• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 36
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 365
  • 365
  • 365
  • 365
  • 282
  • 279
  • 247
  • 246
  • 56
  • 54
  • 53
  • 49
  • 49
  • 46
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

A influência da espessura óssea na medição da altura da borda alveolar em imagens de tomografia computadorizada de feixe cônico e espiral / The influence of bone thickness in alveolar bone height measure in CBCT and MSCT

Renato Barcellos Rédua 29 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Imagens de tomografia computadorizada (TC) permitem a visualização, sem distorções ou sobreposições, do complexo maxilo-facial, principalmente do osso alveolar. Estudos demonstraram boa reprodutibilidade e precisão da mensuração da altura da borda alveolar, todavia a influência da espessura óssea ainda é pouco descrita. Através da comparação com a mensuração direta, o objetivo deste estudo foi avaliar a precisão, reprodutibilidade e a influência da espessura óssea, na mensuração da altura da borda alveolar em imagens volumétricas e imagens bidimensionais multiplanares em TC de feixe cônico (TCFC) e em TC espiral (TCE). Utilizando 10 mandíbulas secas de humanos, 57 dentes anteriores foram tomografados em equipamentos iCAT (Imaging Science International, Hatfield, PA, EUA) e Brilliance 64 canais (Philips Eletronics, Eindhoven, Holanda), ambos utilizando voxels de 0,25 mm. Através de imagens volumétricas (3D) e imagens bidimensionais (2D) de cortes multiplanares, foi comparada a mensuração da altura da borda alveolar dessas imagens com a mensuração direta nas mandíbulas, feita por vestibular e lingual, por três avaliadores, com o auxílio de um paquímetro, totalizando 114 bordas alveolares medidas. Alta reprodutibilidade intra-avaliador (0,999 a 0,902) e interavaliador (0,998 e 0,868) foi observada através do índice de correlação intraclasse (ICC). Observou-se alta correlação entre a mensuração direta e indireta da altura da borda alveolar em imagens 2D, sendo r=0,923** e 0,916**, e em imagens 3D, com r=0,929** e 0,954*, em TCFC e TCE, respectivamente. Imagens 2D superestimam a altura da borda alveolar em 0,32 e 0,49 mm e imagens 3D em 0,34 e 0,30 mm, em TCFC e TCE respectivamente. Quando o osso alveolar apresenta espessura de no mínimo 0,6 mm a média da diferença entre medidas diretas e indiretas é de 0,16 e 0,28 mm em imagens 2D e de 0,12 e 0,03 mm em imagens 3D para TCFC e TCE respectivamente, sendo que 95% do limite de concordância varia de -0,46 a 0,79 mm e -0,32 a 0,88 mm em imagens 2D, e de -0,64 a 0,67 mm e -0,57 a 0,62 mm em imagens 3D, para TCFC e TCE respectivamente. Quando o osso alveolar é mais fino do que 0,6 mm a TC é imprecisa, pois 95% do limite de concordância variou de -1,74 a 5,42 mm e -1,64 a 5,42 mm em imagens 2D, e de -3,70 a 4,28 mm e -3,49 a 4,25 mm em imagens 3D, para TCFC e TCE respectivamente. Conclui-se que a mensuração da altura da borda alveolar através de imagens tomográficas apresenta alta reprodutibilidade, sendo que quando a borda alveolar apresenta pelo menos 0,6 mm, a precisão da mensuração é alta, todavia quando esta espessura é menor do que 0,6 mm a técnica é imprecisa. / Computerized tomogoraphy (CT) images allow for visualization, with no distortions or superimpostions, of the maxillo-facial complex, especially of the alveolar margins. Studies have demonstrated good reproducibility and precision of the alveolar bone height, however the influence of bone thickness is still scarcely described. The purpose of this study was, by comparing the direct measurement of alveolar bone height, to evaluate the precision, reproducibility and the influence of bone thickness on the same measurement in cone beam CT (CBCT) and spiral CT (SCT) volumetric and biplane images. Ten dry human mandibles, with a total of 57 anterior teeth were tomographed with an iCAT (Imaging Science International, Hatfield, PA, EUA) and a 64 channels Brilliance 64 tomograph (Philips Eletronics, Eindhoven, Holland), both using voxels of 0.25 mm. Alveolar bone height was measured on volumetric (3D) and bidimensional (2D) images of tomograms and compared with direct caliper measurements performed on the dry mandibles, on the buccal and lingual sides, by three raters in a total of 114 measurements. High intra-rater (0.999 a 0.902) and inter-rater (0.998 e 0.868) reproducibility was observed using the intraclass correlation coefficient (ICC). A high correlation was also observed between the direct and indirect measurements of alveolar bone height in 2D (r=0.923** e 0.916**), and 3D images (r=0.929** e 0.954*), for CBCT and SCT, respectively. Two-dimensional images overestimate alveolar bone height in 0.32 and 0.49 mm and 3D images in 0.34 and 0.30 mm, for CBCT and SCT, respectively. When alveolar bone thickness is at least 0.6 mm the mean difference is of 0.16 and 0.28 mm in 2D images and of 0.12 and 0.03 mm in 3D images for CBCT and SCT, respectively, with 95% limits of agreement ranging from -0.46 to 0.79 mm and -0.32 to 0.88 mm in 2D images, and of -0.64 to 0.67 mm and -0.57 to 0.62 mm in 3D images, for CBCT and SCT, respectively. When alveolar bone thickness is smaller than 0.6 mm CT evaluation is inaccurate, since 95% limits of agreement vary from -1.74 to 5.42 mm and -1.64 to 5.42 mm in 2D images, and from -3.70 to 4.28 mm and -3.49 to 4.25 mm on 3D images, for CBCT and SCT, respectively. It can be concluded that measurement of alveolar bone height on CT images presents high reproducibility. When alveolar bone thickness is greater than 0.6 mm measurement precision is high, and when this thickness is less than 0.6 mm the technique is inaccurate
352

