• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 594
  • 355
  • 112
  • 61
  • 50
  • 23
  • 18
  • 9
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1390
  • 616
  • 562
  • 320
  • 207
  • 168
  • 139
  • 139
  • 133
  • 133
  • 130
  • 117
  • 115
  • 109
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
471

Design de vestuário íntimo : o sutiã sob a abordagem de conforto

Kagiyama, Waka January 2011 (has links)
Este trabalho de dissertação de Mestrado em Design da UFRGS (2008-2011) visou a atender algumas exigências das mulheres em relação ao conforto no uso de sutiãs. O processo de design de sutiãs deve compreender não somente as características físicas do sutiã e do corpo humano, mas também as interações entre os sutiãs e as mulheres que os vestem. O ato de vestir sutiãs afeta a fisiologia e a psicologia humana, as quais, por sua vez, influenciam a sensação de conforto e até a saúde das mulheres. Sutiãs brasileiros e japoneses têm distintos aspectos, devido às diferenças nas características culturais, psicológicas e físicas de suas usuárias. Neste trabalho, uma investigação foi conduzida sobre a percepção do próprio corpo e da roupa íntima por jovens universitárias brasileiras e japonesas na faixa etária entre 17 e 29 anos. Questionários online foram aplicados e seus resultados tratados por análises estatísticas para extrair percepções fundamentais das brasileiras e das japonesas. Além disso, medidas foram realizadas nos laboratórios da Kyoto Women’s University no Japão. Seis sutiãs comerciais fabricados no Brasil e no Japão com conceito de conforto foram utilizados como amostras. Dados tridimensionais dos corpos das participantes vestindo sutiãs foram obtidos através de 3D scanners. A pressão exercida pelos sutiãs no corpo foi medida através de sensores de pressão. Estas variáveis foram empregadas para verificar a influência dos materiais e da estrutura dos sutiãs no desempenho geral deles. Um teste sensorial também foi aplicado em forma de um questionário baseado no método do diferencial semântico adaptado para levantar os fatores mais importantes em relação às sensações ao se vestir sutiãs. Todos os resultados das investigações foram considerados para a análise da relação entre desempenho dos sutiãs e a sensação ao vesti-los. Foi observado que as percepções e as sensações das usuárias brasileiras e japonesas são diferentes e devem ser levadas em consideração no processo de design de sutiãs bem sucedidos. Parâmetros-chave foram recomendados para melhorar o desenvolvimento do design de sutiãs com foco no conforto que buscam se adequar às características apontadas pelo público alvo deste trabalho. / This study of dissertation of Master’s degree in Design at UFRGS (2008-2011) aimed at attending some demands of women related to comfort when wearing brassieres. The design process of brassieres must grasp not solely physical characteristics of brassieres and human body, but also interactions between brassieres and women who wear them. Wearing brassieres affects the human physiology and psychology, which in turn influence the sensation of comfort and even women’s health. Brazilian and Japanese brassieres hold different features due to differences in cultural, psychological and physical characteristics of their users. In this work, an investigation was conducted about perception on own body and underwear of young undergraduate Brazilian and Japanese women, in the age group from 17- to- 29-year-old. Online questionnaires were applied and results were treated by statistical analysis in order to extract fundamental perceptions of Brazilians and Japanese. Measurements were carried out at the laboratories of Kyoto Women’s University in Japan. Six commercial brassieres produced in Brazil and Japan with concept of comfort were used as samples. 3D data of participants’ body wearing brassieres were obtained by means of 3D scanners. Clothing pressures exerted by brassieres on body were measured by pressure sensors. These variables were utilized to verify the influence of materials and structure of brassieres on the general performance of brassieres. Sensory test was also applied in form of a questionnaire based on an adapted semantic differential method to find the most important factors related to the sensations felt when wearing brassieres. All results of investigations were considered to analyze the relationship between performance of brassieres and sensation felt. It was found that perception and sensations of Brazilians and Japanese are different and should be taken into account in the design process of successful brassieres. Key parameters were recommended for improving the development of brassieres design with focus on comfort seeking to match the characteristics stressed by the target audience of this study.
472

