High frequency near-threshhold corrosion fatigue of AISI 316L stainless steelFong, Clinton January 1985 (has links)
High frequency corrosion fatigue crack propagation behavior of AISI 316L stainless steel was studied in 1M NaCl and 1M NaCl + 0.01M Na₂S₂O₃, under various anodically and cathodically polarized potentials, and dessicated air at 22°C and 1 atmosphere pressure. Constant load amplitude fracture mechanics techniques employing single edge notch specimens were used to assess the fatigue crack growth rate in the various environments. Unique specimen preparation procedures were developed which allowed near-threshold behaviors to be studied under gradually rising crack tip stress intensity conditions.
Polarization studies showed that the presence of thiosulphate catalyzed the dissolution of stainless steel in low pH solutions(pH~1), due to reduction of thiosulphate species to H₂S, but had no effect in the near neutral solutions. Fatigue
tests conducted in the neutral NaCl + Na₂S₂O₃ solution at cathodic potentials showed that the presence of thiosulphate had an insignificant effect. This indicated that high frequency fatigue produces efficient exchange of bulk solution with the crack tip environment, which prevented the lowering of pH in the crack by hydrolysis effects and prevented reduction of thiosulphate to H₂S.
Fatigue crack retardation phenomena were very pronounced in the near-threshold regions in most of the fatigue tests. The cause of this retardation was attributed mainly to the surface-roughness- induced crack closure effect, which reduced the effective crack tip cyclic stress intensity ΔKth to a lower
level. This closure effect only predominated in the near-threshold region where significant Mode II loading was present.
The influence of various imposed anodic and cathodic potentials was found to be consistent with the surface-roughness-induced crack closure effects. The observed crack growth accelerating effect of high anodic potentials was attributed to the corresponding high removal rate of surface roughness in the wake of the crack, which kept the effective cyclic stress intensity level near the applied values.
Crack fractography was studied by scanning electron microscopy. It showed that the fractography generally consisted of three regions; a crystallographic cleavage-like near-threshold region, a feathery and fibrous transition region, and a striated region.
Using an etch pitting technique, it was determined that the crack plane and crack propagation directions in the near-threshold region were mainly those of {111} <110>, {110} <112>, {110} <001>, and other higher indexed planes. These crack orientations were effected by the activation of a single slip system or the alternate activation of two intersecting slip systems. / Applied Science, Faculty of / Mechanical Engineering, Department of / Graduate
|
2 |
Acoustic emissions from fatigue cracks in steelsMathieson, P. A. R. January 1987 (has links)
No description available.
|
3 |
Environment-sensitive cracking of 7000 series aluminium alloysHepples, W. January 1987 (has links)
No description available.
|
4 |
A study of fatigue crack propagation in quenched and tempered and controlled rolled HSLA steelsCallister, D. R. January 1987 (has links)
A range of HSLA steels reflecting the two major processing routes, quench and tempering and controlled rolling, have been tested in fatigue to assess their potential wider application in the offshore Industry. The six steels chosen have a wide range of yield strenghts (470 to 690Nmm-2), fracture toughness (31 to 260J at -40°C) and carbon equivalent values (0.19 to 0.33). Fatigue testing has in general been carried out at low frequency (0.5Hz) and high load ratio (0.6) however some tests have been conducted at very low frequency (0.1Hz) and low load ratio (0.1). An in-air study was first used to assess the fatigue performance of all six parent plates. Five steels were welded by the Submerged Arc Welding process at high heat input (1.5kJmm -1) to evaluate the Heat Affected Zone (HAZ) fatigue performance. A new test was devised to grow a fatigue crack through a single pass, bead on plate-, HAZ whilst maintaining a constant stress intensity range. The surface crack length was continuously monitored and