• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 632
  • 582
  • 114
  • 89
  • 71
  • 36
  • 36
  • 36
  • 35
  • 28
  • 20
  • 15
  • 11
  • 8
  • 8
  • Tagged with
  • 2258
  • 356
  • 343
  • 242
  • 177
  • 172
  • 157
  • 151
  • 150
  • 148
  • 146
  • 144
  • 144
  • 139
  • 137
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1061

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana /

Barca, Diana Capelli. January 2010 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Henrique Cerveira Netto / Banca: Rodrigo Othavio de Assunção e Souza / Resumo: Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling / Mestre
1062

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa /

Yamamoto, Eron Toshio Colauto. January 2011 (has links)
Resumo: O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / Abstract: The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn't influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution / Orientador: Clóvis Pagani / Coorientador: Eduardo Galera da Silva / Banca: Eduardo Shigueyuki Uemura / Banca: Rubens Corte Real de Carvalho / Banca: Pedro Yoshito Noritomi / Banca: Daniel Maranha da Rocha / Doutor
1063

Efeito de diferentes espessuras, técnicas de aplicação e protocolos de resfriamento na resistência à fratura da cerâmica de cobertura aplicada sobre infraestrutura de y-tzp /

Lima, Júlia Magalhães da Costa. January 2014 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Francisco César / Banca: Susana Salazar Marocho / Banca: Renata Marques de Melo / Banca: Alexandre Luiz Souto Borges / Resumo: O objetivo desta pesquisa foi avaliar, in vitro, a influência do resfriamento, da técnica de aplicação e do efeito da espessura da cerâmica de cobertura na carga de fratura de coroas totalmente cerâmicas com infraestrutura de zircônia. Foram confeccionadas 100 infraestruturas de zircônia (Y-TZP) com 1,0 mm de espessura. 80 infraestruturas foram divididas em 8 grupos (n = 10) para confecção de 80 coroas de acordo com os fatores "técnica de aplicação" (estratificada e prensada), "espessura" (1 mm e 2 mm) e "protocolo de resfriamento" (lento e rápido) da cerâmica de cobertura. Com as outras 20 infraestruturas foram confeccionadas 20 coroas pela técnica CAD/CAM/Rapid Layer e divididas em 2 grupos (n = 10) de acordo com o fator "espessura da cerâmica de cobertura" (1 mm e 2 mm) e foi realizada Análise de Elementos Finitos. Todos os espécimes foram ciclados mecanicamente (200 N; 2 x 106 ciclos; 3,0 Hz; água/ 37 °C). A presença de chipping foi avaliada através de análise em estereomicroscópio após a ciclagem mecânica. Em seguida, todos os espécimes foram submetidos ao teste de resistência à fratura em compressão axial (0,5 mm/minuto; 10 kN). As coroas foram analisadas para determinar a possível origem da falha. Os dados (N) obtidos foram submetidos à análise estatística, com o Teste de Dunnett, teste t-Student, para a técnica CAD/CAM/Rapid Layer, e ANOVA 3-fatores e teste de Tukey para as demais técnicas. A carga de fratura das coroas confeccionadas pela técnica CAD/CAM/Rapid Layer, independente da espessura, foi menor em relação às outras duas técnicas (p < 0,05), mas houve diferença significativa entre as duas espessuras das coroas confeccionadas por esta técnica. Houve influência dos fatores resfriamento (p = 0,0058) e técnica de aplicação (p = 0,0001) na análise das técnicas estratificada e prensada. O resfriamento lento diferiu.... / Abstract: The aim of this study was to evaluate the in vitro influence of cooling protocols and application techniques and the effect of the thickness of veneering ceramics on the fracture resistance of prosthetic crowns. For this purpose, 100 'zirconia partially stabilized by yttrium oxide' frameworks (1 mm thick) were made. Eighty frameworks were divided into 8 groups (n = 10) according to the application technique (stratified or pressed), thickness (1 or 2 mm), and the cooling protocol (slow or fast) of the veneering ceramic. With the remaining 20 frameworks, 20 crowns were prepared by the CAD/CAM/Rapid Layer technique and were divided into 2 groups (n = 10) according to the veneering ceramic thickness (1 or 2 mm); these were also evaluated by Finite Element Analysis. All specimens were mechanically cycled (200 N, 2 x 106 cycles; 3.0 Hz; water at 37 °C). Chipping presence was evaluated by stereomicroscopy after mechanical cycling. All specimens were tested for compressive strength (0.5 mm/minute; 10 kN). We analyzed crowns to determine the possible beginning of the failures. Data, in N, were statistically analyzed with Dunnett's, t-test, 3-way ANOVA, and Tukey's tests. The fracture load of the CAD/CAM/Rapid Layer crowns was lower, regardless of ceramic thickness, when compared with the other two application techniques tested (p < 0.05). We observed an influence of the cooling protocol (p = 0.0058) and the application technique (p = 0.0001) in the analysis of stratified and pressed techniques. Slow cooling differed from rapid cooling in the pressed ceramic crowns; however, this difference was not observed for the stratified crowns, regardless of the thickness of the veneering ceramic. Failures in the CAD/CAM/Rapid Layer crowns began predominantly at the interface between the resin cement and veneering ceramic, resulting in delaminations of the veneering ceramic, while the other techniques .... / Doutor
1064

