• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 47
  • 47
  • 25
  • 23
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação in vitro da capacidade de vedamento bacteriano da interface implante e componente protético em sistema cone Morse em função de alterações estruturais e uso de selantes industriais / In vitro evaluation of the sealing ability of bacterial interface implant and prosthetic component in Morse taper system due to structural changes and the use of industrial sealants

Antonio da Silva Ramos Neto 13 November 2013 (has links)
O objetivo deste estudo foi comparar, in vitro, os sistemas de implante cone Morse, frente ao vedamento contra a penetração bacteriana entre o implante e o componente protético, em função de alterações estruturais e uso de selantes industriais. Foram utilizados 126 implantes Titamax CM EX distribuídos em três tipos de componentes protéticos: Munhão Universal CM, Munhão Universal CM com Parafuso Passante e Munhão Universal CM Exact, todos da empresa Neodent (Curitiba, Paraná, Brasil). Estes implantes foram divididos em 3 grupos de 42 implantes componentes protéticos, sendo os grupos devidamente denominados: Grupo 1 (G1) - Controle, Grupo 2 (G2) - Jateamento e Grupo 3 (G3) - Adesivo. Estes implantes, devidamente distribuídos entre os componentes protéticos e seus grupos, foram avaliados quanto à contaminação bacteriana em um período de 28 dias após o término da experimentação inicial em que foi realizado o efeito de ciclagem sobre as amostras (sem e com carga). Os implantes foram perfurados em sua porção apical com uma fresa de 1mm de diâmetro, até o encontro de sua câmara interna. Foram instalados os componentes protéticos de titânio em cada grupo com torque recomendado pelo fabricante (32 e 15 N.cm). Antes os componentes dos grupos G2 e G3 passaram por alterações estruturais (jateamento e adesivo Dermabond® respectivamente). As peças foram anexadas a tampas de tubo de ensaio, com a porção do componente voltada para o interior do tubo. Os tubos de ensaio foram preenchidos com meio de cultura líquido LB, utilizando-se seringa estéril. Todos os conjuntos receberam esterilização por radiação Gama (Embrarad, Campinas, Brasil). Após a confirmação da efetividade da esterilização por meio de amostras controle, os orifícios apicais foram cuidadosamente desobstruídos e inoculados com cultura de E. coli. O controle de turvamento das amostras foi realizado diariamente, os resultados apontaram que três das amostras do G1, sete do G2 e duas do G3, que não foram submetidas a ciclagem, sofreram contaminação num período de até 28 dias, e que três amostras do G1, dez do G2 e nenhuma do G3, quando submetidas ao efeito da ciclagem, foram contaminaram. Todos os grupos apresentaram infiltração bacteriana, independentemente do componente protético e da ciclagem. Ficou evidenciado que o grupo jateamento apresentou os piores resultados e que o adesivo apenas reduziu, mas não impediu a infiltração bacteriana para o interior dos implantes cone Morse. / The aim of this study was to compare, in vitro, Morse taper implant systems sealing against bacterial penetration between implant and prosthetic component after modifying the abutment structure or using industrial strength sealants. 126 Titamax CM EX implants and three different types of prosthetic components were used: Universal Post CM, CM Universal Post with passing screw and Universal Post CM Exact (Neodent implants, Curitiba, Parana, Brazil). These samples were divided into three groups: Group 1 Control group (G1); Group 2 Sandblasting (G2); and Group 3 Adhesive (G3). The implant / prosthetic component bacterial leakage from each group was evaluated after 28 days with or without cyclic loading. A hole at the apical portion of the implant was done with a 1 mm bur to access the implant internal threads. The abutments were inserted and torqued according to the manufacturer recommendation (15 or 32 N.cm). G2 abutments were sandblasted before insertion. G3 abutments were sealed with Dermabond® adhesive. The samples were sterilized by Gamma irradiation (Embrarad, Campinas, Brazil) and attached to the test tube lid and placed in the test tube filled with bacterial growth media (LB). Control samples from each group were used to assess bacterial contamination before starting the experiment. The access holes at the apical part of the implants were accessed and an E. coli culture was inoculated inside the implant internal threads and then sealed again. Changes in the media color (turbidity), indicative of bacterial leakage from inside the implant to the media were evaluated daily. Three samples from G1, seven from G2 and two from G3 without cyclic loading showed bacterial leakage after 28 days. Three samples from G1, ten from G2 and none of the samples from G3 showed bacterial leakage in the cyclic loading condition. All groups demonstrated bacterial leakage disregard of the type of abutment and loading conditions. It was demonstrated that G2 (sandblasted surface) had the worst results. Use of industrial sealant reduced but did not completely prevented bacterial leakage in Morse taper implants.
12

