Spelling suggestions: "subject:"acid erosion"" "subject:"cid erosion""
1 |
Studies on dental erosion and attrition using a new ultrasonication and profilometry techniqueEisenburger, Michael Gregor Walter January 2002 (has links)
No description available.
|
2 |
Avaliação in vitro da microdureza superficial do esmalte bovino exposto a soluções ácidas, após receber ou não, clareamento com peróxido de hidrogênio a 35%Zanet, Caio Gorgulho [UNESP] 09 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-04-09Bitstream added on 2014-06-13T20:22:07Z : No. of bitstreams: 1
zanet_cg_dr_sjc.pdf: 1385810 bytes, checksum: 116232ec5fb14d4d25cddd152219e177 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Erosão é a perda superficial do esmalte dentário causada por processos químicos que não envolvem bactérias. Alguns fatores intrínsecos e extrínsecos como a presença de substâncias ácidas na cavidade bucal, promovem uma redução do pH do meio, aumentando a erosão ácida. Assim, o objetivo deste estudo foi avaliar a microdureza do esmalte de dentes bovinos clareados e não clareados com peróxido de hidrogênio a 35 %, após a ação de: refrigerante a base de cola, suco artificial em pó contendo citrato de sódio e ácido clorídrico. Os corpos de prova foram divididos em dois grupos, onde 45 amostras de um dos grupos receberam a ação do agente clareador uma vez por semana durante duas semanas. Após este período, as amostras de cada grupo inicial foi dividido em 3 grupos com 15 amostras cada, as quais foram imersas nas soluções ácidas diariamente por 5 minutos e permanecendo 23 horas e 55 minutos em saliva artificial. O experimento foi realizado por 21 dias e as leituras de microdureza de cada corpo de prova foi realizada semanalmente. Os dados obtidos segundo as variáveis: tempo, substância ácida e condição do substrato (esmalte clareado ou não) foram submetidos aos testes estatísticos: Anova e Tukey. Concluiuse que todas as soluções ácidas testadas interferiram com a microdureza do esmalte. Dentes clareados foram os mais susceptíveis aos efeitos erosivos das soluções ácidas. O ácido clorídrico causou o maior dano ao esmalte dentário e o tempo de exposição do esmalte às soluções ácidas influiu diretamente na quantidade de desmineralização. / Acid erosion is the loss of enamel surface caused by chemical processes that do not involve bacteria. Some intrinsic and extrinsic factors, as the presence of acid substances in the oral cavity, promote a pH reduction, increasing acid erosion. Thus, the aim of this study was to evaluate the microhardness of bleaching and not bleaching bovine enamel after the effect of a cola drink, an artificial powder juice and hydrochloric acid. The data obtained by the variables: time, acid solution and condition of substrate (enamel whitening or not whitening) were subjected to statistical tests: ANOVA and Tukey. It was concluded that all acid solutions tested interfered with the enamel microhardness. Hydrochloric acid caused the biggest damage to enamel and the time of enamel exposure to acid solutions directly influenced the demineralization amount. Whitened enamel was more affected by acid erosion. -
|
3 |
Fabricação de microeletrodos para aplicações em microscopia eletroquímica de varredura / Fabrication of microelectrodes for applications in scanning electrochemical microscopyCastro, Pollyana Souza 19 August 2011 (has links)
No presente trabalho, microeletrodos de platina foram fabricados e empregados juntamente com a técnica de Microscopia Eletroquímica de Varredura (Scanning Electrochemical Microscopy - SECM) para a obtenção de informações a respeito da erosão ácida do esmalte dentário. Em uma etapa inicial do projeto, um procedimento de fabricação de microeletrodos utilizando o equipamento Micropipette Puller foi desenvolvido. A selagem e o polimento da área ativa dos dispositivos foram consideradas etapas críticas do processo de construção. Uma bomba a vácuo foi empregada durante a fabricação dos dispositivos, o que aumentou a eficiência da selagem do vidro sobre a microfibra. Os parâmetros do equipamento necessários à fabricação dos dispositivos foram otimizados e desta forma obteve-se uma metodologia reprodutível e eficiente. Assim, microeletrodos de diversos materiais e dimensões foram construídos e avaliados quanto à utilização em SECM. Uma metodologia alternativa para a redução no tamanho da ponta de prova foi proposta. Um polimento cuidadoso na ponta de prova foi feito e através de comparações entre Curvas de Aproximação teóricas e experimentais, chegou-se a microeletrodos com RG (razão raio do vidro e raio do microeletrodo) próximos de 15. Em uma segunda etapa do projeto, a erosão ácida do esmalte dentário foi investigada utilizando SECM. Empregando um microeletrodo de platina, foram obtidas imagens SECM que revelaram