Spelling suggestions: "subject:"ancoragem ortodôntico"" "subject:"ancoragem ortodônticos""
21 |
Influência do diâmetro, comprimento e angulação nos torques de inserção e remoção de mini-implantes autoperfurantes /Pignatta, Lilian Maria Brisque. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Francisco Antonio Bertoz / Banca: Marcos Rogério de Mendonça / Banca: Paulo Henrique dos Santos / Banca: Maurício Tatsuei Sakima / Banca: Júlio de Araújo Gurgel / Resumo: Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações / Abstract: Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles / Doutor
|
22 |
Estudo comparativo da retenção das bandas ortodônticas Grip Tite, convencional e convencional com a superfície interna microjateada por óxido de alumínioVargas, Deborah Bayer Ferraz [UNESP] January 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0
Previous issue date: 2007Bitstream added on 2014-06-13T18:56:43Z : No. of bitstreams: 1
vargas_dbf_me_arafo.pdf: 680704 bytes, checksum: b86da5b28576f3b91eb2292fc618c8b8 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo do presente trabalho foi avaliar in vitro, por meio de um ensaio mecânico, a força necessária para a remoção das bandas ortodônticas Grip Tite (C), Convencional (A) e banda Convencional com a superfície interna microjateada por óxido de alumínio (B). Também analisar visualmente a quantidade de cimento residual, e classificar usando uma escala de incrementos a 25%. Após, verificar, por meio de MEV, a superfície com melhores características para a retenção. Os resultados obtidos mostraram que a média de carga do Grupo B, bandas microjateadas internamente por óxido de alumínio, foi significantemente maior que as médias dos Grupos A, bandas Convencionais, e C, bandas Grip Tite. Quanto a quantidade de cimento remanescente nas bandas, o Grupo B apresentou 100% das bandas com índice 4, indicando a presença de mais de 75% de cimento residual nas bandas, enquanto que nos Grupos A e C, houve a predominância do índice 1, indicativo de menos de 25% de cimento residual nas bandas, sem diferença significativa entre esses dois grupos. Os resultados foram confirmados pela MEV, onde observou-se uma superfície com melhores características para a retenção do cimento nas bandas onde foi realizado o processo de microjateamento. Conclui-se que o processo de microjateamento por óxido de alumínio, na superfície interna das bandas convencionais, aumenta a força necessária para a remoção das bandas e aumenta a quantidade de cimento residual preso à superfície da banda. Quando analisada pela MEV, essa superfície apresenta-se como a mais áspera e rugosa, com a maior quantidade de cimento de ionômero de vidro aderido à banda. / The purpose of this study was to evaluate in vitro, the necessary force for the removal of Grip Tite, Conventional and Sandblasted orthodontics molar bands, as well as, to analyze and to classify the amount of residual cement in the internal surface of these bands. After that, checking through scanning electron microscopy, the surface with better characteristics for the retention. The obtained results showed that the load average of the group B, Sandblasted bands, was significantly higher than the group A, Conventional bands, and C, Grip Tite bands. Observing the amount of remaining cement in the bands, group B presented 100% of the bands with index 4, indicating the presence of more than 75% of residual cement in the bands, while in the groups A and C, had the predominance of index 1, indicative of less than 25% of residual cement in the bands, without significant difference between these two groups. The results were confirmed by the scanning electronic microscopy, where the surface with better characteristics for the retention of the cement was observed, in the bands where the sandblasted process was carried through. It was concluded that the process of sandblasted, in the internal surface of the conventional bands, increases the necessary force for the removal of the bands and increases the amount of residual cement in the internal surface of the band. When analyzed by the scanning electronic microscopy, this surface appeared rougher and corrugated, with great amount of glass ionomer cement adhered to the band.