The effect of two tube-feeding protocols on bacterial contamination and diarrhea in ICU patients

Davidson, Lynda J. January 1995 (has links)
No description available.
13

Qualidade microbiológica de águas minerais em garrafas individuais comercializadas em Araraquara /

Dias, Maria Fernanda Falcone. January 2008 (has links)
Orientador: Adalberto Farache Filho / Banca: Maria da Penha Longo Mortatti Catanozi / Banca: Wellington Cyro de Almeida Leite / Resumo: Com a dúvida sobre a qualidade da água de abastecimento público, o cidadão passou a utilizar a água mineral com maior intensidade. Para atender a esta demanda as indústrias aumentaram a produção, novas empresas surgiram e também os falsários. Assim, é necessário conhecer-se a qualidade esperada e paga pelo consumidor nesse produto, realmente existe. O objetivo desta pesquisa foi avaliar aspectos de qualidade microbiológica em amostras de água mineral natural, não carbonatada, em garrafas individuais de 330mL a 600mL, das diversas marcas comercializadas em supermercados na cidade de Araraquara-SP. Foram utilizadas sessenta e nove amostras provenientes de dezessete marcas. As amostras foram adquiridas aleatoriamente, em épocas e estabelecimentos diferentes para que fossem originadas de lotes diversos. Para análise de coliformes totais e coliformes fecais/E. coli utilizou-se a técnica de substratos cromogênicos; para enterococos e Pseudomonas aeruginosa foram utilizadas as técnicas de tubos múltiplos específicas; para contagem de bactérias heterotróficas, foi utilizada a técnica de cultivo em profundidade. Todas as amostras de todas as marcas (100%) apresentaram ausência de coliformes fecais/E.coli, duas amostras (2,9%) de uma marca (5,9%) apresentaram contaminação por coliformes totais, duas amostras (2,9%), de duas marcas (11,8%) apresentaram contaminação por enterococos, três amostras (4,3%) de duas marcas (11,8%) apresentaram Pseudomonas aeruginosa e quarenta amostras (58%) de doze marcas (70,6%) apresentaram contagens acima de 500 UFC/mL para bactérias heterotróficas. Verificou-se que, das sessenta e nove amostras analisadas (100%) apenas seis (8,7%) apresentaram-se contaminadas com um ou mais dos indicadores especificados pela legislação brasileira para águas minerais. Entretanto, considerando os padrões para água mineral e o padrão...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With the doubt on the water quality in public supplying, the citizen started to use the mineral water with larger intensity. For attend this demand the factory had increased the production, new companies had appeared and also the falsifiers. Thus, it's necessary to know if the quality waited and paid for the consumer in this product, really exists. The objective of the research was to evaluate aspects of microbiological quality in natural mineral water samples, not carbonated, in individual bottles of 330mL to 600mL, of the diverse marks commercialized in supermarkets in the city of Araraquara-SP. Sixty nine samples proceeding from seventeen marks had been used. The samples had been acquired aleatory, at different times and establishments for that they were originated from diverse lots. For analysis of fecal coliform/E. coli and total used it cromogenic substrate technique; for enterococcus and for Pseudomonas aeruginosa was used the technique of multiple tube specific; for counting of heterotrophic bacteria, was used the technique of culture in depth. All the samples of all the marks (100%) had presented absence for fecal coliform/E.coli., two samples (2.9%) of one mark (5.9%) had presented contamination for total coliform, two samples (2.9%), of two marks (11.8%) had presented contamination for enterococcus, three samples (4.3%) of two marks (11.8%) had presented Pseudomonas aeruginosa, and forty samples (58%) of twelve marks (70.6%) had presented counting above of 500 CFU/mL for heterotrophic bacteria. It was verified that, of the sixty nine analyzed samples (100%), only six (8.7%) had been presented contaminated with one or more than the pointers specified for the Brazilian legislation for mineral waters used in this research. However, considering the standards for mineral water and the standard for heterotrophic bacteria established by the legislation for water of human consumption...(Complete abstract click electronic access below) / Mestre
14

