Avaliação dos torques para inserção, remoção e fratura de diferentes miniimplantes ortodônticos em cortical de tíbia bovina / Evaluation of the insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

Maria Fernanda Prates da Nova 22 February 2008 (has links)
A utilização de grupos de dentes ou de aparelhos dependentes de cooperação, como mecanismos de ancoragem, podem ser fatores limitantes para o sucesso de terapias ortodônticas. Tal fato incentivou a busca de métodos para ancoragem esquelética ou absoluta, que incluem os miniimplantes ortodônticos. Comercialmente estão disponíveis em diversas dimensões e desenhos, porém existem poucas informações sobre a relação de sua morfologia com falhas clínicas ou fraturas. O objetivo deste trabalho foi avaliar o comportamento de miniimplantes com formas diferentes para os seguintes fatores: (a) torque máximo de inserção, (b) torque máximo de remoção, (c) torque de fratura, (d) tipo de fratura, (e) tensão cisalhante e tensão normal. Foram utilizados 20 miniimplantes autoperfurantes, 10 da marca SIN e 10 da Neodent, com 1,6 mm diâmetro e com 8 e 7 mm de comprimento, respectivamente. Destes 10 miniimplantes, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando assim 4 grupos: SIN sem perfil (SSP), SIN com perfil (SCP), Neodent sem perfil (NSP) e Neodent com perfil (NCP). Todos os miniimplantes foram inseridos em cortical de tíbia bovina e depois removidos com micro-motor acoplado a um torquímetro digital que registrou os torques máximos de inserção e de remoção. Os miniimplantes que não fraturaram durante os ensaios de inserção e remoção foram submetidos ao ensaio de fratura realizado em máquina universal de ensaios Emic. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas foram comparados entre todos os grupos. O tipo de fratura foi avaliado pela tensão cisalhante e por avaliação em microscópio eletrônico de varredura (MEV). Para cada grupo comparou-se os torques de inserção e de remoção. Todas as comparações foram feitas através da ANOVA. Verificou-se que o grupo NCP apresentou torque máximo de inserção significativamente maior que os demais grupos (30,6 1,8 Ncm), porém todos fraturaram durante os ensaios de inserção (n=2) ou de remoção (n=3). Não houve diferença significativa entre os grupos para o torque de remoção. Apenas o grupo SSP apresentou diferença significativa entre os torques de inserção e de remoção, para o mesmo grupo. Para o grupo NSP o torque de fratura foi significativamente menor do que todos os outros grupos (27,42 1,14 Ncm). Não houve diferença significativa entre as tensões cisalhante e normal entre os grupos, demonstrando que todos os miniimplantes sofreram fratura do tipo dúctil, confirmado através do MEV. Uma vez que os miniimplantes de todos os grupos são confeccionados com a mesma liga metálica, variando apenas na forma, conclui-se que a resistência à fratura pode ser afetada por esta variável. / The use of groups of teeth or appliances which rely on patient compliance, as anchorage mechanisms, can be limiting factors for the success of orthodontic treatment. This fact encouraged the search for skeletal or absolute anchorage methods, which include orthodontic mini-implants. They are commercially available in different dimensions and designs, but there is scarce information regarding the relation between its morphology and clinical failures or fractures. The purpose of this study was to evaluate the behavior of mini-implants with different forms for the following factors: (a) maximum insertion torque, (b) maximum removal torque, (c) fracture torque, (d) type of fracture, (e) shear tension and (f) normal tension. Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6 mm in diameter and with 8 and 7 mm in length, respectively. Out of these 10 mini-implants, 5 did not have a neck and the other 5 had a 2 mm neck, and were separated into 4 groups: SIN without neck (SSP), SIN with neck (SCP), Neodent without neck (NSP) and Neodent with neck (NCP). All mini-implants were inserted in bovine tibia cortex and later removed with a low speed handpiece connected to a digital torquimeter, which recorded the maximum insertion and removal torques. The mini-implants that did not fracture during insertion and removal assays were submitted to the fracture test, performed in an EMIC universal test machine. The insertion, removal and fracture torques, as well as the calculated shear and normal tensions were compared between all groups. The type of fracture was assessed by the shear tension and by evaluation in scanning electronic microscope (SEM). Insertion and removal torques were compared for each group. All comparisons were done by ANOVA. The NCP group presented a significantly greater insertion torque than all other groups (30.6 1.8 Ncm), but all of them fractured during insertion (n=2) or removal (n=3). There were no significant differences between groups for removal torque. Only group SSP presented a significant difference between insertion and removal torques, for the same group. For group NSP, the fracture torque was significantly smaller than all other groups (27.42 1.14 Ncm). There was no significant difference between shear and normal tensions between groups, demonstrating that all mini-implants suffered ductile fracture, confirmed by SEM. Since mini-implants from all groups are made of the same alloy, varying only in form, one may conclude that resistance to fracture can be affected by this variable.
42

Avaliação cefalométrica comparativa do tratamento da má oclusão de classe II como Distalizador First Class em ancoragem convencional e esquelética / Comparative cephalometric evaluation of Class II malocclusion treatment with First Class distalizer in conventional and skeletal anchorage

