• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimisation des performances de membranes polymériques spiralées pour la séparation des caséines du lait par microfiltration

Mercier-Bouchard, Dany January 2017 (has links)
La microfiltration (MF) du lait écrémé permet de séparer les caséines (CN) des protéines sériques (PS) pour la production d’ingrédients laitiers. Réalisée majoritairement à l’aide de membranes céramiques à gradient de perméabilité (MCGP), peu d’études s’intéressent à l’utilisation de membranes polymériques spiralées (MPS). Ainsi, ce projet avait pour objectifs de caractériser les performances hydrauliques et séparatives de MPS et de quantifier leur encrassement et consommation énergétique. La MF a été réalisée à 50°C en recirculation totale avec des MPS de diamètre de pores (DP) de 0,1 et 0,2 μm. Il a été démontré que bien que les flux de perméation soient similaires, des pertes en CN sont observées dans le perméat avec la MPS 0,2 μm. Ainsi, la MPS 0,1 μm a été sélectionnée pour des essais de concentration-diafiltration jusqu’à un facteur de concentration de 3.0X afin de comparer les résultats à ceux d’une MCGP. Il a été démontré que la MPS 0,1 µm générait des flux de perméation 3,5 fois inférieurs que la MCGP, mais permettait de retenir davantage de PS tout en étant 5 fois moins énergivore. Suite à ces résultats, les performances de la MPS 0,1 µm ont été comparées à celles d’une membrane d’ultrafiltration (UF) au seuil de coupure de 10 kDa. Il a été démontré que les flux de perméation de la MPS 0,1 μm étaient supérieurs à ceux de la membrane d’UF et que la rétention des protéines totales est relativement similaire. Par conséquent, l’utilisation de la MPS 0,1 µm s’avère intéressante pour la concentration des CN, tout en permettant une sélectivité similaire des protéines et des performances hydrauliques supérieures par rapport à la membrane d’UF (10 kDa). Ces résultats permettent aux industriels d’effectuer un choix technologique en MF entre les MPS et les MCGP, mais ouvre également la possibilité de substituer l’UF 10 kDa par la MF 0,1 µm pour la préparation de concentrés protéiques pour la fromagerie. / Microfiltration (MF) of skim milk makes it possible to separate the caseins (CN) from the serum proteins (SP) for the production of dairy ingredients. Generally performed with graded-permeability membranes (CGP), few studies have focused on the use of polymeric spiral-wound (PSW) membranes. The objective of this project was to characterize the hydraulic and separative performances of PSW and to quantify their fouling and energy consumption. The MF was carried out at 50°C in total recirculation mode with PSW with a pore diameter (DP) of 0.1 and 0.2 μm. It has been shown even if permeate fluxes are similar, a drastic CN loss was observed in the permeate during MF with PSW membranes of 0.2 μm DP. Thus, 0.1-μm PSW was selected for concentration-diafiltration steps up to a concentration factor of 3.0X in order to compare the results with that of a MCGP. It has been demonstrated that 0.1-μm PSW had permeation fluxes 3.5 times lower than CGP but increased rejection of SP while consuming 5 times less energy. Following these results, the performances of the 0.1 μm MPS were compared with those of an ultrafiltration membrane (UF) with a cutoff threshold of 10 kDa. It has been demonstrated that the permeation fluxes of the 0.1-μm MPS are greater than those of the UF membrane and that the retention of the total proteins is relatively similar. Following these results, the performances of the 0.1-μm PSW were compared with those of a 10 kDa ultrafiltration membrane (UF), demonstrating that permeate fluxes of the 0.1-μm PSW were higher compared to the UF membrane while total protein rejection was relatively similar. Consequently, the use of 0.1 μm MPS proves to be advantageous for CN concentration, while allowing a similar selectivity of the proteins and higher hydraulic performances compared to the UF membrane (10 kDa). These results enable manufacturers to make a technological choice in MF between MPS and MCGP, but also opens the possibility to substitute the 10 kDa UF by the 0.1 μm MF in the preparation of milk protein concentrates for cheese milk standardisation.

Page generated in 0.0792 seconds