• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 902
  • 584
  • 184
  • 96
  • 46
  • 42
  • 21
  • 18
  • 12
  • 11
  • 8
  • 8
  • 7
  • 7
  • 6
  • Tagged with
  • 2332
  • 775
  • 324
  • 323
  • 312
  • 235
  • 177
  • 148
  • 144
  • 141
  • 140
  • 135
  • 133
  • 123
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1011

Efeito da aspersão de água sobre a contaminação microbiológica em esteiras transportadoras de cortes de frango / Effect of woater spray on microbiological contamination in conveyor belts of chicken cuts

Soares, Vanessa Mendonça [UNESP] 28 July 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-28Bitstream added on 2015-05-14T16:59:07Z : No. of bitstreams: 1 000829480.pdf: 377403 bytes, checksum: 7e92763aaee8428dce85038b17519dfb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente estudo teve como objetivo avaliar o efeito do uso de aspersão de água como forma de higiene operacional em esteiras sanitárias condutoras de cortes de frango em quatro linhas de processamento. Em cada linha de processamento, foram coletadas amostras de dois tipos de esteiras (modular e lisa) higienizadas com água e não higienizadas, em quatro tempos distintos (T0, T1, T2 e T3). As amostras foram submetidas à contagem de mesófilos, enterobactérias e pesquisa de L. monocytogenes. Culturas de L. monocytogenes foram submetidas à sorotipagem e a PFGE. Foram realizadas dez repetições do experimento em cada linha de processamento. Com base nos resultados foi possível observar que o efeito da utilização da aspersão com água foi dependente de diversos fatores, tais como a linha de processamento, tipo de corte, design do equipamento e o tipo de esteira. A higienização por aspersão não foi o fator primordial para garantir a eliminação de L. monocytogenes, uma vez que o patógeno foi isolado independente da linha de processamento e tipo de esteira, além disso, os pulsotipos encontrados evidenciaram a disseminação do patógeno nas linhas de processamento avaliadas. Deste modo, a decisão de retirar a água do processo de higienização de esteiras condutoras deve ser precedida de um estudo criterioso para garantir que a sua ausência não venha influenciar na inocuidade dos produtos de origem animal / This study aimed to evaluate the effect of the use of water spray on cleaning of conveyor belts in four broiler lines processing in Brazilian slaughterhouses. Surface samples were collected of two types of conveyor belt (modular and smooth) which passed through two processes (with and without water spray), in four times (T0, T1, T2 and T3). The samples were subjected to mesophilic and enterobacteria count, and research of L. monocytogenes. Cultures of L. monocytogenes were serotyped and submitted to PFGE. Ten replicates of the experiment were performed on each processing line. The results demonstrated that the effect of the use of spraying with water was dependent on several factors, such as the processing line, product type, equipment design and the type of conveyor belt. The cleaning spray is not the primary factor in ensuring the elimination of L. monocytogenes, because the pathogen was isolated independent of the type of conveyor belt and processing line, moreover, PFGE demonstrated the dissemination in the processing lines. Thus, the decision to remove the water from the cleaning of conveyor belts must be preceded by a study to ensure that the absence of this procedure does not influence the safety of products of animal origin
1012

Contaminação microbiológica e avaliação de métodos de higienização de panos de limpeza utilizados em serviços de alimentação / Microbial contamination and evaluation of two disinfection methods of cleaning cloths used in food services