Avaliação do seio maxilar e estruturas adjacentes em indivíduos edêntulos total ou parcial na região posterior da maxila / Evaluation of the maxillary sinus and adjacent structures in total or partial edentulous individuals in the posterior maxila

Angel Terrero Perez 03 April 2018 (has links)
Os seios maxilares são os maiores seios paranasais e seu desenvolvimento apresenta uma variabilidade entre os indivíduos, já que sofre um processo de expansão progressiva durante a vida toda, principalmente nos casos de perdas dentárias, provocando pneumatização do seio em direção ao rebordo alveolar, reduzindo sua altura. Quando essa altura óssea alveolar residual é insuficiente, uma cirurgia de levantamento de seio pode ser realizada para ganhar altura óssea e posterior instalação de implantes dentários. Em alguns casos, podem apresentar variações anatômicas, levando ao insucesso da técnica cirúrgica, por desconhecimento ou falta de planejamento através de exames complementares. Para evitar esse tipo de acidentes e complicações em implantodontia é preciso a ajuda de exames complementares para um melhor planejamento cirúrgico e protético, como é o caso da tomografia computadorizada de feixe cônico, que fornece imagens em três dimensões, possibilitando uma melhor avaliação do seio maxilar. Portanto, o objetivo deste estudo foi descrever as diferentes variações anatômicas apresentadas no seio maxilar em pacientes edêntulos total e parcial da região posterior da maxila, realizar mensurações do osso alveolar residual, paredes do seio e determinar a relação da artéria alveolar superior posterior com o seio maxilar, através da avaliação de tomografia computadorizada de feixe cônico disponíveis nos arquivos de imagens digitais do departamento de Cirurgia, Estomatologia, Patologia e Radiologia da Faculdade de Odontologia de Bauru da Universidade de São Paulo FOB/USP. / The maxillary sinus is the largest of the paranasal sinuses and its development presents a variability among the individuals, since it undergoes a process of progressive expansion during the whole life, mainly in the cases of dental losses, provoking pneumatization of the sinus toward the alveolar ridge, reducing your Height. When this residual alveolar bone height is insufficient, a sinus lift surgery can be performed to gain bone height and subsequent installation of dental implants. In some cases, they may present anatomic variations, leading to the failure of the surgical technique, due to lack of knowledge or lack of planning through complementary tests. To avoid such accidents and complications in implantology, it is necessary the help of complementary examinations for a better surgical and prosthetic planning, as is the case of conical beam CT, which provides images in three dimensions, allowing a better evaluation of the maxillary sinus. Therefore, the objective of this study was to describe the different anatomical variations presented in the maxillary sinus in total and partial edentulous patients of the posterior maxillary region, to perform measurements of the residual alveolar bone, sinus walls and to determine the relation of the posterior superior alveolar artery with the sinus maxillary, through the evaluation of conical beam computed tomography available in the digital images archives of the Department of Surgery, Stomatology, Pathology and Radiology of the Faculty of Dentistry of Bauru of the University of São Paulo FOB / USP.
353

Reabsorção radicular apical em decorrência do tratamento ortodôntico detectada por meio de tomografia computadorizada de feixe cônico / Apical root resorption due to orthodontic treatment detected by cone beam computed tomography