Roberto Henrique da Costa Grec 27 April 2011 (has links)
O objetivo deste estudo prospectivo foi avaliar as alterações dentoesqueléticas e tegumentares de jovens com má oclusão de Classe II tratados com distalizador First Class em dois tipos diferentes de ancoragem. Foram selecionados 30 pacientes e divididos, aleatoriamente, em dois grupos de 15: G1 (5 masculino e 10 feminino) que recebeu o distalizador com ancoragem convencional no botão de Nance e G2 (10 masculino e 5 feminino) que recebeu o distalizador com ancoragem esquelética apoiado em 2 mini-implantes no palato, com médias de 13,00 e 13,28 anos de idade, respectivamente. As telerradiografias foram obtidas antes e após a distalização dos molares para a realização das análises cefalométricas. A análise estatística foi realizada pelo teste t dependente com a finalidade de verificar as alterações ocorridas dentro de um mesmo grupo e pelo teste t independente para verificar as diferenças entre os grupos. Foi calculado também o erro sistemático e casual. O tempo médio de tratamento foi de 4,51 e 6,28 meses para G1 e G2, respectivamente. Ambos os grupos apresentaram alterações dentárias significantes com distalização (G1=2,39 mm; G2=2,21 mm), angulação distal (G1=10,51º; G2=4,49º) e intrusão (G1=0,53 mm; G2=0,10 mm) dos primeiros molares superiores, sendo apenas sem significância a intrusão em G2. A perda de ancoragem foi semelhante entre os dois grupos, com significante mesialização (G1=2,78 mm; G2=3,11 mm) e angulação mesial (G1=4,95°; G2=4,69°) dos segundos pré-molares, protrusão (G1=1 ,55 mm; G2=1,94 mm) e vestibularização (G1=5,78°; G2=3,13°) significantes dos incisivos superiores e um aumento significante no trespasse horizontal (G1=1,07 mm; G2=0,81 mm). A mecânica de distalização não interferiu nos componentes esqueléticos e tegumentares dos pacientes. Em ambos os grupos, o distalizador First Class promoveu correção da relação molar, porém apresentou efeitos de perda de ancoragem verificada nos pré-molares e incisivos superiores mesmo quando associada à mini-implantes. Não houve diferença significante entre os grupos quanto às alterações dentárias lineares, porém as angulares foram significantemente menores no grupo com ancoragem esquelética. / The aim of this prospective study was to evaluate the dental, skeletal and soft tissue changes in youngsters with Class II malocclusion treated with First Class distalizer in two different types of anchorage. Thirty patients were included and divided, randomly, in two groups of 15. G1 (5 boys and 10 girls) that received distalizers with conventional anchorage (Nance button) and G2 (10 boys and 5 girls) that received distalizers with skeletal anchorage supported in two palatal mini-implants, average age of 13.00 and 13.28 years old, respectively. Lateral cephalometric radiographs were taken before and after molar distalization in order to the cephalometric analysis. Statistical analysis was performed by dependent t test to verify the changes occurred in the same group and by independent t test to verify the difference between the groups. The systematic and casual errors were calculated as well. The mean treatment period was 4.51 and 6.28 months for G1 and G2, respectively. Both groups showed significant dental changes with distalization (G1=2.39 mm; G2=2.21 mm), distal tipping (G1=10.51º; G2=4.49º) and intrusion (G1=0.53 mm; G2=0.10 mm) of maxillary first molars, just intrusion in G2 was not significant. Anchorage loss showed similar in both groups with significant mesialization (G1=2.78 mm; G2=3.11 mm) and mesial tipping (G1=4.95°; G2=4.69°) of maxillary second premolars, significant protrusion (G1=1.55 mm; G2=1.94 mm) and proclination (G1=5.78°; G2=3.13°) of maxillary incisors and significant increase in overjet (G1=1.07 mm; G2=0.81 mm). Distalization mechanic did not interfere in skeletal and soft tissue measurements of patients. In both groups, the First Class distalizer corrected the molar relationship, however it showed anchorage loss effects in maxillary premolars and incisors even when associated to mini-implants. There was no significant difference between the groups on dental linear changes, however the dental angular changes were significantly lower in skeletal anchorage group.
43

Avaliação dos torques para inserção, remoção e fratura de diferentes miniimplantes ortodônticos em cortical de tíbia bovina / Evaluation of the insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

Maria Fernanda Prates da Nova 22 February 2008 (has links)
A utilização de grupos de dentes ou de aparelhos dependentes de cooperação, como mecanismos de ancoragem, podem ser fatores limitantes para o sucesso de terapias ortodônticas. Tal fato incentivou a busca de métodos para ancoragem esquelética ou absoluta, que incluem os miniimplantes ortodônticos. Comercialmente estão disponíveis em diversas dimensões e desenhos, porém existem poucas informações sobre a relação de sua morfologia com falhas clínicas ou fraturas. O objetivo deste trabalho foi avaliar o comportamento de miniimplantes com formas diferentes para os seguintes fatores: (a) torque máximo de inserção, (b) torque máximo de remoção, (c) torque de fratura, (d) tipo de fratura, (e) tensão cisalhante e tensão normal. Foram utilizados 20 miniimplantes autoperfurantes, 10 da marca SIN e 10 da Neodent, com 1,6 mm diâmetro e com 8 e 7 mm de comprimento, respectivamente. Destes 10 miniimplantes, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando assim 4 grupos: SIN sem perfil (SSP), SIN com perfil (SCP), Neodent sem perfil (NSP) e Neodent com perfil (NCP). Todos os miniimplantes foram inseridos em cortical de tíbia bovina e depois removidos com micro-motor acoplado a um torquímetro digital que registrou os torques máximos de inserção e de remoção. Os miniimplantes que não fraturaram durante os ensaios de inserção e remoção foram submetidos ao ensaio de fratura realizado em máquina universal de ensaios Emic. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas foram comparados entre todos os grupos. O tipo de fratura foi avaliado pela tensão cisalhante e por avaliação em microscópio eletrônico de varredura (MEV). Para cada grupo comparou-se os torques de inserção e de remoção. Todas as comparações foram feitas através da ANOVA. Verificou-se que o grupo NCP apresentou torque máximo de inserção significativamente maior que os demais grupos (30,6 1,8 Ncm), porém todos fraturaram durante os ensaios de inserção (n=2) ou de remoção (n=3). Não houve diferença significativa entre os grupos para o torque de remoção. Apenas o grupo SSP apresentou diferença significativa entre os torques de inserção e de remoção, para o mesmo grupo. Para o grupo NSP o torque de fratura foi significativamente menor do que todos os outros grupos (27,42 1,14 Ncm). Não houve diferença significativa entre as tensões cisalhante e normal entre os grupos, demonstrando que todos os miniimplantes sofreram fratura do tipo dúctil, confirmado através do MEV. Uma vez que os miniimplantes de todos os grupos são confeccionados com a mesma liga metálica, variando apenas na forma, conclui-se que a resistência à fratura pode ser afetada por esta variável. / The use of groups of teeth or appliances which rely on patient compliance, as anchorage mechanisms, can be limiting factors for the success of orthodontic treatment. This fact encouraged the search for skeletal or absolute anchorage methods, which include orthodontic mini-implants. They are commercially available in different dimensions and designs, but there is scarce information regarding the relation between its morphology and clinical failures or fractures. The purpose of this study was to evaluate the behavior of mini-implants with different forms for the following factors: (a) maximum insertion torque, (b) maximum removal torque, (c) fracture torque, (d) type of fracture, (e) shear tension and (f) normal tension. Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6 mm in diameter and with 8 and 7 mm in length, respectively. Out of these 10 mini-implants, 5 did not have a neck and the other 5 had a 2 mm neck, and were separated into 4 groups: SIN without neck (SSP), SIN with neck (SCP), Neodent without neck (NSP) and Neodent with neck (NCP). All mini-implants were inserted in bovine tibia cortex and later removed with a low speed handpiece connected to a digital torquimeter, which recorded the maximum insertion and removal torques. The mini-implants that did not fracture during insertion and removal assays were submitted to the fracture test, performed in an EMIC universal test machine. The insertion, removal and fracture torques, as well as the calculated shear and normal tensions were compared between all groups. The type of fracture was assessed by the shear tension and by evaluation in scanning electronic microscope (SEM). Insertion and removal torques were compared for each group. All comparisons were done by ANOVA. The NCP group presented a significantly greater insertion torque than all other groups (30.6 1.8 Ncm), but all of them fractured during insertion (n=2) or removal (n=3). There were no significant differences between groups for removal torque. Only group SSP presented a significant difference between insertion and removal torques, for the same group. For group NSP, the fracture torque was significantly smaller than all other groups (27.42 1.14 Ncm). There was no significant difference between shear and normal tensions between groups, demonstrating that all mini-implants suffered ductile fracture, confirmed by SEM. Since mini-implants from all groups are made of the same alloy, varying only in form, one may conclude that resistance to fracture can be affected by this variable.
44

