• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analise vibracional de alguns sais de litio monohidratados utilizando-se efeitos isotopicos

Hase, Yoshiyuki, 1948- 18 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Instituto de Quimica / Acompanha memorial / Made available in DSpace on 2018-07-18T02:49:35Z (GMT). No. of bitstreams: 1 Hase_Yoshiyuki_LD.pdf: 3506412 bytes, checksum: b09f17a7fdcc735055d94dfe60fe4631 (MD5) Previous issue date: 1984 / Tese (livre-docencia) - Univer
2

Distribuição da marcação com nitrogenio 15 de frações proteicas de feijão-comum (Phaseolus vulgars L.) e diluição isotopica no processo de digestibilidade in vitro / Distribution of the marking with nitrogen 15 of protéicas fractions of beans-common (PHASEOLUS VULGARIS, L.) e isotópica dilution in the digestibilidade process in vitro

Chaud, Saula Goulart 24 November 1998 (has links)
Orientador: Admar Costa de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-24T13:58:49Z (GMT). No. of bitstreams: 1 Chaud_SaulaGoulart_M.pdf: 332493 bytes, checksum: 6af27b91ff356a97613c1bb79f7747a9 (MD5) Previous issue date: 1998 / Resumo: O presente trabalho teve por objetivo verificar se a marcação com nitrogênio 15 (15N) de feijão integral, liofilizado, marcado isotopicamente com 1,385 átomos%, é a mesma na proteína e frações protéicas extraídas do feijão, assim como verificar a diluição isotópica do 15N ocorrida na digestibilidade in vitro, pela autodigestão das enzimas utilizadas. As proteínas foram extraídas com NaCl 0,5M em pH 7,0. Na avaliação da digestibilidade in vitro, utilizou-se o método da hidrólise pela pepsina mais pancreatina. As marcações isotópicas na farinha integral de feijão, o extrato protéico total, a fração globulina e a fração albumina foram, respectivamente: 1,394±0,011; 1,403±0,012; 1,399±0,007 e 1,399±0,028 átomos% de 15N, não sendo encontrada diferença estatística entre as mesmas (P>0,05). Entretanto, foram encontradas diferenças significativas (P<0,05) entre as marcações acima citadas e a marcação isotópica encontrada para o resíduo da extração, que foi de 0,969±0,084 e o nitrogênio originalmente solúvel, que apresentou um valor de 0,923±0,007 átomos% 15N. O digerido da farinha integral apresentou um valor de 1,026±0,014 átomos% de 15N, o que indica que efetivamente ocorreu autodigestão relativamente alta das enzimas utilizadas para a obtenção da digestibilidade in vitro, uma vez que não estão marcadas e, conseqüentemente, foram em parte responsáveis pela diluição isotópica encontrada. A diluição isotópica encontrada nas substâncias nitrogenadas existentes no digerido do branco da farinha integral, indicou que tais substâncias são marcadas em menor magnitude do que o próprio grão e suas proteínas, o que também influiu no resultado do digerido da farinha integral. O digerido do extrato protéico total apresentou um valor de 1,067±0,009. Os valores estão indicando a existência de diluição isotópica dos digeridos da farinha integral e do extrato protéico total, em relação à marcação isotópica da farinha e frações protéicas originais, aparentemente devido à autodigestão das enzimas e, em parte, ao nitrogênio originalmente solúvel da amostra, conforme descrito. A fim de monitorar os processos de extração e fracionamento das proteinas, foi determianda a metionina disponível in vitro, utilizando-se a reação do nitroprussiato de sódio. Os valores encontrados foram: farinha integral 0,30±0,04; extrato protéico 0,41±0,01; albumina 0,37±0,01 e globulina 0,41±0,05 g/100g proteína, que estão de acordo com resultados usualmente encontrados na literatura. Como conclusão