• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 10
  • 10
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contributions à l'analyse d'images médicales pour la reconnaissance du cancer du sein / Contributions to medical images analysis for breast cancer recognition

Goubalan, Sègbédji Rethice Théophile Junior 09 December 2016 (has links)
Le diagnostic assisté par ordinateur du cancer du sein suscite de plus en plus un réel engouement en raison de la quantité sans cesse croissante d'images mammographiques issues des campagnes de dépistage. L'accent est mis sur les opacités mammaires en raison du risque élevé de cancer qui leur est associé. En effet, la variabilité des formes rencontrées et la difficulté à discerner les masses surtout quand ces dernières sont embarquées dans des densités importantes exigent une nouvelle stratégie plutôt adaptée aux cas les plus complexes à savoir les masses appartenant aux classes BI-RADS IV et V, c-à-d. respectivement les masses malignes spiculées et les distorsions architecturales. Dans ce travail, un système de diagnostic assisté par ordinateur entièrement automatique et conçu pour la segmentation et la classification des opacités dans les catégories bénigne/maligne ou graisseuse/dense, spécifiquement pour celles de type BI-RADS IV et V est abordé. Dans un premier temps, nous avons développé une approche de pré-traitement des images fondée sur l'apprentissage d'un dictionnaire parcimonieux sur les bases d'images, combiné à une réduction de dimension afin de supprimer de façon efficace et rapide le bruit de numérisation des images mammographiques présentes dans les bases utilisées pour concevoir notre système de diagnostic en comparaison des approches déjà existantes. Une fois les images pré-traitées, nous avons mis en place une procédure de segmentation non-supervisée des masses basée sur les champs de Markov et qui a l'avantage d'être à la fois plus rapide, plus efficace et plus robuste que les meilleures techniques de segmentation disponibles dans l'état-de-l'art. De plus, la méthode proposée s'affranchit de la variabilité des masses et ce quelque soit la densité de l'image. Dans l'idée de décrire convenablement les lésions malignes spiculées, nous avons conçu une méthode de segmentation des spicules qui présente la particularité de ne pas recourir à l'utilisation de descripteurs extraits manuellement dont les performances peuvent varier en fonction de leur qualité. L'approche proposée repose sur des hypothèses que nous avons formulées concernant l'aspect des spicules. Celles-ci nous ont conduits à développer un modèle Markovien combiné à une transformée de Radon locale pour extraire les structures curvilignes de l'image. Ensuite, nous servant d'un modèle a contrario, nous avons pu extraire les spicules de l'ensemble des structures détectées. Cette phase, vient clore la première partie de la conception de notre système, qui est en mesure d'extraire soit des masses spiculées, soit des distorsions architecturales. Afin de finaliser sa conception, nous avons procédé à la création d'un modèle d'aide à la décision qui, à l'inverse de ce qui s'est toujours fait dans l'état-de-l'art pour la discrimination des masses, procède à une extraction non-supervisée des descripteurs à l'aide d'une méthode issue du Deep learning, à savoir les réseaux de neurones à convolution. Les descripteurs extraits, sont ensuite utilisés dans un classifieur SVM pour apprendre un modèle. Ce modèle servira par la suite à la reconnaissance du cancer du sein. Les résultats obtenus pour chacune des étapes du système de diagnostic sont très intéressants et viennent combler un vide important dans la classification des masses en général et dans la distinction des masses malignes entre elles en particulier en se fondant sur trois niveaux de décision que sont la forme, la densité et les spicules. / Computer-aided diagnosis of breast cancer is raising increasingly a genuine enthusiasm because of the ever-increasing quantity of mammographic images from breast cancer screening campaigns. The focus is on breast masses due to the high risk of cancer associated with them. Indeed, the variability of shape encountered and the difficulty to discern the masses especially when theyare embedded in a high density require a new approach especially suited for the most complex cases namely the masses which belong to classes BI-RADS IV and V, i.e. spiculated breast mass and architectural distortion. In this work, a fully automatic computer-aided diagnosis system is designed for the segmentation and classification of breast mass especially for malignant masses of classes BI-RADS IV and BI-RADS V. Initially, we developped a pre-processing method combined with the reduction of the dictionary size in order to remove effectively and quickly the digitization noise of the mammographic images that make up the database used to design our computer-aided diagnosis system in comparison with the existing approaches. After the image pre-processing, we haveproposed an unsupervised segmentation method based on a Markov random field which has the advantage of being faster, more efficient and more robust than the state-of-art segmentation methods. Furthermore, the proposed method overcomes the variability of the breast masses whatever the image density. In purpose to describe correctly the spiculated malignant lesions, we proposed anapproach which avoid the computation and extraction of local features, and to rely on general-purpose classification procedures whose performance and computational efficiency can greatly vary depending on design and image characteristics. The proposed method is based on several assumptions on the structure of spicules as they appear in mammograms which have been reported in the literature. In order to make use of the above assumptions, the proposed method proceeds the following steps: first the mammogram is separated into patches onto which the curvilinear structures are discretized into segments due to Radon transform. Then, Markov modeling and contextual information are used to refine the segment positions and associate segments into curvilinear structures. Finally, spicules are detected based on a contrario model. This stage conclude the first part of the design of our computer-aided diagnosis system, that is able to extract both spiculated masses and architectural distortion. In order to complete the design of the diagnosis system, we carried out the creation of a decision support model which, contrary to what has always been done in the state-of-art for discrimination of the masses, conducts an unsupervised extraction of features through Deep learning approach - namely convolutional artificial neural networks -, combined with an SVM-type classifier. The obtained model is then stored and used as a classifier for breast cancer recognition tasks during the generalization phase. The results obtained for each step of the design of our system are very interesting and come to fill an important gap in the distinction of different type of malignant masses.
2