Análise de elementos finitos da distalização do primeiro molar superior com barra transpalatina ancorada em microparafusos ortodônticos

Dobranszki, Adriano 14 November 2014 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-01-29T14:43:44Z No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-10T18:12:36Z (GMT) No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Made available in DSpace on 2015-02-10T18:12:36Z (GMT). No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / O objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de tensões em um primeiro molar superior, após aplicação de força de distalização em uma barra transpalatina (BTP) presa ao molar e ancorada em microparafusos ortodônticos (MPO) instalados em diferentes locais do palato e sugerir a indicação clínica para cada tipo de ativação. Tendo como fonte um banco de dados de tomografias volumétricas, medidas foram feitas e submetidas a análise estatística para criação de um modelo virtual válido de uma maxila humana de um indivíduo portador de relação maxilomandibular de Classe II esquelética típico. Este modelo foi utilizado como base para uma análise combinatória de 3 locais de instalação do MPO (2, 5 e 8 mm) e 3 pontos de ativação na BTP: próximo ao tubo lingual, na metade do comprimento do braço da barra e próximo ao ômega central, resultando em 9 modelos analisados com o programa ANSYS, cada um com aproximadamente 500.000 elementos tetraédricos. Imediatamente após aplicação de carga de 1,5 N na BTP, os valores do deslocamento inicial da trifurcação do molar e da rotação da coroa foram tabulados. Os resultados sugeriram que mudanças na posição de instalação do MPO e do ponto de ativação na BTP produziram diferentes efeitos na movimentação do primeiro molar superior, no sentido A-P, vertical e na rotação (angulação). Com os dados do modelo preliminar, concluiu-se que a maior concentração de tensões na BTP foi localizada na dobra próxima à entrada do tubo lingual, indicando o ponto de maior propensão à falha; no MPO, foi localizada na região do pescoço próximo à transição do perfil transmucoso para as espiras, região em contato com a borda externa do osso cortical palatino, indicando o ponto de maior propensão à falha; no osso cortical palatino, foi localizada na borda externa, mesial ao microparafuso, indicando o ponto em que provavelmente ocorreria maior demanda biológica inflamatória. No modelo definitivo, a ativação “2 mm apical”, próxima ao ômega central da BTP, foi a única que resultou em efeito extrusivo, com deslocamento mesial da coroa e distal das raízes e furca, ativação sugerida para distalização com aumento da dimensão vertical, por extrusão do molar. A ativação “2 mm cervical”, próxima ao tubo lingual do molar, resultou em um efeito leve de intrusão, distalização e acentuado giro distal da coroa, ativação sugerida para distalização quando o molar encontra-se mésioangulado. A ativação “5 mm média”, na metade do comprimento do braço da BTP, resultou em giro distal da coroa e leve movimento intrusivo, ativação sugerida quando o molar encontra-se com leve mesioangulação e ligeiramente extruído, ou quando se deseja distalizar fechando levemente a mordida anterior. A ativação “8 mm médio” produziu pouco efeito de distalização e pouco giro distal da coroa, sugerida quando se deseja pouca distalização com intrusão quase pura do molar, com angulação distal da coroa. A ativação “8 mm apical” produziu muito pouca distalização e acentuada intrusão e angulação distal da coroa, sugerida quando se deseja intruir o molar. ________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate by finite element analysis the stress distribution in a maxillary first molar after application of a distalization force on a transpalatal arch (TPA) attached to the molar and anchored on orthodontic microscrews (OMS) in different locations of the palate and suggest the clinical indication for each type of activation. Having as source a database of volumetric scans, measurements were made and subjected to statistical analysis to create a valid virtual model of a typical skeletal Class II maxillo-mandibular relationship individual. This virtual maxillary model was used as the basis for a combinatorial analysis of 3 OMS installation positions (2, 5 and 8 mm) and 3 TPA activation positions (near the lingual tube, in the half length of the bar arm and near the central omega, resulting in 9 models analyzed using ANSYS program, each with approximately 500.000 tetrahedral elements. Immediately after application of load of 1.5 N in the BTP, the values of the initial displacement of the trifurcation and of the rotation of the molar crown were tabulated. The results suggested that changes in the position of installation and OMS activation point of the TPA produced different effects on the movement of the upper first molar in the A-P and vertical directions and rotation (angle). With the data of the preliminary study it was concluded that the highest stress concentration on the TPA was located at the bend next to the entrance of the lingual tube, indicating the point of higher propensity to failure; on the OMS, it was located at the neck, near to the transition from the transmucosal profile for the thread, site in contact with the external edge of the palatal cortical bone, indicating the point of higher propensity to failure; on the palatal cortical bone, it was located at the external edge, mesial to the OMS, indicating the point where most likely would occur a higher inflammatory biological demand. In the definitive model, the "2 mm apical" activation, next to the central omega of the TPA, was the only activation that resulted in extrusive effect, with mesial displacement of the crown and distal displacement of the roots and of the furcation, suggested activation for distalization with increase of the vertical dimension, by molar extrusion. The "2 mm cervical" activation, next to the molar lingual tube, resulted in a light intrusive effect, distalization and marked crown distal rotation, activation suggested for distalization when the molar is angle to the mesial. The "5 mm activation", at the half of the TPA arm´s lenght, resulted in distal rotation of the crown and light intrusive movement, activation suggested when the molar is slightly angled to the mesial and slightly extruded, or when it is desired to distalize and close the anterior bite slightly. The "8 mm medium" activation produced little effect to the distalization and a slightly distal rotation of the crown, suggested when a slight distalization it is desirable, with almost pure intrusion of the molar with distal angulation of the crown. The "8 mm apical" activation produced very little effect on the distalization and a marked intrusion with distal angulation of the crown, suggested when it is desired to intrude the molar.
45