geral, pôde ser inferido que os índices de qualidade protéica, como a digestibilidade e o valor biológico por balanço de nitrogênio e diluição isotópica, não serão afetados no caso de proteínas extraídas do feijão com NaCl 0,5M, uma vez que a marcação isotópica (15N) da farinha integral e frações protéicas não diferiram (p > 0,05). No caso de se trabalhar com farinhas integrais, estes índices poderão apresentar resultados irreais, uma vez que as marcações isotópicas tanto do nitrogênio do resíduo de extração como do nitrogênio originalmente solúvel foram menores / Abstract: The aim of the present work was to verify if the isotope labelling with nitrogen 15 (15N) obtained in whole lyophilized beans, which had been labelled isotopically with 1.385% of 15N atoms of the total, was the same in the protein and protein fractions extracted from the beans. The aim was also to verify isotopic dilution of 15N, which occurs during in vitro digestibility through selfdigestion of the enzymes used. Proteins were extracted using 0.5M NaCl at pH 7.0. In order to assess digestibility in vitro the hydrolysis method was applied using pepsin plus pancreatine. The isotope labelling of the whole bean flour, the total protein extract, the globulin fraction and the albumin fraction were, respectively: 1.394±0.011; 1.403±0.012; 1.399±0.007 and 1.399±0.028% of 15N atoms. No statistical difference was found between these data (P>0.05). Nevertheless, significant differences (P<0.05) were found between the isotopic labelling mentioned above and those found for the extraction residue which was 0.969±0.084 and the original soluble nitrogen which showed a value of 0.923±0.007% 15N atoms. The in vitro digested part of the whole flour showed a value of 1.026±0.014 atoms of 15N, which indicates a relatively high selfdigestion by the enzymes used in the in vitro digestibility, since they had not been labeled and consequently were in part responsible for the isotopic dilution found. The isotopic dilution found in the nitrogen substances of the blank of the digested whole flour showed that such substances were less marked than the grain and its proteins which also had an influence on the digested fraction of the whole flour. The digested fraction of the total protein extract showed a result of 1.067±0.009. The values pointed out to the occurrence of isotopic dilution of the digested fractions of the whole flour and the total protein extract, in relation to the isotope label of the original flour and protein fractions, which is apparently due to selfdigestion by the enzymes used and to the original soluble nitrogen as a flour, as already described. In order to control the extraction and fragmentation processes of proteins, the in vitro methionine available was determined, using the reaction of sodium nitroprusside. The values found were: whole flour 0.30±0.04; protein extract 0.41±0.01; albumin fraction 0.37±0.01 and globulin fraction 0.41±0.05 g/100g protein, which correspond to results usually found in the literature. Concluding, it can be inferred that the protein quality indexes, such as digestibility and biological value using nitrogen balance and isotopic dilution, will not be affected in the case of bean proteins extracted by 0.5M NaCl, since isotopic labelling (15N) of the whole flour and protein fractions did not differ (p>0.05). However, in the case of whole flours, these indexes might produce false results, since the isotope labelling of both residual nitrogen extraction and the original soluble nitrogen were lower than those referred above / Mestrado / Mestre em Ciência da Nutrição
3