Efeito de protocolos de jateamento na resistência à flexão e transformação de fase cristalina em cerâmicas de Y-TZP /

Turci, Priscilla Cristoforides Pereira. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: João Paulo Barros Machado / Banca: Paulo Francisco César / Banca: Alberto Noriyuki Kojima / Resumo: O objetivo deste estudo foi avaliar o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e transformação de fase cristalina de cerâmica policristalina de Y-TZP. Foram confeccionados 740 discos de zircônia estabilizada parcialmente por ítrio - Cercon®Zirconia (DENTSPLY Ceramco, EUA) e In Ceram 2000 YZ cubes (Vita Zahnfabrik, Alemanha) segundo a norma ISO 6872 (15 mm diâmetro x 2 mm espessura). As amostras foram jateadas com partículas de óxido de alumínio (30 μm) revestido por sílica (RocatecSoft - 3M ESPE) e divididas em 74 grupos (n = 10), incluindo-se os grupos controle (ausência de jateamento)(n = 10) para cada cerâmica, de acordo com os fatores: pressão de jateamento (2, 3 e 4 bar); ângulo formado entre a ponta do jateador e a superfície da cerâmica (45º, 60º, 90º); distância do microjateador à cerâmica (5 e 10 mm) e tempo de jateamento (15 s e 20 s). Foi realizado teste de resistência à flexão biaxial em máquina de ensaio universal (1 mm/min, 1000 kg). Os dados (MPa) foram submetidos a análise de variância e ao teste de Duncan. Parte das amostras (n=3) foram submetidas à difração por raios-X (DRX) para quantificação das fases cristalinas e à microcopia eletrônica de varredura (MEV) para análise da topografia superficial. Pressão (p = 0,00) afetou significativamente os resultados, porém tempo (p = 0,49), distância (p = 0,46) e angulação (p = 0,13) não afetaram a Cercon. Já para Vita YZ, a pressão (p = 0,00) foi estatisticamente significante, porém tempo (p=0,66), distância (p = 0,70) e angulação (p=0,14) não foram. Fase monoclínica foi encontrada nos grupos da Cercon (0 a 11%), enquanto para Vita YZ, nenhuma fase foi encontrada. Para Vita YZ, a pressão 3 bar teve maior resistência à flexão biaxial e 4 bar apresentou menor valor. Angulação de 45° associado a 2 bar foi a melhor combinação (1012,21 ± 108,36 MPa)... / Abstract: The aim of this study was to evaluate the effect of different sandblasting protocols on biaxial flexural strength and crystalline phase transformation in Y - TZP ceramic. 740 discs of Yttria-Partially-Stabilized Zirconia were made - Cercon ® Zirconia (DENTSPLY Ceramco, USA) and In Ceram 2000 YZ cubes (Vita Zahnfabrik, Germany) according to the standards of ISO 6872 (15 mm diameter x 2 mm thick) . The samples were sandblasted with aluminum oxide - coated silica 30 μm (Rocatec Soft - 3M ESPE ) and divided into 74 groups (n = 10 ) , according: pressure (2, 3 and 4 bar) ; nozzle angle (45°, 60°, 90°); nozzle distance (5 and 10 mm) and time (15 s and 20 s) . The biaxial flexural strength on universal testing machine (1mm/min, 1,000 kg) was performed. Data (MPa) were submitted to ANOVA and to Duncan's test (α = 0.05). Samples (n = 2) were subjected to X- ray diffraction to quantify crystalline phases. Pressure (p = 0.00) significantly affected the results, but deposition time (p = 0.49), nozzle distance (p = 0.46) and nozzle angles (p=0.13) did not affect to Cercon ceramic. Pressure (p = 0.00) affected significantly the results to Vita YZ, but deposition time (p = 0.66), nozzle distance (p = 0.70) and nozzle angles (p = 0.14) did not affect. Some monoclinical phase was achieved in Cercon groups (0 a 11%) and none for Vita YZ. For Vita YZ ceramic, 3 bar pressure had the biggest flexural strength value and 4 bar was the worst one and angle 45° associated to 2 bar were the best combination (1012.21 ± 108.36 MPa) compared to 4 bar (556.65 ± 117.41 MPa) (p < 0.001). EDS analysis demonstrated regular superficial grains. SEM images indicated grain size of 0.712 μm (Vita YZ), and 0.705 μm (Cercon). The Cercon density was 98% compared to the theoretical density of zirconia, while VITA YZ was 99% / Doutor
1065