Bartz, Sabrina January 2008 (has links)
Panos de limpeza têm sido considerados importantes fontes de contaminação cruzada, contudo seu uso continua muito freqüente em serviços de alimentação. O objetivo desse trabalho foi avaliar a contaminação e multiplicação microbiana, além de dois procedimentos de higienização de panos de limpeza. Em uma primeira etapa, 35 panos de limpeza foram coletados em serviços de alimentação da grande Porto Alegre, RS/Brasil e foram submetidos à quantificação de bactérias totais, coliformes e Staphylococcus coagulase positiva, aqui chamado de Staphylococcus aureus presuntivos. Os panos foram lavados manualmente e desinfetados por dois métodos, separadamente: a) fervura em água potável por 15 minutos e b) imersão em solução clorada a 200ppm, por 15 minutos, sendo enxaguados logo após. Os resultados demonstraram que a as contagens de bactérias totais variaram de 2,0 x 104 UFC/cm2 até 1,0 x 108 UFC/cm2, com média de 9,1 x 106 UFC/cm2. A contaminação por coliformes foi de 4,4 x 102 a 1,6 x 107 UFC/cm2, sendo que 40% das amostras apresentou contagens de aproximadamente 106 UFC/cm2. Quantidades de S. aureus presuntivos variaram de 1,0 x 104 UFC/cm2 a 2,8 x 106 UFC/cm2, com média de 4,6 x 105 UFC/cm2. De modo geral, panos desinfetados pelos dois métodos demonstraram reduções significativas (p < 0,05) do número de microrganismos, as quais foram de aproximadamente 5 ciclos logarítmicos. Em uma segunda etapa, panos contendo diferentes quantidades de matéria orgânica (0%, 1%, 5% e 10% de albumina bovina) foram contaminados com Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 e Shigella sonnei CC07 e incubados por 1h, 2h, 3h e 4h, a 30 oC. A multiplicação foi avaliada por métodos microbiológicos e por bioluminescência gerada por ATP. Uma bactéria recombinante, ampicilina-resistente (HSα E. coli) foi utilizada para avaliar o potencial de dispersão de panos. Os resultados demonstraram que até duas horas de incubação não houve multiplicação expressiva de todos os microrganismos avaliados, no entanto, em três horas a maioria apresentou leve aumento da população. Uma exceção foi a S. Enteritidis que apresentou multiplicação significativamente maior (p < 0,05). Após quatro horas de incubação, todos os microrganismos apresentaram multiplicação significativa. A bioluminescência confirmou esses resultados e também demonstrou que diferentes quantidades de matéria orgânica não interferiram na multiplicação microbiana nas primeiras 3 a 4 horas. O experimento da dispersão bacteriana demonstrou que um pano contaminado com 104 UFC/cm2 foi capaz de transferir aproximadamente 102 UFC/cm2 de bactérias para uma superfície de aço inoxidável. Baseado nesses resultados, pode-se concluir que panos de limpeza utilizados em serviços de alimentação apresentavam nível elevado de contaminação, porém se adequadamente lavados e desinfetados, suas contagens podem ser significativamente reduzidas. Além disso, sugere-se que panos adequadamente desinfetados sejam utilizados por aproximadamente duas horas, não ultrapassando o período de três horas. / Cleaning cloths have been considered as important cause of cross-contamination, however its use remains frequent in food services. The objective of this study was to evaluate microbial contamination and multiplication, as well as two disinfection methods of cleaning cloths. In a first step of this work, samples (n=35) were collected in food services of Porto Alegre City, RS/Brazil and quantified for microbial contamination. Results indicated total aerobic counts varying from 2.0 x 104 cfu/cm2 up to 1.0 x 108 cfu/cm2, with mean numbers of 9.1 x 106 cfu/cm2. Coliform contamination varied from 4.4 x 102 up to 1.6 x 107 cfu/cm2 per cloth, and 40 % of the samples presented counts around 106 cfu/cm2, while presumptive S. aureus ranged from 1.0 x 104 cfu/cm2 up to 2.8 x 106 cfu/cm2, with mean numbers of 4.6 x 105 cfu/cm2. The cleaning cloths were disinfected in boiling water for 15 minutes and with 200 ppm sodium hypochlorite solution for 15 minutes, separately, demonstrating significant reductions (p < 0.05) of approximately 5 log. In a second step of this study, cloths containing 0 %, 1 %, 5%, and 10% of organic matter (bovine albumin) were contaminated with Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 and Shigella sonnei CC07, and were incubated for 1 h, 2 h, 3 h, and 4 h, at 30 oC. Microbial multiplication was evaluated by bacterial counts and ATP bioluminescence, and an ampicilin-resistant recombinant HSα E. coli was used as a pathogen surrogate to investigate the potential of microbial cloth dispersion. The results demonstrate that until 2 hours of storage all strains did not present expressive growth. In 3 hours of storage the majority of the microorganisms showed slightly development, being that S. Enteritidis grown significantly better than other strains. In 4 hours of incubation all microorganisms demonstrate significant growth (p < 0.05). ATP bioluminescence confirmed the microbial count results and also demonstrates that different amounts of organic matter did not interfere with the bacterial multiplication at the first 3 to 4 hours of incubation. The dispersion experiment indicated that a cleaning cloth contaminated with 104 cfu/cm2 was able to spread approximately 102 cfu/cm2 recombinant E. coli onto a stainless steel surface. Based on these results it was possible to conclude that cleaning cloths used in food services were very contaminated, however adequate sanitation procedures could reduce significantly its microbial contamination. We suggested that an appropriate period of time to use disinfected cleaning cloths is around 2 hours, not exceeding 3 hours of usage.
1013

Presença residual de coliformes totais e salmonella sp., em granjas de terminação de suínos após vazio sanitário.

