• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 3
  • 1
  • 1
  • Tagged with
  • 26
  • 26
  • 26
  • 19
  • 19
  • 14
  • 13
  • 11
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização venosa central em crianças internadas em Unidades de Terapia Intensiva pediátrica /

Paiva, Bianca Sakamoto Ribeiro. January 2005 (has links)
Orientador: José Roberto Fioretto / Resumo: A cateterização venosa central é procedimento indispensável para monitorização e tratamento de crianças internadas em unidades de tratamento intensivo. Apesar de disseminada, a utilização de cateteres venosos centrais (CVCs) não é destituída de complicações no momento da inserção e durante sua manutenção. Os objetivos do estudo foram: identificar e quantificar as complicações da cateterização venosa central em crianças internadas em Unidade de Terapia Intensiva Pediátrica (UTIP); identificar os fatores de risco para complicações de inserção e de manutenção e avaliar a necessidade do emprego de medidas de prevenção de complicações e, se necessário, propor modificação das normas e rotinas dos cuidados de enfermagem vigentes. Analisou-se prospectivamente todas as crianças e adolescentes (1 mês a 18 anos de idade) internados na UTIP no período de um ano e que foram submetidos a punção venosa central, no ambiente da unidade. No período, 120 CVCs foram inseridos em 83 crianças. Os residentes (R3) inseriram 84,2% dos CVCs e não houve correlação entre complicações de inserção e manutenção e o profissional que realizou o procedimento.A taxa de sucesso de punção foi alta. A veia mais puncionada foi a jugular interna (79,2%), observando-se que sete tentativas de punção foram mal sucedidas (5,8%). As complicações de inserção mais freqüentes foram mal posicionamento do cateter (14,1%) e punção arterial (10,9%). Mais de três tentativas de punção foi significante para o aparecimento de intercorrências de inserção dos CVCs (p=0,004). Quanto as complicações de manutenção, houve correlação significante para troca do cateter realizada com fio guia (p=0,008), utilização de ventilação mecânica (p=0,025) e tempo de permanência do cateter por mais de sete dias (p=0,001). Sinais flogísticos ocorreram em 68,2% dos locais de inserção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Central Venous Catheters (CVCs) are considered indispensable in the current medical practice. The aim of this study was to identify and to analyze the complications of the venous catheterization in children admitted in the Pediatric Intensive Care Unit (PICU) - UNESP, and to identify the risk factors for insertion and maintenance of CVCs. Also we aim to evaluate the necessity from prevention measures of complications and if it is necessary to change nursing care routine. During one year we analyzed prospectively 120 CVCs inserted in 83 children aged between 1 month and 18 years. Residents (R3) inserted 84.2% CVCs and no differences were observed between insertion and maintenance complications and the professional responsible for the procedure. Success punction rate was level. Internal jugular vein was the most punctioned vein (79,2%), and only 7 attempts failure (5,8%). Insertion complications more frequent were catheter bad positioned (14,1%) and arterial punction (10,9%). More than three attempts were statistical significant to insertion complication (p=0.004) and CVCs changed with guidewire were significant (p=0.008) to maintenance complications, as well as mechanical ventilation and indwelling time more than 7 days. Local infection was diagnosed in 68,2% and there were two cases of bloodstream-catheter-related infection. Constant observation of the nursing techniques, have showed that 82.3% of the nursing personal did not wash their hands before dressing, verifying association between no washing hands and appearing local infection catheter (p=0,005). Coagulase-negative Staphylococcus was the most common microorganism isolated from the catheters. Results aim the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters. Results make clear the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters. / Mestre
2

Central venous access devices in patients with haematological malignancies : care, complications and home treatment /

Johansson, Eva, January 2002 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2003. / Härtill 5 uppsatser.
3

Caracterização venosa central em crianças internadas em Unidades de Terapia Intensiva pediátrica

