• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ανάπτυξη block ανιχνευτών για τομογράφο εκπομπής ποζιτρονίων (PET)

Νικολάου, Μαρία Ελένη 10 October 2008 (has links)
Η Τομογραφία Εκπομπής Ποζιτρονίων, η οποία συχνά αναφέρεται με βάση το ακρωνύμιό της, PET (Positron Emission Tomography), αποτελεί μία πρωτοποριακή τεχνική απεικόνισης η οποία παρέχει εγκάρσιες τομές της λειτουργίας των διαφόρων δομών του ανθρωπίνου σώματος. Η Τομογραφία PET επιτρέπει την μεταβολική απεικόνιση αυτών των δομών (σε αντίθεση με τις ακτίνες-Χ και την Υπολογιστική Τομογραφία (CT – Computer Tomography) οι οποίες παρέχουν ανατομική απεικόνιση), σε μοριακό επίπεδο, και αυτός είναι ο λόγος που συχνά η Τομογραφία PET αναφέρεται ως μοριακή απεικόνιση. Ειδικότερα, οι τομογράφοι PET για μικρά ζώα (Small Animal PET) οι οποίοι απαιτούν ιδιαίτερα υψηλή διακριτική ικανότητα, διαδραματίζουν σημαντικό ρόλο στην βιολογία και στις in-vivo μελέτες της φαρμακοκινητικής των ιχνηθετών και του μεταβολισμού. Σύμφωνα με τη βιβλιογραφία έχουν αναφερθεί διάφοροι τύποι τομογράφων PET, στους οποίους χρησιμοποιήθηκαν διάφοροι τύποι ανιχνευτικών διατάξεων, με διαφορετικό σχεδιασμό σε κάθε περίπτωση. Η τεχνολογία αυτών των τομογράφων βασίζεται στη χρήση μικρών ανόργανων κρυστάλλων, κυρίς αποτελούμενων από BGO, GSO και LSO, οι οποίοι σχηματίζουν ένα block στο οποίο έχει προσαρτηθεί ένας φωτοπολλαπλασιαστής είτε με ευαισθησία θέσης (PS – PMT: Position Sensitive PhotoMultiplier Tube), είτε με πολλαπλές ανόδους (multianode PMT). To BGO (Bismuth Germanate Oxide) είναι το υλικό που χρησιμοποιείται σε αρκετούς εμπορικούς Τομογράφους, έχοντας πλέον αντικαταστήσει το ιωδιούχο νάτριο (ΝαΙ). Ένα πρότυπο σύστημα small animal PET χαμηλού κόστους βρίσκεται υπό ανάπτυξη, προκειμένου να μελετήσουμε τα επιμέρους σχεδιαστικά χαρακτηριστικά του και να μετρήσουμε την απόδοσή του. Ο βασικός block ανιχνευτής αποτελείται από μία 16×16 διάταξη επιμέρους BGO κρυστάλλων διαστάσεων 3.75×3.75×20 mm3, ο οποίος έχει τοποθετηθεί με ειδική διεργασία στην επιφάνεια ενός Hamamatsu R-2486 PSPMT. Με τη χρήση κατάλληλων ηλεκτρονικών διατάξεων και την ανάπτυξη ειδικού λογισμικού πραγματοποιήθηκαν μετρήσεις της απόδοσης των επιμέρους ανιχνευτών καθώς επίσης και μετρήσεις σχετικές με τους φωτοπολλαπλασιαστές. / Positron Emission Tomography, often referred to by its acronym, PET, is an emerging radiologic modality that yields transverse tomographic images of functioning organs in the human body. PET enables the metabolic imaging of organs (as opposed to the anatomic imaging provided by techniques such as the X-ray imaging or the Computerized Tomography (CT)), in molecular level, and this is the reason why it is characterized as molecular imaging. Especially, small animal PET tomographs which require high spatial resolution can play an important role in biology and studies of in vivo tracer pharmacokinetics and metabolism. Various implementations have been reported in the literature using a variety of detector and design technologies. The basic technology for these scanners is based on small inorganic crystals, mainly from BGO, GSO, and LSO, forming detector blocks read out by position sensitive and multianode PMTs. BGO is the material used in a lot of commercial scanners, having replaced NaI, mainly because BGO has higher stopping power and it is not hygroscopic. We have been developing a low-cost small animal PET prototype, in order to study specific design characteristics and measure its performance. The basic block detector design consists of a 16×16 array of 3.75×3.75×20 mm3 individual BGO crystals coupled to a Hamamatsu R-2486 PSPMT. Measurements of the individual detector performance as well as measurements of the PSPMTs have been performed.
