Avaliação do passivo ambiental lixão desativado do município de Lages SC / Evaluation of environmental liabilities off the dump Lages SCMoraes, Caroline Linke 25 February 2014 (has links)
Made available in DSpace on 2016-12-12T20:12:28Z (GMT). No. of bitstreams: 1
PGEF14MA007.pdf: 4559322 bytes, checksum: 55d9751d276f23795d861f70ded2cdbc (MD5)
Previous issue date: 2014-02-25 / The pollution of soil, surface and groundwater caused by solid waste became the focus of studies around the world, given the recognized potential polluter of environmental liabilities
And the large volume of waste generated daily. This study aims to evaluate the environmental liabilities off dump the city of Lages SC. The site in question is located on the left bank of the BR-282 sense Lages / Florianópolis SC, between the coordinates 27º 46 15, 38 S and 50º 15 10, 92 W an area of 48,000 m². the use of this area for waste disposal occurred between the years 1987 and 2005, when it was deactivated. Collection
Of leachate, water, benthic macroinvertebrates and methane for a qualitative and quantitative analysis were performed gas were performed. The methodology used in the sampling of water and leachate followed the guidelines in Standard Methods for the Examination of Water and Wastewater (APHA, 1999). As for macroinvertebrates is followed Technical Bulletin Nº 19 EMBRAPA, methane gas was measured at 1 m above the ground surface to 40 cm below the ground surface. Using the Resolution Nº 257/05 of CONAMA as a reference to evaluate the physico-chemical parameters obtained for water samples and calculated the WQI. In addition, the BMWP index was used for analysis of macroinvertebrates. To evaluate the values of the physicochemical parameters of landfil leachate Resolution Nº 430/11 of CONAMA was used, was there was in the same reference value was used in the 357/05. Also analyzed the decomposition phase in which
Is the landifill and methane analysis used the Annex 11 of Norm 15 as reference. Using as
Reference to Resolution Nº 357/05 of CONAMA, if we take into account the current situation, the stream would be affected by the landfill framed as Class 4, as well as 92,85% of the points listed in the surroundings. According to the WQI, stream analysis, on average, were rated as acceptable, it is noteworthy that the five stream sampling sites were classified as bad and just as good. As BMWP index, the stream presents critical analysis as predominant and considered very polluted water. Taking as reference to Resolution Nº 430/11 of CONAMA, 43,33% of the points of leachate do not meet the same and therefore could not stand being dumped. With regard to the decomposition phase was predominantly in the methanogenic landfill phase. The concentration of methane gas collected at 1m height from the soil surface, both of cells on top of garbage as contour, meet the limits in
Annex 11 for Norm 15, the same does not occur with the points sampled at 40 cm below the soil surface, which do not meet the limit of oxygen and, when considering the lower flammability of methane 44% reach this value / A poluição do solo e das águas superficiais e subterrâneas, provocada por resíduos sólidos urbanos passou a ser motivo de estudos em todo o mundo, dado ao reconhecido potencial poluidor dos passivos ambientais e o grande volume de resíduos gerado diariamente. O presente trabalho visa fazer uma avaliação do passivo ambiental lixão desativado do município de Lages-SC. O local em questão está localizado na margem esquerda da BR-282 sentido Lages/Florianópolis-SC, entre as coordenadas 27º46 15,38 S e 50º15 10,92 W em uma área de 48.000 m2. O uso de tal área para depósito de resíduos ocorreu entre os anos de 1987 e 2005, quando o mesmo foi desativado. Foram realizadas coletas de chorume, água, macroinvertebrados bentônicos e gás