• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 699
  • 518
  • 168
  • 123
  • 77
  • 36
  • 23
  • 16
  • 15
  • 11
  • 10
  • 7
  • 6
  • 6
  • 6
  • Tagged with
  • 1984
  • 480
  • 339
  • 339
  • 209
  • 191
  • 188
  • 163
  • 154
  • 140
  • 128
  • 123
  • 116
  • 108
  • 106
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1521

Estudo de métodos visando à análise direta de alumina, cimento e quartzo em ICP OES / Studies of methods aiming the direct analysis of alumina, cement and quartz by ICP OES

Alexandre Luiz de Souza 29 July 2011 (has links)
O objetivo deste estudo foi avaliar parâmetros para o desenvolvimento de métodos visando à determinação elementar em alumina, cimento e quartzo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) com amostragem de suspensão. Alguns elementos foram investigados como possíveis candidatos a padrões internos (PIs) Be, Dy, Gd, In, La, Sc, Y, Yb eTl. Amostras de material de referência certificado (CRM) de alumina (Alumina Reduction Grade 699), de cimento Portland (1889a Blended with Limestone e 1886a White Portland cement with low iron) do National Institute of Standard and Technology (NIST), e amostras de quartzo, cedidos pelo Departamento de Física da Universidade Federal de São Carlos (UFSCar), denominados T-4FI, T-2FI e T-4GR, foram utilizadas na otimização instrumental, no desenvolvimento e na avaliação da exatidão do método. Nanopartículas de sílica de alta pureza (Wacker HDK® T40), Wacker Chemie AG foram utilizadas no estudo de adsorção dos elementos e padrões internos como proposta de produção de material calibrante para a análise direta de sólidos. Para a escolha dos PIs foram construídos gráficos de correlação usando valores de potenciais de excitação, energias de ionização e temperaturas de fusão dos analitos e dos candidatos a PIs. Análise exploratória por agrupamentos hierárquicos (HCA) e análise dos componentes principais (PCA), também foram realizadas. A avaliação de desempenho do ICP OES foi feita em meio das suspensões das amostras a partir do estabelecimento de figuras de mérito como sensibilidade, robustez, seletividade e repetibilidade. Na otimização do foram considerados os parâmetros potência, vazão de nebulização e vazão de gás auxiliar. A determinação de Ca, Fe, Ga, Na, Si e Zn em alumina foi feita após dissolução em forno de micro-ondas com posterior precipitação do Al(III) com NH3. O uso de padrão interno foi essencial para a exatidão do método, com recuperações do CRM que variaram de 83 a 117%. Para a matriz cimento foram avaliados o efeito da concentração de ácido nítrico na extração dos analitos ( Al, Ca, Cr, Fe, K, Mg, Mn, Na, P, S, Si, Sr, Ti e Zn) e na adsorção dos elementos candidatos a PIs (Be, Sc, In, Dy). As determinações por suspensão e uso de padrão interno (exceto para Cr, S e Zn), com 0,5% v v-1 de HNO3, nebulizador Burgener e condições robustas do ICP geraram resultados com recuperações entre 68 e 119%. As determinações de Al, Ba, Cr, Fe, K, Li, Mg, Na, Sr e Ti em quartzo foram executadas com introdução de suspensão e ausência de padrão interno, usando condições do ICP similares àquelas adotadas na determinação elementar para matriz de cimento. Nesse caso as recuperações variaram de 90 a 107%. A adsorção dos analitos e padrões internos sobre as nanopartículas de sílica pode ser uma alternativa para a preparação de padrões de calibração quando se deseja realizar a introdução direta do material sólido em suspensão. / The aim of this study was to evaluate parameters for the development of methods for elements determination in alumina, cement and quartz by inductively coupled plasma optical emission spectrometry (ICP OES) with slurry sampling. Some elements were investigated as candidates for internal standards (ISs) Be, Dy, Gd, In, La, Sc, Y, Yb and Tl. Samples of certified reference material (CRM) of alumina (Alumina Reduction Grade - 699), Portland cement (blended with the 1889a and 1886a Limestone White Portland cement with low iron) from the National Institute of Standards and Technology (NIST), and quartz samples, suplied by the Department of Physics from Federal University of São Carlos (UFSCar), named T-4FI, T-2FI and T4GR were used to optimize instrumental, method development and accuracy evaluation of the method. Nanoparticles of high purity silica (Wacker HDK T40 ®), Wacker Chemie AG were used in the study adsorption of the analytes and internal standards as calibrating material for direct analysis of solids. Correlation graphs using excitation potentials, ionization energies and melting point temperatures were used for chosing the best ISs. Exploratory analysis using hierarchical cluster analysis (HCA) and principal component analysis (PCA) were also performed. Optimization of ICP OES was performed in aqueous and slurry samples to establishment figures of merit, such as sensitivity, robustness, selectivity and repeatability. In the optimization of ICP, power supply, nebulizer flow rate and auxiliary gas flow rate were considered. The determination of Ca, Fe, Ga, In, Si and Zn in alumina was made after decomposition in a microwave oven with subsequent precipitation of Al(III) with NH3 gas. The internal standard was essential to obtain the accuracy of the method, with recoveries of CRM analysis ranging from 83 to 117%. For the cement analysis was evaluated the effect of nitric acid concentration over analytes extraction (Al, Ca, Cr, Fe, K, Mg, Mn, Na, P, S, Si, Sr, Ti and Zn) and ISs candidate adsorption (Be, Sc, In and Dy). Determinations of the elements in cement slurry with the internal standard (except for Cr and Zn), with 0.5% v v-1 HNO3, nebulizer Burgener and robust conditions of ICP produced results with recoveries between 68 and 119%. The determinations of Al, Ba, Cr, Fe, K, Li, Mg, Na, Sr and Ti in quartz were performed with the slurry introduction and without of internal standard, using similar conditions of those adopted for cement matrix. In this case the recoveries ranged from 90 to 107% with addition and recovery test. The adsorption of the analytes and internal standards on silica nanoparticles could be an alternative for the preparation of calibration standards when considering performing the direct introduction of solid material.
1522

