• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência das bainhas na resistência das almas das vigas de concreto protendido

Fairbairn, Eduardo de Moraes Rego 03 1900 (has links)
Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-09-25T17:30:28Z No. of bitstreams: 1 147039.pdf: 1130687 bytes, checksum: cfc5ec5f01b11ca54b6542b1b2522c6a (MD5) / Made available in DSpace on 2017-09-25T17:30:28Z (GMT). No. of bitstreams: 1 147039.pdf: 1130687 bytes, checksum: cfc5ec5f01b11ca54b6542b1b2522c6a (MD5) Previous issue date: 1978-03 / As recomendações do CEB preconizam que no caso da verificação da resistência das almas das vigas de Concreto Protendido ao esforço cortante, deve ser levada em conta a espessura efetiva da alma (deduzindo metade do somatório dos diâmetros das bainhas) na região considerada (bwef = bw - 1/2 ∑Ф). Com o intuito de verificar esta recomendação, foram ensaiadas até à ruptura por esmagamento da biela 15 vigas de concreto armado. Todas as vigas tinham as mesmas características geométricas e a mesma armadura longitudinal e transversal. Os únicos parâmetros variados foram os diâmetros das bainhas e a injeção ou não destas com pasta de cimento. Concluímos que para os casos em que podemos confiar na eficiência da injeção não seria necessária uma redução do valor da espessura da alma e que para os casos em que a total eficiência da injeção não pode ser levada em conta, é recomendável a redução apresentada pelo CEB-1978 com bwef=bw-1/2∑Ф. / CEB Recommendations preconize that in case of verification of the web strength of the prestressed concrete bearns against the shear force, it might be taken into account the effective web thickness (by deduction of the half sum of the ducts diameters) in the considered region (bwef = bw - 1/2 ∑Ф). With the purpose of verifying this recommendation, fifteen reinforced concrete beams were tested until the crushing of the concrete web, in the direction of the diagonal cracks. The beams had the same geometrical charactheristics and the sarne transversal and longitudinal reinforcement. The variable parameters were the diameters of the ducts and their injection, or not, with mortar. We have concluded that in the cases in which the injection is reliable, a reduction of the value of the web thickness would not be necessary, and that in the cases in which the full efficiency of the injection cannot be trusted, the reduction preconized by CEB-1978 (bwef=bw-1/2∑Ф) is recommended.

Page generated in 0.0675 seconds