Sella, Alessandra B. January 2008 (has links)
Os procedimentos de limpeza e desinfecção são pontos chave na prevenção da contaminação por Salmonella sp. No entanto, pouco se conhece a respeito da eficácia de protocolos de limpeza e desinfecção adotados em granjas de terminação de suínos. Desta forma, este estudo teve como objetivo avaliar o nível de contaminação residual de Coliformes Totais e Salmonella sp. em granjas de terminação de suínos, e fazer um levantamento dos protocolos de manejo, instalações e práticas de desinfecção mais utilizados durante o período de vazio dessas granjas. Foram amostradas 71 granjas de terminação integradas a cinco agroindústrias, localizadas no Rio Grande do Sul. Em cada granja, foi aplicado um questionário contendo itens relativos à estrutura e manejo das instalações. Para a análise microbiológica, suabes do piso das baias foram colhidos e submetidos à quantificação de Coliformes Totais e pesquisa de Salmonella. A contagem de Coliformes Totais encontrada nas granjas variou de 6 x102 ufc/cm2 até 4,33 x109 ufc/cm2 Mesmo em granjas integradas a uma mesma empresa houve grande variabilidade na presença de coliformes residuais após a limpeza e desinfecção. Salmonella sp. esteve presente em 26,7% do total de granjas amostradas, com variação de freqüência entre as agoindústrias (0 até 100% das granjas). Observou-se também grande diferença em termos de instalações e práticas de manejo adotadas, o que poderá servir para explicar a contaminação residual numa análise de risco futura. A partir disso, é possível concluir que os protocolos de limpeza e desinfecção adotados nas granjas são pouco eficazes, pois a contagem residual de Coliformes Totais é muito elevada e permitem a presença residual de Salmonella sp. / Cleaning and disinfection practices are the basis of Salmonella control on swine farms. In spite of that, little is known about the effectiveness of the cleaning and disinfection methods used on finishing pig farms. The aim of this study was to evaluate the level of coliform and Salmonella residual contamination on finishing farms, and to assess the practices and disinfection protocols adopted in the all in/all out management. Samplings were conducted in 71 farms associated to five swine companies located in Rio Grande do Sul. On each farm a questionnaire, including issues about building facilities and management, was conducted. Pen floor swabs were taken and submitted to coliform enumeration and Salmonella isolation. Coliform counts ranging from 6 x102 ufc/cm2 to 4.33 x109 ufc/cm2 were found on the sampled farms. Even farms associated to a same company presented a high variation on the coliform counts after cleaning and disinfection. Salmonella sp. was isolated in 26.7% of sampled farms, with a variation on the frequency (0 to 100%) according to the company. A high variability was also detected on the building facilities and management practices adopted. These data can be used in the future to conduct a risk factors analysis. In conclusion, the cleaning and disinfection practices adopted in the sampled farms are little effective, since a high residual coliform counts, and the persistence of Salmonella were detected on the pen floor.
1014

Utilização do método do papel filtro para a determinação das curvas características de um solo coluvionar não saturado contaminado com óleo diesel