recorded to an accuracy of 0.01mm. A corrosion fatigue study evaluated the performance of one controlled rolled and one quenched and tempered steel at three levels of impressed current cathodic protection. Extensive metallographic examination was made to study the influence of microstructural features and types on fatigue crack propagation. Techniques used include optical microscopy, scanning electron microscopy, fatigue crack and surface replication and crack profile digitising. These techniques give an assessment of crack path deviation and branching, the influence of precipitates and inclusions, and an indication of the mode of fatigue crack propagation. The wide range of microalloyed HSLA steels tested have shown a significant improvement in fatigue crack propagation resistance over structural steels conforming to BS 4360 grade 50D. Typically an improvement by a factor of two has been observed. Whilst the observed increase in fatigue life was slightly reduced by high heat input welding the slope of the Paris curves remained unaffected thus indicating a similar stress intensity range sensitivity in the HAZ to that shown by the parent plate. The newly developed crack monitoring system coupled to a computer controlled fatigue testing machine has shown a wide variation in fatigue crack propagation rates through a heat affected zone microstructural gradient. Growth rates have increased by a factor of ten in localised coarse grained microstructural regions compared to the adjacent weld metal and outer heat affected zone. The corrosion fatigue study has also indicated that in general HSLA steels retain their superiour fatigue resistance compared to structural steels and in particular respond more favourably to cathodic protection. Both in-air and corrosion fatigue studies have indicated that the controlled rolled steel microstructures developed mainly for line pipe application has the greatest potential for increased use offshore.
|
5 |
Corrosion of composite tube air-ports in kraft recovery boiler: Cr₂O₃, Fe₂O₃, NiO solubility in molten hydroxideEstes, Matthew J. 07 1900 (has links)
No description available.
|
6 |
Integrity of offshore structuresAdedipe, Oyewole January 2015 (has links)
Corrosion and fatigue have been dominant degradation mechanisms in offshore structures, with the combination of the two, known as corrosion fatigue, having amplified effects in structures in the harsh marine environments. Newer types of structure are now being developed for use in highly dynamic, harsh marine environments, particularly for renewable energy applications. However, they have significantly different structural details and design requirements compared to oil and gas structures, due to the magnitude and frequency of operational and environmental loadings acting on the support structures. Therefore, the extent of corrosion assisted fatigue crack growth in these structures needs to be better understood. In this research, fatigue crack growth in S355J2+N steel used for offshore wind monopile fabrications was investigated in air and free corrosion conditions. Tests were conducted on parent, HAZ and weld materials at cyclic load frequencies similar to what is experienced by offshore wind monopile support structures. The seawater used for testing was prepared according to ASTM D1141 specifications and was circulated past the specimens through a purpose designed and built corrosion rig at a rate of 3 l/min, at a temperature of 8-100C and at a pH of 7.78-8.1. A new crack propagation method accompanied by constant amplitude loading was used. Crack growth rates in parent, HAZ and weld materials were significantly accelerated under free corrosion conditions, at all the stress ratios used compared to in air environment. However, in free corrosion conditions, crack growth rates in the parent, HAZ and weld materials were similar, particularly at a lower stress ratio. The results are explained with respect to the interaction of the loading condition, environment and the rate of material removal by corrosion in the weldments. A new model was developed to account for mean stress effects on crack growth rates in air and in seawater, and was found to correlate well with experimental data as well as with the other mean stress models tested.
