• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 20
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 101
  • 101
  • 35
  • 32
  • 26
  • 24
  • 21
  • 21
  • 21
  • 19
  • 14
  • 10
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

The Salt Lake Tabernacle : acoustic characterization and study of spatial variation /

Rollins, Sarah, January 2005 (has links) (PDF)
Thesis (M.S.)--Brigham Young University. Dept. of Physics and Astronomy, 2005. / Includes bibliographical references (p. 115-120).
32

Προσομοίωση και ανάλυση της ακουστικής χώρων της αρχαιότητας

Βασιλαντωνόπουλος, Σταμάτης 22 June 2010 (has links)
- / -
33

Diagnóstico das características acústicas de seis igrejas católicas de Campinas / Acoustical assessment of six catholic churches in Campinas

Smiderle, Roberta, 1985- 22 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-22T04:56:34Z (GMT). No. of bitstreams: 1 Smiderle_Roberta_M.pdf: 26489976 bytes, checksum: 44609708b319cf198f5a0772379f7c32 (MD5) Previous issue date: 2013 / Resumo: A inteligibilidade acústica se faz necessária para várias finalidades em diferentes tipos de ambientes. Dentre esses ambientes as igrejas católicas são locais com ampla variedade de atividades relacionadas à fala e música que requerem inteligibilidade acústica adequada. O comportamento acústico de igrejas é um tema que vem sendo estudado há algum tempo devido ao fato de serem ambientes que agregam diferentes tipos de eventos, missa, culto, palestras, concertos e outras atividades relacionadas ou não à religião, exigindo estudos que levem em conta essa flexibilidade. Ao longo da História do catolicismo, a Igreja, como instituição, passou por diversas mudanças que modificaram o modo como à celebração deveria ser conduzida e também os tipos de atividades, alterando o desempenho acústico requerido nos edifícios. Baseado nessas premissas verifica-se que a qualidade acústica de tais ambientes é de complexa variabilidade. Nesta dissertação foram avaliadas acusticamente seis igrejas católicas na cidade de Campinas, a Basílica Nossa Senhora do Carmo, Catedral Metropolitana de Campinas Nossa Senhora da Imaculada Conceição, Igreja de Sant'Ana, Igreja de Nossa Senhora das Dores, Igreja de Santa Rita de Cássia e Igreja de São Paulo Apóstolo. As igrejas avaliadas não foram escolhidas aleatoriamente, mas escolhidas em relação ao período de construção e a tipologia arquitetônica de cada uma das igrejas. O objetivo desta pesquisa foi avaliar o desempenho acústico das igrejas considerando as diversas combinações de fontes e receptores sonoros que podem ocorrer no interior da edificação, e buscar relacionar o desempenho acústico com suas características arquitetônicas. A avaliação acústica das igrejas foi feita por meio da análise dos resultados da medição dos parâmetros acústicos Tempo de Reverberação (TR), Tempo de Decaimento Inicial (EDT), Clareza (C80), Definição (D50) e Índice de Transmissão da Fala (STI). Os procedimentos das medições acústicas foram feitas baseadas na norma ISO 3382-1:2009, considerando que os edifícios podem ser considerados como ambientes de performance de acordo com a tipologia e uso, garantindo que os dados obtidos sejam passíveis a comparações em análises com outros estudos. Os resultados obtidos foram analisados de acordo com padrões propostos na literatura para avaliação de desempenho acústico qualificando o comportamento acústico das igrejas para as atividades desenvolvidas em cada uma delas. Tais resultados demonstraram, em grande maioria, que as igrejas estudadas apresentam parâmetros acústicos de valores inadequados para as atividades desenvolvidas hoje em dia. No entanto, têm-se também em alguns casos, parâmetros adequados a situações específicas, como na Catedral, onde a fonte de orquestra, posicionada sob a cúpula apresenta excelentes valores de Clareza, qualidade de valores também alcançados pelas igrejas de São Paulo Apóstolo e Sant'Ana em posições de coro original. Muito dos reposicionamentos de fonte sonora ocorridos no interior das igrejas, de acordo com as novas atividades, apresentou valores inferiores aos medidos em posição original, como se pode perceber na igreja de Nossa Senhora das Dores e na Basílica do Carmo, nas quais as novas posições de coro têm parâmetros acústicos com valores inferiores aos adequados à Clareza. Este estudo trouxe como contribuição o levantamento das características acústicas dessas igrejas, tornando possível a análise e comparação dos dados obtidos com relação a trabalhos posteriores. Sendo possível analisar não apenas os valores para os parâmetros acústicos avaliados, mas também como as características da arquitetura de cada edificação fizeram com que o comportamento acústico se desenvolvesse de tal modo no interior das igrejas / Abstract: Acoustic Intelligibility is one of the great important subjects for the performance of many environments such as catholic churches. Such places are used for many types of performances requiring adequate intelligibility for speech and clarity for music. The acoustic performance of worship places has been studied for a while because such places can accommodate not only religious events but also different kinds of events related or not to religion. Along Catholicism history, the church as an institution has been changing over the years the procedure of its rituals such as the mass and opening their temples to other kinds of performances making the acoustic performance of such environments require great deal of complexity. This research analyzed six catholic churches in the city of Campinas, Sao Paulo, Brazil. Churches were chosen according its period of construction and architectural typology. The objective of this research is to study the acoustic performance of these churches and establish a relationship with the architectural characteristics of the temple. Measurement of acoustic parameters such as Reverberation Time (RT), Early Decay Time (EDT), Clarity Index (C80), Definition (D50) and Speech Transmission Index (STI) were used to analyze the acoustic performance of the churches. Measurements were done according to ISO 3382-1:2009. Churches can be considered performance spaces due to its broader possibilities of use, making it possible to compare its data with other similar researches. Results were also analyzed according to procedures specifically proposed for those spaces found in the literature making it possible to qualify the acoustic behavior of churches for each specific use and allowing further studies and comparisons / Mestrado / Arquitetura e Construção / Mestra em Engenharia Civil
34