Resposta dos tecidos periodontais aos cimentos de silicato tricálcico associado ao óxido de zircônio ou óxido de nióbio usados no selamento de perfurações de furca em molares de ratos /

Barbosa, Derik Damasceno. January 2016 (has links)
Orientador: Paulo Sérgio Cerri / Banca: Lea Assed Bezerra da Silva / Banca: Mario Tanomaru Filho / Resumo: Perfurações radiculares acidentais ocorrem em cerca de 2-12% dos dentes tratados endodonticamente. Estas perfurações causam injúria aos tecidos periodontais adjacentes e, frequentemente, promovem a invasão bacteriana culminando com a inflamação do ligamento periodontal e reabsorção óssea podendo levar a perda do elemento dental. Dentre os materiais indicados para o selamento destas perfurações, o MTA tem sido largamente usado. O MTA é basicamente composto por silicatos de cálcio (80%) e óxido de bismuto (Bi2O3; 20%), usado como agente radiopacificador. Silicato tricálcico (STC) é um biomaterial utilizado associado ao óxido de zircônio (ZrO2) e o óxido de nióbio (Nb2O5) é um radiopacificador alternativo. O objetivo deste estudo foi avaliar a resposta dos tecidos periodontais promovida pelo silicato tricálcico puro (Mineral Research Processing, Meyzieu, França) associado ao ZrO2 ou ao Nb2O5 comparando-os ao MTA-Angelus, em perfuração de furca de molares de ratos. Foram utilizados 80 ratos, distribuídos em 4 grupos: GS (sham), STC+ZrO2, STC+Nb2O5 e GMTA, de acordo com o material de selamento. No grupo GS, as perfurações no assoalho da câmara pulpar não foram seladas. O acesso da cavidade foi restaurado com cimento de ionômero de vidro fotopolimerizável. Os 1os molares esquerdos, sem perfurações no assoalho da câmara pulpar, foram usados como controle (GC). Após os períodos de 7, 15, 30 e 60 as maxilas foram removidas, fixadas, descalcificadas e incluídas em parafina. Os cortes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Accidental radicular perforation occurs in about 2-12% of endodontically treated teeth. These perforations lead to injury of periodontal tissues and frequently promote bacterial invasion inducing to periodontal ligament inflammation and bone resorption may lead to tooth loss. Among the materials suitable for the sealing of these perforations, the MTA has been widely used. MTA is basically composed of calcium silicate (80%) and bismuth oxide (Bi2O3, 20%), a radiopacifying agent. Tricalcium silicate (TCS) is a biomaterial used associated with zirconium oxide (ZrO2) and niobium oxide (Nb2O5) is an alternative radiopacifier. Our purpose was to evaluate response of the periodontium adjacent to furcation perforations in rat molars filled with pure tricalcium silicate (Mineral Research Processing, Meyzieu, France) associated with ZrO2 or Nb2O5 and MTA-Angelus. Eighty rats were distributed into four groups: SG (sham), TCS+ZrO2, TCS+Nb2O5 and MTAG according to the sealing material. In the SG group, the perforations in the pulp chamber floors were not sealed. The access cavity was restored with light-cure glass-ionomer cement. The left upper first molars, without perforations in the pulp chamber floors, were used as controls (CG). After 7, 15, 30 and 60 days, fragments of maxilla were fixed, decalcified and embedded in paraffin. In the HE-stained sections, the volume density of inflammatory cells (VvIC), fibroblasts (VvFb) and blood vessels (VvBV) was obtained. The width of the periodo... (Complete abstract click electronic access below) / Mestre
1523

Modélisation des transferts hydriques dans les milieux poreux partiellement saturés par homogénéisation périodique : Application aux matériaux cimentaires / Modeling moisture transfer in unsaturated porous media by periodic homogenization : Application to cementitious materials

