• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimativa da evapotranspira??o sobre a bacia hidrogr?fica do Rio Piranhas-A?u utilizando dados de sensoriamento remoto

Mutti, Pedro Rodrigues 22 February 2018 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-04-02T15:32:36Z No. of bitstreams: 1 PedroRodriguesMutti_DISSERT.pdf: 5339390 bytes, checksum: 305eafacbb12ac9dcc159c054075747f (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-04-06T14:27:48Z (GMT) No. of bitstreams: 1 PedroRodriguesMutti_DISSERT.pdf: 5339390 bytes, checksum: 305eafacbb12ac9dcc159c054075747f (MD5) / Made available in DSpace on 2018-04-06T14:27:48Z (GMT). No. of bitstreams: 1 PedroRodriguesMutti_DISSERT.pdf: 5339390 bytes, checksum: 305eafacbb12ac9dcc159c054075747f (MD5) Previous issue date: 2018-02-22 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A Bacia Hidrogr?fica do Rio Piranhas-A?u (BHPA) est? inserida na regi?o do Semi?rido brasileiro, onde a ocorr?ncia de longos per?odos de estiagem associada aos conflitos na distribui??o dos recursos h?dricos impacta diretamente a disponibilidade de ?gua para abastecimento humano e para o desenvolvimento agr?cola da regi?o. Em virtude disso, o estudo dos processos do ciclo hidrol?gico ? fundamental para a tomada de decis?es no ?mbito do gerenciamento dos recursos h?dricos. Dentre estes processos a evapotranspira??o (ET) se destaca pelo seu papel fundamental nas intera??es entre ?gua, solo e vegeta??o, na modelagem hidrometeorol?gica e nos fluxos de energia em regi?es de clima semi?rido. O objetivo desse estudo ?, portanto, quantificar a ET di?ria em toda a regi?o da BHPA, em um ano seco e um ano chuvoso, utilizando dados de sensores orbitais e formula??es dos algoritmos Simplified Surface Energy Balance Index (S-SEBI) e Simplified Surface Energy Balance (SSEB). Foram utilizados dados de temperatura da superf?cie, albedo e NDVI obtidos pelo sensor orbital MODIS e dados de radia??o solar provenientes das esta??es meteorol?gicas inseridas na bacia. Realizou-se uma an?lise pluviom?trica com dados de precipita??o de postos inseridos na bacia que indicou o ano 2009 como sendo um ano chuvoso e o ano de 2012 como sendo um ano seco, sendo os mesmos escolhidos para quantifica??o da ET. O algoritmo proposto foi calibrado e validado utilizando dados dos elementos do balan?o de energia obtidos em uma torre de fluxo equipada com sistema de eddy covariance. As estimativas da ET di?ria apresentaram boa concord?ncia com os valores observados (R?=0,64, RMSE=0,79 mm.d-1) e o erro relativo da ET anual foi de 7,3% (33,7 mm.ano-1). Em 2009 as maiores taxas mensais de ET foram encontradas nos corpos h?dricos (96,4 mm) e nas regi?es de Caatinga (93,0 mm) em mar?o e abril. Nesse ano, as taxas mensais de ET mantiveram-se maiores que 30,0 mm em todas as classes de uso do solo at? outubro. Em 2012, as maiores taxas foram encontradas tamb?m em mar?o e abril, com destaque para os corpos h?dricos (100,9 mm) e a Caatinga (87,4 mm). Nesse ano, no m?s de junho as taxas de ET atingiram valores inferiores a 30,0 mm, com m?nimo em setembro nas regi?es de solo exposto (17,6 mm). O excedente/d?ficit h?drico foi calculado utilizando-se dados de precipita??o do sat?lite TRMM. No ano de 2009 foi observado um excedente h?drico de 721,5 mm na BHPA, uma magnitude 4,7 vezes maior que o d?ficit observado em 2012 (-153,2 mm). Isso indica que, desconsiderando-se o uso consuntivo dos recursos h?dricos na bacia, anos chuvosos t?m o potencial de compensar at? quatro anos de seca intensa. / The Piranhas-A?u River Basin (PARB) is located in Brazil?s semiarid region, where the occurrence of long draught periods associated with water resources allocation conflicts may put its water availability at risk, impacting human supply and agriculture development. Because of that, research on hydrological cycle processes is crucial to water resources management in water basins. Among these processes, evapotranspiration (ET) is of uttermost importance given its critical