Avaliação da percepção da sensação térmica em uma sala de controle

Grandi, Mariele Stefani January 2006 (has links)
Este trabalho aborda a avaliação da percepção do conforto térmico em uma sala de controle, tendo como objetivo identificar quais os fatores que influenciam na sensação térmica dos operadores e se esta sensação difere estatisticamente entre os quatro turnos de trabalho. Foram medidas as variáveis ambientais (temperatura do ar, temperatura média radiante, umidade do ar e velocidade do ar), levantadas as variáveis pessoais (vestimenta e taxa metabólica) e aplicados questionários para coletar as sensações térmicas dos operadores a cada 1 hora. A taxa metabólica foi estimada em função da atividade, conforme os valores tabelados pela ASHRAE (2001), mas tal estimação pode apresentar imprecisões devido às diferenças individuais e às condições fisiológicas do ser humano, que são influenciadas pelo ritmo circadiano. O isolamento térmico médio das vestimentas foi de 0,5 a 0,8clo, sendo que os valores mais elevados ocorreram no turno da madrugada. Devido ao controle ambiental térmico da sala, a temperatura média do ar ao longo do dia permaneceu dentro de limites muito próximos. A sensação térmica predominantemente relatada pelos operadores, foi neutra, isto é, nem frio nem calor. Apenas em alguns períodos, principalmente no turno da madrugada, foi relatado desconforto devido ao frio. Não houve diferença significativa entre os resultados de conforto para os diferentes turnos de trabalho, mas o assunto merece estudos mais aprofundados. Os valores de PMV apresentaram baixa correlação estatística com as sensações relatadas pelos operadores, provavelmente em função dos valores da taxa metabólica e do isolamento térmico das vestimentas serem tabelados e não se ajustarem ao ambiente de trabalho. Devido a esta baixa correlação, a Anova não paramétrica de Kruskal-Wallis foi utilizada permitindo identificar que a temperatura do ar, a temperatura média radiante, a umidade do ar e a vestimenta utilizada influenciaram a sensação térmica dos operadores. Tendo em vista que o PMV não predisse a sensação térmica dos usuários, conclui-se que ele não é um bom parâmetro para uso em projetos de ambiente construído. / This present work approachs the evaluation of thermal comfort perception inside a control room, having the specific goal to identify which factors are important to the worker’s thermal sensation and if this sensation differs statistically among the four shifts work. Each environmental parameter (air temperature, mean radiant temperature, relative humidity and air velocity) were measured. The personal variables (clothing insulation and metabolic rate) were evaluated and questionnaires were applied to collect worker’s thermal sensation each hour. The metabolic rate was estimated through the activity, according to the ASHRAE table (2001). This estimative might not be precise due to individual differences and to physiological conditions of the human being, which are influenced by the circadian rhythm. The clothing insulation was 0,5 to 0,8 clo, and the highest values occurred in the early hours of the morning. Owing to the environmental control of the room, the mean air temperature through the day did not have significant changes. The thermal sensation predominantly reported by the workers was neutral, that is, neither cold nor warm. Only in a few periods, especially in the early hours of the morning, was related discomfort because of the cold. There is not a significative difference among the comfort results for the different shifts work, but the topic deserves deeper studies. The PMV values no small statistic correlation with the sensations related by the workers, probably due to the values of the metabolic rate and to the clothing insulation be tabled and were not to adjustable to the work environment. As a result of this weak correlation, the Kruskal-Wallis non parametric Anova was used to identify that air temperature, mean radiant temperature, air relative humidity and clothing insulation influenced the worker’s thermal sensation. Considering that the PMV did not predict the worker’s thermal sensation, the data suggest that the PMV is not a good parameter to be used in projects of buildings.
473

Obtenção e aplicação de microcápsulas de eicosano em espumas de poliuretano visando o conforto térmico em assentos para cadeiras de rodas

