• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 757
  • 687
  • 90
  • 62
  • 39
  • 39
  • 32
  • 26
  • 11
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 2123
  • 2123
  • 661
  • 659
  • 357
  • 184
  • 183
  • 180
  • 172
  • 159
  • 144
  • 142
  • 117
  • 116
  • 116
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
631

Implantação de um programa de controle de qualidade em equipamentos de raios x por meio de medidores não invasivos / Establishment of an X radiation equipment quality control programme using non invasive meters

Rodrigo Ferreira de Lucena 14 September 2010 (has links)
O objetivo desse trabalho foi estudar o comportamento do principal equipamento de raios X utilizado nos procedimentos do laboratório de calibração do IPEN, LCI, operado nos intervalos de tensão de 25 a 150 kV utilizando os medidores de tensão não invasivos DiavoltTM da PTW e do sistema de espectrometria ORTEC, modelo NOMAD-PLUS 92X para o estabelecimento de um programa de controle de qualidade. O medidor Diavolt foi utilizado para as medições de kerma no ar, tensão de pico e tensão de pico prático. As medições foram feitas variando parâmetros como, corrente elétrica, Qualidade de Radiação X para Radiodiag-nóstico, angulação do medidor e sua distância em relação ao ponto focal do aparelho de raios X. Os resultados encontrados foram comparados com dados encontrados na literatura. Com o sistema de espectrometria, foram gerados os espectros com a finalidade de determinar as tensões de pico relativas às tensões nominais escolhidas e caracterizar as Qualidades em Radiodiagnóstico determinadas anteriormente. O programa de controle de qualidade estabelecido possibilita o controle do funcionamento tanto dos instrumentos de medição (câmaras de ionização, medidor de tensão e corrente e espectrômetro), bem como do sistema de radiação X. Neste trabalho também foi sugerida a periodicidade de realização de cada um dos testes. / The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model DiavoltTM, and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests.
632

Determinação de Sn(II) por polarografia: aplicação no controle de qualidade de reagentes liofilizados para radiodiagnóstico / Polarographic determination of Sn(II): application in the quality control of radiopharmaceutical reagents

Lugon, Marcelo di Marcello Valladão 11 July 2008 (has links)
Cloreto estanoso (SnCl2.2H2O) é o composto mais utilizado na redução do íon pertecnetato (TcO4-), obtido pela eluição do gerador, para a marcação de reagentes liofilizados para radiodiagnóstico. Estes reagentes liofilizados contêm um ligante, cloreto estanoso, e diferentes excipientes. Muitos métodos analíticos para a determinação de estanho não conseguem distinguir entre os íons estanoso (Sn(II)) e estânico (Sn(IV)) em soluções. Os dois métodos, descritos na literatura, para determinação seletiva de Sn(II) são análise titrimétrica e polarografia. O método mais confiável descrito para a quantificação do íon estanoso é a polarografia (voltametria) e pode ser utilizado para a determinação em concentrações de mg e g de Sn(II) e Sn(IV) (0,06-1,0 mg), com boa seletividade. Foi realizada análise titrimétrica, para quantificação de Sn(II), na matéria-prima e em 3 lotes consecutivos de 9 reagentes liofilizados produzidos pelo IPEN-CNEN/SP, utilizando-se sulfato cérico 0,1 mol L-1, diluído 10 vezes e iodo 0,05 mol L-1, diluído 10 vezes, como soluções titulantes. Polarografia por pulso diferencial foi utilizada com configuração convencional composta por três eletrodos: eletrodo de trabalho de gota de mercúrio, eletrodo referência de Ag/AgCl (saturado com KCl) e eletrodo auxiliar de platina. O intervalo de potencial analisado foi de -250 a -800 mV e o pico atribuído à redução de Sn(II) foi encontrado em -370 mV em eletrólito suporte de H2SO4 3 mol L-1 e, para Sn(IV), -470 mV, em eletrólito suporte de HCl 3 mol L-1. Para retirada do oxigênio da solução na cela polarográfica utilizou-se nitrogênio 5.0 por 5 minutos, antes e após cada introdução de amostra. Para determinação de Sn(IV) foi feita a oxidação do Sn(II), por adição de peróxido de hidrogênio, em 37 ± 5 ºC, por 5 minutos, seguida de purga com nitrogênio, e análise. A análise polarográfica desenvolvida mostrou-se adequada para a determinação de Sn(II), na presença de Sn(IV), e de estanho total nos kits radiofarmacêuticos estudados. / Stannous chloride (SnCl2.2H2O) is the major compound used for reduction of generator-derived 99mTc-pertechnetate in cold kits for on site preparation of 99mTc-radiopharmaceuticals. These cold kits usually contain a ligand, stannous chloride, and different additives. Various techniques were described for tin determination, but they cannot distinguish between stannous (Sn(II)) and stannic (Sn(IV)) ions in solutions. The two methods described in literature for selective determination of Sn(II) are polarography and mass analysis (redox-titration). Polarography is a good selective method in the mg range as well as in the g range for Sn(II) and Sn(IV) (0.06-1,0mg). Titrimetric analysis was performed for quantification of Sn(II) in Sn(II) reagents and in 3 consecutive lots of 9 radiopharmaceutical cold kits produced by IPEN-CNEN/SP, using Ce(SO4)2.4H2O 0.1 mol L-1, diluted 10 times and, I2 0.05 mol L-1, diluted 10, as a titrant solution. Differential pulse polarography was chosen with a conventional three-electrode configuration consisting of a static mercury drop electrode, an AgCl/Ag (saturated KCl) reference electrode and a platinum wire auxiliary electrode. The potential was swept from 250 to 800 mV and the current (A) was measured at 370 mV and 470 mV potentials for Sn(II) in H2SO4 3 mol L-1 and Sn(IV) in HCl 3 mol L-1, respectively. The supporting electrolytes were deaerated during 5 min with 5.0 nitrogen gas before and after each sample addition. For total tin determination the oxidation of tin (II) was carried out in the same vial, by adding H2O2 at 37 ± 5 ºC, for 5 min to quantify tin (IV). The developed polarographic method showed to be adequate to quantify tin (II), in the presence of tin (IV), in analyzed radiopharmaceutical cold kits.
633