Mchirgui, Walid 10 May 2012 (has links)
L'objectif de ce travail est d'obtenir, par homogénéisation périodique, des modèles macroscopiques de transfert hydrique dans les milieux poreux partiellement saturés à partir des équations de transfert de l'eau liquide et de vapeur d'eau écrites à une échelle microscopique. La dimensionnalisation des équations fait apparaître naturellement des nombres sans dimension caractérisant les problèmes de transfert hydriques dans les milieux partiellement saturés. Nous nous sommes intéressés à trois différents régimes de transfert (diffusion de vapeur prédominante, couplage diffusion/convection, convection de l'eau liquide prédominante). Pour chaque modèle homogénéisé, nous avons obtenu une expression différente du tenseur de diffusion hydrique homogénéisé. Nous avons ensuite calculé les tenseurs de diffusion hydrique homogénéisés obtenus dans les deux régions hygroscopique et super-hygroscopique, sur des géométries plus ou moins complexes décrivant la microstructure en 2D et 3D. Des comparaisons avec des valeurs expérimentales ont été ensuite effectuées. Pour finir, une résolution numérique de l'équation de transfert hydrique macroscopique homogénéisée a été effectuée en se basant sur les données expérimentales d'un béton BHP. / We propose in this work to construct, by periodic homogenization, macroscopic models of moisture transfer in unsaturated porous media. To do this, the liquid water and water vapor transport equations are averaged from the microscopic scale. The dimensional analysis of transport equations naturally lets appear dimensionless numbers characterizing the moisture transfer in unsaturated porous media. Three different transfer regimes are addressed (predominant water vapor diffusion, coupling diffusion / convection, predominant liquid water convection). For each transfer regime, the associated homogenized moisture diffusion tensor has a different expression. Then, the homogenized moisture diffusion tensors are calculated in both hygroscopic and super-hygroscopic regions on several geometries with varying complexity, describing 2D and 3D microstructures. Comparisons with experimental values are also addressed. Finally, based on experimental data of a BHP concrete, a numerical resolution of the homogenized macroscopic moisture transfer equation is performed.
1524

Béton à base de recyclats : influence du type de recyclats et rôle de la formulation / Concrete with waste aggregates : effect of aggregates type and role of composition

Serifou, Mamery 23 December 2013 (has links)
L‟élimination de certains déchets est un enjeu important en Côte d‟Ivoire. Une des solutions proposée est d‟envisager l‟utilisation de ces déchets comme granulats dans les bétons. Les travaux présentés dans ce document portent sur l‟incorporation de quatre différents déchets.La première étude porte sur un béton confectionné avec trois types de déchets : du verre concassé, du ciment durci concassé et des pneus découpés. Elle a été réalisée en deux phases. Dans la première ces déchets ont été incorporés à du béton pour remplacer 100% des graviers (substitution totale). Dans la seconde une substitution (massique) partielle de gravier a été réalisée dans les proportions suivantes 5, 10, 15, 20, 25 et 30 %, la matrice mortier et le rapport eau-ciment restant identiques. Après une maturation de 28 jours leurs résistances en compression ont été déterminées. Ces résultats montrent que les bétons de recyclât ont une résistance inférieure à celui des bétons de concassé de gravier. Toutefois, la résistance mécanique baisse avec l‟augmentation de la substitution. Une loi donnant la résistance en fonction du taux de recyclât a été établie. De plus, la spécificité des granulats de caoutchouc (résistance à la fissuration) est remarquée.Par ailleurs, les résistances des bétons de recyclât ont permis d‟établir une loi donnant la résistance en fonction des caractéristiques des agrégats et de leur fraction volumique. Une modélisation analytique a été proposée pour prédire la résistance des bétons en fonction de la taille et du volume des granulats recyclés.Les granulats issus du concassage des bétons frais (retour de toupie) utilisés comme substituant des granulats naturels a été menée pour évaluer leur potentiel. Un plan d‟expériences statistique à deux variables (% de recyclât dans le sable et % de recyclât dans le gravier) a été utilisé pour réduire le nombre de mesures. Les proportions de remplacement utilisées sont : 0%, 50% et 100%. Les propriétés mécaniques ont été déterminées par différentes méthodes destructives (résistance à la compression et à la traction) et non destructives (ondes ultrasonores pour évaluer l‟élasticité du matériau). De même, les propriétés physiques telles que la porosité accessible à l‟eau, la masse volumique ont été mesurées. Ces résultats montrent une bonne corrélation entre le pourcentage de remplacement et les propriétés physiques et mécaniques de ce béton / Waste management is an important issue for Côte d‟Ivoire. Among many possibilities, recycling wastes as aggregates for concrete is a solution that deserves to be evaluated. In this study four recycled aggregates are tested: crushed glass, tire cut rubber, hardened cement and fresh concrete waste. There properties are compared to those of natural aggregates.A first study is realized in Côte d‟Ivoire on glass, rubber and hardened cement. Concrete is realized and tested in compression (cylindrical 16x32 specimens). A mix with an increasing quantity of coarse aggregates is tested for each recycled material (20 %, 25 %, 30 % and 50 % in mass of fine and coarse aggregates). It is shown that the strength decreases with the replacement rate and that the decrease depends on the replacing material. The materials ranged in the following increasing order: rubber, glass, hardened cement and natural aggregates. A power law is established which gives the compressive strength as function of the mix and the materials characteristics. Analytical modeling was proposed for predincting the strength with respect to recycled aggregates size and volume.Another experiment is also made on glass and rubber, where partial replacement in increasing percentage is tested. Natural aggregates are partially replaced in the mix with the ranges of 5, 10, 20, 25 and 30 % by rubber and glass. The compressive strength is determined and a decrease is observed for the two materials. In the case of rubber a high decrease in observe with the replacement. In the case of glass a decrease occurs between 0 and 5 % replacement then the strength remains constant with the replacement rate. The third experiment is made with partial replacement of fresh recycled concrete (excess of ready-mixed concrete from concrete mixing plant which is hardened and then crushed). A plan of experiments is made which allows a polynomial law to be drawn giving the strength as a function of the recycled proportion. Other properties (Young modulus, P wave velocity, porosity, density, etc) have been determined and their relation with replacement rate computed.
1525