Comparação da contaminação microbiana de dois sistemas de encaixe para sobredentaduras mandibulares retidas por implantes. Estudo clínico randomizado / Microbial contamination comparison of two attachment systems for implant retained mandibular overdentures - randomized clinical trial

Pinheiro, Marília Lamenha Lins 30 May 2018 (has links)
A colonização e proliferação de micro-organismos periodontopatogênicos na gengiva marginal aos implantes dentários, assim como ao redor de seus componentes protéticos, pode representar riscos à saúde dos tecidos peri-implantares, à semelhança do que ocorre com os tecidos periodontais. O objetivo deste estudo foi identificar e quantificar 32 espécies microbianas de biofilmes coletados das superfícies de dois sistemas de encaixe para sobredentaduras retidas por implantes: um esférico (Retentive Anchor, Institut Straumann AG, Suíça - RA) e um cilíndrico (Locator, Zest Anchors Inc., CA-USA - Loc), das próteses, implantes e sulcos peri-implantares, ao longo do tempo. Os biofilmes analisados foram coletados em um estudo randomizado envolvendo 24 pacientes portadores de prótese total superior e sobredentadura inferior retida por dois implantes com sistemas de encaixe esférico RA (n= 12) ou cilíndrico Loc (n= 12). Amostras de biofilme foram coletadas de sete sítios para cada implante, nos períodos: após a instalação de novos encaixes (baseline), assim como aos 3 e 12 meses subsequentes. A identificação e quantificação das espécies microbianas foram realizadas por meio da técnica de hibridização DNA-DNA Checkerboard. Os resultados foram submetidos à análise não paramétrica de modelo misto ANOVAF, e matriz de covariância não estruturada para cada tratamento, com nível de significância de 0.05, posteriormente ajustado por Benjamini-Hochberg false discovery rate (FDR). Considerando-se todos os sítios e períodos investigados em conjunto e as 32 espécies bacterianas investigadas, apenas a S. constellatus foi encontrada em maior abundância nos biofilmes associados ao sistema RA. A análise sítio-específica revelou maior prevalência das espécies S. constellatus e P. micra na rosca do componente macho do encaixe esférico RA e da espécie S. sanguinis na superfície externa do componente macho do encaixe cilíndrico Loc. De modo geral, pôde-se concluir que os sistemas de encaixe para retenção de sobredentaduras RA e Loc são colonizados por microbiotas com perfis semelhantes, embora esses sistemas exerçam influência seletiva sobre o padrão de colonização das espécies bacterianas S. constelatus, P. micra e S. sanguinis / The colonization and proliferation of periodontopathogenic microorganisms in the dental implants marginal gingiva, as well as around their prosthetic components, may represent risks to the health of the peri-implant tissues, similar to what occurs with the periodontal tissues. The objective of this study was to identify and quantify 32 microbial species of biofilms collected from the surfaces of two attachment systems for implant retained mandibular overdentures: one spherical (Retentive Anchor, Institut Straumann AG, Switzerland - RA) and one cylindrical (Locator, Zest Anchors Inc., CA-USA - Loc), of prostheses, implants and peri-implant sulcus, over time. The biofilms analyzed were collected in a randomized study involving 24 patients with superior complete dentures and inferior overdenture retained by two implants with spherical attachment RA (n = 12) or cylindrical Loc (n = 12) systems. Biofilm samples were collected from seven sites of each implant, at the periods: after new attachments installation (baseline), as well at the next 3 and 12 months. The microbial species identification and quantification were carried out using DNA-DNA Checkerboard hybridization technique. The results were submitted to the mixed model non-parametric analysis \"ANOVAF\" and non-structured covariance matrix for each treatment, with 0.05 significance level, later adjusted by \"Benjamini-Hochberg\" false discovery rate (FDR). Considering all the sites and periods investigated together and the 32 bacterial species investigated, only S. constellatus was found in greater abundance in the biofilms associated to the RA system. The site-specific analysis revealed a higher prevalence of S. constellatus and P. micra species on the male component of the RA spherical attachment and of S. sanguinis species on the outer surface of the male component of the cylindrical Loc attachment. In general, it can be concluded that the overdenture attachment systems RA and Loc are colonized by microbiotas with similar profiles, although these systems exert a selective influence on the colonization pattern of S. constelatus, P. micra and S. sanguinis bacterial species
15

