Spelling suggestions: "subject:"coverage bubble diameter"" "subject:"beverage bubble diameter""
1 |
Avaliação das condições hidrodinâmicas, de transferência de oxigênio e de cisalhamento em diferentes modelos e escalas de reatores pneumáticos / Evaluation of hydrodynamic, oxygen transfer and shear conditions in different models and scales of pneumatic reactorsMendes, Caroline Eliza 26 April 2016 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-10-05T19:18:20Z
No. of bitstreams: 1
TeseCEMac.pdf: 12049463 bytes, checksum: acd65707762e60b912f35a2d267ad5b7 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-20T13:40:54Z (GMT) No. of bitstreams: 1
TeseCEMac.pdf: 12049463 bytes, checksum: acd65707762e60b912f35a2d267ad5b7 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-20T13:41:14Z (GMT) No. of bitstreams: 1
TeseCEMac.pdf: 12049463 bytes, checksum: acd65707762e60b912f35a2d267ad5b7 (MD5) / Made available in DSpace on 2016-10-20T13:41:32Z (GMT). No. of bitstreams: 1
TeseCEMac.pdf: 12049463 bytes, checksum: acd65707762e60b912f35a2d267ad5b7 (MD5)
Previous issue date: 2016-04-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Due to the high capacity of oxygen transfer and versatility, pneumatic reactors have been
constantly used in bioprocesses. However, aiming to expand the use of these bioreactors in the industry, as well as increase the understanding of the complex phenomena that occur in these devices, this thesis aimed to evaluate the hydrodynamic, oxygen transfer and shear conditions in three models of pneumatic reactors (bubble column, concentric-tube airlift and split-cylinder airlift) in the scales of 5 and 10 L, using as liquid phase four Newtonian fluids and eight non-Newtonian fluids, and five specific air flow rate (air of 1 to 5 vvm). Related to the
hydrodynamic were studied the global gas hold-up (g), the gas hold-ups in the riser (R) and
in the downcomer (D), liquid circulation time (tC), superficial liquid velocity in the riser (ULR)
and in the downcomer (ULD), and the percentage energy losses in the riser (%ER+%EFR), in the
downcomer (%ED+%EFD), and in the bottom (%EB) of airlift reactors. The values of g, R, D, ULR and ULD showed increasing behaviour with increase of air and decreasing behaviour with the kinematic liquid viscosity (L) and the rheologic properties (K e n), and observed the
opposite for tC. The higher values of g, R, D and tC were obtained for concentric-tube airlift
reactor (ACC) and scale of 10 L. With exception of ULR of Newtonian fluids, the others liquid
velocity tests resulted in higher values for split-cylinder airlift reactors (ASC) and scale of 10
L. This result was attributed to the greater driving force (R-D) to liquid circulation obtained in
the ASC reactors and the higher energy losses in the riser and in the downcomer observed in
the ACC reactors. In the bottom of the airlift reactors, the higher values of %EB were obtained
to the ASC reactor. To evaluate the mass transfer were studied, the average bubble diameter
(Db), the volumetric oxygen transfer coefficient (kLa) and the terms that compose the kLa, the
convective mass transfer coefficient (kL) and the specific interfacial area of mass transfer (aL).
With the increase of air, L, K and n, the air bubbles were predominantly coalescent in water,
presenting distorted shape, and non-coalescent with spherical/elliptical shape in the other
solutions. It was observed a similar behavior between the kLa and aL parameters, which were
directly proportional to the air and inversely proportional to the L, K and n. In water, the aL
values were lower than glycerol solutions due to the higher Db values observed in this liquid.