haver um intenso consumo de íons hidrogênio na interface esmalte dentário-solução ácida. Isso ocorre devido à reação de desmineralização da camada protetora do dente, sendo comprovado que este processo é relativamente rápido. Imagens SECM também mostraram diferenças topográficas do esmalte dentário e, desta forma, após um intenso processo de desmineralização ácida, a SECM foi utilizada para estimar a espessura da camada de esmalte erodida. Com o auxílio das Curvas de Aproximação concluiu-se que, após 48 horas de exposição, a camada de esmalte erodida foi de 18 µm e após 96 horas a espessura da camada erodida aumentou para 25 µm. Microscopia de Força Atômica também foi utilizada para visualização das mudanças morfológicas após o esmalte permanecer em contato com diferentes bebidas de elevada acidez. Desta forma, pode-se concluir que em longo prazo o esmalte dentário pode ser removido devido ao contato com substâncias ácidas, expondo a dentina ao ambiente bucal e gerando problemas de hipersensibilidade dentária. / In this study, platinum microelectrodes were fabricated with a Micropipette Puller and used in Scanning Electrochemical Microscopy (SECM) to obtain information on the acid erosion of tooth enamel. The sealing and polishing of the active area of the fabricated devices are considered critical steps in the construction process, hence a vacuum pump was used to enhance the efficiency of the seal of the glass microfiber. The parameters of the equipment were optimized allowing a reproducible and efficient method to be developed. Thus, microelectrodes of various materials and dimensions were constructed and evaluated for use in SECM. An alternative method for reducing the size of the probe was also proposed. A careful polishing of the probe was done and by comparing theoretical and experimental approach curves, microelectrodes with RG values near to 15 were obtained. The acid erosion of dental enamel was investigated using SECM and a platinum microelectrode as a probe to H+ ions. The obtained images revealed a significant and relatively fast consumption of H+ ions at the interface enamel-acid solution, as a consequence of the demineralization reaction of the protective layer. SECM images also showed topographical differences with respect to the tooth enamel and after an exhaustive process of acid demineralization, the thickness of the layer of eroded enamel was estimated. By using approach curves it was concluded that the thickness of the eroded enamel layer was around 18 µm after 48 hours of exposure, this value being enhanced to 25 µm after 96 hours. Atomic Force Microscopy was also used to confirm the morphological changes after exposing the enamel to different beverages with high acidity. Accordingly, one can conclude that the acid erosion of enamel exposes the dentin to the oral environment and creates problems associated with dental hypersensitivity.
|
4 |
Fabricação de microeletrodos para aplicações em microscopia eletroquímica de varredura / Fabrication of microelectrodes for applications in scanning electrochemical microscopyPollyana Souza Castro 19 August 2011 (has links)
No presente trabalho, microeletrodos de platina foram fabricados e empregados juntamente com a técnica de Microscopia Eletroquímica de Varredura (Scanning Electrochemical Microscopy - SECM) para a obtenção de informações a respeito da erosão ácida do esmalte dentário. Em uma etapa inicial do projeto, um procedimento de fabricação de microeletrodos utilizando o equipamento Micropipette Puller foi desenvolvido. A selagem e o polimento da área ativa dos dispositivos foram consideradas etapas críticas do processo de construção. Uma bomba a vácuo foi empregada durante a fabricação dos dispositivos, o que aumentou a eficiência da selagem do vidro sobre a microfibra. Os parâmetros do equipamento necessários à fabricação dos dispositivos foram otimizados e desta forma obteve-se uma metodologia reprodutível e eficiente. Assim, microeletrodos de diversos materiais e dimensões foram construídos e avaliados quanto à utilização em SECM. Uma metodologia alternativa para a redução no tamanho da ponta de prova foi proposta. Um polimento cuidadoso na ponta de prova foi feito e através de comparações entre Curvas de Aproximação teóricas e experimentais, chegou-se a microeletrodos com RG (razão raio do vidro e raio do microeletrodo) próximos de 15. Em uma segunda etapa do projeto, a erosão ácida do esmalte dentário foi investigada utilizando SECM. Empregando um microeletrodo de platina, foram obtidas imagens SECM que revelaram haver um intenso consumo de íons hidrogênio na interface esmalte dentário-solução ácida. Isso ocorre devido à reação de desmineralização da camada protetora do dente, sendo comprovado que este processo é relativamente rápido. Imagens SECM também mostraram diferenças