• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 757
  • 687
  • 90
  • 62
  • 39
  • 39
  • 32
  • 26
  • 11
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 2123
  • 2123
  • 661
  • 659
  • 357
  • 184
  • 183
  • 180
  • 172
  • 159
  • 144
  • 142
  • 117
  • 116
  • 116
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
621

Aplicações do approximate Bayesian computation a controle de qualidade / Applications of approximate Bayesian computation in quality control

Campos, Thiago Feitosa 11 June 2015 (has links)
Neste trabalho apresentaremos dois problemas do contexto de controle estatístico da qualidade: monitoramento \"on-line\'\' de qualidade e environmental stress screening, analisados pela óptica bayesiana. Apresentaremos os problemas dos modelos bayesianos relativos a sua aplicação e, os reanalisamos com o auxílio do ABC o que nos fornece resultados de uma maneira mais rápida, e assim possibilita análises diferenciadas e a previsão novas observações. / In this work we will present two problems in the context of statistical quality control: on line quality monitoring and environmental stress screening, analyzed from the Bayesian perspective. We will present problems of the Bayesian models related to their application, and also we reanalyze the problems with the assistance of ABC methods which provides results in a faster way, and so enabling differentiated analyzes and new observations forecast.
622

Desenvolvimento e validação de metodologia analítica em cromatografia gasosa para o controle de qualidade de \'Eucalyptus globulus\' e seus produtos: planta desidratada, extratos, óleo essencial e xarope de eucalipto / Development and validation of analytical methodology by gas chromatography for the quality control of Eucalyptus globulus and products: raw material, extracts, essential oil and eucalyptus syrup