For the kL, it was observed a decreasing behaviour with the increase of the air in the most solutions. The magnitude of kL values was due mainly the oxygen difusivity in the liquid, and
the higher values were observed to the water, following by the non-Newtonian solutions. In
general, the higher values of the mass transfer parameters were obtained in the ACC reactor
and in the scale of 10 L. The proposed method to the estimate the average shear rate velocity
based on Kolmogorov’s theory of isotropic turbulence showed results consistent with the
literature relative to the behavior and magnitude of this variable, as well as the results obtained
by the analysis of the morphological changes of Streptomyces clavuligerus in two models of
airlift reactors and two aeration conditions. Were proposed correlations to predict all evaluated
parameters. Were obtained in all cases a good fit with the experimental data, with deviations
between the calculated and experimental values below 20%. / Devido à alta capacidade de transferência de oxigênio e versatilidade, reatores pneumáticos têm sido constantemente utilizados em bioprocessos. Entretanto, visando ampliar a utilização destes reatores na indústria, assim como aumentar a compreensão dos fenômenos complexos que ocorrem nestes dispositivos, na presente tese teve-se como objetivo avaliar as condições hidrodinâmicas, de transferência de oxigênio e de cisalhamento em três modelos de reatores pneumáticos (coluna de bolhas, airlift de cilindros concêntricos e airlift split-cylinder) nas
escalas de 5 e 10 L, utilizando como fase líquida quatro fluidos newtonianos e oito fluidos nãonewtonianos e cinco vazões específicas de ar (ar de 1 a 5vvm). Em termos hidrodinâmicos
foram estudadas as retenções gasosas global (g), no riser (R) e no downcomer (D), tempo de circulação do líquido (tC), velocidade superficial do líquido no riser (ULR) e no downcomer (ULD) e as perdas percentuais de energia no riser, no downcomer e na base (%EB) de reatores airlift. Os valores de g, R, D, ULR e ULD apresentaram comportamento crescente com o aumento de ar e decrescente com a viscosidade cinemática do líquido (L) e propriedades reológicas (K e n), sendo observado o oposto para tC. Os maiores valores de g, R, D e tC foram obtidos em reator airlift de cilindros concêntricos (ACC) e escala de 10 L. Com exceção de ULR de fluidos newtonianos, os demais testes de velocidade do líquido resultaram em maiores valores nos reatores airlift split-cylinder (ASC) e escala de 10 L. Tal resultado foi atribuído a maior força motriz (R-D) para circulação do líquido obtida em ASC e às maiores perdas de energia no riser e no downcomer observadas em reatores ACC. Na base dos reatores, os maiores valores de %EB foram obtidos para reator ASC. Para avaliação da transferência de massa foram estudados o diâmetro da bolha (Db), o coeficiente volumétrico de transferência de oxigênio (kLa) e os termos que o compõe, coeficiente convectivo de transferência de massa (kL) e área interfacial específica de transferência de massa (aL). Bolhas de ar, com o aumento de ar, L, K
e n foram predominantemente coalescentes em água, apresentando formato distorcido e nãocoalescentes com formato esférico/elíptico nas demais soluções. Observou-se um
comportamento análogo entre kLa e aL, com relação direta à ar e inversa à L, K e n. Em água, os valores de aL foram inferiores às soluções de glicerol em virtude do maior Db observado neste líquido. Para kL, observou-se um comportamento decrescente com o aumento de ar na maioria das soluções. A magnitude dos valores de kL obedeceu principalmente a difusividade do oxigênio no líquido, sendo os maiores valores observados para água, seguido das soluções não-newtonianas. De maneira geral, os maiores valores dos parâmetros de transferência de massa foram obtidos em reator ACC de 10 L. O método proposto para estimativa da taxa de cisalhamento com base na teoria de turbulência isotrópica de Kolmogorov apresentou
resultados condizentes com a literatura em termos de comportamento e magnitude desta
variável, assim como com os resultados obtidos pela análise das alterações morfológicas de
Streptomyces clavuligerus em dois modelos de reatores airlift e duas condições de aeração. Para todos os parâmetros avaliados foram propostas correlações para sua predição, sendo obtidos em todos os casos bons ajustes aos dados experimentais com desvios inferiores à 20%. Palavras-chave: reatores pneumáticos, retenção gasosa, kLa, diâmetro da bolha, velocidade
|
Page generated in 0.0719 seconds