topográficas do esmalte dentário e, desta forma, após um intenso processo de desmineralização ácida, a SECM foi utilizada para estimar a espessura da camada de esmalte erodida. Com o auxílio das Curvas de Aproximação concluiu-se que, após 48 horas de exposição, a camada de esmalte erodida foi de 18 µm e após 96 horas a espessura da camada erodida aumentou para 25 µm. Microscopia de Força Atômica também foi utilizada para visualização das mudanças morfológicas após o esmalte permanecer em contato com diferentes bebidas de elevada acidez. Desta forma, pode-se concluir que em longo prazo o esmalte dentário pode ser removido devido ao contato com substâncias ácidas, expondo a dentina ao ambiente bucal e gerando problemas de hipersensibilidade dentária. / In this study, platinum microelectrodes were fabricated with a Micropipette Puller and used in Scanning Electrochemical Microscopy (SECM) to obtain information on the acid erosion of tooth enamel. The sealing and polishing of the active area of the fabricated devices are considered critical steps in the construction process, hence a vacuum pump was used to enhance the efficiency of the seal of the glass microfiber. The parameters of the equipment were optimized allowing a reproducible and efficient method to be developed. Thus, microelectrodes of various materials and dimensions were constructed and evaluated for use in SECM. An alternative method for reducing the size of the probe was also proposed. A careful polishing of the probe was done and by comparing theoretical and experimental approach curves, microelectrodes with RG values near to 15 were obtained. The acid erosion of dental enamel was investigated using SECM and a platinum microelectrode as a probe to H+ ions. The obtained images revealed a significant and relatively fast consumption of H+ ions at the interface enamel-acid solution, as a consequence of the demineralization reaction of the protective layer. SECM images also showed topographical differences with respect to the tooth enamel and after an exhaustive process of acid demineralization, the thickness of the layer of eroded enamel was estimated. By using approach curves it was concluded that the thickness of the eroded enamel layer was around 18 µm after 48 hours of exposure, this value being enhanced to 25 µm after 96 hours. Atomic Force Microscopy was also used to confirm the morphological changes after exposing the enamel to different beverages with high acidity. Accordingly, one can conclude that the acid erosion of enamel exposes the dentin to the oral environment and creates problems associated with dental hypersensitivity.
|
5 |
Avaliação in vitro da microdureza superficial do esmalte bovino exposto a soluções ácidas, após receber ou não, clareamento com peróxido de hidrogênio a 35% /Zanet, Caio Gorgulho. January 2008 (has links)
Orientador: Marcelo Fava de Moraes / Banca: Rebeca Di Nicoló / Banca: Sigmar de Melo Rode / Banca: Bruno das Neves Chagas Cavalcanti / Banca: Mônica Andrade Lotufo / Resumo: Erosão é a perda superficial do esmalte dentário causada por processos químicos que não envolvem bactérias. Alguns fatores intrínsecos e extrínsecos como a presença de substâncias ácidas na cavidade bucal, promovem uma redução do pH do meio, aumentando a erosão ácida. Assim, o objetivo deste estudo foi avaliar a microdureza do esmalte de dentes bovinos clareados e não clareados com peróxido de hidrogênio a 35 %, após a ação de: refrigerante a base de cola, suco artificial em pó contendo citrato de sódio e ácido clorídrico. Os corpos de prova foram divididos em dois grupos, onde 45 amostras de um dos grupos receberam a ação do agente clareador uma vez por semana durante duas semanas. Após este período, as amostras de cada grupo inicial foi dividido em 3 grupos com 15 amostras cada, as quais foram imersas nas soluções ácidas diariamente por 5 minutos e permanecendo 23 horas e 55 minutos em saliva artificial. O experimento foi realizado por 21 dias e as leituras de microdureza de cada corpo de prova foi realizada semanalmente. Os dados obtidos segundo as variáveis: tempo, substância ácida e condição do substrato (esmalte clareado ou não) foram submetidos aos testes estatísticos: Anova e Tukey. Concluiuse que todas as soluções ácidas testadas interferiram com a microdureza do esmalte. Dentes clareados foram os mais susceptíveis aos efeitos erosivos das soluções ácidas. O ácido clorídrico causou o maior dano ao esmalte dentário e o tempo de exposição do esmalte às soluções ácidas influiu diretamente na quantidade de desmineralização / Abstract: Acid erosion is the loss of enamel surface caused by chemical processes that do not involve bacteria. Some intrinsic and extrinsic factors, as the presence of acid substances in the oral cavity, promote a pH reduction, increasing acid erosion. Thus, the aim of this study was to evaluate the microhardness of bleaching and not bleaching bovine enamel after the effect of a cola drink, an artificial powder juice and hydrochloric acid. The data obtained by the variables: time, acid solution and condition of substrate (enamel whitening or not whitening) were subjected to statistical tests: ANOVA and Tukey. It was concluded that all acid solutions tested interfered with the enamel microhardness. Hydrochloric acid caused the biggest damage to enamel and the time of enamel exposure to acid solutions directly influenced the demineralization amount. Whitened enamel was more affected by acid erosion / Doutor