A core biopsy estereotáxica no diagnóstico das lesões mamárias impalpáveis altamente suspeitas de malignidade (categoria mamográfica BI-RADS® 5): um estudo de correlação radiologia/anatomia patológica

Ferreira Lima Júnior, Álvaro January 2007 (has links)
Made available in DSpace on 2014-06-12T23:04:14Z (GMT). No. of bitstreams: 2 arquivo8851_1.pdf: 4717828 bytes, checksum: 592acd5b2b91d1cead758a1666f091db (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / As indicações clínicas da core biopsy obedece aos mesmos critérios utilizados para biópsia cirúrgica, mas não há consenso na literatura quanto a sua indicação para avaliação das lesões na categoria mamográfica BI-RADS® 5 (ACR/Breast Imaging Reporting and Data System). Objetivo: Determinar a associação entre as alterações mamográficas e o diagnóstico histopatológico de material obtido por core biopsy estereotáxica de lesões mamárias impalpáveis classificadas na categoria mamográfica BI-RADS® 5, estabelecendo o valor preditivo positivo da mamografia nas lesões altamente suspeitas de malignidade. Materiais e métodos: Por meio de estudo retrospectivo, transversal, analítico, de comparação entre métodos diagnósticos, foram analisadas 70 core biopsies de lesões mamárias impalpáveis, classificadas radiologicamente como altamente suspeitas de malignidade (BI-RADS® 5), de 70 pacientes, atendidas em serviços privados de Anatomia Patológica e Radiologia da cidade do Recife, Pernambuco, no período de 2001 a 2006. Resultados: Eram do sexo feminino 68 (97,1%) pacientes e 2 (2,9%), do masculino. A idade variou de 17 a 87 anos, com média de 58 ± 15 anos. A mama esquerda foi acometida em 42 (60%) casos e a direita, em 28 (40%). Predominaram localização das lesões no QSE (44 casos; 62,9%) e nódulos irregulares espiculados (49 casos; 70%), 11 (15,7%) dos quais associados a microcalcificações. As microcalcificações estavam presentes em 31(44,3%) casos; sendo 16 (22,9%) casos não associados a nódulos, distorção arquitetural ou densidade assimétrica. As core biopsies foram constituídas por 3 a 16 fragmentos (média: 6±2). Não houve diferença na distribuição de freqüência de número de fragmentos em função dos diagnósticos histopatológicos (p>0,05) ou radiológicos (p=0,63). Houve diagnóstico de: 59 (84,3%) casos de carcinoma, 7 (10%) casos de lesões benignas e 4 (5,7%) com lesão borderline. O carcinoma invasivo foi o mais freqüente (49 casos; 70%) e em 15 (21,4%) casos associou-se a componente in situ. O carcinoma in situ puro correspondeu a 10 (14,3%) casos. Houve associação significante entre nódulos irregulares espiculados e carcinoma invasivo (41 casos; 58,6%; p=0,005). O tipo histológico mais encontrado foi o carcinoma ductal invasivo (34 casos; 69,4%). Dentre os carcinomas invasivos, 36 (73,5%) casos tiveram grau histológico 2, com predomínio da soma dos escores igual a 6 (34 casos; 69,4%). O CDIS padrão comedônico puro associou-se mais freqüentemente às microcalcificações. O valor preditivo positivo da avaliação mamográfica na categoria BI-RADS® 5 foi de 84,3%. O maior valor preditivo positivo foi verificado em nódulo irregular espiculado com microcalcificações, com ou sem, sem microcalcificações e microcalcificações sem nódulo (100%, 87,8%, 84,2% e 75%, respectivamente). Conclusões: A avaliação mamográfica das lesões impalpáveis enquadradas como altamente suspeitas de malignidade foi de alto valor preditivo para o diagnóstico de câncer, a maioria correspondendo a carcinoma invasivo. Os nódulos irregulares espiculados tiveram um alto valor preditivo para o diagnóstico de carcinoma, particularmente, quando associados às microcalcificações
3