Restaurações cerâmicas minimamente invasivas executadas por cirurgiões dentistas com diferentes níveis de experiência profissional : estudo clínico cego, longitudinal e prospectivo /

Melo, Régis Alexandre da Cunha. January 2015 (has links)
Orientador: Eduardo Passos Rocha / Banca: Paulo Henrique dos Santos / Banca: Rodolfo Bruniera Anchieta / Resumo: Objetivo: Avaliar a influência da experiência profissional de cirurgiões-dentistas na taxa de sobrevida de restaurações cerâmicas delgadas cimentadas sobre dentes anteriores e/ou posteriores. Material e Método: Um total de 16 profissionais em nível de especialização realizaram tratamentos restauradores com cerâmica delgada, que foram divididos em quatro grupos (n=4) de acordo com o tempo de formação profissional - Grupo 1: recém-formados com até 2 anos de formados; Grupo 2: de 2 a 5 anos de formado; Grupo 3: de 5 a 10 anos de formado; Grupo 4: mais de 10 anos de formado. Todos os profissionais foram instruídos e treinados a seguirem o mesmo protocolo clínico de trabalho, embora desconhecessem os objetivos da pesquisa. Um único avaliador acompanhou os atendimentos clínicos realizados em 24 pacientes, totalizando 274 restaurações unitárias em dissilicato de lítio, sendo 158 na região anterior e 116 na posterior, distribuídas entre os arcos maxilar (186) e mandíbular (88). A espessura das cerâmicas variou entre 0,3 mm e 4,0 mm. As intercorrências ocorridas durante a execução dos protocolos clinicos, bem como os tempos de condicionamento ácido, de fotopolimerização e o tipo de cimento foram anotados. As restaurações foram cimentadas com diferentes cimentos em função da espessura da cerâmica, sendo: Rely X U200 (n=120), Rely X Veneer (n=95) e Variolink Veneer (n=58); totalizando 91 coroas totais, 137 facetas com preparo e 46 facetas sem preparo. As avaliações clínicas foram realizadas após a instalação das restaurações e nos controles de 30, 180, 360 dias posteriores à cimentação. Os parâmetros para a avaliação foram baseados nos critérios modificados do USPHS, adaptados ao estudo. Julgou-se insucesso quando houve fratura ou soltura das restaurações. As fraturas foram replicadas e submetidas à análise... / Abstract: Objective: To evaluate if the dentist experience can influence the survival rate of cemented anterior and/or posterior thin ceramic restorations. Materials and Methods: A total of 16 professionals with different expertise level with thin ceramic restorations were divided into four groups (n=4) - Group 1: up to 2 years of the graduation; Group 2: 2 to 5 years of graduation; Group 3: 5-10 years of graduation; Group 4: more than 10 years of graduation. All professionals have been educated and trained to follow the same clinical protocol, but were unaware of the research objectives. A single evaluator accompanied the clinical treatments performed in 24 patients, totaling 274 single restorations in lithium disilicate, 158 in the anterior region and 116 in the posterior distributed region among the arches, 186 in the maxillae and 88 in the jaw. The thickness of the ceramic varied between 0.3 mm and 4.0 mm. Minor complications that occurred during the execution of the protocols, the etching and the light curing times and the type of cement were recorded. The restorations were cemented with different cements according to the thickness of ceramic, which: Rely X U200 (n = 120), Rely X Veneer (n = 95) and Variolink® Veneer (n = 58); totaling 91 full crowns, 137 laminated with preparation and 46 laminated with no prepare. Clinical assessments were performed after the installation of the restorations and at the controls of 30, 180 and 360 days after the cementing period. The parameters for evaluation were based on the modified USPHS criteria, adapted to the study. It was deemed unsuccessful when there was fracture or loosening of the restorations. Fractures were replicated and submitted to fractographic analysis. Results: The least number of failures were observed in Group 2 (1 debonding), the largest number in Group 1 (5 fractures) and highest... / Mestre
1066

Efeito da infiltração de sílica pelo método sol-gel na resistência à flexão de bicamadas de porcelana e Y-TZP /