Caracterização da comunidade bacteriana contaminante do processo fermentativo para produção de etanol e o impacto no metaboloma da fermentação / Characterization of contaminating bacterial community from ethanol fermentation process and the impact on the metabolome

Bonatelli, Maria Letícia 30 September 2016 (has links)
O processo fermentativo da Saccharomyces cerevisiae para a produção de etanol tem grande relevância para o Brasil por ser responsável por uma fonte de energia renovável que é amplamente usada na indústria automotiva. No entanto, em escalas industriais, a fermentação da levedura não ocorre em ambiente asséptico, sendo que diferentes micro-organismos contaminantes são capazes de crescer, competir por nutrientes e até mesmo interferir na fermentação da S. cerevisiae. A fim de melhor compreender quem são os micro-organismos contaminantes e o que fazem na dorna de fermentação, foi utilizado uma abordagem polifásica. O levantamento da microbiota bacteriana presente nas usinas do estado de São Paulo foi realizado através de técnicas independentes de cultivo. Posteriormente, foram realizados ensaios fermentativos com S. cerevisiae CAT-1 na presença do contaminante Lactobacillus fermentum (I-2) para a análise da interação destes na dorna de fermentação. A análise foi realizada por metabolômica acessada através da cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e, para isso, inicialmente foi estabelecida uma metodologia eficiente para análise através de GC-MS. Nas usinas, foi reportada uma porcentagem de Lactobacillus maior do que a descrita e a população bacteriana pareceu ser característica de cada usina e persistente ao longo do tempo. Já o estabelecimento da metodologia de análise de metabólitos da fermentação por GC-MS possibilitou a identificação de 261 metabólitos, e as três classes mais abundantes foram Carbohydrates and carbohydrate conjugates (16%), Carboxylic acids and derivatives (12%) e Fatty Acyls (5%). E no ensaio de S. cerevisiae CAT-1 na presença do contaminante L. fermentum (I-2), possibilitou a identificação de 208 metabólitos, onde 50 foram diferencialmente abundantes. Além disso, a via glicolítica foi reforçada na fermentação de S. cerevisiae CAT-1, sendo que nas fermentações de S. cerevisiae (CAT-1) na presença de L. fermentum (I-2), a produção de aminoácidos a partir do glutamate pareceu ser importante. Desta forma, uma análise polifásica pode auxiliar no esclarecimento da relação dos micro-organismos contaminantes com a levedura dentro da dorna de fermentação. / The fermentation of Saccharomyces cerevisiae for ethanol production has great importance to Brazil since it is responsible for the production of a renewable energy source that is widely used in the automotive industry. However, in industrial scale, the yeast fermentation does not occur in an aseptic environment, where different contaminant microorganisms are capable of growing, competing for nutrients and even interfering with the S. cerevisiae fermentation. In order to better understand who the contaminating microorganisms are and what they do in the fermenter, it was used one polyphasic approach. The survey of the bacterial microflora present in two different São Paulo state distilleries was carried out by cultivation independent techniques. Subsequently, fermentation assays were performed with S. cerevisiae CAT-1 in the presence of the contaminant Lactobacillus fermentum (I-2) to analyze the interaction of these microorganisms in the fermenter. The analysis was performed through metabolomics accessed by gas chromatography-mass spectrometry (GC-MS) and, for that, initially was established an efficient methodology for fermentation metabolite analysis by GC-MS. In the distilleries, it was reported a higher percentage of Lactobacillus than ever described and bacterial population appeared to be characteristic of each distillery and persistent over time. After the establishment of fermentation metabolite analysis methodology by GC-MS, it was possible to identify 261 metabolites, and the three most abundant classes were Carbohydrates and carbohydrate conjugates (16%), Carboxylic acids and derivatives (12%) and Fatty acyls ( 5%). In the fermentation assay of S. cerevisiae CAT-1 in the presence of the contaminant L. fermentum (I-2), it was possible to identify 208 metabolites, where 50 were differentially abundant. In addition, the glycolytic pathway was enhanced in the fermentation of S. cerevisiae CAT-1, and in fermentation of S. cerevisiae (CAT-1) in the presence of L. fermentum (I-2), the production of amino acids from glutamate appeared to be important. Thus, a polyphasic analysis can help in the understanding of the relationship between contaminating microorganisms with the yeast in the fermenter.
16