Paiva, Bianca Sakamoto Ribeiro [UNESP] 16 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-16Bitstream added on 2014-06-13T20:17:42Z : No. of bitstreams: 1 paiva_bsr_me_botfm.pdf: 258888 bytes, checksum: c116621cfb93317f8c7ac2431a63ec8f (MD5) / A cateterização venosa central é procedimento indispensável para monitorização e tratamento de crianças internadas em unidades de tratamento intensivo. Apesar de disseminada, a utilização de cateteres venosos centrais (CVCs) não é destituída de complicações no momento da inserção e durante sua manutenção. Os objetivos do estudo foram: identificar e quantificar as complicações da cateterização venosa central em crianças internadas em Unidade de Terapia Intensiva Pediátrica (UTIP); identificar os fatores de risco para complicações de inserção e de manutenção e avaliar a necessidade do emprego de medidas de prevenção de complicações e, se necessário, propor modificação das normas e rotinas dos cuidados de enfermagem vigentes. Analisou-se prospectivamente todas as crianças e adolescentes (1 mês a 18 anos de idade) internados na UTIP no período de um ano e que foram submetidos a punção venosa central, no ambiente da unidade. No período, 120 CVCs foram inseridos em 83 crianças. Os residentes (R3) inseriram 84,2% dos CVCs e não houve correlação entre complicações de inserção e manutenção e o profissional que realizou o procedimento.A taxa de sucesso de punção foi alta. A veia mais puncionada foi a jugular interna (79,2%), observando-se que sete tentativas de punção foram mal sucedidas (5,8%). As complicações de inserção mais freqüentes foram mal posicionamento do cateter (14,1%) e punção arterial (10,9%). Mais de três tentativas de punção foi significante para o aparecimento de intercorrências de inserção dos CVCs (p=0,004). Quanto as complicações de manutenção, houve correlação significante para troca do cateter realizada com fio guia (p=0,008), utilização de ventilação mecânica (p=0,025) e tempo de permanência do cateter por mais de sete dias (p=0,001). Sinais flogísticos ocorreram em 68,2% dos locais de inserção... / Central Venous Catheters (CVCs) are considered indispensable in the current medical practice. The aim of this study was to identify and to analyze the complications of the venous catheterization in children admitted in the Pediatric Intensive Care Unit (PICU) - UNESP, and to identify the risk factors for insertion and maintenance of CVCs. Also we aim to evaluate the necessity from prevention measures of complications and if it is necessary to change nursing care routine. During one year we analyzed prospectively 120 CVCs inserted in 83 children aged between 1 month and 18 years. Residents (R3) inserted 84.2% CVCs and no differences were observed between insertion and maintenance complications and the professional responsible for the procedure. Success punction rate was level. Internal jugular vein was the most punctioned vein (79,2%), and only 7 attempts failure (5,8%). Insertion complications more frequent were catheter bad positioned (14,1%) and arterial punction (10,9%). More than three attempts were statistical significant to insertion complication (p=0.004) and CVCs changed with guidewire were significant (p=0.008) to maintenance complications, as well as mechanical ventilation and indwelling time more than 7 days. Local infection was diagnosed in 68,2% and there were two cases of bloodstream-catheter-related infection. Constant observation of the nursing techniques, have showed that 82.3% of the nursing personal did not wash their hands before dressing, verifying association between no washing hands and appearing local infection catheter (p=0,005). Coagulase-negative Staphylococcus was the most common microorganism isolated from the catheters. Results aim the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters. Results make clear the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters.
4

Point of care-Ultraschall versus Röntgen-Thorax zur Lagekontrolle zentralvenöser Katheter / Point of care echocardiography versus chest radiography for central venous catheter position assessment

Mavropoulou, Eirini 25 September 2017 (has links)
No description available.
5

Detecting central-venous oxygen desaturation without a central-venous catheter: utility of the difference between invasively and non-invasively measured blood pressure / 観血的動脈圧と非観血的動脈圧の差を利用した中心静脈血酸素飽和度の推定

Kumasawa, Junji 23 September 2016 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(社会健康医学) / 甲第19969号 / 社医博第74号 / 新制||社医||9(附属図書館) / 33065 / 京都大学大学院医学研究科社会健康医学系専攻 / (主査)教授 小池 薫, 教授 福田 和彦, 教授 木村 剛 / 学位規則第4条第1項該当 / Doctor of Public Health / Kyoto University / DFAM
6

A 3D-ultrasound guidance device for central venous catheter placement using augmented reality / En 3D-ultraljud guidningsanordning för central venös kateter placering med användning av förstärkt verklighet

