• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 197
  • 99
  • 98
  • 69
  • 55
  • 42
  • 38
  • 23
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Análise in vitro do efeito do monômero antibacteriano MDPB sobre a adesão bacteriana à resina composta / Influence of the MDPB monomer on the in vitro bacterial adherence to resin composite

Thaís Thomé 02 June 2005 (has links)
Um novo monômero, brometo de metacriloiloxidodecilpiridínio (MDPB), com efeito antibacteriano e capacidade de co-polimerizar com outros monômeros, foi apresentado por Imazato, Torii e Tsuchitani (1993). Este estudo avaliou a adesão bacteriana, em 16, 40 e 64 horas, à resina composta contendo ou não o monômero antibacteriano MDPB. A adesão foi testada para Streptococcus sanguinis e Streptococcus sobrinus. Após as amostras terem sido submetidas à incubação, o biofilme foi coletado e a contagem de UFCs foi realizada. Os dados foram comparados pelo método ANOVA complementado por teste de Tukey. Os resultados demonstraram que, para o S. sanguinis, a adesão sobre o MDPB foi significativamente maior (p<0.05) quando comparado ao controle em 16 horas, mas diminuiu significativamente em 40 horas, não apresentando diferenças quando comparado ao controle neste tempo (p<0.01). Para o S. sobrinus, o controle apresentou aumento significativo da adesão bacteriana em 64 horas quando comparado com 16 horas (p<0.01), sendo significativamente maior que para o MDPB em 64 horas (p<0.05). Assim, o estudo mostrou que o MDPB é capaz de inibir a adesão de S. sobrinus sem interferir na adesão do S. sanguinis. Portanto, nas condições deste estudo os resultados sugerem que a incorporação do MDPB a resinas compostas pode ser de importância na prevenção de cáries secundárias favorecendo a adesão de bactérias comensais em detrimento de bactérias com potencial cariogênico. / A new antibacterial monomer, Methacryloyloxydodecylpyridinium bromide (MDPB), with antibacterial property and ability to co-polymerize with other monomers, was introduced by Imazato, Torii and Tsuchitani (1993). This study aimed to analyze the effect of MDPB on bacterial adherence to resin composites containing or not MDPB. Streptococcus sanguinis and Streptococcus sobrinus were used. The biofilms were collected from the samples and the colony forming units (CFUs) were counted after 16, 40 e 64 h of incubation. The data were compared by ANOVA complemented by the Tukey’s test. The results showed that the adhesion of S. sanguinis to MDPB-containing resin composite was significantly higher (p<0.05) than to control samples at 16 h, but significantly diminished at 40 h, reaching values similar to those of control samples (p<0.01). The adherence of S. sobrinus to control samples significantly increased throughout the experimental time (p<0.01) and was considerably higher than to MDPB at 64 h (p<0.05). Thus, the study showed that MDPB is capable of inhibit adhesion of S. sobrinus with no interference on the adhesion of S. sanguinis. Thus, at the conditions of this study we suggest that MDPB incorporated to resin composites could be of importance to prevent secondary caries favoring adhesion of commensal bacteria and impairing adhesion of cariogenic bacteria.
142

Viabilidade da substituição de raízes de dentes humanos por raízes construídas em compósito para estudos de mecânica da fratura / Viability of replacing the roots of human teeth by roots made of composite for the study of fracture mechanics