Vivian, Juliana Baum January 2008 (has links)
Para a determinação do comportamento de um solo não saturado, é necessária a identificação da sua curva característica, que representa a capacidade de armazenamento de água pelo solo em função do valor de sucção imposto. Quando este solo é submetido a algum processo de contaminação, a sua estrutura interna pode ser alterada por processos físico-químicos, modificando, por conseqüência, o seu comportamento. Esta dissertação propõe uma metodologia de ensaio para a determinação de curvas características de sucção total em um solo artificialmente contaminado com diferentes teores de óleo diesel. O programa experimental proposto consiste basicamente na realização do método do papel filtro, através da técnica sem contato entre a amostra e o papel, com algumas modificações em relação às metodologias anteriormente descritas na literatura geotécnica. Foram também executados ensaios para controle e quantificação da evaporação do contaminante ao longo do tempo, e sua possível absorção pelo papel filtro utilizado. Além disso, foram realizados ensaios para a caracterização física, mineralógica e química do solo, antes e após a adição do óleo, com o intuito de constatar as alterações causadas pela contaminação. O material estudado é constituído por sedimentos coluvionares provenientes de arenito da Formação Botucatu, sendo que sua curva característica, sem contaminação, já foi determinada em um estudo anterior, através do método do papel filtro com contato. Para possibilitar comparações entre estes resultados, foram medidos também alguns pontos em amostras não contaminadas, através da técnica proposta nesta dissertação. Estes apresentaram uma satisfatória concordância em relação à curva anteriormente ajustada. Na análise das curvas características do solo contaminado com 2%, 5%, 10% e 15% de óleo diesel, constatou-se a permanência do formato bimodal, sugerindo que a microestrutura e a macroestrutura continuam influenciando na entrada e saída de água do meio. Entretanto, foram identificadas alterações na forma da curva e na extensão dos patamares resultantes, em relação à curva característica sem contaminação, assim como as diferentes localizações dos valores de entrada de ar. Foi verificado que, conforme o aumento do teor de contaminante, há uma gradual tendência ao formato unimodal da curva característica, induzindo a um comportamento de solo tipicamente granular. Este fato foi comprovado nos resultados de microscopia eletrônica, onde se verifica que, com teores menores de óleo, a estrutura do solo encontra-se mais fechada e, à medida que este teor aumenta, a estrutura torna-se mais porosa. Os tempos de equalização para o método de ensaio proposto variaram entre 7 e 30 dias, conforme o nível de sucção da amostra. A avaliação da histerese revelou que, com o aumento do teor de contaminante, há uma pequena redução deste fenômeno. Além disso, os ensaios complementares comprovaram a existência de uma pequena porcentagem de evaporação do óleo diesel, assim como a absorção do mesmo pelo papel filtro, que se apresentou praticamente nula. / The unsaturated soil behavior can be determined through its soil-water characteristic curve, which represents the capacity of the soil to store water when submitted to different suction levels. When this soil is contaminated, its internal structure can be modified according to physical and chemical processes, thus changing the initial behavior. This dissertation proposes a test methodology to determine the total-suction soil-water characteristic curves of a contaminated soil at different diesel oil contents. The experimental program consisted of using the filter-paper method without contact between the sample and the paper, but with some modifications in relation to previously studied techniques. Some control tests were also carried out to check oil evaporation and its absortion by the filter paper. Besides, the samples were submitted to physical, mineralogical and chemical characterization, before and after contamination, to verify the possible changes. The studied material is a colluvium soil, constituted basically by sandstone, from the Botucatu Formation. This soil was previously studied by the filter-paper method with contact, and its soil water characteristic curve without contamination was already known. To compare the results, the proposed test methodology was also performed with non contaminated samples, showing a satisfactory agreement with the initial curve. The soil-water characteristic curves of this soil with a diesel oil content of 2%, 5%, 10% and 15% showed a "saddle" shape, indicating that both the microstructure and the macrostructure were influenced by the entrance and exit of water through the soil. However, the shape of the curve and the extent of its plateau changed according to the level of contamination. Increasing the oil content, the curve tends to a unimodal shape, with a behavior similar to granular soils. This statement was proved by the microstruture photographs, which showed an increase of sample porosity due to the increase of oil content. The time required to reach suction equilibrium during the tests varied between 7 to 30 days, according to the initial water content of the samples. The observed hysteresis had a small reduction with the increase of oil content. The control tests proved that oil evaporation and its absortion by the filter paper were insignificant in the whole test program.
1015

Fatores de risco para a contaminação bacteriana durante a coleta do ejaculado suíno e suas consequências sobre a qualidade das doses inseminantes / Risk of factors for bacterial contamination during boar semen collection and the consequences on the quality of extended semen doses

Goldberg, Ana Maria Groehs January 2009 (has links)
O objetivo do presente estudo foi verificar a influência de diferentes pontos de risco de contaminação bacteriana durante a coleta do ejaculado suíno e seus efeitos sobre a qualidade da dose inseminante (DI). O experimento foi realizado em quatro centros de difusão genética (CDG), nos quais as coletas dos ejaculados foram observadas buscando possíveis pontos de risco de contaminação. Posteriormente, o sêmen in natura e 2 DIs, provenientes da coleta observada, foram avaliados no que se refere à quantificação bacteriana, morfologia e motilidade espermática e pH. Além do ejaculado, amostras de água e diluente foram avaliadas quanto ao número de unidades formadoras de colônia (UFC). Pêlos prepuciais compridos (>1,0 cm), a higiene da luva de coleta, líquido pingando pela mão do coletador para o interior do recipiente de coleta e a duração da coleta foram os 4, dentre os 12 fatores avaliados, que levaram a um aumento no percentual de ejaculados com valor superior a 220 UFC mL-1 de mesófilos aeróbios (P<0,05). Foi avaliado o efeito isolado ou associado de sete fatores (reprodutor sujo, óstio prepucial sujo, divertículo prepucial grande, pêlos prepuciais compridos, luva de coleta suja, pingos pela mão do coletador para dentro do recipiente de coleta e pênis escapou durante a coleta) que pudessem resultar diretamente na contaminação do ejaculado. Houve aumento significativo do número de ejaculados com contaminação superior a 220 UFC mL-1, a partir da associação de 2 fatores, quando comparados aos ejaculados obtidos em coletas sem nenhum fator predisponente para contaminação. Ao classificar as DIs conforme o grau de contaminação do diluente foram observadas redução na motilidade e no pH e aumento nas alterações de acrossoma das DIs, ao longo das 168 horas de armazenamento, no grupo cujo grau de contaminação do diluente foi superior a 14000 UFC mL-1 versus o grupo com contaminação inferior a 330 UFC mL-1. Doses inseminantes provenientes de ejaculados mais contaminados apresentaram maior grau de contaminação bacteriana. Aparentemente, quando o ejaculado é coletado com um protocolo de contaminação mínima, dificilmente seu grau de contaminação será capaz de produzir efeitos deletérios na qualidade da DI, exceto quando a origem da contaminação for proveniente de falhas higiênicas na linha de processamento das mesmas. A produção de DIs com alta qualidade do ponto de vista bacteriano, somente será possível com um rigoroso controle higiênico na linha de processamento, principalmente no que diz respeito à água e ao diluente, associados a um protocolo de contaminação mínima durante a coleta. / The aim of this study was to check the influence of different risk of factors for bacterial contamination during the collection of ejaculate and the effects in boar extended semen quality. The experiment was conducted in four boar studs, where semen collection was observed, searching for possible risk of factors for bacterial contamination. The ejaculate and two extended semen doses, deriving from the observed collection, were evaluated in regard to numbers of colony-forming units (CFU), sperm morphology and motility, and pH. Water and extender samples were also evaluated for CFU. Long preputial hair (>1 cm), the hygiene of the collection glove, liquid trickling from the hand of the technician into the semen container and the duration of the collection were the four, from twelve factors evaluated, that lead to an increase in the percentage of ejaculates with more than 220 CFU mL-1 of aerobic mesophiles (P<0.05). The isolated or combined effect of seven factors (bad hygiene of boars, dirty preputial ostium, large preputial diverticulum, long preputial hair, dirty collecting glove, liquid trickling from the hand of the technician into the semen container and escape penis during the collection), that could directly result in the contamination of ejaculates was evaluated. There was a significant increase in the number of ejaculates contaminated with more than 220 CFU mL-1 when two or more factors were associated, compared to ejaculates obtained from collections without any predisponent factors. When the extended semen doses were classified according to the degree of contamination of the extender, a decrease in motility and pH and an increase on acrosome alterations in extended semen, during 168 hours of storage, were verified in the group where the degree of contamination was higher than 14,000 CFU mL-1 versus the group with lower than 330 CFU mL-1. Extended semen derived from more contaminated ejaculates showed a higher degree of bacterial contamination. Apparently, when the ejaculate was collected with minimum contamination protocol, its degree of contamination will hardly be able to produce effects in the extended semen quality, unless when the source of contamination was hygienic failure in the processing. The production of semen extended with high quality in the bacterial point of view will only be possible with a strict hygienic control in the processing, mostly in respect to water and extender, associated with minimum contamination protocol during the collection.
1016

