• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6196
  • 104
  • 102
  • 101
  • 80
  • 78
  • 71
  • 57
  • 29
  • 11
  • 10
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 6446
  • 3308
  • 1312
  • 889
  • 876
  • 836
  • 744
  • 710
  • 676
  • 598
  • 569
  • 537
  • 502
  • 455
  • 402
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelo para priorização de diretrizes de combate a crises de abastecimento urbano de água / Model for priority guidelines for facing crisis of urban water supply

Silva, Welitom Ttatom Pereira da 10 December 2012 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2012. / Submitted by Liliane Simões (miix007@gmail.com) on 2013-04-08T12:55:54Z No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-04-08T14:57:45Z (GMT) No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / Made available in DSpace on 2013-04-08T14:57:45Z (GMT). No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / As situações de crise no abastecimento urbano de água, caracterizadas pela escassez da água e por prejuízos ambientais, sociais e à saúde da população, principalmente para a população de baixa renda, têm-se tornado algo muito comum em diversas regiões brasileiras. A pesquisa realizada tem o objetivo de apresentar uma contribuição para o planejamento do enfrentamento de crise no abastecimento urbano de água (CAUA). Para isso foi proposta uma combinação de técnicas de inteligência artificial e metodologias multicriteriais de apoio à decisão (MCDA). O desenvolvimento de ferramentas computacionais (software) para auxiliar o processo de tomada de decisão e a realização de um estudo de caso fazem parte do escopo metodológico da proposta da pesquisa. Os resultados encontrados foram os seguintes: o conhecimento de possíveis diretrizes de projeto para solução de casos de CAUA; o conhecimento de fatores influentes na CAUA; o desenvolvimento de um modelo híbrido de análise de decisão, denominado de CAUA- SAD, baseado nos princípios de similaridade vetorial, de sistemas baseados em conhecimento (sistemas especialistas) e na utilização das MCDA (métodos PROMETHEEII, TOPSIS e ELECTRE III). A avaliação da qualidade dos modelos desenvolvidos indicou um percentual de concordância de 56%, e que melhorias nos modelos podem ser obtidas por meio de refinamento nos dados de entrada, em termos de qualidade e de quantidade. As conclusões obtidas da pesquisa indicam que a abordagem adotada para o tratamento do problema pode ser considerada adequada. No entanto, problemas para a obtenção do conhecimento de especialistas humanos sugerem a continuidade dos estudos. ________________________________________________________________________________________ ABSTRACT / Crisis situations in urban water supply, characterized by water scarcity and by population health, social, and environmental damages, specially for the low-income population, have become very common in several Brazilian regions. The objective of this research is to contribute to the planning for facing crisis in urban water supply (CUWS).To achieving this goal, a combination of artificial intelligence techniques and Multiple Criteria Decision Aid (MCDA) was proposed. The development of computational tools (software) to assist the process of decision making and their application to a case study are parts of the scope of the research proposal. The following results were obtained in this research: knowledge of possible design guidelines for solving CUWS cases; knowledge of factors influencing CUWS; development of a hybrid model of decision analysis, called CUWS-SAD, based on the principles of vector similarity, knowledge-based systems (expert systems) and on the use of MCDA (PROMETHEE II, TOPSIS and ELECTRE III methods). The quality assessment of the developed models indicated concordance index of 56%, and that improvements in the models can be obtained through enhancement in the quality and quantity of the input data. The conclusions of the research indicate that the proposed approach for the problem treatment can be considered adequate. However, problems to attain knowledge of human experts suggest further investigations.
2

Avaliação da remoção de fitoplâncton e formação de trialometanos em águas de abastecimento em processo de tratamento por FAD, interoxidação e desinfecção com cloro