Bueno, Paula Carolina Pires 24 September 2007 (has links)
O gênero Eucalyptus, família Myrtaceae, é composto por mais de 400 espécies, das quais a maioria é nativa do continente australiano. Dentre as espécies mais conhecidas, o Eucalyptus globulus tem sido tradicionalmente utilizado pela população no tratamento de doenças respiratórias devido a seus efeitos expectorante, fluidificante e antisséptico. Assim, como para todos fitoterápicos, durante o desenvolvimento de um novo produto é imprescindível que os parâmetros de segurança, eficácia e qualidade sejam devidamente certificados e assegurados. Para tanto, é necessário desenvolver e validar metodologias analíticas para o controle de qualidade e, desta forma, assegurar o efeito terapêutico desejado. Sendo assim, o objetivo deste trabalho foi desenvolver e validar uma metodologia analítica capaz de quantificar com exatidão o teor de 1,8-cineol em óleo essencial, planta desidratada e extratos de E. globulus, bem como em xarope à base de extrato fluido desta espécie. O método analítico foi desenvolvido e validado em cromatógrafo de fase gasosa da marca Hewelett Packard Agilent Tecnologies, Inc, modelo 6890N, equipado com injetor split/splitless e detector de ionização em chama. O injetor operou no modo split (razão 20:1), à temperatura de 250 °C, enquanto o detector operou à temperatura de 270 °C. Como gás de arraste utilizou-se hidrogênio, com fluxo de 2,2 mL/min. Para as análises utilizou-se coluna capilar de sílica fundida HP-5 (5% fenil-metil-siloxano) de dimensões: 30,0 m x 320,0 µm x 0,25 µm. O programa de temperatura do forno iniciou-se em 75 °C e foi concluído a 200 °C, no período de 20 minutos. A identificação dos principais componentes presentes na espécie foi realizada utilizando-se cromatografia gasosa com detecção de massas (CG-EM). Para a análise qualitativa foram obtidos fingerprints de 12 espécies de Eucalyptus, a citar: E. botryoides, E. citriodora, E. elba, E. globulus, E. grandis, E. microcorys, E. paniculata, E. resinifera, E. robusta, E. saligna, E. tereticornis e E. urophylla. O cromatograma do óleo de E. globlulus apresenta um pico majoritário em 5,23 minutos, correspondente ao 1,8-cineol. Já os cromatogramas das outras espécies, possuem diferenças e semelhanças significativas, tanto na presença de metabólitos quanto na quantidade de cada um, o que permite a identificação preliminar de cada espécie por este método. Além da seletividade e linearidade alcançadas, a porcentagem de recuperação ficou situada em 99,8% para as folhas de eucalipto e 100,5% para o xarope. A precisão, determinada pelo desvio padrão relativo de sextuplicatas à concentração do teste para as folhas e xarope foi de 1,86% e 0,92% respectivamente, ou seja, dentro do limite estabelecido ela ANVISA que é de, no máximo 5%. Finalmente, foram determinados os limites de detecção (4,79 g/mL) e quantificação (14,51g/mL) e avaliada a influência dos principais parâmetros modificados deliberadamente na determinação da robustez, através do teste de Yuden. Sendo assim, o método desenvolvido, utilizando padronização interna, se mostrou adequado para a quantificação do marcador 1,8-cineol não só nas folhas, extratos e óleo essencial de E. globulus, mas também em xarope contendo o extrato desta espécie, garantindo a rastreabilidade de todo o processo produtivo. / The genus Eucalyptus, family Myrtaceae, is composed of more than 400 species, most of them native to Australia. From the most known species, Eucalyptus globulus has been traditionally used for the treatment of respiratory diseases because of its expectorant, mucolytic and antiseptic effects. As occurs for all phytomedicines, during the development of a new product, it is indispensable to guarantee and to certify the security, efficacy and quality parameters. For this reason, it is necessary to develop and validate analytical methodologies for the quality control system and to assure the desired therapeutic effect. Therefore, the aim of this work was to develop and validate an analytical methodology capable to quantify, with accuracy, the 1.8-cineol content in E. globulus essential oil, dried leaves, extracts and syrup. The analytical procedure was developed and validated using a Hewlett-Packard 6890N gas chromatograph (Agilent Technologies, Inc.) equipped with a split/splitless injector inlet and a flame ionization detector. The injector operated in the split mode (20:1), at 250 °C, while the detector operated at 270 °C. Hydrogen at a flow rate of 2.2 mL/min was employed as carrier gas. An HP-5 capillary column (30 m of length x 0.32 mm of internal diameter x 0.25 µm of film thickness) was used for the analysis and the non linear increasing temperature gradient was: 75 °C to 200 °C, in 20 min. The identification of the main compounds of E. globulus was made using GC-MS. For the qualitative analysis the fingerprints of 12 Eucalyptus species were obtained: E. botryoides, E. citriodora, E. elba, E. globulus, E. grandis, E. microcorys, E. paniculata, E. resinifera, E. robusta, E. saligna, E. tereticornis and E. urophylla. The chromatogram of E. globulus shows the main peak (1.8-cineol) at 5.23 minutes. The chromatograms of the other species have some significant differences and similarities in the presence and quantity of metabolites, a fact that allows a preliminary identification of each specie by this method. Besides the selectivity and linearity achieved, the recovery was at 99.8% for the leaves and 100.5% for the syrup. The repeatability, determined by the relative standard deviation in six replicates at test concentration, was 1.86% and 0.92%, respectively. This result is in agreement with the Brazilian regulamentation (the maximum value established for ANVISA is 5%). The detection limit was 4.79 g/mL while the quantification limit was 14.51g/mL. Finally, the influence of the main modified parameters for the robustness was determined using the Yuden test. The developed method, with internal standardization, proved to be reliable for the quantification of 1.8-cineol, not only in eucalyptus leaves, extracts and essential oils, but also in syrup formulations containing this plant extract, avowing the rastreability of the entire manufacturing process.
623

Optimisation automatique des incidences des faisceaux par l'algorithme du simplexe et optimisation des contrôles qualité par la Maîtrise Statistique des Processus (MSP) en Radiothérapie Conformationnelle par Modulation d'Intensité (RCMI) / Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (SPC) for intensity modulated radiation therapy (IMRT)