Reis, Ana Flavia Nunes. January 2015 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Leonardo Buso / Resumo: O objetivo deste trabalho foi infiltrar sílica em uma cerâmica Y-TZP, avaliar seu efeito na resistência à flexão Biaxial, e na união com a porcelana feldspática. Para a análise da resistência à flexão foram confeccionados 180 discos de zircônia, 120 de 0,5mm e 60 com 1,2mm discos (14 mm de diâmetro). 90 discos foram infiltrados com sílica pelo método sol-gel em temperatura ambiente (n = 30). A espessura do disco foi de 1,2 mm para os espécimes controle (espécime sem porcelana, n = 30). O recobrimento por porcelana feldspática foi de duas espessuras (0,5mm e 1 mm) sobre a zircônia que tinha 0,5 mm. Os espécimes com porcelana foram polidos com lixas de carbeto de silício (SiC) de granulação # 400, 600, 800 e 1200. Obtivemos 6 grupos: dois monolíticos (ZR- Zircônia Monolítica sem infiltração e ZRI- Zircônia Monolítica Infiltrada) (controle) e quatro estratificados: ZRF 1,0 (0,5mm Zircônia coberta com 0,5 mm porcelana), ZRIF 1,0 (0,5 mm Zircônia infiltrada coberta com 0,5 mm de porcelana), ZRF 1,5 (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana) ZRIF 1,5- Zircônia infiltrada (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana). Após o ensaio de flexão biaxial em meio aquoso, foram determinados o módulo de Weibull (m) e resistência característica (σθ). Os fragmentos foram analisados em EDS, MEV, DRX e FTIR. A Dureza (H) e tenacidade a fratura foram analisadas pela nanoindentação, já o módulo elástico (E) por duas técnicas, nanoindentação e por impulso, e para avaliar a adesão entre a zircônia e a porcelana foi aplicado o Teste de Scratch. Foram modeladas 7 condições experimentais e analisados pelo método por elementos finitos. A zircônia monolítica infiltrada mostrou uma estrutura com grãos arredondados envoltos em uma matriz de sílica, e a presença de zircônia cúbica e tetragonal. O DRX revelou a formação de ZrSiO4 nos grupos infiltrados. Os grupos monolíticos... / Abstract: The objective was to infiltrate silica in a Y- TZP ceramics, evaluate its effect on resistance biaxial strenght, and the union with feldspathic porcelain. For the analysis of flexural strength were prepared zirconia discs 180, 120 and 60 of 0.5 mm to 1.2 mm disks (14 mm diameter). 90 discs were infiltrated with silica by the sol-gel method at room temperature (n = 30). The thickness of the disk was 1.2 mm for the samples control (no porcelain specimen, n = 30). The coating was feldspathic porcelain by two thicknesses (0.5 mm and 1 mm) of zirconia, which had 0.5 mm. Specimens with porcelain were polished with sandpaper silicon carbide (SiC) granulation # 400, 600, 800 and 1200. We obtained six groups: two monolithic (Zr-Zirconia Monolithic without infiltration and ZRI- Zirconia monolithic Infiltrated) (control) and four laminated ZRF 1.0 (0.5 mm zirconia covered with 0.5 mm porcelain), ZRIF 1.0 (0.5 mm infiltrated zirconia covered with 0.5 mm of porcelain), ZRF 1.5 (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain) ZRIF 1,5-infiltrated Zirconia (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain). After the biaxial bending test in an aqueous medium were determined Weibull modulus (m) and the characteristic strength (σθ). The fragments were analyzed by EDS, SEM, XRD and FTIR. The hardness (H) and fracture toughness were analyzed by nanoindentation, since the elastic modulus (E) by two techniques, nanoindentation and on impulse, and to evaluate the adhesion between the zirconia and porcelain was applied Scratch Test. 7 experimental conditions were modeled and analyzed by the finite element method. The infiltrated zirconia showed a monolithic structure with rounded grain wrapped in a silica matrix, and the presence of cubic and tetragonal zirconia. The XRD showed the formation of ZrSiO4 infiltrates in groups. The monolithic modules Weibull groups showed superior to ... / Mestre
1067

Efeitos de lasers de alta potência na superfície de cerâmicas vítreas de dissilicato de lítio e sua resistência de união à dentina humana /

