A statistical approach to the control of shunt reactive compensators

Siddig, Awad Ahmed January 1987 (has links)
No description available.
2

Microprocessor controlled VAR compensator

Hakim, Faiez Matti Yousif January 1985 (has links)
No description available.
3

Test characteristics and operation of surge arrester elements

Fuentes-Rosado, J. January 1993 (has links)
This Thesis presents the development of an empirical and simple computer model for a voltage response of a ZnO element The derived model consists of a linear capacitor and atime-varying resistance. The data necessary for the derivation of the model is collected from testing on three ZnO elements with three different linear circuits. The front times of the voltage responses of the ZnO elements range from nanoseconds to submicroseconds. The front times of the current impulses being used to produce the voltage impulses varies from nanoseconds to microseconds. The voltages having nanosecond front times are measured with attenuators and the voltages with sub-microsecond-front time with a capacitor divider. Currents associated with the nanosecond-front-time voltages are measured with a technique founded on transmission line concepts. Currents associated with the submicrosecond-front-time voltages are obtained with a current shunt The response time of the capacitor divider and of the current shunt fall outside the ranges of the ratios of front time to response times specified in the IEC standard. Distortion introduced by the measuring devices into the measured signals is investigated with computer simulation. Conical transmission lines were constructed to test the voltage response of a toroidal ZnO element to the nanosecond-front-time current impulses. Analysis of the voltage response to the current impulses with sub-and-microsecond-front times indicates that at the beginning of the response, of a ZnO element it behaves as an approximately linear capacitor and subsequently as a capacitor in parallel with a timevarying resistance. The turn-on of the resistive behaviour occurs at approximately the first current peak The discrete voltage relating to the first current peak is named here the threshold voltage. This discrete voltage also denotes the tum-off of the resistive behaviour on the wave tail. The values of the apparent capacitances and permittivities of the ZnO elements are obtained. The apparent permittivities of the three ZnO elements are similar. The computed and measured variations of the resistance show good agreement The simulated and computed voltage responses of a ZnO element also show good agreement Atoroidal ZnO element is tested with the nanosecond-front-time current impulses. Analysis of the voltage response and the current-impulse shape by q-v curves and comparison of the measured responses to those of lumped linear capacitors show that a)the response of the ZnO element is capacitive and b) the capacitor characteristic is quasilinear. The simulated and computed voltage responses show good agreement The deviation from linearity originates from both the limited response of the attenuators and mismatches between the conical transmission lines and the section of the coaxial cable of the used current generator. The voltage response of miniature ZnO elements (also tested with the nanosecond-front time current impulses) show resistive behaviour. This Thesis also presents the design, construction and operation of a measuring system based on Rogowski coils. The model used for the analysis of the measuring system is an extended version of an existing model of a Rogowski coil. The model being introduced here can account for the interaction of the Rogowski coil with the remainder of the measuring system. This is applied successfully to the measurement of an impulse current flowing through a ZnO element
4

The control of a voltage-sourced, invertor-fed synchronous machine

Chard, J. January 1988 (has links)
No description available.
5

AC voltage adjustment and controlled compensation of electrical power drives

Odiete, G. C. E. January 1986 (has links)
No description available.
6

Performance studies of a thyristor controlled reactor for arc furnace compensation using computer and laboratory models

Tang, C. K. K. January 1987 (has links)
No description available.
7

Modelling, evaluation and demonstration of novel active voltage control schemes to accomodate distributed generation in distribution networks

Fila, Maciej January 2010 (has links)
Voltage control in distribution networks is becoming more challenging due to the growing amount of distributed generation that is being connected to the distribution networks in addition to increasing load. The output of the distributed generation can radically change power flows and voltage profiles in distribution networks, creating conditions that adversely affect the performance of automatic voltage control schemes and in addition cause unacceptable voltage rise. On the other hand, inherent limitations and current operational policies of AVC schemes very often restrict the output of DG or even prevent its connection. This thesis investigates and analyses voltage control in terms of the shift from passive to active distribution networks. The thesis also reviews the performance of AVC schemes under varying load and generation output conditions, investigates effective utilisation of distribution network assets and methods to accommodate active voltage control schemes into existing infrastructure. A range of active voltage control and management schemes based on coordinated voltage control is presented and assessed. These schemes can be used to improve the voltage profile in distribution networks and increase their ability to accommodate distributed generation. The functionality of each scheme is assessed based on a number of factors such as the ability of the scheme to increase network capacity, reliability and accuracy. Simulation software to accurately evaluate the performance of an active voltage control scheme in a particular distribution network scenario is essential before the scheme can be deployed. Formal assessment of advanced AVC models and SuperTAPP n+ functionality is performed using simulation software as developed and presented in this thesis. The accuracy of the software results and performance of the SuperTAPP n+ scheme is validated based on network trials carried out in EDF Energy Networks.
8