O USO DO VIDRO RECICLADO COMO PRECURSOR DE SISTEMAS CIMENTANTES GEOPOLIMÉRICOS

Lima Junior, Luiz Cezar Miranda de 29 August 2016 (has links)
Made available in DSpace on 2017-07-21T20:43:50Z (GMT). No. of bitstreams: 1 Luiz Cezar Lima Junior.pdf: 4959123 bytes, checksum: 8ba169401ed3c8565f7d14d0d74e19c1 (MD5) Previous issue date: 2016-08-29 / Geopolymers, or ‘inorganic polymers’, considered an alternative cementing system to the convention Portland cement, are formed due to the dissolution, under a high alkali solution, of natural raw materials containing aluminosilicate species. The product of this reaction is the obtainment of a synthetic aluminosilicate product, manufactured under low temperature or even at room temperature. A wide range of materials can be used as precursors as well as alkali activators. The present work focuses on the obtainment of inorganic polymers with innovative precursors, based on different residues of several industrial sectors, such as glass manufacturing, ceramic claddings, and also with local minerals found in abundance on the region of the Campos Gerais. The development of an alternative cementing system will be directly applied on materials to be used as external cladding of steel/wood-based modular structures for residential/commercial buildings, replacing similar materials made from ordinary Portland cement, aiming and industrial application for this product. The obtained product presented similar/superior physical-mechanical properties when compared to its opponent products, with an average flexural strength of 11,73 MPa and a water absorption of 13,50%, being the first value intermediate and the second the best in comparison with commercial products. The use of temperature during curing cycle for increasing the properties of the geopolymeric cement was successfully tested, resulting on more dense and stable structures. Samples showed an increase in flexural strength from 1,83 MPa to 10,15MPa comparing curing cycles at room temperature and at 65ºC, which indicates that temperature works as a setting accelerator for the tested recipe of geopolymers. / Geopolímeros, ou ‘polímeros inorgânicos’, considerados um sistema cimentante alternativo ao cimento Portland convencional, são materiais formados a partir da dissolução de matérias-primas naturais à base de aluminossilicatos em uma solução alcalina. O resultado desta reação é a formação de um aluminossilicato sintético, produzido a baixas temperaturas ou mesmo sob temperatura ambiente. Diferentes matérias-primas naturais e sintéticas podem ser utilizadas como precursores e fonte de álcalis. O presente trabalho tem por objetivo o desenvolvimento de polímeros inorgânicos a partir de precursores inovadores, utilizando-se de resíduos de diversos setores da indústria, tais como da fabricação de vidro, da indústria de revestimentos cerâmicos, e também de insumos locais disponíveis em abundância na região dos Campos Gerais. O sistema cimentante obtido foi utilizado para a obtenção de placas de revestimento em construções em estrutura modular de aço ou madeira, substituindo produtos similares produzidos a partir de cimento Portland convencional, e visando uma aplicação industrial deste. O produto obtido apresentou propriedades físico-mecânicas semelhantes e até superiores às dos produtos concorrentes, com uma resistência à flexão média de 11,73 MPa e uma absorção de umidade média de 13,50%, sendo o primeiro valor intermediário e o segundo o melhor dentre os produtos comerciais. O uso de temperatura para aumento das propriedades físico-mecânicas do cimento geopolimérico foi testado com sucesso, resultando em estruturas mais compactas e estáveis. Houve um aumento de resistência mecânica de 1,83 MPa para 10,15 MPa comparando-se ciclos de cura sob temperatura ambiente e a 65ºC, indicando que a temperatura funciona como um acelerador de cura dos geopolímeros testados.
1526

EFEITO DE CIMENTOS ENDODÔNTICOS NA RESISTÊNCIA DE UNIÃO DE PINOS DE FIBRA DE VIDRO À DENTINA RADICULAR / Effect of endodontic sealers on the bond strength of glass fiber posts to root dentin