Avaliação cefalométrica comparativa do tratamento da má oclusão de Classe II com o distalizador first class em ancoragem convencional e esquelética e aparelho extrabucal cervical seguidos de aparelho fixo / Comparative cephalometric evaluation of Class II malocclusion treatment with First Class distalizer in conventional and skeletal anchorage and cervical headgear followed by fixed orthodontic appliance

Roberto Henrique da Costa Grec 06 April 2015 (has links)
O objetivo deste estudo longitudinal foi comparar as alterações dentoesqueléticas e tegumentares de jovens com má oclusão de Classe II não tratados e tratados com distalizador First Class em ancoragem convencional ou esquelética, ou com o aparelho extrabucal cervical (AEB), seguidos do aparelho fixo. A amostra foi composta por 44 pacientes com má oclusão de classe II e divididos em quatro grupos de 11 cada: pacientes tratados com distalizador First Class com ancoragem convencional no botão de Nance (G1), tratados com distalizador First Class com ancoragem esquelética apoiado em 2 mini-implantes no palato (G2), tratados com o aparelho extrabucal (AEB) (G3) e o grupo controle, com pacientes não tratados (G0). Foram obtidas as telerradiografias ao início (Ti) e final (Tf) do tratamento para a realização das análises cefalométricas e avaliação das alterações dentárias, esqueléticas e tegumentares e compará-los com o grupo controle (G0). A análise estatística foi realizada pelo teste t pareado com a finalidade de verificar as alterações ocorridas dentro de um mesmo grupo e pelo teste ANOVA a um critério e teste de Tukey para verificar as diferenças entre os grupos. Observou-se restrição e redirecionamento do crescimento maxilar ao final do tratamento no G1 e G3. Os efeitos esqueléticos na mandíbula só foram significantes no G0. As medidas da relação maxilomandibular diminuíram significantemente no G1 e G3 com significante diminuição das medidas que avaliaram o perfil tegumentar. Quanto ao componente vertical todas as medidas aumentaram no G3. Os primeiros molares superiores angularam distalmente no G2 e os inferiores mesialmente no G3. Os quatro grupos apresentaram extrusão dos dentes superiores e inferiores. Os três grupos experimentais apresentaram diminuição significante nas relações dentárias (relação molar, trespasse horizontal e vertical). Conclui-se que os grupos experimentais corrigiram a má colusão de Classe II de maneira satisfatória, sendo que o uso do AEB mostrou efeitos esqueléticos e dentários na correção e os grupos com distalizadores somente efeitos dentários. O tempo de tratamento no grupo com AEB foi significantemente menor. / The aim of this prospective study was to compare the dental, skeletal and soft tissue changes in youngsters with Class II malocclusion untreated and treated with First Class distalizer in conventional or skeletal achorage or with cervical headgear followed by fixed orthodontic appliances. The sample consisted of 44 patients with Class II malocclusion and divided into four groups of 11: patients treated with First Class distalizer with conventional anchorage (Nance button)(G1), treated with First Class distalizer with skeletal anchorage supported in two palatal mini-implants (G2), treated with cervical headgear (G3) and follow-up group with untreated patients (G0). Lateral cephalometrics radiographs were taken before treatment and after treatment in order to cephalometric analysis and evaluate the dental, skeletal and soft tissue changes and to compare with follow-up group (G0). Statistical analysis was performed by dependent t test to verify the changes occurred in the same group and by one-way ANOVA and Tukey test to verify the changes occurred between the groups. It was observed restriction and redirection of maxillary growth after treatment in G1 and G3. Mandibular skeletal effects were significant in G0. The values of skeletal maxilomandibular relationship decreased significantly in G1 and G3 with significant decrease of measurements that evaluated soft facial profile. All measurements of vertical component increased in G3. Maxillary first molars were distal tipping in G2 and lower first molars were mesial tipping in G3. The four groups showed extrusion in the upper and lower teeth. The three experimental groups showed significant decreased in the molar relationship, overjet and overbite. It concluded that experimental groups corrected the Class II malocclusion efficiently, cervical headgear showed skeletal and dental effects and the groups with distalizers showed only dental effects. The mean treatment period was significant lower with cervical headgear.
46