Efeitos da viabilidade da levedura e da contaminação bacteriana na fermentação alcoólica. / Effects of viability of yeast and bacterial contamination in alcoholic fementation saccharomyces cerevisiae.

Cherubin, Rudimar Antônio 23 May 2003 (has links)
O presente estudo relata a avaliação da metodologia de microplaqueamento em gotas como uma forma alternativa para contagem da bactéria Lactobacillus fermentum CCT 1407 em cultura isolada, ou em cultura mista com Saccharomyces cerevisiae, utilizando o meio de cultivo MRS e actidiona como inibidor da levedura. A análise dos resultados revelou que a metodologia de microplaqueamento em gotas foi equivalente ao plaqueamento em profundidade, o qual é a metodologia rotineiramente utilizada. Este trabalho também relata o comportamento das linhagens Fleischmann, PE-2 e M-26 quando em cultivo misto com a bactéria L. fermentum CCT 1407 durante seis reciclos fermentativos realizados com mosto composto de 30% de melaço e 70% caldo de cana, incubados à temperatura de 32 o C. Foi utilizada a análise de variância para analisar as variáveis e análise sob o esquema parcelas subdivididas no tempo em delineamento blocos ao acaso. Os resultados obtidos mostram que ocorreram reduções de viabilidade nos tratamentos realizados com a linhagem Fleischmann promovendo um estímulo à multiplicação bacteriana, porém, os tratamentos com a linhagem PE-2 apresentaram menores reduções de viabilidade e o estímulo à multiplicação bacteriana foi menor. Ao comparar a o comportamento das linhagens M-26 e PE-2 durante a fermentação em cultivo misto com L. fermentum CCT 1407 não houve diferença estatística significativa, através do teste F, para os seguintes parâmetros: viabilidade celular, rendimento fermentativo, teor alcoólico, massa microbiana e glicerol, sendo detectada diferença significativa para os parâmetros contaminação bacteriana e pH do vinho delevurado. Para o início do experimento comparativo entre as linhagens M-26 e PE-2 foi inoculada a bactéria (1,5.10 6 UFC.mL -1 ) e ao final do sexto ciclo as contaminações foram 3,3.10 7 UFC.mL -1 e 6,0.10 7 UFC.mL -1 nos tratamentos realizados com as linhagens M-26 e PE-2, respectivamente. O aumento da contaminação bacteriana estimulou a formação de glicerol. O teor de trealose apresentou relação positiva com a viabilidade sendo considerado um indicador das condições fisiológicas da levedura, independentemente da linhagem avaliada. / The present study reports the evaluation of pour plate method in drops as an alternative to count the bacteria L. fermentum CCT 1407 in isolated culture, or in mixed culture with Saccharomyces cerevisiae, using the means of cultivation MRS and actidiona as inhibitor of yeast. The analysis of the results revealed that the pour plate method was equivalent to the in depth plate method, which is the methodology most commonly used. This study also presents the behavior of the strain Fleischmann, PE-2 and M-26 when in mixed culture with the bacteria L. fermentum CCT 1407 for six fermentative re cycles accomplished with composed must of 30% of molasses and 70% cane broth, incubated to the temperature of 32 o C. The variance analysis was used to analyze the variables. The obtained results show viability reductions in the treatments accomplished with the strain Fleischmann promoting bacterial multiplication, even so, the treatments with the strain PE-2 presented smaller viability reductions and the incentive to the bacterial multiplication was also smaller. When comparing the behavior of the both strains, M-26 and PE-2, during the fermentation in mixed cultivation with L. fermentum CCT 1407 there was no significant statistical difference, according to the results of the test F, for the following parameters: cellular viability, fermentative output, alcohol content, microbial mass, and glycerol. Significant difference was just detected for the parameters of bacterial contamination and pH of the wine. For the beginning of the first fermentative cycle it was inoculated 1,5.10 6 UFC.mL -1 and at the end of the sixth cycle the contamination was 3,3.10 7 UFC.mL -1 and 6,0.10 7 UFC.mL -1 in the treatments accomplished with the strains M-26 and PE-2, respectively. The increase of bacterial contamination stimulated the glycerol formation and the trehalose content-presented positive relationship with the viability being considered an indicator of the physiologic conditions of the yeast, regardless the appraised yeast strains.
17