role in water, soil and vegetation interactions, hydrometeorological modelling and in the energy fluxes dynamics of semiarid regions. Therefore, the objective of this study is to quantify daily ET during a wet and a dry year in all the PARB, by using remote sensing data and formulations based on the Simplified Surface Energy Balance Index (S-SEBI) and the Simplified Surface Energy Balance (SSEB) algorithms. Land surface temperature, albedo and NDVI data from MODIS sensor and solar radiation data from weather stations located in the basin were used. Precipitation analysis was carried out using data from rain gauges located in the basin. It indicated 2009 as being an unusually wet year and 2012 as an unusually dry year, which were selected for the ET quantification. The proposed algorithm was calibrated and validated with energy balance components data from a flux tower equipped with eddy covariance system. Daily ET estimates showed good agreement with observed values (R?=0.64, RMSE=0.79 mm.d-1) and annual ET relative error was of 7,3% (33.7 mm.year-1). In 2009 the highest monthly ET rates were found in water bodies (96.4 mm) and in the Caatinga (93.0 mm) during March and April. In this year, ET monthly rates were higher than 30.0 mm in all land cover classes until October. In 2012, the highest rates were also found in March and April in water bodies (100.9 mm) and the Caatinga (87.4 mm). In June of this year monthly ET rates were as lows as 30.0 mm, with a minimum of 17.6 mm in bare soil areas in September. Water surplus was calculated using precipitation data from the TRMM satellite. During 2009 it was observed a surplus of 721.5 mm in the PARB, which was 4.7 times greater than the deficit observed in 2012 (-153.2 mm). This indicates that, neglecting consumptive water usage in the basin, wet years can potentially compensate up to four years of intense draughts.
2

Altera??es micrometeorol?gicas causadas pelas mudan?as de uso do solo no Serid? Potiguar

Lima, Jeane Galdino Faustino 30 May 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-10-04T23:59:19Z No. of bitstreams: 1 JeaneGaldinoFaustinoLima_DISSERT.pdf: 1417447 bytes, checksum: 45a8559a124d8412550202f77b1f9a42 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-10-16T20:53:48Z (GMT) No. of bitstreams: 1 JeaneGaldinoFaustinoLima_DISSERT.pdf: 1417447 bytes, checksum: 45a8559a124d8412550202f77b1f9a42 (MD5) / Made available in DSpace on 2017-10-16T20:53:48Z (GMT). No. of bitstreams: 1 JeaneGaldinoFaustinoLima_DISSERT.pdf: 1417447 bytes, checksum: 45a8559a124d8412550202f77b1f9a42 (MD5) Previous issue date: 2017-05-30 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A mudan?a na cobertura do solo provoca altera??es no balan?o de energia e no balan?o h?drico ? superf?cie. O uso inadequado do solo pode levar a uma condi??o de degrada??o avan?ada, a qual ? denominada de processo de desertifica??o. No Brasil, existem v?rios N?cleos de Desertifica??o, dentre os quais o N?cleo de Desertifica??o do Serid? (RN-PB). Assim, o presente trabalho partiu da premissa de que o processo de desertifica??o na regi?o do Serid? Potiguar (RN), possivelmente, tem causado variabilidades na temperatura da superf?cie, no albedo e nos fluxos de energia e massa (evapotranspira??o/fra??o evaporativa). Para comprovar as mudan?as decorrentes deste processo foi realizada uma an?lise descritiva/comparativa entre dados de ?rea degradada e ?rea com Caatinga preservada (Esta??o Ecol?gica do Serid?