Avaliação da presença de periodontopatógenos na superfície de miniparafusos ortodônticos por meio microscopia eletrônica de varredura (MEV) e da técnica de reação em cadeia da polimerase (PCR) / Evaluation of periodontopathogen presence on orthodontic mini-screw surfaces by scanning electron microscopy (SEM) and polymerase chain reaction (PCR)

Nacao, Mônica 27 March 2009 (has links)
Os miniparafusos ortodônticos auto-rosqueáveis de liga de titânio têm sido utilizados como recurso de ancoragem durante a movimentação dentária ortodôntica. Estudos têm mostrado uma maior porcentagem de insucesso dos miniparafusos em comparação aos implantes dentários, e a presença de periodontopatógenos tem sido citada na literatura como possível causa da periimplantite. O objetivo deste estudo foi avaliar a presença dos periodontopátogenos na superfície dos miniparafusos por meio da MEV, e identificar, no grupo experimental, as bactérias Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg) e Prevotella intermedia (Pi) pela amplificação do DNA por meio da técnica de PCR. Os miniparafusos do grupo experimental e do grupo controle foram colhidos de pacientes do gênero feminino e masculino, com boa saúde bucal, ausência de doença periodontal, não fumantes e não diabéticos. Os resultados obtidos mostraram, quando analisados pela MEV, a adesão de colônia de bacilos e células inflamatórias na superfície dos miniparafusos no grupo experimental, e adesão de coágulo e malha fibrilar no grupo controle. A técnica PCR revelou 100% de freqüência da Pi em ambos os grupos analisados, a presença de Aa em 31,25% no grupo controle contra 13,3% no grupo experimental e a presença de 37,4%da Pg no grupo controle contra 33,33% no grupo experimental. O teste exato de Fisher não mostrou associação significativa entre a presença e a ausência de Aa (P = 0,39) e Pg (P = 0,70) e os grupos analisados, bem como o OR não revelou associação significativa da Aa (OR = 0,34; IC 95%: 0,05-2,10) e da Pg (OR = 0,61; IC 95%: 0,13- 2,79) com a periimplantite. / Self-tapping titanium alloy orthodontic mini-screws have been used as bony anchorage during orthodontic tooth movement. Studies have shown a higher failure rate of mini-screw than dental implants, and the presence of periodontopathogens has been mentioned in the literature as a possible reason for peri-implantitis. The aim of this study was to evaluate the presence of periodontopathogens on the mini-screw surface by SEM and to identify the bacteria, Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg) and Prevotella intermedia (Pi), by DNA amplification using PCR. Mini-screws of the experimental and control groups were collected from both male and female patients, with good oral health and absence of periodontal disease, non-smoker, and non-diabetic. The results, when analyzed by SEM, showed the adhesion of bacilli and inflammatory cells to the surface of the mini-screws in the experimental group and the adhesion of blood clots and fibril array in the control group. DNA amplification revealed Pi in all cases of both groups analyzed. Aa presence was observed in 31.25% of the control group against 13.3% in the experimental group and Pg presence in 37.4% of the control group against 33.33% in the experimental group. Fishers exact test did not show significant association between both presence and absence of Aa (P = 0.39) and Pg (P = 0.70) and the analyzed groups. Furthermore, odds ratio (OR) revealed no significant association of Aa (OR = 0.34; 95% CI: 0.05-2.10) and Pg (OR = 0.61; 95% CI: 0.13- 2.79) with peri-implantitis.
47

Avaliação do tratamento ortopédico com mini-implantes como ancoragem esquelética em pacientes Classe III com retrusão do terço médio da face / Evaluation of orthopedic treatment using mini-implants as anchorage in Class III patients with retrusion of the middle third of the face