2

Experimental evaluation of single-crystal and granular scintillators in medical imaging detectors : application in an experimental prototype imaging system / Πειραματική αξιολόγηση μονοκρυσταλλικών και κοκκώδους μορφής σπινθηριστών σε ανιχνευτές ιατρικής απεικόνισης : εφαρμογή σε πειραματικό πρωτότυπο απεικονιστικό σύστημα

Δαυίδ, Ευστράτιος 20 October 2010 (has links)
The aim of the present thesis is to evaluate fast scintillator materials, in both single-crystal and powder form, for possible usage in dedicated gamma ray imaging applications as well as in X-ray imaging techniques, requiring high frame rates. Powder scintillators are traditionally used in conventional X-ray imaging due to their property to produce high resolution images. This is because laterally directed optical photons, originating from the point of X-ray interaction, are strongly attenuated by light scattering effects on powder grains. This property however is their principal drawback for routine Nuclear Medicine applications. In these applications, photon counting accuracy rather than spatial resolution is required and to this aim high transparency crystals are used. In the present study we have tried to estimate whether the use of powder phosphors can improve the image quality in a dedicated gamma-ray system where spatial resolution than sensitivity is of primary significance. Evaluation was performed in thin and thick phosphor layers easily produced in the laboratory. In addition we present a low cost solution – consisting of a thick continuous powder scintillator screen – for use in dedicated high resolution small gamma imager. The advantages and disadvantages of proposed powder detector performance were compared to two standard 3 x 3 x 5mm3 and 2 x 2 x 3mm3 pixellated CsI:Tl scintillator detector configurations. System performance in terms of system sensitivity, system spatial resolution, energy resolution and linear energy response were measured at energy of 140 keV for close-proximity nuclear emission imaging. All measurements were carried out in photon counting mode in planar imaging configuration. The investigation was divided into two parts: Fast powder scintillators: In this part, powder scintillator screens of LSO:Ce, YAG:Ce and GOS:Pr were prepared in various coating thicknesses. Measurements concerning determination of emission spectra and absolute luminescence efficiency were carried out under X-ray excitation from 22 to 140 kV. Related parameters giving informations on luminescence and intrinsic properties of the phosphors such as X-ray luminescence efficiency, quantum detection efficiency, energy absorption efficiency and intrinsic conversion efficiency were also examined. Low cost and high resolution detector module: The goal of this part was to propose and evaluate a low cost solution for detector module – consisting of a thick continuous powder scintillator screen – for use in dedicated high resolution small gamma imagers. For the latter purpose, we examined the performance of the aforementioned