Caracterização da comunidade bacteriana contaminante do processo fermentativo para produção de etanol e o impacto no metaboloma da fermentação / Characterization of contaminating bacterial community from ethanol fermentation process and the impact on the metabolome

Maria Letícia Bonatelli 30 September 2016 (has links)
O processo fermentativo da Saccharomyces cerevisiae para a produção de etanol tem grande relevância para o Brasil por ser responsável por uma fonte de energia renovável que é amplamente usada na indústria automotiva. No entanto, em escalas industriais, a fermentação da levedura não ocorre em ambiente asséptico, sendo que diferentes micro-organismos contaminantes são capazes de crescer, competir por nutrientes e até mesmo interferir na fermentação da S. cerevisiae. A fim de melhor compreender quem são os micro-organismos contaminantes e o que fazem na dorna de fermentação, foi utilizado uma abordagem polifásica. O levantamento da microbiota bacteriana presente nas usinas do estado de São Paulo foi realizado através de técnicas independentes de cultivo. Posteriormente, foram realizados ensaios fermentativos com S. cerevisiae CAT-1 na presença do contaminante Lactobacillus fermentum (I-2) para a análise da interação destes na dorna de fermentação. A análise foi realizada por metabolômica acessada através da cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e, para isso, inicialmente foi estabelecida uma metodologia eficiente para análise através de GC-MS. Nas usinas, foi reportada uma porcentagem de Lactobacillus maior do que a descrita e a população bacteriana pareceu ser característica de cada usina e persistente ao longo do tempo. Já o estabelecimento da metodologia de análise de metabólitos da fermentação por GC-MS possibilitou a identificação de 261 metabólitos, e as três classes mais abundantes foram Carbohydrates and carbohydrate conjugates (16%), Carboxylic acids and derivatives (12%) e Fatty Acyls (5%). E no ensaio de S. cerevisiae CAT-1 na presença do contaminante L. fermentum (I-2), possibilitou a identificação de 208 metabólitos, onde 50 foram diferencialmente abundantes. Além disso, a via glicolítica foi reforçada na fermentação de S. cerevisiae CAT-1, sendo que nas fermentações de S. cerevisiae (CAT-1) na presença de L. fermentum (I-2), a produção de aminoácidos a partir do glutamate pareceu ser importante. Desta forma, uma análise polifásica pode auxiliar no esclarecimento da relação dos micro-organismos contaminantes com a levedura dentro da dorna de fermentação. / The fermentation of Saccharomyces cerevisiae for ethanol production has great importance to Brazil since it is responsible for the production of a renewable energy source that is widely used in the automotive industry. However, in industrial scale, the yeast fermentation does not occur in an aseptic environment, where different contaminant microorganisms are capable of growing, competing for nutrients and even interfering with the S. cerevisiae fermentation. In order to better understand who the contaminating microorganisms are and what they do in the fermenter, it was used one polyphasic approach. The survey of the bacterial microflora present in two different São Paulo state distilleries was carried out by cultivation independent techniques. Subsequently, fermentation assays were performed with S. cerevisiae CAT-1 in the presence of the contaminant Lactobacillus fermentum (I-2) to analyze the interaction of these microorganisms in the fermenter. The analysis was performed through metabolomics accessed by gas chromatography-mass spectrometry (GC-MS) and, for that, initially was established an efficient methodology for fermentation metabolite analysis by GC-MS. In the distilleries, it was reported a higher percentage of Lactobacillus than ever described and bacterial population appeared to be characteristic of each distillery and persistent over time. After the establishment of fermentation metabolite analysis methodology by GC-MS, it was possible to identify 261 metabolites, and the three most abundant classes were Carbohydrates and carbohydrate conjugates (16%), Carboxylic acids and derivatives (12%) and Fatty acyls ( 5%). In the fermentation assay of S. cerevisiae CAT-1 in the presence of the contaminant L. fermentum (I-2), it was possible to identify 208 metabolites, where 50 were differentially abundant. In addition, the glycolytic pathway was enhanced in the fermentation of S. cerevisiae CAT-1, and in fermentation of S. cerevisiae (CAT-1) in the presence of L. fermentum (I-2), the production of amino acids from glutamate appeared to be important. Thus, a polyphasic analysis can help in the understanding of the relationship between contaminating microorganisms with the yeast in the fermenter.
18