Beretta, Elisa Marangon January 2015 (has links)
Espumas de assentos personalizados para cadeiras de rodas se adaptam a anatomia do usuário, no entanto, ao passo que melhoram o posicionamento, podem influenciar negativamente no conforto térmico por aumentar a superfície de contato. O conforto térmico pode ser melhorado com materiais de mudança de fase (PCM), que devem ser aplicados protegidos por um invólucro para impedir seu escape na fase líquida. O invólucro mais comum são as microcápsulas. Assim, o objetivo dessa pesquisa é obter, aplicar e caracterizar microcápsulas com núcleo de material de mudança de fase, mais especificamente o eicosano, em espumas de PU flexível após sua expansão e tecido que recobre o assento, ampliando o efeito termorregulador desse material, reduzindo o tempo de aplicação e desperdício das microcápsulas. Essa é uma pesquisa de natureza aplicada, com técnica de pesquisa de documentação direta através de pesquisa em laboratório, objetivo descritivo e explicativo, com procedimento técnico experimental e abordagem quantitativa. Foram obtidas microcápsulas de eicosano com a variação de diferentes parâmetros e caracterizadas através de MEV, FTIR, granulometria, TGA e DSC. As microcápsulas foram inseridas em amostras de espuma com duas técnicas diferentes (filtração e aerografia) e essas amostras foram analisadas com um termógrafo para verificação do efeito termorregulador gerado. Pode-se concluir que a aerografia proporciona melhor aproveitamento de tempo e de material, ampliando os efeitos térmicos gerados na espuma flexível de PU. Também, o efeito térmico depende não apenas do tipo de microcápsula, mas da quantidade aplicada e sua distribuição pelo material. / Wheelchair custom seats foams can be adapt to the user’s anatomy nonetheless, although it can improve positioning, it influences negatively in thermal comfort as it increases the contact surface. Thermal comfort can be improved with phase change materials (PCM) that must be applied in a casing to prevent its escape in the liquid phase. The most common casing is the microcapsules. The main objective of this research is to obtain, apply and characterize PCM microcapsules, more specifically eicosane, into flexible PU foams after expansion and fabric that recovers the seat, enlarging the thermoregulatory effect of this material, reducing application time and microcapsule waste. It is a study of applied nature, research technique of direct documentation through laboratory investigation, descriptive and explanatory objective, and experimental technical procedure generating quantifiable data. Eicosane microcapsules were obtained varying different parameters and characterizes through SEM, FTIR, granulometry, TGA and DSC. The microcapsules were inserted into foam samples with two different techniques (filtration and aerography). These samples were analyzed through a thermographer to verify its thermoregulatory effect. It can be concluded that aerography has better use of time and material, improving the overall thermal effect in PU foam. Additionally, the thermal effect depends not only in the type of microcapsule, but also in quantity applied and distribution through out the material.
474

Análise do uso de estratégias para a melhoria de eficiência energética e do conforto térmico em edificações com sistemas de automação predial-residencial

Vizzotto, Marcos Rodrigues January 2015 (has links)
O presente trabalho apresenta uma proposta para melhoria da eficiência energética e do conforto térmico em edificações com sistemas de automação predial-residencial. O desenvolvimento da proposta do trabalho foi dividido em três etapas: na primeira etapa foi realizada uma análise inicial do desempenho de uma sala de aula automatizada, com relação ao consumo de energia elétrica do sistema de climatização e o conforto térmico dos usuários, em 4 cenários típicos de uso da sala. Esta análise indicou claras possibilidades de melhorias no sistema de automação, de forma a aumentar o conforto térmico e reduzir-se o consumo de energia. Numa segunda etapa da proposta foi aplicada uma estratégia de alteração dos horários de funcionamento do sistema de climatização com o objetivo de melhorar o conforto térmico dos usuários. Para validação das estratégias propostas foi desenvolvido, utilizando-se o software EnergyPlus, um modelo computacional para simulação da variação de temperatura da sala. Com a análise comparativa de simulações observou-se que alterando o horário de funcionamento do sistema de climatização foi possível manter a sala 100% do tempo na faixa de conforto térmico durante as aulas, porém com um aumento no consumo de energia. Em função disto, numa terceira etapa da proposta foi aplicada uma estratégia para ajustar o valor de setpoint de resfriamento do sistema de climatização integrado ao sistema de automação da sala com o objetivo de melhorar a eficiência energética. O algoritmo foi inicialmente desenvolvido com o software Matlab e foi co-simulado com o modelo computacional utilizando a ferramenta MLE+. Com a análise comparativa de simulações e co-simulações observou-se que houve uma redução no consumo de energia de cerca de17% na sala numa comparação com os cenários validados na primeira etapa. Os conceitos desenvolvidos foram então aplicados no projeto de uma nova edificação, no qual uma redução no consumo de energia em torno de 6%. / The present paper presents a proposal of improvement of energy efficiency and thermal comfort in buildings with home and building automation. The development of the proposal of the paper was divided into three stages: At the first stage it was realized an initial analysis of the performance of an automated room in relation to the consumption of electrical energy by the air conditioning system and the thermal comfort of the users in four typical scenarios of the room use. This analysis indicated clear possibilities of improvement on the automation system in terms of improving thermal comfort and decreasing energy consumption. At the second stage of the proposal it was applied a strategy of alteration of the operation times of the air conditioning system with the objective of improving the thermal comfort of the users. To validate the strategies proposed it was developed, using the EnergyPlus software, a computational model to simulate the variations in temperature in the room. With the comparative analysis of the simulations it was observed that altering the operation times of the air conditioning system it was possible to maintain the room in the thermal comfort zone 100% of the time, however, with an increase in energy consumption. Therefore, at the third stage of the proposal it was applied a strategy to adjust the cooling set point of the air conditioning system integrated to the automation system with the objective of improving energy efficiency. The algorithm was developed initially with the Matlab software and it was co-simulated with the computational model utilizing the MLE+ tool. With the comparative analysis of simulations and co-simulations it was observed that there was a reduction of around 17% in the consumption of energy in the room compared with the scenarios validated at the first stage. The concepts developed were then applied on the project of a new building, in which the reduction of energy consumption was around 6%.
475

