• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 22
  • 11
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 97
  • 97
  • 47
  • 40
  • 36
  • 34
  • 28
  • 26
  • 25
  • 25
  • 22
  • 20
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Nosná konstrukce vícepodlažního železobetonového objektu / The load bearing structure of multi-storey reinforced concrete builidng

Burda, Patrik January 2018 (has links)
The diploma thesis is focused on design on loadbearing reinforced concrete structure of multi-storey apartment building with shops and offices on the ground floor and underground garage. The thesis consists of the analysis and design of ceiling slabs above underground floor, supporting columns and the beam under the underground floor ceiling slab. Calculation 3D model was created to determine internal forces. All structures are designed according to EC2, ČSN EN 1992-1-1. The thesis includes elaboration of static calculation, shape drawings, drawings of reinforcement of solved structures. The rest of the project part are not analysed.
92

Statické posouzení stávajícího železobetonového skeletu výrobního objektu / Structural assessment of the existing reinforced-concrete frame structure of the production building

Pražan, Jiří January 2019 (has links)
The diploma thesis deals with the structural assessment of the existing reinforced concrete frame structure of the production building. The structure under consideration is carried out as a reinforced concrete monolithic frame structure with a discrepancy of 6,15 x 6,15 m (axis). The object has a rectangular plan of 13 x 9 fields. The total dimension is 56 x 81m and is divided into three dilation units on all floors by two inserted 3,65 m wide fields. The building has three above-ground floors and one underground floor. The construction height of the basement is 3,675 m, above ground level 4,0 m. On the west side of the building (axis A) are three reinforced concrete elevator shafts with a dimension of approximately 4,5 x 3,8 m. The envelope and inner partitions are made of bricks full of burned. The work shall include a static assessment of the status quo, a determination of the load capacity and a proposal for appropriate adjustments to ensure static reliability.
93

Průzkum a hodnocení mostu na dálnici D2 / Survey and Assessment of highway D2 Bridge

Výpustek, Libor January 2013 (has links)
This thesis deals with the exploration and evaluation of the existing bridge carried him on the highway D2. The work is divided into theoretical and practical parts. The theoretical part focuses on the technical surveys, diagnosis of building structures and some methods of investigation and testing of building structures. In the practical part the visual inspection and diagnosis of disorders of the highway bridge substructures ev. No. D2-058, to determine material characteristics substructure and evaluate the state of the bridge. In conclusion, the practical part of the recommendations for the design and method of repairing the bridge.
94

Probabilistic Characterization of Bond Behavior at Rebar-concrete Interface in Corroded RC Structures: Experiment, Modeling, and Implementation

Soraghi, Ahmad January 2021 (has links)
No description available.
95

Behaviour of three-dimensional concrete structures under concurrent orthogonal seismic excitations

Zaghlool, Baher SalahElDeen Othman Ahmed January 2007 (has links)
This thesis is a study into the response and seismic safety of three-dimensional multi-storey concrete structures under concurrent orthogonal seismic excitations. It employs the nonlinear time-history method as its analysis tools. Time-history analyses rely heavily on their utilised earthquake records. Accordingly, this study examines the different approaches of selecting earthquake suites and develops a methodology of selecting representative earthquake scenarios. This methodology is credibly implemented in selecting a far- and a near field suites representative of the New Zealand seismic hazard. The study investigates the response of 6-, 9- and 12-storey concrete structures of different n-X-bays × m-Y-bays. Bidirectional responses of these considered structures are examined and consequently the current combination rules are scrutinised. Consequently this study strongly recommends the use of the 40-percent combination rule in lieu of the widely used 30-percent rule; and the use of time-history analysis in lieu of quasi/equivalent static and response modal analysis methods to avoid their strong dependence on combination rules. An intensive study is conducted employing the incremental dynamic analysis (IDA) technique to investigate structural demands of interstorey drifts, lateral storey drifts and storey accelerations. The study utilises the developed far-field suite and identifies the 50th and 90th percentile demands. Hence it provides easy-to-use expressions to facilitate rapid calculation of the structural demands and the effects of biaxial interactions. An implementation into the Demand and Capacity Factor Design (DCFD) format is presented that infers confidence in the performance levels of the considered structures. The study also draws attention to the importance of considering storey accelerations as their storey values reach as high as 10 × PGA. A sensitivity study is conducted by repeating the IDA investigation while using the developed near-field suite. Subsequently a comparison between the near- and the far-field results is conducted. The results were markedly similar albeit of less magnitudes until the (seismic hazard) intensity measure IM = Sa(T₁) = 0.4g when the near-field results show sudden flat large increase in demands suggesting a brittle collapse. This is attributed to the higher content of the higher mode frequencies contained in near-field ground motions. Finally, the study examines the (vectorial) radial horizontal shear demands in columns and beam-column joints of the previous far- and near-field studies. The combined radial shear demands in corner, edge and internal columns and joints are evaluated that roughly show a square-root proportional relationship with IM that exhibit somewhat brittle failure at IM ≥ 0.35g. Shears demands in the (4-way) internal columns and the (2-way) corner joints show highest magnitude in their respective class. The results suggest transverse joint shear reinforcement of 1.5, 1.0 and 0.5 of the longitudinal reinforcement of the neighbouring beam respectively for corner, edge and internal joints. An implementation of a proposed practical (and simpler) DCFD format shows satisfactory confidence in columns performance in shear up to IM = 0.35g, conversely to joints unsatisfactory performance in shear at the onset of inelastic behaviour (IM > 0.05g).
96