Study on improvement of sound insulation performance for multi-layer windowpanes and gaps. / 多重窓及び隙間における遮音性能改善に関する研究

Shimizu, Takafumi 23 March 2016 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(工学) / 乙第13010号 / 論工博第4135号 / 新制||工||1649(附属図書館) / 32938 / 京都大学大学院工学研究科都市環境工学専攻 / (主査)教授 髙橋 大弐, 教授 鉾井 修一, 教授 竹脇 出 / 学位規則第4条第2項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DGAM
35

Architectural acoustics in broadcasting

Legault, Jean Pierre Camille. January 1975 (has links)
No description available.
36

An Acoustical Analysis of Domes Coupled to Rooms, with Special Application to the Darussholah Mosque, in East Java, Indonesia

Utami, Sentagi Sesotya 12 August 2005 (has links) (PDF)
Concave surfaces are often considered to be detrimental or precarious in room acoustics, especially because of the impact they have on the distribution of sound energy. However, it is often difficult to avoid such surfaces in buildings with specific architectural functions. A primary example of this involves mosques, which are sacred places of worship for Muslims. In keeping with the Islamic architectural style, most mosques incorporate a symbolic centralized domed ceiling as part of their room structures. These domes are open on the bottom and coupled to the acoustic spaces below. In many cases, the lower spaces may be idealized rectangular enclosures. Owing to the distinctness and ubiquity of this basic architectural form, a thorough, fundamental analysis of such environments would be useful to the architectural acoustics community. In this study, predictions from EASE (trademark) computer models were compared to the results derived from physical scale model measurements. The scale model measurement techniques involved evaluation of impulse responses in a 1:12 scale model of Darussholah mosque, in East Java, Indonesia. A miniature human voice source was created to carry out the impulse response measurements. It was carefully evaluated to ensure that it produced adequate frequency response and directivity comparable to an actual human voice. Acoustical parameters were derived from the impulse responses. Statistical analysis using ANOVA and t-tests were used to compare results from the measurements with variations of domed ceiling configurations and other aspects of the measurement setting. Conclusions were based on these comparisons and on auralization listening tests in order to ascertain the elements that produced the most significant impact on the mosque acoustics. The analysis helps establish criteria for good acoustics in mosques and other buildings with domed ceilings.
37