Feitosa, Fernanda Alves. January 2016 (has links)
Orientador: César Rogério Pucci / Banca: Rebeca Di Nicoló / Banca: Patrícia Moreira de Freitas / Banca: Taís Scaramucci Forlin / Banca: Symone Cristina Teixeira / Resumo:O objetivo desse estudo foi avaliar a eficiência da irradiação com lasers de alta potência e a influência da aplicação do silano previa ou posteriormente à irradiação com os lasers na resistência de união entre cerâmica vítrea de dissilicato de lítio, cimento resinoso e dentina humana. Foram confeccionados 50 espécimes troncocônicos de cerâmica (n=10), divididos aleatoriamente em 5 grupos: 1- ControleCondicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 2- Er:YAG - irradiação com laser Er:YAG (200 mJ e 10 Hz), seguido do condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 3- Silano + Er:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Er:YAG nos mesmo parâmetros do grupo anterior; 4- Nd:YAG - irradiação com laser Nd:YAG (120 mJ e 10 Hz), seguido de condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano, 5- Silano + Nd:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Nd:YAG nos mesmo parâmetros do grupo anterior. Após os tratamentos os espécimes cerâmicos foram cimentados com cimento resinoso de presa dual à superfície de dentina de 50 molares humanos incluídos em resina acrílica ativada quimicamente. Após armazenamento por 24 h foi realizado o ensaio de tração em máquina de ensaios universais com célula de carga de 10 KgF e velocidade constante de 1mm/min. Os dados obtidos foram submetidos à ANOVA 2-fatores e teste de Dunnet (α=5%). A análise dos padrões de fratura foram analisadas em estereomicroscopio. Adicionalmente foram confeccionados 15 espécimes em cerâmica no formato cilíndrico, submetidos aos mesmo tratamentos dos grupos anteriores (n=3) e utilizados para análise do ângulo de contato e análise em microscópio eletrônico de varredura. O teste de Dunnet mostrou diferenças... / Abstract:The aim of this study was to evaluate the efficiency of irradiation with high-power lasers and the influence of silane application before or after irradiation with lasers on the bond strength between lithium disilicate glass-ceramic, resin cement and human dentin. Fifty truncated-cones ceramic specimens (n=10) were randomly divided into 5 groups: Control- etching with hydrofluoric acid 10% for 1 min and application of silane; 2- Er - Er:YAG laser irradiation (200 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of silane; 3- Sil + Er - etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Er: YAG laser in the same parameters as the previous group; 4- Nd:YAG laser - irradiation with Nd: YAG laser (120 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of the silane, 5- Sil + Nd- Etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Nd: YAG laser on the same parameters as the previous group. After treatment, the ceramic specimens were cemented with dual cure resin cement to the dentin of 50 human molars included in acrylic resin. After storage for 24 h it was submitted to tensile test in a universal testing machine with 10 kgf load cell and constant speed of 1 mm/min. Data were submitted to ANOVA 2-way and Dunnet test (α = 5%). The analysis of fracture patterns were analyzed in stereomicroscope. In addition were made 15 ceramic specimens in cylindrical shape, subjected to the same treatment of the above groups (n = 3) and used for analysis of the contact angle analysis and scanning electron microscope. The Dunnet test showed significant differences between Control group (9.42 ± 2.27 MPa) and Er group (19.25 ± 3.7 MPa) and Sil + Er (14.11 ± 4.11 MPa). ANOVA 2-way (p <5%) for Laser Type (p <0.0001) and Technical of Silanization (p = 0.0002) showed significant differences for both factors, but not for their.. / Doutor