Achados mamográficos e anátomopatológicos de mulheres participantes de campanhas de rastreamento para câncer de mama em centro de referência em oncologia

Aguiar, Renata Mara Bueno 11 December 2013 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2015-07-27T13:39:57Z No. of bitstreams: 1 Renata Mara Bueno Aguiar.pdf: 3052806 bytes, checksum: 7fc933a7df31cf76bd53ddfab6dc00d3 (MD5) / Made available in DSpace on 2015-07-27T13:39:57Z (GMT). No. of bitstreams: 1 Renata Mara Bueno Aguiar.pdf: 3052806 bytes, checksum: 7fc933a7df31cf76bd53ddfab6dc00d3 (MD5) Previous issue date: 2013-12-11 / Objective: To analyze the mammographic radiologic findings during screening campaigns of a Brazilian Oncology Center. The mammographic radiologic findings, the complementary diagnostic tests eventually requested and the patient’s adherence to the screening recommendations were studied. Methods: A retrospective study was conducted including all 771 patients that participated in the stimulated and gratuitous screening program of the A. C. Camargo Cancer Center, São Paulo, Brazil, during 2008. The patient’s records were analyzed in order to obtain result from mammography tests, breast ultrasonography, biopsies and surgeries. Results: The women`s age varied from 24 to 107 years old. (average: 55 years old), 259 (34%) under 50 years old, 423 (55%) between 50 and 69 years old and 89 (11%) older than 69 years old. The mammography results were classified as follows: BI-RADS 0 =186 (25,1%), BI-RADS 1 = 114 (14,8%), BI-RADS 2 =395 (51,2%), BI-RADS 3 =50 (6,5%), BI-RADS 4 = 16 (2,1%) e BI-RADS 5 =2 (0,3%). Complementary ultrasonography exam was performed in 184 (24%) of all patients. Thirty three (4%) lesions were submitted to histopathological analyses revealing 6 (8%) cases of cancer. They were 3 invasive ductal carcinomas, 2 in situ ductal carcinomas and 1 lobular carcinoma in situ. Five of those cancers were surgically classified as Stage 1 disease and One as Stage 2 disease. After 4 years 87 (15%) patients returned for new screening exams. Conclusion: There was a meaning ratio of patients out of Brazilian National Cancer Institute (INCA) recommendation for breast cancer screening. The rates of complementary ultrasonography were high. The number of patients diagnosed with cancer and the rates of diagnoses in initial grades are in consonance with the literature. The opportunistic screening model revealed low return rate for new screening tests. / Objetivo: Analisar durante uma campanha de rastreamento para câncer de mama realizada em um Centro Brasileiro de Oncologia. Foram estudados os achados radiológicos das mamografias e as eventuais recomendações de testes diagnósticos complementares e a adesão das pacientes a essas recomendações. Metodologia: Esta foi uma análise retrospectiva incluindo todas as 771 pacientes que participaram das campanhas estimulada e gratuita de rastreamento para câncer de mama do A. C. Camargo Cancer Center, em São Paulo, Brasil, no ano de 2008. Foram avaliados os resultados de mamografias, ultrassonografias, biópsias e cirurgias de mama realizadas. Para os diagnósticos de câncer registramos a histologia e o estadiamento clínico da doença. Resultados: A idade das mulheres variou de 24 a 107 anos (média: 55 anos), 259 (34%) com idade inferior a 50 anos, 423 (55%) com idade entre 50 e 69 anos e 89 (11%) com idades maiores que 69 anos. A classificação segundo o BI-RADS do resultado das mamografias foi: BI-RADS 0 186 (25,1%), BI-RADS 1 114 (14,8%), BI-RADS 2 = 395 (51,2%), BI-RADS 3 = 50 (6,5%), BI-RADS 4 =16 (2,1%) e BI-RADS 5 = 2 (0,3%).O exame ultrassonográfico complementar à mamografia foi realizado por 184 (24%) da amostra. Foram realizadas 33 (4%) investigações anátomo-patológicas identificando 6 (8%) casos de câncer, 3 Carcinomas ductais invasivos, 2 carcinomas ductais in situ e 1 carcinoma lobular in situ. O estadiamento cirúrgico dessas neoplasias foi Estadio 1 para 5 pacientes e Estadio 2 em uma paciente. A revisão dos registros realizada após 4 anos identificou 87 (15%) pacientes que haviam retornado ao serviço para novos exames de rastreamento ao menos uma vez. Conclusão: Uma proporção significativa das pacientes de campanha está fora da faixa etária de recomendação do Instituto Nacional do Câncer do Ministério da Saúde (INCA) para rastreamento do câncer de mama. As taxas de complementação com ultrassonografia foram elevadas. O número de cânceres e a taxa de diagnósticos em estádio inicial estão em consonância com os índices preconizados. O modelo de rastreamento oportunístico mostrou baixa taxa de retorno periódico ao mesmo serviço.
4