Gérard, Karine 07 November 2008 (has links)
La Radiothérapie Conformationnelle par Modulation d’Intensité (RCMI) est aujourd’hui reconnue comme une technique de référence permettant d’augmenter le contrôle local de la tumeur tout en réduisant la dose reçue par les organes à risques avoisinants. Cependant, son développement est freiné par l’étape de préparation du traitement du patient qui nécessite une charge de travail considérable. Dans le but d’augmenter l’efficience de la mise en œuvre d’un traitement, deux axes de travail ont été déterminés. Le premier axe concernait l’optimisation automatique des incidences des faisceaux. Nous avons pour cela mis en œuvre un algorithme (le simplexe) qui a été intégré dans le système de planification de traitement. Il permet, à partir des objectifs dosimétriques fixés par l’utilisateur, de déterminer automatiquement les incidences de faisceaux optimales : irradiant suffisamment le volume cible tout en épargnant les organes à risques avoisinants. En plus d’un gain en temps, les résultats du simplexe ont montré – sur trois patients atteints d’un cancer de l’oropharynx – un gain en qualité par rapport à une sélection manuelle des faisceaux. En effet, pour une couverture du volume cible équivalente voire meilleure, il permet de réduire la dose reçue par les organes à risques. Le second axe concernait l’optimisation des contrôles pré-traitement. Nous avons pour cela utilisé une méthode industrielle : la Maîtrise Statistique des Processus (MSP) afin d’analyser rétrospectivement les résultats des contrôles de la dose absolue effectués avec la chambre d’ionisation au Centre Alexis Vautrin (CAV). Cette étude a montré l’intérêt de la MSP pour renforcer la sécurité des traitements grâce à la mise en place de cartes de contrôle. Elle a également montré que notre processus de délivrance de la dose était stable et statistiquement capable pour les traitements de la prostate, ce qui implique qu’une réduction du nombre de contrôles peut être envisagée pour ce type de traitement au CAV / Intensity Modulated Radiation Therapy (IMRT) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (SPC) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (CAV). This study showed that SPC is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the CAV
624

Gel Turnbull Blue aplicado à dosimetria de radiação ultravioleta e visível / Turnbull Blue Gel applied to ultraviolet and visible radiation dosimetry

Borguezan Neto, Euclydes 21 October 2016 (has links)
O gel radiocrômico Turnbull Blue (TBG) é sensível a raios gamma e x. Este composto tem sido utilizado em dosimetria de radiações ionizantes devido à sua capacidade de simular tecido biológico quando exposto à radiação de alta energia. Após sua irradiação, o TBG sofre uma mudança de cor: o aspecto amarelo torna-se azul devido à formação do corante Turnbull Blue. Essa alteração de cor produz uma larga banda de absorção na faixa espectral do visível, com pico localizado em 690 nm. A intensidade desta banda é proporcional à dose de radiação absorvida. Entretanto, o comportamento do TBG, quando exposto a radiações menos energéticas, como luz visível e ultravioleta, ainda não é conhecido. Considerando as recomendações de organizações internacionais sobre os riscos do uso de tais radiações, esta pesquisa teve como objetivo caracterizar a resposta do TBG, quando irradiado por diferentes fontes ultravioletas e visíveis, tais como lâmpadas fluorescentes, LEDs e um simulador solar. O tempo entre a exposição do gel e a leitura de sua resposta foi estudado, assim como a influência da utilização de fontes com diferentes irradiâncias e diferentes temperaturas de irradiação. Um espectrômetro, operando na faixa espectral de 350 nm a 900 nm, foi utilizado para mensurar a mudança de cor no gel. Os resultados mostraram que o gel possui diferentes sensibilidades de acordo com a faixa espectral entregue pela fonte: a radiação UVC produziu a alteração de cor mais intensa, seguida pela UVB, UVA e visível, respectivamente. A temperatura de irradiação e a irradiância da fonte tiveram influência considerável na mudança de cor do TBG. Os resultados mostraram que é possível usar o gel TBG como um dosímetro de radiação óptica, desde que fatores de correção relacionados à irradiância da fonte e temperatura de irradiação sejam levados em consideração. / The radiochromic gel Turnbull Blue (TBG) is sensitive to gamma and x-rays. This compound has been utilized in ionizing radiation dosimetry, since it acts as biological tissue simulator when exposed to high-energy radiation. Subsequently to its radiation, TBG shows a color shift: the original yellow aspect becomes blue due to the production of the colorant Turnbull Blue. Such chromic shift yields a broad absorption band in the visible spectral range, with a peak located at 690 nm. The intensity of this band is proportional to the absorbed radiation dose. However, the behavior of TBG when exposed to less energetic radiation, e.g. ultraviolet and visible light, remains unclear. Considering the recommendations of international organizations regarding the risks of using such type of radiation, this research aimed to characterize the TBG response when irradiated by different ultraviolet and visible sources as well as to determine its sensitivity to the radiation in the UV-Visible spectral range. Furthermore, this investigation evaluated the viability of TBG as an optical dosimeter. During this study, the gel was exposed to different non-ionizing radiation sources, such as fluorescent lamps, LEDs and a sun simulator. The time between the gel exposition and the measurement of its response was studied, as well as the influence of different source irradiances and temperatures of irradiation. A spectrometer operating on the 350-900 nm spectral range has measured the gel color shift. The results showed different sensitivities according to the spectral range delivered by the source: UVC has produced the most intense change in color, followed by UVB, UVA and visible, respectively. The temperature of irradiation and the irradiance provided by the sources have shown considerable influence on the color shift. The results showed that it is possible to use the TBG gel as optical radiation dosimeter. The use of correction factors for temperature of irradiation and irradiance of the source are mandatory.
625