|
6 |
Resistência de união de restaurações diretas em resina composta em dentina humana previamente submetida à erosão ácida / Microtensile bond strength of composite resin direct restorations on dentin previously submitted to acid erosionRigolizzo, Daniela dos Santos 11 September 2013 (has links)
A lesão não cariosa causada pela dissolução da estrutura dentária sem o envolvimento bacteriano é denominada lesão de erosão dental. Existe ainda a falta de consenso quanto ao tratamento dessas lesões, além de pouco conhecimento quanto ao comportamento delas frente aos procedimentos adesivos. Dentre os mais realizados, tratamentos através de restaurações adesivas têm sido os de melhor resultado. Este trabalho teve como objetivo avaliar a resistência de união (TBS) de restaurações de resina composta realizadas sobre um substrato de dentina erodida simulada, utilizando dois sistemas adesivos diferentes. 40 terceiros molares humanos não irrompidos tiveram o esmalte do terço oclusal completamente removidos, deixando a dentina exposta. Após ter sua superfície dentinária regularizada com lixa de carbeto de silício granulação #600, cada dente foi dividido ao meio, criando assim, 40 amostras pareadas, sendo uma das metades a amostra controle e a outra, experimental. Esta passou por um protocolo de criação de lesão de erosão simulada. Sobre o substrato dentinário de todas as amostras, foram confeccionadas restaurações em resina composta Z350 (3M ESPE). Previamente às restaurações, 20 amostras controle e suas respectivas experimentais foram condicionadas utilizando ácido forfórico 37% e sistema adesivo Adper Single Bond 2 (3M ESPE) (amostras CSB e ESB). As outras 20 amostras receberam o sistema adesivo auto-condicionante Clearfill SE (Kuraray) (amostras CCFe ECF). As amostras produziram palitos de aproximadamente 1,0 mm2 que foram submetidos ao teste de microtração com velocidade média de 0,5 mm/min até a fratura. Resultados estatísticos mostraram haver diferença significativa entre os grupos (usando ANOVA 1 variância, F=4,643). As amostras experimentais tratadas previamente com o adesivo Clearfill SE (ECF) mostraram valores de resistência de união significativamente maios altos quando comparadas com os valores dos outros grupos (m=42.16 ±20.509 Mpa) (p=0,0082). / Non carious lesions caused by dentals structure dissolution without involving bacterial acids are called dental erosion. There is still limited information regarding which treatments should be considered, as well as to how the eroded dentin behaves in adhesive procedures. This study aims to evaluate the effect of different adhesive systems on micro-tensile bond strength (TBS) on eroded dentin and its paired sound substrate sample. 40 non irrupted third human molars had the oclusal enamel removed with a low-speed diamond saw and their exposed superficial dentin surfaces were submitted to polishing with wet # 600-grit silicon carbide sandpaper to remove remaining enamel and plane the surface. Each molar was divided into two equal halves originating 40 paired samples- one control and one experimental. All experimental samples underwent a pH cycling protocol to create a simulated dental erosion lesion. A composite resin Z350 (3M ESPE) restoration was built on each samples surface. Previous to restoration, control group and their respective experimental halves were divided into 2 sub-groups. 20 control + experimental samples were treated with 37% phosphoric acid and Adper Single Bond 2 (3M ESPE) (CSB and ESB); The other 20 control+ experimental samples were treated with Clearfill SE (Kuraray) (CSE and ESE). All 40 restored teeth were cut yielding stick-shapped samples with a cross-sectional area of approximately 1.0 mm2 and were submitted to a micro-tensile force running at a crosshead speed of 0.5 mm/min until fracture. Statistic results showed significant difference among the groups (using the ANOVA test F= 4,643). The eroded dentin samples submitted to surface treatment with Clearfill SE (ECF) prior to restoration showed significantly higher bond strength results when compared to all the other groups (m=42.16 ±20.509 Mpa) (p=0,0082).