Camila Oliveira Moraes Espósito 27 April 2012 (has links)
OBJETIVO: A restauração de dentes tratados endodonticamente é um desafio para a Odontologia. A fratura do remanescente radicular é comum neste tratamento. São três os métodos utilizados para estudar as fraturas: a análise por elementos finitos, os que utilizam dentes naturais e aqueles que utilizam dentes artificiais. O uso de dentes naturais apresenta alguns inconvenientes, como as variações anatômicas e de histórico de exposição a esforços (que aumentam a variabilidade da amostra e dificultam as conclusões), além da pequena disponibilidade de espécimes. Este estudo propõe-se avaliar a viabilidade de usar compósito para a construção de raízes artificiais e a aplicação dessas réplicas em estudos sobre a essas fraturas. MÉTODOS: Na primeira etapa foram utilizadas 50 raízes unirradiculares de 2º pré-molar superior e 50 réplicas. As raízes naturais foram selecionadas por terem características anatômicas semelhantes. As réplicas foram confeccionadas a partir de um molde de resina acrílica que copiou uma raiz natural com proporções dentro da média. O compósito foi escolhido pelas propriedades mecânicas mais próximas das propriedades mecânicas da dentina. Todas as raízes e as réplicas foram submetidas a forças compressivas de uma ponta metálica cônica (simulação do pino intrarradicular), até a fratura. A velocidade de avanço da ponta foi de 5mm/min. Na segunda etapa, foram confeccionadas 30 réplicas, divididas em 3 grupos (n=10). Todas foram restauradas com pinos metálicos fundidos e coroas metálicas. No grupo FZ os pinos foram cimentados com fosfato de zinco; no grupo CRD foi aplicada uma camada de vaselina sólida no conduto radicular e os pinos foram cimentados com cimento resinoso dual; no grupo CRC foi feita aplicação de um agente de união no conduto radicular e os pinos foram cimentados com cimento resinoso dual. Os espécimes foram submetidas a ciclagem mecânica de 130.000 ciclos sob pressão de 5bar. Duas raízes de cada grupo foram utilizadas para testar os parâmetros do ensaio de resistência à fratura. Em seguida, as outras raízes (n=8) foram submetidas ao teste de resistência sob forças compressivas até a ruptura. A carga foi aplicada com inclinação de 20º e velocidade de 5mm/min. RESULTADOS: Na comparação entre a resistência das raízes naturais e artificiais à penetração de pino no conduto radicular, houve diferença estatística entre os dois grupos. As raízes artificiais apresentam maior resistência à fratura (115,4MPa) do que as raízes naturais (75,4MPa). O coeficiente de variação das réplicas (21%) é menor que o das raízes naturais (36,3%), o que indica uma menor variabilidade da amostra das réplicas. Mesmo com valores diferentes, há semelhança na direção do traço de fratura e no local onde ocorrem. Esse resultado indica que a concentração de tensões e a propagação da fratura é semelhante em dentina e compósito. Quanto às réplicas restauradas com pinos, não houve diferença estatística entre os grupos. CONCLUSÃO: As raízes artificiais quando comparadas as raízes naturais, apresentam maior resistência à fratura, menor variação dos resultados individuais em torno da média e modo de fratura semelhante às raízes naturais. Desta maneira, é viável a utilização das réplicas nos estudos sobre mecânica da fratura. / OBJECTIVE: The restoration of endodontically treated teeth is a challenge for dentistry. The fracture of the remaining root is common in this treatment. There are three methods used to study fractures: a finite element analysis, using the natural teeth and those who use artificial teeth. The use of natural teeth has some disadvantages, such as anatomical variations and a history of exposure to stresses (which increase the variability of the sample and the findings difficult), beyond the limited availability of specimens. This study aims to evaluate the feasibility of using composite for the construction of artificial roots and application of these replicas in studies of these fractures. METHODS: In the first stage were used 50 single-rooted roots of 2nd premolar and 50 replicas. The natural roots were selected for having similar anatomical features. The replicas were made from an acrylic resin such that a natural root copied with ratios in the average. The composite was selected by the mechanical properties closer to the mechanical properties of the dentin. All the roots and the replicas were subjected to compressive forces of a conical metal tip (simulation post) until failure. The feed rate was tip of 5mm/min. In the second step, 30 replicas were prepared, divided into 3 groups (n = 10). All were filled with molten metal pins and metal crowns. In group A the posts were cemented with zinc phosphate, group B was applied to a solid layer of vaseline in the root canal and the posts were cemented with dual resin cement, in group C was made applying a bonding agent in the root canal and the posts were cemented with dual resin cement. The specimens were subjected to mechanical loading of 130,000 cycles under a pressure of 5bar. Two roots from each group were used to test the parameters of fracture toughness test. Then the other root (n = 8) were subjected to endurance test under compressive forces until failure. The load was applied with an inclination of 20° and speed 5mm/min. RESULTS: Comparing the resistance of natural and artificial root penetration of the pin in the root canal, was no statistical difference between the two groups. The artificial roots showed higher fracture strength (115.4 MPa) than the natural roots (75.4 MPa). The coefficient of variation of the replicas (21%) is less than the natural root (36.3%), indicating a lower variability of the replicas of the sample. Even with different values, there are similarities in the direction of the fracture site and where they occur. This result indicates that the stress concentration and fracture propagation is similar in dentin and composite. As for replicas restored with posts, no statistical difference between groups was found. CONCLUSION: The artificial roots showed greater resistance to fracture when compared to natural roots, less variation of individual results around the mean and mode of fracture similar to the natural roots. Thus, it is feasible to use in studies of replicas of fracture mechanics.
143

Comportamento bimodular em osso cortical e novo método para calcular o módulo de elasticidade (E) em resinas compostas / Bimodular behavior in cortical bone and a novel method for measuring elastic modulus (E) of composite resins