|
23 |
Avaliação da resistência ao arrancamento de mini-implantes ortodônticos: estudo laboratorialGouvêa, Carla Corrêa Mendes [UNESP] 07 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-10-07Bitstream added on 2014-06-13T20:17:27Z : No. of bitstreams: 1
gouvea_ccm_me_araca.pdf: 929518 bytes, checksum: 1d39d7891d1bd1d3169ca5b03ea750f2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Sin Implantes / Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal – EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine – EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability
|
24 |
Avaliação da resistência ao arrancamento de mini-implantes ortodônticos : estudo laboratorial /Gouvêa, Carla Corrêa Mendes. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Paulo Henrique dos Santos / Banca: Francisco Antonio Bertoz / Banca: José Fernando Castanha Henriques / Resumo: Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal - EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Abstract: Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine - EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability / Mestre
|
25 |
Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores : estudo prospectivo /Arantes, Flávia de Moraes. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Francisco Antônio Bertoz / Banca: Júlio de Araújo Gurgel / Banca: José Rino Neto / Banca: Marcos Roberto de Freitas / Resumo: A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba - UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste "t" pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste "t" de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba - UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages "Beginning" and "After", a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student's t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below) / Doutor
|
26 |
Comparação quantitativa da retração de caninos superiores utilizando dois sistemas de ancoragem /Kina, Juliana. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Marcos Rogério de Mendonça / Banca: João Batista de Paiva / Resumo: Introdução: Para a eficiência da ancoragem, diferentes protocolos são preconizados durante a mecânica ortodôntica, principalmente quando se deseja a retração inicial do canino para o alinhamento e nivelamento anterior sem a mesialização do segmento posterior. Nesse contexto, a utilização dos minimplantes tem sido cada vez mais frequente, pois possuem características desejáveis para essa finalidade como a facilidade operacional de sua instalação, dispensa a colaboração do paciente para o desenvolvimento da mecânica ortodôntica,é favorável na estética e permite um sistema de forças mais previsível. O objetivo deste trabalho foi comparar quantitativamente por meio de telerradiografias em norma lateral e radiografias panorâmicas, a taxa de retração inicial de caninos (RIC) superiores, utilizando-se dois sistemas distintos de ancoragem. Métodos: Foram selecionados 18 pacientes, formando dois grupos aleatórios de 9 indivíduos (G1 e G2), triados para tratamento ortodôntico na UNESP - Araçatuba. Como ancoragem foi utilizado minimplantes no grupo G1 e botão de Nance no grupo G2. Para todos os pacientes foram realizadas duas telerradiografias em norma lateral (T1 e T2) e duas panorâmicas (P1 e P2). Para comparação entre as fases Início (antes do tratamento) e Após (após a retração inicial de caninos) foi utilizado o teste t pareado. Para a comparação entre os grupos de minimplante e botão de Nance foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Resultados: Para a RIC no Grupo G1, obteve-se uma média de 0,63 mm/mês, enquanto para o grupo G2 a média foi de 0,56 mm/mês. Conclusões: A análise das telerradiografias em norma lateral e das radiografias panorâmicas revelou a inexistência de diferença estatisticamente significante entre os dois grupos. / Abstract: Introduction: For efficiency of the anchorage, different protocols are recommended during orthodontic mechanics, especially when clinicians want to retract the initial alignment and leveling without the inclination of the posterior segment. In this context, the use of mini-implants has been frequent. For this purpose it has desirable characteristics, such as the operational facility of installation, the collaboration of the patient, exemption for the development of orthodontic mechanics, it is favorable in appearance and allows more predictable system forces. This study compared, by teleradiographs and panoramic radiographs, the initial rate of retraction of canines (ICR), using two different systems of anchoring. Methods: 18 patients were selected and divided in two random groups of 9 subjects (G1 and G2). They needed and were refered to orthodontic treatment at UNESP - Araçatuba. In G1, mini-implants were used as anchor and G2 used the Nance button appliance. Two teleradiographs (T1 and T2) and two panoramic (P1 and P2) were made for all patients. The paired T test was used for comparison between Initial (before treatment) and After (after the initial retraction of canines) phases. Student's t test for independent measures was used for comparison between groups of mini-implants and the Nance button appliance. A significance level of 5% (p <0.05) was adopted in all tests. Results: For G1, an average of 0.63 mm / month was obtained, while for G2, the average was 0.56 mm / month. Conclusions: The analysis of teleradiographs and panoramic radiographs showed the absence of statistically significant difference between the two groups. / Mestre