|
7 |
Resistência de união de restaurações diretas em resina composta em dentina humana previamente submetida à erosão ácida / Microtensile bond strength of composite resin direct restorations on dentin previously submitted to acid erosionDaniela dos Santos Rigolizzo 11 September 2013 (has links)
A lesão não cariosa causada pela dissolução da estrutura dentária sem o envolvimento bacteriano é denominada lesão de erosão dental. Existe ainda a falta de consenso quanto ao tratamento dessas lesões, além de pouco conhecimento quanto ao comportamento delas frente aos procedimentos adesivos. Dentre os mais realizados, tratamentos através de restaurações adesivas têm sido os de melhor resultado. Este trabalho teve como objetivo avaliar a resistência de união (TBS) de restaurações de resina composta realizadas sobre um substrato de dentina erodida simulada, utilizando dois sistemas adesivos diferentes. 40 terceiros molares humanos não irrompidos tiveram o esmalte do terço oclusal completamente removidos, deixando a dentina exposta. Após ter sua superfície dentinária regularizada com lixa de carbeto de silício granulação #600, cada dente foi dividido ao meio, criando assim, 40 amostras pareadas, sendo uma das metades a amostra controle e a outra, experimental. Esta passou por um protocolo de criação de lesão de erosão simulada. Sobre o substrato dentinário de todas as amostras, foram confeccionadas restaurações em resina composta Z350 (3M ESPE). Previamente às restaurações, 20 amostras controle e suas respectivas experimentais foram condicionadas utilizando ácido forfórico 37% e sistema adesivo Adper Single Bond 2 (3M ESPE) (amostras CSB e ESB). As outras 20 amostras receberam o sistema adesivo auto-condicionante Clearfill SE (Kuraray) (amostras CCFe ECF). As amostras produziram palitos de aproximadamente 1,0 mm2 que foram submetidos ao teste de microtração com velocidade média de 0,5 mm/min até a fratura. Resultados estatísticos mostraram haver diferença significativa entre os grupos (usando ANOVA 1 variância, F=4,643). As amostras experimentais tratadas previamente com o adesivo Clearfill SE (ECF) mostraram valores de resistência de união significativamente maios altos quando comparadas com os valores dos outros grupos (m=42.16 ±20.509 Mpa) (p=0,0082). / Non carious lesions caused by dentals structure dissolution without involving bacterial acids are called dental erosion. There is still limited information regarding which treatments should be considered, as well as to how the eroded dentin behaves in adhesive procedures. This study aims to evaluate the effect of different adhesive systems on micro-tensile bond strength (TBS) on eroded dentin and its paired sound substrate sample. 40 non irrupted third human molars had the oclusal enamel removed with a low-speed diamond saw and their exposed superficial dentin surfaces were submitted to polishing with wet # 600-grit silicon carbide sandpaper to remove remaining enamel and plane the surface. Each molar was divided into two equal halves originating 40 paired samples- one control and one experimental. All experimental samples underwent a pH cycling protocol to create a simulated dental erosion lesion. A composite resin Z350 (3M ESPE) restoration was built on each samples surface. Previous to restoration, control group and their respective experimental halves were divided into 2 sub-groups. 20 control + experimental samples were treated with 37% phosphoric acid and Adper Single Bond 2 (3M ESPE) (CSB and ESB); The other 20 control+ experimental samples were treated with Clearfill SE (Kuraray) (CSE and ESE). All 40 restored teeth were cut yielding stick-shapped samples with a cross-sectional area of approximately 1.0 mm2 and were submitted to a micro-tensile force running at a crosshead speed of 0.5 mm/min until fracture. Statistic results showed significant difference among the groups (using the ANOVA test F= 4,643). The eroded dentin samples submitted to surface treatment with Clearfill SE (ECF) prior to restoration showed significantly higher bond strength results when compared to all the other groups (m=42.16 ±20.509 Mpa) (p=0,0082).
|
Page generated in 0.4125 seconds