Lucas Vinicius Sansana Pabis 29 January 2015 (has links)
O objetivo principal foi investigar se o osso cortical apresenta comportamento bimodular, ou seja, se os valores de módulo de elasticidade (E) dependem do tipo de carregamento que o método utiliza. Para alcançá-lo foi preciso: (1) \"calibrar\" os diferentes métodos em um material conhecidamente unimodular, para afastar a possibilidade de erros ligados à execução de um método. (2) Depurar os métodos já calibrados para torná-los exequíveis em osso cortical. O que foi feito em espécimes de resina composta, que é um material unimodular e com E parecido com o do osso cortical. Foi investigado se o método de medida interfere no valor do E obtido neste material (pois, pelas informações da literatura, existia uma dúvida consistente). Finalmente, (3) foi avaliado se o método de medida, a região anatômica e o indivíduo interferem nos valores de E em espécimes de osso cortical. Adicionalmente, (4) verificou-se a possibilidade de se encontrar e validar uma correlação entre E e dureza Knoop (KH), para medir o E de resinas compostas indiretamente. Espécimes de latão (n = 5) tiveram o seu E calculado por quatro métodos estáticos diferentes (flexão em três pontos; tração; compressão e método de Marshall), que foram calibrados até que todos medissem o valor esperado; os valores de cada método foram comparados por análise de variância de medidas repetidas (o método foi o fator vinculado e o nível de significância foi de 5%). Espécimes (n = 4) de cinco marcas diferentes de resina composta, também foram submetidos aos quatro métodos, fazendo as adaptações pertinentes (depuração), e tiveram o seu E calculado. Estes valores foram submetidos à análise de variância de medidas repetidas (o método foi o fator vinculado e o nível de significância foi de 5 %). Espécimes (n = 48) obtidos em diferentes regiões (periósteo, endósteo e \"transversal\") de fêmures de quatro bois diferentes tiveram seu E calculado através dos métodos devidamente depurados (flexão em três pontos, tração indireta e compressão). Os valores de E foram submetidos a análises de variâncias (nível de significância de 5 %) para avaliar a influência do método, da região e do indivíduo (bois diferentes) sobre os valores de E. O método experimental de tração não foi utilizado para analisar o comportamento bimodular, porque durantes os ensaios com osso cortical, ele apresentou valores com viés. Por isso, os valores de tração foram calculados de forma indireta (Eti) através de uma equação e dos valores experimentais de flexão em três pontos (Eb) e compressão (Ec). Para validar o uso de valores de Eti, eles foram comparados com os respectivos valores de tração experimental (Et) calculados previamente nos espécimes de resinas compostas por análise de variância de medidas repetidas, e não foram achadas diferenças significantes (p > 0,05). Para encontrar e validar a correlação entre E e KH, os valores médios de E em cada espécime de resina (média do E obtido nos 4 métodos em cada espécime) foram submetidos ao teste de correlação de Pearson (nível de significância de 5%) com os respectivos valores experimentais de dureza Knoop (KH) e foi obtida uma equação de regressão linear. Para validar a equação foi confeccionado um segundo grupo de espécimes de resina (de marcas diferentes das utilizadas anteriormente) que teve seu E calculado pelo ensaio de flexão (Eb) e pela equação de regressão proposta previamente (Er); verificou-se então se a correlação entre estes valores (Eb x Er) era significante (nível de significância de 5 %), e se a nova reta de regressão apresentava coeficiente angular não diferente de 1, e coeficiente constante não diferente de zero (critérios de validação). A análise de variância não apontou diferença significante (p > 0,05) entre os valores de E calculados para o metal pelos 4 métodos, e os valores obtidos não diferiram do E conhecido do latão (ao redor de 100 GPa). As depurações necessárias foram realizadas e com elas os diferentes métodos calcularam o E dos espécimes de resina composta de modo consistente: a análise de variância encontrou diferenças significantes (p < 0,05) entre marcas (cujos E médios cobriram a faixa entre 3 e 20 GPa) e não significantes entre os 4 métodos (p > 0,05). Nos espécimes de osso cortical o valor de E foi significantemente dependente (p < 0,05) do método de obtenção (Eti > Eb > Ec). O E dos espécimes obtidos na região \"transversal\" foi menor que o E dos espécimes obtidos na região do endósteo (p < 0,05); no entanto, não houve diferença significante (p > 0,05) entre o E dos espécimes obtidos nas regiões do endósteo e periósteo e entre o E dos espécimes obtidos nas regiões do periósteo e \"transversal\". Ao considerar somente os valores obtidos no ensaio de compressão (Ec), um dos indivíduos apresentou valores de E maiores que os demais (p < 0,05). As médias de E (dos quatro métodos) em cada espécime de resina apresentaram correlação significante com os respectivos valores de KH (p < 0,05) e a equação de regressão linear: E = 0,1602 KH. Também foi significante (p < 0,05) a correlação dos valores de Eb com os respectivos valores de Er (calculados pela regressão E = 0,1602 KH); além disso, a reta de regressão linear desta nova correlação (Eb = 1,0088Er + 0,0475) apresentou coeficiente angular não diferente de 1 e coeficiente constante não diferente de zero. Pode-se concluir que: (1) Quatro métodos de medir o E apresentaram resultados semelhantes em um material metálico. (2) Estes mesmos métodos foram depurados com sucesso para sua utilização em espécimes de osso cortical ao constatar que também não interferiram no valor do E obtido em espécimes semelhantes aos de osso, confeccionados com resinas compostas. (3) Os valores de E de osso cortical dependem do método de medida, o que demonstra seu comportamento bimodular. A região anatômica e o indivíduo também afetam os valores de E dos espécimes de osso cortical (o indivíduo só foi um fator significante ao considerar somente os valores obtidos no ensaio de compressão). (4) Foi encontrada e validada uma correlação entre E e KH em resinas compostas, que permite calcular o E deste material através da regressão E = 0,1602 KH. / The main objective was to investigate whether the cortical bone has a bimodular behavior, that is, if the values of elastic modulus (E) depend on the load type used by the method. To achieve this, it was necessary: (1) \"calibrate\" the different methods in a material with well-known unimodular behavior, for excluding the possibility of systematic errors in the execution of the methods. (2) Depurate the calibrated methods to make them executable in cortical bone. This was made on specimens of composite resin, which is a unimodular material and has an E similar to that of cortical bone. It was also investigated if the method of measuring the E influences the obtained value in this material (because there was a consistent doubt in the literature). Finally (3), we assessed whether the E values in cortical bone are influenced by the measurement method, by the anatomical region and by the individual. Additionally, (4) it was verified if it would be possible suggesting and validating a correlation between E and Knoop hardness (KH), to indirectly measure the E of composite resins. Brass specimens (n = 5) had their E calculated by four different static methods (three point bending, tensile, compression and Marshall\'s method), which were calibrated until all the methods were capable of measuring the expected value; the E values of each method were compared by analysis of variance of repeated measures (the method was the linked factor and the significance level was 5%). Specimens (n = 4) of five different composite resins were also subjected to the four methods, making the relevant adjustments (depuration), and had their E calculated. These values were subjected to analysis of variance of repeated measures (the method was the linked factor and the significance level was 5%); Specimens (n = 48) obtained in different regions (periosteum, endosteum and \"transverse\") of bovine femurs from four different individual had their E calculated using the depurated methods (three point bending, indirect tensile and compression). The E values were subjected to analyzes of variance (significance level of 5%) to evaluate the influence of the method, of the region and of the individual (different cattle) in the E values. The experimental tensile method was not used to analyze the bimodular behavior because during tests on cortical bone, this method showed values with bias. Therefore, the tensile values were indirectly calculated (Eti) by a formula and by the experimental values of E calculated by three point bending (Eb) and compression (Ec). To validate the use of Eti values, they were compared with the corresponding tensile experimental values (Et) previously measured in the composite resins specimens by analysis of variance (repeated measures), and no significant difference was found (p > 0.05). For suggesting and validating the correlation between E and KH, the average values of E of each composite specimen (mean of E obtained considering the values of the four methods in each specimen) were submitted to the Pearson\'s correlation test (significance level of 5 %) with the corresponding experimental KH values and it was obtained the linear regression equation. To validate this equation, it was made a second group of composite resins specimens (with different brands of the previously used) in which the E was calculated by three point bending test (Eb) and by regression equation previously proposed (Er); then it was checked whether the correlation between these values (Eb x Er) was significant (significance level of 5 %), and if the new regression line showed angular coefficient no different from one, and constant coefficient no different from zero (validation criteria). The analysis of variance showed no significant difference (p > 0.05) among the E values calculated for the metal specimens by the four methods; the obtained values did not differ from the known E of the brass (about 100 GPa). The necessary adjustments (depuration) were made and then the different methods calculated the E of the composite resin specimens consistently: the analysis of variance found significant difference (p < 0.05) between composite brands (whose E mean covered the range between 3 and 20 GPa) and no significant difference among the four methods (p> 0.05). In the specimens of cortical bone, the E values were significantly dependent (p < 0.05) of the obtainment method (Eti > Eb> Ec). The E values of the \"transversal\" specimens were lower than the endosteum specimens (p < 0.05); but there was no significant difference (p > 0.05) between the E of endosteum specimens and periosteum specimens and between the E of periosteum specimens and \"transversal\" specimens. When considering just E values of the compression method, one cattle showed higher E values than the others (p < 0.05). The mean of the four methods for each specimen composite resin exhibited a significant correlation with the respective KH values (p < 0.05) and the linear regression equation: E = 0.1602 KH. It was also significant (p < 0.05) the correlation between Eb and the respective Er values (calculated by the regression E = 0.1602 KH); furthermore, the linear regression of this new correlation (Eb = 1.0088Er + 0.0475) presented angular coefficient no different from 1, and constant coefficient no different from zero. It can be concluded that: (1) Four methods of E measuring showed similar results in a metallic material. (2) The same methods were successfully depurated for their execution in cortical bone specimens, since the measurement method did not affect the obtained E value in resin composites (that is a material with E value similar to cortical bone); (3) The E values of cortical bone depend on the measurement method, which demonstrates its bimodular behavior. The anatomical region and the individual also affect the E values of the cortical bone specimens (the individual was a significant factor only when considering just the E values obtained in the compression test). A correlation between E and KH that allows the E estimation by the regression E = 0.1602 KH was suggested and validated in composite resins.
144