metano para que uma análise qualitativa e quantitativa fosse realizada. A metodologia utilizada nas amostragens de água e chorume seguiu as orientações estabelecidas no Standard Methods for the Examination of Water and Wastewater (APHA, 1999). Quanto aos macroinvertebrados bentônicos seguiu-se o Comunicado Técnico No19 da Embrapa; o gás metano foi medido a 1m acima da superfície do solo a 40 cm abaixo da superfície do solo. Utilizou-se a Resolução N° 357/05 do CONAMA como referência para avaliar os parâmetros físico-químicos obtidos para as amostras de água, bem como calculou-se o IQA. Além disso, o índice BMWP foi utilizado para análise dos macroinvertebrados bentônicos. Para avaliar os valores dos parâmetros físico-químicos do chorume a Resolução N° 430/11 do CONAMA foi utilizada, quando não existia valor de referência na mesma utilizou-se a No 357/05.Também analisou-se a fase de decomposição em que se encontra o aterro e para
análise do metano utilizou-se o anexo 11 da Norma Regulamentadora 15 como norteador. Utilizando como referência a Resolução N° 357/05 do CONAMA, se levarmos em consideração a situação atual, o córrego influenciado pelo lixão seria enquadrado como de Classe 4, assim como 92,85% dos pontos coletados no entorno. De acordo com o IQA, o córrego analisado, em média, foi classificado como aceitável; ressaltando-se que no mesmo cinco pontos amostrados foram classificados como ruins e apenas um como bom. Conforme o índice BMWP , o córrego analisado apresenta águas críticas como predominantes, sendo considerado com água muito poluída. Tomando-se como referência a Resolução N° 430/11 do CONAMA, 43,33% dos pontos de chorume não atendem a mesma e portanto não poderiam estar sendo lançados no ambiente. No que se refere a fase de decomposição o lixão estaria predominantemente na fase metanogênica. A concentração de gás metano coletado a 1m de altura a partir da superfície de solo, tanto encima das células de lixo quanto do contorno, atendem os limites do anexo 11 da Norma Regulamentadora 15; o mesmo não ocorre com os pontos amostrados a 40 cm abaixo da superfície do solo, que não atendem ao limite do oxigênio e, ao considerar o limite inferior de inflamabilidade do metano 44% atingem este valor
|
52 |
Lodos ativados com adi??o de carv?o ativado no tratamento combinado de lixiviado de aterro sanit?rio e esgoto dom?stico / Activated sludges with addition of activated carbon in the combined treatment of landfill leachate and domestic sewageDIAS, Albiane Carvalho 23 February 2017 (has links)
Submitted by Jorge Silva (jorgelmsilva@ufrrj.br) on 2017-07-26T18:05:15Z
No. of bitstreams: 1
2017 - Albiane Carvalho Dias.pdf: 1710937 bytes, checksum: 54d2634d67d97d4c119e2aa8507ca99b (MD5) / Made available in DSpace on 2017-07-26T18:05:15Z (GMT). No. of bitstreams: 1
2017 - Albiane Carvalho Dias.pdf: 1710937 bytes, checksum: 54d2634d67d97d4c119e2aa8507ca99b (MD5)
Previous issue date: 2017-02-23 / CAPES / The inappropriate management of leachate can cause negative environmental impacts, in order to compromise the availability and quality of natural resources, reason of to their complex composition and high polluter potential. One of the alternatives for the treatment of landfill leachate is its combined treatment with domestic sewage in sewage treatment plants, although higher proportions of the leachate in the sewage could compromise the efficiency of the process. This study aimed to evaluate the efficiency of the combined treatment of landfill leachate and domestic sewage in biomass and activated carbon systems. For this, were used sequential batch reactors in lab-scale and two types of activated carbon - granular (GAC) and pulverized (PAC). The work consisted of two stages, among them they are: the tests where the reactors were fed with different mixtures of leachate/synthetic