Implementation of Microphone Array Processing Techniques on A Synthetic Array for Fluid Power Noise Diagnostics

Dan Ding (6417068) 10 June 2019 (has links)
<div>Fluid power is widely used in a variety of applications such as construction machines, aerospace, automotive, agricultural machinery, manufacturing, etc. Although this technology has many obvious advantages such as compactness, robustness, high power density, and so forth, there is much room for improvement, of which one of the most important and challenging problems is the noise.</div><div><br></div><div>Different institutes have been researching fluid power noise for decades. However, much of the experimental investigation was based on simple measurement and analysis techniques, which left the designers/researchers no method of understanding the complicated phenomena. A microphone array is a powerful tool that unfortunately has not been introduced to the fluid power noise research. By capturing the magnitude and phase information in space, a microphone array enables the noise source identification, separation, localization and so forth.</div><div><br></div><div>This thesis focuses on implementing the microphone array processing techniques on a synthetic microphone array for fluid power noise diagnostics. Differing from traditional scan-based approaches, the synthetic array is created by synchronizing the non-synchronous measurements to achieve the equivalent effect of a multi-microphone snapshot. The final results will show the power of microphone arrays and provide an economical solution to achieve approximate results when a real microphone array is not available.</div>
38

Determinação de faixas de operação de parâmetros acústicos para avaliação da qualidade sonora de salas de aula. / Determination of operating ranges of acoustic parameters for evaluation of the sound quality of classrooms.

Cristina Yukari Kawakita Ikeda 10 December 2018 (has links)
Boas condições acústicas, para a transmissão e para o entendimento da mensagem falada, são importantes para a eficácia do processo de aprendizagem. Para tanto, além de se minimizar a intrusão do ruído externo, é fundamental que a distribuição da energia sonora no interior das salas de aula seja adequada. Quando não se adotavam soluções prescritivas, utilizava-se para projeto, apenas, o tradicional tempo de reverberação. Na literatura, há faixas de valores para outros descritores que, por falta de estudos específicos, não são empregados para salas de aula. Esta pesquisa enfoca essa lacuna no conhecimento, ou seja, estabelecimento de faixas adequadas de outros descritores que possam ser empregados na otimização do projeto acústico de salas de aula sob a perspectiva dos alunos. Para atingir esse objetivo utilizou-se de métodos de Avaliação Pós-Ocupação, com a aplicação de questionários e a medição de descritores, usando-se a técnica de medição da resposta impulsiva, de várias salas de escolas diferentes, a fim de associar os valores medidos com o grau de satisfação expressado pelos usuários dos espaços. As medições foram feitas, em oitavas, ao longo de uma malha de pontos. Os valores medidos foram complementados com simulações computacionais para avaliar outras posições no interior dos recintos. Foram analisados os descritores TR, EDT, BR, Ts, D50 e RASTI. Destes parâmetros, foram selecionados aqueles que podem ser otimizados pelas decisões de projeto arquitetônico, sendo estes: TR, EDT, Ts e RASTI. / Good acoustic conditions, for the transmission and understanding of the spoken message, are important for the effectiveness of the learning process. Therefore, in addition to minimizing the intrusion of outdoor noise, it is essential that the distribution of the sound energy inside the classrooms is adequate. When prescriptive solutions were not adopted, only the traditional reverberation time was used for design. In the literature, there are ranges of values for other descriptors that, for lack of specific studies, are not used for classrooms. This research focuses on this knowledge gap, that is, the establishment of adequate ranges of other descriptors that can be used to optimize the acoustic design of classrooms from the perspective of the students. In order to accomplish this objective, Post-Occupancy Evaluation methods were used, with the application of questionnaires and the measurement of descriptors, using the impulse response measurement technique of several classrooms from different schools, in order to associate the measured values with the degree of satisfaction expressed by its users. Measurements were made in octave bands along a mesh of points. The obtained values were complemented with computational simulations to evaluate other positions inside the rooms. The descriptors TR, EDT, BR, Ts, D50 and RASTI were analyzed. From these parameters, those that can be optimized by the architectural design decisions were selected, being these: TR, EDT, Ts and RASTI
39