Estudo descritivo das mamografias categorias IV e V da classificação BI-RADS

Giandon, Carlos Alberto da Silva [UNESP] 30 October 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-10-30Bitstream added on 2014-06-13T19:13:27Z : No. of bitstreams: 1 giandon_cas_me_botfm_prot.pdf: 2640324 bytes, checksum: 4b109b85ba7836d8177933cba98a32e4 (MD5) / Fundação para o Desenvolvimento Médico e Hospitalar (Famesp) / O câncer de mama é um problema de saúde pública, com 49.470 casos em 2005 no Brasil. A mamografia é o método de escolha para rastreamento e diagnóstico precoce do câncer de mama. O sistema BI RADS veio tentar organizar e padronizar os laudos mamográficos. O VPP do Bl-RADS IV varia de 2 a 90% e da categoria V > 90%. Objetivos: avaliar as principais características das lesões mamográficas suspeitas e calcular o VPP da categoria IV e V. Sujeitos e métodos: foram estudados 309 laudos mamográficos de Bl-RADS IV e V e correlacionados com seus resultados de histopatológicos. A análise estatística foi o teste diagnóstico do VPP. Resultados: idade média 54 anos, mama esquerda acometida em 165 (53,4%) pacientes e mama direita em 144 (46,6%) pacientes, BI RADS IV 265 (85,8%), Bl-RADS V 44 (14,2%), lesões benignas 163 (52,8%), lesões proliferativas de risco 48 (15,5%), lesões malignas 98 (31,7%). Os principais achados mamográficos na categoria IV foram as microcalcificações 163 (61,5%) e na categoria V foram os nódulos em 22 (50,0%). A modalidade de biopsia mais usada na categoria IV foi o agulhamento mamário em 188 (70,9%) e na categoria V foi à biopsia per cutânea em 16 (36,4%). O carcinoma ductal infiltrante foi o tipo histológico mais freqüente na categoria IV em 45 (78,9%) e na categoria V em 35 (85,4%) pacientes. O VPP para a categoria IV foi de 39,2% e da categoria V de 95,5%. Conclusão: Concluímos que os principais achados mamográficos na categoria IV foram as microcalcificações, com VPP desta categoria de 39,2%; na categoria V foram os nódulos os principais achados mamográficos, com VPP de 95,5%, valor este que confirma esta categoria como alta probabilidade de malignidade. / Breast cancer is a serious world health problem. The mammography is the better method for the screening of earlier breast cancer. The Bl-RADS system was introduced to standardize the report results. Bl-RADS IV has a Positive Predictive Value (PPV) ranged from 2 to 90% and over 90% to category V. Objectives: to evaluate the principal characteristics of the suspicious mammographic lesions and calculate PPV of the Bl-RADS category IV and V. Subjects and methods: it was evaluated 309 reports of mammographic abnormalities classified as Bl-RADS IV and V; and their correlations with biopsies results. Resulted: medium age was 54 years, the lesions occurred in 165 left-sided breast (53.4%) and in 144 right-sided breast (46.6%). Bl-RADS IV pattern was identified in 265 (85.8%) reports and BI-RADS V in 44 (14.2%). Benign lesions were found in 163 reports (52.8%), proliferative risk lesions were found in 48 (15.5%), malign lesions were found in 98 (31.7%). The principal mammographic lesion was the microcalcification in category IV and nodules were in category V. The most used procedure for diagnosis was core biopsy in 204 patients (66%). The invasive ductal carcinoma was the predominant histological type in malignant breast tumors. PPV of 39.2% was observed for BI-RADS IV and for BI-RÃDS V was 95.5%. Conclusion: the principal mammographic pattern lesion in the Bl-RADS IV was the microcalcification, with PPV of 39.2% and the nodules were the principal mammographic pattern lesions in the BI-RADS V with PPV of 95.5%. It confirms the high probability of malignancy in BI-RADS V category.
5