Efeitos da carga e duração do exercício sobre o conforto e os parâmetros biomecânicos de contato com o selim em ciclistas / Effects of load and duration exercise on comfort and biomechanics parameters of saddle related contact in cyclists

Dagnese, Frederico January 2011 (has links)
O objetivo deste estudo foi analisar os efeitos da carga de trabalho e do tempo de pedalada sobre a área, força, pressão de contato e o conforto no selim e as relações dos hábitos de vida e características da prática esportiva com a função erétil em ciclistas. Quinze ciclistas recreacionais (CR) e 15 amadores competitivos (CC) do sexo masculino foram avaliados antropometricamente e responderam a questionários relacionados à prática esportiva, aos hábitos de vida e ao índice internacional da função erétil (IIEF). Eles completaram os protocolos de ciclismo que consistiram (1) no ajuste do posicionamento corporal sobre a bicicleta (PAP), (2) protocolo de carga incremental (PCI) para determinação da potência máxima (PM), (3) protocolo de carga variável (PCV) e (4) protocolo de carga constante (PCC). Durante o PCV e PCC foi monitorada a área, força e pressão de contato no selim. No PCC, além destas, foi monitorado o grau de desconforto no selim. Os dados foram descritos na forma de média e desvio padrão considerando nível de significância de a=0,05. Os resultados demonstraram que as diferenças antropométricas e de desempenho entre os grupos foram diferentes, corroborando os diferentes níveis de condicionamento procurados. Foi observada correlação positiva e moderada entre o perímetro de quadril com a área de contato com o selim. Não houve diferença entre os grupos quando comparadas a área, força e pressão de contato para o PCV e PCC, sem efeito também do tempo de pedalada. As diferenças ocorreram nas análises intra-grupos. CR, em resposta a alterações na cadência de pedalada, não tem alterada a área, força e pressão de contato com o selim, sendo observado um efeito contrário sobre as mesmas variáveis quando alterada a potência de pedalada. CC, embora sem mudanças sobre a área de contato, tem modificada a força e pressão de contato em resposta tanto a alterações na cadência quanto potência de pedalada. O aumento da cadência e da potência de pedalada acarreta aumento e diminuição, respectivamente, da área, força e pressão de contato. CC parecem ser mais tolerantes ao desconforto durante o PCC. Os grupos não foram diferentes quando comparados os escores relacionados ao IIEF. Portanto, CC tem alterados de maneira mais destacada a área, força e pressão de contato com o selim em resposta a diferentes cargas de trabalho e são mais tolerantes ao desconforto perineal ao longo do tempo, indicativos de uma maior “flutuação” da pelve sobre o selim. Apesar das diferenças que caracterizam a prática de cada grupo, ciclistas recreacionais e competitivos possuem função erétil normal e semelhante. / This study aimed at assessment of exercise load and duration effects on saddle contact area, reaction force, pressure and comfort and its relationships with daily life habits and training characteristic that may underlie erectile dysfunction among cyclists. Fifteen recreational cyclists (CR) and 15 amateur competitive male (CC) athletes performed the trials. They were first tested for anthropometric characteristics and anamneses related to sport practice, life habits and international index of erectly dysfunction. All participants completed cycling protocols for (1) bike fit, (2) incremental maximal test to determine maximal power output, (3) variable power test (PCV) and (4) constant load test (PCC). Saddle area, reaction force, contact pressure and discomfort level were assessed during PCV and PCC. Data were presented for mean and standard-deviation for significance level of 0.05. The results indicated group differences for anthropometric and performance variables, which may results from different level of physical conditioning between groups. There was positive and moderated correlation between hip circumference and saddle contact area. No difference was observed between groups for area, force and pressure during PCV and PCC, as well any effect of exercise duration was observed. Significant differences were observed within-groups. CR did not altered saddle area, force and pressure when pedaling cadence was changed. In other hand, these variables were significantly affected by exercise load, which suggest that power output rather than pedaling cadence affect saddle pressure in CR. For CC, contact area unchanged, whereas force and pressure were influenced by changes in both pedaling cadence and power output. For this group, increase of cadence or power leaded to higher and lower saddle area, force and pressure, respectively. CC were more tolerant for discomforts while pedaling. There were no differences regarding scores related to erectile dysfunction that was normal between groups. In conclusion, CC present changes in saddle area, force and pressure when exercise load was changed. They also were more tolerant to perineal discomfort during prolonged cycling. Despite of differences in saddle pressure variables between groups, recreational and competitive cyclists had similar and normal erectile function.
476