Jansson, Magnus January 2017 (has links)
Central venous catheterization (CVC) is performed frequently in clinical practices in Operation Rooms(OR) and Emergency Rooms(ER). CVC is performed for different reasons such as supply nutrition or medicine. For CVC ultrasound (US), diagnostic device is preferable among other medical imaging technologies. Central Venous Catheterization (CVC) under the 2D US guidance requires skills for catheter placement to avoid damaging non-targeted blood vessels. Therefore, there is a great need for improvements in the CVC field where mechanical complication has a risk of occurring during the procedure, for example misplacement of the needle. This master thesis project was performed at Kyushu University department of mechanical engineering and collaboration with Maidashi Kyushu University Hospital department of Advanced Medicine and Innovative Technology in Japan. This thesis is aimed to develop a new simple and cheap guidance system for CVC placement. The system performed on a Tablet PC and will be using already existing Ultrasound machines in Hospitals and Augmented Reality(AR). The project developed a simple AR-System for CVC placement with use of the ArUco library. The new developed system takes information from Ultrasound images and constructs a 3D-model of a vein and artery. Then the 3D-model is augmented on the patient through the tablet PC by using the ArUco library. The construction and augmentation is all performed on the tablet PC and has a small computation to complete the necessary procedures for the 3D-blood vessels. The AR-system has a simple control where the interface of the system is a simple push and action system. When a good visualization of the blood vessels and Doppler effect is shown on the ultrasound machine, the surgeon presses the screen and the image is saved. After about five images are acquired, the system builds the 3D-model and augments it on the patient using a marker. For the development of this system it implemented the waterfall method where each step was tested and checked, before moving to the next step. A full functional system was developed and tested. From the tests performed it is shown that there were limitations due to segmentation and depth perception. But the system has possibilities as an aid for CVC placement.
7

Incidência e fatores de risco de remoção por suspeita de infecção de corrente sanguínea associada ao cateter central de inserção periférica em uma coorte de neonatos / Incidence and risk factors of removal due to suspected catheter-associated bloodstream infection of Peripherally Inserted Central Catheter in a cohort of neonates.