Avaliação da contaminação microbiológica e de procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação / Evaluation of microbiological contamination and disinfection procedures of sponges used in food services

Rossi, Eliandra Mirlei January 2010 (has links)
Esponjas de cozinha podem promover contaminação cruzada ao transferirem microrganismos de superfícies variadas para os alimentos. Os objetivos deste estudo foram avaliar a contaminação microbiológica e a eficácia de dois procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação, bem como avaliar a transferência microbiana a partir de esponjas para o aço inoxidável e polietileno. Na primeira parte deste estudo, 80 esponjas naturalmente contaminadas foram coletadas em serviços de alimentação e então transferidas para o laboratório, onde foram divididas em três partes iguais. Uma das partes foi submetida à contagem de microrganismos heterotróficos (MH), coliformes a 45 oC (CF), Staphylococcus coagulase positiva (SA) e à pesquisa de Salmonella sp. (SAM). As outras duas partes foram submetidas, separadamente, à fervura em água durante cinco minutos e à desinfecção por hipoclorito de sódio 200ppm, por 10 minutos, adicionada de enxágue com água potável. Na segunda parte do estudo, 24 esponjas naturalmente contaminadas foram friccionadas sobre superfícies de aço inoxidável AISI 316 e polietileno, separadamente, a fim de investigar o número de microrganismos transferidos e sua sobrevivência. Os resultados demonstraram contaminações médias por MH de aproximadamente 9,1 LogUFC/esponja, e 76,25% delas apresentaram contagens médias de CF de aproximadamente 8,4 Log UFC/esponja. Apenas 2,5% das amostras apresentaram SA e SAM. Ambos os procedimentos de desinfecção foram capazes de reduzir significativamente as contagens bacterianas, porém a fervura demonstrou reduções maiores (6,7 Log UFC/esponja) que a desinfecção por hipoclorito de sódio a 200ppm (2,7 Log UFC/esponja ). A média de transferência de microrganismos variou entre 3,3 e 5,5 LogUFC/cm2, para aço inoxidável, entre 3,5 e 5,6 LogUFC/cm2, para o polietileno, sendo que os microrganismos transferidos foram perdendo sua viabilidade sobre ambos materiais. Nas primeiras quatro horas de exposição em temperatura ambiente a redução do número de microrganismos foi mais acentuada, e em 24 horas restaram cerca de 1 a 2 logUFC/cm2 de microrganismos viáveis. / Kitchen sponges can promote cross-contamination by transferring microorganisms from various surfaces to food. The objectives of this study were to evaluate the microbiological contamination and effectiveness of two procedures for disinfection of sponges used in food services, and to assess the microbial transfer from sponges to stainless steel and polyethylene. In the first part of this study, 80 sponges were collected in food services and then transferred to the laboratory where they were divided into three equal parts. One part was subjected to quantification of heterotrophic microorganisms (HM), fecal coliforms (CF), Staphylococcus coagulase-positive (SA) and Salmonella sp. (SAM). The other two parts were separately subjected to boilling in water for five minutes, and disinfection by sodium hypochlorite 200ppm for 10 minutes, added by rinse with water. In the second part of the study, 24 naturally contaminated sponges were rubbed on surfaces of AISI 316 stainless steel and polyethylene, separately, to investigate the number of transferred microorganisms and their survival. The results showed contamination averages by HM of approximately 9.1 log CFU/sponge, and 76.25% had average scores of CF of about 8.4 log CFU/sponge. Both disinfection procedures were able to significantly reduce bacterial counts, but the boiling showed greater reductions (6.7 log CFU/sponge) than the disinfection by sodium hypochlorite at 200ppm (2.7 log CFU/sponge) The average transfer of microorganisms varied between 3.3 and 5.5 log CFU/cm2 for stainless steel, and 3.5 to 5.6 log CFU/cm2, for polyethylene, and the transferred microorganisms were losing their viability on both materials. In the first four hours of exposure at room temperature the reduction of the number of microorganisms was more pronounced, and in 24 hours there were about 1 to 2 log CFU/cm2 remaining viable microorganisms.
1017

