31 |
Uni-axial behaviour of concrete-filled-steel-tubular columns with external confinementDong, Chunxiao, 董春宵 January 2013 (has links)
This thesis studies the uni-axial behaviour of circular double-skinned concrete-filled-steel-tubular (CFST) columns with external confinement in form of external steel rings. Particular attention is paid to the experimental behaviour of double-skinned CFST columns and theoretical model for evaluating the loadcarrying capacity of un- and ring-confined double-skinned CFST columns.
Experimental studies on circular double-skinned CFST columns with various spacing of confinement, concrete strength and hollow ratio were conducted and discussed comprehensively. The mechanical properties of double-skinned CFST columns such as elastic stiffness, elastic strength, load-carrying capacity and ductility are presented. From the result, it is found that the elastic stiffness, elastic strength, load-carrying capacity and ductility are enhanced by installing the external steel rings to the outer tube as external confinement. To verify the effectiveness of external steel rings, the Poisson’s ratios of the double-skinned CFST columns are listed and found to be similar to that of concrete so that a perfect bonding is maintained. To emphasis the excellent performance of double-skinned CFST columns with external rings under uni-axial compression, the load-carrying capacity, elastic strength and elastic stiffness are compared to those of single-skinned CFST columns and reinforced concrete columns.
To fill up the gap that no design model is provided in Eurocode 4 (EC4) for confined double-skinned CFST columns, a theoretical model based on the force equilibrium condition is proposed for evaluating the load-carrying capacity of both un- and ring-confined double-skinned CFST columns. The model takes into account the composite action between the steel tubes and core concrete. To verify the proposed model, numerous test results obtained by the author and other researchers are used for comparing the theoretical results.
According to the above theoretical model above, a parametric study is carried out to investigate the effect of various geometry and material properties on the load-carrying capacity of double-skinned CFST columns. The confining pressure is expressed in terms of geometry and material factors. A simplified design formula is proposed to facilitate the preliminary design of double-skinned CFST columns with and without external confinement. / published_or_final_version / Civil Engineering / Master / Master of Philosophy
|
32 |
Experimental investigation of steel tubed reinforced concrete columnsMachado, Rafael Ignacio 05 1900 (has links)
No description available.
|
33 |
Behavior of bolted beam-to-column T-stub connections under cyclic loadingSmallidge, Jeffrey M. 05 1900 (has links)
No description available.
|
34 |
Cyclic behavior of shape memory alloy tendons and steel bolted t-stubs in beam-column connectionsHess, W. Gregory (Willard) 12 1900 (has links)
No description available.
|
35 |
Cast Steel Yielding Brace System for Concentrically Braced FramesGray, Michael G. 12 December 2012 (has links)
This thesis presents the development and validation of a high ductility seismic resistant steel brace connector called the Yielding Brace System (YBS) that improves the earthquake performance of steel braced frame buildings. The connector is comprised of two steel castings which dissipate seismic energy through flexural yielding of specially designed triangular yielding fingers. In this body of work, the need for such a system is presented along with a summary of previously developed steel castings for enhanced earthquake performance of building structures. The development of the YBS concept is then discussed in detail and equations are developed to predict the elastic and plastic response of a YBS connector based on the geometry of the yielding fingers. The low-cycle fatigue life of the cast steel material used for the yielding elements of the YBS is characterized based on the results of several cyclic, small-scale yielding fingers tests and a low-cycle fatigue life prediction model is derived. Following this, the design of a prototype connector for the second storey brace of a fictitious six storey sample building located in Los Angeles is presented. This design is conducted using the low-cycle fatigue prediction model, the response prediction equations and non-linear finite element analysis. Results of four full-scale prototype tests are then presented. Two of the tests are axial tests of the device alone, while the other two are full-scale braced frame tests. Finally, the design of a 12-storey sample building is presented. This building design is then evaluated via non-linear time-history analysis using the FEMA P-695 methodology. The results from these analyses are then discussed and compared to a similar study conducted on the same building designed with buckling restrained braces. This work shows that the Yielding Brace System is a highly ductile, seismic resistant brace that can be used as an alternative to the buckling restrained brace with the potential to provide a stiffer structure with increased ductility.