sewage (0, 2, 5 e 10%) and concentrations of GAC (0, 2, 4 e 6 g/L) operating with residence times 23h and sludge ages 28 days; and tests where the reactors were fed with a mixture of 5% leachate/sewage; fixed a PAC concentration of 6 g/L and were operated on with differents HRT of 23, 16 and 8 hours and sludge ages of 28, 28, and 17 days, respectively. It has been evaluated, the difference between the two types of carbon regarding COD removal efficiency, in the following configurations: fixing the concentration of carbono (6 g/L) and the percentage of leachate in the feed (5% v/v), for the batch time of 23 h and sludge age of 28 d. For the first step, it was possible to verify that the COD removal efficiency was higher in the reactors containing GAC and biomass when comparedes to the reactor containing only biomass. And along this stage of the experiment it was possible to observe that after the increase of leachate concentration in the feed there was a significant drop in COD removal efficiency. In the evaluation of the PACT? process, it was verified that the reactor with HRT of 23 h was the one that presented the best COD and color removal efficiencies the process, 79 and 44%, respectively. In the comparative tests between the two types of carbon, the PAC system proved to be much more efficient in the removal of COD, presenting an average efficiency of 79% when compared to the GAC system (63%). / O gerenciamento inadequado do lixiviado pode causar impactos ambientais negativos, de forma a comprometer a disponibilidade e qualidade dos recursos naturais, devido sua composi??o complexa e seu elevado potencial poluidor. Uma das alternativas para o tratamento de lixiviado de aterros sanit?rios ? o seu tratamento combinado com esgoto dom?stico em esta??es de tratamento de esgoto, embora propor??es mais elevadas do lixiviado no esgoto possam comprometer a efici?ncia do processo. Este trabalho teve por objetivo avaliar a efici?ncia do tratamento combinado de lixiviado de aterro sanit?rio e esgoto dom?stico em sistemas com biomassa e carv?o ativado. Para isto, foram utilizados reatores em batelada sequencial em escala de laborat?rio e dois tipos de carv?o ativado- granular (CAG) e pulverizado (CAP). O trabalho foi constitu?do de duas etapas, dentre elas est?o: os ensaios onde os reatores foram alimentados com diferentes misturas de lixiviado/esgoto sint?tico (0, 2, 5 e 10%) e concentra??es de CAG (0, 2, 4 e 6 g/L) operando com tempos de resid?ncia de 23 h e idades do lodo de 28 dias; e ensaios onde os reatores foram alimentados com uma mistura de 5% de lixiviado/esgoto, fixado uma concentra??o de CAP de 6 g/L e foram operados com diferentes tempos de resid?ncia de 23, 16 e 8 horas e idades de lodo de 28, 28, e 17 dias, respectivamente. Avaliou-se, ainda, a diferen?a entre os dois tipos de carv?o quanto ? efici?ncia de remo??o de DQO, nas seguintes configura??es: fixando a concentra??o de carv?o (6 g/L) e o percentual de lixiviado na alimenta??o (5% v/v), para o tempo de batelada de 23 h e idade do lodo de 28 d. Para a primeira etapa, foi poss?vel verificar que a efici?ncia de remo??o de DQO foi superior nos reatores contendo CAG e biomassa quando comparados ao reator contendo apenas biomassa. E ao longo desta etapa do experimento foi poss?vel observar que ap?s o aumento da concentra??o de lixiviado na alimenta??o houve queda significativa na efici?ncia de remo??o de DQO. Na avalia??o do processo PACT?, verificou-se que o reator com tempo de resid?ncia de 23 h foi o que apresentou as melhores efici?ncias de remo??o de DQO e cor do processo, 79 e 44%, respectivamente. Nos testes comparativos entre os dois tipos de carv?o, o sistema com CAP mostrou-se muito mais eficiente na remo??o de DQO, apresentando efici?ncia m?dia de 79%, quando comparado ao sistema com CAG (63%).
