• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação simultânea de propifenazona, paracetamol e cafeína utilizando eletrodo de diamante dopado com boro

Silva, Weberson Pereira da 16 February 2017 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / No presente trabalho investigou-se o desenvolvimento de novos procedimentos analíticos para a determinação simultânea de paracetamol (PAR), propifenazona (PRO) e cafeína (CAF) em formulações farmacêuticas. Três métodos foram desenvolvidos usando as técnicas de voltametria de onda quadrada (SWV) e amperometria de múltiplos pulsos (MPA) e diamante dopado com boro (BDD) como eletrodo de trabalho. Empregando a SWV, duas estratégias de análise foram desenvolvidas: (I) uso de uma célula eletroquímica convencional (modo estacionário) e o método de adição de padrão; (II) uso de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) e o método de calibração externa. Os métodos propostos foram desenvolvidos usando como eletrólito de suporte H2SO4 0,1 mol L-1 e os parâmetros otimizados da SWV foram: potencial de condicionamento: -1,5 V durante 20 s; frequência: 60 s-1; amplitude: 50 mV e incremento de potencial: 4 mV. No método proposto empregando BIA-SWV, o volume e a velocidade de injeção otimizados foram de 100 μL e 28 μL s-1, respectivamente. Um terceiro método proposto para determinação simultânea de PAR, PRO e CAF, o procedimento de análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) foi empregado. Três pulsos de potenciais foram selecionados para realização da análise: +0,90 V /50 ms: apenas o PAR foi oxidado sem a interferência dos outros dois compostos; +1,20 V /50 ms: oxidação do PAR e da PRO livre da interferência da CAF; +1,60 V /50 ms: oxidação dos três compostos (PAR, PRO e CAF). A seletividade na detecção da PRO e CAF foi obtida mediante subtração de correntes entre os amperogramas adquiridos nos potenciais selecionados e o uso de fatores de correção (FCs). Todos os procedimentos de análise desenvolvidos mostraram-se estáveis (DPR < 4,1%) e lineares (r > 0,997). O método empregando uma célula eletroquímica convencional apresentou frequência analítica de 20 análises h-1 e limites de detecção de 0,005, 0,009 e 0,006 mg L-1 para PAR, PRO e CAF, respectivamente. Os métodos BIA-SWV e BIA-MPA apresentaram frequência analítica muito superior: 80 e 75 análises h-1, respectivamente. Os limites de detecção foram de 0,3, 0,2 e 0,3 mg L-1 (BIA-SWV) e 0,2, 0,3 e 0,1 mg L-1 (BIA-MPA) para PAR, PRO e CAF, respectivamente. / In this work we investigated the development of new analytical procedures for simultaneous determination of paracetamol (PAR), propyphenazone (PRO) and caffeine (CAF) in pharmaceutical formulations. Three methods was developed using of Square wave voltammetry (SWV), multiple pulse amperometry (MPA) and boron doped diamond (BDD) with work electrode. Employing SWV, two analysis strategies were developed (I) Use of a conventional electrochemical cell (stationary mode) and the standard addition method; (II) use of batch injection analysis with detection by square wave voltammetry (BIA-SWV) and external calibration method. The proposed methods were developed using H2SO4 0.1 mol L-1 as supporting electrolyte and optimized parameters of the SWV: Conditioning potential: -1.5 V during 20 s; frequency: 60 s-1; amplitude: 50 mV and step potential: 4 mV. In the proposed method using BIA-SWV, volume and speed of optimized injection were 100 μL e 28 μL s-1, respectively. On the third method proposed for simultaneous determination of the PAR, PRO and CAF, the batch injection analysis procedure with multiple pulse amperometry detection (BIA-MPA) was employed. Three potentials pulses were selected for the analysis: +0.90 V/50 ms: only PAR was oxidized without the interference of the other two compounds; +1.20 V/50 ms: oxidation PAR and PRO without the interference of the CAF; +1.60 V/50 ms: oxidation of the three compounds (PAR, PRO and CAF). The selectivity in the detection of PRO and CAF was obtained by subtracting currents between the amperograms acquired in the selected potentials and the use of correction factors (CFs). All developed analysis procedures remained stable (RSD < 4.1%) and linear (r > 0.997). The method using a conventional electrochemical cell showed an analytical frequency of 20 analysis h-1 and limits of detection of 0.005, 0.009, and 0.006 mg L-1 for PAR, PRO, and CAF, respectively. The BIA-SWV and BIA-MPA methods presented higher analytical frequency: 80 and 75 analysis h-1, respectively. The limits of detection were 0.3, 0.2, and 0.3 mg L-1 (BIA-SWV) and 0.2, 0.3, and 0.1 mg L-1 (BIA-MPA) for PAR, PRO and CAF, respectively. / Dissertação (Mestrado)