Magalhães, Talita Elci de Castro 26 July 2013 (has links)
Introdução: o cateter central de inserção periférica (CCIP) tornou-se amplamente utilizado nas unidades de terapia intensiva neonatal (UTIN) na última década em razão da facilidade de sua instalação, permitindo a infusão de soluções endovenosas vesicantes, irritantes, hiperosmolares e de longa duração em veias centrais. Uma das complicações mais temidas relacionadas ao uso do CCIP é infecção de corrente sanguínea associada ao cateter cujo diagnóstico se confirma somente após a sua remoção, com o resultado de cultura da ponta do dispositivo e o resultado de hemocultura periférica do neonato. Objetivo: determinar a incidência de remoção por suspeita de infecção de corrente sanguínea relacionada ao CCIP e identificar os seus fatores de risco. Metodologia: coorte prospectiva composta por neonatos com CCIP internados em uma Unidade de Terapia Intensiva Neonatal de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 30 de agosto de 2012. As variáveis de exposição analisadas foram às relacionadas às características demográficas e clinicas dos neonatos, procedimentos relacionados à inserção do cateter, tipo de terapia intravenosa infundida pelo CCIP e o tempo de permanência do cateter. O desfecho analisado foi o motivo de remoção do cateter - eletivo ou por suspeita de infecção. Os dados obtidos de registros de prontuário foram armazenados em planilha Microsoft Excel 2010® e analisados com o software Stata 11,1. Foram determinadas medidas de tendência central e dispersão para as variáveis contínuas e frequências absolutas e relativas para as variáveis nominais. A existência de associação entre as variáveis de exposição e desfecho foi determinada pelo teste Qui-quadrado (teste 2), exato de Fisher e t Student. As variáveis com valor p < 0,05 foram incluídas na análise multivariada com regressão de Poisson. O nível de significância estatística adotado foi p < 0,05 com intervalo de confiança de 95%. O projeto de pesquisa foi aprovado pelo Comitê de Ética e Pesquisa da instituição campo do estudo. Resultados: A coorte inicial foi composta por 551 neonatos com CCIP e atenderam os critérios de elegibilidade, 401. A incidência de remoção por suspeita de infecção associada ao cateter foi 13,7%. A média de permanência de cateteres removidos por suspeita de infecção foi de 16,4 dias e dos removidos eletivamente, 11,7 dias, valor p=0,0001. Os fatores de risco para remoção por suspeita de infecção foram os diagnósticos de distúrbio hidroeletrolítico, RR 3.04. IC95%[1,727-5,054], valor p = 0,000 e apnéia, RR 2,38, IC95% [1,105-4,564], valor p = 0,016. As variáveis, média da idade gestacional corrigida superior a 32 semanas, RR 0,893, IC95% [0,832-0,956], valor p = 0,002 e o uso de cateter monolúmen de silicone, RR 0,278, IC95% [0,128-0,536], valor p = 0,000 se configuraram como fatores de proteção para remoção por suspeita de infecção associada ao CCIP. Dos 72 cateteres removidos por suspeita de infecção, 3 (4,2%)apresentaram confirmação de infecção do cateter. Conclusão: Os resultados sugerem que os diagnósticos identificados como fatores de risco devem ser incluídos no protocolo assistencial como fatores preditores de remoção por suspeita de infecção. Estes recém-nascidos necessitam ser especialmente monitorados em busca de sinais de infecção. Além disso, a escolha do tipo de dispositivo CCIP deve ser objeto de mais investigações, bem como os critérios de decisão para remoção do CCIP, por suspeita de infecção, tendo em vista