CASTRO, Iury Oliveira 17 February 2012 (has links)
Made available in DSpace on 2014-07-29T15:21:58Z (GMT). No. of bitstreams: 1 Dissertacao Iury Oliveira Castro.pdf: 1108480 bytes, checksum: 128afd0de2b97f12fc1f7b511b16af6f (MD5) Previous issue date: 2012-02-17 / Objective: To determine the frequency of apical root resorption in different tooth groups after the end of orthodontic treatment, detected by cone beam computed tomography. Methodology: Images of cone beam computed tomography of 30 patients who had Class I malocclusion and crowding were obtained before and after orthodontic movement. The treatment with fixed appliances was developed based on the Roth prescription. A total of 1256 dental roots were evaluated based on the measurement of linear length between root apex and incisal/cusp. It was an epidemiological, prospective, longitudinal and intra individual study. Results: The mean age of patients was 13 years, 11 were male and 19 female. One hundred percent of the patient presented teeth with apical root resorption, 46% of the roots avaluated was affected. The teeth showed higher extent of apical root resorption were upper lateral incisors, lower lateral, upper central, lower central, upper and lower first molars (p <0.05). By analyzing the roots individually, there was a high frequency of apical root resorption in maxillary central incisors (73%), maxillary lateral incisors (73%), mandibular central incisors (72%), mandibular lateral incisors (70%) and distal roots of mandibular first molar (63%). There was a low frequency of apical root resorption in the buccal roots of the maxillary second premolar (17%), distovestibular and palatine roots of maxillary second molar (18%) and distal roots of mandibular second molar (20%). The results showed that there was no association between frequency of resorption and gender (p> 0.05). The number of resorption did not vary with age when evaluated at age 11 to 16 years (p> 0.05). Conclusion: The apical root resorption was detected in 46% of the roots of teeth submitted to orthodontic treatment, diagnosed by cone beam computed tomography. The most affected teeth were central incisors, lateral and first molars. / Objetivo: Determinar a frequência de reabsorção radicular apical em diferentes grupos dentários após o término do tratamento ortodôntico identificada por meio de tomografia computadorizada de feixe cônico. Metodologia: Imagens de tomografia computadorizada de feixe cônico de 30 indivíduos, que apresentavam má oclusão Classe I e apinhamento, foram obtidas antes e depois da movimentação ortodôntica. O tratamento foi desenvolvido com aparelhos fixos com base na prescrição de Roth. Um total de 1256 raízes dentárias foram avaliadas com base na mensuração do comprimento linear entre ápices radiculares e incisais/cúspides. Resultados: A idade média dos pacientes foi de 13 anos, 11 eram do gênero masculino e 19 do feminino. Cem por cento dos pacientes apresentaram dentes com reabsorção radicular apical, com uma frequência de 46% de raízes afetadas. Os dentes que apresentaram maior extensão de reabsorção radicular apical foram incisivos laterais superiores, laterais inferiores, centrais superiores, centrais inferiores, primeiros molares superiores e inferiores (p < 0,05). Ao analisar as raízes individualmente verificou-se uma elevada frequência de reabsorção radicular apical em incisivos centrais superiores (73%), laterais superiores (73%), centrais inferiores (72%), laterais inferiores (70%) e raízes distais de primeiro molar inferior (63%). Verificou-se uma frequência baixa de reabsorção radicular apical em raízes vestibular do segundo pré-molar superior (17%), distovestibulares e palatinas de segundo molar superior (18%) e distal de segundo molar inferior (20%). Os resultados mostraram que não houve associação entre a frequência de reabsorção e gênero (p > 0,05). O número de reabsorção não variou com a idade quando avaliada a faixa etária de 11 a 16 anos (p > 0,05). Conclusão: A reabsorção radicular apical foi detectada em 46% das raízes de dentes submetidos a tratamento ortodôntico, por meio de tomografia computadorizada de feixe cônico. Os dentes mais afetados foram incisivos centrais, laterais e primeiros molares inferiores.
354

Avaliação de erros operatórios durante o preparo do canal radicular após o uso de instrumentos rotatórios de níquel-titânio realizados por estudantes e especialistas / Operative evaluation of errors during the preparation of root canal after the use of rotary instruments nickel-titanium made by students and specialists

OLIVEIRA, Henrique Cesar Marcal de 26 February 2010 (has links)
Made available in DSpace on 2014-07-29T15:22:00Z (GMT). No. of bitstreams: 1 dissertacao henrique c m oliveira.pdf: 1002486 bytes, checksum: eddcaf3f31b0f29703a16146f9f05b7d (MD5) Previous issue date: 2010-02-26 / The aim of this study was to determine the errors of procedures that occurred during the preparation of curved root canals after the use of instruments níqueltitânio powered motor managed by specialists in endodontics and dental students. Forty upper and lower molars of humans were randomly divided into two groups of 20, according to traders: G1A-(Molars, specialists in endodontics), G1B-(lower molars, specialists in endodontics), G2A-(molars, dental students), G2B-(lower molars, dental students). The ProTaper Universal System was used to prepare all root canals. The AH PlusTM associated with gutta-percha was used with lateral condensation technique for obturation of all canals. Periapical radiography and cone beam computed tomography (TCFC) were obtained to verify procedural errors occurred during the preparation of root canals. Two examiners evaluated all images for determining the presence or absence of instrument fracture, root perforation (cervical, middle or apical) and deviation original path of the root canal (apical transport). The data were statistically analyzed employing the Chi-square test. The significance level was 5%. The rate of fractured instruments showed no significant differences in the level of experience of operators (p = 1.000). Root perforations and transport apical occurred more frequently in the group of students, without significant differences. While there have been some procedural errors during root canal preparation with experienced and inexperienced operators, the results suggest that the introduction of tools of nickel-titanium engine-driven education / O objetivo deste estudo foi determinar os erros de procedimentos ocorridos durante o preparo de canais radiculares curvos após o uso de instrumentos de níqueltitânio acionados a motor manejados por especialistas em endodontia e estudantes de odontologia. Quarenta molares superiores e inferiores de humanos foram aleatoriamente divididos em dois grupos de 20, de acordo com os operadores: G1A- (molares superiores, especialistas em endodontia), G1B- (molares inferiores, especialistas em endodontia); G2A- (molares superiores, estudantes de odontologia), G2B- (molares inferiores, estudantes de odontologia). O sistema ProTaper Universal foi usado para o preparo de todos os canais radiculares. O cimento AH PlusTM associado com a guta-percha foi usado com a técnica da condensação lateral para a obturação de todos os canais radiculares. Radiografias periapicais e tomografia computadorizada de feixe cônico (TCFC) foram obtidas para verificar erros de procedimentos ocorridos durante o preparo dos canais radiculares. Dois examinadores avaliaram todas as imagens determinando a presença ou ausência de fratura de instrumentos, perfurações radiculares (terço cervical, médio ou apical) e desvio do trajeto original do canal radicular (transporte apical). Os dados foram estatisticamente avaliados empregando-se o teste Qui-quadrado. O nível de significância foi de 5%. A taxa de instrumentos fraturados não mostrou diferenças significantes em relação ao nível de experiência dos operadores (p=1,000). Perfurações radiculares e transportes apicais ocorreram mais frequentemente no grupo dos estudantes, sem diferenças significantes. Embora tenham sido observados alguns erros de procedimentos durante o preparo do canal radicular com operadores experientes e inexperientes, os resultados sugerem que a introdução de instrumentos de níquel-titânio movidos a motor no ensino da graduação parece promissora. Ambos os métodos de imagens permitiram identificar erros operatórios, porém a tomografia computadorizada de feixe cônico apresenta elevado potencial de auxiliar a terapia endodôntica.
355