Avaliação da citotoxicidade e expressão de citocinas induzidas por resina composta fotopolimerizável / Evaluation of the Cytotoxicity and Cytokine Expression Induced by Light-Cured Composite Resins

Daniele Lucca Longo 14 June 2013 (has links)
O objetivo deste estudo foi avaliar, in vitro, o comportamento citotóxico e a produção de citocinas induzidos pelos materiais restauradores resinosos contendo novos monômeros KaloreTM (GC FUJI) e FiltekTMSilorane (3M ESPE) em comparação com as resinas compostas convencionais Charisma® (Heraeus-Kulzer) e FiltekTM Z250 (3M ESPE), em cultura de fibroblastos L929 e macrófagos RAW 264.7 de camundongos. As células foram estimuladas com as resinas compostas, fotopolimerizadas ou não, a partir da colocação em contato indireto ou pela extração de seus componentes durante 15, 45 e 120 dias. Após a incubação por 6, 12 e 24 horas, a viabilidade celular foi avaliada pelo Ensaio MTT e a produção de citocinas foi investigada pelo ensaio imunoenzimático (ELISA). Os dados obtidos foram analisados utilizando-se análise de variância de uma via (One-way ANOVA) e pós-teste de Tukey (&alpha;=0,05). A produção de TNF-&alpha; e IL-6 não foi detectada em fibroblastos da linhagem L929, após 6, 12 e 24 horas de contato indireto com as resinas compostas KaloreTM e FiltekTM Silorane. Por outro lado, a produção de TNF-&alpha; foi detectada em macrófagos da linhagem RAW 264.7, mas não foi influenciada pelo contato indireto com as resinas compostas, com exceção da resina FiltekTM Silorane que inibiu a produção de TNF-&alpha;, após 12 horas de incubação. Os extratos obtidos das resinas compostas KaloreTM e FiltekTM Silorane incubadas por 15 dias, se mostraram mais citotóxicos do que os extratos incubados por 45 e 120 dias. A citotoxicidade da resina composta KaloreTMnão foi influenciada pela fotopolimerização enquanto a citotoxicidade da resina FiltekTM Silorane foi maior no grupo não fotopolimerizado. Os extratos das resinas compostas Charisma® e FiltekTM Z250, obtidos aos 15, 45 e 120 dias de incubação, não foram citotóxicos 24 horas após a estimulação das células. Ainda, a resina FiltekTM Silorane, fotopolimerizada ou não, estimulou a produção de IL-6 no período de 45 dias de extração. A resina KaloreTM, diferentemente da resina FiltekTM Silorane, estimulou a produção de IL-10, aos 15 dias de extração. Entretanto, no período de 45 de extração, a resina KaloreTM fotopolimerizada inibiu a produção de IL-10, após 12 horas de incubação, e aos 120 dias de extração não houve produção detectável de IL-10 em nenhum dos grupos avaliados. / The aim of this study was to evaluate in vitro the cytotoxicity and the production of cytokines induced by resin-based restorative materials containing new monomers KaloreTM (GC FUJI) and FiltekTM Silorane (3M ESPE) compared with conventional composite resins Charisma® (Heraeus-Kulzer) and FiltekTM Z250 (3M ESPE), in mice L929 fibroblast and RAW 264.7 macrophages culture. Cells were stimulated with the composite resins, light-cured or not, by indirect contact or extraction during 15, 45, and 120 days. After incubation for 6, 12, and 24 hours, cell viability was assessed by MTT assay and production of cytokines was investigated by enzyme-linked immunosorbent assay (ELISA). Data obtained were analyzed using oneway analysis of variance (ANOVA) and Tukey post-test ( &alpha; = 0.05). Production of TNF-&alpha; and IL-6 was not detected in L929 fibroblasts either 6, 12 or 24 hours following indirect contact with the KaloreTM and FiltekTM Silorane composite resins. On the other hand, the production of TNF-&alpha; was detected in RAW 264.7 macrophages, but was not influenced by indirect contact with composite resins, with the exception of the FiltekTM Silorane resin that inhibited the production of TNF-&alpha;, after 12 hours of incubation. The extracts obtained from incubation for 15 days with composite resins KaloreTM and FiltekTM Silorane were more cytotoxic than extracts incubated for 45 and 120 days. Cytotoxicity of composite KaloreTM was not influenced by light curing while cytotoxicity of FiltekTM Silorane resin was higher in the group that not received light-cure. Extracts of Charisma® and FiltekTM Z250 composite resins, obtained at 15, 45, and 120 days of incubation, were not cytotoxic 24 hours after stimulation of the cells. Also, FiltekTM Silorane, light-cured or not, stimulated the production of IL-6 following 45 days of incubation. KaloreTM resin extract for 15 days, unlike FiltekTM Silorane resin, stimulated the production of IL-10. However, during periods of 45 days of extraction, KaloreTM resin, light-cured, inhibited the production of IL-10, after 12 hours of incubation, and 120 days of extraction there was no detectable production of IL-10 in any of the groups.
145