Implementação e aceite de sistema de radioterapia de feixe modulado dinâmico com o uso de colimador secundário de múltiplas folhas / Commisioning and implantation of the dynamic intensity modulated radiation therapy using secondary multi-leaf collimator (MLC)

Cecilio, Paulo José 14 October 2008 (has links)
A radioterapia de feixe de intensidade modulada (IMRT) no seu modo dinâmico é uma forma de radioterapia tri-dimensional (3D), na qual modula-se um feixe de forma a obter-se a irradiação com campos que possuem perfil variável. Os campos são gerados por um sistema de otimização matemático e transformado em seqüências de movimento ou abertura de lâminas dos colimadores terciários de múltiplas folhas (MLC) ou feixe colimado helicoidal, reproduzindo a fluência de radiação adequada. No processo o operador atribui valores limitantes de dose ao alvo e aos órgãos de risco circunvizinhos para que o sistema de planejamento inverso realize a otimização possível. Após a aprovação do plano de tratamento o mesmo deve ser conferido, através de um controle de qualidade (CQ), onde são verificadas as doses que deverão ser administradas ao paciente, comprovando-se as doses obtidas e aprovadas no plano do sistema de planejamento (SPC). Para este controle os mesmos feixes e campos são medidos em termos de dose absorvida e perfis, através de dosimetria na qual comprova-se que não há erro físico ou dosimétrico no plano que irá tratar o paciente com diferença aceitável de até 5%, também utilizada como tolerância para a aprovação dos 460 casos avaliados nesta tese. Foram apresentados as metodologias para a aceitação no primeiro serviço a utilizá-la no Brasil e os testes de controle de qualidade de dois serviços de radioterapia, desde agosto de 2001 à maio de 2006 e no outro serviço de outubro de 2007 a maio de 2008, com controle de qualidade que permitiram os respectivos tratamentos clínicos com dados de 4 anos, ou seja, 460 casos com 3935 campos de tratamento verificados individualmente por dosimetria. Isto possibilitou o aperfeiçoamento da metodologia e garantia da qualidade nos tratamentos de IMRT dinâmico destes pacientes. / The intensity modulated radiation therapy (IMRT) is a type of radiation therapy using dynamic sliding window which modulated the beamlets of each field which are thus obtained as a variable profile. The multiple fields are obtained by mathematic optimization in special treatment planning system. In this way, the resulted field is generated by leaf sequencing using the multi-leaf collimator (MLC) or helicoidally beam. The optimization is an interactive process with operator and planning system where the dose prescription to target and dose limit for organ of risk are inserted to obtain the acceptable beam fluence and this process is named as inverse planning. The planning approved by physician should checked by means of dosimetry in order to assure the correct dose delivery; this action is the main task of a quality control (QC) program. The QC is performed by measurements of total absorbed dose and profile for each field planned for the patient. The acceptance level is 5% for total dose and was used for all 460 cases and 3935 fields analyzed between August 2001 to May 2006 at Albert Einstein Hospital and October 2007 to May 2008 at the Centro Infantil Dr. Boldrini. This work performs an analysis of the QC of treatments plans for all patients treated with IMRT. During four years the methodologies were frequently improved and upgradated for each tumor site and could thus be assured for the required quality of all treatments with dynamic IMRT.
634