fast powder scintillators in the form of thick screens easily produced in the laboratory. System performance in terms of system sensitivity, system spatial resolution, energy resolution and linear energy response were measured and compared for two standard 3 x 3 x 5mm3 and 2 x 2 x 3mm3 pixellated CsI:Tl. / Ο σκοπός της παρούσας διατριβής είναι η αποτίμηση φθοριζόντων υλικών υψηλής απόκρισης, τόσο σε κρυσταλλική όσο και σε κοκκώδη μορφή για πιθανή χρησιμοποίησή τους σε συγκεκριμένους τύπους ανιχνευτικών συστημάτων Πυρηνικής Ιατρικής όπως επίσης σε συστήματα απεικόνισης με ακτίνες Χ που απαιτούν πολύ γρήγορες λήψεις ιατρικής εικόνας. Τα φθορίζοντα υλικά κοκκώδους μορφής χρησιμοποιούνται ευρύτατα στην απεικόνιση με ακτίνες-Χ λόγω της υψηλής διακριτικής ικανότητας που μπορεί να επιτευχθεί. Στην παρούσα διατριβή μελετήθηκε κατά πόσο η χρήση νέων, γρήγορων φθοριζόντων υλικών κοκκώδους μορφής μπορεί να βελτιώσει την απόδοση συγκεκριμένων τύπων ανιχνευτικών συστημάτων Πυρηνικής Ιατρικής (π.χ. dedicated small nuclear imagers), στα οποία η διακριτική ικανότητα του συστήματος είναι πιο σημαντική από την ευαισθησία. Η αποτίμηση έγινε σε φθορίζοντα μεγάλου πάχους που παρασκευάστηκαν στο εργαστήριο. Επιπρόσθετα στην παρούσα διατριβή παρουσιάζεται η εφαρμογή ενός χαμηλού κόστους συμπαγούς ανιχνευτικού υλικού κοκκώδους μορφής σε ένα εξειδικευμένο σύστημα Πυρηνικής Ιατρικής. Γίνεται συστηματική μελέτη και εκτενής αναφορά στα πλεονεκτήματα και τα μειονεκτήματα αυτού του συστήματος. Τα αποτελέσματα συγκρίνονται με αντίστοιχα αποτελέσματα που ελήφθησαν με χρήση διακριτοποιημένων σπινθηριστών τύπου CsI:Tl, μεγέθους 3 x 3 x 5mm3 και 2 x 2 x 3 mm3. Η απόδοση του συστήματος ως προς την ευαισθησία (sensitivity), τη χωρική διακριτική ικανότητα (spatial resolution) και την ενεργειακή διακριτική ικανότητα (energy resolution) αποτιμήθηκε για ενέργεια 140 keV, που αντιστοιχεί στην ενέργεια του ισοτόπου 99mTc που χρησιμοποιείται ευρύτατα σε εξετάσεις Πυρηνικής Ιατρικής. Η πειραματική μελέτη χωρίστηκε σε δύο μέρη: Φθορίζοντα υλικά κοκκώδους μορφής: Στο πρώτο μέρος της παρούσας διδακτορικής διατριβής μελετήθηκαν τα φθορίζοντα υλικά κοκκώδους μορφής LSO:Ce, YAG:Ce και GOS:Pr σε διάφορα πάχη και για μεγάλη κλίμακα ενεργειών (Υψηλή τάση λυχνίας ακτίνων-Χ από 22 kV έως 140 kV). Ανιχνευτής χαμηλού κόστους και υψηλής διακριτικής ικανότητας: Ο τελικός στόχος της παρούσας διατριβής ήταν η κατασκευή ενός ενιαίου ανιχνευτή, βασισμένου σε σπινθηριστή κοκκώδους μορφής, χαμηλού κόστους και υψηλής διακριτικής ικανότητας, κατάλληλου για χρήση σε εξειδικευμένα συστήματα Πυρηνικής Ιατρικής. Για το σκοπό αυτό μελετήθηκε η συμπεριφορά των υλικών κοκκώδους μορφής LSO:Ce, YAG:Ce και GOS:Pr υπό διέγερση ακτίνων γάμμα με ισότοπο Τεχνητίου (99mTc), ενέργειας 140 keV, που χρησιμοποιείται ευρύτατα στην Πυρηνική Ιατρική. Τα υλικά αυτά υπό την μορφή ενιαίου, μεγάλου πάχους ( ≥2mm) και διαμέτρου (9 cm), συμπαγούς ανιχνευτή αξιολογήθηκαν με τεχνικές απεικόνισης μονού φωτονίου (single photon counting mode).

Page generated in 0.0198 seconds