Avaliação da presença de expansão basilar e de septos no seio esfenoidal humano por meio da tomografia computadorizada por feixe cônico / Assessment of the presence of basilar expansion and internal septa of the human sphenoidal sinus through cone beam computed tomography (CBCT)

Marcio Yara Buscatti 08 December 2009 (has links)
O seio esfenoidal humano, embora sua morfologia seja mais regular quando comparada à dos demais seios paranasais, apresenta numerosas variações anatômicas que afetam sua relação com estruturas vizinhas. Diversos autores mostram a importância do conhecimento dessas variações anatômicas, baseadas tanto na forma quanto na sua presença, para uma correta e segura abordagem cirúrgica nos procedimentos via endoscópica transesfenoidais. Devido a isso, o frequente estudo deste segmento anatômico se torna preponderante e para isso a tomografia computadorizada helicoidal, mais recentemente com o desenvolvimento da aquisição multislice, é de grande importância para o conhecimento tridimensional dos seus aspectos anatômicos e suas estruturas vizinhas, sendo hoje o exame indicado. A tomografia computadorizada por feixe cônico, devido ao baixo custo dos equipamentos e principalmente a baixa dose de radiação, aliada à qualidade e fidelidade de suas imagens, têm ocupado um espaço importante no diagnóstico por imagem nas diferentes especialidades da Odontologia e mostra-se também relevante sua ampliação em outras áreas em função das vantagens já citadas. O objetivo desse estudo, a partir da análise das imagens de 300 pacientes, obtidas em equipamento de tomografia computadorizada por feixe cônico, é mostrar a viabilidade da obtenção das mesmas para a avaliação das variações anatômicas do seio esfenoidal humano, no que se refere à presença e o tipo de expansão basilar e de septos, em um tomógrafo que une qualidade e fidelidade de imagens com baixa dose de radiação. Os resultados mostraram ser viável a observação, por meio da tomografia computadorizada por feixe cônico, tanto da presença de expansão basilar quanto de septos no seio esfenoidal humano, onde 69% dos exames analisados apresentaram expansão basilar e 60% septos. A presença de expansões mostrou ser independente em relação ao gênero e a idade e 81% delas apresentaram-se como críticas. A presença de septos mostrou ser também independente em relação ao gênero, porém associada a pacientes acima de 40 anos, sendo que 36% apresentaram somente o septo principal, 6% septos acessórios e 18% ambos. / The human sinus, although their morphology is more regular when compared to the other paranasal sinuses, has numerous anatomical variations that affect their relationship with neighboring structures. Several authors show the importance of anatomical variations knowledge, based on its shape and occurrence, for a correct and safe surgical approach in the endoscopic transsphenoidal procedures. Due to this, the frequent anatomic study becomes important and the helical CT, most recently with the development of multislice acquisition, is of great importance to the knowledge of their three-dimensional anatomy and its neighboring structures, being nowadays the main indicated survey. The cone beam computed tomography due to the its low cost of equipment and especially the low dose of radiation, combined with quality and fidelity of images, have occupied an important position in diagnostic imaging in the different specialties of Dentistry and shows to be also relevant in others areas according to the advantages already mentioned. This study, based on the analysis of obtained images from 300 patients in cone beam computed tomography equipment, intents the viability of obtaining the evaluation of anatomic variations of sphenoid sinus, in regard to the presence and type of basilar expansion and internal septa, in a CT scanner that combines quality and fidelity of images with low radiation dose. By means of cone-beam computed tomography the results showed the observation to be viable. The presence of basilar sinus expansion and septa in human sphenoid sinus were found. 69% of the analyzed cases showed basilar expansion and 60% the presence of septa. The presence of expansion was independent when considered the gender and age and 81% presented themselves as critical. The presence of septa was independent of gender and associated with patients over 40 years, and 36% had only primary septum, 6% accessories septa and 18% both.
356

Utilização de imagens tridimensionais da cavidade sinusal frontal provenientes de TCFC para determinar dimorfismo sexual entre indivíduos / Use of three-dimensional images of the frontal sinus cavity from CBCT to determine sexual dimorphism between individuals