Large-scale security constrained optimal reactive power flow for operational loss management on the GB electricity transmission network

Macfie, Peter January 2010 (has links)
The transmission of power across the GB transmission system, as operated by National Grid, results in inevitable loss of electrical power. Operationally these power losses cannot be eliminated, but they can be reduced by adjustment of the system voltage profile. At present the minimisation of active power losses relies upon a lengthy manually based iterative adjustment process. Therefore the system operator requires the development of advanced optimisation tools to cope with the challenges faced over the next decade, such as achieving the stringent greenhouse gas emission targets laid down by the UK government, while continue to provide an economical, secure and efficient service. To meet these challenges the research presented in this thesis has developed optimisation techniques that can assist control centre engineers by automatically setting up voltage studies that are low loss and low cost. The proposed voltage optimisation techniques have been shown to produce solutions that are secured against 800 credible contingency cases. A prototype voltage optimisation tool has been deployed, which required the development of a series of novel approaches to extend the functionality of an existing optimisation program. This research has lead to the development of novel methods for handling multi-objectives, contradictory shunt switching configurations and selecting all credible contingencies. Studies indicate that a theoretical loss saving of 1.9% is achievable, equivalent to an annual emissions saving of approximately 64,000 tonnes of carbon dioxide. A novel security constrained mixed integer non-linear optimisation technique has also been developed. The proposed method has been shown to be superior to several conventional methods on a wide range of IEEE standard network models and also on a range of large-scale GB network models. The proposed method manages to further reduce active power losses and also satisfies all security constraints.
9

A Lithium-ion Battery Charger

Xing, Hanwen, Liu, Xin January 2015 (has links)
Nowadays personal small electronic devices like cellphones are more and more popular, but the various batteries in need of charging become a problem. This thesis aims to explain a Lithium-ion charger which can control the current and voltage so that it can charge most kinds of popular batteries. More specifically, Li-ion battery charging is presented. The charging circuit design, simulation and the measurements will also be included.
10

Grid Fault Ride-through Capability of Voltage-Controlled Inverters for Distributed Generation Applications

Piya, Prasanna 06 May 2017 (has links)
The increased integration of distributed and renewable energy resources (DERs) has motivated the evolution of new standards in grid interconnection requirements. New standards have the requirement for the DERs to remain connected during the transient grid fault conditions and to offer support to the grid. This requirement is known as the fault ride-through (FRT) capability of the inverter-based DERs and is an increasingly important issue. This dissertation presents the FRT capability of the DERs that employ a voltage control strategy in their control systems. The voltage control strategy is increasingly replacing the current control strategy in the DERs due to the fact that it provides direct voltage support. However, the voltage control technique limits the ability of direct control over the inverter current. This presents a challenge in addressing the FRT capability where the problem is originally formulated in terms of the current control. This dissertation develops a solution for the FRT capability of inverters that use a voltage control strategy. The proposed controller enables the inverter to ride through the grid faults and support the grid by injecting a balanced current with completely controlled real and reactive power components. The proposed controller is flexible and can be used in connection with various voltage control strategies. Stability analysis of the proposed control structure is performed based on a new linear time-invariant model developed in this dissertation. This model significantly facilitates the stability and design of such control loops. Detailed simulation, real-time and experimental results are presented to evaluate the performance of the proposed control strategy in various operating conditions. Desirable transient and steady-state responses of the proposed controller are observed. Furthermore, the newly established German and Danish grid fault ride-through standards are implemented in this research as two application examples and the effectiveness of the dissertation results are illustrated in the context of those two examples.