Organização automática de bancos de mamografias no padrão de densidade BI-RADS / Automatic organization of mammography database of the density patterns described in the BI-RADS

Rodrigues, Silvia Cristina Martini 30 August 2004 (has links)
Este trabalho apresenta um método computacional que classifica as mamografias no padrão de densidade BI-RADS, visando auxiliar a detecção precoce do câncer de mama, seja essa realizada por análise visual ou por auxílio computadorizado. A classificação das mamografias em bancos padronizados objetiva eliminar conflitos entre laudos mamográficos de diferentes profissionais, bem como quanto à conduta médica a ser seguida. Entretanto, o estabelecimento de bancos feito visualmente e principalmente em períodos diferentes dificulta sua uniformização, proporcionando uma classificação muito subjetiva e relativamente grosseira em conseqüência a grande variação entre e inter observadores. O método desenvolvido permitiu classificar as imagens independentemente da subjetividade própria à observação visual de quem organizou o banco ou da técnica de exposição aos raios X utilizada. Os resultados foram superiores a 92% mesmo para bancos de imagens totalmente diferentes. Esses resultados foram obtidos respeitando-se as possíveis diferenças de interpretações de diversas equipes médicas. Além do estabelecimento de banco de mamografias com limiares entre as composições bem quantificadas, com esta ferramenta, tanto os estagiários poderão ser treinados para classificar as imagens no padrão de densidades do BI-RADS, respeitando as particularidades locais, quanto os resultados dos CAD poderão ser comparados. / This thesis presents a computational method that classifies the mammography into the composition of the breast tissue density patterns described in the BI-RADS protocol, intended to help in the early detection of breast cancer, either if this detection happens to be realized by visual analysis or by computerized support. The classification of the mammography in standardized database intends to eliminate issues between mammography awards of distinct professionals and the correct medical conduct to be followed. However, the determination of database only visually, especially in different periods, difficult it\'s to standardize, causing an extremely subjective classification and relatively superficial in consequence of the large inter-and intraobserver variability. The method allows classifying the images independently of the subjective quality of the visual analysis from who organized the database or from the technique of the exposition to X-ray employed. The results were superior of 92% even to database totally distinct. These results were obtained respecting eventual differences of interpretation from several medical groups. Beside the establishment of mammography database with thresholding between the well quantified categories, this methodology will consent to probationers to be trained for classify the images according to the composition of the breast tissue density patterns described in the BI-RADS, respecting its local particularity. Likewise, with this methodology, the results from CAD would be compared.
6