Isabela Goulart Gil Choi 08 December 2016 (has links)
Foram poucos os estudos realizados para avaliar a capacidade da cavidade dos seios frontais para a diferenciação sexual. No entanto, a predição do sexo dos indivíduos é o passo mais importante para o desenvolvimento de um perfil biológico confiável durante a análise de restos esqueléticos. O advento da tomografia computadorizada por feixe cônico trouxe uma série de vantagens à clínica odontológica, e a quantidade de pacientes que realizam exames tomográficos para fins de diagnóstico tem aumentado cada vez mais permitindo com que estes dados sejam úteis para propósitos de identificação forense. Neste estudo, o objetivo foi propor uma nova metodologia para avaliar a capacidade de imagens em 3D da cavidade sinusal frontal, provenientes de tomografia computadorizada por feixe cônico, em determinar dimorfismo sexual entre os indivíduos. A amostra da pesquisa foi composta por 130 exames (65 do sexo masculino e 65 do sexo feminino) que foram segmentados e reconstruídos tridimensionalmente. O volume 3D foi exportado em formato Tiff nas normas frontal, lateral e basal. E as seguintes variáveis foram mensuradas em um segundo programa: área, perímetro, retângulo delimitador, elipse delimitadora, circularidade, razão de aspecto, arredondamento do objeto, solidez e diâmetro de Feret. O estudo foi capaz de demonstrar a existência de dimorfismo sexual com uma acurácia do modelo final de regressão logística igual a 80,0%. A norma basal foi a que garantiu maior poder de explicação na equação final. A metodologia foi validada e os resultados mostraram alto grau de confiabilidade. / There were few studies to assess the ability of the cavity of the frontal sinuses for sexual differentiation. However, the prediction of the sex of the individuals is the most important step in the development of a reliable biological profile during analysis of skeletal remains. The advent of cone beam computed tomography brought a number of advantages to the dental clinic, and the number of patients undergoing CT scans for diagnostic purposes has increased increasingly allowing that these data are useful for forensic identification purposes. The study aimed to propose a new methodology to assess the 3D images capacity of the frontal sinus cavity, from computed tomography cone beam, to attribute sexual dimorphism between individuals. The survey sample consisted of 130 exams (65 male and 65 female) who were reconstructed three-dimensionally. The 3D volume was exported in Tiff format in the frontal, side and basal views. In addition, the following variables were measured in a second program: area, perimeter, bounding rectangle, ellipse fit, circularity, aspect ratio, roundness, solidity and Feret\'s diameter. The study was able to demonstrate the existence of sexual dimorphism with an accuracy of the final logistic regression model equal to 80.0%. The basal view assured greater explanatory power in the final equation. The methodology has been validated and the results showed a high degree of reliability.
357

Tomografia computadorizada de feixe cônico como método de diagnóstico da espessura gengival e da distância da margem gengival à crista óssea / Cone-beam computed tomography as a diagnostic method for determination of gingival thickness and distance between gingival margin and bone crest

Borges, Germana Jayme 19 June 2013 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-27T15:07:23Z No. of bitstreams: 2 Tese - Germana Jayme Borges - 2013.pdf: 1472999 bytes, checksum: d3966b343549a12f4a7f7511fdeb6fa7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-28T11:38:50Z (GMT) No. of bitstreams: 2 Tese - Germana Jayme Borges - 2013.pdf: 1472999 bytes, checksum: d3966b343549a12f4a7f7511fdeb6fa7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-28T11:38:50Z (GMT). No. of bitstreams: 2 Tese - Germana Jayme Borges - 2013.pdf: 1472999 bytes, checksum: d3966b343549a12f4a7f7511fdeb6fa7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-06-19 / This study aimed to compare clinical measurements of gingival thickness (GT) and distance between gingival margin and vestibular (GMBC-V) and interproximal bone crests (GMBC-I) with those using cone-beam computed tomography (CBCT).Material and methods: GT and GMBC-V were measured in 348 teeth and GMBC-I, in 377 tooth regions of 29 patients with gummy smile. GT was assessed using transgingival probing (TP), ultrasound (US) and CBCT, whereas GMBC-V and GMBC-I, by trans-surgical clinical evaluation (TCE) and CBCT. Statistical analyses used independent t-test, Mann-Whitney test, ANOVA Tamhane‟s post hoc test, Pearson correlation coefficient and simple linear regression.Results: Significant difference was observed for GT: between TP, CBCT and US considering all teeth; between TP and CBCT and between TP and US in incisors and canines; between TP and US in premolars and molars. No significant difference was observed between TP and CBCT in premolarsand molars. TP presented the highest means for GT. Significant positive correlation and linear regression were observed (p < 0.05) between TP and CBCT, TP and US and CBCT and US. Significant difference was observed for GMBC-V and GMBC-I using TCE and CBCT, considering all teeth and groups of teeth. Pearson correlation and linear regression were significant for GMBC-V and GMBC-I (p < 0.05), except in molars(r = 0.014; p = 0.915) and region between molars(r = 0.239; p = 0.071).Conclusions:Measurements obtained using CBCT and US presented lower means for GT than TCE. GMBC-V and GMBC-I means were higher using CBCT than TCE. / Avaliar a TCFC como método de diagnóstico da espessura gengival (EG) e da distância da margem gengival à crista óssea vestibular(MGCO-V) e interproximal(MGCO-I), comparando mensurações clínicas com as medidas obtidas em imagens de TCFC.Material e métodos: o estudo foi desenvolvido em 29 pacientes com queixa de sorriso gengival e indicação de cirurgia para aumento de coroa clínica com finalidade estética. A EG e a MGCO-V foram mensuradas em 348 dentes e a MGCO-I em 377 regiões. A EG foi avaliada por meio de sondagem transgengival (ST), com aparelho de ultrassom (US) e nas imagens de TCFC, enquanto que a MGCO-V e MGCO-I foram verificadas por avaliação clínica transcirúrgica (ACT) e nas imagens de TCFC. Para padronizar o local de aferição foi utilizado um guia tomográfico e um guia clínico. A diferença entre as medidas de EG, MGCO-V e MGCO-I obtidas pelos diferentes métodos foi analisada pelo Teste-t independente, Mann-Whitney e ANOVA post hocTamhane, enquanto que a relação entre as mesmas foi avaliada pelo teste de Correlação de Pearson e Regressão Linear Simples. Resultados:para a EG foi observada diferença significante entre ST, TCFC e US quando considerados todos os dentes. No grupo dos incisivos e caninos houve diferença significativa entre ST e TCFC, e entre ST e US. Nos pré-molares e molares (M) não foi observada diferença entre ST e TCFC, mas houve entre ST e US. A ST registrou maiores médias de EG em relação aos demais métodos. Observou-se correlação e regressão linear positivas significativas (p< 0,05) entre ST e TCFC, ST e US e entre TCFC e US. Em relação à MGCO-V e MGCO-I, notou-se diferença significante entre as medidas obtidas por ACT e por TCFC, quando considerados todos os dentes e os grupos dentários. A análise de correlação e regressão linear foram significativas para MGCO-V e MGCO-I (p< 0,05) no grupo dos incisivos, caninos e pré-molares. Conclusão: A TCFC é um método de diagnóstico eficaz para visualização e mensuração da espessura gengival e distância da margem gengival à crista óssea, apresentando medidas correlacionadas às obtidas clinicamente e contribuindo dessa forma, para o planejamento de procedimentos estéticos em periodontia.
358