|
27 |
Comparação tridimensional dos efeitos dentários de duas mecânicas para fechamento de espaço: estudo preliminar / Three-dimensional comparison of dental effects of two mechanics for space closure: a preliminary studyCamila de Sousa Dardengo 17 December 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As más oclusões de Classe I com biprotrusão dentária são caracterizadas pela projeção dos incisivos superiores e inferiores e podem ser corrigidas com extrações de primeiros pré-molares, permitindo reposicionar os incisivos, usando como ancoragem os dentes posteriores. Esse trabalho teve como objetivo comparar, por meio de superposição de modelos tridimensionais, a movimentação de molares e de incisivos com duas técnicas para fechamento de espaços. Foram selecionados, tomografados (T0) e distribuídos, aleatoriamente em dois grupos, seis pacientes com indicação de exodontia de quatro primeiros pré-molares. No grupo 1 (n=3) foi feito o fechamento dos espaços das extrações em uma única etapa (fechamento em massa) e no grupo 2 (n=3), em duas etapas (distalização de caninos seguida da retração de incisivos). Após o completo fechamento dos espaços foi solicitada nova tomografia (T1). Os modelos tridimensionais em T0 e T1 para os dois grupos foram superpostos para descrever e quantificar a movimentação ocorrida nos primeiros molares. A retração de incisivos foi avaliada de maneira bidimensional. Os molares superiores e inferiores do grupo 1 sofreram movimentação mesial de translação, enquanto os do grupo 2, apresentaram deslocamento de coroa maior do que de ápice radicular, demonstrando movimento de inclinação mesial de coroa. Ao se comparar o movimento mesial dos molares entre os dois grupos, observou-se que no grupo 1 houve maior movimentação mesial da raiz mésio-vestibular dos molares superiores (p=0,009). No entanto, em ambos os grupos os molares superiores giraram sobre a raiz palatina. No arco inferior verificou-se maior movimento mesial de coroa para o grupo 2 (p=0,015). A análise da movimentação dos incisivos apresentou variações semelhantes para as medidas lineares e angulares dos incisivos superiores nos dois grupos. Já, para as medidas angulares dos incisivos inferiores, observou-se que o grupo 1 apresentou menor controle de torque. O tempo de tratamento de todos os pacientes da amostra foi superior a 30 meses, exceto um paciente que apresentou tempo de tratamento inferior a 24 meses. Pôde-se concluir que a perda de ancoragem ocorreu por movimento de translação no fechamento de espaços em massa, e por inclinação mesial no fechamento de espaços em duas etapas, para ambos os arcos. Parece haver maior movimentação mesial radicular nos molares superiores no fechamento em massa e maior movimento mesial de coroa dos molares inferiores para o fechamento em duas etapas. Sugere-se que não há diferença na retração dos incisivos superiores e maior retroinclinação dos incisivos inferiores no fechamento de espaços em duas etapas. / Class I malocclusions with dental biprotrusion are characterized by the projection of upper and lower incisors and can be corrected with extractions of four first premolars, allowing incisor retraction using the posterior teeth as anchorage. The purpose of this research was to compare the movement of molars and incisors, by superimpostions of three-dimensional models, with two space closure techniques. Six patients with indication for four first premolar extractions were selected, tomographed (T0) and randomly assigned to two groups. For Group 1 (n=3) premolar extraction space closure was performed in one-stage (en masse retraction) and for group 2 (n=3) in two stages (canine retraction followed by incisor retraction). After complete space closure, a new tomograph was taken (T1). The three-dimensional models, in T0 and T1, for both groups were superimposed to describe and quantify first molar movement. Incisor retraction was evaluated in two dimensions. The upper and lower molars in group 1 presented bodily mesial movement, while those in group 2, presented greater crown than root movement, demonstrating mesial crown tipping. When the amount of mesial molar movement was compared between the two groups, a greater mesial root movement was observed for upper molars in group 1 (p=0.009). However, in both groups the upper molars rotated aroung the palatal root. In the lower arch, a greater mesial crown movement was observed in group 2 (p=0.015). Incisor movement analysis presented similar variations for linear and angular measurements for upper incisors in both groups. In contrast, the angular measurements for the lower incisors demonstrated more torque control in group 2. The treatment time for all patients in the sample was greater than 30 months, with the exception of one patient, who presented treatment time smaller than 24 months. In conclusion, anchorage loss ocurred by bodily movement in en masse space closure and by mesial crown tipping in two-stage space closure, in both arches. In addition, there might be greater mesial root movement for upper molars in en masse space closure and greater mesial crown movement in two-stage space closure. It can also be suggested that there are no differences in upper incisor retraction and there is greater lower incisor uprighting in two-stage space closure.