Prognostic COPD healthcare management system

Unknown Date (has links)
Hospital readmission rates are considered to be an important indicator of quality of care because they may be a consequence of actions of commission or omission made during the initial hospitalization of the patient, or as a consequence of poorly managed transition of the patient back into the community. The negative impact on patient quality of life and huge burden on healthcare system have made reducing hospital readmissions a central goal of healthcare delivery and payment reform efforts. In this project, we will focus on COPD (Chronic Obstructive Pulmonary Disease) which is one of the leading causes of disability and mortality worldwide. This project will design and develop a prognostic COPD healthcare management system which is a sustainable clinical decision-support system to reduce the number of readmissions by identifying those patients who need preventive interventions to reduce the probability of being readmitted. Based on patient’s clinical records and discharge summary, our system would be able to determine the readmission risk profile of patients treated for COPD. Suitable interventions could then be initiated with the objective of providing quality and timely care that helps prevent avoidable readmission. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2014. / FAU Electronic Theses and Dissertations Collection
626

Strength and durability of fly ash-based fiber-reinforced geopolymer concrete in a simulated marine environment

Unknown Date (has links)
This research is aimed at investigating the corrosion durability of polyolefin fiber-reinforced fly ash-based geopolymer structural concrete (hereafter referred to as GPC, in contradistinction to unreinforced geopolymer concrete referred to as simply geopolymer concrete), where cement is completely replaced by fly ash, that is activated by alkalis, sodium hydroxide and sodium silicate. The durability in a marine environment is tested through an electrochemical method for accelerated corrosion. The GPC achieved compressive strengths in excess of 6,000 psi. Fiber reinforced beams contained polyolefin fibers in the amounts of 0.1%, 0.3%, and 0.5% by volume. After being subjected to corrosion damage, the GPC beams were analyzed through a method of crack scoring, steel mass loss, and residual flexural strength testing. Fiber reinforced GPC beams showed greater resistance to corrosion damage with higher residual flexural strength. This makes GPC an attractive material for use in submerged marine structures. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2013.
627

Avaliação da dose glandular e qualidade de imagem de pacientes submetidas a mamografias com processamento de imagem digital / EVALUATION OF MEAN GLANDULAR DOSE AND IMAGE QUALITY OF PATIENTS UNDERGOING MAMMOGRAPHY WITH DIGITAL IMAGE PROCESSING