Ruiz, Lucas Manuel 27 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:21Z (GMT). No. of bitstreams: 1 lucas m ruiz.pdf: 809225 bytes, checksum: 4f9a5e3d41d46a1259de31458f886bd4 (MD5) Previous issue date: 2012-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to evaluate the influence of root canal sealers on the bond strength (BS) of glass fiber posts to root dentin using two cementation systems, two storage periods and the different root regions. It was used 56 human teeth,healthy canines, transversely sectioned immediately after the cement-enamel junction. Then the roots were divided into two groups (n = 28) according to the sealer (with or without eugenol [Endofill and Sealer 26, respectively]). Subsequently, the roots were subdivided into two subgroups each (n = 14) according to the period of storage before the adhesive cementation, 7 and 180 days. Each subgroup was further again subdivided according to the resin cement to be used, being a conventional dual resin cement (Variolink® II ) and a dual adhesive system (Excite DSC), and the other a dual resin cement autoconditioning and self-adhesive (RelyX™ U100). The glass fiber posts (White Post DC) were cemented according to manufacturer's instructions for each cementation system. All roots were stored for one week after adhesive cementation, and were subsequently sectioned transversely into six discs about 1 mm thick each, and the coronal (CT), middle (MT) and apical (AT) thirds of the root canal identified. The push-out test was carried out at a crosshead speed of 0.5 mm/min. The data were statistically analyzed by ANOVA factorial and post-hoc Tukey`s test (p=0.05). The analysis of variance showed a statistically significant effect for the factors time (F=6.58, p=0.01) and root third (F=26.67, p=0.0005). The specimens that received intra-canal posts 6 months after the endodontic treatment had higher BS than the specimens treated 7 days after endodontic treatment. The AT showed statistically lower BS than those of CT and MT. It can be concluded that the bond strength of fiber posts to root dentin was not affected by the root canal sealers and cementation systems. / O propósito deste estudo foi avaliar a influência dos cimentos endodônticos na resistência de união (RU) de pinos de fibra de vidro à dentina radicular, utilizando dois sistemas de cimentação, dois períodos de armazenamento e as diferentes regiões radiculares. Foram utilizados 56 dentes humanos, caninos hígidos, seccionados transversalmente imediatamente após a junção cemento-esmalte. Em seguida, as raízes foram divididas em dois grupos (n=28) de acordo com o cimento endodôntico (com ou sem eugenol [Endofill e Sealer 26, respectivamente]).Posteriormente, as raízes foram subdivididas em dois subgrupos cada (n=14) de acordo com o período de armazenamento antes da cimentação adesiva, sendo 7 e 180 dias. Cada subgrupo foi novamente subdividido de acordo com o cimento resinoso a ser utilizado sendo um cimento resinoso convencional dual (Variolink II) e sistema adesivo dual (Excite DSC), e outro cimento resinoso dual auto condicionante e auto adesivo (RelyX U100). Os pinos de fibra de vidro (White Post DC) foram cimentados de acordo com as instruções do fabricante de cada sistema de cimentação. Todas as raízes foram armazenadas por uma semana após a cimentação adesiva, e posteriormente seccionadas transversalmente em seis discos de aproximadamente 1 mm de espessura cada, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular foram identificados. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA fatorial e pós teste de Tukey (p=0,05). A análise de variância demonstrou um efeito estatisticamente significante para os fatores tempo (F=6,58; p=0,01) e terço radicular (F=26,67; p=0,0005). Os espécimes que receberam pino intra-canal após 6 meses do tratamento endodôntico apresentaram maior RU do que os espécimes tratados após 7 dias do tratamento endodôntico. O TA demonstrou valores de RU estatisticamente inferiores às dos TC e TM. Pode-se concluir que a resistência de união dos pinos de fibra à dentina radicular não foi afetada pelos cimentos endodônticos e sistemas de cimentação.
1527

POTENCIAL EROSIVO DE BEBIDAS INDUSTRIALIZADAS DE LARANJA SOBRE O ESMALTE DECÍDUO E CIMENTOS IONOMÉRICOS (IN VITRO) / Erosive potential of industrial orange beverage in deciduous enamel and glass ionomer cements (in vitro)

Gregol, Luísa Rech Gomes 28 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1 Luisa Gregol.pdf: 2797827 bytes, checksum: 470916da6ea25b54a043550107a058df (MD5) Previous issue date: 2012-02-28 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The study in vitro aims to determine the erosive potential of industrialized beverages orange on deciduous enamel, glass ionomer cement with high viscosity - Ketac Molar EasyMixTM - (GIC) and glass ionomer cement modified by resin - VitremerTM - (CIVMR),by changing the hardness and surface roughness. Were prepared 60 samples of each surface divided into six groups: control, C5 and C15, orange drink with soy,S5 and S15, and orange drink, L5 and L15. For five days every group suffered erosive challenge (immersion - 6h storage - immersion - 6h storage - immersion - 12 hours of storage) and immersion time ranged from 5 to 15 minutes. The initial surface microhardness (ISM) and final (FSM) was measured using a microhardness, calibrated to make indentations with a load of 50g/5s tipped endentadora Knoop, five indentations were made by CP. The initial surface roughness (ISR) and final (FSR) was measured using a roughness of contact, five readings were made by sample.The difference in values of microhardness (FSM - ISM) between the groups was significant (p <0.05 - Student's t) for all groups IVC, the IVC-MR this difference was not significant (p> 0.05) S5 in the treatment, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15. The difference in roughness values (FSR - ISR) between groups was significant (p <0.05 - Student's t) for all the CIV-MR groups, the MIC for this difference was not significant (p> 0.05) C5 group, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15.Concluding that both industrialized beverages tested are orange erosive deciduous enamel and glass ionomer cements and that in times of five and fifteen minutes of soaking the change of surface microhardness and surface roughness was similar between groups. / Este estudo, in vitro, tem por objetivo determinar o potencial erosivo de bebidas industrializadas de laranja sobre o esmalte decíduo, cimento de ionômero de vidro de alta viscosidade – Ketac Molar EasyMixTM - (CIV) e cimento de ionômero de vidro modificado por resina - VitremerTM - (CIV-MR), através da alteração da microdureza e rugosidade superficial. Foram confeccionados 60 corpos de prova de cada superfície divididos em seis grupos: controle, C5 e C15, bebida de laranja com soja, S5 e S15, e bebida de laranja, L5 e L15. Durante cinco dias todos os grupos sofreram desafio erosivo (imersão – 6h de armazenamento – imersão – 6h de armazenamento – imersão – 12h de armazenamento) e o tempo de imersão variou entre 5 e 15 minutos. A microdureza superficial inicial (MSI) e final (MSF) foi verificada com microdurômetro, calibrado para realizar endentações com uma carga de 50g/5s com ponta endentadora Knoop, foram realizadas cinco endentações por CP. A rugosidade superficial inicial (RSI) e final (RSF) foi verificada utilizando-se um rugosímetro de contato, foram realizadas cinco leituras por CP. A diferença de valores de microdureza superficial (MSF-MSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV, o CIV-MR esta diferença não foi significativa (p>0,05) no tratamento S5, e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. A diferença dos valores de rugosidade (RSF – RSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV-MR, para o CIV esta diferença não foi significativa (p>0,05) no grupo C5,e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. Concluindo-se que as duas bebidas industrializadas de laranja testadas são erosivas ao esmalte decíduo e aos cimentos de ionômero vidro e que nos tempos de cinco e quinze minutos de imersão a alteração de microdureza superficial e de rugosidade superficial foi semelhante entre os grupos.
1528