Estudo e determinação de fatores de influência das dimensões dos frascos de radiofármacos utilizados no IPEN para calibração de ativímetros / Study and determination of the influence factors of the radiopharmaceutical vials dimensions used for activimeter calibration at IPEN

Martins, Elaine Wirney 25 October 2010 (has links)
A eficiência e a segurança de uma prática de medicina nuclear dependem, entre outros fatores, de um programa de controle de qualidade, principalmente no que diz respeito à utilização de medidores de atividade de radionuclídeos (ativímetros). Dentre as maiores fontes de erro nas medidas realizadas com um ativímetro estão: a espessura, o tamanho e o volume do frasco que contém o radiofármaco, considerando que um ativímetro típico tem a sua resposta reconhecidamente dependente do frasco utilizado. O propósito desse trabalho foi implantar um programa de controle de qualidade além de estabelecer fatores de correção referente à geometria do frasco de vidro para distribuição de radiofármacos e calibração de ativímetros, considerando que o Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui um Sistema Padrão Secundário NPL-CRC radionuclide calibrator, fabricado pela Southern Scientific, composto por uma câmara de ionização tipo poço e um sistema de medida de corrente, com rastreabilidade ao National Physical Laboratory (NPL) e calibrado com um frasco de vidro tipo P6 que possui dimensões diferentes dos utilizados pelo IPEN. Foram testados os radiofármacos 67Ga, 131I, 201Tl e 99mTc, todos produzidos pelo IPEN. Os resultados demonstraram uma variação de até 22% para o radiofármaco 201Tl, sendo que a menor variação foi encontrada para o 131I (2,98%). Os fatores de correção encontrados devem ser incorporados na calibração rotineira dos ativímetros. / The efficiency and safety of the nuclear medicine practice depend, among others factors, of a quality control programme, mainly related to the use of the nuclide activity meters (activimeter). One of the most important sources of errors in the activimeter measurements is the thickness, size and volume of the vial that contains the radiopharmaceutical considering that a typical activimeter has its response dependent of the vial used. The objective of this work was to establish a quality control programme and the correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration, considering that the Calibration Laboratory of Instrumentos (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN) has a NPL-CRC Secondary Standard Radionuclide Calibrator System, manufactured for the Southern Scientific plc, compound by an ionization chamber well type and a current measurement system, with traceability to National Physical Laboratory (NPL) and calibrated with a P6 vial type with different dimensions of the one used for the IPEN. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc, had been tested using the two different vials. The results shown a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters.
635

Identificação de planta medicinal baseada em espectrocospia e lógica fuzzy. / Signature of medicinal plant using spectroscopy and fuzzy logic.

Severo, Rosane Beatriz Oliveira 14 December 2009 (has links)
A presente tese de doutorado discorre sobre o método da espectroscopia na região do Infravermelho Próximo, usando Transformada de Fourier (IVP-TF), aplicada à identificação de plantas medicinais, método de análise química qualitativa, que se propõe para o controle de qualidade de fitoterápicos. É apresentado, também, um método computacional, implementado para realizar esta identificação, utilizando modelo e lógica nebulosos (fuzzy). Remete-se a discussão da espectroscopia IVP-TF como um método rápido e de baixo custo, para taxonomia de plantas medicinais brasileiras, bem como promove-se a comparação dos resultados obtidos nos diferentes métodos utilizados. / This doctoral thesis is about the method of Near Infrared spectroscopy using Fourier transform (FT-NIR), applied to identification of medicinal plants, method of the chemical analysis qualitative, which is proposed to the quality control of herbal medicines. It is presented, also, a computational method, implemented to make this identification using fuzzy logic model. Refers to discussion of FT-NIR spectroscopy as a rapid method with low cost for taxonomy of Brazilian medicinal plants, and makes comparison of results obtained in the different methods used.
636

Método polarográfico na determinação da viabilidade da vacina BCG liofilizada / Polarographic method for determining the viability of the lyophilized BCG vaccine