Marcio Alves de Oliveira 30 August 2011 (has links)
Nenhuma / O câncer de mama é, nos dias de hoje, uma das maiores causas de morte entre as mulheres em todo o mundo, pois muitas vezes não são diagnosticados precocemente. Só no Brasil foram estimados, em 2010/2011, mais de 49 mil novos casos de câncer de mama. Por este motivo, a mamografia cresceu significativamente nos últimos anos. Porém, a mamografia é uma técnica de diagnóstico por imagem que necessita de um cuidado especial, pois radiografias sem qualidade adequada podem ocasionar um falso diagnóstico e, além disso, acarretar a necessidade de repetição do exame, aumentado a dose de radiação na paciente e o risco à indução de novos cânceres. Portanto, é necessário avaliar as doses em mamografia, pois estas devem ser mantidas tão baixas quanto possível, sem reduzir a elevada qualidade de imagem necessária para a detecção precoce do câncer de mama. Neste sentido, este estudo teve como objetivo, avaliar a dose glandular média e qualidade da imagem de pacientes submetidos a exames de rotina em mamografia com sistema de processamento digital na cidade de Belo Horizonte-MG. Para isso, foram selecionados dois serviços com sistemas de processamento digital distintos (FUJI e KODAK). Nestes foram avaliados qualidade de imagem clínica e dose glandular média a que as pacientes são submetidas. Como resultado, foi obtido para o serviço FUJI uma dose média de 1,82 mGy e 2,07 mGy 3,72% para os posicionamentos craniocaudal (CC) e médio lateral oblíqua (MLO), respectivamente. Enquanto que para o serviço KODAK as médias foram de 2,53 mGy e 2,85 mGy 3,72% para os posicionamentos CC e MLO, respectivamente. Portanto, conclui-se que os valores obtidos nesta pesquisa se apresentaram de 50 a 85% acima dos níveis de referência determinados por protocolos internacionais calculados com 50 mm de polimetilmetacrilato (PMMA), que podem estar superestimando a dose para baixas espessuras de mama e subestimando para altas espessuras. / Breast cancer is nowadays one of the biggest killers of women worldwide as they often are not diagnosed early. In Brazil was estimated in 2010/2011, more than 49 000 new cases of breast cancer. For this reason, the mammogram has increased significantly. However, mammography is a technique that requires special care, because poor quality images can cause a false diagnosis, and cause the need for repeat testing, increasing the radiation dose to the patient and the risk to the induction of new cancers. Therefore, it is necessary to evaluate the doses in mammography, as they should be kept as low as possible without reducing the image quality required for the early detection of breast cancer. Thus, this study aimed to evaluate the average glandular dose and image quality of patients undergoing routine screening mammography to digital processing system in the city of Belo Horizonte-MG. To this end, we selected two services with different digital processing systems (Fuji and Kodak). In these image quality were evaluated clinically and average glandular dose that patients are subjected. As a result, the FUJI service was obtained an average dose of 1.82 mGy and 2.07 mGy for the positions craniocaudal (CC) and oblique (MLO), respectively. While Kodak service, the averages were 2.53 mGy and 2.85 mGy for the CC and MLO positions, respectively. Therefore, we conclude that the values obtained in this research were presented from 50 to 85% above the limits set by international protocols calculated with polymethylmethacrylate (PMMA), which may be overestimating the dose to lower breast thickness and underestimated for high thicknesses.
628

Análise da Qualidade Físico-Química dos Medicamentos Enalapril e Sinvastatina Manipulados em Farmácias Magistrais de Belo Horizonte - Minas Gerais