O EFEITO DO SISTEMA DE CIMENTAÇÃO ADESIVA E TEMPO DE ARMAZENAMENTO NOS VALORES DE RESISTÊNCIA DE UNIÃO, NANODUREZA E MÓDULO DE ELASTICIDADE NO AMBIENTE INTRA-RADICULAR

Higashi, Cristian 07 December 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1 CRISTIAN HIGASHI.pdf: 3013347 bytes, checksum: 87da650524fbc43c80566136e07331cd (MD5) Previous issue date: 2012-12-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the push-out bond strength, nanohardness and Young’s modulus of three resin cements used for luting fiber post. The measurements were taken at cervical (CT), middle (MT) and apical (AT) radicular thirds, at immediate time and after one year of storage in water. Root canals of 57 human teeth were endodontically treated and prepared to cementation of fiber post (White Post DC - FGM) using the cementation systems: Multilink [MUL] (Ivoclar Vivadent), Variolink II + Excite DSC [VAR] (Ivoclar Vivadent) and R RelyXTM Unicem [UNC] (3M ESPE). For the push-out test (n=16), after 24hs of water storage at 37ºC, half the sample (n=8) was transversely sectioned into 6 slices, being 2 slices for each radicular third, which were assess d at 0,5 mm/min. The remaining half (N=8) was kept unsectioned in deionized water at 37ºC for 1 year, followed by sectioning and measuring. For the nanoindentation test, the cemented samples (n=3) were stored in water at 37ºC for 24hs and after were longitudinally sectioned to perform the initial measurements of hardness and elastic’s modulus from cervical to apex. These same samples were stored in deionized water at 37ºC for 1 year and reassessed. The data were analyzed by three-way ANOVA and Tukey’s test (α=0.05). The mean and standard deviation of MUL bond strength (MPa) in AT (19.9 ± 3.9) was higher than MT (15.1 ± 4.7) and CT (14.9 ± 4.2) (p=0.00007). The immediate bond strength of AT (22.0 ± 4.9) decreased significantly after 1 year of water storage (15.1 ±4.1) (p=0.006). The MUL cement obtained higher values of Young’s modulus (GPa) in CT (9.2 ± 1.9) when compared to MT (6.6 ± 2.0) e AT (5.4 ± 2.6)(p=0.01). The AT has the lowest values of hardness (GPa) (0.40 ± 0.10) when compared to MT (0.45 ± 0.12) and CT (0.48 ± 0.11) (p=0.000001). The initial hardness of UNC cement (0.43 ± 0.12) decreased after 1 year of storage in water (0.35 ± 0.14) (p=0.0051). It was concluded that: 1) The bond strength of MUL cement was higher in AT, 2) The AT of the cements suffered higher bond degradation after 1 year of storage water, 3) The Young’s modulus of MUL cement was higher in CT, 4) The AT of all cements had lowest hardness values, 5) After 1 year of storage in water, the UNC cement had a significant decreased of hardness values. / O objetivo deste trabalho foi avaliar a resistência de união, nanodureza e módulo de elasticidade de 3 cimentos resinosos utilizados para cimentar pinos de fibra de vidro. As mensurações foram feitas nos terços cervical [TC], médio [TM] e apical [TA] das raízes, no tempo imediato e após 1 ano de armazenamento em água destilada. Os canais radiculares de 57 dentes humanos unirradiculares foram tratados endodonticamente e preparados para a cimentação dos pinos de fibra de vidro White Post DC (FGM) utilizando os sistemas de cimentação Multilink [MUL] (Ivoclar Vivadent), Variolink II + Excite DSC [VAR] (Ivoclar Vivadent) e RelyXTM Unicem [UNC] (3M ESPE). Para o teste de push-out (n=16), após 24hs de armazenamento em água destilada à 37ºC, metade das amostras (n=8) foram cortadas transversalmente em 6 fatias, sendo 2 fatias para cada terço radicular, que foram testadas à velocidade de 0,5 mm/min. A outra metade das amostras cimentadas (n=8) foram mantidas íntegras em água destilada à 37ºC por 1 ano, seguidos pelos cortes e mensurações. Para o teste de nanoindentação, as amostras cimentadas (n=3) foram armazenadas em água à 37ºC por 24hs e logo após, cortadas longitudinalmente aos seus longos eixos para a realização das mensurações iniciais de nanodureza e módulo de elasticidade do TC até TA. Estas mesmas amostras foram armazenadas em água destilada à 37ºC por 1 ano e retestadas. Os dados foram submetidos a uma análise de variância de três critérios e ao teste de Tukey (α=0,05). A média e desvio padrão dos valores de resistência de união (MPa) do cimento MUL no TA (19,9 ± 3,9) foi maior do que no TM (15,1 ± 4,7) e TC (14,9 ± 4,2) (p=0,00007). A resistência de união imediata do TA (22,0 ± 4,9) diminuiu significativamente após 1 ano de armazenamento em água (15,1 ± 4,1) (p=0,006). O cimento MUL obteve maiores valores de módulo de elasticidade (GPa) no TC (9,2 ± 1,9) em compara ão ao TM (6,6 ± 2,0) e TA (5,4 ± 2,6) (p=0,01). O TA radicular teve os menores valores de nanodureza (GPa)(0,40 ± 0,10) quando comparado com os TM (0,45 ± 0,12) e TC (0,48 ± 0,11) (p=0,000001). A nanodureza inicial do cimento UNC (0,43 ± 0,12) diminui após 1 ano de armazenamento em água (0,35 ± 0,14) (p=0,0051). Concluiuse que: 1) A resistência do cimento MUL foi maior no TA; 2) O TA dos cimentos sofreu uma maior degradação da união após o armazenamento de 1 ano em água; 3) O módulo de elasticidade do cimento MUL foi maior no TC; 4) O TA de todos os cimentos teve menores valores de dureza; 5) O cimento UNC teve uma diminuição significativa dos valores de nanodureza após 1 ano de ar azenamento em água. Palavras-chave: Cimento resinoso. Pino de fibra. Dentina radicular.
1529