a reduzida frequência de confirmação de infecção entre os cateteres removidos por suspeita. / Introduction: The peripherally inserted central catheter (PICC line) has become widely used in the neonatal intensive care units (NICU) in the last decades due to its ease installation and to allow infusion of vesicant, irritant and hiperosmolar solutions by long period in central veins. One of the most feared complications related to the use of PICC lines is the catheter associated bloodstream infection, which is confirmed after its removal with the result of catheter\'s tip culture and the results of neonate peripheral blood culture. Objective: to determine the incidence of removal due to PICC-line associated bloodstream infection and identify its risk factors. Methods: a prospective cohort of neonates with PICC line hospitalized in a NICU of a private hospital of the city of São Paulo. Data were collected from August 31st, 2010 to August 30th, 2012. The independent variables analyzed were related to demographic and clinical characteristics of newborns, procedures related to insertion of catheter, type of intravenous therapy infused and the catheter dwell time. The outcome variable analyzed was the reason for catheter removal elective or due to PICC-line suspected bloodstream infection. Data were obtained from the medical charts and stored in Microsoft Excel 2010 ® spreadsheet. Statistics analysis was conducted in the software Stata 11.1®. The continuous variables were showed by central and dispersion tendency measures and for qualitative variables, the data were showed by absolute and relative frequencies. The association between independent and outcome variables was determined by chi-square test (2), Fisher exact and t Student. Variables with p <0.05 were included in Poisson multivariate regression model. The level of statistical significance adopted was p<0.05 with a confidence interval of 95%. The research project was approved by the Ethics and Research Committee of the hospital where the study was carried out. Results: the initial cohort was composed of 551 neonates with PICC-line and 401 met the eligibility criteria. The incidence of suspected catheter associated bloodstream infection removal was 13.7%. The mean dwell time of PICC removed due suspicious of infection was 16,4 days and due to elective removal was 11,7 days, p value=0,0001. The risk factors for catheter-associated bloodstream infection identified were the diagnosis of hydroelectrolytic disorder, RR 3.04, CI95% [1.727 - 5.054], p value= 0.000 and diagnose of apnea, RR 2.38, CI95% [1.105 - 4.564], p value=0.016. The variables identified as protective factors for removal due suspected infection were: corrected gestational age of more than 32 weeks, RR 0.893, CI95% [0.832 - 0.956], p value=0.002 and single-lumen silicone catheter, RR 0.278, CI95% [0.128 - 0.536], p value= 0.000. From 72 catheters removed due to PICC-line suspicious of bloodstream infection, the infection was confirmed only to 3 (4.2%)of them. Conclusion: The results suggested that the diagnosis identified as risk factors should be included in the protocol of PICC lines management as predictors for removal due to suspected of infection. These neonates need to be carefully monitored for signs of infection. Moreover, choosing the most appropriate type of PICC should be further investigated, as well as the criteria to support the decision of removing the catheter considering the low number of confirmed catheter-associated infection.
8