|
36 |
Cast Steel Yielding Brace System for Concentrically Braced FramesGray, Michael G. 12 December 2012 (has links)
This thesis presents the development and validation of a high ductility seismic resistant steel brace connector called the Yielding Brace System (YBS) that improves the earthquake performance of steel braced frame buildings. The connector is comprised of two steel castings which dissipate seismic energy through flexural yielding of specially designed triangular yielding fingers. In this body of work, the need for such a system is presented along with a summary of previously developed steel castings for enhanced earthquake performance of building structures. The development of the YBS concept is then discussed in detail and equations are developed to predict the elastic and plastic response of a YBS connector based on the geometry of the yielding fingers. The low-cycle fatigue life of the cast steel material used for the yielding elements of the YBS is characterized based on the results of several cyclic, small-scale yielding fingers tests and a low-cycle fatigue life prediction model is derived. Following this, the design of a prototype connector for the second storey brace of a fictitious six storey sample building located in Los Angeles is presented. This design is conducted using the low-cycle fatigue prediction model, the response prediction equations and non-linear finite element analysis. Results of four full-scale prototype tests are then presented. Two of the tests are axial tests of the device alone, while the other two are full-scale braced frame tests. Finally, the design of a 12-storey sample building is presented. This building design is then evaluated via non-linear time-history analysis using the FEMA P-695 methodology. The results from these analyses are then discussed and compared to a similar study conducted on the same building designed with buckling restrained braces. This work shows that the Yielding Brace System is a highly ductile, seismic resistant brace that can be used as an alternative to the buckling restrained brace with the potential to provide a stiffer structure with increased ductility.
|
37 |
Behaviour and design of cold-formed steel hollow flange sections under axial compressionZhao, Wen-Bin January 2006 (has links)
The use of cold-formed steel structures is increasing rapidly around the world due to the many advances in construction and manufacturing technologies and relevant standards. However, the structural behaviour of these thin-walled steel structures is characterised by a range of buckling modes such as local buckling, distortional buckling or flexural torsional buckling. These buckling problems generally lead to severe reduction and complicated calculations of their member strengths. Therefore it is important to eliminate or delay these buckling problems and simplify the strength calculations of cold-formed steel members.
The Hollow Flange Beam with two triangular hollow flanges, developed by Palmer Tube Mills Pty Ltd in the mid-1990s, has an innovative section that can delay the above buckling problems efficiently. This structural member is considered to combine the advantages of hot-rolled I-sections and conventional cold-formed sections such as C- and Z-sections (Dempsey, 1990). However, this structural product was discontinued in 1997 due to the complicated manufacturing process and the expensive electric resistance welding method associated with severe residual stresses (Doan and Mahendran, 1996). In this thesis, new fastening methods using spot-weld, screw fastener and self-pierced rivet were considered for the triangular Hollow Flange Beams (HFBs) and the new rectangular hollow flange beams (RHFBs). The structural behaviour of these types of members in axial compression was focused in this research project. The objective of this research was to develop suitable design models for the members with triangular and rectangular hollow flanges using new fastening methods so that their behaviour and ultimate strength can be predicted accurately under axial compression.
In the first stage of this research a large number of finite element analyses (FEA) was conducted to study the behaviour of the electric resistance welded, triangular HFBs (ERW-HFBs) under axial compression. Experimental results from previous researchers were used to verify the finite element model and its results. Appropriate design rules based on the current design codes were recommended. Further, a series of finite element models was developed to simulate the corresponding HFBs fastened using lap-welds (called LW-HFBs) and screw fasteners or spot-welds or self-piercing rivets (called S-HFBs). Since the test specimens of LW-HFBs and S-HFBs were unavailable, the finite element results were verified by comparison with the experimental results of ERW-HFB with reasonable agreement.