Malucelli, Maria Ivette Carboni 06 August 1991 (has links)
Tendo em vista os vários problemas envolvendo a metodologia correntemente utilizada para a determinação da viabilidade no controle de qualidade da vacina BCG liofilizada, foi levado a efeito um estudo a respeito do assunto. Foi procedido um estudo de métodos alternativos a serem empregados em procedimentos de controle de qualidade da vacina BCG liofilizada. Com esse objetivo foi desenhado e construído um polarógrafo de eletrodo de oxigênio constituído de eletrodo de platina e o de referência de Ag-AgCl embutido em peça única e ainda dotado de sensor de temperatura, com circuito eletrônico permitindo a medida de consumo de oxigênio. Levou-se a efeito, então, estudo comparativo de viabilidade de vacina BCG liofilizada pela medida polarográfica de consumo de oxigênio em comparação à manométrica pelo clássico método de Warburg e o método de contagem de colônias (UFC). A análise de 66 diferentes lotes de vacina BCG liofilizada produzidas pelo Instituto Butantan, São Paulo, e pela Fundação Ataulpho de Paiva, Rio de Janeiro, demonstrou que a técnica polarográfica revelou ser altamente reprodutível e muito mais conveniente que os métodos manométrico e de contagem de colônias. Verificou-se que entre o método polarográfico e o manométrico e UFC os resultados da regressão linear mostraram correlação positiva de alta intensidade e significante ao nível de a= 0,05, permitindo indicar o método polarográfico descrito, como procedimento de escolha para operações de controle de qualidade em laboratórios de produção de vacina BCG bem como em Unidades de Saúde, para determinações adequadas de viabilidade de lotes de vacinas, a serem utilizadas para fins de imunização. / Considering the several problems regarding the procedures currently employed in the assays o f the control of quality, and the viability of the freeze-dried BCG vaccines, a study on various methods used for this purpose was carried out. Aiming to introduce a much more suitable, sensitive and less time consuming method than the classic Warburg technique and the colony count test (CFU) bacteriological procedure, currently used, a new oxygen electrode polarograph was designed with the aim of employing it for the study of the viability of the freeze-dried BCG vaccine. This polarograph electrode was built in a single piece containing the platinun and theAgAgCl reference electrode besides a temperature sensor. By using this assembly a comparative study was carried on the viability of the freeze-dried BCG vaccine assayed by the polarographic method in comparison with the manometric and the CFU methods. The analysis of the viability of 66 different batches of freeze-dried BCG vaccines produced at the Butantan Institute, São Paulo, and at the Ataulpho de Paiva Foundation, Rio de Janeiro, demonstrated that the polarograpbic technique revealed to be highly reliable and much more convenient than both the manometric and the CFU methods: it has been found out that between the polarographic and the manometric and the CFU, the linear regression sbowed a high intensity positive correlation and significant at the level of a = 0,05. In this way, the polarographic method could be considered as a choice method for the control of quality procedure as well as for the establishment of the viability of the batches of vaccines to be used for human immunization in Units of the Health Department.
637

Controle da qualidade de projetos de edificações / Quality control for building designs

Ulrich, Helen 02 March 2001 (has links)
Discussão sobre a qualidade de projetos para edificações, com o objetivo de colaborar para o desenvolvimento de um sistema de controle da qualidade dos mesmos. A introdução dos conceitos de qualidade e produtividade no setor da construção civil é abordada segundo os princípios e teorias da Engenharia de Produção, onde destaca-se a importância do papel do projeto como sistematizador de todas as informações necessárias à execução. A qualidade do projeto influi diretamente na eficiência de todas as fases do processo de produção de edificações, e seu efetivo controle determina o sucesso da atividade de projeto. São realizados estudos de caso junto a empresas construtoras e escritórios de projeto, buscando caracterizar a atividade de projeto e analisar iniciativas de melhorias, que, juntamente com a análise do referencial teórico abordado, servem como base para a proposição de diretrizes para o controle da qualidade de projetos de edificações. Conclui-se que a atividade de projeto é um dos gargalos da construção civil e que as iniciativas de melhorias em busca de qualidade desta atividade contribuem com a evolução do setor como um todo. / The quality of building designs is discussed, for the purpose of cooperate with the development of a quality control system for building designs. The introduction of quality concepts in construction is also discussed, in accordance with the principles and theories of Production Engineering. This work recognizes design activity as being the sole informative source essential to construction. The quality of the design process directly influences the efficiency of ali the phases of construction, and its effective control determines the design activity success. Some case studies were carried out, aiming to identify and characterize the design activity in construction enterprises and design offices as well as identifying initiatives of quality improvement. The results of these case studies along with a theoretical analysis form the basis to propose some guidelines for the quality control in building designs. It is concluded that design activity is one of the most important phases in building construction, and that initiatives to improve its quality will contribute to the evolution of the entire construction process.
638

Quality circles : a new experience for Hong Kong.