2

Uso do método do padrão interno em sistemas FIA e BIA e determinação simultânea de diclofenaco e codeína em formulações farmacêuticas por amperometria de múltiplos pulsos / Use of the internal standard method in FIA and BIA systems and determination of diclofenac and codeine in pharmaceutical formulations by multiple pulse amperometry

Gimenes, Denise Tofanello 25 July 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present thesis demonstrates, for the first time, the possibility of using of the internal standard method in FIA or BIA systems with amperometric detection. The method allows to obtain accurate results in the presence of fluctuations in the system parameters (injected volume, dispensing rate, ionic strength and accidental insertion of air bubbles) and in the presence of contamination and/or gradual passivation of the working electrode surface. Methods for determination of diclofenac (DCF) using FIA with amperometric detection and simultaneous determination of DCF and codeine (CO) by BIA with amperometric detection have also been developed. The internal standard method was implemented in the flow injection analysis with multiple pulse amperometric detection (FIA-MPA) system by applying a sequence of potential pulses of the working electrode as a function of time. The analyte (+0.80 V/300ms) and internal standard (-0.05 V/400ms) were detected selectively, one at each potential pulse. Significant improvements were obtained in the accuracy of the system when the results before and after normalization (using the internal standard method), were compared. The following errors were calculated, respectively, before and after normalization of the results using the internal standard method. Change in flow rate from 3.0 to 1.0 ml min-1 (-57% e < 1%); volume injection from 300 to 100 &#956;L (-63% and 3%); ionic strength from 0.60 to 0.77 mol L-1 (-44 and 0,2%) and before and after the introduction of air bubbles into the system (-9,6% and 1,7%). A significant improvement was also obtained in the correlation coefficient of the calibration curve in the presence of problems of passivation or contamination of the working electrode. The correlation coefficient was calculated, respectively, as 0,975 and 0,998, before and after the normalization of the results by the IS method. The internal standard method was also applied to correct errors derived from the injection procedure (dispensing rate and injected volume) in batch injection analysis systems (BIA) with amperometric detection when disposable syringes were used. The results obtained before and after normalization of the results by the IS method were the following, respectively: repeatability test (RSD = 6.4 and 1.8%; n = 8), correlation coefficients (R=0.954 and 0.997) and errors obtained in analysis of synthetic samples (E = 9.4 ± 1.5 and 3.5 ± 0.7%; n = 8). The determination of DCF by FIA-MPA was implemented by applying two potential pulses to the BDD electrode using H2SO4 0.1 mol L-1 as supporting electrolyte: (i) + 1.2 V / 50 ms for oxidation and quantification of DCF, and (ii) 0.0 V / 50 ms for constant electrochemical cleaning of the electrode surface. The system showed good stability (RSD = 1.0%, n = 10) and high analytical frequency (135 injections h-1). The method showed a linear response between 5 and 50 &#956;mol L-1 and the detection and quantification limits were as 0.14 and 0.46 mmol L-1, respectively. The proposed method was applied to determine of DCF in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. The simultaneous determination of DCF and CO was performed using the following potential pulses: (i) +1.1 V / 50 ms: oxidation and quantification of DCF; (ii) +1.4 V / 50 ms: simultaneous oxidation of DCF and CO, (iii) 0.0 V / 200 ms: for constant electrochemical cleaning of the BDD electrode. The oxidation current from CO was obtained by the difference between currents detected at 1.4 and 1.1 V by using a correction factor. The system showed good stability (RSD = 0.9% and 1.1 for DCF and CO respectively, n = 10) and high analytical frequency (~ 300 injections h-1). The method showed a linear response between 10 and 50 &#956;mol L-1 for DCF and 7.1 and 35.7 &#956;mol L-1 for CO. The LQ and LD were