Otimização de parâmetros concentrados de suspensão para conforto e segurança veicular / Optimization of lumped parameters of suspension for vehicle comfort and safety

Drehmer, Luis Roberto Centeno January 2012 (has links)
O presente trabalho avalia a otimização de parâmetros concentrados de suspensão em veículos e considera a importância deste processo para minimizar a aceleração vertical rms transmitida para garantir conforto e segurança ao motorista. Dessa forma, o trabalho objetiva desenvolver uma modelagem capaz de representar o veículo completo para então otimizar os parâmetros de rigidez e amortecimento no domínio da frequência e identificar, em torno do ponto ótimo, quais desses parâmetros mais influenciam nessa minimização. Para atingir esses objetivos, dois modelos veiculares (com dois e oito graus de liberdade respectivamente) são propostos conforme as orientações das normas BS 6841 (1987), ISO 8608 (1995) e ISO 2631 (1997). Os modelos são analisados linearmente e otimizados por um algoritmo heurístico de enxame de partículas. Finalmente, os resultados de rigidez e amortecimento da suspensão são obtidos e reduzem em até 35,3% a aceleração vertical rms transmitida ao motorista. Por meio de uma análise de sensibilidade, as variáveis de projeto que mais contribuem para essa redução são identificadas. / The present work evaluates the optimization of lumped parameters of suspension on vehicles and considers the importance of this process to minimize the rms vertical acceleration transmitted to ensure comfort and safety to the driver. Thus, this work aims to develop a model able to represent the whole vehicle and, then, optimize the parameters of stiffness and damping in the frequency domain and identify, around the optimal point, those parameters which most influence in this minimization. To achieve these goals, two vehicle models (with two and eight degrees of freedom respectively) are proposed according to the guidelines of the standards BS 6841 (1987), ISO 8608 (1995) and ISO 2631 (1997). The models are linearly analyzed and optimized by a heuristic algorithm of particle swarm. Finally, the results of stiffness and damping of suspension are obtained and reduces up to 35,3% of rms vertical acceleration transmitted to the driver. Through a sensitivity analysis, the design variables that most contribute to this reduction are identified.
477

Caracterização de ambientes internos da região central de São Carlos/SP: material particulado e poluição sonora / Characterization of internal environments of the region central Sao Carlos/SP: particulate material and noise