Įvairių medžiagų, naudojamų karvių speniams paruošti prieš melžimą, poveikio mikroorganizmams tyrimai / Researches of influence on microorganisms of various materials used for cows teats preparation before milking

Miseikienė, Ramutė 22 September 2005 (has links)
Integrated evaluation of materials used for cow teats preparation before milking was carried out. To investigate the efficiency of materials (“Trionet”, “Soap”, “Vissi-Tissi”, “Dermisan”, “ProfilacIopre”, “ProfilacHexopre”, chlorine tablets, wood wool, disposable udder and teats wipes) used for cow teats preparation before milking in our republic and their influence on main indicators of quality of milk (total bacterial contamination, somatic cells count, inhibitory substances in milk). Materials recommended for use as remedies for cow teats preparation before milking imported into Lithuania (such as “Trionet”, “Soap”, “Vissi-Tissi”, “Dermisan”, “ProfilacIopre”, “ProfilacHexopre”, chlorine tablets, wood wool, wet udder wipes “Sowotaan wet”) were investigated and efficiency of their usage was determined. Expediency usage of proposed materials for that purpose in Lithuanian market was evaluated.
19

Antiseptinių medžiagų poveikis pieno bendram bakteriniam užterštumui ir somatinių ląstelių kitimui, sergančių karvių slaptuoju mastitu / Effectiveness of antiseptic materials on bulk milk bacterial contamination, somatic cell count and incidences of sub-clinical mastitis

Banys, Mindaugas 19 April 2007 (has links)
Mastitis causes largest economic losses in dairy production. Sub-clinical mastitis is detected in 50% of lactating cows in Lithuania. Curing effect is transient if major causes and factors of mastitis are not eliminated. Prophylactic measures are directed to strengthen the immune system of the cow and to define and to eliminate all factors causing mastitis. Bacteria are present on skin of the teat in the surroundings. Use of antiseptics of cow teats before and after milking is the most effective preventive procedure that can prevent from new mastitis cases. Antiseptic solutions help to fight most opportunistic and contagious bacterial infections causing mastitis. Teat antiseptics can reduce mastitis incidence by 50 to 75 %. It is recommended to use antiseptic solutions for udder and teats, as they improve physical condition of the udder and milk quality. Agents for udder and teat antiseptics contain bactericidal, skin protecting components in aqueous solution. Bactericidal activity is defined to kill germs during chemical and biological reactions. Active ingredients are iodoforms, chlorhexidins, sodium hypochloride, sodium chloride, lactic acid, hypochloric acid, antimicrobial proteins and fatty acids. Teat dipping reduces bacterial milk contamination, and spreading of pathogens on the teats during the milking. For the present moment this procedure is also used in Europe. Spraying teats with two different concentrations of iodine solution before and after the milking... [to full text]
20