Logística reversa para substituição de combustíveis na indústria cimenteira por coprocessamento em forno de clinquer

Junior, Nelson Kadel January 2012 (has links)
Submitted by William Justo Figueiro (williamjf) on 2015-07-10T22:43:09Z No. of bitstreams: 1 42b.pdf: 11938841 bytes, checksum: 548f5c4ae8b13931af52bc417ff2da4f (MD5) / Made available in DSpace on 2015-07-10T22:43:09Z (GMT). No. of bitstreams: 1 42b.pdf: 11938841 bytes, checksum: 548f5c4ae8b13931af52bc417ff2da4f (MD5) Previous issue date: 2012 / Nenhuma / O objetivo desta dissertação de mestrado é estudar um projeto de coprocessamento de resíduos, e desenvolver um meio de torná-lo sustentável economicamente, à luz das teorias sobre logística reversa. Este projeto traz consigo resultados que vão além da área financeira, ao utilizar, da melhor forma, as cadeias logísticas já existentes na região, reduzindo, assim, o seu impacto na natureza. Uma vez que este projeto foi identificado ainda na sua fase de desenvolvimento, o método de pesquisa utilizado foi a pesquisa-ação. Neste tipo de método, usam-se as teorias existentes para planejar as intervenções de campo, ao mesmo tempo que se aproveitam os resultados para gerar avanços teóricos. Os objetivos específicos deste trabalho buscam estudar, primeiramente, as empresas fornecedoras de resíduos, analisando as suas localizações, bem como os tipos de produtos disponibilizados. A partir daí, ver o melhor lugar para instalar a planta produtora de mistura (blend), levando em consideração as restrições ambientais, os custos envolvidos e a oferta de modais de transporte, e por fim, analisar as empresas cimenteiras consumidoras de tal mistura. Os resultados mais importantes estão relacionados à mudança de localização da planta de coprocessamento, ao processo logístico de coleta dos resíduos bem como do produto final e o desenvolvimento de uma embalagem para o seu transporte. As implicações finais são ambientais, financeiras e estratégicas. Este projeto viabiliza o uso de uma parte significativa de resíduos que antes teriam como destino, na melhor das opções, os aterros sanitários da região, e agora passam ser uteis como combustíveis em uma nova cadeia de produção. Já os resultados econômicos atingiram as duas principais empresas estudas. Para a primeira, houve uma redução de 27% no custo logístico dos produtos produzidos. Já para a segunda, 8% no custo de combustível utilizado em fornos. Por fim, as estratégicas garantem, para a unidade de blendagem, um diferencial perante possíveis novos entrantes no mercado. Para garantir tudo isso, esta pesquisa passa pelos conceitos de logística e logística reversa, fazendo um apanhado sobre a produção de cimento e relatando os combustíveis utilizados nestas plantas, com as suas futuras opções de substituição, uma vez que este é um tipo de indústria altamente demandante de energia e calor. Finalmente, o caso analisado é a primeira planta de coprocessamento do Rio Grande do Sul que fará uso de diversos tipos de resíduos na confecção de um combustível alternativo para fornos de clinquer. / This dissertation aims to study a waste co-processing, and develop a way to make it economically sustainable within the logistic and reverse logistics theory. This brings together results that go beyond the financial area, when the logistics chains in the region are used at best in order to reduce the impact on the environment. Once this research project has already been identified in its development phase, the method of research is action-research. In this type of method, they use existing theories to plan interventions in the field, while the results take advantage to generate theorist advancements. The specific aims of this paper target the study, firstly, of the waste suppliers, analyzing their locations as well as the kinds of available products. From this point of view, we can see the best place to install the production blend plant, taking into consideration the environmental restrictions, the costs and the offering of different types of transport, and finally it analyzes the cement consumer companies of such blend. The most important results are related to the changing of the co-processing plant location, the logistic process of waste collection as well as the final product and the development of a kind of suitable wrapping for its transport. The final consequences are environmental, financial and strategic. This project enables the use of a significant portion of waste that would previously have as destination, at best, the region's landfills, and are now being useful as fuels in a new production chain. Since the economic results achieved two major companies studied. For the first, there was a 27% reduction in logistics costs of products produced. As for the second, 8% of the cost of fuel. Finally, the strategic guarantee, for the blending unit, a differential to possible new entrants in the market. So, this study analyses the concepts on logistics and reverse-logistics, making an overview on the cement production and the different kinds of fuel used in these plants, with its future replacement options - once this is a type of industry that demands high amounts of energy and heating. Finally, the case study talks about the first co-processing plant in Rio Grande do Sul, which is going to use several sorts of waste in the manufacturing of an alternative kind of fuel for clinker kilns.
1530