In the second stage of this research, a total of 51 members with rectangular hollow flanges including the RHFBs made from a single plate and 3PRHFBs made from three plates fastened with spot-welds and screws was tested under axial compression. The finite element models based on the tests were then developed that included the new fasteners, contact simulations, geometric imperfections and residual stresses. The improved finite element models were able to simulate local buckling, yielding, global buckling and local/global buckling interaction failure associated with gap opening as agreed well with the corresponding full-scale experimental results. Extensive parametric studies for the RHFBs made from a single plate and the 3PRHFBs made from three plates were undertaken using finite element analyses. The analytical results were compared with the predictions using the current design rules based on AS 4100, AS/NZS 4600 and the new direct strength method. Appropriate design formulae based on the direct strength method for RHFBs and 3PRHFBs were developed. This thesis has thus enabled the accurate prediction of the behaviour and strength of the new compression members with hollow flanges and paved the way for economical and efficient use of these members in the industry.
|
38 |
Seismic performance of wide flange beam to deep-column moment connections /Zhang, Xiaofeng, January 2004 (has links)
Thesis (Ph. D.)--Lehigh University, 2004. / Includes vita. In two parts. Includes bibliographical references (leaves 323-327).
|
39 |
Design of welded tubular connections basis and use of AWS code provisions /Marshall, Peter William. January 1992 (has links)
Originally presented as the author's Thesis (Ph. D.)--University of Kumamoto. / Includes bibliographical references and index.
|
40 |
Análise teórica e experimental de vigas mistas de aço e concreto e laje com vigotas pré-moldadas e lajotas cerâmicas em um pavimento tipo / Theorical and experimental analysis of composite steel and concrete beams and slabs made by precast elements with lattice and bricks on a frameBruno Eizo Higaki 11 December 2009 (has links)
As vigas mistas de aço e concreto são elementos estruturais que resultam da associação de um perfil de aço laminado, formado a frio ou soldado, e de uma laje de concreto podendo esta ser moldada in loco, pré-fabricada ou com forma de aço incorporada. A construção de vigas mistas com laje de vigotas pré-moldadas de concreto não é prevista pela norma brasileira de dimensionamento de elementos de aço NBR 8800:2008 e poucos estudos foram realizados até o momento. Geralmente, os estudos realizados sobre vigas mistas são feitos em modelos compostos por perfil de aço e uma faixa de laje denominada largura efetiva. Neste trabalho foi desenvolvido um estudo teórico e experimental de vigas mistas fazendo parte de um pavimento tipo. O objetivo principal foi o estudo do comportamento das vigas mistas pertencentes a um pavimento tipo quando submetidas a diferentes tipos de carregamentos, distribuídos e concentrados, verificação da formação de fissuras na laje e a importância de considerar uma faixa de laje maciça na região da largura efetiva sobre as vigas. A análise numérica foi realizada utilizando o pacote comercial ANSYS e por meio das expressões de cálculo fornecidas pela norma brasileira de aço e adaptações para consideração da pré-laje de concreto. Os resultados mostraram um bom desempenho das vigas mistas comparadas com a resistência de cálculo de acordo com as expressões fornecidas pela norma para vigas mistas com pré-laje de concreto e a importância da execução de uma faixa maciça na região da largura efetiva. / The composite steel and concrete beams are structural elements witch results of association by a hot rolled, cold formed or welded steel beam and concrete slab which can be made in site, precast or with steel deck. The design of composite beams made with slab made with precast type lattice joist isn\'t anticipated by the brazilian code and a few studies has been made up to now. Usually, the studies about composite beams are made with steel beam and a concrete\'s zone called a slab\'s effective width. In this work a teorical and experimetal studies were presented with a frame\'s composite beams. The aim of this work was investigate the behaviour when differents loads, distributed and concentrated, were apllied, find out if cracks appeared and the importance of design a solid slab on the effective width\'s regions. The theorical analysis made using the code ANSYS v.10.0 and with expressions of brazilian code for composite beams with precast slabs. The results have shown a good agreement with code\'s analitical models and teh importance of design a solid slab on the effective width\'s regions.
|