|
28 |
Influência do padrão de crescimento sobre a espessura da cortical óssea alveolar e sua correlação com a estabilidade dos mini-implantes / Influence of growth pattern on the alveolar cortical bone thickness and the correlation with stability of mini-implantsCarolina Carmo de Menezes 18 February 2011 (has links)
O objetivo deste estudo foi avaliar a influência do padrão de crescimento craniofacial na espessura da cortical óssea alveolar e correlacioná-lo com a estabilidade dos mini-implantes ortodônticos. A amostra constituiu de 30 pacientes com 56 mini-implantes inseridos na região posterior vestibular da maxila como recurso de ancoragem na retração anterior. Inicialmente, os pacientes foram divididos de acordo com a média do ângulo FMA, em padrão de crescimento horizontal (grupo GH) e vertical (grupo GV). As espessuras das corticais ósseas foram mensuradas nos cortes axiais das imagens de tomografia computadorizada de feixe cônico. As médias econtradas em cada grupo foram comparadas pelo teste t. A correlação de Pearson foi realizada entre os valores do ângulo FMA e as espessuras das corticais ósseas. Posteriormente, para avaliar a influência do padrão de crescimento sobre a estabilidade dos mini-implantes, estes foram divididos em dois grupos também de acordo com o padrão de crescimento: GMI(H) horizontal e GMI(V) vertical. Os grupos foram comparados quanto ao grau de mobilidade e a proporção de sucesso dos mini-implantes pelos testes de Mann-Whitney e o teste Exato de Fisher. Através desses testes e do teste Qui-quadrado foi avaliada a influência das seguintes variáveis sobre o grau de estabilidade: características do tecido mole na região de inserção, sensibilidade, a quantidade de placa, o período de observação e a técnica utilizada para cada dispositivo. Os resultados obtidos demonstraram que a espessura da cortical óssea alveolar anterior (superior e inferior) e posterior (inferior) vestibulares foram maiores no grupo GH do que o grupo GV. Houve correlação negativa significante entre o FMA e as espessuras nas regiões anteriores inferiores (vestibular e lingual) e superior (vestibular). Não houve diferença significante nos resultados para o grau de mobilidade e proporção de sucesso dos mini-implantes nos grupos GMI(H) e GMI(V). O tempo médio de observação foi de 8,77 meses. A proporção de sucesso total foi de 89,29% e nenhuma variável mostrou estar relacionada com o sucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujo mini-implante apresentava mobilidade e a falha desses dispositivos de ancoragem ocorria logo após sua inserção. / This study aimed the assessment of the craniofacial growth pattern influence on the alveolar bone cortical thickness as well as the evaluation of the stability of orthodontic mini-implants. The sample comprised 56 mini-implants inserted on the posterior buccal region of the maxilla of 30 patients with the purpose of orthodontic anchorage for the anterior retraction. Initially, patients were divided by FMA mean according to the growth pattern as: horizontal group (GH group) and vertical group (GV group). The alveolar cortical bone thicknesses were measured in the axial sections of the images of cone-beam computed tomography. The means found for each group were compared with the t test. Pearson´s correlation was performed for the values of growth pattern (FMA) and for the thicknesses of cortical bone. In order to evaluate the influence of growth pattern on the stability of mini-implants, these devices were divided in two other groups, according to the growth pattern as: GMI(H), horizontal and GMI(V), vertical. The mobility degree and success rate of mini-implants shown by these two groups were compared using Mann-Whitney tests and Fisher Exact test. Through these tests and the Chi-square test the influence of the following variables on the degree of stability were evaluated: soft tissue characteristics of the insertion site, sensibility degree, plaque retention around miniimplant, observation period and technique used. The results demonstrated that the thickness of the anterior buccal cortical bone (upper and lower) and the posterior cortical bone (lower) were greater for the GH group than for the GV group. There was a significant negative correlation between the FMA and the thicknesses of the lower anterior regions (buccal and lingual) and upper regions (buccal). No significant difference was found regarding the mobility degree and the success rate of miniimplants between the groups GMI(H) and GMI(V). Total success rate found was 89.29% and no variable showed to be related to the success of mini-implants. Nevertheless, a greater sensibility was observed in patients whose mini-implants presented mobility and the failure of these anchorage devices occurred in a short time after insertion.
