Gardenghi 19 February 2016 (has links)
Contexto: Existem controvérsias na literatura médica sobre potenciais alterações da hemodinâmica venosa dos membros inferiores durante a gravidez. Objetivo: Estudar a drenagem venosa em membros inferiores e suas alterações na gestação (1º, 2º e 3º trimestres) e pós-parto mediante Mapeamento Dúplex (MD) das veias profundas e superficiais e a Pletismografia a Ar (PGA). População: Foram recrutadas vinte mulheres primigestas, sem doença venosa prévia, junto aos Núcleos de Saúde da Família ligados ao Centro de Saúde Escola da FMRP-USP. Métodos: O estudo hemodinâmico venoso nos membros inferiores foi realizado empregando-se dois métodos não invasivos: o MD e a PGA. Foram registrados os diâmetros e os refluxos das principais veias (femoral comum, femoral, poplítea, safena magna e parva) dos membros inferiores por meio do MD. Foram avaliados pela PGA: o índice de enchimento venoso (IEV), a fração de ejeção (FE), a fração de volume residual (FVR) e o esvaziamento venoso (OF-outflow). Todos os registros foram obtidos em 3 diferentes períodos da gestação e no pós-parto. Os dados foram estatisticamente analisados e considerou-se p?0,05. Resultados: Houve aumento do diâmetro venoso no território da femoral comum e da safena magna infravalvar bilateralmente, nos 2º e 3º trimestres. Na PGA, registrou-se diminuição da FVR bilateral, elevação do IEV à direita e aumento do OF bilateral no decorrer da gestação. Observou-se edema em 4 (15%) gestantes no segundo trimestre e 11 (55%) no terceiro trimestre. Quanto ao refluxo, documentouse um caso no 2º trimestre no território da safena magna supravalvar esquerda (5%) e mais dois casos no 3º trimestre (15%), sendo uma no território da safena magna infravalvar esquerda e outra gestante com refluxo nos territórios de safena magna infravalvar e safena parva esquerdas. Após o parto, houve regressão de todas essas alterações anatômicas e hemodinâmicas da drenagem venosa dos membros inferiores. Conclusão: Apesar do aumento significativo dos diâmetros das veias femorais comuns e safenas magnas infravalvares bilateralmente, diminuição da FVR bilateral, elevação do IEV à direita, aumento do OF durante a gestação, todas essas alterações retornaram aos parâmetros anatômicos e hemodinâmicos venosos iniciais, após o parto / Background: The relation between pregnancy and venous reflux is still misunderstood and some authors question if pregnancy is the main cause of venous reflux and venous disease. Objective: analyze venous hemodynamics in healthy primigravidae during the first, second and third trimester of pregnancy and in the puerperium. Methods: prospective study with 20 primigravidae evaluated in the first, second and third trimester of pregnancy and postpartum. Duplex scan evaluated venous diameters and reflux; air plethysmography evaluated venous filling index (VFI), ejection fraction (EF), residual volume fraction (RVF), outflow fraction (OF )in both limbs. OF in the right limb while the patient was in left lateral decubitus position was also evaluated. Results: During pregnancy, there was bilateral increase in venous diameters in common femoral and infravalvar great saphenous veins; occurrence of reflux in the left surpravalvar great saphenous vein in one patient (5%) in the second trimester; and occurrence of reflux more other two patents (15%) in the third trimester: one in the left infravalvar great saphenous vein, and other in the left popliteal and small saphenous vein. All these alterations observed during pregnancy disappeared after delivery. VFI decreased after delivery in the left limb, but increased progressively in the right limb, returning to basal level after delivery; EF did not change; RVF decreased during pregnancy, mainly in left limb, and returned to basal level after delivery; OF increased during pregnancy and returned to basal levels after delivery; OF in left lateral decubitus did not change. Conclusion: pregnancy caused a diameter increase in bilateral common femoral and great saphenous veins, unilateral right increase in VFI, bilateral decrease in the RVF and bilateral increase in OF. All these parameters returned to initial status after delivery
337

Estudo da morbidade residual da esquistossomose mansônica através da ultra-sonografia no município de Bananal, São Paulo, Brasil / Study on residual morbidity from schistosomiasis by means of ultrasonography in the municipality of Bananal, São Paulo, Brazil

Maria Cristina Carvalho do Espirito Santo 27 November 2006 (has links)