Técnica de replicação de raízes dentárias em resina composta fotopolimerizável a partir de molde de resina acrílica autopolimerizável / Root tooth replication technique in photo polymerized composite resin made by means of an acrylic resin mold by self polymerized resin

Sergio Luiz da Silveira Camargo 08 February 2011 (has links)
Pelas fraturas que sofrem os dentes caninos, torna-se necessário tratá-los endodonticamente, e repará-los proteticamente. Porém, novas fraturas coronais, com ou sem perda de coroa metálica podem se repetir. Muitas técnicas restauradoras priorizam os dentes com maior percentual de porção coronal, porque a extensa área de coroa remanescente assegura execução facilitada, favorecendo a recuperação do elemento dental e garantindo sucesso do assentamento da peça metálica. As pesquisas realizadas para se conseguir novos tratamentos utilizam dentes naturais para simular a realidade. Não há banco de dentes rotineiro na Odontologia Veterinária. O uso de dentes naturais de animais encontra restrições por conta da grande diversidade de raças e de porte entre cães, consequentemente no tamanho e na anatomia dos dentes. Existe ainda a carência de disponibilidade de amostras naturais na quantidade necessária para desenvolver tais estudos. O material artificial capaz de substituir os dentes naturais pode estar nas resinas compostas fotopolimerizáveis que apresentam propriedades mecânicas semelhantes às da dentina. Para se replicar o dente natural em resina composta, foi criado um molde em resina acrílica transparente. A literatura deste assunto é escassa ou mesmo inexiste. Com a construção de dentes artificiais muitas pesquisas podem ser realizadas, pois as amostras dentárias serão padronizadas de acordo com a necessidade de cada estudo a ser desenvolvido. Neste trabalho objetivou-se reproduzir quarenta dentes artificiais (réplicas) para demonstrar a possibilidade do padrão de cópia a partir do uso de um molde de resina acrílica. Os resultados mostraram que as réplicas foram similares ao dente natural. / Due to the fractures that canine teeth suffer, it is necessary to treat these teeth endodonticaly and restore them prosthetically (with pin, post core and metallic crown) in its coronal portion. However a new coronal fracture can happen with or without loss of the prosthodontic work. Many of the techniques aim at the teeth with larger extension of remaining area of crown, which favors the crown preparation and fixation of the prosthesis. Many researches use natural teeth to simulate the real conditions. In Veterinary Dentistry there is no routine bank of teeth. However there is a variety of dog breeds with different sizes, as well as a great variety in extension of the teeth. Additionally there is large numbers of natural teeth available enough for use in all researches. The material that can substitute the natural teeth seems to be the photo polymerized composite resin, which has similar mechanical properties to dentin. To replicate the natural teeth in composite resin, a mold was created in acrylic transparent resin. Literature of this subject is spares or inexistent. With artificial replication of teeth many researches can be achieved, once the samples of teeth can be standardized, according to which study. This project aimed to reproduce 40 replicas to demonstrate the possibility of copy from a transparent acrylic mold. Results showed that the replicas were similar to the natural tooth.
146

Odontologia digital: estudo da concordância entre avaliação clínica e fotográfica de restaurações de resina composta / Digital dentistry: study of the agreement between clinical and photographic assessments on composite resin restorations