Análise tomográfica quantitativa linear de espessuras ósseas alveolares com vistas ao diagnóstico em ortodontia - Proposta de método / A quantitative linear tomographic analisys of the alveolar bone thicknesses and its implications to diagnosis in Orthodontics A method proposal

Siddhartha Uhrigshardt Silva 01 June 2012 (has links)
O objetivo principal desta pesquisa foi justificar a proposta de utilização de um novo método tomográfico (cone beam) de avaliação das espessuras ósseas alveolares, maxilares e mandibulares, por meio de testes objetivos das Condições de Repetitividade e de Precisão Intermediária associadas à variação intra e interoperadores, e conforme a utilização de programa computacional independente (AutoCAD®) para a realização das medições, aplicadas à sequência do Procedimento Operacional Padrão (POP) definido para este experimento. A Fase I da pesquisa registrou os critérios de obtenção da qualidade final das imagens tomográficas definitivas, a partir de equipamento iCAT® (Imaging Sciences International, Hatfield, Pa), com parâmetros de aquisição de 120KVp, 37,7mA e 26,9s, e considerando FOV cilíndrico de 13cm e matriz de 512x512 pixels. A resolução do voxel foi de 0,25mm; A Fase II registrou os critérios exploratórios relativos às condições operacionais do software de visualização, registro (inspeção e identificação) e medição das grandezas selecionadas. A Fase III registrou a realização dos testes de repetitividade e de reprodutibilidade das medidas. Um total de 72 grandezas lineares foram previamente definidas e metodologicamente testadas em sua qualidade de inspeção, identificação e medição, a partir da avaliação de sete (7) operadores independentes, cinco dos quais eram especialistas e com Mestrado Acadêmico em Ortodontia pela FOUSP e, o outro, especialista em Radiologia Odontológica e Doutor em Diagnóstico Bucal (FOUSP). Os examinadores foram previamente instruídos, calibrados e treinados considerando os requerimentos necessários à execução dos testes propostos. O protocolo de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da Universidade de São Paulo (Parecer CAAE 0120.0.017.000-11). A análise estatística dependeu da utilização de Modelo de Componentes de Variância (hierárquico), e foram consideradas como fontes de variação: as medidas, efetuadas por um mesmo operador ou por diferentes operadores; a face considerada, vestibular ou lingual/palatina; os locais (três níveis de espessura óssea alveolar) em cada uma das faces e, ainda, os diferentes dentes. Esta análise foi realizada de forma separada para mandíbula e maxila. Valores de p<0,05 indicaram significância estatística. Os resultados indicaram significativa confiabilidade geral no método proposto, considerando a Condição de Repetitividade, com apenas 0,24% da variabilidade maxilar total atribuível a um único operador, e mandibular de 0,53%; e com valores expressivos relativos às incertezas de medida maxilares (0,156mm) e mandibulares (0,091mm), desse modo atestando significativa consistência interna (repetibilidade) do método. Os testes da Condição de Precisão Intermediária também indicaram significativa confiabilidade geral no método proposto, com apenas 1,52% da variabilidade total mandibular atribuível à participação de diversos operadores, e maxilar de 0,25%; e com valores também expressivos relativos às incertezas de medida mandibulares (0,149mm) e maxilares (0,158mm), desse modo atestando significativa condição final de reprodutibilidade. Conclui-se que a utilização de imagens provenientes de tomógrafo iCAT®, conforme indicação de resolução de imagem com voxel de 0,25mm, em humanos vivos e a partir de cortes trans-axiais sistematicamente operacionalizados com auxílio de Software AutoCAD®, propicia a geração de condições metodológicas suficientemente favoráveis à obtenção de mapeamento quantitativo linear de espessuras ósseas alveolares, vestibulares e palatinas/linguais, tanto para a maxila quanto para a mandíbula. / This research aimed to justify the proposed use of a new tomography method (cone beam) in the clinical assessment of alveolar, maxillary and mandibular bone width, through objective tests of the Conditions of Repetitiveness and Intermediate Precision associated with intra- and inter-operator variation, using the independent computer program (AutoCAD®) for the execution of the measurements according to the Standard Operating Procedure (SOP) sequence defined for this experiment. Phase I of the research recorded the criteria for obtaining the final quality of the tomography images, using iCAT® (Imaging Sciences International, Hatfield, Pa, USA) equipment with acquisition parameters 120KVp, 37.7mA, and 26.9s, and considering cilindric field-of-view (FOV) of 13cm and 512x512 pixels matrix. The voxel resolution was 0.25mm. Phase II recorded the exploratory criteria relative to the operational conditions of the visualization software, registry (visual inspection and landmark identification) and measurement of the selected magnitudes. Phase III recorded the tests of repeatability and reproducibility of the measurements. A total of 72 linear magnitudes were previously defined and methodologically tested for their quality of inspection, identification and measurement, based on assessment by seven (7) independent operators, five of whom were specialists, with masters degrees in Orthodontics from FOUSP; and the other, a specialist in Dental Radiology and Doctor of Oral Diagnosis (FOUSP). The examiners were previously instructed, calibrated and trained according to the requirements for performing the proposed tests. The research protocol was approved by the Committee for Ethics in Research of the Faculty of Dentistry at the University of São Paulo (Protocol # 102/11-CAAE 0120.0.017.000-11). Statistical analysis used the (hierarchical) Components of Variation Model, and the sources of variation were considered to be: the measurements, made by the same operator or by different operators; the face considered, whether vestibular or lingual/palatal; the locations (three levels of alveolar bone thickness) in each of the faces and, also, the different teeth. This analysis was carried out separately for the mandible and the maxilla. Values of p<0.05 indicated statistical significance. The results indicated overall significant reliability in the proposed method considering the Condition of Repetitiveness, with only 0.24% of total maxillary, and 0.53% of mandibular, variability attributable to a single operator; and with expressive values relative to measurement uncertainties of maxillary (0.156 mm) and mandibular (0.091mm) averages, thereby attesting to significant internal consistency (\"repeatability\") of the method. Tests for the Condition of Intermediate Precision also indicated overall significant reliability of the proposed method, with only 1.52% total mandibular, and 0.25% maxillary, variability attributable to the participation of the various operators; and, also, with expressive values relative to measurement uncertainties of mandibular (0.149mm) and maxillary (0.158mm) averages, thereby attesting to the significant final condition of reproducibility. It is concluded that the use of images from iCAT® tomography, as indicated by image resolution with voxels of 0.25mm, in live humans and from transaxial cuts performed systematically with the help of AutoCAD® Software, provides methodological conditions sufficiently favorable for obtaining linear quantitative mapping of alveolar, vestibular and palatal/lingual bone thicknesses, for both the maxillary and mandibular dental arches.
359