|
53 |
Simulação de fluxo de água e transporte de solutos na zona não-saturada do solo pelo método de elementos finitos adaptativo / Simulation of water flow and solute transport in the unsaturated zone of the soil by adaptative finite element methodPizarro, Maria de Lourdes Pimentel 02 October 2009 (has links)
Devido aos riscos de contaminação dos recursos naturais solo e água, ao alto custo, ao tempo e ao esforço humano nas investigações de campo, os modelos matemáticos, aliados às técnicas numéricas e aos avanços computacionais, constituem uma ferramenta importante na previsão do deslocamento de solutos, contribuindo assim, para o controle de alterações ambientais. No Brasil, a modelação de fluxo e transporte de solutos na zona não-saturada é voltada, quase que exclusivamente, aos problemas relacionados às atividades agrícolas. Entretanto, tão importante quanto a problemática dos produtos químicos nas atividades agrícolas é a questão de poluição e contaminação do solo e da água por chorume, gerado pelos resíduos sólidos domiciliares. Neste trabalho, é desenvolvido e validado um modelo computacional unidimensional para simulação de fluxo e transporte de solutos na zona não-saturada do solo. O modelo matemático é dado pela equação diferencial parcial não-linear de Richards, que rege o movimento de água no solo, e a equação diferencial parcial linear de advecção-dispersão, do transporte de solutos, acompanhadas das condições iniciais e de contorno. A equação de Richards é dada em função do potencial matricial da água e a equação de transporte de solutos estima a evolução temporal da concentração de solutos no perfil do solo. Devido à dificuldade de se obter soluções analíticas destas equações, são resolvidas numericamente pelo método de elementos finitos. As referidas equações são resolvidas utilizando-se malhas uniformes inicialmente. Com a finalidade de obter simulações mais eficientes, a um custo computacional reduzido, é empregada a adaptatividade com refinamento h na malha de elementos finitos. A função interpolação polinomial utilizada é de grau 2 ou maior que garante a conservação de massa. Na equação de Richards, a derivada temporal é aproximada por um quociente de diferença finita e é aplicado o esquema de Euler explícito e na equação de advecção-dispersão, é aproximada por um quociente de diferença finita, aplicando-se o esquema de Euler implícito, devido à linearidade da equação. O sistema operacional é o Linux Ubuntu 32 bits, o ambiente de programação é o PZ, escrito em linguagem de programação C++. Na validação do modelo, utilizam-se dados disponíveis na literatura. Os resultados são comparados, utilizando-se malhas uniformes e malhas adaptativas com refinamento h. Usando-se as malhas uniformes para o problema de Richards e de transporte de potássio, o tempo de execução é de 22 minutos e a memória utilizada de 6164 Kb. Com as malhas adaptadas, o tempo de execução é de 3 minutos e 27 segundos, consumindo 5876 Kb de memória. Houve, portanto, uma redução de 84,32% no tempo de execução, usando-se malhas adaptativas. A utilização da função interpolação polinomial de grau 2 ou maior e o refinamento h, permitem uma boa concordância do modelo na comparação com soluções disponíveis na literatura. / Due to the risks of contamination of soil and water resources, the high cost, time and human effort in the field investigations, the mathematical models, combined with numerical techniques and computational advances, are important tools in forecasting the movement of solutes thereby contributing to the control of environmental alteration. In Brazil, modeling of flow and solute transport in the unsaturated zone is focused, almost exclusively, on problems related to agricultural activities. However, as important as the problematical of chemicals products in agricultural activities is the issue of pollution and contamination of soil and water by leachate, generated by municipal solid wastes. In this work, an one-dimensional computational model for simulation of flow and solute transport in the unsaturated soil has been developed and validated. The mathematical model is given by the Richards\'s non-linear partial differential equation, which determines the movement of water in the soil, and the advection-dispersion linear partial differential equation, of the solute transport, together with initial and boundary conditions. The Richards equation is a function of the water pressure head and the solute transport equation estimate the temporal evolution of the solutes concentration in the soil profile. Due to the difficulty of obtaining analytical solutions of these equations, they are solved numerically using the finite element method. The governing equations are solved using initially a uniform mesh. In order to obtain more efficient simulations with low computational cost, adaptativity with h refinement on the finite element mesh is implemented. The interpolation function is of degree two or higher, assuring mass conservation. In Richards\' equation, the temporal derivative is approximated by Euler explicit finite difference. For the advection-dispersion equation, due to the linearity of the equation, an implicit finite difference scheme is used. The code is written in the programming language C++ based on the programming environment PZ using operating system Linux Ubuntu 32 bit. Model results are validated in comparison with data available in the literature. The results are evaluated using uniform meshes and with h refinement adaptive mesh. Using the uniform meshes for the problem of Richards and transport of potassium, the running time is 22 minutes and 6164 Kb of memory is used. With the adapted meshes, the execution time is 3 minutes and 27 seconds, consuming 5,876 Kb of memory. Therefore there was a reduction of 84.32% in execution time, using adaptive meshes. The interpolation function with degree two or higher and the h refinement, with reduction of the computation time, showed a good agreement in comparison with the literature.