Tatiana Cristina Bomfim Gomes 30 April 2013 (has links)
Nenhuma / A crescente expansão do setor magistral associada aos diversos relatos sobre os desvios na qualidade de medicamentos manipulados demonstram a necessidade de verificação da qualidade, segurança e eficácia desses produtos. Neste trabalho, análises físico-químicas foram realizadas para avaliação da qualidade de algumas cápsulas manipuladas de enalapril e sinvastatina, adquiridas em cinco farmácias magistrais de Belo Horizonte/MG. Entre as análises realizadas estão os ensaios farmacopeicos de aspecto, identificação, determinação de peso, teor, compostos relacionados e uniformidade de doses unitárias, e, também foi realizada a análise por ativação neutrônica para determinação de impurezas inorgânicas nos medicamentos amostrados. Para os ensaios farmacopeicos, 60% das amostras foram insatisfatórias. Os teores individuais das cápsulas amostradas para o ensaio de uniformidade de doses unitárias variaram entre 0% e 136,2%. Este ensaio é importante na avaliação da qualidade, a qual influencia a segurança e a eficácia do tratamento medicamentoso, uma vez que permite verificar se o medicamento contém a dose adequada e necessária ao sucesso farmacoterapêutico. Por outro lado, subdosagens podem levar a redução ou ausência de resposta terapêutica desejada e, superdosagens podem propiciar o aparecimento de efeitos indesejáveis e até tóxicos. A concentração de impurezas inorgânicas foi considerada relativamente pequena. Entretanto, a ausência de limites específicos para alguns elementos químicos em medicamentos dificulta uma melhor discussão. Além disso, estudos adicionais devem ser realizados para a avaliação da exposição crônica a baixas concentrações de impurezas inorgânicas, uma vez que os medicamentos podem ser utilizados continuamente, e, outras fontes de exposição também devem ser consideradas a fim de se avaliar o risco. Os problemas relacionados à qualidade e segurança dos medicamentos manipulados ainda são realidade no país e revelam um grave problema de saúde pública, principalmente quanto à falta de uniformidade entre as doses unitárias dos medicamentos. Sugere-se que as autoridades competentes a vigilância sanitária desses produtos, proponham mudanças na fiscalização e melhorias na legislação vigente, uma vez que as análises requeridas pela legislação não são suficientes para garantir a qualidade dos medicamentos dispensados nas farmácias magistrais. / The increasing expansion of compounding pharmacy associated with several reports on variances in the quality of compounded drugs demonstrates the need for verification of quality, safety and efficacy of these products. In this work, physical and chemical analyzes were performed to evaluate the quality of some capsules manipulated enalapril and simvastatin, acquired in five pharmacies in Belo Horizonte /Brazil. Among the analyzes are pharmacopoeial tests for appearance, identification, determination of weight, content, related compounds and uniformity of dosage units, and was also performed neutron activation analysis for the determination of inorganic impurities in drugs sampled. The results showed that 60% of the samples were unsatisfactory for pharmacopoeial tests. The contents of the capsules sampled for individual testing unit dose uniformity between 0% and 136.2%. This test is important in evaluating the quality, which influences the safety and efficacy of drug treatment, since it allows you to check if the product contains the proper dosage and necessary for successful pharmacotherapy. On the other hand, underdosing can lead to reduced or absent desired therapeutic response, and overdoses can provide an undesirable effects and even toxic. The concentration of inorganic impurities was considered to be relatively small. However, no specific limits for some chemical elements in medicine hamper a better thread. In addition, further studies must be performed to assess chronic exposure to low concentrations of inorganic impurities, since drugs can be continuously used, and other sources of exposure must also be considered in order to evaluate the risk. The problems related to the quality and safety of compounded drugs are still reality in the country and reveal a serious public health problem, especially regarding the lack of uniformity between the unit doses of medications. It is suggested that the competent authorities to sanitary products, propose changes in supervision and improvements in legislation, since the analysis required by the law, are not sufficient to ensure the quality of drugs dispensed in pharmacies.
629

Estabelecimento de requisitos de desempenho em dosimetria e proteção radiológica nos serviços de mamografia digital de Minas Gerais / Establishment of performance requirements in dosimetry and radiation protection in digital mammography facilities digital in the state of Minas Gerais