|
29 |
Avaliação da resistência a corrosão e da microestrutura de superfície de mini-implantes ortodônticos utilizadosCaetano, Paula Liparini 21 November 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-10T11:50:34Z
No. of bitstreams: 1
paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor verificar se Márcio realmente não tem acento - Primeiro Orientador: Campos, Marcio José da Silva
Favor corrigir o sobrenome composto: Sotto-Maior, Bruno Salles
Favor ferificar de Sérgio realmente não tem acento: Membro da banca: Mota Júnior, Sergio Lu on 2018-01-23T11:42:27Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:05:31Z
No. of bitstreams: 1
paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-24T13:32:58Z (GMT) No. of bitstreams: 1
paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Made available in DSpace on 2018-01-24T13:32:58Z (GMT). No. of bitstreams: 1
paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5)
Previous issue date: 2017-11-21 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Introdução: Os mini-implantes ortodônticos, como biomateriais, devem possuir, além de resistência mecânica, boa resistência à corrosão no meio fisiológico o qual estão inseridos. Objetivo: Avaliar a resistência à corrosão e a microestrutura de superfície de mini-implantes ortodônticos mantidos em seus sítios ósseos de inserção e removidos após sua utilização. Material e métodos: Foram avaliados vinte mini-implantes ortodônticos autoperfurantes de liga Ti6AI4V, divididos em 2 grupos de 10 unidades: grupo controle (como recebidos do fabricante) e grupo teste (que permaneceram estáveis em seus sítios ósseos de inserção e que foram removidos após sua utilização). Foi realizada a análise visual da superfície da rosca dos mini-implantes com microscópio eletrônico de varredura (MEV) e a avaliação da resistência à corrosão com o ensaio de polarização cíclica potenciodinâmica, onde foram determinados o OCP (potencial de circuito aberto), o tOCP (tempo de OCP), a ipp (corrente de passivação primária) e a Epp (potencial de passivação primário). Resultados: Não foi identificada diferença significativa entre os grupos para as variáveis estudadas, apesar de a comparação entre os valores de OCP ter tido um p-valor limite (p=0,050). As imagens de MEV da superfície de rosca dos mini-implantes do grupo controle e grupo teste obtidas demonstraram uma superfície polida e regular, sem presença de manchas ou partículas aderidas. Apenas um mini-implante do grupo controle apresentou em técnica auxiliar de espectrometria de energia dispersiva de raio-X (EDS) uma redução de 61% da concentração de titânio no interior da cavidade em relação à superfície do mini-implante), confirmando a imagem da microscopia eletrônica de varredura, a presença de um pite proveniente do processo de corrosão. Conclusão: A permanência média de 230 dias de mini-implantes ortodônticos fabricados com liga Ti6Al4V nos sítios ósseos de inserção não causou alterações significativas na resistência à corrosão e nas características superficiais destes dispositivos. / Introduction: The orthodontic mini-implants as biomaterials, in addition to mechanical resistance, shall have good corrosion resistance in the physiological environment in which they are inserted. Objective: To assess the corrosion resistance and the surface microstructure of orthodontic mini-implants kept in their bone insertion sites and removed after use. Material and methods: Twenty orthodontic mini-screw-implants made from Ti6AI4V alloy were assessed; divided into 2 groups of 10 units: the control group (as-received from the manufacturer) and the test group (which remained stable in their bone insertion sites and that have been removed after use). The visual analysis of the thread surface of mini-implants was performed with a scanning electron microscope (SEM) and the evaluation of corrosion resistance with the cyclic potentiodynamic polarisation test through which the open circuit potential (OCP), the tOCP (timing of OCP), the primary passivation current (ipp) and the primary passivation potential (Epp) were determined. Results: It has not been identified any significant difference between the groups for the studied variables, although the comparison between the OCP values has had a p-limit value (p = 0.050). SEM images of the thread surface of the mini-implants obtained from both groups showed a regular polished surface without the presence of stains or adhered particles. Only one mini-implant from the control group showed a 61% reduction in the concentration of titanium within the cavity compared to the surface of the mini-implant through an auxiliary spectrometry technique of energy dispersive x-ray (EDX), confirming the scanning electron microscopic image that shows the presence of pit from the corrosion process. Conclusion: The average stay of 230 days of orthodontic mini-implants made from Ti6Al4V alloy at bone insertion sites did not cause significant changes either in corrosion resistance nor superficial characteristics of these devices.