Korrelation der Magnet-Resonanz (MR)-Mammographiebefunde, unter Berücksichtigung der BI-RADS-Klassifikation, mit dem Pathologischen Befund / Correlation of the magnet resonance (MR) - mammography findings, taking into account the BI-RADS-classification, with the pathological findings

Scherrer, Martin Nikolas 10 May 2010 (has links)
No description available.
7

Organização automática de bancos de mamografias no padrão de densidade BI-RADS / Automatic organization of mammography database of the density patterns described in the BI-RADS

Silvia Cristina Martini Rodrigues 30 August 2004 (has links)
Este trabalho apresenta um método computacional que classifica as mamografias no padrão de densidade BI-RADS, visando auxiliar a detecção precoce do câncer de mama, seja essa realizada por análise visual ou por auxílio computadorizado. A classificação das mamografias em bancos padronizados objetiva eliminar conflitos entre laudos mamográficos de diferentes profissionais, bem como quanto à conduta médica a ser seguida. Entretanto, o estabelecimento de bancos feito visualmente e principalmente em períodos diferentes dificulta sua uniformização, proporcionando uma classificação muito subjetiva e relativamente grosseira em conseqüência a grande variação entre e inter observadores. O método desenvolvido permitiu classificar as imagens independentemente da subjetividade própria à observação visual de quem organizou o banco ou da técnica de exposição aos raios X utilizada. Os resultados foram superiores a 92% mesmo para bancos de imagens totalmente diferentes. Esses resultados foram obtidos respeitando-se as possíveis diferenças de interpretações de diversas equipes médicas. Além do estabelecimento de banco de mamografias com limiares entre as composições bem quantificadas, com esta ferramenta, tanto os estagiários poderão ser treinados para classificar as imagens no padrão de densidades do BI-RADS, respeitando as particularidades locais, quanto os resultados dos CAD poderão ser comparados. / This thesis presents a computational method that classifies the mammography into the composition of the breast tissue density patterns described in the BI-RADS protocol, intended to help in the early detection of breast cancer, either if this detection happens to be realized by visual analysis or by computerized support. The classification of the mammography in standardized database intends to eliminate issues between mammography awards of distinct professionals and the correct medical conduct to be followed. However, the determination of database only visually, especially in different periods, difficult it\'s to standardize, causing an extremely subjective classification and relatively superficial in consequence of the large inter-and intraobserver variability. The method allows classifying the images independently of the subjective quality of the visual analysis from who organized the database or from the technique of the exposition to X-ray employed. The results were superior of 92% even to database totally distinct. These results were obtained respecting eventual differences of interpretation from several medical groups. Beside the establishment of mammography database with thresholding between the well quantified categories, this methodology will consent to probationers to be trained for classify the images according to the composition of the breast tissue density patterns described in the BI-RADS, respecting its local particularity. Likewise, with this methodology, the results from CAD would be compared.
8

Diagnostic performance of maximum slope: a kinetic parameter obtained from ultrafast dynamic contrast-enhanced magnetic resonance imaging of the breast using k-space weighted image contrast (KWIC) / 乳房領域における高速造影検査法(KWIC)を用いたMRI血流動態パラメータ:Maximum slopeの診断能評価

Ohashi, Akane 23 September 2020 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第22741号 / 医博第4659号 / 新制||医||1046(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 辻川 明孝, 教授 伊達 洋至, 教授 羽賀 博典 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
9

Дигитална мамографија и томосинтеза у детекцији и радиолошкој БИ РАДС категоризацији туморских лезија дојке / Digitalna mamografija i tomosinteza u detekciji i radiološkoj BI RADS kategorizaciji tumorskih lezija dojke / Digital mammography and tomosynthesis in BIRADS lesions characterization