|
7 |
An investigation into the corrosion fatigue behaviour of high strength carbon steel tensile armour wiresBarnes, Peter Edward January 2015 (has links)
The corrosion fatigue behaviour of high strength carbon steel tensile armour wires that are used in flexible risers has been explored. An investigation of the corrosion fatigue failure mechanisms for two different sets of corrosion fatigue tested high strength steel wires has been carried out. The two different tensile armour wires were 12 mm x 4 mm and 12 mm x 7 mm. The wires had been corrosion fatigue tested in up to three different seawater environments, namely aerated, CO2 saturated to 1 bar absolute and 100 mbar absolute H2S-CO2 balance to 1 bar absolute. The corrosion fatigue failure investigation included undertaking statistical analysis of fatigue crack and corrosion pit data to establish the effects of environment, applied stress, R-ratio and microstructure due to degree of cold drawing on the corrosion fatigue behaviour. The 12 mm x 4 mm has fine grain martensite-pearlite structure with anisotropic microstructure in the transverse plane. The 12 mm x 7 mm has larger grain martensite-pearlite structure with equiaxed microstructure in the transverse plane. The corrosion fatigue crack path for the two tensile armour wires exhibits transgranular and intergranular cracking due to variations in R-ratio and microstructure. The analysis identified that a significant amount of localised corrosion pitting was present on the surface of both the 12 mm x 4 mm and 12 mm x 7 mm high strength carbon steel tensile armour wires and that many corrosion fatigue cracks had initiated from these geometric discontinuities. A method was developed in order to apply an optical image correlation technique to a sample immersed in seawater. The research has shown that digital image correlation may be applied for in-situ imaging of a corroding and dynamically deforming surface within a seawater environment. The technique demonstrated the establishment of localised surface strain around the corrosion pits during mechanical loading. The results of the surface strain mapping show that the interaction between multiple corrosion pits is consistent with a significant increase in surface strain when compared to a single surface pit acting alone. The results also show that a small single stress raiser can exhibit a high surface stress concentration when compared to a larger one as the strain is dependent upon the geometry of the pit. The highest strain concentration is at the edge of the pit, parallel to the loading direction. The results show the interaction that multiple pits have with each other, the effect they have on surface strains and how they and other types of stress raiser lead to premature failure of components. Further to this the effects of residual stress on crack nucleation were considered. Fatigue cracks initiate at the surface of the high strength carbon steel tensile armour wire therefore surface measurements were carried out to establish the effects of environment and applied load on the development of residual stress fields. The 12 mm x 4 mm wire shows some correlation between applied stress range and surface residual stress measurements with. For the 12 mm x 4 mm wire corrosion fatigue tested in aerated seawater the surface residual stress becomes increasing compressive with an increase in applied stress. For the 12 mm x 4 mm wire corrosion fatigue tested in CO2 saturated seawater the surface residual stress appears to be independent of applied stress. However for the 12 mm x 7 mm carbon steel tensile armour wire there is no correlation between the applied stress range and the surface residual stress. The differences in surface residual stress may be due to the differences in R-ratio, microstructure and level of cold drawing due to the Bauschinger effect. Surface residual stress measurements have been used to explore the effects of the shakedown process on the high strength carbon steel tensile armour wires prior to corrosion fatigue testing. They show that at a high applied stress range the shakedown process readily develops a compressive residual stress on the surface of the carbon steel wire. This is mostly the case for the low applied stress range; however care should be taken when considering the effects of shakedown on a lower stress range in so far as it may not completely remove the tensile residual stress. Through thickness residual stress measurements show a similar distribution of residual stress fields throughout the high strength carbon steel tensile armour wires independent of the applied stress range and environment.