JUSTINO, F. F. 26 August 2010 (has links)
Made available in DSpace on 2018-08-24T22:53:11Z (GMT). No. of bitstreams: 1 tese_4362_.pdf: 2733607 bytes, checksum: ae4c4942e9fdfc938d3bd56d8eb306a0 (MD5) Previous issue date: 2010-08-26 / A presença de populações algais nos reservatórios torna mais problemática a operacionalidade dos sistemas de tratamento e pode causar impactos negativos na qualidade das águas distribuídas ao gerar sabores e odores na água e interferir no processo de clarificação. Além disto, uma das grandes preocupações ambientais e de saúde pública em lagos e represas e a floração de algas e cianobactérias produtoras de toxinas. Em águas de abastecimento, a matéria orgânica natural, as algas/microalgas e as cianobactérias e seus metabólitos, inclusive suas toxinas, são os principais precursores com os quais os halogênios reagem para formar subprodutos da cloração, entre estes os trialometanos. O processo de clarificação utilizando o sistema de flotação vem sendo utilizado para remoção de algas, cianobactérias e suas toxinas em substituição ou conjuntamente com os processos de decantação e filtração direta. Este estudo consistiu da avaliação, em escala de bancada, dos processos de coagulação e floculação com sulfato de alumínio, flotação por ar dissolvido (FAD), inter-oxidação com cloro, filtração em areia e desinfecção com cloro, com o objetivo de investigar a remoção de fitoplâncton e a formação de trialometanos em águas de abastecimento com presença de microalgas e cianobactérias. O estudo de coagulação com sulfato de alumínio resultou em regiões semelhantes de remoção (pH 6,3 e 6,5 e 25 a 35mg/L Al2(SO4)3) dos parâmetros cor aparente e cor real e turbidez para os períodos de seca (71%) e de chuvas (93%). Na otimização da flotação os resultados indicaram uma melhor remoção do material particulado (95%) e cor real (74%) na velocidade ascensional de 5cm/min. Os testes de inter-oxidação resultaram em baixa demanda de cloro, indicando a eficiência da flotação na remoção da matéria orgânica. A caracterização da água do manancial Duas Bocas mostrou qualidade de água satisfatória para águas de abastecimento no período observado. Na avaliação qualiquantitativa do fitoplâncton foram registrados 22 táxons, sendo a Classe Cyanophyceae a mais representativa em riqueza e em densidade relativa total nos dois meses de estudo, destacando o domínio das espécies Synechococcus nidulans e Anabaena sp. Esta última apresenta potencial de produção de neurotoxinas e hepatotoxinas, 9 dos 15 gêneros listados são mencionados como causadores de problemas operacionais como gosto, odor, colmatação dos filtros, entre outros. No estudo comparativo entre duas linhas de tratamento, apesar de um maior gasto com coagulante e alcalinizante, o tratamento 2 (30mg/L Al2(SO4)3 em pH 6,4) mostrou-se adequado nos dois meses estudados (maio e junho). A inter-oxidação apresentou baixa eficiência de remoção dos parâmetros cor aparente, turbidez e absorbâncias 254 e 665, nos tratamentos 1 e 2. O meio filtrante misto, composto com de grãos de areia de tamanho 1,20 a 0,60mm (70%) e 0,60 a 0,30mm (30%) seguido de desinfecção com cloro (5mg Cl2/mL), mostrou-se eficiente na remoção dos parâmetros analisados para os quatro tratamentos estudados, compensando os valores menores de remoção observadas nas etapas anteriores. Todos os tratamentos estudados apresentaram resultados positivos para a formação de clorofórmio e bromodiclorometano, porém abaixo dos limites estabelecidos pela Portaria MS 518/04 para TTHM.
3

Dessalinização para produção de água potável : perspectivas para Portugal

Guerreiro, Mário Luís Ferreira Brandão January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Hidráulica). Faculdade de Engenharia. Universidade do Porto. 2009
4

Remoção de microcistinas por meio de oxidação química com hipoclorito de sódio e validação do método de análise por cromatografia líquida com detector de massas / Microcystins removal through oxidation with sodium hypochilorite and validation of liquid chromatography coupled with mass spectrometry as analytical method