Tipo de cateter central de inserção periférica e o motivo de sua remoção em uma coorte de neonatos / Type of peripherally inserted central catheter device and the reason for its removal in a cohort of neonates

Paiva, Eny Dórea 30 July 2012 (has links)
Introdução: Dispositivos de acesso venoso central tornaram-se vitais para a recuperação e sobrevivência dos neonatos e lactentes internados em Unidade de Terapia Intensiva Neonatal (UTIN). O cateter central de inserção periférica (CCIP) tem sido amplamente utilizado para atender às demandas terapêuticas dos neonatos e lactentes criticamente doentes e inovações nos dispositivos têm sido introduzidos e confeccionados com materiais biocompatíveis, como o silicone e o poliuretano, com único ou duplo lúmen. Objetivo: analisar a relação entre os tipos de cateteres centrais de inserção periférica (monolúmen de silicone e duplolúmen de poliuretano) instalados em neonatos e lactentes com os motivos de remoção do dispositivo. Método: coorte prospectiva, composta por neonatos e lactentes submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo, no período de 1 de julho de 2010 a 30 de junho de 2011. Os neonatos e lactentes foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 219/2010). Resultados: foram analisados dados referentes a 270 CCIPs, 189 (70%) cateteres de monolúmen e 81 (30%) de duplolúmen. Os dois grupos de cateteres apresentaram características demográficas, clínicas, terapêuticas e relacionadas ao procedimento de inserção do cateter homogêneas, exceto para as variáveis: diagnóstico prévio de septicemia (p=0,0210) e ocorrência de dificuldade de progressão do cateter na instalação do mesmo (p=0,0296). Contudo, o valor de p para o teste de homogeneidade para razão de chances do diagnóstico prévio de septicemia e da dificuldade de progressão do cateter, não demonstrou diferença estatística, p=0,955 e p=0,400, respectivamente. A taxa de densidade de incidência (TI) de remoção não eletiva para o cateter monolúmen de silicone foi 34,8 em 1.000 cateteres-dia e a do cateter duplolúmen de poliuretano foi 32,8 em 1.000 cateteres-dia. Houve diferença estatística significante, p=0,0005, na média do tempo de permanência entre os dois tipos de cateteres, maior para o dispositivo de duplolúmen de poliuretano, 14 dias em relação ao dispositivo de monolúmen de silicone, 10 dias. Entretanto, não é possível afirmar que a taxa de densidade de incidência entre os cateteres se diferem entre si ao se estimar a curva de sobrevida pelo método Kaplan Meier dos cateteres com remoção não eletiva. As curvas de sobrevivência de ambos os cateteres se sobrepõem, entretanto o valor do logrank (0,45) indica que não há diferença estatística entre a incidência de remoção não eletiva entre os cateteres. Dessa forma, a hipótese conceitual defendida no presente estudo não pode ser confirmada. Conclusão: os resultados do estudo apontaram que não há diferença estatística significante nas taxas de incidência de remoção não eletiva entre os dois grupos de cateteres. Entretanto, o CCIP de duplolúmen de poliuretano apresentou média de tempo de permanência maior comparado ao dispositivo de monolúmen de silicone. / Introduction: Central venous access devices have become vital to the recovery and survival of newborns and infants hospitalized in the Neonatal Intensive Care Unit (NICU). The peripherally inserted central catheter (PICC) has been widely used to supply the therapeutic demands of critically ill newborns. Innovation in the PICC devices have been available, made from biocompatible materials such as silicone and polyurethane, with single or double lumen. Objective: To analyze the relationship between the type of peripherally inserted central catheter device (silicone single lumen or polyurethane double lumen) used in neonates and infants with the reasons for their removal. Method: prospective cohort study consisting of neonates and infants undergoing installation of PICC devices, admitted at the NICU of a private hospital in the city of São Paulo in the period from July 1st, 2010 to June 30, 2011. The neonates and infants were enrolled at the time of catheters installation and followed up until PICC device removal. The research project was examined and approved by the Institutional Research Ethics Boards where the study was carried out (Protocol number 219/2010). Results: Data from 270 PICC devices installed in 213 neonates, 189 (70%) silicon single lumen catheter and 81 (30%) with polyurethane double lumen catheter devices, were analysed. The distribution of demographic, clinical, therapeutic and cathers insertion procedure variables were homogeneous between the two groups of catheters, except for the variables: previous diagnosis of septicemia (p=0,0210) and difficulty on the progression of the catheter during the catheter instalation (p=0,0296). However, the p value for homogeneity test for the odds ratio for the diagnosis of septicemia and the difficulty of catheter progression, no have statistical difference, respectively p=0,955 and p=0,400. The rate of incidence density (ID) for non-elective silicon single lumen catheter removal was 34,8 per 1.000 catheter-days and for the polyurethane double lumen catheter was 32,8 per 1.000 catheter-days. Difference statistically significant, p=0,0005, in the average of length of stay between the two types of catheters was found, the polyurethane double lumen was largest, 14 days, silicone single lumen was 10 days. However, it is not possible to state that the rate of incidence density between the catheters is different when estimated by the Kaplan Meier method survival curve of the catheters with non-elective removal. The survival curves of both catheters overlap in 20th to 25th days, and the logrank value, 0,45, indicates no statistical difference in the non-elective removal catheters incidences between the two types of catheters. Thus, the statistical hypothesis in the length of stay of non-elective removal between both catheters can not be rejected, not confirming the theoretical hypothesis of this study. Conclusion: The results of the study indicate that there is no statistically significant difference in the incidence rates of non-elective removal between the two types of catheters. However, the polyurethane double lumen catheter had higher length of stay mean compared to the silicone single lumen catheter.
9