1068

Cinética de degradação de zircônias odontológicas com alta translucidez /

Prado, Pedro Henrique Condé Oliveira. January 2018 (has links)
Orientador: Renata Marques de Melo Marinho / Coorientador: Tiago Moreira Bastos Campos / Banca: Alexandre Luiz Souto Borges / Banca: Eliandra de Sousa Trichês / Resumo: Com o avanço da ciência e processamento de materiais, a zircônia odontológica deixou de ser um material opaco para apresentar certa translucidez, possibilitando a confecção de peças ultrafinas. Sabe-se que a água em contato com a superfície das zircônias convencionais acarreta na transformação de fase T-M e subsequente decréscimo de resistência, mas esses efeitos nas zircônias translúcidas ainda não foram explorados. Para avaliar, mapear e caracterizar os efeitos da cinética de envelhecimento acelerado em zircônias de alta translucidez, foram cortados 39 blocos de Y-TZP (VITA YZ, VITA HT, InCoris TZI) para cada zircônia comercial, onde posteriormente foram sinterizados (1530 ºC, 2h) e atribuídos a 13 grupos com 3 amostras cada: Um controle e 12 envelhecidos hidrotermicamente a 134 ºC com pressão constante de 2 bars por 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 e 140 horas. A análise em DRX foi utilizada para quantificar a transformação de fase da zircônia (tetragonal-monoclínica) em diferentes profundidades do material ao se trocar o ânodo do tubo irradiador (Cr, Co e Cu). Uma curva cinética de envelhecimento foi feita para cada profundidade para as 3 zircônias comerciais. Para avaliar os efeitos do envelhecimento hidrotermal nas propriedades mecânicas, 270 discos de Y-TZP foram cortados, 90 para cada tipo, sinterizados e atribuídos a 3 grupos: C-Controle; E1- envelhecido até 26h e E2- envelhecido até 140 horas. Os discos foram testados em uma máquina de teste universal (EMI... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate, map and characterize the effects of the accelerated aging kinetics of high translucency zirconias, this study was split into 2 parts: One part evaluating the superficial changes after in vitro hydrothermal aging and the second part aiming the effects of this aging on the mechanical properties of those ceramics. 117 Y-TZP (VITA YZ, VITA HT, InCoris TZI) blocks were cut, 39 for each commercial zirconia, sintered (1530 ºC, 2h) and assigned to 13 groups with 3 samples each: One being a control, aging-free group, and 12 groups that were prematurely aged hydrothermally at 134 ºC and constant pressure of 2 bars through 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 and 140 hours. XRD was used to quantify the amount of zirconia phase transformation (tetragonalmonoclinic) on different depths of the material by swapping the anode tube (Cr, Co, and Cu). An aging kinetic curve was made for each depth for the 3 commercial zirconias. To evaluate the effects of the hydrothermal aging on the mechanical properties, Y-TZP blocks were rounded to a cilindrical shape. 270 discs were cut, 90 for each kind, sintered as mentioned above and assigned to 3 groups: C-Control; E1- Aged through 26h and E2- Aged through 140h. Disks were then tested in a universal testing machine (EMIC) under a load of 1000 kg till fracture of the specimen and the surface was evaluated under SEM. The aging kinetics curves work similarly for all the YTZP used in this study, characterized by phase transformation asce... (Complete abstract click electronic access below) / Mestre
1069