Nascimento, Maria Martins do 06 December 2011 (has links)
Dissertação (mestrado)-Universidade de Brasília, Programa de Pós-Graduação em Tecnologia Ambiental e Recursos Hídricos, 2011. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2012-01-26T13:35:50Z No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / Approved for entry into archive by Elzi Bittencourt(elzi@bce.unb.br) on 2012-01-26T14:33:22Z (GMT) No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / Made available in DSpace on 2012-01-26T14:33:22Z (GMT). No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / As florações de cianobatérias provocadas pelo aporte de nutrientes nos corpos de água impactam a qualidade das águas. Esses micro-organismos ao serem lisados liberam toxinas para a água. O tratamento de água convencional - coagulação, floculação, sedimentação e filtração - não é eficiente na remoção dessas cianotoxinas dissolvidas, porém a oxidação no durante a etapa de desinfecção (cloração) pode ser uma alternativa para a remoção desses compostos. Sendo assim, o presente trabalho teve por objetivo estudar o processo de oxidação de microcistinas dissolvidas usando o hipoclorito de sódio como oxidante, avaliando a cinética de oxidação, influência da dose e tempo de contato, bem como a caracterização das microcistinas produzidas pela linhagem NPLJ-4 de Microcystis aeruginosa e a validação o método para determinação de microcistina-LR por cromatografia líquida com detector de massas (CL-MS/MS). Os resultados obtidos sugerem a presença de seis variantes de microcistinas produzidas pela linhagem NPLJ-4, sendo a mais abundante a [D-Leu] MCYST-LR. O método de determinação da MCYSTLR implementado apresentou, na faixa de 1-50 μg L-1, boa linearidade, com coeficiente de ajuste (r) maior que 0,99. A repetitividade do método, obtida mediante a fortificação de amostras com diferentes concentrações de microcistina-LR, apresentou resultados satisfatórios (CV % < 20). Os Limites de Detecção (LOD) e de Quantificação (LOQ) foram inferiores a 1,0 μg L-1 de MCYST-LR, valor máximo permito pela legislação brasileira sobre potabilidade da água, indicando a aplicabilidade do método para o controle de água para consumo humano. Nas condições avaliadas, microcistinas semi-purificadas oxidadas com hipoclorito de sódio em valor de pH 6, os resultados mostraram que a oxidação segue uma cinética de pseudo-primeira ordem em relação à concentração de microcistinas e a eficiência de remoção foi proporcional ao CT (concentração de cloro vezes tempo de contato). Para concentrações de microcistinas de cerca de 100, 40 e 20 μg L-1, os produtos CT mínimos necessários para obtenção de concentrações de microcistinas atendendo o padrão de potabilidade foram, respectivamente, 120, 60 e 30 mg L-1 min. ______________________________________________________________________________ ABSTRACT / Blooms of cyanobacteria caused by nutrients loads to water sources impacts water quality. When these microorganisms are lysed they release toxins into the water. The conventional water treatment, based in coagulation, flocculation, sedimentation and filtration, is not effective in removing these dissolved cyanotoxins, but the oxidation during chlorination can be an alternative for the removal of such microcontaminants. Therefore, this work aimed to study the oxidation of microcystins using sodium hypochlorite as oxidant, evaluating the oxidation kinetics, the influence of dose and oxidation time, as well as the characterization of microcystins variants produced by Microcystis aeruginosa NPLJ-4 strain and optimization and validation of the analytical method for determination of MCYST-LR by liquid chromatography coupled with mass spectrometry (LC-MS/MS). The results indicated the presence of six variants of microcystins produced by the M. aeruginosa NPLJ-4 strain, with the [D-Leu] MCYST-LR being the most abundant toxin. The LC-MS/MS method for quantification of MCYST-LR showed good linearity in the range of 1 to 50 μg L-1, with fitness coefficient (r) > 0.99. The repeatability, obtained by fortifying blank samples with different concentrations of microcystin-LR, was considered satisfactory (CV% < 20). The limits of detection (LOD) and quantification (LOQ) were lower than 1.0 mg L-1 of MCYST-LR, the Brazilian drinking water standard, suggesting the applicability of the method for the drinking water quality control. Under the conditions studied, oxidation of semi-purified microcystins with sodium hypochlorite at pH 6, the results showed that the oxidation followed a pseudo-first order kinetics regarding the microcystins concentration and the removal efficiency was related to CT product (concentration of chlorine times oxidation time). For concentrations of microcystins of around 100, 40 e 20 μg L-1, the minimum CT values of 120, 60 e 30 mg L-1 min, respectively, are necessary to guarantee residual concentrations of microcystins bellow de drinking water standard, 1.0 mg L-1.
5

Estudo da demanda de água não potável e desenvolvimento de um sistema de reuso de água cinza para habitações de interesse social.