-ESEC). Para tanto, utilizou-se de um algoritmo h?brido, o qual ? composto de parametriza??es de v?rios algoritmos tais como: o Surface Energy Balance Algorithms for Land/SEBAL, Simplified Surface Energy Balance/SSEB, Simplified Energy Balance Index/S-SEBI, e de imagens TM ? Landsat 5, das ?rbitas-ponto: 215/65, adquiridas gratuitamente junto ao INPE ? Instituto Nacional de Pesquisas Espaciais ? sob a condi??o de c?u claro, para datas dos anos de 1990, 1995, 1998, 1999, 2001, 2003, 2005, 2007. Comparando os resultados obtidos em ?rea degradada e vegetada, foi observado a exist?ncia de diferen?as entre os valores m?dios do albedo, saldo de radia??o e fra??o evaporativa. Esta diferen?a tamb?m foi comprovada de forma significativa por meio de teste estat?stico (teste t de student), o que corrobora a hip?tese de que o processo de desertifica??o derivado do mau uso do solo e das condi??es clim?ticas da regi?o est? causando altera??es nas vari?veis constituintes do balan?o de energia. / The change in soil cover causes changes in the energy balance and surface water balance. Inadequate soil use can lead to an advanced degradation condition, which is called a desertification process. In Brazil, there are several Desertification Nuclei, among which the Serid? Desertification Nucleus (RN-PB). Thus, the present work started from the premise that the desertification process in the Serid? Potiguar (RN) region has possibly caused variability in surface temperature, albedo, and energy and mass fluxes (evapotranspiration / evaporative fraction). To verify the changes resulting from this process, a descriptive / comparative analysis was carried out between degraded area data and preserved Caatinga area (Serid?-ESEC Ecological Station). For this, a hybrid algorithm was used, which is composed of parametrizations of several algorithms such as: Surface Energy Balance Algorithms for Land / SEBAL, Simplified Surface Energy Balance / SSEB, and S-SEBI, and Of images - Landsat 5, of orbits-point: 215/65, acquired free of charge from INPE - National Space Research Institute - under the condition of clear sky, for dates of 1990, 1995, 1998, 1999, 2001, 2003, 2005, 2007. Comparing the results obtained in degraded and vegetated areas, it was observed the existence of differences between the average values of albedo, radiation balance and evaporative fraction. This difference was also significantly demonstrated by means of a statistical test (student's t test), which corroborates the hypothesis that the desertification process derived from the misuse of the soil and the climatic conditions of the region is causing changes in the constituent variables of the Energy balance.
3

An?lise de um queimador infravermelho funcionando com combust?vel h?brido : GLP/Bio-?leo

Azevedo Neto, Alu?sio 19 November 2010 (has links)
Made available in DSpace on 2014-12-17T14:08:43Z (GMT). No. of bitstreams: 1 AluisioAN_DISSERT.pdf: 2010955 bytes, checksum: 9d4c76c749552efd65c7156a389b51c8 (MD5) Previous issue date: 2010-11-19 / Universidade Federal do Rio Grande do Norte / Biomass is considered the largest renewable energy source that can be used in an environmentally sustainable. From the pyrolysis of biomass is possible to obtain products with higher energy density and better use properties. The liquid resultant of this process is traditionally called bio-oil. The use of infrared burners in industrial applications has many advantages in terms of technical-operational, for example, uniformity in the heat supply in the form of radiation and convection, with a greater control of emissions due to the passage of exhaust gases through a macroporous ceramic bed. This paper presents a commercial infrared burner adapted with an ejector proposed able to burn a hybrid configuration of liquefied petroleum gas (LPG) and bio-oil diluted. The dilution of bio-oil with absolute ethanol aimed to decrease the viscosity of the fluid, and improving the stability and atomization. It was introduced a temperature controller with thermocouple modulating two stages (low heat / high heat), and solenoid valves for fuels supply. The infrared burner has been tested, being the diluted bio-oil atomized, and evaluated its performance by conducting energy balance. The method of thermodynamic analysis to estimate the load was used an aluminum plate located at the exit of combustion gases and the distribution of temperatures measured by thermocouples. The dilution reduced the viscosity of the bio-oil in 75.4% and increased by 11% the lower