|
8 |
Corrosion fatigue of engineering alloys in aqueous environmentsHarty, Brian Dudley January 1990 (has links)
A comparative study of the fatigue crack growth rate (FCGR) behaviour of five alloys in air and in aqueous environments has been performed. The alloys tested include: mild steel as a reference material, a corrosion resistant dual phase steel, 3CR12, a proprietary martensitic stainless steel, AISI 431, a newly developed 8% Cr martensitic steel, Alloy 825, and a newly developed corrosion-abrasion resistant metastable austenitic alloy, 1210. Tests were conducted in laboratory air, distilled water at rest potential, 500 ppm chloride solution at rest potential, 1000 ppm chloride solution at rest potential, and 1000 ppm chloride solution at -1200 m V see; solution temperatures were maintained at 25⁰ C. Crack growth rate tests were performed using sinusoidal loading at a load ratio R = 0.1, a frequency of 3Hz in the laboratory air, and a frequency of 1 Hz in the aqueous environments. At the completion of testing, fracture surfaces were studied using a scanning electron microscope. In air, the mild steel and 3CR12 display comparable rates of cracking and exhibit a greater resistance to fatigue crack propagation than the martensitic AISI 431 and Alloy 825; Alloy 825 shows the least resistance to fatigue crack propagation. The deformation induced transformation in 1210 gives this alloy the greatest resistance to fatigue crack propagation in air. Fatigue crack growth rates were all enhanced in the aqueous environments. The greatest overall rate of environmentally assisted cracking was shown by alloy 825 while the lowest was shown by the mild steel. Although the rate of cracking of 1210 in the aqueous environments was less than that of Alloy 825, 1210 was influenced the most by the aqueous environments. An environmentally assisted cracking index shows that the rate of fatigue crack propagation in 1210 is increased by 32 times in the 500 ppm chloride solution at low stress intensities. The fatigue crack growth rates of mild steel and AISI 431 were significantly influenced by the cathodically polarised conditions in the 1000 ppm chloride solution, compared to the rest potential conditions. In these cases hydrogen was seen to be evolved from the specimen surfaces. Changes in the fatigue crack growth rate behaviour were accompanied by changes in the fracture surface morphologies. The observed changes varied for each alloy and for each environment, and were manifest by the degree of intergranular cracking, cleavage, quasi cleavage, and increased coarseness of the transgranular cracking. The fracture surface morphologies are reported and discussed in detail. In general, the fracture surface morphologies could be directly related to the relative degrees of environmental influence on the rate of cracking; results are explained in terms of existing hypotheses. It is suggested that the environmentally assisted cracking of mild steel and AISI 431 at cathodic potentials in the 1000 ppm chloride solution could only be attributed to hydrogen assisted cracking. Similarly, it is suggested that the large crack growth rate acceleration of 1210 in the aqueous environments could also be attributed to hydrogen. The similar fracture surface morphologies observed on the other specimens after tests in the aqueous environments suggests-that hydrogen could be responsible for the environmentally assisted cracking of all the steels in aqueous environments.
|
9 |
Corrosion Fatigue Performance of In-service and Laboratory Accelerated Sensitized AA5456-H116 for Marine ApplicationsAkman, Allison Michelle 05 October 2021 (has links)
No description available.
|
10 |
Development of a Multiscale Internal State Variable Inelasticity-Corrosion Damage Model for Magnesium AlloysSong, Weiwei 14 August 2015 (has links)
This dissertation proposes a multiscale Internal State Variable (ISV) inelasticity-corrosion damage model that is motivated by experimental microstructure-property relations of magnesium alloys. The corrosion damage framework was laid out based on observation of different corrosion mechanisms occurred on an extruded AM30 magnesium alloys. The extruded AM30 magnesium alloy was studied under two corrosion environments (cyclical salt spray and immersion) in order to observe the corrosion rates under different exposure environments. The coupons were examined at various times to determine the history effects of three corrosion mechanisms: (1) general corrosion; (2) pitting corrosion in terms of the nucleation rate, growth rate, and coalescence rate; and (3) intergranular corrosion. The multiscale ISV corrosion model was developed by bridging the macroscale corrosion damage to the mesoscale electrochemical kinetics, microscale material features, and nanoscale material activation energies. The corrosion testing results of Mg alloys (pure Mg, Mg-2% Al, and Mg-6% Al) were used to develop, calibrate, and validate the model, and good agreement was found between the model results and the corrosion testing data. Finally, the simultaneous effects of corrosion and cyclic loading were tested but not modelled for the extruded AM30 magnesium alloy by conducting fatigue experiments in a 3.5 wt.% NaCl solution environment. The corrosion fatigue life of the AM30 alloy was significantly reduced due to corrosion pit formation on specimen surface, hydrogen diffused into the material , and the fracture surface dissolved into the solution. The corrosion damage that arose on the fatigue specimens reduced the crack nucleation process and enhanced the crack propagation rate.
|