Transferência de elementos maiores, traços e elementos das terras raras no sistema fertilizante - solo - água subterrânea em sedimentos quaternários da Região de Águas Claras, município de Viamão, RS

Vargas, Tiago de January 2010 (has links)
O estudo desenvolveu-se em área de plantação de arroz na região de Águas Claras, Município de Viamão, caracterizada por depósitos arenosos quaternários inconsolidados inseridos no Sistema Laguna-Barreira da Planície Costeira do Rio Grande do Sul. O trabalho teve por objetivo avaliar o impacto do uso intensivo de fertilizantes NPK nos solos e na água do aqüífero livre, verificando a transferência de elementos primários (macro nutrientes), micronutrientes, metais, metalóides e outros elementos-traço (inclusive Elementos Terras Raras) no perfil. Foram coletadas amostras de fertilizante aplicado na área, solos e água em duas áreas fertilizadas e uma não fertilizada (background), realizando-se análises de parâmetros físico-químicos de águas in-loco, análises de difratometria de Raios-X e CTC, e análises multi-elementares com ICP-MS. A coleta de amostras de água foi realizada através de dois poços de monitoramento em três tempos distintos, 6 meses pós-fertilização, duas semanas pré-fertilização e três semanas pós-fertilização. Os solos coletados são classificados como arenosos, contudo, observou-se presença significativa de argila em um perfil. A difração de raios-X identificou presença dos argilominerais ilita e caolinita nas amostras com conteúdo de argila mais elevado. Análises de capacidade de troca de cátions revelaram resultados entre 4,86 e 17,9 cmol/dm3. A condutividade hidráulica do aqüífero freático, registrada através do Teste de Slug resultou em 1,168x10-4 cm/s para o solo do poço com presença maior de argila. No levantamento dos parâmetros de campo observou-se, em quase a totalidade das amostras, as águas possuem pH abaixo de 6 e o conteúdo de sólidos totais dissolvidos situam-se acima do permitido pela Resolução CONAMA 396/08. Os dados químicos de elementos maiores mostram que as águas classificam-se como em praticamente todas as amostras como cloretada-sódico-cálcicas, de acordo com o Diagrama Piper. A análise dos resultados demonstra que o fósforo e magnésio são em sua maior parte adsorvidos no solo, causando efeito cumulativo. Outros elementos químicos que sofreram maior enriquecimento nos solos devido à aplicação de fertilizante foram Al, As, Cd, Cs, Eu, Fe, Li, Mn, Rb, U e V. Nas análises de água detectou-se excesso de manganês, ultrapassando o limite máximo permitido pela Resolução CONAMA 396/08 0,1mg/L, tendo Ce, La e Nd entre os Elementos Terras que tiveram maior enriquecimento. Os resultados demonstram que a aplicação de fertilizantes em aqüíferos com elevada vulnerabilidade pode contaminar as águas subterrâneas, comprometendo sua potabilidade. / This study has been developed in area of rice plantation in the region of Aguas Claras, Municipal District of Viamão, which is comprises quaternary deposits of sandy soils related to the Lagoon-Barrier System of the Rio Grande do Sul Coastal Plain. The main objective was to evaluate the impact of intensive use of fertilizers NPK in the soils and in the free-aquifer, verifying the transfer of primary elements (macronutrients), micronutrients, metals, metalloids and other trace elements (including Elements Rare Earth) in the soil. Samples of fertilizer applied in the plantation, soils, and water in two fertilized areas and in one non-fertilized area (background) were collected. Main physico-chemical parameters of water were measured in the field, while analyses of X-Ray Diffraction, CTC, and multielementary analyses by ICP-MS were processed. The water samples were collected in two monitoring wells in three different periods, 6 months before fertilization, two weeks before fertilization and three weeks after fertilization. The collected soils are classified as sandy, however, significant presence of clay was observed in one profile. The X-Ray Diffraction identified illite and caolinite as the clay minerals phase in samples with higher clay content. Analyses of Cation Exchange Capacity revealed values between 4,86 and 17,9 cmol/dm3. The hydraulic conductivity of the free aquifer through the Slug Test resulted in 1,168x10-4 cm/s for the clayish soil. In the samples majority, the water pH is below 6, and the total dissolved solids is above the limits of the CONAMA Resolution 396/08. The chemical data of major elements show that chlorinated-sodic-calcic water type prevails in the area, according to the Piper Diagram. The chemical results demonstrate that phosphorus and magnesium are mainly adsorved in the soil, causing cumulative effect. Other chemical elements showing higher enrichment in the soil due to fertilizer application were Al, As, Cd, Cs, Eu, Fe, Li, Mn, Rb, U and V. The water analyses detected a manganese excess, according CONAMA Resolution 396/08, while Ce, La and Nd among the REE had larger enrichment. The results clearly demonstrate that intensive fertilizer application in aquifer with high vulnerability can contaminate groundwater.
1018