heating value (LHV) of the same, providing a stable combustion to the burner through the atomizing with compressed air and burns combined with LPG. Injecting the hybrid fuel there was increase in the heat transfer from the plate to the environment in 21.6% and gain useful benefit of 26.7%, due to the improved in the efficiency of the 1st Law of Thermodynamics of infrared burner / A biomassa ? considerada a maior fonte renov?vel de energia, podendo ser usada de forma ambientalmente sustent?vel. A partir da pir?lise da biomassa ? poss?vel a obten??o de produtos com maior densidade energ?tica e propriedades de uso melhores. O l?quido resultante do seu processo ? tradicionalmente chamado de bio-?leo. A utiliza??o de queimadores infravermelhos em aplica??es industriais apresenta muitas vantagens do ponto de vista t?cnico-operacional, como por exemplo, homogeneidade no fornecimento de calor, na forma de radia??o e convec??o, apresentando um maior controle das emiss?es devido ? passagem dos gases de exaust?o atrav?s de um leito cer?mico macroporoso. O presente trabalho apresenta um queimador infravermelho comercial adaptado com um ejetor proposto capaz de queimar numa configura??o h?brida de g?s liquefeito de petr?leo (GLP) e bio-?leo dilu?do. A dilui??o do bio-?leo com ?lcool et?lico absoluto teve como principal objetivo diminuir a viscosidade do fluido, e melhorar a estabilidade e a atomiza??o. Foi introduzido um controlador de temperatura com termopar modulando dois est?gios (fogo baixo/alto), e eletrov?lvulas para alimenta??o dos combust?veis. O queimador infravermelho foi submetido a testes e ensaios, sendo atomizado o bio-?leo dilu?do, e avaliado o seu desempenho mediante a realiza??o de balan?o de energia. Como m?todo de an?lise termodin?mica para estimativa de carga foi utilizado uma placa de alum?nio localizada na sa?da dos gases de combust?o, sendo a distribui??o de temperaturas medida por termopares. A dilui??o reduziu a viscosidade do bio-?leo em 75,4% e aumentou em 11% o poder calor?fico inferior do mesmo, propiciando ao queimador uma combust?o est?vel atrav?s da atomiza??o com o ar comprimido e queima conjunta com GLP. Injetando o combust?vel h?brido houve aumento na transfer?ncia de calor da placa para o meio ambiente em 21,6% e ganho energ?tico ?til de 26,7%, em fun??o da melhora na efici?ncia da 1? Lei da Termodin?mica do queimador infravermelho
4

Bio-?leo e biog?s da degrada??o termoqu?mica de lodo de esgoto dom?stico em cilindro rotativo

Pedrosa, Marcelo Mendes 22 December 2011 (has links)
Made available in DSpace on 2014-12-17T15:01:53Z (GMT). No. of bitstreams: 1 MarceloMP_TESE_Parte 1.pdf: 4026465 bytes, checksum: b5bd28c043dc6252575ad902899bb6a6 (MD5) Previous issue date: 2011-12-22 / The objective of this study was to produce biofuels (bio-oil and gas) from the thermal treatment of sewage sludge in rotating cylinder, aiming industrial applications. The biomass was characterized by immediate and instrumental analysis (elemental analysis, scanning electron microscopy - SEM, X-ray diffraction, infrared spectroscopy and ICP-OES). A kinetic study on non-stationary regime was done to calculate the activation energy by Thermal Gravimetric Analysis evaluating thermochemical and thermocatalytic process of sludge, the latter being in the presence of USY zeolite. As expected, the activation energy evaluated by the mathematical model "Model-free kinetics" applying techniques isoconversionais was lowest for the catalytic tests (57.9 to 108.9 kJ/mol in the range of biomass conversion of 40 to 80%). The pyrolytic plant at a laboratory scale reactor consists of a rotating cylinder whose length is 100 cm with capable of processing up to 1 kg biomass/h. In the process of pyrolysis thermochemical were studied following parameters: temperature of reaction (500 to 600 ? C), flow rate of carrier gas (50 to 200 mL/min), frequency of rotation of centrifugation for condensation of bio-oil (20 to 30 Hz) and flow of biomass (4 and 22 g/min). Products