Este estudo desenvolveu-se no município de Bananal, São Paulo, uma área endêmica para esquistossomose com prevalência menor que 10% e baixa carga parasitária dos infectados. Teve como objetivo a identificação de formas clínicas da esquistossomose mansônica entre 109 pacientes diagnosticados parasitoscopicamente e medicados com oxamniquine, durante a realização do Plano de Intensificação das Ações de Controle da Esquistossomose Mansônica (1998-2000). Utilizou-se a ultra-sonografia abdominal e o exame de fezes (Kato-Katz) realizado, em média, quatro anos após o término do plano. Nesta casuística, foram identificados cinco pacientes com imagens ultra-sonográficas abdominais compatíveis com fibrose periportal periférica e central e hipertensão portal que tinham diagnósticos clínicos de esquistossomose na sua forma intestinal. A ultra-sonografia é um método de diagnóstico sensível, incruento, que possibilitou a identificação de casos de esquistossomose com comprometimento hepático mais extenso do que se expressava pelo exame físico. Mesmo considerando uma prevalência baixa de alterações hepáticas e de circulação portal nesta casuística, evidencia-se a importância do emprego do método ultra-sonográfico na avaliação individual dos pacientes esquistossomóticos, por permitir a detecção de alterações morfológicas e funcionais que podem ter conseqüências clínicas relevantes. Deve-se assinalar ainda que, no momento do exame, todos os pacientes tiveram coproscopias negativas, revelando a efetividade das ações de controle no médio prazo. Devemos considerar que a realização do estudo ultra-sonográfico em média quatro anos após o tratamento específico dessa população, provavelmente detectou menos alterações do que aconteceria se o estudo fosse feito no momento do diagnóstico parasitológico, pois se sabe que a involução, ainda que parcial da fibrose e de alterações funcionais conseqüentes a ela, ocorre após tratamento específico. Por fim, apesar do pequeno número de casos avaliados, a estratégia utilizada no presente trabalho começou a preencher a lacuna de avaliação do impacto da esquistossomose sobre a saúde do cidadão bananalense, percebida durante o desenvolvimento do Plano de Intensificação das Ações de Controle da Esquistossomose Mansônica, período de 1998 a 2000. / This study was developed in the municipality of Bananal, São Paulo, an endemic area for schistosomiasis with prevalence of less than 10% and low parasite load among infected individuals. The objective was to identify the clinical forms of intestinal schistosomiasis among 109 patients who had been diagnosed through parasitological tests and medicated with oxamniquine at the time of the Plan for Intensification of Schistosomiasis Control Actions (1998-2000). Abdominal ultrasonography and feces examination (Kato-Katz) were utilized: this was on average done four years after the ending of the plan. In this sample, five patients were identified whose abdominal ultrasound images were compatible with peripheral and central periportal fibrosis and portal hypertension who had had a clinical diagnosis of schistosomiasis in its intestinal form. Ultrasonography is a sensitive noninvasive diagnostic method that enables identification of the extent of liver involvement in schistosomiasis cases better than through its expression in physical examination. Even considering that there was a low prevalence of liver abnormalities and portal circulation in this sample, the importance of utilizing the ultrasound method for individual evaluations on the schistosomiasis patients was demonstrated. Through this, it was possible to detect morphological and functional alterations that could have important clinical consequences. It also should be noted that, at the time of the ultrasound examination, all the patients presented negative coproscopic test results, thus showing the effectiveness of the control actions over the medium term. It needs to be borne in mind that, because the ultrasound study was carried out on average four years after the specific treatment of this population, it is likely that fewer abnormalities were detected than there would have been if this study had been performed at the time of the parasitological diagnosis. This comes from the knowledge that involution occurs following specific treatment, even if only partially with regard to fibrosis and its consequent functional alterations. Finally, despite the small number of cases evaluated, the strategy utilized in the present study has started to fill the gap regarding assessing the impact of schistosomiasis on the health of the citizens of Bananal that was perceived during the development of the Plan for Intensification of Schistosomiasis Control Actions between 1998 and 2000.