Vasconcelos, Cecilia Vilela Matias 01 December 2017 (has links)
O presente estudo teve por objetivo observar os níveis de concordância entre a avaliação clínica e fotográfica digital no diagnóstico de desempenho de restaurações posteriores (Classe I e Classe II) em resina composta. As avaliações clínicas foram feitas por dois examinadores (C1 e C2) calibrados (e-calib) usando critérios da Fédération Dentaire Internationale (FDI) considerando propriedades estéticas, funcionais e biológicas. Em cada momento de avaliação clínica, uma fotografia digital padronizada de cada restauração foi realizada. Dois examinadores digitais (D1 e D2), igualmente calibrados e usando os mesmos critérios avaliaram todas as imagens obtidas nas avaliações clínicas. Os dados foram analisados com Coeficiente de Cohen Kappa e teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Comparações intra (mesmo método) e inter (métodos diferentes) examinadores foram feitas. Os resultados revelaram que os níveis de concordância variaram de \"Perfeito\" a \"Justo\". Houve diferença significante (p < 0.05) intra-examinadores; entre C1 e C2 para o manchamento marginal; entre D1 e D2 para brilho superficial, estabilidade de cor e translucidez, forma anatômica, e fratura do material e retenção; inter-examinadores foram encontradas diferenças significantes em todas as propriedades estéticas (brilho superficial, manchamento marginal, estabilidade de cor e translucidez e forma anatômica) e funcionais (fratura do material e retenção e adaptação marginal) observadas. A associação entre a imagem digital e o exame clínico pode ser uma ferramenta promissora para detecção de falhas precoces em restaurações de resina composta, necessitando de mais estudos que investiguem o método digital. / The present study aimed to evaluate the agreement levels between clinical and digital photographic assessments on the performance of posterior composite resin restorations (Class I and Class II). The clinical assessments were made by two examiners (C1 and C2) calibrated through e-calib with the Fédération Dentaire Internationale (FDI) criteria considering esthetic, functional and biological properties. In each moment of clinical assessment, standard digital photographs of each restoration were obtained. Two digital examiners (D1 and D2), equally calibrated and using the same criteria, evaluated all the images obtained in the clinical assessment. The data were analyzed with the calculation of Cohen Kappa coefficient, Kruskal-Wallis non-parametric test and Dunn\'s multiple shared test, with significance of 5%. Intra (same method) and inter (different methods) comparisons were realized. The results showed that agreement levels varied from \"Perfect\" to \"Fair\". There was a significant difference (p < 0.05) intra-examiners; between C1 and C2 to the marginal staining parameter; between D1 and D2 in the parameters surface luster, colour match and translucency, esthetic anatomical form and fracture of material and retention; inter-examiners was noticed significant difference in all the esthetic (surface luster, colour match and translucency, marginal staining, esthetic anatomical form) and functional properties (fracture of material and retention and marginal adaptation) observed. The association between the digital image to the clinical exam may be a promising tool associated with the clinical method to detect early failures in composite resin restorations, requiring further studies investigating the digital method.
147

The effect of filler on the mechanical properties of a novel resin-based calcium phosphate cement

Al Dehailan, Laila January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Several studies have found that resin-based amorphous calcium phosphate (ACP) composites can function well for applications that do not require high mechanical demand. Milled tricalcium phosphate (TCP), a new calcium-phosphate-releasing material, is crystalline in nature, suggesting it to be strong. In the present study, we investigated the use of a TCP-filled composite resin as a possible tooth restorative-material. An experimental TCP-based composite was prepared using monomer with a mixture of 34.3 percent by mass of EBPADMA, 34.2 percent by mass of HmDMA, and 30.5 percent by mass of HEMA. TCP fillers were added to the monomer mixture at different levels (30 percent, 40 percent, 50 percent, and 60 percent by weight). A universal testing machine (Sintech Renew 1121; Instron Engineering Corp., Canton, MA) was used to measure the compressive strength and modulus. FTIR was used to measure the degree of conversion. The depth of cure was determined according to the ISO standards for dental resin 4049 using the scrapping technique. Knoop hardness numbers were obtained by a microhardness tester (M-400; Leco Co., St. Joseph, MI). The viscosities of the experimental resin were determined in a viscometer (DV-II+ Viscometer; Brookfield, Middleboro, MA). The data were analyzed using a one-way analysis of variance (ANOVA). A 5-percent significance level was used for all the tests. Resin composites with 30-percent TCP filler showed the highest compressive strength and hardness values. Also, this group showed the lowest degree of conversion. Resin composites with 60-percent TCP filler showed the highest degree of conversion. However, this group showed the lowest compressive strength, depth of cure, and hardness. Resin composites with 50-percent filler showed the highest compressive modulus. Resin composites with 40-percent filler showed higher viscosity values than resin composites with 30-percent filler. In conclusion, increasing the filler level significantly reduced the compressive strength, hardness, and depth of cure, but increased the degree of conversion. Also, resin composites with the lowest filler level (30 percent) had the highest compressive strength, depth of cure, and hardness. From these results, it can be concluded that the experimental TCP-filled resin used in this study cannot be used as restorative material.
148

Evaluation of mechanical and fluoride ion release properties of a resin based restorative material, “Cention”

Hulsart, Line, Hongseethong, Chawanrat January 2022 (has links)
Background: A new permanent dental restorative material, Cention Forte, have recently been introduced. The manufacturer claims that this material has higher compressive strength than glass ionomer as well as positive ion release properties. Aim: To evaluate compressive strength, hardness and fluoride ion release properties of a new resin based dental restauration material, Cention Forte, in comparison with frequently used dental restoration materials.  Methods: Comparisons among Ceram.X Spectra ST (resin composite), GC Fuji II LC (glass ionomer) and Cention Forte (alkasite) were performed. Compression strength, Vickers hardness test and cumulative fluoride ion release for 2 days, 7 days in a pH4 water solution were tested. Results: Resin composites and Cention Forte showed no significant differences in compression strength, while glass ionomers showed a lower compression strength. The Vickers hardness test presented no significant difference between Cention Forte and the other two materials. Significant differences were found among the three materials in fluoride ion release. Resin composites released least amount of fluoride ions compared to Cention Forte and glass ionomer. After 2 days, Cention Forte release less fluoride than glass ionomer, but no differences in fluoride concentration after 7 days between these two materials.  Conclusions: Cention Forte showed equivalent mechanical properties to composite resin and comparable fluoride release property to glass ionomers.
149