Souza, Ricardo Alves de 27 April 2018 (has links)
O objetivo do trabalho foi avaliar a hipótese nula de que pacientes com maloclusão de Classe III esquelética por deficiência do terço médio da face poderiam ser tratados ortopedicamente utilizando mini-implantes ortodônticos convencionais como apoio de elásticos intermaxilares durante a protração da maxila. No grupo mini-implantes (MI) foram selecionados 12 cranças, nas quais foram instalados dois mini-implantes convencionais na região próxima à mesial das raízes dos primeiros molares permanentes e, outros dois na distal das raízes dos caninos inferiores. Foi orientado que as crianças utilizassem elásticos intermaxilares ¼\" médio, durante 24 horas por dia e força de 200g. No grupo máscara facial (MF) foi realizado o protocolo de expansão rápida da maxila e uso de máscara facial em 13 criancças. Todos os participantes estavam em fase de crescimento, e tinham entre 7 e 12 anos de idade. Através dos dados cefalométricos iniciais e finais dos casos foram realizadas análises estatísticas com Teste t de Student e Mann-Whitney para comparação de amostras independentes, Wilcoxon para amostras pareadas, e nível de significância foi de 5%. Foi possível confirmar que ambos os grupos apresentaram melhora no perfil facial com aumento da convexidade facial e correção da sobressaliência negativa na maioria das crianças, mostrando avanço da maxila, pelas superposições cefalométricas, com diferenças entre T0 e T1 significativas nas medidas SNA, ANB, Wits, Co-A, Co-Gn, NAP, A-Npog, overjet e relação molar, além de Sn-linha H, 1-NB para o grupo MI. Não houve diferença significativa estatisticamente intergrupos nas medidas cefalométricas avaliadas, mas o tempo de tratamento foi significante, sendo mais rápido para o grupo MI. Como conclusão geral, a hipótese nula foi aceita, sendo possível afirmar que mini-implantes convencionais associados a elásticos intermaxilares podem ser uma opção para tratamentos de pacientes Classe III com retrusão maxilar, principalmente em casos de falta de colaboração com o uso da máscara facial, e com reduzido grau de intervenção cirúrgica, que é característica do protocolo de instalação dos mini-implantes. / The aim of this study was to test the null hypothesis that patients with Class III skeletal malocclusion due to deficiency of the middle third of the face could be treated orthopedically with the use of conventional orthodontic mini-implants and support of intermaxillary elastics during protraction of the maxilla. In the mini-implants group (MI) with n = 12, two conventional mini-implants were inserted in the region close to the mesial area of the permanent first molar roots and another two, in the distal area of the mandibular canine roots. The children were instructed to use ¼\" medium intermaxillary elastics, throughout almost 24 hours per day and force of 200g. In the facial mask group (MF) with n = 13, the rapid maxillary expansion protocol and facial mask were performed. All participants were in the growth phase, and were between 7 and 12 years of age. Statistical analyzes were performed using the Student\'s t-test and the Mann-Whitney test for comparison of independent samples, Wilcoxon for paired samples, and a significance level of 5% was used for the initial and final cephalometric data. It was possible to confirm that both groups presented improvement in the facial profile with increase of the facial convexity and correction of the negative overjet in the majority of the children. Advancement of the maxilla was shown by means of cephalometric superimpositions, with significant differences between T0 and T1 in the following measurements: SNA, ANB, Wits, Co-A, Co-Gn, NAP, A-Npog, overjet and molar relationship, in addition to Sn-line H, and 1-NB for Group MI. There was no statistically significant intergroup difference in the cephalometric measurements evaluated, but the time of treatment was significant, as it was faster for Group MI. As a general conclusion, the null hypothesis was acepted, because it was possible to affirm that conventional mini-implants associated with intermaxillary elastics could be an option for the treatment of Class III patients with maxillary retrusion, particularly in cases of lack of cooperation with the use of the face mask. In addition, the degree of surgical intervention was reduced, which is characteristic of the protocol for the insertion of mini-implants.
48

Mini-implantes ortodônticos: avaliação microbiológica e quantificação de endotoxina bacteriana, citocinas pró-inflamatórias e marcadores da osteoclastogênese / Orthodontic mini-implants: microbiological evaluation and quantification of bacterial endotoxin, proinflammatory cytokines and osteoclastogenesis markers

Andrucioli, Marcela Cristina Damião 20 September 2013 (has links)
Os mini-implantes ortodônticos vem sendo amplamente utilizados na prática clínica como dispositivos de ancoragem. No entanto, há casos em que ocorre sua perda durante o tratamento. Inúmeros aspectos tem sido analisados com o intuito de detectar as causas do insucesso, porém estas ainda não estão totalmente esclarecidas. Portanto, utilizando-se dois grupos de mini-implantes - com estabilidade (sucesso) e sem estabilidade (falha) -, os objetivos do presente estudo in vivo foram: 1) avaliar a contaminação microbiana, empregando sondas de DNA para 40 espécies de bactérias, por meio da técnica de biologia molecular checkerboard DNA-DNA hybridization; 2) quantificar a endotoxina bacteriana presente nos mini-implantes dos dois grupos por meio do teste Limulus Amebocyte Lysate ; e 3) quantificar as citocinas pró-inflamatórias IL-1&alpha;, IL-6, IL-17 e TNF-&alpha; e proteínas marcadoras da osteoclastogênese (RANK, RANKL e OPG) por meio da técnica real-time polymerase chain reaction. Dezesseis pacientes de ambos os sexos (11-49 anos) em tratamento ortodôntico com aparelho corretivo e mini-implantes foram selecionados, sendo obtidos 19 miniimplantes com estabilidade e 10 mini-implantes sem estabilidade. O tempo médio de permanência na boca foi de 23,8 meses para os mini-implantes estáveis e 6,7 meses para os mini-implantes sem estabilidade. Foram utilizados mini-implantes da marca Neodent, com 1,6mm de diâmetro e com 7,0 ou 9,0 mm de comprimento, colocados na maxila e/ou mandíbula. Todos os mini-implantes foram instalados e removidos pelo mesmo cirurgião. No momento da remoção, foram coletados os miniimplantes e amostras de gengiva ao redor dos mesmos. Os mini-implantes foram processados para a detecção dos micro-organismos e para a quantificação da endotoxina bacteriana. As amostras de gengiva foram processadas para a quantificação das citocinas pró-inflamatórias e proteínas marcadoras da osteoclastogênese. Os resultados obtidos foram analisados por meio do teste nãoparamétrico de soma de postos de Wilcoxon, considerando-se os conglomerados, utilizando o software SAS. O nível de significância adotado foi de 5%. Todas (100%) as 40 espécies de microorganismos foram observadas em ambos os grupos de mini-implantes, com diferentes porcentagens de ocorrência. Não foi possível observar diferença entre os grupos com relação aos complexos microbianos (azul, roxo, amarelo, verde, laranja, vermelho e outras espécies). Também não foi possível observar diferença na quantificação de endotoxina e das citocinas e marcadores da osteoclastogênese (p>0,05), com exceção da IL-6 (p<0,05). Baseado nos resultados obtidos, pode-se concluir que a contaminação microbiana e a quantidade de endotoxina nos mini-implantes, assim como a expressão das citocinas pró-inflamatórias IL-1&alpha;, IL-17 e TNF-&alpha; e dos marcadores da osteoclastogênese RANK, RANKL e OPG no tecido gengival circundante não atuaram como fatores responsáveis pela perda da estabilidade dos mini-implantes e que a maior expressão da citocina próinflamatória IL-6 pode estar diretamente relacionada à perda da estabilidade dos mini-implantes, sugerindo-se estudos adicionais. / Orthodontic mini-implants have been widely used in clinical practice as anchorage devices. However, their loss may occur during the treatment. Several aspects have been investigated to identify the causes of failure, but they are not yet completely elucidated. Therefore, using two groups of miniimplants - stable and unstable/loose - the objectives of this in vivo study were: 1) to evaluate the microbial contamination, using DNA probes for 40 bacterial species by the checkerboard DNA-DNA hybridization biomolecular technique; 2) to quantify the bacterial endotoxin present in both groups of mini-implants by the Limulus Amebocyte Lysate assay; and 3) to quantify the proinflammatory cytokines IL-1&alpha;, IL-6, IL-17 and TNF-&alpha; and the osteoclastogenesis marker proteins (RANK, RANKL and OPG) by real-time polymerase chain reaction technique. Sixteen patients of both sexes (11 to 49 years old) under orthodontic treatment with corrective appliance and mini-implants were selected, obtaining 19 stable mini-implants and 10 unstable/loose mini-implants. The mean time of permanence in the mouth was 23.8 months for stable mini-implants and 6.7 months for unstable/loose mini-implants. The mini-implants (1.6 mm diameter x 7.0 or 9.0 mm long; Neodent) were placed in the maxilla and/or mandible. All mini-implants were placed and removed by the same surgeon. At the moment of removal, the mini-implants and periimplant gingival tissue samples were collected. The mini-implants were processed for detection of microorganisms and quantification of bacterial endotoxin, while the gingival tissue samples were processed for quantification of proinflammatory cytokines and osteoclastogenesis protein markers. The results were analyzed statistically by the nonparametric Wilcoxon rank-sum test, considering the conglomerates, using SAS software. A significance level of 5% was adopted for all analyses. All (100%) 40 microbial species were observed in both groups of mini-implants, with different percentages of occurrence. No differences could be observed between the groups with respect to the microbial complexes (blue, purple, yellow, green, orange, red and other species). There was no significant difference either in the quantification of endotoxin and cytokines and osteoclastogenesis markers (p>0.05), except for IL- 6 (p<0.05). Based on the obtained results, it may be concluded that neither the microbial contamination and amount of endotoxin in mini-implants, nor the expression of proinflammatory cytokines IL-1&alpha;, IL-17 and TNF-&alpha; and osteoclastogenesis markers RANK, RANKL and OPG in the periimplant gingival tissue acted as factors responsible for the loss of stability of the mini-implants, and that the higher expression of the IL-6 proinflammatory cytokine may be directly associated with the loss of stability of the mini-implants, suggesting additional studies.
49