338

Ultra-sonografia mamária na identificação e orientação de biópsia percutânea das microcalcificações agrupadas / Breast sonography: role in detection and ultrasound-guided core biopsy of clustered microcalcifications

Flávio Spinola Castro 14 January 2004 (has links)
Os objetivos deste estudo são: 1) avaliar a capacidade de se demonstrar, através da ultra-sonografia, microcalcificações agrupadas, previamente identificadas pela mamografia. 2) identificar parâmetros mamográficos dos agrupamentos de microcalcificações e correlacionar com a positividade da ultra-sonografia na caracterização destas lesões. 3) avaliar a possibilidade de a ultra-sonografia mamária servir de guia de biópsias dirigidas, através de agulha grossa (biópsia percutânea de fragmento - \"core biopsy\"), nestas lesões. Entre dezembro de 2000 e abril de 2002, foram avaliadas através da ultra-sonografia, 68 pacientes com 70 focos de microcalcificações agrupadas na mamografia, suspeitas para neoplasia maligna, classificadas segundo critério de BI-RADSTM nas categorias 4 e 5, sem outras alterações mamográficas associadas, como distorções ou massas. Características das lesões na mamografia, como tamanho e profundidade do foco, foram avaliadas e os exames ultra-sonográficos foram classificados como positivos, quando as microcalcificações foram claramente identificadas e, negativos, quando não identificadas. Nas lesões positivas foram realizadas biópsias percutâneas de fragmento (\"core biopsy\"), através da ultra-sonografia e radiografia dos fragmentos. Nas negativas, os procedimentos foram guiados pela esterotaxia. Características ultra-sonográficas das lesões positivas foram analisadas e resultados anatomopatológicos foram correlacionados. Dos 70 focos de microcalcificações, 26 foram identificados através da ultra-sonografia (37,1%), sendo submetidas a biópsias guiadas pela ultra-sonografia e 44 não foram identificadas (62,9%). O tamanho médio dos focos de microcalcificações foi significativamente maior nos casos positivos ao ultra-som - 14,0 mm, em relação aos negativos - 7,6 mm (p< 0,001). Na avaliação da profundidade dos focos, a identificação positiva pela ultra-sonografia foi significativamente maior nos casos de lesões no terço anterior, mais superficiais (16/26 - 61,5%) em relação às intermediárias (8/26 - 30,8%) e nas posteriores, mais profundas (2/26 - 7,7%) - Chi Square (p< 0,002). Avaliando as características ultra-sonográficas dos achados, em 6 identificou-se massa associada (6/26 - 23,1%), Nas outras, foram identificados pontos hiperecogênicos em meio ao tecido adiposo em 13 (13/26 - 50%); na parede de cistos em 5 (5/26 - 19,2%) e no interior de ductos em 2 (2/26 - 7,7%). Foram diagnosticados 12 casos de câncer, sendo que 8 foram identificados através da ultra-sonografia (8/12 - 66,7%) e 4 não (4/12 - 33,3%). Das 26 biópsias orientadas pela ultra-sonografia, em 18 delas (18/26 - 69,2%) foram identificadas microcalcificações nas radiografias dos fragmentos e em 8 não (8/26 - 30,8%). Nos 8 casos positivos para câncer, o diagnóstico foi subestimado em 3 delas (37,5%) em comparação com resultado anatomopatológico final da cirurgia. A ultra-sonografia apresenta uma sensibilidade baixa na identificação de focos de microcalcificações, previamente vistos na mamografia. O diâmetro médio dos focos de microcalcificações identificados na ultra-sonografia é maior do que nos não identificados. A ultra-sonografia identifica melhor focos de microcalcificações situados no terço anterior da mama, mais superficiais, em números percentuais maiores que no intermediário e posterior. A identificação de focos de microcalcificações ao ultra-som permite que biópsias de fragmento sejam realizadas, orientadas por este método / The present study aims to (1) evaluate sonographic ability of demonstrating clustered microcalcifications previously detected on mammographic examination, (2) demonstrate mammographic patterns of clustered microcalcifications and its correlation to sonographic characterization of lesions, and (3) evaluate clinical feasibility of using ultrasound-guided core biopsy of suspicious microcalcifications. Sixty eight patients with 70 clusters of mammographically detected suspicious microcalcifications - classified as category 4 or 5 according to ACR