obtained during the process (pyrolytic liquid, coal and gas) were characterized by classical and instrumental analytical techniques. The maximum yield of liquid pyrolytic was approximately 10.5% obtained in the conditions of temperature of 500 ?C, centrifugation speed of 20 Hz, an inert gas flow of 200 mL/min and feeding of biomass 22 g/min. The highest yield obtained for the gas phase was 23.3% for the temperature of 600 ?C, flow rate of 200 mL/min inert, frequency of rotation of the column of vapor condensation 30 Hz and flow of biomass of 22 g/min. The non-oxygenated aliphatic hydrocarbons were found in greater proportion in the bio-oil (55%) followed by aliphatic oxygenated (27%). The bio-oil had the following characteristics: pH 6.81, density between 1.05 and 1.09 g/mL, viscosity between 2.5 and 3.1 cSt and highest heating value between 16.91 and 17.85 MJ/ kg. The main components in the gas phase were: H2, CO, CO2 and CH4. Hydrogen was the main constituent of the gas mixture, with a yield of about 46.2% for a temperature of 600 ? C. Among the hydrocarbons formed, methane was found in higher yield (16.6%) for the temperature 520 oC. The solid phase obtained showed a high ash content (70%) due to the abundant presence of metals in coal, in particular iron, which was also present in bio-oil with a rate of 0.068% in the test performed at a temperature of 500 oC. / O objetivo deste trabalho foi produzir biocombust?veis (bio-?leo e g?s), a partir do tratamento t?rmico do lodo de esgoto dom?stico em cilindro rotativo, visando aplica??o industrial. A biomassa foi caracterizada por an?lise imediata e instrumental (An?lise Elementar, Microsc?pica Eletr?nica de Varredura - MEV, Difra??o de Raios-X, Espectroscopia no Infravermelho, ICP-OES). Um estudo cin?tico, em regime n?o estacion?rio foi realizado para o c?lculo da energia de ativa??o por An?lise T?rmica Gravim?trica avaliando os processos termoqu?micos e termocatal?ticos do lodo, sendo este ?ltimo na presen?a da ze?lita USY. Como esperado, a energia de ativa??o avaliada pelo modelo matem?tico "Model-free kinetics" aplicando t?cnicas isoconversionais foi menor para os ensaios catal?ticos (57,9 108,9 kJ/mol, no intervalo de convers?es da biomassa de 40 ? 80%). A planta pirol?tica, em escala de laborat?rio ? constitu?da de um reator de cilindro rotativo cujo comprimento ? 100 cm, com capacidade de processar at? 1 Kg biomassa/h. No processo da pir?lise termoqu?mica foram estudados os seguintes par?metros: temperatura da rea??o (500 ? 600 ?C), vaz?o do g?s de arraste (50 ? 200 mL/min), freq??ncia de rota??o de centrifuga??o (20 ? 30 Hz) para condensa??o do bio-?leo e vaz?o m?ssica de biomassa (4 e 22 g/min). Os produtos obtidos durante o processo (l?quido pirol?tico, carv?o e g?s) foram caracterizados atrav?s de t?cnicas anal?ticas cl?ssicas e instrumentais. O rendimento m?ximo de l?quido pirol?tico foi da ordem de 10,5% obtido nas condi??es de temperatura de 500 ?C, rota??o da centrifuga??o de 20 Hz, vaz?o de g?s inerte de 200 mL/min e vaz?o m?ssica de biomassa 22 g/min. O maior rendimento obtido para a fase gasosa foi de 23,3 %, para a temperatura da rea??o de 600 oC, vaz?o de inerte 200 mL/min, freq??ncia de rota??o da coluna de condensa??o de vapores 30 Hz e vaz?o m?ssica de biomassa de 22 g/min. Os hidrocarbonetos alif?ticos n?o oxigenados foram encontrados em maior propor??o no bio-?leo (55%) seguido pelos compostos alif?ticos oxigenados (27%). O bio-?leo apresentou as seguintes caracter?sticas: pH 6,81, densidade entre 1,05 e 1,09 g/mL, viscosidade entre 2,5 e 3,1 cSt e poder calor?fico superior entre 16,91 e 17,85 MJ/kg. Os principais componentes obtidos na fase gasosa foram: H2, CO, CO2, CH4. O hidrog?nio foi o principal constituinte da mistura gasosa, com rendimento da ordem de 46,2 %, para a temperatura de 600 oC e, dentre os hidrocarbonetos formados, o metano foi encontrado em maior rendimento (16,6 %) para a temperatura 520 oC. A fase s?lida obtida apresentou elevado teor de cinzas (70%), devido ? presen?a abundante de metais no carv?o, em particular, o ferro, o qual esteve tamb?m presente no bio-?leo com um percentual de 0,068 % no ensaio realizado na temperatura de 500 oC