Soundscape of urban open spaces in Hong Kong. / CUHK electronic theses & dissertations collection

January 2011 (has links)
Lin, Hui. / "November 2010"--Abstract. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2011. / Includes bibliographical references (leaves 172-179). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
40

Reconstrução acústica das salas de cinema projetadas pelo arquiteto Rino Levi / Acoustic Reconstruction of the movie theatres designed by the architect Rino Levi

Carlos Augusto de Melo Tamanini 12 April 2011 (has links)
Este estudo visou realizar um resgate histórico e, através do método de modelagem acústica, reconstruir acusticamente as salas de cinema projetadas pelo arquiteto Rino Levi. Utilizando dados mensuráveis e relatos publicados por Rino e outros autores, modelos foram criados. A partir dos modelos, realizaram-se comparações e avaliações dos parâmetros acústicos e das respostas, obtidas através de mapas acústicos gerados por simulações, para verificar as técnicas e soluções empregadas pelo arquiteto. Comprovou-se que a metodologia desenvolvida pelo arquiteto para a realização do tratamento acústico da sala do cinema é pertinente e inovadora para a época, entretanto algumas técnicas e soluções, em função dos resultados apresentados, passam a ser questionadas. O Cine Ufa-Palácio, o primeiro cinema a ser projetado por Levi, apresentou o melhor desempenho acústico em função de soluções empregadas somente no seu projeto. Nos outros projetos, principalmente no Cine Universo e Piratininga, notou-se, através do desempenho acústico, que algumas soluções contribuíram para um resultado pouco satisfatório. A importância de Levi para a acústica no Brasil é incontestável, mas suas soluções, até divulgadas como muito eficientes, devem ser repensadas e tratadas com critérios para a correção de possíveis falhas. Finalmente, o contato com essas salas de cinema projetadas por Levi foi significativo, independente dos resultados, por constatar a sua visão sobre arquitetura, baseada na técnica e nos princípios científicos, enfatizando um raciocínio projetual que revela a clareza de sua arquitetura. / A historical virtual acoustical reconstruction was developed in five movie theaters designed by the architect Rino Levi from 1936 to 1941, in the cities of São Paulo and Recife, by means of computer simulations. Such approach was chosen because these movie theatres have been demised or are now used with different purposes. Rino Levi is recognized as one of the Brazilian greatest architects, and the present work shows that he was perhaps the first to introduce the scientific results of Sabine in the design of acoustical sensitive rooms. By means of the original drawings and reports published by Rino Levi and others, geometric models have been created to carry out the computer simulations. From these models, Reverberation Times and Early Decay Times were obtained, and maps of speech intelligibility parameters such as C50 and RaSTI throughout the audiences have been generated. These allowed the evaluation of the acoustical results that would have been achieved by Rino Levi in these cinemas. Although the approaches employed by Rino Levi was considered innovative at that time, it is shown that some of his solutions, particularly those related to the shapes of the internal surfaces and structures, may be questioned by the present day knowledge. It is shown that Cine-Ufa Palace, the first movie theater designed by Rino Levi, supposedly presented the best acoustic performance among the movie theatres that have been simulated, whereas the adopted solutions to other cinemas, such as Cine Universe and Cine Piratininga, may have contributed to unsatisfactory acoustical results. Finally, regardless of the criticisms that can now be made to his approaches in the acoustical design of rooms, the acoustical reconstruction of the movie theaters designed by Rino Levi was significant, because it has been possible to get acquainted with his views of architecture, which had been based on technical and scientific principles, emphasizing a project reasoning that reveals the clarity of his solutions.

Page generated in 0.0997 seconds