SILVA, L. M. 22 February 2013 (has links)
Made available in DSpace on 2018-08-24T22:53:27Z (GMT). No. of bitstreams: 1 tese_6431_Dissertacao_Mestrado_LeaMarinaSilva.pdf: 9850603 bytes, checksum: 892b992c15f52044b8e338a5ffbae903 (MD5) Previous issue date: 2013-02-22 / Este trabalho estuda a demanda de água não potável e o desenvolvimento de um sistema de reúso de águas cinza para Habitações de Interesse Social (HIS). Para tanto, realiza a caracterização do perfil de consumo de água em uma comunidade formada por HIS o Residencial Jabaeté, em Vila Velha (ES); investiga quais ações de conservação de água melhor se aplicam no cotidiano da comunidade em questão, analisando o reúso frente às demais ações avaliadas; e, por fim, propõe algumas configurações possíveis de sistemas de reúso nessa comunidade por meio de projeto arquitetônico, no nível de estudo preliminar. Tais estudos apontaram um consumo médio de água nas HIS estudadas de 79 l/hab. dia e demais índices relativos à demanda de água potável em cada atividade doméstica (a mais representativa é a lavagem de roupas, responsável por aproximadamente 41% do consumo total). A metodologia utilizada foi aplicação de questionários e monitoramento do consumo de água pela leitura de hidrômetros. Através da aplicação de um método de suporte à decisão o Analytic Hierarchy Process (AHP), determinou-se a vantagem de práticas como uso de descarga dual e bacia segregadora de urina sobre a prática do reúso de água cinza. Além disso, foram realizados estudos projetuais de dois tipos de configurações de sistemas de reúso: o sistema descentralizado e o sistema semi-descentralizado, para os quais foram orçados os custos de implantação. Observou-se a vantagem econômica da adoção do sistema semi-descentralizado, cuja implantação pode ser até 112% mais barata que o sistema descentralizado.
6

Aplicação Combinada de Técnica de Otimização e Modelo de Qualidade de Água na Determinação de Eficiências de Sistemas de Tratamento de Efluentes Domésticos: uma Abordagem para Gerenciamento de Bacias Hidrográficas.

VALORY, J. P. L. 03 June 2013 (has links)
Made available in DSpace on 2018-08-24T22:53:29Z (GMT). No. of bitstreams: 1 tese_6735_Dissertação_versão_final.pdf: 1583392 bytes, checksum: b2f56f6be3d8580802ba0c47650969e4 (MD5) Previous issue date: 2013-06-03 / Este trabalho estuda a demanda de água não potável e o desenvolvimento de um sistema de reúso de águas cinza para Habitações de Interesse Social (HIS). Para tanto, realiza a caracterização do perfil de consumo de água em uma comunidade formada por HIS o Residencial Jabaeté, em Vila Velha (ES); investiga quais ações de conservação de água melhor se aplicam no cotidiano da comunidade em questão, analisando o reúso frente às demais ações avaliadas; e, por fim, propõe algumas configurações possíveis de sistemas de reúso nessa comunidade por meio de projeto arquitetônico, no nível de estudo preliminar. Tais estudos apontaram um consumo médio de água nas HIS estudadas de 79 l/hab. dia e demais índices relativos à demanda de água potável em cada atividade doméstica (a mais representativa é a lavagem de roupas, responsável por aproximadamente 41% do consumo total). A metodologia utilizada foi aplicação de questionários e monitoramento do consumo de água pela leitura de hidrômetros. Através da aplicação de um método de suporte à decisão o Analytic Hierarchy Process (AHP), determinou-se a vantagem de práticas como uso de descarga dual e bacia segregadora de urina sobre a prática do reúso de água cinza. Além disso, foram realizados estudos projetuais de dois tipos de configurações de sistemas de reúso: o sistema descentralizado e o sistema semi-descentralizado, para os quais foram orçados os custos de implantação. Observou-se a vantagem econômica da adoção do sistema semi-descentralizado, cuja implantação pode ser até 112% mais barata que o sistema descentralizado. Palavras chave: Consumo residencial de água; Água cinza; Conservação de água; Reúso; Habitação de interesse Social
7