Avaliação clínica randomizada de restaurações de classe II em dentes permanentes de ART e de resina composta / Randomized clinical trial of class II restorations of ART and composite resin in permanent teeth

Silva, Rafael Menezes 08 December 2017 (has links)
Este estudo avaliou a efetividade de restaurações de classe II por meio da técnica do Tratamento Restaurador Atraumático (ART), com retenções adicionais nas caixas proximais, em dentes permanentes, usando cimento de ionômero de vidro (CIV) de alta viscosidade, em comparação com restaurações convencionais de resina composta. Um exame epidemiológico foi realizado em uma população maior e representativa dos participantes da pesquisa. Cento e trinta e três participantes, de 8 a 28 anos, com boa saúde geral com uma a duas cavidades de classe II em dentes permanentes sem comprometimento pulpar e dor de dente foram incluídos neste estudo, com aprovação pelo Comitê de Ética sob o número: CAAE: 24012913.0.1001.5417. Foram feitas setenta e sete restaurações com cada material restaurador (Equia Fil-GC Corporation e Z350-3M). As restaurações foram avaliadas aos 6, 12 e 24 meses pelos critérios do ART e do Serviço de Saúde Pública dos Estados Unidos (USPHS) modificado. Correlação de Spearman e Regressão Linear Múltipla foram realizados entre as variáveis dor de dente, índice de placa visível (IPV), índice de sangramento gengival (ISG) e os índices CAST (The Caries Assessment Sprectrum and Treatment) e CPOD (contagem de dentes cariados, perdidos e restaurados) dos participantes do levantamento epidemiológico por meio do programa Statistica 7.1. Quanto à efetividade restauradora, os dados foram analisados, utilizando o programa SPSS 23.0, por meio dos testes de Mann-Whitnney, Qui-quadrado, Exato de Fisher, Qui-quadrado com tendência linear e Regressão logística pelo método Enter, quando pertinentes (p<0,050). O Teste de Kaplan-Meier avaliou as taxas de sobrevida das restaurações em relação ao critério do ART e USPHS modificado. O teste de Log-Rank comparou as curvas de sobrevida. Do índice CAST (1,53; 2,17) foi possível extrair o CPOD (0,58; 1,32) o qual apresentou menor especificidade e sensibilidade no registro da cárie. As taxas de sucesso para as restaurações de resina composta foram de 100% (6 meses), 98,7% (12 meses) e 91,5% (24 meses) para ambos os critérios de avaliação e para as restaurações de ART foram as mesmas para 6 meses (98,7%) e 12 meses (95,8%) e para 24 meses foram de 92% quando utilizado o critério do USPHS modificado e 90,3% quando utilizado o critério do ART, não sendo observada diferença estatística (p=0,466). As variáveis sexo, localidade, idade, CPOD, IPV, ISG, dor de dente, oclusão, contato proximal, tamanho da cavidade, anestesia e cooperação do paciente não apresentaram associação estatística com as taxas de sucesso das restaurações (p>0,050). Após 24 meses, as variáveis IPV e ISG não apresentaram odds ratio (OR) estatisticamente significante para as restaurações de ART (p>0,050). As restaurações de ART apresentaram uma sobrevida inferior pelo critério do ART (83,7%) quando comparado à sobrevida pelo critério do USPHS modificado (87,8%), após 24 meses (p=0,051). A sobrevida das restaurações de resina composta foi de 90,7% para ambos os critérios de avaliação. Conclui-se que não há diferença na taxa de sucesso de restaurações de classe II de ART com CIV de alta viscosidade, em dentes permanentes, com sulcos de retenção proximais, em comparação com restaurações de classe II de resina composta, após 24 meses. / This study evaluated the effectiveness of Class II restorations through the Atraumatic Restorative Treatment (ART) technique, with additional retentions in the proximal boxes, in permanent teeth, using high viscosity glass ionomer cement (HVGIC), as compared to restorations of composite resin. An epidemiological examination was conducted in a larger and representative population of the participants of study. One hundred and thirty three participants, aged 8 to 28 years, with good general health with 1 to 2 class II cavities in permanent teeth without pulp involvement and tooth pain were included in this study, with was approved by the Ethics Committee under the number: CAAE: 24012913.0.1001.5417. Seventy-seven restorations were made with each restorative material (Equia Fil-GC Corporation and Z350-3M). Restorations were evaluated at 6, 12, and 24 months by the criteria of ART and the modified United States Public Health Service (USPHS). Spearman Correlation and Multiple Linear Regression were performed between the variables tooth pain, visible plaque index (VPI), gingival bleeding index (GBI) and the CAST (The Caries Assessment Sprectrum and Treatment) and DMFT (Decayed, Missing and Filled teeth) obtained at the epidemiological survey using the Statistica program 7.1. As for restorative effectiveness, data were analyzed using the Mann-Whitnney, Chi-square, Fisher\'s Exact, Chi-square tests with linear trend and Logistic Regression by Enter method, where relevant (p<0.050). The Kaplan-Meier test evaluated the survival rates of the restorations in relation to the ART and modified USPHS criteria. The Log-Rank test compared the survival curves. From the CAST index (1.53; 2.17) it was possible to extract the DMFT (0.58; 1.32) which presented lower specificity and sensitivity in caries detection. The success rates for composite resin restorations were 100% (6 months), 98.7% (12 months) and 91.5% (24 months) for both assessment criteria and for ART restorations were the same for 6 months (98.7%) and 12 months (95.8%) and for 24 months were 92% when using the criteria of modified USPHS and 90.3% when using the criteria of ART, and no statistical difference was observed (p=0.466). The variables gender, locality, age, DMFT, VPI, GBI, toothache, occlusion, proximal contact, cavity size, anesthesia and cooperation of the participant did not present a statistical association with the success rates of the restorations (p>0.050). After 24 months, the VPI and GBI variables did not present a statistically significant odds ratio (OR) for ART restorations (p>0.050). ART restorations presented a lower survival rate by the criteria of ART (83.7%) when compared to the criteria of USPHS modified (87.8%), after 24 months (p=0.051). The survival of composite resin restorations was 90.7% for both evaluation criteria. It was concluded that there is no difference in the success rate of class II restorations of ART with HVGIC, in permanent teeth, with proximal retention grooves, compared to class II resin composite restorations, after 24 months.
150