Análise da relação entre a posição anatômica da ponta do cateter CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos / Analysis of the relation between anatomical location of PICC tip and the reason for the removal of the device in a cohort of neonates

Costa, Priscila 24 November 2011 (has links)
Introdução: O uso do Cateter Central de Inserção Periférica (CCIP) vem sendo cada vez mais frequente em neonatos internados em Unidades de Terapia Intensiva Neonatal (UTIN) em razão da necessidade de um dispositivo de acesso venoso seguro para infusão de drogas irritantes e nutrição parenteral. Detalhes técnicos do CCIP, especialmente a posição anatômica de sua ponta são descritos como fatores de risco para complicações que podem culminar em remoção não eletiva do dispositivo. Objetivo: analisar a relação entre a posição anatômica da ponta do CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos. Método: coorte concorrente, composta por neonatos submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 01 de julho de 2011. Os neonatos foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 238/2010). Resultados: foram analisados dados referentes a 237 CCIPs, dos quais, 207 (86,9%) tiveram posicionamento central da ponta (grupo central) e 30 (12,5%) posição não central da ponta (grupo não central). Nos grupos central e não central, as médias da idade gestacional corrigida, idade pós-natal e peso foram, respectivamente: 34,1 semanas e 33,8 semanas; 9,9 dias e 10,4 dias; 1.936,8 gramas e 1.867 gramas, com homogeneidade entre os grupos, exceto em relação ao diagnóstico de afecção cardíaca, com maior proporção no grupo com cateter não central (p=0,0472). O sitio de inserção, tipo de cateter e terapia intravenosa instituída foram semelhantes entre os grupos. A maioria dos CCIPs (62,3%) foi removida eletivamente. A incidência de remoção não eletiva do CCIP foi maior entre os cateteres não centrais (43,3%), em comparação aos centrais (36,7%) não apresentando diferença estatisticamente significante entre os grupos (p=0,4842). O risco relativo de remoção não eletiva foi 1,18 (IC 95%: 0,76-1,84) vezes maior para os cateteres não centrais. Os principais motivos de remoção não eletiva nos cateteres centrais foram obstrução, ruptura e suspeita de infecção de corrente sanguínea relacionada a cateter, e nos cateteres não centrais foram: tração acidental, suspeita de infecção de corrente sanguínea relacionada a cateter e extravasamento. Houve diferença estatística significante quanto à incidência de extravasamento nos cateteres não centrais em relação aos centrais (p=0,0092). A taxa de incidência (TI) de extravasamento foi 0,8 por 1.000 cateteres-dia em cateteres centrais e 10,2 por 1.000 cateteres-dia nos cateteres não centrais. As médias do tempo de permanência dos cateteres não centrais e centrais foram respectivamente de 9,8 dias e 11,7 dias sem diferença estatisticamente significante (p=0,1627). Conclusão: Os achados sugeriram não haver associação entre o posicionamento não central da ponta do CCIP e a ocorrência de remoção não eletiva do cateter. Entretanto, há necessidade de avaliação permanente do neonato quanto aos sinais de extravasamento / Background: The use of Peripherally Inserted Central Catheters (PICC lines) has become common in neonates admitted to Neonatal Intensive Care Units (NICU), due to the necessity of safe intravenous access for irritant drugs and parenteral nutrition. Some technical details of the PICC, especially the anatomical location of its tip are described as risk factors for complications leading to nonelective removal of this device. Aim: Analyze the relation between anatomical location of the PICC tip and the reason for the removal of the device. Methods: Prospective cohort, composed of neonates who underwent placement of the PICC, admitted to a private NICU in the city of São Paulo, from 31 August 2010 to 1st July 2011. The infants were enrolled after successfully catheter insertion and they were followed up until its removal. The research project was appraised and approved by the Ethics Committee of the institution, (Case 238/2010). Results: Data from 237 PICCs were analyzed, 207 (86.7%) were central in tip location (central group), and 30 (12.5%) were noncentral in tip location (non central group). At central and noncentral groups, the means of corrected gestational age, postnatal age and weight were respectively: 34.1 weeks and 33.8 weeks, 9.9 days and 10.4 days, 1936. 8 grams and 1.867 grams, both groups are homogeneous, except for the diagnosis of heart disease, with the highest proportion in the noncentral group (p=0.0472). The site of insertion, type of catheter and intravenous therapy were similar in both groups. Most of PICCs (62.3%) was removed electively. The incidence of nonelective removal was higher among noncentral catheters (43.3%) compared to central (36.7%) with no statistical significant difference (p = 0.4842). The noncentral group had a 1.18-fold increased risk of nonelective removal compared to central catheters. The main reasons for nonelective removal at the central group were obstruction, rupture and suspicion of catheter-related bloodstream infection, and at the noncentral group were accidental dislodgment, suspicion of catheter-related bloodstream infection and extravasation. There was a statistically significant difference in the incidence of extravasation at the noncentral group compared to central group (p=0.0092). The extravasation rate was 0.8 per 1.000 catheter-days at central group and 10.2 per 1.000 catheter-days at noncentral group. The catheter indwelling time at noncentral and central catheters were respectively 9.8 days and 11.7 days with no statistically significant difference (p=0.1627). Conclusion: The results suggested no association between noncentral tip location of the PICC and the occurrence of nonelective removal of the catheter. However, a continuous assessment of the neonate for the signs of extravasation is needed.
10

Parecer técnico-científico: uso do conector sem agulha para sistema fechado de infusões vasculares / Technical-scientific opinion: use of the needleless connector for a closed vascular infusion system

Roque, Simone Cristina da Silva 23 February 2018 (has links)
Submitted by SIMONE CRISTINA DA SILVA SANTOS (simoneenfer2009@gmail.com) on 2019-01-31T10:36:29Z No. of bitstreams: 1 SIMONE CRISTINA DA SILVA ROQUE.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2019-01-31T10:54:03Z (GMT) No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Made available in DSpace on 2019-01-31T10:54:03Z (GMT). No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) Previous issue date: 2018-02-23 / Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e colonização/contaminação da entrada de hub, não foram encontradas diferenças significativas entre os grupos. Conclusão: Considerando as evidências científicas, a recomendação da tecnologia avaliada é incerta para redução das infecções hospitalares. / Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were found between groups. Conclusion: Considering the scientific evidence, the recommendation of the technology evaluated is uncertain for the reduction of hospital infections.

Page generated in 0.1655 seconds