BI-RADS(TM) - and without associated findings, such as architectural distortions or nodules, underwent sonographic examination between December/2000 and April/2002. Examinations were considered positive when microcalcifications were clearly demonstrated and negative otherwise. In the former, ultrasound-guided core biopsy was performed, including specimen radiograph, and sonographic findings were correlated to histopathological results. In the latter, patients underwent stereotactic biopsy. Among 70 clusters of microcalcifications, 26 were demonstrated on sonography (37,1%) and these patients underwent ultrasound-guided core biopsy, while 44 lesions were not detected on sonographic examination (62,9%). The median size of lesions seen on sonography was significantly greater - 14.0 mm -, in contrast to the median size of lesions not detected - 7.6 mm (p<0.001). Considering the location of microcalcifications, sonographic detection of lesions was significantly more frequent in patients with microcalcifications in the anterior third of breast parenchyma (16/26 - 61.5%), when compared to those in the mid third (8/26 - 30.8%) and posterior third (2/26 - 7.7%) (p<0.002). Cancer was demonstrated in 12 patients, 8 of them using ultrasound-guided biopsy (8/12 - 66.7%) and 4 using stereotactic biopsy (4/12 - 33.3%). Microcalcifications were demonstrated on specimen radiographs in 18 out of 26 ultrasound-guided core biopsies (18/26 - 69.2%), and it was not possible to detect them on specimen radiographs in 8 patients (8/26 - 30.8%). Between 8 patients with cancer demonstrated using ultrasound-guided core biopsy, diagnosis was underestimated in 3 (37.5%), in comparison to 1 patient out of 4 (25%) who underwent stereotactic biopsy. Sonographic examination has low sensitivity in detection of clustered microcalcifications previously seen on mammography. The median diameter of lesions demonstrated on sonography is greater than that of microcalcifications not detected. Clusters of microcalcifications in the anterior third of breast parenchyma were also detected more frequently than lesions situated more posteriorly. Sonographic detection of clustered microcalcifications allows performing ultrasound-guided core biopsy
339

Nível sérico de ácido hialurônico e sua relação com o escore ultra-sonográfico na avaliação da hepatopatia em pacientes com fibrose cística

Rocha, Renata Gonçalves January 2007 (has links)
A hepatopatia da fibrose cística (FC) é uma complicação grave sendo descrita como terceira causa de morte nestes pacientes. Sua prevalência é muito variável, desde 14,3% até 41% em crianças e adolescentes. A discrepância entre os diferentes estudos clínicos se deve à forma utilizada para o diagnóstico da hepatopatia (características clínicas, bioquímicas e/ou ultra-sonográficas), à idade dos pacientes selecionados, ao tipo de estudo empregado (transversal ou longitudinal) e também, à falta de um marcador específico e sensível de disfunção hepatobiliar. Em 1995, Williams et al, elaboraram um escore ultra-sonográfico que mostrou boa relação com as alterações laboratoriais hepáticas pretendendo, desta forma, graduar o nível da lesão hepática. O escore foi elaborado por meio da avaliação do padrão do parênquima hepático, do contorno do fígado e do grau de ecogenicidade periportal. Quanto aos marcadores não invasivos para diagnosticar a doença hepática, vários tem sido estudados, entre eles o ácido hialurônico (AH).O AH é o maior mucopolissacarídeo componente da matriz extracelular, é encontrado na maioria dos tecidos e fluidos corporais, particularmente abundante em tecido conectivo frouxo. É sintetizado na membrana citoplasmática de fibroblastos e de outras células, sendo que uma pequena parte é metabolizada neste local. Através dos vasos linfáticos chega à corrente sanguínea e é rapidamente eliminada pelo fígado, ao nível do sinusóide hepático. Neste estudo buscamos relacionar as alterações ultra-sonográficas com o nível sérico de AH e, desta forma, realizar o diagnóstico precoce da hepatopatia da FC. Foi realizado um estudo transversal em 57 pacientes com FC, todos caucasóides, que apresentavam uma média de idade de 10,2 + 4,9 anos. A avaliação constou de dados clínicos, laboratoriais e ultra-sonográficos. Os pacientes foram classificados