calculated, respectively, at 1.1 and 3.7 &#956;mol L-1, for DCF and 1.0 and 3.3 mol L-1 for CO. The proposed method was applied for simultaneous determination of DCF and CO in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. Keywords: Multiple pulse amperometry, FIA, BIA, internal standard, simultaneous analysis, boron doped diamond (BDD), codeine, diclofenac. / Esta tese apresenta, pela primeira vez, a possibilidade de usar o método do padrão interno em sistemas FIA ou BIA com detecção amperométrica. O método permite a obtenção de resultados precisos na presença de flutuações em parâmetros dos sistemas (volume injetado, velocidade de injeção, força iônica e inserção acidental de bolhas de ar) e na presença de contaminação e/ou passivação gradual do eletrodo de trabalho. Métodos para determinação de diclofenaco (DCF) usando FIA com detecção amperométrica e simultânea de DCF e codeína (CO) por BIA com detecção amperométrica também foram desenvolvidos. O método do padrão interno foi implementado no sistema de análise por injeção em fluxo com detecção por amperometria de múltiplos pulsos (FIA-MPA) mediante a aplicação de uma sequência de pulsos de potenciais ao eletrodo de trabalho em função do tempo. O analito (+0,80 V/300ms) e o padrão interno (-0,05 V/400ms) foram detectados seletivamente, um em cada pulso de potencial. Melhoras significativas foram obtidas na precisão do método quando os resultados obtidos antes e após a normalização (usando o método do padrão interno) foram comparados. As seguintes variações foram calculadas, respectivamente, antes e após a normalização dos resultados usando o método do padrão interno. Variação na velocidade de vazão de 3,0 para 1,0 mL min-1 (-57% e < 1%); no volume de injeção de 300 para 100 &#956;L (-63% e 3%); força iônica de 0,60 para 0,77 mol L-1 (-44 e 0,2%) e antes e após a inserção de bolhas de ar no sistema (-9,6% e 1,7%). Uma melhora significativa também foi obtida no coeficiente de correlação da curva de calibração na presença de problemas de passivação ou contaminação do eletrodo de trabalho. O coeficiente de correlação foi calculado, respectivamente, em 0,975 e 0,998, antes e após a normalização dos resultados pelo método do PI. O método do padrão interno também foi aplicado para corrigir erros em sistemas de análise por injeção em batelada (BIA) com detecção amperométrica provenientes do procedimento de injeção (velocidade de injeção e volume injetado) quando seringas descartáveis foram utilizadas. Os resultados obtidos antes e após a normalização dos resultados pelo método do PI foram os seguintes, respectivamente: estudo de repetibilidade (DPR=6,4 e 1,8%; n = 8), coeficientes de correlação (R=0,954 e 0,997) e erros obtidos na análise de amostras sintéticas (9,4 ± 1,5% e 3,5 ± 0,7; n = 8). A determinação de DCF por FIA-MPA foi implementada através da aplicação de dois pulsos de potenciais ao eletrodo de BDD em meio de H2SO4 0,1 mol L-1 como eletrólito suporte: (i) +1,2 V / 50 ms para oxidação e quantificação do DCF e, (ii) 0,0 V / 50 ms para constante limpeza eletroquímica do eletrodo de trabalho. O sistema apresentou boa estabilidade (RSD = 1,0%; n=10) e elevada frequência analítica (135 injeções h-1). O método apresentou resposta linear entre 5 e 50 &#956;mol L-1 e os limites de detecção e quantificação foram calculados em 0,14 e 0,46 &#956;mol L-1, respectivamente. O método proposto foi aplicado na determinação de DCF em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. A determinação simultânea de DCF e CO foi realizada usando os seguintes pulsos de potenciais: (i) +1,1 V / 50 ms: oxidação e quantificação de DCF; (ii) +1,4 V / 50 ms: para oxidação simultânea de DCF e CO; (iii) 0,0 V / 200 ms: para constante limpeza eletroquímica do eletrodo de BDD. A corrente de oxidação da CO foi obtida pela subtração entre as correntes detectadas em 1,4 e 1,1 V mediante uso de um fator de correção. O sistema apresentou boa estabilidade (RSD= 1,1 e 0,9% para DCF e CO, respectivamente, n=10) e elevada frequência analítica (~300 injeções h-1). O método apresentou resposta linear entre 10 e 50 &#956;mol L-1 para o DCF e entre 7,1 e 35,7 &#956;mol L-1 para CO. O LD e o LQ foram calculados, respectivamente, em 1,1 e 3,7 &#956;mol L-1, para DCF e 1,0 e 3,3 &#956;mol L-1 para CO. O método proposto foi aplicado na determinação simultânea de DCF e CO em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. / Doutor em Química

Page generated in 0.0768 seconds