5

An?lise do desempenho de um queimador infravermelho funcionando com g?s liquefeito de petr?leo e glicerina

Dantas, Marcello Ara?jo 31 May 2010 (has links)
Made available in DSpace on 2014-12-17T14:08:39Z (GMT). No. of bitstreams: 1 MarcelloAD_DISSERT.pdf: 3032114 bytes, checksum: 1b49aa6af338e06fe387bb398cc85b4b (MD5) Previous issue date: 2010-05-31 / The use of infrared burners in industrial applications has many advantages in terms of technical-operational, for example, uniformity in the heat supply in the form of radiation and convection, with greater control of emissions due to the passage of exhaust gases through a macro-porous ceramic bed. This paper presents an infrared burner commercial, which was adapted an experimental ejector, capable of promoting a mixture of liquefied petroleum gas (LPG) and glycerin. By varying the percentage of dual-fuel, it was evaluated the performance of the infrared burner by performing an energy balance and atmospheric emissions. It was introduced a temperature controller with thermocouple modulating two-stage (low heat / high heat), using solenoid valves for each fuel. The infrared burner has been tested and tests by varying the amount of glycerin inserted by a gravity feed system. The method of thermodynamic analysis to estimate the load was used an aluminum plate located at the exit of combustion gases and the distribution of temperatures measured by a data acquisition system which recorded real-time measurements of the thermocouples attached. The burner had a stable combustion at levels of 15, 20 and 25% of adding glycerin in mass ratio of LPG gas, increasing the supply of heat to the plate. According to data obtained showed that there was an improvement in the efficiency of the 1st Law of infrared burner with increasing addition of glycerin. The emission levels of greenhouse gases produced by combustion (CO, NOx, SO2 and HC) met the environmental limits set by resolution No. 382/2006 of CONAMA / A utiliza??o de queimadores infravermelhos em aplica??es industriais apresenta muitas vantagens do ponto de vista t?cnico-operacional, como por exemplo, homogeneidade no fornecimento de calor, na forma de radia??o e convec??o, apresentando um maior controle das emiss?es devido ? passagem dos gases de exaust?o atrav?s de um leito cer?mico macroporoso. O presente trabalho apresenta um queimador infravermelho comercial, no qual foi adaptado um ejetor experimental, capaz de promover uma mistura de g?s liquefeito de petr?leo (GLP) e glicerina. Atrav?s da varia??o de percentuais de combust?vel dual, foi avaliado o desempenho do queimador infravermelho mediante a realiza??o de um balan?o de energia e das emiss?es atmosf?ricas. Foi introduzido um controlador de temperatura com termopar modulando dois est?gios (fogo baixo/alto), utilizando v?lvulas solen?ides para cada combust?vel. O queimador infravermelho foi submetido a testes e ensaios variando-se a quantidade de glicerina inserida por um sistema de alimenta??o por gravidade. Como m?todo de an?lise termodin?mica para estimativa de carga foi utilizada uma placa de alum?nio localizada na sa?da dos gases de combust?o, sendo a distribui??o de temperaturas medida por um sistema de aquisi??o de dados que registrou em tempo real as medidas dos termopares afixados. O queimador apresentou uma combust?o est?vel para os n?veis de 15, 20 e 25 % de adi??o de glicerina em raz?o m?ssica de GLP, aumentando o fornecimento de calor para a placa. Pelos dados obtidos, observou-se que houve uma melhora na efici?ncia de 1? Lei do queimador infravermelho quando ocorre o aumento de adi??o da glicerina na mistura. Os n?veis de emiss?es de gases poluentes produzidos pela combust?o (CO, NOx, SO2 e HC) atenderam aos limites estabelecidos pela resolu??o ambiental n? 382/ 2006 do CONAMA.