Avaliação da distribuição de tensões nas facetas estéticas de porcelana pelo método de elementos finitos

Pereira, João Luiz Neves 08 December 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:12Z (GMT). No. of bitstreams: 1 Joao Luiz Neves.pdf: 1812596 bytes, checksum: a76cbc76ce0b003aad7f933da512d1bd (MD5) Previous issue date: 2005-12-08 / The present work had the objective to evaluate the distribution of tensions in teeth restored with aesthetic porcelain laminates by the finites elements method, in representative models of upper incisors central, where three types of simulation had been used: teeth that did not present dental preparations with and without covering of the incisal edge, and teeth that had preparation in shoulder form and layering of the incisal edge. These models had been submitted to the loads of 100N and 350 N in the incisal edge, under angles of 450 and 900, simulating clinical conditions of carrying patients of class I of the Angle and patients with direct bite of the incisors and/or bruxomanos. We observed that the increase of the load, as well as the reduction of the angulations, had promoted an increase to the tensions in the representative models of porcelain laminate, and that the models represented by the lithium dissilicato porcelain, presented a better behavior in relation to the distribution of the tensions on teeth restored with feldspática porcelain laminate. / O presente trabalho teve por objetivo avaliar a distribuição de tensões nos dentes restaurados com facetas estéticas de porcelana pelo método de elementos finitos, em modelos representativos de incisivos centrais superiores onde foram utilizadas três tipos de simulações: dentes que não apresentavam preparos dentários com e sem recobrimento da borda incisal, e dentes com preparo em forma de ombro e com recobrimento da borda incisal. Estes modelos foram submetidos a cargas de 100N e 350 N na borda incisal, sob angulações de 450 e 900, simulando condições clínicas de pacientes portadores de classe I de Angle e pacientes com mordida de topo e/ou bruxomanos. Foi observado que o aumento de carga, bem como a diminuição da angulação, promoveu um aumento das tensões nos modelos representativos das facetas de porcelana, e que os modelos representados pela porcelana à base de dissilicato de lítio, apresentou um comportamento melhor em relação à distribuição das tensões sobre os dentes restaurados com facetas de porcelana feldspática.
1070

Avaliação da resistência flexural de fibras de vidro e cerâmicas odontológicas utilizadas como subestrutura de próteses parciais fixas