January 1982 (has links)
by Hsia Sih-ming, Chang Chi-yuan. / Bibliography: leaves 93-97 / Thesis (M.B.A.)--Chinese University of Hong Kong, 1982
639

Status of implementation of quality management practices in Hong Kong.

January 1996 (has links)
by Wong Kwai Lin Christine. / Thesis (M.B.A.)--Chinese University of Hong Kong, 1996. / Includes bibliographical references (leaves 47-48). / ABSTRACT / TABLE OF CONTENTS / LIST OF FIGURES / LIST OF TABLES / ACKNOWLEDGMENT / Chapter / Chapter I. --- Introduction --- p.1 / Chapter II. --- Research --- p.3 / Exploratory Research --- p.3 / Literature Search --- p.4 / Quality Concepts --- p.4 / W. Edward Deming --- p.5 / Joseph Juran --- p.8 / Philip Crosby --- p.10 / Quality --- p.11 / ISO 9000 Series --- p.12 / The Malcolm Baldrige National Quality Award --- p.13 / Status of Promotion of Quality Management --- p.13 / Specific Research --- p.14 / Theoretical Basis --- p.15 / Descriptive Research --- p.17 / Data Collection Method --- p.18 / Method of Administration --- p.19 / Sample Design --- p.21 / Target Population --- p.21 / Sampling Frame --- p.21 / Sampling Procedure --- p.22 / Questionnaire Design --- p.22 / Part I - Company Demographics --- p.20 / Part II - Company Performance --- p.23 / Part III - Quality Improvement Techniques --- p.23 / Data Analysis --- p.24 / Response --- p.24 / Managerial Knowledge --- p.29 / Quality Performance --- p.30 / Financial Performance --- p.30 / Past Quality Performance --- p.30 / Market Place Environment --- p.31 / Corporate Support for Quality --- p.31 / Role of Management Leadership and Quality --- p.32 / Quality Data and Reporting --- p.33 / Strategic Quality Planning --- p.33 / Employees' involvement and Participation --- p.34 / Employees' Training --- p.34 / Feedback and Recognition of Employees' Performance --- p.35 / Employees' Relations --- p.36 / Product Service Design --- p.36 / Process Management --- p.36 / Supplier Quality Management --- p.37 / Role of Quality Department --- p.38 / Customer Feedback --- p.39 / Chapter III. --- SUMMARY OF FINDINGS --- p.40 / Difference between Manufacturing and Service Companies --- p.41 / Difference between Companies with without Separate Quality Department --- p.41 / Difference between Companies with or without Certification --- p.42 / Chapter IV. --- CONCLUSIONS --- p.44 / Chapter V. --- RECOMMENDATIONS --- p.46 / BIBLIOGRAPHY / Chapter APPENDIX 1 --- Sample Questionnaire / Chapter 2 --- Figures 2 to 18
640

Deadline-ordered parallel iterative matching with QoS guarantee.

January 2000 (has links)
by Lui Hung Ngai. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2000. / Includes bibliographical references (leaves 56-[59]). / Abstracts in English and Chinese. / Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Thesis Overview --- p.3 / Chapter 2 --- Background & Related work --- p.4 / Chapter 2.1 --- Scheduling problem in ATM switch --- p.4 / Chapter 2.2 --- Traffic Scheduling in output-buffered switch --- p.5 / Chapter 2.3 --- Traffic Scheduling in Input buffered Switch --- p.16 / Chapter 3 --- Deadline-ordered Parallel Iterative Matching (DLPIM) --- p.22 / Chapter 3.1 --- Introduction --- p.22 / Chapter 3.2 --- Switch model --- p.23 / Chapter 3.3 --- Deadline-ordered Parallel Iterative Matching (DLPIM) --- p.24 / Chapter 3.3.1 --- Motivation --- p.24 / Chapter 3.3.2 --- Algorithm --- p.26 / Chapter 3.3.3 --- An example of DLPIM --- p.28 / Chapter 3.4 --- Simulation --- p.30 / Chapter 4 --- DLPIM with static scheduling algorithm --- p.41 / Chapter 4.1 --- Introduction --- p.41 / Chapter 4.2 --- Static scheduling algorithm --- p.42 / Chapter 4.3 --- DLPIM with static scheduling algorithm --- p.48 / Chapter 4.4 --- An example of DLPIM with static scheduling algorithm --- p.50 / Chapter 5 --- Conclusion --- p.54 / Bibliography --- p.56

Page generated in 0.0416 seconds