de acordo com um escore ultra-sonográfico em:Grupo 1 (G1) – ausência de doença hepática: escore 3; - Grupo 2 (G2) – doença hepática moderada: escore 4 – 6; - Grupo 3 (G3) – doença hepática grave: escore 7 - 9. O nível sérico do ácido hialurônico foi medido através da técnica de ELISA (Enzyme Linked Immunoassay) e comparado com 23 controles saudáveis. Vinte e nove pacientes foram incluídos no G1, dezoito pacientes no G2 e dez pacientes no G3. Os pacientes do sexo masculino apresentaram escore ultra-sonográfico mais alterado (P= 0,018). O nível sérico da ALT e da AST foram consideravelmente mais elevados no G3 do que no G1. O nível sérico da GGT foi mais elevado no G3 do que no G1 e G2. A porcentagem do volume expiratório forçado no primeiro segundo (%VEF1) apresentou uma correlação positiva fraca com o escore Z P/I (r= 0,31/P= 0,031). O nível sérico de AH variou de 1,8 a 45 ng/mL (mediana= 13,9), apresentou uma mediana semelhante entre os grupos 1,2,3 e o grupo controle (P= 0,431), entre os grupos 1,2 e 3 (P= 0,24) e também, quando comparado cada grupo com o grupo controle (todos P> 0,1). Não houve correlação entre o nível sérico de AH e o escore ultra-sonográfico (P= 0,164). Desta forma, concluímos que o AH isoladamente não se mostrou um marcador da hepatopatia causada pela fibrose cística. / Cystic fibrosis (CF) liver disease (LD) is a serious complication, being described as the third cause of death in these patients. Its prevalence varies widely, from 14.3% to 41.0% in children and adolescents. The discrepancy shown by the various clinical studies is due to the method employed for the diagnosis of LD (clinical, biochemical and/or ultrasonographic characteristics), the age of selected patients, the type of study (crosssectional or longitudinal) and the absence of a specific and sensitive marker. In 1995, WILLIAMS et al, developed an ultrasonographic score that showed a good relation to liver biochemical alterations, in order to measure the liver involvement. The score was elaborated through an evaluation of three cardinal features of hepatic ultrasound in CF: coarseness of the parenchyma, nodularity of the liver edge and increased periportal echogenicity. Regarding non-invasive markers to diagnose the hepatic disease, several have been studied, among them the hyaluronic acid (HA). Hyaluronic acid is a major mucopolysaccharide in the extracellular matrix, found in most body tissues and fluids, particularly abundant in loose connective tissue. It is synthetized in the cytoplasmatic membrane of fibroblasts and other cells, with a small part being metabolized there. Through the lymph vessels, it reaches the bloodstream and is rapidly eliminated by the liver, at the hepatic sinusoid level. In this study, we attempted to correlate the ultrasound findings with HA serum level, and thus, obtain the early diagnosis of CFLD. A cross-sectional study was performed with 57 patients with CF, all white individuals presenting mean age of 10.2 + 4.9 years. The evaluation considered clinical, laboratorial and ultrasonographic data. The patients were classified according to an ultrasonographic score into: - Group 1 (G1) – absence of liver disease: score 3- Group 2 (G2) – moderate liver disease: score 4 – 6; - Group 3 (G3) – severe liver disease: score 7 - 9. HA serum level was measured by ELISA (Enzyme Linked Immunoassay) in the CF patients and 23 healthy controls. Twenty-nine patients were included in G1, 18 in G2 and 10 in G3. The male patients presented an ultrasonographic score with more alterations (P= 0,018). The serum levels of ALT and AST in G3 were considerably higher than in G1. The serum level of GGT in G3 was higher than in G1 and G2. The percent of forced expiratory volume in the first second (%FEV1) presented a small positive correlation with Z score W/A (r= 0.31/P= 0.031). HA serum level ranged from 1.8 to 45 ng/mL (mean = 13.9), and presented a similar mean value between Groups 1,2,3 and the control group (P= 0.431), among Groups 1,2 and 3 (P= 0.24), as well as when comparing each group to the control group (all P> 0.1). There was no correlation between HA serum level and ultrasonographic score (P= 0.164). Thus, we concluded that HA lonely cannot be considered as a marker of liver disease caused by cystic fibrosis.