Silva, Adriana de Oliveira 27 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1 Adriana de Oliveira Silva.pdf: 854698 bytes, checksum: 0fe1099b901133907165a1d0a216a8e3 (MD5) Previous issue date: 2004-07-27 / The aim of this study was to evaluate the flexural strength of two fibers glass and two ceramics systems used like substructure of prosthesis fixed partial using a three point bending test. Four groups, with ten specimens and dimensions of 25+ 2mm X 2+ 0,1mm X 2+ 0,1mm (ISO 10477) to fibers glass and 25+ 5 mm X 4+ 0,25 mm X 1,2+ 0,2 mm (ISO 6872) to ceramics were prepared according to the manufacturer’s instructions, where: GI-Vectris Pontic® (Ivoclar/Vivadent), GII-Fibrex Medial® (Angelus Soluções Odontológicas), GIII- IPS Empress ®2(Ivoclar/Vivadent) e GIV- VITA In- Ceram® Zircônia. The specimens were dry stored, in plastic recipient, without light on room temperature and submitted on three point test at universal machine Instron® Corp. 2KN(crosshead speed of 0,75mm/min) and the results of the mean values of flexural strength were 516,04 + 58,44 MPa to GI , 505,23 + 85,57 MPa to GII, 182,73+ 50,33 MPa to the GIII and 442,37 + 99,89 MPa to GIV. The predominance of failure was incomplete fracture to fibers glass and complete fracture to ceramics. The results were submitted on statistical analysis, Anova (p<0,05) and there were observed differences statistically insignificant among the fibers’ group (p=0.7460) and differences statistically significant among the ceramics’ group. Concluded that fibers tested presented similar performance of flexural strength and the result suggested the possibility of fibers glass be used like alternative of alloy in good indication of clinical situation of prosthesis fixed partial. The ceramics presented not similar performance of flexural strength being VITA In-Ceram® Zircônia system able to support more load when compared with IPS Empress® 2 Ivoclar/Vivadent system. / O objetivo deste estudo foi avaliar a resistência flexural de dois sistemas de fibras de vidro unidirecionais e duas cerâmicas utilizadas como subestrutura de próteses parciais fixas, através do teste de três pontos. Quatro grupos, com 10 corpos-deprova cada, e dimensões de 25+2mm X 2+0,1mm X 2+0,1mm (ISO 10477) para as fibras de vidro e 25+ 5 mm X 4+ 0,25 mm X 1,2+ 0,2 mm (ISO 6872) para as cerâmicas, foram obtidos seguindo as orientações dos fabricantes, sendo: GIVectris Pontic® (Ivoclar/Vivadent), GII- Fibrex Medial® (Angelus Soluções Odontológicas), GIII- IPS Empress ®2(Ivoclar/Vivadent) e GIV- VITA In-Ceram® Zircônia. Os corpos-de-prova foram armazenados, secos, à temperatura ambiente, em recipientes plásticos, sem interferência de luz e submetidos ao teste de três pontos em uma máquina de ensaio Instron® Corp. 2KN (velocidade de 0,75mm/min) obtendo-se valores médios de resistência à flexão de 516,04 + 58,44 MPa para GI, 505,23 + 85,57 MPa para GII, 182,73+ 50,33MPa para o GIII e 442,37 + 99,89 MPa para o GIV. O padrão de falha observado foi de fratura incompleta para as fibras de vidro e fratura completa para as cerâmicas. Os valores médios de resistência foram submetidos à análise estatística, teste Anova (p<0,05) e verificou-se a inexistência de diferenças estatísticas significantes entre os grupos de fibras de vidro (p=0.7460) e a existência de diferenças estatísticas significantes entre os grupos de cerâmicas. Concluiu-se que as fibras de vidro utilizadas no experimento apresentaram desempenhos de resistência flexural semelhantes e os resultados sugeriram a possibilidade da utilização das fibras de vidro como alternativa às ligas metálicas em situações clínicas bem indicadas de próteses parciais fixas. As cerâmicas apresentaram diferentes desempenhos de resistência flexural, sendo o sistema VITA In-Ceram® Zircônia capaz de resistir a maior carga aplicada comparada ao sistema IPS Empress® 2 Ivoclar/Vivadent.

Page generated in 0.0493 seconds