Métodos de avaliação e mecanismos envolvidos no reparo apical e periapical após tratamento endodôntico em dentes com lesão induzida experimentalmente / Methods of evaluation and mechanisms involved in apical and periapical repair following root canal treatment in teeth with experimentally-induced apical periodontitis

Francisco Wanderley Garcia de Paula e Silva 13 October 2009 (has links)
Considerando-se a localização intra-óssea das lesões periapicais, o diagnostico clinico e dificultado e a avaliação radiográfica não fornece informações suficientes para o diagnostico de um periodonto apical sadio pós-tratamento. Dessa maneira, o objetivo deste estudo foi comparar os achados radiográficos e por tomografia computadorizada de feixe cônico com a avaliação microscópica após tratamento de canais radiculares em dentes de cães e avaliar a participação das metaloproteinases da matriz (MMPs) na lesão periapical e nos tecidos em processo de reparação, assim como em cistos e granulomas periapicais obtidos de humanos. A seguir, os mecanismos envolvidos na cementogênese apical foram investigados utilizando células do ligamento periodontal de humanos. Foram induzidas lesões periapicais em dentes de cães e o tratamento endodôntico foi realizado em sessão única ou apos utilização de um curativo de demora a base de hidróxido de cálcio [Ca(OH)2]. Avaliações radiográficas e tomográficas foram realizadas previamente, após a indução das lesões periapicais e 180 dias apos o tratamento endodôntico. Os tecidos periapicais foram avaliados por meio de microscopia de luz, imunofluorescência, imunoistoquímica e RT-PCR em tempo real. In vitro, células do ligamento periodontal foram utilizadas para avaliar os efeitos da estimulação com Ca(OH)2 nos processos de migração, proliferação, diferenciação celular e mineralização. As vias de sinalização envolvidas na diferenciação cementoblastica foram investigadas por meio de inibidores bioquímicos da via das proteínas quinases ativadoras de mitose (MAPK), bloqueadores de canais de cálcio e silenciadores de RNA para proteínas quinases reguladas por sinal extracelular (ERK-1 / ERK-2). De acordo com os resultados obtidos, a tomografia computadorizada permitiu a detecção de lesões periapicais com maior sensibilidade e acuracia que a radiografia periapical convencional, utilizando-se a avaliação microscópica como padrão-ouro. Histologicamente, as lesões periapicais experimentalmente induzidas apresentaram bactérias distribuídas pelo sistema de canais radiculares e lacunas de reabsorção do cemento e estavam associadas a desorganização das fibras colágenas e alta expressão de MMPs. A presença das MMPs em processos inflamatórios periapicais de humanos (cistos e granulomas) foi confirmada. Nos dentes com lesão periapical submetidos ao tratamento endodôntico em sessão única o desfecho do tratamento endodôntico foi caracterizado pela manutenção ou progressão da lesão periapical e alta expressão de MMPs. Por outro lado, nos dentes submetidos ao tratamento endodôntico utilizando o Ca(OH)2 como curativo de demora, maior numero de espécimes apresentaram regressão da lesão periapical e houve modulação da expressão de MMPs pelo tratamento. Neste grupo foi evidenciada neoformação de cemento no forame apical. Células do ligamento periodontal estimuladas com Ca(OH)2 expressaram proteínas especificas de cementoblastos (CEMP-1, CAP) e foram capazes de sintetizar nódulos de mineralização, mediados via ERK MAPK. A ação do Ca(OH)2 ocorreu via canais de cálcio, uma vez que o bloqueio destes canais inibiu a fosforização de ERK-1 e ERK-2 e, portanto, a expressão de CEMP-1 e CAP. CEMP-1 estimulou a migração, proliferação e mineralização mediada por células, exercendo um papel central na cementogenese, uma vez que o bloqueio de CEMP-1 inibiu a migração celular e mineralização. Juntos, estes resultados permitem concluir que a tomografia computadorizada e superior a radiografia periapical convencional para detecção de lesões periapicais refratarias ao tratamento de canais radiculares. Ainda, o tratamento endodôntico realizado utilizando o hidróxido de cálcio como curativo de demora propiciou um reparo apical e periapical mais favorável do que o tratamento endodôntico em sessão única, possivelmente devido a capacidade do Ca(OH)2 induzir a diferenciação de células do ligamento em células com um fenótipo cementoblastico e posterior mineralização. / Clinical diagnosis of apical periodontitis is difficult due to the intraosseous nature of the disease and radiographic evaluation does not provide sufficient information to determine a healthy apical periodontium following root canal therapy. Therefore, the aim of this study was to compare the radiographic and cone beam computed tomographic findings with microscopic evaluation following root canal treatment in dogs teeth. Then, the presence of matrix metalloproteinases (MMPs) in apical periodontitis and