340

Associações entre qualidade muscular, adiposidade, saúde vascular e funcionalidade de indivíduos obesos

Rech, Anderson January 2014 (has links)
Os níveis de obesidade vêm aumentando, no Brasil e no mundo, de maneira exponencial. A condição de excesso de tecido adiposo pode gerar um prejuízo funcional, bem como alterações em uma série de parâmetros de saúde cardiovascular. A quantidade e qualidade muscular apresentada por um indivíduo obeso podem ser determinantes na maneira como o organismo lida com esses desafios. Dessa forma, o objetivo do presente estudo foi verificar a existência de associação entre variáveis de força, qualidade e quantidade muscular, funcionalidade, saúde vascular e adiposidade em indivíduos obesos. Para isso, trinta e quatro indivíduos obesos, com idade entre 20-60 anos, sedentários, não fumantes e não diabéticos, se voluntariaram a participar do estudo. Após prévia familiarização, foram realizados testes de força nos extensores de joelho (contração isométrica voluntária máxima - CIVM ; 1 repetição máxima - 1RM; potência média) e funcionalidade (teste de caminhada de 6 minutos - TC6M; sentar e levantar em 30 segundos - SL30; get up and go). A massa muscular (EMQUA) e echo intensity do quadríceps femoral (EIQUA) foram medidas por ultrassonografia, bem como diferentes parâmetros de adiposidade e função endotelial (avaliada por dilatação mediada por fluxo - DMF). Foram verificados os coeficientes de correlação de pearson entre as variáveis acima citadas e adotou-se um p<0.05 para associação significativa. Foi encontrada uma associação negativa significativa entre a EIQUA e todos os testes de força analisados, bem como com os testes funcionais. A EMQUA também apresentou correlação significativa, porém positiva, com os testes de força e funcionalidade. A EIQUA apresentou uma associação significativa com a gordura visceral, bem como com a gordura subcutânea da coxa. Além disso, a gordura subcutânea abdominal apresentou associação significativa com a DMF. Os dados do presente estudo mostraram haver uma associação significativa entre a quantidade e qualidade muscular e o desempenho em testes de força e funcionais em indivíduos obesos. Ainda, importantes parâmetros de adiposidade se correlacionaram com a EIQUA e com a DMF, um importante marcador de saúde endotelial. Dessa forma, estartégias de intervenção (por exemplo, treinamento de força), que sejam capazes de modificar os parâmetros acima descritos, devem ser priorizadas quando o objetivo for uma melhora na qualidade de vida de indivíduos obesos. / Obesity levels are increasing in Brazil and all over the world in an exponential way. The adipose tissue excess may affect functionality, as well as another health parameters. The skeletal muscle quantity and quality in obese individual may be determinant in how that the organism deals with theses problems. Thus, the objective of the present study was to verify the association between strength, muscle quantity and quality, functionality, vascular health and adiposity in obese subjects. Thirty four obese subjects, aged 20-60 years, sedentary, non-smokers and non-diabetic, volunteered to participate in the study. After a familiartization session, the knee extensors strength (isometric maximal volunatry contraction - IMVC; on repetition maximum - 1RM ; average power) and functional (6 minutes walk test - TC6M; sit to stand up test - 30SL; get up and go) tests were performed. The quadriceps femoris muscle thickness (EMQUA) and echo intensity (EIQUA) were evaluated by ultrasonography, as well as different adiposty parameters and vascular function. The pearson correlation coefficent were verified between all variables cited above and a P<0.05 were adopted. There was found a negative significant association between the EIQUA and all the strength tests performed, as well as all functional tests. The EMQUA presented significant positive association with all strength and functional tests. Additionally, the EIQUA presented a significant negative association with the visceral adipose tissue, as well as the thigh subcutaneous adipose tissue. Besides that, the abdominal subcutaneous adipose tissue was associated positively with the vascular function. The data presented here have shown a significant association between the muscle quantity and quality and the performance in functional and strength tests in obese subjects. In addition, important adiposity parameters correlated with the EIQUA and vascular function. Thus, intervention strategies (such as strength training), that are capable of modifying these parameters, should be prioritized when the objective is to enhance the quality of life in an obese person.

Page generated in 0.0558 seconds