Pieno bakterinio užterštumo nustatymas / Determination of milk bacterial contamination

Melkūnienė, Ingrida 18 June 2014 (has links)
Maisto produktų bakterinis užterštumas yra labai svarbi ir aktuali tema, ypač šiuo metu, kai žmonės grįžta prie natūralaus maisto. Nors maisto produktų saugą reglamentuoja ne vienas teisės aktas, tačiau dėl bakterinės maisto produktų taršos, vis dar kyla dideli epidemijų protrūkiai, kurie sukelia sveikatos sutrikimus tūkstančiams žmonių visame pasaulyje. Darbo tikslas: nustatyti karvių žalio ir pasterizuoto pieno bakterinį užterštumą. Rezultatai: Surinkus žalio ir pasterizuoto pieno mėginius iš skirtingų prekybos vietų ir atlikus tyrimus, nustatyta, kad 44 proc. žalio pieno mėginių viršijo didžiausią leistiną bakterinio užterštumo lygį (EB Nr. 853/2004). Tuo tarpu, nei vienas pasterizuoto pieno mėginys neviršijo leistinos EB Nr. 853/2004 ribos. Palyginus žalio pieno bakterinį užterštumą tarp skirtingų prekybos vietų nustatėme, kad didžiausias užterštumas buvo mėginiuose, imtuose iš ūkininkų, kurie gautą produkciją suvartoja savo reikmėms. Vidutiniškai užteršti – iš ūkininkų, kurie gautą produkciją parduoda, o mažiausiai užteršti mėginiai, imti iš prekybos centruose, esančių automatinių pieno aparatų. Gauti rezultatai parodė, kad 50 proc. žalio pieno mėginių buvo užteršti S. aureus bakterijomis. Nei vienas mėginys neviršijo nustatytos leistinos normos pagal HN 26:2006 „Maisto produktų mikrobiologiniai kriterijai”. Tuo tarpu nei viename pasterizuoto pieno mėginyje S. aureus bakterijos nebuvo išskirtos. Escherichia coli bakterijos nei viename žalio pieno bei pasterizuoto pieno... [toliau žr. visą tekstą] / Bacterial contamination of food products is a very important and relevant topic, especially nowadays, when people are beginning to use natural food again. Although food safety is regulated by more than one legal act, however, due to bacterial contamination of food, there is a large epidemic outbreak, causing health problems for thousands of people around the world. Objective: to determine bacterial contamination of raw and pasteurized cow milk. Results: After collecting samples and carrying out researches of raw and pasteurized milk from different markets, it is determined that 44 % of raw milk samples has exceeded the maximum allowable level of bacterial contamination (EB Nr. 853/2004). Meanwhile none of the samples of pasteurized milk exceeded allowable limits (EB Nr. 853/2004). Comparing bacterial contamination of raw milk between different markets we determined that the highest contamination was found in samples from farmers, who consume production for their own needs. On average contaminated samples was taken from farmers who sells their production. The lowest contamination was found in samples from automatic milk machines from supermarkets. The results showed that 50 % of the raw milk samples were contaminated with S. aureus bacteria. None of samples exceeded the limit laid down in accordance with the HN 26: 2006 "Microbiological criteria for foods". Meanwhile in pasteurized milk samples S. aureus bacteria were not found. Escherichia coli bacteria were not identified in... [to full text]

Page generated in 0.557 seconds