Distalização da arcada dentária superior ancorada em mini implantes na crista infrazigomática : estudo clínico e análise de elementos finitos /

Ayub, Priscila Vaz January 2019 (has links)
Orientador: Dirceu Barnabé Ravelli / Resumo: Introdução:. A correção da classe II por meio da distalização de toda arcada dentária superior, sem exodontias e ancorada em mini implantes, já foi descrita como relatos de casos isolados. Objetivo: este estudo tem como objetivo avaliar os efeitos da distalização da arcada dentária superior ancorada em mini implante extra alveolar na crista infra zigomática, por meio de análise de elementos finitos (AEF) e clinicamente, meio de tomografia computadorizada de feixe cônico (TCFC), em dois diferentes grupos. Material e Método: Para análise de elementos finitos, foi construído um modelo CAD maxilar, com braquetes em toda a arcada, fio retangular de aço .019x.025” e mini implante na crista infrazigomática, a 10mm do arco de nivelamento. Ganchos estavam localizados entre caninos e primeiro pré-molares em diferentes alturas de 2mm (Grupo1), 10mm (Grupo 2) e 12mm (Grupo 3). Foi aplicada uma força de retração de 2,5N, bilateralmente. Para achados clínicos, dois diferentes grupos foram avaliados. Grupo aparelho autoligado estético (Grupo ALE) foi composto por 15 mini implantes instalados na crista infrazigomática de 10 pacientes (37a03m DP±9.62) que receberam braquetes autoligado estético. Grupo aço inoxidável (Groupo AI) foi composto por 15 mini implantes instalados na crista infrazigomática de 10 pacientes (32a46m DP±16.73) que receberam braquetes metálicos. Tomografia computadorizada de feixe cônico foi realizada antes da instalação dos mini implantes (T1) e após a correção da classe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Skeletal anchorage was also successfully correlated with case reports of maxillary dentition distalization without premolar extraction and with reduced treatment time. Objective: The aim of this study was to evaluated the effects of maxillary dentition distalization with extra-alveolar miniscrews placed in infrazygomatic crest (IZC) area, using finite element method (FEM) and clinically, using cone beam computed tomography (CBCT), comparing two different groups. Methods: For finite element analysis, a maxillary CAD model was constructed with full mouth brackets, a 0.019×0.025-in stainless steel archwire and a miniscrew at infrazygomatic crest, 10mm from the archwire. The power arm was located between canine and first premolar and had different height levels of 2mm (Group 1), 10mm (Group 2) and 12mm (Group 3). A retraction force of 2.5N was applied bilaterally. For clinical responses, two different groups were evaluated. Esthetic self-ligating group (ESL Group) consisted of 15 miniscrews placed in IZC of 10 patients (37y03m DP±9.62) who received esthetic self-ligating brackets. Stainless steel group (SS Group) comprised of 15 miniscrews placed in IZC of 10 patients (32y46m DP±16.73) who received conventional stainless steel brackets. Cone beam computed tomography was made before miniscrew placement (T1) and after class II correction was obtained (T2). Were evaluated treatment time, bracket influence, molar and incisor inclination and distalization, root resorptio... (Complete abstract click electronic access below) / Doutor
50

Mini-implantes ortodônticos: avaliação microbiológica e quantificação de endotoxina bacteriana, citocinas pró-inflamatórias e marcadores da osteoclastogênese / Orthodontic mini-implants: microbiological evaluation and quantification of bacterial endotoxin, proinflammatory cytokines and osteoclastogenesis markers