Elaine Schornobay 25 May 2012 (has links)
Este trabalho teve como objetivo avaliar a qualidade ambiental interna de lojas da região central na cidade de São Carlos/SP. Foram monitorados os seguintes parâmetros: concentração e análise química de MP10 e de MP2,5, \'CO IND.2\', níveis de ruído, temperatura e umidade relativa do ar. A coleta de dados foi realizada de maneira simultânea em ambientes internos e externos de quatro lojas do centro da cidade por um período de oito horas diárias, das 9 h às 17 h. Dois pontos estavam localizados de frente para vias de grande circulação de veículos e dois no calçadão da cidade (sem trânsito de veículos). Os valores de concentração, tanto de MP10 como de MP2,5, se apresentaram, na maior parte dos dias de coleta, com os valores internos superiores aos externos. Para o período chuvoso, em que foi realizado o maior número de coletas, os valores de concentração não ultrapassaram os limites estabelecidos pela OMS, de 25 \'mü\'g/\'M POT.3\' para o MP2,5 e de 50 \'mü\'g/\'M POT.3\' para o MP10. Quanto à análise química, foi observado que não há diferenças significativas entre os ambientes interno e externo. Sendo que, em ambos os ambientes, foram encontrados Si, S, Ca, Fe, Al, K e Cu, elementos comumente observados em áreas urbanas. Em relação ao \'CO IND.2\', o seu monitoramento não se mostrou relevante, já que todos os ambientes monitorados realizavam trocas de ar com o ambiente externo de forma natural, dessa forma a concentração não atingiu valores preocupantes. Os níveis de poluição sonora monitorados no ambiente externo foram superiores aos do ambiente interno em todos os dias monitorados. Os pontos de monitoramento que ficavam direcionados para as vias de circulação de veículos apresentaram valores superiores aos encontrados no calçadão da cidade. Em todos os dias monitorados, os valores de ruído dos ambientes interno e externo não apresentaram acordo com o padrão estabelecido pela NBR 10.151/2.000, de 50 dB(A) e 60 dB(A), respectivamente. Sendo que os valores externos ficaram entre 61 dB(A) e 66,8 dB(A) e, para o ambiente interno, os valores variaram de 53,9 dB(A) a 63,6 dB(A). A temperatura e a umidade relativa do ar apresentaram variações ao longo do dia e, de acordo com a RE/ANVISA nº 09/2003 e o índice HI, a maioria dos dias monitorados sugere sensação de desconforto térmico aos ocupantes desses locais. / This study aimed to evaluate the indoor environmental quality of shops in the central region in São Carlos/SP. The following parameters were monitored: the concentration and chemical analysis of MP10 and MP2,5, \'CO IND.2\', noise levels, temperature and relative humidity. Data collection was performed simultaneously in internal and eternal environments of four stores in the center of town for period of eight hours daily, from 9 am to 5 pm. Two points were located in front of large circulation routes for vehicles and two on the sidewalk of the city (no vehicle traffic). The values concentration both PM10 and PM2,5 are presented, in most days of collection, with the internal values higher than the outside. For the rainy season, which was held in the greatest number of samples, the concentration values did not exceed the limits set by OMS of 25 \'mü\'g/\'M POT.3\' for MP2,5 and 50 \'mü\'g/\'M POT.3\' for MP10. In the chemical analyses, it was not observed significant differences between the internal and external environments, since in both environments were found Si, S, Ca, Fe, Al, Cu and K, elements commonly seen in urban areas. In relation to the \'CO IND.2\' monitoring was not relevant, since all monitored environments performed ais exchanges with the external environment in a natural way, producing values concentration not concern. The noise levels monitored in the external environment were superior to the internal environment every day. The monitoring points directed to the traffic routes of vehicles had higher values than those found on the sidewalk of the city. On each day the monitored noise vaues of the internal and external environments not presented inside of the standard established by NRB 10.151/2000 of 50 dB(A) e 60 dB(A), respectively, since external values were between 61 dB(A) and 66,8 dB(A), and the internal environment values ranged from 53,9 dB(A) and 63,6 dB(A). The temperature and relative humidity showed variations thoughout the day, and according to RE/ANVISA nº 09/2003 and the index HI, most of the days monitored suggests thermal discomfort to the occupants of these places.
478

Parâmetros fisiológicos em bovinos leiteiros submetidos ao estresse térmico / Physiological parameters in dairy cattle applied thermal stress