Sabrina Donato da Silva 23 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Segundo dados do Cadastro Nacional de Estabelecimentos de Saúde (CNES), o Estado de Minas Gerais possui aproximadamente 477 mamógrafos em uso. Destes, estima-se que em torno de 200 são digitais utilizando, principalmente, sistemas de radiografia computadorizada (CR) ou radiografia direta (DR). A mamografia é insubstituível no diagnóstico e detecção precoce do câncer de mama, principal causa de morte entre mulheres no mundo. Um alto padrão de qualidade da imagem, aliada com uma dose tão baixa quanto razoavelmente exequível, são essenciais para esta detecção precoce de forma segura, levando a necessidade de controle de qualidade através do processo de otimização dos procedimentos. Dentro deste contexto este estudo teve como objetivo determinar a dosimetria e a qualidade da imagem em 72 combinações mamógrafo/CR e DRs em 68 serviços de mamografia do Estado de Minas Gerais, o que corresponde aproximadamente 14% do total de mamógrafos atualmente em uso no Estado de Minas Gerais e a cerca de 34% dos mamógrafos digitais em uso (CRs e DRs). O teste que avalia a linearidade da resposta do detector mamógrafico atendeu aos critérios de desempenho especificados pela Sociedade Espanhola de Física médica em 85% dos equipamentos avaliados. Porém dos serviços que apresentaram não conformidade nesse quesito apenas dois apresentaram menos de quatro anos de uso do mamógrafo. Possivelmente o tempo de utilização dos mamógrafos esteja relacionado a não conformidade apresentada por esses serviços. A relação contraste ruído mostrou-se ser um ponto crítico na cadeia de produção da imagem em sistemas digitais, principalmente para maiores espessuras de acrílico. Mais da metade dos serviços avaliados nessa pesquisa obtiveram um bom desempenho na relação sinal ruído (SNR), e na avaliação da imagem através do simulador de contraste e detalhe CDMAM. Em relação ao ruído da imagem a maioria dos serviços ficaram não conformes. Na avaliação da dose glandular média realizada com simuladores de mama, a média geral dos valores de doses obtidos ficaram dentro dos limites considerados aceitáveis na literatura, para a maioria das espessuras simuladas de mama. Porém os resultados obtidos nesse teste são preocupantes, pois a maioria dos sistemas digitais avaliados ficaram não conformes nesse quesito em pelo menos uma espessura de acrílico avaliada, e além disso houve um aumento considerável da dose glandular média em comparação a medidas anteriores realizadas no Estado de Minas Gerais. Já na comparação da dose glandular média entre sistemas CR e DR os sistemas DR apresentaram doses consideravelmente menores para maiores espessuras, em comparação com os sistemas CR. Em relação à comparação entre avaliações subsequentes a amostra seguiu o comportamento geral dos serviços avaliados nesta pesquisa, com exceção da SNR que apresentou um pior desempenho entre as avaliações subsequentes e o ruído, que apesar do baixo índice de conformidade obteve uma melhora entre uma avaliação e outra. Apesar dos potenciais benefícios que podem ser alcançados com o uso do sistema CR e DR, o emprego dessa tecnologia precisa ser revisto e otimizado para que possa oferecer imagens de qualidade utilizando a menor dose possível de radiação. / According to the National Registration of Health Establishments (CNES), there are approximately 477 mammographs operating in the state of Minas Gerais, of which, roughly estimating, 200 are digital apparatus using mainly computerized systems of radiography (CR) or direct radiography (DR). Mammography is irreplaceable in the diagnosis and early detection of breast cancer, the main cause of death in women worldwide. A high standard of image quality coupled with a dose as low as reasonably practicable, are essential for early detection of this disease with safely, leading to the need for quality control through optimization of process procedures. Within this context, this study aimed to determine dosimetry and image quality on 72 mammography combinations / CR and DR in 68 mammography services in the State of Minas Gerais, which represents approximately 14% of mammography units currently in use in the State of Minas Gerais and about 34% in use of digital mammography (CRs and DRs). The test evaluates the linearity of response of the detector mammographic met the performance criteria specified by the Spanish Society of Medical Physics in 85% of evaluated equipment. However, the services they showed non-compliance in this regard, only two were less than four years of use of mammography. Possibly the time of use of mammography is related to noncompliance by these services. The contrast noise ratio proved to be a critical point in the production chain image in digital systems, especially for thicker acrylic. More than half of the services evaluated in this study showed good performance in signal noise, and image evaluation by the phantom contrast and detail CDMAM. Regarding the image noise, most services were non-compliance. In evaluating the average glandular dose with breast phantom, the overall average dose values obtained were within acceptable limits in the literature for most of the simulated breast thicknesses. However the results of that test are troubling, since most digital systems evaluated were non-compliant in this regard at least one thick acrylic evaluated, and in addition there was a considerable increase in the average glandular dose compared to previous measurements performed in the State of Minas Gerais. In comparison between the average glandular dose in CR and DR systems, the DR systems showed significantly lower doses for greater thickness as compared with the CR systems. Regarding the comparison between subsequent reviews, the sample followed the general behavior of the services evaluated in this study, except the SNR had a worse performance between subsequent evaluations and noise, which despite the low level of compliance achieved an improvement between evaluation and other. Therefore, despite the potential benefits that can be attained with the use of the CR and DR systems, the employment of this technology has to be revised and optimised so that a better quality image can be achieved and the radiation dose reduced as much as possible.
630