Prvulović Bunović Nataša 28 April 2015 (has links)
<p>Циљ ове студије је да се упореди дијагностичкa значајност 2Д и 2Д+3Д мамографије у детектовању тумора дојке. Испитивали смо 864 дојки у 740 пацијенткиња. Студија је спроведена у току рутинског рада у Центру за имиџинг дијагностику Институту за онкологију Војводине. 2Д + 3Д мамографија су начињене појединачно или у истом акту снимања као комбо опција на Selenia Dimensions апарату произвођача фирме Холоџик. Радиолошки извешатаји су класификовани у категорије 1-5 према АЦР БИ РAДС-у. Патохистолошка верификација је вршена у свих суспектних промена или у току њиховог праћења . Све пацијенткиње са уредним налазом или мамографски уочених бенигних промена су радиолошки праћене најкраће током 2 године. Уочено је 103 малигне лезије у дојкама класификованих као БИ РАДС 4, 5 на дигиталној мамографији и у 22 дојке чије су промене класификоване као БИ РАДС 1-3, током праћења или прегледа дојки помоћу других модалитета. На 2Д + 3Д мамографији малигните је потврђен у 125 дојке од којих је 118 класификовано као БИ РАДС 4,5 и у 7 дојки чује су промене категорисане у БИРАДС 1-3. Постоји статистички значајна разлика у дистрибуцији малигних налаза у односу на подгрупе Студија је показала 20% лажно негативних налаза на 2Д, а 5,6% на 2Д + 3Д модалитету прегледа дојки. Осетљивост у откривању рака у овој студији износи 82,4% на 2Д и 94,4% на 2Д+3Д методи прегледа, док је специфичност 90,5% и 92,0%, респективно. ППВ је већа за 2Д + 3Д технику прегледа , износи 66,7%, као и негативна предиктивна вредност која износи 99,0%. У 172 случаја (19, 9%) налази 2Д мамографије се не уочавају на 3Д техници прегледа и сматрају се последицом структурне или анатомске &bdquo;буке&ldquo;. Већина не -сталних налаза (85%) је класификовано као фокална асиметрија. У овој студији 500 дојки је класификовано према АЦР структури у масне (АЦР 1) или дифузне фибро-гландуларне (АЦР 2), а преосталих 264 је било хетеродензно (АЦР 3) и значајно дензно (АЦР 4). Статистички значајна разлика није показана приликом дистрибуције малигних налаза у поређењу са подгрупама дојки начињеним према њиховој густини - складу са правилима АЦР-а. Укупна тачност теста износи 89,4% за 2Д и 92,4% за 2Д + 3Д мамографију. Предиктивне вредности добијене за 2Д + 3Д мамографију су боље од оних које се односе само на 2Д мамографију, што је резултат њене веће осетљивости и шире могућности карактеризације промена. Варијабилност у интерпретацији налаза међу два радиолога је је ниска, показано је слагање у интершпретавцији евалуираних мамограма у 94.1% случајева.</p> / <p>Cilj ove studije je da se uporedi dijagnostička značajnost 2D i 2D+3D mamografije u detektovanju tumora dojke. Ispitivali smo 864 dojki u 740 pacijentkinja. Studija je sprovedena u toku rutinskog rada u Centru za imidžing dijagnostiku Institutu za onkologiju Vojvodine. 2D + 3D mamografija su načinjene pojedinačno ili u istom aktu snimanja kao kombo opcija na Selenia Dimensions aparatu proizvođača firme Holodžik. Radiološki izvešataji su klasifikovani u kategorije 1-5 prema ACR BI RADS-u. Patohistološka verifikacija je vršena u svih suspektnih promena ili u toku njihovog praćenja . Sve pacijentkinje sa urednim nalazom ili mamografski uočenih benignih promena su radiološki praćene najkraće tokom 2 godine. Uočeno je 103 maligne lezije u dojkama klasifikovanih kao BI RADS 4, 5 na digitalnoj mamografiji i u 22 dojke čije su promene klasifikovane kao BI RADS 1-3, tokom praćenja ili pregleda dojki pomoću drugih modaliteta. Na 2D + 3D mamografiji malignite je potvrđen u 125 dojke od kojih je 118 klasifikovano kao BI RADS 4,5 i u 7 dojki čuje su promene kategorisane u BIRADS 1-3. Postoji statistički značajna razlika u distribuciji malignih nalaza u odnosu na podgrupe Studija je pokazala 20% lažno negativnih nalaza na 2D, a 5,6% na 2D + 3D modalitetu pregleda dojki. Osetljivost u otkrivanju raka u ovoj studiji iznosi 82,4% na 2D i 94,4% na 2D+3D metodi pregleda, dok je specifičnost 90,5% i 