Determinação instantânea da relação água-cimento e da resistência à compressão do concreto no estado fresco através do método da resistividade elétrica

Braun, Carlos Eduardo 07 April 2015 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-02-15T14:12:54Z No. of bitstreams: 1 Carlos Eduardo Braun_.pdf: 3816402 bytes, checksum: 868ecc968577b70b35d2cfde265248ec (MD5) / Made available in DSpace on 2016-02-15T14:12:54Z (GMT). No. of bitstreams: 1 Carlos Eduardo Braun_.pdf: 3816402 bytes, checksum: 868ecc968577b70b35d2cfde265248ec (MD5) Previous issue date: 2015-04-07 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / Durante a execução de elementos de concreto no canteiro de obras, procedimentos de controle de qualidade do concreto são adotados com o objetivo de verificar se o material atende às características de projeto. Esta verificação também visa evitar falhas durante as etapas subsequentes da construção, que podem levar até à inviabilização do empreendimento. Estudos sobre métodos que têm como objetivo estimar a relação água/cimento (a/c) do concreto no estado fresco vêm recebendo maior atenção nos últimos tempos, devido à importância deste parâmetro sobre a resistência e durabilidade das estruturas de concreto, e por não existirem métodos práticos e precisos disponíveis até o momento, que permitam a sua determinação após a realização da mistura. Estudos sobre o método da resistividade elétrica apontam para uma forte correlação entre os valores de resistividade e a relação água/cimento do concreto no estado fresco, possibilitando a utilização do método como uma interessante alternativa para determinação da relação a/c. O presente estudo tem como objetivo apresentar uma análise do método da resistividade elétrica, aplicado à estimativa de valores de relação água/cimento de concretos no estado fresco, confeccionados com cimentos nacionais, além da estimativa de valores de resistência à compressão axial do concreto no estado endurecido. Foram realizados ensaios com concretos dosados a partir do método IPT/EPUSP para seis cimentos nacionais (CPV-ARI, CPIV-32, CPIII-40, CPII-Z-32, CPII-F-32 e CPII-E-40), variando-se a relação a/c (0,35, 0,45, 0,55 e 0,65), utilizando uma sonda aprimorada para realização dos testes, a qual foi desenvolvida neste estudo com base num protótipo já desenvolvido anteriormente. Os resultados obtidos apontam para uma forte correlação existente entre a resistividade elétrica do concreto no estado fresco e a relação a/c, com valores médios das estimativas para relação a/c dentro do intervalo de ±0,02, com relação aos valores efetivos das misturas testadas. A margem de erro média para as estimativas de relação a/c, considerando-se todos os cimentos testados, ficou no intervalo entre 2,25% e 9,38%. Foram obtidos coeficientes de determinação na ordem de 85,7% a 95,2% para as estimativas de resistência à compressão, mostrando que é possível determinar tanto a relação a/c quanto a resistência à compressão do concreto através do método da resistividade elétrica, quando o material encontra-se ainda no estado fresco. / During construction of concrete elements in the building site, quality control proceedings are adopted in order to verify if the concrete reaches its design specifications, which also avoids failures during the subsequent stages of the construction. Test methods used for the determination of the water-cement (w/c) ratio have received increased attention, due to the importance of this ratio for the concrete resistance and durability, and also because there isn’t any practical and sufficiently precise method available at the moment, which could be used for determining water-cement ration after mixing. Studies about the electrical resistivity method have shown a strong relationship between the measured resistivity values and water-cement ratio, for the fresh concrete, making this method an interesting alternative for determining w/c ratio. This study presents an analysis of the electrical resistivity method, applied to determine the water-cement ratio of several fresh concrete mixtures made with different types of Brazilian cements, in addition to estimates of compressive strength values of the hardened concretes. Concrete mixtures were made out of six cement types (CPV-ARI, CPIV-32, CPIII-40, CPII-Z-32, CPII-F-32 and CPII-E-40), dosed by the IPT/EPUSP method, and four water-cement ratios (0.35, 0.45, 0.55 and 0.65). Tests were performed using an improved probe, developed in this study, based in one prototype developed previously. Results shown a strong relationship between the electrical resistivity of fresh concrete and its water-cement ratio, with average estimated values within ±0,02 of the actual water-cement ratio values for the mixtures tested. The average error for the w/c ratio estimated values, considering all of the cements tested, was between 2,25% and 9,38%. The compressive strength estimates reached coefficients of determination between 85,7% and 95,2%, showing that it is possible to estimate both w/c ratio and compressive strength of concrete while still in the fresh state with the electrical resistivity method presented here.

Page generated in 0.0557 seconds