Determinação de elementos-traço em águas e rochas por ICP-MS quadrupolar com cela de colisão / Trace elements determination in water and rocks by quadrupole ICP-MS with collision cell

Cotta, Aloísio José Bueno 17 August 2018 (has links)
Orientador: Jacinta Enzweiler / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Geociências / Made available in DSpace on 2018-08-17T09:52:02Z (GMT). No. of bitstreams: 1 Cotta_AloisioJoseBueno_D.pdf: 12674950 bytes, checksum: 5c83c715500dcc83803f8d9b7d8712f1 (MD5) Previous issue date: 2010 / Resumo: A espectrometria de massas com plasma indutivamente acoplado (ICP-MS) possibilita determinações multielementares rápidas e com baixos limites de detecção numa variedade de matrizes, dentre elas as geológicas. Neste estudo, métodos comparativos utilizando um ICP-MS quadrupolar equipado com cela de colisão (CC) foram estabelecidos para determinar amplos conjuntos de elementos-traços em águas e em rochas. A aplicabilidade e as limitações da CC para atenuar interferências poliatômicas sobre os isótopos empregados foram amplamente investigadas. Em condições ótimas, muitas interferências puderam ser eliminadas ou significativamente atenuadas, o que tornou os métodos menos dependentes de correções matemáticas. Para a análise de rochas, técnicas clássicas de dissolução envolvendo misturas ácidas, como HF/HNO3, foram utilizadas e um novo procedimento com equipamento que possibilita efetuar a digestão sob pressão de até 13 MPa é proposto. Nesse caso, a precipitação de AlF3, o qual retém alguns elementos-traço, principalmente Co, Sr, Ba e Pb, foi o maior obstáculo à recuperação quantitativa dos analitos. A formação de AlF3 foi evitada com a adição de Mg à porção teste e com o controle da temperatura de digestão. A decomposição por sinterização com peróxido de sódio foi também investigada e verificou-se que a inclusão de uma etapa de aquecimento da dispersão resultante da dissolução do sinterizado em água, antes da separação do precipitado de hidróxidos de Fe e Ti, o qual retém os elementos-traço, auxilia na coprecipitação de Ni, Zr, Nb, Cd, Sn, Sb, Hf, Pb e Th e permite acrescentá-los à lista de elementos determináveis. Os métodos foram validados pela análise de um conjunto de materiais de referência (MR), alguns deles certificados. Os resultados obtidos demonstraram que os métodos desenvolvidos para águas e rochas apresentaram tendência e coeficientes de variação menores que 5% para a maior parte dos mensurandos. Os resultados obtidos para os MR certificados de rochas, BRP-1 e OU-6, foram utilizados para calcular a incerteza do método ao nível aproximado de confiança de 95%. A técnica de diluição isotópica foi aplicada para determinar Cr, Ni, Cu, Zn, Sr e Sn em alguns MR de rochas em uso e em candidatos a MR, com o objetivo de estabelecer o método e contribuir com novos valores para esses MR. As incertezas de todas as etapas do procedimento foram estimadas. Os resultados obtidos evidenciam que o valor certificado de Cr em BRP-1 deveria ser revisto e confirmam a necessidade do estabelecimento da rastreabilidade metrológica durante a certificação de MR. / Abstract: Inductively coupled plasma mass spectrometry (ICP-MS) is suited for fast multi-trace element determinations with low detection limits in a variety of matrices, including geological samples. In this study we established comparative analytical methods for the determination of an expressive number of trace elements in water and rock samples using an ICP-MS equipped with collision cell (CC). The applicability and limitations of CC for polyatomic interference attenuation over the isotopes used were widely investigated. Under optimized conditions, many interferences were eliminated or significantly attenuated, so these methods depend less on mathematical corrections. For rock analyses, classical multi-acid decomposition techniques, with mixtures like HF/HNO3, were used, and a new procedure with equipment that allows digestion at 13 MPa is proposed. In this case, the precipitation of AlF3, which retains some trace elements like Co, Sr, Ba and Pb preferentially, was the major drawback in achieving quantitative recoveries. The formation of AlF3 was inhibited by adding Mg to the test portion and controlling the temperature of digestion. Sample decomposition by sintering with sodium peroxide was also tested and was demonstrated that including a heating step of the sinter dispersion obtained after dissolution in water and before the separation of the precipitated Fe and Ti hydroxides, which retain many trace elements, helps to achieve a quantitative co-precipiation of Ni, Zr, Nb, Cd, Sn, Sb, Hf, Pb and Th and allows to include them to the list of determinable elements. The methods were validated by analysis of a set of reference materials (RM) some of them certified. Relative standard deviations and bias of the results were less than 5% for most of the measurands. The results obtained for the certified RM BRP-1 and OU-6 were used to calculate the measurement uncertainty at the approximate 95% confidence interval. The isotope dilution technique was applied to determine Cr, Ni, Cu, Zn, Sr and Sn in some geochemical RM in use and in candidate RM, with the objective of establishing the method to contribute with new values for the analysed RM. The uncertainties of the whole analytical procedure were estimated. The results obtained show that the certified value of Cr in BRP-1 should be reviewed and confirm the need of establishing the metrological traceability during the certification of RM. / Doutorado / Geologia e Recursos Naturais / Doutor em Ciências

Page generated in 0.1214 seconds