Estudo do comportamento hidráulico, mecânico e químico de barreiras hidráulicas verticais, compostas por solo residual, bentonita e cimento sob ação de substâncias agressivas / Study of the hydraulic, mechanic and chemical behavior of verticals hydraulic barriers composed by sandy soil, bentonite and cement under aggressive substances’ action

Lemos, Rosemar Gomes January 2006 (has links)
Este estudo tem como objetivo analisar os comportamentos hidráulico, mecânico e microestrutural de misturas compostas, por solo residual arenito Botucatu e bentonita sódica, com e sem adição de cimento, quando permeadas por água (H2O), soda cáustica (NaOH), na concentração de 5% e ácido sulfúrico (H2SO4) na mesma concentração para sua possível utilização em barreiras de contenção de contaminantes do tipo slurry wall. O arenito, solo areno-siltoso característico da região de São Leopoldo/ RS, compõe a matriz das misturas, sendo que a bentonita sódica confere a estas características impermeabilizantes, imprescindíveis às barreiras hidráulicas de contenção. O cimento, além de fazer com que a mistura adquira resistência, interfere na reatividade da barreira, mediante os contaminantes utilizados. A estimativa da eficiência destas misturas baseou-se na comparação entre os valores do coeficiente de condutividade hidráulica, resistência à compressão simples e parâmetros de compressibilidade determinados através dos ensaios de compressão confinada, apresentados nos ensaios com e sem contaminação, conjuntamente com a análise microestrutural das misturas nas mesmas situações. Foram feitas análises químicas por Difração de Raios-x, Microscopia Eletrônica de Varredura (SEM) e Análise Química Elementar (EDS) visando à explicação ordinária das causas microestruturais que levam as misturas a determinado comportamento sob percolação de contaminantes. Na busca do efeito de cada componente sobre o comportamento final de determinada mistura, houve a necessidade de realizar análises químicas e microscópicas individuais, também sob interferência ou não de substâncias agressivas. A partir deste estudo foi possível inferir que a mistura solo-cimentobentonita, é adequada à utilização como barreira vertical quando o contaminante for ácido sulfúrico, por no mínimo 20 semanas, já que a eficiência da mesma foi comprovada pela realização de ensaios no permeâmetro de parede rígida, considerado adequado para este tipo. O uso da mistura solo bentonita para barreiras verticais pode ser emergencial visto que quando o contaminante for soda cáustica a mistura resiste por 4 dias. / The objective of this study is to analyze the hydraulic, mechanical and micro-structural conduct of composite mixtures of Botucatu residual soil and sodic bentonite, with and without cement addition, when permeated by water (H2O), caustic soda (NaOH) in a concentration of 5% and sulfuric acid in the same concentration to their possible utilization in contention of contaminant barriers of the slurry walls type. The sandy soil constitutes part of the matrix of the mixtures. The sodic bentonite confers to these mixture essential waterproof characteristics of hydraulic barriers of containment. The cement interferes on the barrier reactivity moreover add resistance to the mixture by the contaminants that were utilized. The efficiency estimation of these mixtures was established by comparison between hydraulic conductive coefficient, unconfined compression strength and one dimensional compressibility presented on the tests with or without contamination, with the mixture micro-structural and chemical analysis on the same situations: X-ray diffraction, scanning electronic microscopy, Elemental Chemical Analysis (EDS), they want to explain the micro-structural causes that make the mixtures to determinate behavior by percolating of contaminants. Searching the effect of all components about the final behavior of determined mixture there was the necessity to carry out chemical and microscopically individual analysis also by aggressive or non-aggressive substances interference. After completed the study, it is possible to affirm that the soil-cement-bentonite mixture, is good for using as a vertical barrier when the contaminant is sulfuric acid, based on the results of rigid wall permeameter, adequate for this kind of mixture. The use of soilbentonite mixture as vertical barrier for caustic soda could be done just in emergency cases and for a short period of time, once that after some time the barrier reduces drastically its efficiency.
1019