Ocelová konstrukce průmyslové budovy / Steel structure of an industrial building

Kopecký, Ladislav January 2016 (has links)
Industrial hall with storage outbuilding. The length of the hall is 72 meters and width of 30 meters. The main hall has a span 24 meters and the outbuilding has a span 6m. The distance between primary steel frame is 6 meters. The height of the main hall is 10.7 meters and a height of outbuilding is 13.0 metres. The roof is flat with roof slope of 3.5% the main hall and 8.75% outbuilding. The structural system of the hall's bar structure. Primary steel frame is designed as a steel frame rafter with eaves haunch. In the roof structure are designed purlins. The stability of the structure is secured by roof braces and longitudinal braces. The hall is pin-supported on the foundation pad. The hall is clad wall and roof panels PUR. Main hall is equipped with a bridge crane with capacity of 8 tons.
97

Rehabilitation of Exterior RC Beam-Column Joints using Web-Bonded FRP Sheets

Mahini, Seyed Saeid Unknown Date (has links)
In a Reinforced Concrete (RC) building subjected to lateral loads such as earthquake and wind pressure, the beam to column joints constitute one of the critical regions, especially the exterior ones, and they must be designed and detailed to dissipate large amounts of energy without a significant loss of, strength, stiffness and ductility. This would be achieved when the beam-column joints are designed in such a way that the plastic hinges form at a distance away from the column face and the joint region remain elastic. In existing frames, an easy and practical way to implement this behaviour following the accepted design philosophy of the strong-column weak-beam concept is the use a Fibre Reinforced Plastic (FRP) retrofitting system. In the case of damaged buildings, this can be achieved through a FRP repairing system. In the experimental part of this study, seven scaled down exterior subassemblies were tested under monotonic or cyclic loads. All specimens were designed following the strong-column weak-beam principal. The three categories selected for this investigation included the FRP-repaired and FRP-retrofitted specimens under monotonic loads and FRP-retrofitted specimen under cyclic loads. All repairing/retrofitting was performed using a new technique called a web-bonded FRP system, which was developed for the first time in the current study. On the basis of test results, it was concluded that the FRP repairing/retrofitting system can restore/upgrade the integrity of the joint, keeping/upgrading its strength, stiffness and ductility, and shifting the plastic hinges from the column face toward the beam in such a way that the joint remains elastic. In the analytical part of this study, a closed-form solution was developed in order to predict the physical behaviour of the repaired/retrofitted specimens. Firstly, an analytical model was developed to calculate the ultimate moment capacity of the web-bonded FRP sections considering two failure modes, FRP rupture and tension failure, followed by an extended formulation for estimating the beam-tip displacement. Based on the analytical model and the extended formulation, failure mechanisms of the test specimens were implemented into a computer program to facilitate the calculations. All seven subassemblies were analysed using this program, and the results were found to be in good agreement with those obtained from experimental study. Design curves were also developed to be used by practicing engineers. In the numerical part of this study, all specimens were analysed by a nonlinear finite element method using ANSYS software. Numerical analysis was performed for three purposes: to calculate the first yield load of the specimens in order to manage the tests; to investigate the ability of the web-bonded FRP system to relocate the plastic hinge from the column face toward the beam; and to calibrate and confirm the results obtained from the experiments. It was concluded that numerical analysis using ANSYS could be considered as a practical tool in the design of the web-bonded FRP beam-column joints.

Page generated in 0.037 seconds