Estimativa e aplicação dos coeficientes de dispersão longitudinal e de reaeração em corpos de água naturais /

Soares, Pétrick Anderson, Pinheiro, Adilson, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2011 (has links) (PDF)
Orientador: Adilson Pinheiro. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Ambiental.
8

Controlo de perdas aparentes em sistemas de abastecimento de água com utilização de telecontagem

Malheiro, Rui Miguel Gonçalves January 2011 (has links)
Tese de mestrado integrado. Engenharia Civil (Hidráulica). Universidade do Porto. Faculdade de Engenharia. 2011
9

Interferências do lançamento de efluente da ETE Salgado Filho na qualidade de água do córrego Anhanduí na cidade de Campo Grande (MS) /

Rodrigues, Danielle Antonia Malheiros. January 2006 (has links)
Orientador: Tsunao Matsumoto / Banca: Maurício Augusto Leite / Banca: Carlos Nobuyoshi Ide / Resumo: A água é não só um elemento primordial ao desenvolvimento humano, mas também um recurso essencial à vida. Hoje, é a sua qualidade que tem sido foco de preocupação de diversos pesquisadores, que vêm realizando estudos visando à determinação de parâmetros que influenciam a qualidade da água. O Índice de Qualidade da Água modificado pela CETESB (IQA-CETESB), transforma múltiplas informações técnicas em uma linguagem simples, através de uma classificação da área de estudo em uma escala que varia de muito ruim à excelente, de acordo com a National Sanitation Foundation (NSF), a qual selecionou nove parâmetros de maior importância na qualidade de água: DBO, oxigênio dissolvido, pH, temperatura, nitrogênio, fosfato total, sólidos totais, turbidez e coliformes fecais. No presente trabalho, o índice foi calculado para o córrego Anhanduí, no município de Campo Grande (MS), mais precisamente, a montante e a jusante da Estação de Tratamento de Esgoto Salgado Filho - ETE Salgado Filho. Este estudo foi realizado com a finalidade de se observar a qualidade do corpo receptor, o córrego Anhanduí, levando-se em conta, principalmente, as características da Região Urbana do Anhanduizinho. A qualidade da água presente no córrego foi acompanhada com doze parâmetros por ponto. O monitoramento teve a duração de oito meses, de março a outubro de 2006, a cada mês foram coletadas duas amostras, uma a montante e outra a jusante, do ponto de lançamento da ETE Salgado Filho entre os dias 27 e 30. De acordo com o IQA-CETESB a classificação média, do córrego Anhanduí foi considerada ruim a montante e péssima a jusante da ETE. Foi feita, ainda, uma análise comparativa dos resultados obtidos com a Resolução CONAMA 357/05, aonde foi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Water isnþt only a fundamental element to humam beings' development but it's also an essential source to life. Nowadays, the concermimg facused by several research workevs is the quality of the water. They have been carrying out some studies focusing the determination of the parameters which have an influence on the water quality. The water quality index modificated by CETESB (WQI-CETESB), transforms multiplied tecnical information into a simple language throuyh a classified areu of studies at a scale with variation from very bad to excellent, according to The National Sanitation Foundation (NSF), which it has selected the nine greatest important parameters in the water quality: BOD, Dissolved Oxygen, pH, Temperature, Nitrogen, Total Phosphate, Toatals Solid, Turbidity and phecal coliforms. At this presented study, the calculated index was for the Anhanduí Stream in Campo Grande County (MS), more precisely upstrean and downstrean the Salgado Filho Sewage Treatment Works - STW Salgado Filho. The aim of this study was to obsrve the quality of the receptor body, Anhanduí Stream taking into account mainly the characteristics of the urban region of Anhanduizinho. The present stream water quality was followed with twelve parameters pev point. The following up last eight months, from yarch thru October 2006, at each month two samples were collected, one upstrean and one downstrean the STW Salgado Filho among the 27th and the 30th days. According to WQI - CETESB the average classification of the Anhanduí stream was as bad upstrean and as very bad downstrean the STW. A comparative analyse was also made, arised from the obtained results with the Conama 357/05 Resolution, where it was observed that the critcest... (Complete abstract, click electronic access below) / Mestre
10