92,0%, respektivno. PPV je veća za 2D + 3D tehniku pregleda , iznosi 66,7%, kao i negativna prediktivna vrednost koja iznosi 99,0%. U 172 slučaja (19, 9%) nalazi 2D mamografije se ne uočavaju na 3D tehnici pregleda i smatraju se posledicom strukturne ili anatomske &bdquo;buke&ldquo;. Većina ne -stalnih nalaza (85%) je klasifikovano kao fokalna asimetrija. U ovoj studiji 500 dojki je klasifikovano prema ACR strukturi u masne (ACR 1) ili difuzne fibro-glandularne (ACR 2), a preostalih 264 je bilo heterodenzno (ACR 3) i značajno denzno (ACR 4). Statistički značajna razlika nije pokazana prilikom distribucije malignih nalaza u poređenju sa podgrupama dojki načinjenim prema njihovoj gustini - skladu sa pravilima ACR-a. Ukupna tačnost testa iznosi 89,4% za 2D i 92,4% za 2D + 3D mamografiju. Prediktivne vrednosti dobijene za 2D + 3D mamografiju su bolje od onih koje se odnose samo na 2D mamografiju, što je rezultat njene veće osetljivosti i šire mogućnosti karakterizacije promena. Varijabilnost u interpretaciji nalaza među dva radiologa je je niska, pokazano je slaganje u interšpretavciji evaluiranih mamograma u 94.1% slučajeva.</p> / <p>The aim of this study was to compare diagnostic importance of 2D and 2D+3D diagnostic mammography in breast tumor detection. We evaluated 864 breasts in 740 patients. Study was performed in Diagnostic Imaging Center at Oncology Institute of Vojvodina. 2D+3D mammography were performed during single procedure or via combo option at Selenia Dimensions unit, Hologic, BE. Radiological findings were classified in categories 1-5 according to ACR BIRADS. Pathohistologic verification was obtained in all suspicious findings or after follow up studies. All other patients with mammographic normal findings or benign findings were fallowed up during 2 years period or longer. We detected malignant lesions in 103 breasts classified as BIRADS 4,5 at digital mammography, and in 22 breasts classified as BIRADS 1-3 after followed up or diagnosed by other imaging modalities. At 2D+3D mammography malignancy was confirmed in 125 breasts, 118 classified as BIRADS 4,5 and in 7 breasts classified as BIRADS 1-3. There is statistically significant difference (p&lt;0.001) in distribution of malignant findings compared to the subgroups classified according to 2D mammography. There was 20% false negative findings on 2D, and 5.6% on 2D+3D modality. Sensitivity in cancer detection in this study is 82.4% and 94.4% for 2D and 2D+3D mammography, while specificity is 90.5% and 92.0%, respectively. PPV is higher for 2D+3D technique (66.7%), as well as negative predictive value (99.0%). In 172 cases (19, 9%) 2D mammography findings did not persist on 3D mammography and were considered as structural or anatomical noise. The majority of the non-persistent findings (85%) were classified as asymmetric focal density. In this study 500 breast were classified according to ACR as fatty (ACR 1) or scattered fibroglandular densities (ACR 2), and the remaining 264 had heterogeneously (ACR 3) and extremely dense breasts (ACR 4). Statistically significant difference (p&lt;0.001) was not shown in distribution of malignant findings compared to the subgroups of density structure according to ACR. Overall accuracy of the test was 89.4% and 92.4% for 2D and 2D+3D mammography, respectively. Predictive values obtained in 2D+ 3D mammography are better than those for 2D mammography alone, as a result of its higher sensitivity and better possibility of lesion characterization. Interobserver variability is low, there is an agreement between two radiologist between two radiologic interpretations in 94.1% cases.</p>
10

Studie zur klinischen Wertigkeit des CAD-Systems in der digitalen Vollfeldmammographie in Abhängigkeit von der Erfahrung des Befunders / Computer-assisted Diagnosis in Full-field Digital Mammography-Results in Dependence of Readers Experiences

Angic, Besim Cetin 22 November 2010 (has links)
No description available.

Page generated in 0.0292 seconds