Efeito da fonte de luz e enxaguatórios bucais na microdureza longitudinal de resinas compostas diretas. Análise complementar por espectroscopia Raman / Effect of the light curing units and mouthrise in the longitudinal microhardness of direct composite resins. Backing analysis for Ramam spectroscopy

Silva, Flaviane Renó Gonzaga 26 June 2009 (has links)
Neste estudo foi realizada avaliação longitudinal da microdureza Vickers e análise complementar do grau de conversão, de resinas compostas diretas, pelo método de espectroscopia Raman. As resinas compostas estudadas (M1: Charisma, M2: Z100 e M3: Filtek Supreme) foram fotopolimerizadas por diferentes fontes de luz (F1: Diodo emissor de F2: Luz e Halógena) e submetidos à ação de diferentes enxaguatórios bucais (S1: Saliva artificial, S2: Listerine e S3: Cepacol) e analisadas nas diferentes profundidades (P1 = 2mm, P2 = 4mm e P3 = 6mm). Para análise de microdureza Vickers - VHN (kg/cm3) foram confeccionados 07 corpos-de-prova (cp) para cada condição experimental (total = 180) por meio de matrizes em teflon, constituídas de dois dispositivos, o primeiro contendo uma cavidade de 02X04X06mm de base arredondada e um segundo dispositivo de superfície lisa que foi contraposto ao primeiro, as leituras foram realizadas 24 horas após a confecção dos cp por meio do microdurômetro Shimadzu HMV-200. A análise espectroscópica foi realizada por espectroscopia Raman (espalhamento Raman) (GC), para tal foram selecionadas aleatoriamente 06 amostras de cada resina estudada, das condições experimentais propostas (dentre as utilizadas para o teste de microdureza) e obtidos 06 cp para cada profundidade (total = 18 para cada resina), conforme metodologia preconizada pelo Laboratório do Departamento de Química da FFCLRP-USP. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar que para o fator Profundidade os valores de VHN e GC foram maiores para P1 e menores para P3 nas resinas R1 e R3; para o fator Fonte F2 determinou maiores valores de VHN para R1 e R2 e maiores valores de GC para todas as resinas analisadas; para o fator Solução S3 determinou maiores valores de VHN para todas as resinas, no entanto, não houve diferença no GC entre as Soluções; entre as resinas R2>R3>R1 para VHN e para DC R3>R1>R2. Logo, todos os fatores analisados influenciaram a microdureza e o grau de conversão das resinas. / In this study was made longitudinal evaluation of the microhardness Vickers and backing analysis of the conversion degree was accomplished, of direct composite resins, by the method of Raman spectroscopy. The composite resins studied (M1: Charisma, M2: Z100 and M3: Filtek Supreme) was photopolymerized by different sources of light (F1: light emitting diode and F2:quartz-tungsten-halogenous) and submitted to the action of different mouthrise (S1: Artificial saliva, S2: Listerine and S3: Cepacol) and analysed in the different depths (P1= 2mm, P2= 4mm e P3= 6mm). For analysis of microhardness Vickers - VHN (kg/cm3) were confectioned 07 samples for each experimental condition (total = 180) by means of matrix in teflon, constituted of two devices, first containing a socket of 02X04X06mm of rounded base and a second dispositive of smooth surface that was opposed to first, the readings were accomplished 24 hours after the confection of sample by means of the equipmente Shimadzu HMV-200. The spectroscopic analysis was accomplished by Raman spectroscopy (Raman scattering) (DC), for such 06 samples of each studied resin were selected randomly, of the experimental conditions proposals (amongst the used ones for the microhardness test) e obtained 06 samples for each depth (total=18 for each resin), as methodology praised for the Laboratory of the Department of Chemistry of the FFCLRP-USP. The obtained values were submitted to the analysis of variance (ANOVA) and, for the individual matchings, were accomplished the test of Tukey (p<0,05). The results had allowed to observe that for the factor Depth the values of VHN and DC were bigger for P1 and lesser for P3 in the resins R1 and R3; for the factor F2 Source it determined greaters values of VHN for R1 and R2 and greaters values of DC for all the analysed resins; for the factor S3 Solution it determined greaters values of VHN for all the resins, however, it did not have difference in the DC between the Solutions; between resins R2>R3>R1 for VHN and for DC R3>R1>R2. Soon, all the analysed factors had influenced the microhardness and the degree of conversion of resins.

Page generated in 0.0742 seconds