|
54 |
[en] ANALYSIS AND FORMULATION OF PROCESSES FOR TREATING LEACHATES GENERATED IN URBAN SOLIDS WASTES LANDFILLS / [pt] ANÁLISE E FORMULAÇÃO DE PROCESSOS PARA TRATAMENTO DOS CHORUMES GERADOS EM ATERROS DE RESÍDUOS SÓLIDOS URBANOSGANDHI GIORDANO 06 January 2004 (has links)
[pt] Mediante avaliação experimental comparativa, foi
estabelecido que os processos de tratamento eletrolítico
e
de precipitação química são adequados para
o tratamento primário de chorume gerado em aterro de
resíduo sólido urbano. Foi também comprovado
experimentalmente ser o stripping uma operação indicada
para a remoção da amônia presente no chorume.
O trabalho teve início com a caracterização do chorume
através de parâmetros sanitários convencionais e também
de
análise instrumental visando a determinação das
substâncias
orgânicas presentes. Nesta caracterização foi dada
ênfase ao chorume do aterro metropolitano do Rio de
Janeiro
(Gramacho).
A caracterização do chorume indicou altas concentrações
de
sais dissolvidos, amônia e matéria orgânica,
características de chorume velho. Os resultados são
compatíveis com os obtidos com amostras de chorume
oriundas
de aterros de mesmo porte de outros países. No chorume
bruto a concentração de amônia ficou normalmente cerca de
500 vezes acima do limite de lançamento. A
amônia apresenta alta toxidade aos peixes, o que torna a
sua remoção justificada e necessária. Por outro lado, as
análises instrumentais utilizando a técnica de
cromatografia gasosa com espectrometria de massa (GC/MS),
permitiram a identificação, ainda inédita, de substâncias
orgânicas oriundas da biodegradação e/ou decomposição dos
resíduos sólidos urbanos, bem como de produtos químicos
dispostos no aterro ou contidos em embalagens.
Foi também conduzido um programa experimental, em escala
de
bancada, para avaliar a aplicação dos processos
eletrolíticos e de precipitação química ao
tratamento do chorume. Foram investigados diversos
parâmetros, tais como:adição de produtos químicos,
consumo
de energia, quantidade e características do
lodo gerado e qualidade do chorume tratado em relação a
diversos parâmetros sanitários. O chorume tratado também
foi submetido a análise cromatográfica, de
modo a determinar alterações qualitativas na sua
composição
química durante o tratamento. O processo eletrolítico
mostrou-se bastante indicado para a remoção
de compostos orgânicos do chorume, porém não adequado
para
a remoção de amônia. A precipitação química mostrou-se
boa
para a remoção de orgânicos e propiciadora da remoção de
amônia, sem ser, no entanto, a melhor opção do ponto
de vista de otimização de custos. A melhor solução
encontrada, sob todos os aspectos, consiste na combinação
desses dois processos.
Foi então conduzida uma série de experimentos voltados
para
a remoção da amônia por stripping, após a etapa de
precipitação química com hidróxido de cálcio (cal).
Investigou -se a influência de parâmetros tais como pH e
temperatura na eficiência de remoção de amônia, tendo
sido
obtidas eficiências de remoção da ordem de 90 % nas
condições de pH na faixa de 10 a 12,5 na temperatura
ambiente. Estes resultados experimentais indicaram que os
processos físicoquímicos estudados são a alternativa mais
vantajosa para a remoção das altas concentrações de
nitrogênio amoniacal encontradas no chorume. A remoção
dessas grandes quantidades de N-NH3 também foi vantajosa,
tanto operacional como economicamente, considerando-se a
etapa subseqüente de tratamento biológico. Verificou-se
também que a quantidade de amônia removida do
chorume de Gramacho através do stripping aponta para a
possibilidade de sua recuperação para fins econômicos,
sob
a forma de sulfato de amônio. / [en] Following an experimental examination of available
techniques, it was established that electrolytic treatment
and chemical precipitation are most
adequate for the primary treatment of leachates generated
in municipal solid waste landfills. It was also determined
experimentally that an air stripping operation is
indicated for removal of ammonia present in the leachate.