Marcela Cristina Damião Andrucioli 20 September 2013 (has links)
Os mini-implantes ortodônticos vem sendo amplamente utilizados na prática clínica como dispositivos de ancoragem. No entanto, há casos em que ocorre sua perda durante o tratamento. Inúmeros aspectos tem sido analisados com o intuito de detectar as causas do insucesso, porém estas ainda não estão totalmente esclarecidas. Portanto, utilizando-se dois grupos de mini-implantes - com estabilidade (sucesso) e sem estabilidade (falha) -, os objetivos do presente estudo in vivo foram: 1) avaliar a contaminação microbiana, empregando sondas de DNA para 40 espécies de bactérias, por meio da técnica de biologia molecular checkerboard DNA-DNA hybridization; 2) quantificar a endotoxina bacteriana presente nos mini-implantes dos dois grupos por meio do teste Limulus Amebocyte Lysate ; e 3) quantificar as citocinas pró-inflamatórias IL-1&alpha;, IL-6, IL-17 e TNF-&alpha; e proteínas marcadoras da osteoclastogênese (RANK, RANKL e OPG) por meio da técnica real-time polymerase chain reaction. Dezesseis pacientes de ambos os sexos (11-49 anos) em tratamento ortodôntico com aparelho corretivo e mini-implantes foram selecionados, sendo obtidos 19 miniimplantes com estabilidade e 10 mini-implantes sem estabilidade. O tempo médio de permanência na boca foi de 23,8 meses para os mini-implantes estáveis e 6,7 meses para os mini-implantes sem estabilidade. Foram utilizados mini-implantes da marca Neodent, com 1,6mm de diâmetro e com 7,0 ou 9,0 mm de comprimento, colocados na maxila e/ou mandíbula. Todos os mini-implantes foram instalados e removidos pelo mesmo cirurgião. No momento da remoção, foram coletados os miniimplantes e amostras de gengiva ao redor dos mesmos. Os mini-implantes foram processados para a detecção dos micro-organismos e para a quantificação da endotoxina bacteriana. As amostras de gengiva foram processadas para a quantificação das citocinas pró-inflamatórias e proteínas marcadoras da osteoclastogênese. Os resultados obtidos foram analisados por meio do teste nãoparamétrico de soma de postos de Wilcoxon, considerando-se os conglomerados, utilizando o software SAS. O nível de significância adotado foi de 5%. Todas (100%) as 40 espécies de microorganismos foram observadas em ambos os grupos de mini-implantes, com diferentes porcentagens de ocorrência. Não foi possível observar diferença entre os grupos com relação aos complexos microbianos (azul, roxo, amarelo, verde, laranja, vermelho e outras espécies). Também não foi possível observar diferença na quantificação de endotoxina e das citocinas e marcadores da osteoclastogênese (p>0,05), com exceção da IL-6 (p<0,05). Baseado nos resultados obtidos, pode-se concluir que a contaminação microbiana e a quantidade de endotoxina nos mini-implantes, assim como a expressão das citocinas pró-inflamatórias IL-1&alpha;, IL-17 e TNF-&alpha; e dos marcadores da osteoclastogênese RANK, RANKL e OPG no tecido gengival circundante não atuaram como fatores responsáveis pela perda da estabilidade dos mini-implantes e que a maior expressão da citocina próinflamatória IL-6 pode estar diretamente relacionada à perda da estabilidade dos mini-implantes, sugerindo-se estudos adicionais. / Orthodontic mini-implants have been widely used in clinical practice as anchorage devices. However, their loss may occur during the treatment. Several aspects have been investigated to identify the causes of failure, but they are not yet completely elucidated. Therefore, using two groups of miniimplants - stable and unstable/loose - the objectives of this in vivo study were: 1) to evaluate the microbial contamination, using DNA probes for 40 bacterial species by the checkerboard DNA-DNA hybridization biomolecular technique; 2) to quantify the bacterial endotoxin present in both groups of mini-implants by the Limulus Amebocyte Lysate assay; and 3) to quantify the proinflammatory cytokines IL-1&alpha;, IL-6, IL-17 and TNF-&alpha; and the osteoclastogenesis marker proteins (RANK, RANKL and OPG) by real-time polymerase chain reaction technique. Sixteen patients of both sexes (11 to 49 years old) under orthodontic treatment with corrective appliance and mini-implants were selected, obtaining 19 stable mini-implants and 10 unstable/loose mini-implants. The mean time of permanence in the mouth was 23.8 months for stable mini-implants and 6.7 months for unstable/loose mini-implants. The mini-implants (1.6 mm diameter x 7.0 or 9.0 mm long; Neodent) were placed in the maxilla and/or mandible. All mini-implants were placed and removed by the same surgeon. At the moment of removal, the mini-implants and periimplant gingival tissue samples were collected. The mini-implants were processed for detection of microorganisms and quantification of bacterial endotoxin, while the gingival tissue samples were processed for quantification of proinflammatory cytokines and osteoclastogenesis protein markers. The results were analyzed statistically by the nonparametric Wilcoxon rank-sum test, considering the conglomerates, using SAS software. A significance level of 5% was adopted for all analyses. All (100%) 40 microbial species were observed in both groups of mini-implants, with different percentages of occurrence. No differences could be observed between the groups with respect to the microbial complexes (blue, purple, yellow, green, orange, red and other species). There was no significant difference either in the quantification of endotoxin and cytokines and osteoclastogenesis markers (p>0.05), except for IL- 6 (p<0.05). Based on the obtained results, it may be concluded that neither the microbial contamination and amount of endotoxin in mini-implants, nor the expression of proinflammatory cytokines IL-1&alpha;, IL-17 and TNF-&alpha; and osteoclastogenesis markers RANK, RANKL and OPG in the periimplant gingival tissue acted as factors responsible for the loss of stability of the mini-implants, and that the higher expression of the IL-6 proinflammatory cytokine may be directly associated with the loss of stability of the mini-implants, suggesting additional studies.