Dalcin, Vanessa Calderaro January 2013 (has links)
A seleção para produção de leite vem aumentando a suscetibilidade de vacas leiteiras ao estresse térmico, principalmente em raças europeias em regiões tropicais e sub-tropicais. Cerca de 95% do rebanho leiteiro no Brasil é composto por animais mestiços. O objetivo deste trabalho, conduzido no campo experimental José Henrique Bruschi da Embrapa Gado de Leite, em Coronel Pacheco – MG, durante o mês de março de 2013, foi investigar alterações nos parâmetros fisiológicos de vacas leiteiras que identifiquem com maior fidedignidade o estresse calórico. Foram realizadas coletas de sangue para análise do hematócrito (Ht), contagem de eritrócitos (ERI) e contagem de hemoglobina (HEMO), além do registro da temperatura retal (TR), da frequência cardíaca (FC), da frequência respiratória (FR), do escore de ofegação (EO) em 38 fêmeas bovinas em lactação, divididas conforme o grupo genético em ½, ¾ e puras, durante seis dias nos turnos da manhã e da tarde. Os dados foram submetidos à análise da variância considerando os efeitos de grupo genético, dias, turnos e suas interações, com medidas repetidas no tempo e regressão “broken-line”. Houve efeito significativo para a interação grupo genético*dia*turno para TR, FC, FR e EO. Os valores de TR, FC, FR e EO do grupo de vacas puras HO foram maiores em relação ao grupo ¾ e esse em relação ao grupo ½. No grupo de vacas puras, as variáveis fisiológicas aumentaram linearmente com o Índice de Temperatura e Umidade (ITU), sem apresentar inflexão. O ponto de inflexão das curvas de variáveis fisiológicas ocorreu num valor de ITU mais alto para o grupo ½ em relação aos demais. Os valores de Ht e HEMO foram distintos entre os grupos genéticos, mas não variaram com o ITU, mostrando que o estresse provocado não foi suficiente para alterar os parâmetros hematológicos medidos. A média de ITU durante o turno da manhã foi de 74, quando 70, 43 e 13% das vacas puras, ¾ e ½, respectivamente, se apresentavam com a FR acima dos padrões de referência. A FR foi o melhor indicativo do estresse térmico e seu valor crítico foi de 140mov/min para as vacas Girolando e 168 mov/min para a raça Holandesa. Vacas da raça Holandesa são mais sensíveis ao estresse térmico do que cruzas Holandês-Zebuíno. / Selection for milk production has increased the susceptibility of dairy cows to heat stress, especially in European breeds reared in tropical and sub - tropical conditions. About 95% of dairy cattle in Brazil are crossbred animals. This study, conducted in the Embrapa Dairy Cattle José Henrique Bruschi experimental station, Coronel Pacheco - MG, was used to investigate changes in the physiological parameters of dairy cows to identify heat stress with greater reliability. Blood samples were collected for analysis of hematocrit (Ht), erythrocyte count (ERI) and hemoglobin count (HEMO), in addition to recording the rectal temperature (RT), heart rate (HR), respiratory rate (RR), panting score (PS) in 38 lactating cows. These varied according to genetic group (½, ¾ and pure bred Holstein (HO)), anda data was collected for six days in the morning and afternoon. Data were subjected to analysis of variance considering the effects of genetic group, days, time of day and their interactions with repeated measures and broken-line regression. Significant effects were found for the interaction between genetic group*day*time of day for RT, HR, RR and PS. These values were higher for pure HO cows were higher than in ¾ and ½ groups. In the HO group, physiological variables increased linearly with the Temperature Humidity Index, without presenting inflection in the regression. The inflection point occurred at a higher ITU highest value for the ½ group compared with the other groups. Ht and HEMO were different among genetic groups and did not vary with the ITU, showing that stress caused was not sufficient to alter the hematological parameters measured. The average THI during the morning shift was 74, when 70, 43 and 13 % of pure HO, ¾ and ½, respectively, presented FR above the standard. The FR was the best indicator of heat stress and its critical value was 140mov/min for Gir cows and 168 mov / min for Holsteins. Holstein cows are more sensitive to heat stress than crossbred Holstein- Zebu.
479

Comportamento térmico de coberturas de fibrocimento em Campinas, SP: aplicação de técnicas passivas / Thermal behavior of fiber-cement roofing in Campinas, SP: application of passive cooling

Teixeira, Carla Fernanda Barbosa 07 1900 (has links)
O Brasil possui a maior parte de suas terras em clima tropical. Sendo a cobertura o elemento construtivo mais exposto à radiação solar direta, toma-se um desafio aos pesquisadores e projetistas, atenuar as temperaturas nas coberturas das edificações e contribuir para o uso racional de energia. O objetivo desta pesquisa é monitorar o desempenho térmico de coberturas de fibrocimento em_ células-teste na cidade de Campinas, SP, com aplicação de técnicas passivas de resmamento. Utilizaram-se quatro células-teste: uma célula-teste de referência, e outras três com os sistemas: evaporativo, radiante e reflexivo, respectivamente, e monitoramento das temperaturas superficiais internas das telhas (TT' s) e temperaturas do ar dos áticos (T AA' s), no período de 21 de janeiro a 9 de fevereiro de 2006. Para o sistema de resmamento evaporativo foram utilizados ciclos de aspersão com diferentes intervalos no período todo. Entre as técnicas monitoradas, o melhor comportamento térmico foi verificado no 2° período (de 26 a 30/jan com aspersão contínua) na temperatura da superficie interna da telha do sistema evaporativo (TTevap = 23,2°C) apresentando um decréscimo de 1,3°C em relação a célulateste de referência e um acréscimo de 0,1 °C em relação as médias da temperatura do ar para o período. Nas médias da temperatura do ar dos áticos, o 2° período apresentou os menores valores para os sistemas: reflexivo (TAArefl =23,4°C) e evaporativo (TAAevap = 23,5°C), apresentando uma atenuação de 0,5°C e 0,4°C em relação a célula de referência respectivamente, além de uma elevação de 0,3°C em relação as médias da temperatura do ar externo. Os resultados, analisados através de tratamento estatístico, demonstram a viabilidade do uso do sistema evaporativo em condições climáticas de elevada umidade relativa do ar, contribuindo para atenuar os efeitos das hostilidades climáticas em coberturas das edificações._________________________________________________________________________________________ ABSTRACT: In Brazil, the tropical climate is predominant in most of regions. Roofing is the building component with the highest exposition to direct solar radiation. The challenge for researchers and designers is to achieve cornfort in the built environrnent and to contribute to energy saving, proposing roofing systems with good thermal insulation, and consequently lesser internal surface temperatures. The objective of this research is to monitor the thermal behavior of fiber-cement roofing and to present a discussion about the results obtained in cell-tests in the city of Campinas, SP, through passive cooling techniques. Four cell-tests were used: one cell-test was adopted as reference, and the other three were analyzed with evaporative, radiative and reflective systems, respectively. The evaporative system was tested with different aspersion cycles through spraying systems and intervals. The monitored parameters were the internal surface temperatures of the roofing tiles (TT s) and attic air temperatures (TAA's) in the period of January 21st to February 9th of2006. Among the monitored passive techniques, the best thermal behavior was observed in the 2nd period (iTom January 26th to 30th, corresponding to continue spraying), related to the internal surface temperature with the evaporative system (TTevap = 23,2°C). A reduction of 1,3°C was observed, as compared to the reference test-cell and and an increase of 0,1 °C in comparison with the average air temperature. In relation to the average of attic air temperature, the 2nd period presented the lowest temperature for reflexive system (T AArefl = 23,4°C) and evaporative system (TAAevap = 23,5°C); a reduction of 0,5°C and 0,4°C in relation of the reference test-cell respectively was observed; also, it showed an increase of 0,3°C as compared with air temperature. The results presented through statistical analyses demonstrated that the use of the evaporative system in climatic conditions with high relative humidity is viable, contributing, therefore, to attenuate the effects of climatic hostilities in the roofing buildings.
480