The initial stages of this present work concerned the
characterization of leachate in accordance with
conventional sanitary parameters, together with
analytically determined organics contents. In making such
characterizations, use was made of the leachate emanating
from the metropolitan landfill of Rio de
Janeiro (Gramacho). This leachate exhibited high
concentrations of dissolved salts, ammonia and organic
material - typical of old established landfills. Such
results are comparable with those obtained from similar
landfills in other countries. The concentration of ammonia
in the raw leachate was frequently at least 500 times the
permissible limit. Ammonia is highly toxic towards fish and
its removal is accordingly justified on these grounds alone.
Furthermore, the analyses were carried out using the
techniques of gas chromatography with mass spectrometry
(GC/MC), which permitted the identification, previously
unreported, of organic substances, originated from the
biodegradation and/or decomposition of municipal solid
wastes, and of the chemical products found in the landfill
itself or in deposited containers.
An experimental programme was, at the same time, conducted
in the laboratory to evaluate the application of the
electrolytic and chemical precipitation
processes for the treatment of leachate. A number of
diverse parameters were investigated, such as: usage of
chemicals, energy consumptions, quantity and
characteristics of sludge generated, and the quality of
treated leachate, in terms of diverse sanitary parameters.
The treated leachate was also submitted to
chromatographic analysis in order to determine changes in
its chemical composition during treatment.
The electrolytic process was shown to be well suited to the
removal of organic materials from the leachate but was not
effective in the removal of ammonia. Chemical precipitation
was found to be a suitable means of removal of
both organics and ammonia, although it does not feature
highly in terms of its cost effectiveness. A better
solution, in the overall sense, is considered to be that
which comprises a combination of these two processes.
A series of experiments was also undertaken designed to
investigate the removal of ammonia by air stripping, after
the chemical precipitation stage with calcium hydroxide.
During these experiments, the influence on the efficiency of
removal of ammonia of parameters such as pH and temperature
was determined.
Removal efficiencies of the order of 90% were obtained at
pH levels between 10 and 12.5, at ambient temperature.
These experimental results indicate that the
physico-chemical processes studied represent the optimum
alternative for removal of high concentrations of
ammoniacal nitrogen encountered in leachate.
The removal of large quantities of N - NH3 is furthermore
considered to be economically attractive when followed by
biological treatment. It was also established that the
quantity of ammonia, which could be removed from the
Gramacho leachate, utilizing the stripping process, is such
as to present economic possibilities for its recovery as
ammonium sulphate.