Application of Isoleucine Epimerization to Assess Terrestrial Contamination and Constrain the Duration and Effects of Aqueous Alteration of Carbonaceous Chondrite Meteorites

January 2014 (has links)
abstract: Carbonaceous chondrites (CCs) present a unique opportunity for learning about the earliest organic chemistry that took place in our Solar System. The complex and diverse suite of meteoritic organic material is the result of multiple settings and physicochemical processes, including aqueous and thermal alteration. Though meteorites often inform origin-of-life discussions because they could have seeded early Earth with significant amounts of water and pre-biotic, organic material, their record of abiotic, aqueous, and organic geochemistry is of interest as well. CC materials previously resided on asteroidal parent bodies, relic planetesimals of Solar System formation which never accreted enough material to develop long-lived, large-scale geological processes. These bodies were large enough, however, to experience some degree of heating due to the decay of radiogenic isotopes, and the meteorite record suggests the existence of 100-150 parent bodies which experienced varying degrees of thermal and aqueous alteration for the first several 10 Myr of Solar System history. The first chapter of this dissertation reviews literature addressing aqueous alteration as an essential participant in parent body geochemistry, organic synthesis, or both (though papers which address both are rare). The second chapter is a published organic analysis of the soluble organic material of Bells, an unclassified type 2 chondrite. Analytical approaches to assess terrestrial contamination of meteorite samples are also reviewed in the first chapter to allow introduction in chapter 3 of kinetic modeling which rules out certain cases of contamination and constrains the timing of thermal and aqueous alteration. This is the first known application of isoleucine epimerization for either of these purposes. Chapter 4 is a kinetic study of D-allo-isoleucine epimerization to establish its behavior in systems with large, relative abundances of alloisoleucine to isoleucine. Previous epimerization studies for paleontological or geological purposes began with L-isoleucine, the only protein amino acid of the four isoleucine stereoisomers. Kinetic model calculations using isoleucine stereoisomer abundances from 7 CR chondrites constrain the total duration of the amino acids' residence in the aqueous phase. The comparatively short timescales produced by the presented modeling elicit hypotheses for protection or transport of the amino acids within the CR parent body. / Dissertation/Thesis / Doctoral Dissertation Chemistry 2014
1020

Source Strength Impact Analysis on Insulator Flashover under Contaminated Conditions

January 2016 (has links)
abstract: Transmission voltages worldwide are increasing to accommodate higher power transfer from power generators to load centers. Insulator dimensions cannot increase linearly with the voltage, as supporting structures become too tall and heavy. Therefore, it is necessary to optimize the insulator design considering all operating conditions including dry, wet and contaminated. In order to design insulators suitably, a better understanding of the insulator flashover is required, as it is a serious issue regarding the safe operation of power systems. However, it is not always feasible to conduct field and laboratory studies due to limited time and money. The desire to accurately predict the performance of insulator flashovers requires mathematical models. Dynamic models are more appropriate than static models in terms of the instantaneous variation of arc parameters. In this dissertation, a dynamic model including conditions for arc dynamics, arc re-ignition and arc motion with AC supply is first developed. For an AC power source, it is important to consider the equivalent shunt capacitance in addition to the short circuit current when evaluating pollution test results. By including the power source in dynamic models, the effects of source parameters on the leakage current waveform, the voltage drop and the flashover voltage were systematically investigated. It has been observed that for the same insulator under the same pollution level, there is a large difference among these flashover performances in high voltage laboratories and real power systems. Source strength is believed to be responsible for this discrepancy. Investigations of test source strength were conducted in this work in order to study its impact on different types of insulators with a variety of geometries. Traditional deterministic models which have been developed so far can only predict whether an insulator would flashover or withstand. In practice, insulator flashover is a statistical process, given that both pollution severity and flashover voltage are probabilistic variables. A probability approach to predict the insulator flashover likelihood is presented based on the newly developed dynamic model. / Dissertation/Thesis / Doctoral Dissertation Electrical Engineering 2016

Page generated in 0.076 seconds