6

Prot?tipo de uma unidade com tri-gera??o de energia para utiliza??es remotas: aplica??o de m?dulo secondutivo gerador termoel?trico

Santos, Ildefonso Martins dos 27 June 2007 (has links)
Made available in DSpace on 2014-12-17T14:57:39Z (GMT). No. of bitstreams: 1 IldefonsoMS.pdf: 1793001 bytes, checksum: 8b7c737ca595a5f30c4e9de306d3fe97 (MD5) Previous issue date: 2007-06-27 / The generation for termoeletricity is characterized as a solid process of conversion of thermal energy (heat) in electric without the necessity of mobile parts. Although the conversion process is of low efficiency the system presents high degree of trustworthiness and low requisite of maintenance and durability. Its principle is based on the studies of termogeneration carried through by Thomas Seebeck in 1800. The frank development of the technologies of solid state for termoeletricity generation, the necessity of the best exploitation of the energy, also with incentive the cogeneration processes, the reduction of the ambient impact allies to the development of modules semiconductors of high efficiency, converge to the use of the thermoeletric generation through components of solid state in remote applications. The work presents the development, construction and performance evaluation of an prototype, in pilot scale, for energy tri-generation aiming at application in remote areas. The unit is composed of a gas lamp as primary source of energy, a module commercial semiconductor for thermoelectric generation and a shirt for production of the luminosity. The project of the device made compatible a headstock for adaptation in the gas lamp, a hot source for adaptation of the module, an exchanger of to be used heat as cold source and to compose first stage of cogeneration, an exchanger of tubular heat to compose second stage of cogeneration, the elaboration of a converter dc-dc type push pull, adequacy of a system of acquisition of temperature. It was become fullfilled assembly of the prototype in group of benches for tests and assay in the full load condition in order to evaluate its efficiency, had been carried through energy balance of the unit. The prototype presented an electric efficiency of 0,73%, thermal of 56,55%, illumination of 1,35% and global of 58,62%. The developed prototype, as the adopted methodology of assay had also taken care of to the considered objectives, making possible the attainment of conclusive results concerning to the experiment. Optimization in the system of setting of the semicondutor module, improvement in the thermal insulation and design of the prototype and system of protection to the user are suggestions to become it a commercial product / A gera??o por termoeletricidade caracteriza-se como um processo s?lido de convers?o de energia t?rmica (calor) em el?trica sem a necessidade de partes m?veis. Embora o processo de convers?o seja de baixa efici?ncia o sistema apresenta alto grau de confiabilidade e baix?ssimos requisitos de manuten??o e durabilidade. Seu princ?pio ? baseado nos estudos de termogera??o realizados por Thomas Seebeck em 1821. O franco desenvolvimento das tecnologias de estado s?lido para gera??o de termoeletricidade, a necessidade do melhor aproveitamento da energia, inclusive com incentivo a processos de cogera??o, a redu??o do impacto ambiental aliados ao desenvolvimento de m?dulos semicondutores de alta efici?ncia, convergem para o uso da gera??o termoel?trica atrav?s de componentes de estado s?lido em aplica??es remotas. O trabalho apresenta o desenvolvimento, constru??o e avalia??o de performance de um prot?tipo, em escala piloto, para tri-gera??o de energia visando aplica??o em ?reas remotas. A unidade ? composta de um lampi?o a g?s combust?vel como fonte prim?ria de energia, um m?dulo semicondutor comercial para gera??o termoel?trica e uma camisa para produ??o da luminosidade. O projeto do dispositivo compatibilizou um cabe?ote para adapta??o no lampi?o, uma fonte quente para adapta??o do m?dulo, um trocador de calor para ser utilizado como fonte fria e compor o 1? est?gio de cogera??o, um trocador de calor tubular para compor o 2? est?gio de cogera??o, a elabora??o de um conversor cc-cc tipo push pull, adequa??o de um sistema de aquisi??o de temperatura. Realizou-se a montagem do prot?tipo em bancada para testes e ensaio na condi??o de carga plena a fim de avaliar a sua efici?ncia, sendo realizado balan?o de energia da unidade. O prot?tipo apresentou uma efici?ncia el?trica de 0,73%, t?rmica de 56,55%, de ilumina??o de 1,35% e global de 58,62%. O prot?tipo desenvolvido, como tamb?m a metodologia de ensaio adotada atenderam aos objetivos propostos, possibilitando a obten??o de resultados conclusivos acerca do experimento. Otimiza??o no sistema de fixa??o do m?dulo semicondutor, melhoramento na isola??o t?rmica e design do prot?tipo e sistema de prote??o ao usu?rio s?o sugest?es para torn?-lo um produto comercial

Page generated in 0.1012 seconds