|
55 |
Simulação de fluxo de água e transporte de solutos na zona não-saturada do solo pelo método de elementos finitos adaptativo / Simulation of water flow and solute transport in the unsaturated zone of the soil by adaptative finite element methodMaria de Lourdes Pimentel Pizarro 02 October 2009 (has links)
Devido aos riscos de contaminação dos recursos naturais solo e água, ao alto custo, ao tempo e ao esforço humano nas investigações de campo, os modelos matemáticos, aliados às técnicas numéricas e aos avanços computacionais, constituem uma ferramenta importante na previsão do deslocamento de solutos, contribuindo assim, para o controle de alterações ambientais. No Brasil, a modelação de fluxo e transporte de solutos na zona não-saturada é voltada, quase que exclusivamente, aos problemas relacionados às atividades agrícolas. Entretanto, tão importante quanto a problemática dos produtos químicos nas atividades agrícolas é a questão de poluição e contaminação do solo e da água por chorume, gerado pelos resíduos sólidos domiciliares. Neste trabalho, é desenvolvido e validado um modelo computacional unidimensional para simulação de fluxo e transporte de solutos na zona não-saturada do solo. O modelo matemático é dado pela equação diferencial parcial não-linear de Richards, que rege o movimento de água no solo, e a equação diferencial parcial linear de advecção-dispersão, do transporte de solutos, acompanhadas das condições iniciais e de contorno. A equação de Richards é dada em função do potencial matricial da água e a equação de transporte de solutos estima a evolução temporal da concentração de solutos no perfil do solo. Devido à dificuldade de se obter soluções analíticas destas equações, são resolvidas numericamente pelo método de elementos finitos. As referidas equações são resolvidas utilizando-se malhas uniformes inicialmente. Com a finalidade de obter simulações mais eficientes, a um custo computacional reduzido, é empregada a adaptatividade com refinamento h na malha de elementos finitos. A função interpolação polinomial utilizada é de grau 2 ou maior que garante a conservação de massa. Na equação de Richards, a derivada temporal é aproximada por um quociente de diferença finita e é aplicado o esquema de Euler explícito e na equação de advecção-dispersão, é aproximada por um quociente de diferença finita, aplicando-se o esquema de Euler implícito, devido à linearidade da equação. O sistema operacional é o Linux Ubuntu 32 bits, o ambiente de programação é o PZ, escrito em linguagem de programação C++. Na validação do modelo, utilizam-se dados disponíveis na literatura. Os resultados são comparados, utilizando-se malhas uniformes e malhas adaptativas com refinamento h. Usando-se as malhas uniformes para o problema de Richards e de transporte de potássio, o tempo de execução é de 22 minutos e a memória utilizada de 6164 Kb. Com as malhas adaptadas, o tempo de execução é de 3 minutos e 27 segundos, consumindo 5876 Kb de memória. Houve, portanto, uma redução de 84,32% no tempo de execução, usando-se malhas adaptativas. A utilização da função interpolação polinomial de grau 2 ou maior e o refinamento h, permitem uma boa concordância do modelo na comparação com soluções disponíveis na literatura. / Due to the risks of contamination of soil and water resources, the high cost, time and human effort in the field investigations, the mathematical models, combined with numerical techniques and computational advances, are important tools in forecasting the movement of solutes thereby contributing to the control of environmental alteration. In Brazil, modeling of flow and solute transport in the unsaturated zone is focused, almost exclusively, on problems related to agricultural activities. However, as important as the problematical of chemicals products in agricultural activities is the issue of pollution and contamination of soil and water by leachate, generated by municipal solid wastes. In this work, an one-dimensional computational model for simulation of flow and solute transport in the unsaturated soil has been developed and validated. The mathematical model is given by the Richards\'s non-linear partial differential equation, which determines the movement of water in the soil, and the advection-dispersion linear partial differential equation, of the solute transport, together with initial and boundary conditions. The Richards equation is a function of the water pressure head and the solute transport equation estimate the temporal evolution of the solutes concentration in the soil profile. Due to the difficulty of obtaining analytical solutions of these equations, they are solved numerically using the finite element method. The governing equations are solved using initially a uniform mesh. In order to obtain more efficient simulations with low computational cost, adaptativity with h refinement on the finite element mesh is implemented. The interpolation function is of degree two or higher, assuring mass conservation. In Richards\' equation, the temporal derivative is approximated by Euler explicit finite difference. For the advection-dispersion equation, due to the linearity of the equation, an implicit finite difference scheme is used. The code is written in the programming language C++ based on the programming environment PZ using operating system Linux Ubuntu 32 bit. Model results are validated in comparison with data available in the literature. The results are evaluated using uniform meshes and with h refinement adaptive mesh. Using the uniform meshes for the problem of Richards and transport of potassium, the running time is 22 minutes and 6164 Kb of memory is used. With the adapted meshes, the execution time is 3 minutes and 27 seconds, consuming 5,876 Kb of memory. Therefore there was a reduction of 84.32% in execution time, using adaptive meshes. The interpolation function with degree two or higher and the h refinement, with reduction of the computation time, showed a good agreement in comparison with the literature.
|