Índices de conforto térmico e adaptabilidade de fêmeas bubalinas em pastejo no Agreste de Pernambuco

COSTA, Lígia Alexandrina Barros da 28 February 2007 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-04-26T15:36:43Z No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) / Made available in DSpace on 2017-04-26T15:36:43Z (GMT). No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) Previous issue date: 2007-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objectives of this work were to determine the best indexes of thermal comfort for buffaloes and to estimate the upper critical levels of these indexes, based on the physiologic parameters. The experiment was carried from february to april at agreste region of the Pernambuco state. Physiologic parameters as rectal temperature (Tr), breathing frequency (Fr) and skin temperature (Tp) were measured thrice to every week in the periods of the morning and afternoon. Sweating rate (Tsud) was measured in the afternoon, once to every week. Correlation and regression analysis were made using data obtained from ten buffaloes: five heifers and five pregnant buffaloes cows. The results showed that Fr was better than rectal temperature (Tr) and sweating rate (Tsud) as an indicator of heat stress for pregnant bufalloes cows. ITGU was better than ITU, based on Fr. Based on Tr the estimated upper critical levels of temperature-humidity index (ITU) and black globe temperature and humidity index (ITGU) were 79,5 and 89,1, respectively, for the heifers and based on breathing frequency those estimated critical levels were, respectively, 77 and 83. Based on Fr the estimated critical values of ITU and ITGU were 79 and 81, respectively, for the pregnant buffaloes cows. / O objetivo deste trabalho foi determinar os melhores índices de conforto térmico para bubalinos estimando seus valores críticos, baseando-se nos parâmetros fisiológicos. O experimento foi conduzido de fevereiro a abril na região agreste de Pernambuco. Os parâmetros fisiológicos temperatura retal (Tr), freqüência respiratória (Fr) e temperatura de pele (Tp) foram avaliados três vezes por semana nos períodos da manhã e da tarde e a taxa de sudação (Tsud) foi mensurada apenas à tarde, uma vez a cada semana. As medidas para análise de correlação entre as variáveis e regressão foram obtidas de dez animais: cinco novilhas e cinco búfalas em gestação. Os resultados obtidos evidenciaram, nas búfalas em gestação, que Fr foi o melhor indicador de estresse térmico que temperatura retal (Tr) e taxa de sudação (Tsud). O ITGU revelou ser o melhor índice que o ITU, baseando-se na Fr. Com base na Tr foram estimados valores críticos de índice de temperatura e umidade (ITU) e índice de temperatura de globo e umidade (ITGU) iguais a 79,5 e 89,1, respectivamente, para as novilhas. Baseando-se na Fr esses valores foram, respectivamente, 77 e 83. Para as búfalas, considerando a Fr, os valores críticos de ITU e ITGU foram 79 e 81, respectivamente.

Page generated in 0.0337 seconds