|
30 |
Monitoramento histológico, histomorfométrico e radiográfico da cicatrização óssea ao redor de mini-parafusos ortodônticos autoperfurantes, submetidos ou não à aplicação de carga imediata, em tíbias de coelhos / Histological, histomorphometric and radiographic monitoring of bone healing around self-drilling orthodontic mini-screws, subjected or not to immediate load in rabbit tibiaePriscilla Campanatti Chibebe Catharino 25 May 2012 (has links)
Mini-implantes ortodônticos são acessórios de ancoragem esquelética. O objetivo deste estudo foi descrever a cicatrização óssea inicial ao redor dos mini-implantes, esterilizados pelos pesquisadores, submetidos ou não à aplicação de carga imediata. Foram inseridos 144 mini-implantes autoperfurantes (TOMAS®, Dentaurum, Germany) nas tíbias de dezoito coelhos brancos. Carga imediata (50 cN) foi aplicada sobre 50% dos mini-implantes. Quatro coelhos foram sacrificados em cada tempo pós-cirúrgico: dias 15, 21, 30 e 60, e dois no dia 0, constituindo grupo controle. Radiografias digitais foram obtidas para mensuração da espessura da cortical óssea (ECO), contíguo aos mini-implantes e equidistante deles. Nas imagens digitais das lâminas histológicas, realizou-se análise histológica e histomorfométrica. Quantidade de osso (QO), contato osso-implante (BIC) e ECO foram analisados pelos testes t-pareado, ANOVA e coeficiente de correlação de Pearson. Aos 0 e 15 dias haviam áreas de fraturas da borda da cortical. Após 30 dias houve deposição de osso imaturo, que se apresentou maduro aos 60 dias. QO foi maior com carga aos 15 dias (p = 0,034); e aumentou ao longo da cicatrização, nos grupos com (p =0,004) e sem carga (p<0,001). Carga não afetou BIC; os valores aumentaram no decorrer do tempo, nos grupos com (p<0,001) e sem carga (p=0,001). ECO aumentou em todas as regiões (p<0,001). ECO próximo aos miniimplantes foi maior que no ponto médio, exceto aos 15 dias sem carga (p = 0.077). Concluiu-se que carga imediata leve não comprometeu a cicatrização óssea ao redor dos mini-implantes. Ósseointegração e o aumento da espessura da cortical óssea foram tempo-dependentes. / Mini-implants are attachments for orthodontic anchorage. This study aimed to describe the initial bone healing around mini-implants sterilized by the researchers, submitted or not to application of immediate loading. Were inserted 144 self-drilling mini-implants(TOMAS®, Dentaurum, Germany) in the tibia of eighteen white rabbits. Immediate loading (50 cN) was applied to 50% of mini-implants. The animals were sacrificed at each time post-surgery: day 15, 21, 30 and 60, and two on day 0, being the control group. Digital radiographs were obtained to measure the thickness of cortical bone (ECO), adjacent to mini-implants and equidistant from them. In digital pictures from histological slides histology and histomorphometry was analyzed. Amount of bone (QO), bone-implant contact (BIC) and ECO were analyzed by paired t-test, ANOVA and coefficient of Pearson correlation. At 0 and 15 days had shear areas. After 30 days there was deposition of immature bone, which appeared mature at 60 days. QO load was greater at 15 days (p = 0.034), and increased over healing in load (p = 0.004) and unloaded groups (p <0.001). Load affected BIC, the values increased over time in groups with load (p <0.001) and unloaded (p = 0.001). ECO increased in all regions (p <0.001). ECO near the mini-implants was greater than at midpoint, except for 15 days without load (p = 0,077). It was concluded that light immediate loading did not affect bone healing around the mini-implants. Osseointegration and increased cortical bone thickness were time-dependent.
|
Page generated in 0.0888 seconds