Dinâmica da qualidade da água em tanques de peixes de sistema pesque-pague : aspectos físico-químicos e plâncton /

Millan, Rodrigo Ney. January 2009 (has links)
Orientadora: Lúcia Helena Sipaúba Tavares / Banca: Márcia Noélia Eler / Banca: Luiz Augusto do Amaral / Resumo: Estabelecimentos conhecidos como pesque-pagues tornaram-se comuns, impulsionando a economia de pequenos proprietários rurais, sendo opção de lazer, bem como auxiliando, no escoamento de parte da produção pesqueira de água doce. Em virtude disso, estudos são importantes para conhecimento dos padrões de qualidade de água, uma vez que estes determinam o sucesso do empreendimento. O estudo foi conduzido no pesque-pague do orfanato "Lar do Caminho", na cidade de Jaboticabal/SP. O sistema apresenta fluxo contínuo de água, onde foram amostrados mensalmente sete pontos de coleta ao longo de um ano (jul/2005 a ago/2006), sendo dois na água de abastecimento (P1 = nascente e P2 = área alagável), três nos tanques (P3 = tanque 1, P4 = tanque 2 e P5 = tanque 3) e dois na água de saída do sistema (P6 = início do efluente, Pfe = final do efluente). Foram analisadas variáveis físicas e químicas da água como temperatura, pH, oxigênio dissolvido, dureza total, alcalinidade total, amônia, nitrato, nitrito, fósforo total, ortofosfato, clorofila-a, DBO5, além da composição da comunidade planctônica. Na região do estudo dois períodos climáticos são bem definidos, a estação seca (ago/2005 a nov/2005 e abr/2006 a jul/2006) e a chuvosa (dez/2005 a mar/2006). Observou-se que estas duas estações, assim como o manejo aplicado ao sistema, interferiram diretamente na dinâmica da qualidade da água, tanto no aspecto físicoquímico como na comunidade planctônica. O sistema pesque-pague, com fluxo contínuo de abastecimento de água, acumulou nutrientes ao longo dos pontos, principalmente no último tanque. Porém, o canal efluente contendo macrófitas e rochas, com aproximadamente 400m de extensão, propiciou melhoria na qualidade da água que é lançada no ambiente. / Abstract: Sports Fishing have become extremely common in Brazil and have provided a financial sources to small farmstead owners. They are not only places for leisure but are an option to commercialize part of the freshwater fish produce. Analysis on the subject is important since water quality is a high asset within the entrepreneurship success. Analysis was undertaken in the 'Lar do Caminho Orphanage' Sport Fishing complex in Jaboticabal SP Brazil. The system has a continuous flow of water in which seven collection sites were sampled, once a month, between July 2005 and August 2006. Two sites lay in the supply water (P1 = source and P2 = wetland), three in tanks (P3 = tank 1; P4 = tank 2; P5 = tank 3) and two in the system's exit water (P6 = initial point of effluent, Pfe = end of effluent). The water's physical and chemical variables, such as temperature, pH, dissolved oxygen, total hardness, total alkalinity, ammonia, nitrate, nitrite, total phosphorus, orthophosphorus, chlorophyll-a, DBO5 and the composition of plankton community were analyzed. Two well-defined climate periods, dry (August 2005 to November 2005 and April 2006 to July 2006) and rainy seasons (December 2005 to March 2006) are featured in the region. The two seasons and management of the system affect directly the dynamics of water quality in the physical and chemical aspects and the plankton community. Continuous water supply sports fishing accumulated nutrients in all sites, especially in the last tank. However, the 400-m long effluent channel with macrophytes and rocks improved the water quality unloaded within the environment. / Mestre

Page generated in 0.1237 seconds