INSPEÇÃO DE QUALIDADE NA SEPARAÇÃO DE PEDIDO: UM ESTUDO DE CASO EM UM CENTRO DE DISTRIBUIÇÃO.

Nobre, Silvio da Silva 14 April 2015 (has links)
Made available in DSpace on 2016-08-10T10:40:26Z (GMT). No. of bitstreams: 1 SILVIO DA SILVA NOBRE.pdf: 2654031 bytes, checksum: 931855cb07ec68ce9752f099cbb3b45f (MD5) Previous issue date: 2015-04-14 / The Distribution Centers (DC) has embarked on a major role in the supply chain, to the extent that manage much of logistics that is implemented and controls the storage from its origin to its final point. Among the processes of a CD, is the shipment of product for subsequent separation. Distribution Centers implement the fractional separation (rack flow) have constantly problems conference output products, waste and increasing the quality of decreasing process. This work aims to analyze the quality of separation and inspection of rack flow of products on a CD in order to ensure the quality of delivery to the final consumer. One high error rate in the separation process and also inspection of products and proposed an alternative in the inspection process was detected for identify errors and correct them. The results showed that the proposed process and analyzed, based on a precision scale, decreased the return of errors and identified the inspection errors in order to practically zeroing them. In addition, based on the results, analyzed and proposed a modification of the separation process. / Os Centros de Distribuição (CD) vem empenhando um papel importante na cadeia de suprimentos, na medida que gerenciam grande parte de logística que é implementada e controla o armazenamento desde sua origem até ao seu ponto final. Dentre os processos de um CD, encontra-se o de separação de produtos para posterior expedição. Centros de Distribuição que implementam a separação fracionada (flow rack) apresentam, constantemente, problemas de conferência de produtos de saída, aumentando o desperdício e dminuindo a qualidade do processo. Este trabalho tem como objetivo analisar a qualidade da separação e inspeção dos produtos do flow rack em um CD, a fim de garantir a qualidade da entrega para o consumidor final. Foi detectado um alta taxa de erros no processo de separação e também de inspeção dos produtos e proposta uma alternativa no processo de inspeção para indentificar os erros e corrigi-los. Os resultados obtidos demonstraram que o processo proposto e analisado, baseado em uma balança de precisão, diminuiram os erros de devolução e identificaram os erros de inspeção de forma a praticamente a zerá-los. Além disto, baseados nos resultados, analisada e proposta uma modificação do processo de separação.

Page generated in 0.0633 seconds