during the healing phase following treatment was evaluated and compared to the expression of MMPs in periapical cysts and granulomas obtained from human. Finally, the mechanisms involved in apical cementogenesis were investigated using human periodontal ligament cells. Apical periodontitis was induced in dogs teeth and then root canal treatment was performed in a single visit or using calcium hydroxide [Ca(OH)2] as the root canal dressing. Tomographic and radiographic evaluations were performed prior to and following induction of apical periodontitis, and 180 days following root canal therapy. Periapical tissues were evaluated by conventional light microscopy, immunofluorescence, immunohistochemistry, and real time RT-PCR. In vitro, periodontal ligament cells were used to evaluate the effects of Ca(OH)2 treatment on cell migration, proliferation, differentiation, and mineralization. The signaling pathways triggered by treatment with Ca(OH)2 were investigated using mitogen activated protein kinase (MAPK) biochemical inhibitors, calcium channel blockers, and extracellular regulated protein kinase (ERK-1 / ERK-2) silencing RNAs. Based on the results obtained, apical periodontitis was detected with higher sensitivity and accuracy by means of cone beam computed tomography compared to conventional periapical radiographs, using microscopic evaluation as the gold standard. Histological evaluation revealed that teeth with apical periodontitis presented microorganisms throughout the root canal system and in areas with resorption of cementum. Apical periodontitis was characterized by collagen fiber disorganization and high expression of MMPs. The presence and activity of MMPs was confirmed in periapical inflammatory diseases (cysts and granulomas) obtained from humans. Root canal treatment outcome was characterized by maintenance or progression of apical periodontitis and high expression of MMPs in teeth submitted to root canal treatment in a single visit, whereas root canal treatment outcome in teeth submitted to root canal treatment using Ca(OH)2 as the root canal dressing, higher number of teeth presented reduced apical periodontitis and lower expression of MMPs. In this group, cementum neogenesis was evident in the apical foramina. Periodontal ligament cells stimulated with Ca(OH)2 expressed cementoblastic specific proteins (CEMP-1, CAP) and were able to synthesize mineralized nodules via ERK MAPK. The effects of Ca(OH)2 occurred via calcium channels, since their blockade prevented ERK-1 and ERK-2 phosphorylation and therefore expression of CEMP-1 and CAP. CEMP-1 stimulated cell migration, proliferation, and mineralization and it was central to cementogenesis because blockade of activity of CEMP-1 prevented cell migration and mineralization. Taken together, these findings demonstrate that cone beam computed tomography is superior to conventional periapical radiography for detection of refractory apical periodontitis. Furthermore, the root canal treatment using Ca(OH)2 as the root canal dressing permitted a more favorable outcome than the root canal treatment performed in a single visit, probably due to the ability of Ca(OH)2 induce cementoblastic differentiation of periodontal ligament cells and mineralization.
360

Manejo clínico de una reabsorción apical con ápice abierto y uso del cemento biocerámico NeoMta™ Plus ® / Clinical management of an apical resorption with the use of bioceramic NeoMta ™ Plus ®

Melgarejo Cabello , Jhocelyn Carmen 19 October 2020 (has links)
La reabsorción radicular es el proceso de eliminación de cemento y / o dentina a través de la actividad fisiológica o patológica. La reabsorción radicular patológica puede ocurrir en asociación con varias afecciones como el trauma, reimplantación, terapia de ortodoncia, erupción tardía e irregular de dientes o tumores y quistes en expansión. La reabsorción radicular localizada en un diente asociado a una lesión apical crónica de origen inflamatorio pos-trauma, podría ocasionar un ápice abierto. Es importante establecer un correcto diagnóstico, plan de tratamiento y controles para estos casos. El tratamiento indicado para un diente con ápice abierto, lesión apical crónica de origen inflamatorio pos-trauma, es realizar un tope apical para evitar la extrusión de las soluciones de irrigantes y los materiales de relleno hacia la zona periapical. En la actualidad el uso de los cementos biocerámicos es recomendado para realizar topes apicales mostrando excelentes resultados en biocompatibilidad y micro-dureza; existiendo diferentes cementos biocerámicos para conseguir tal propósito. El objetivo de este reporte de caso es presentar el manejo clínico de una reabsorción con ápice abierto realizando un tope apical con el cemento biocerámico NeoMta ™ Plus ®. / Root resorption is the process of separating cement and / or dentin through physiological or pathological activity. Pathological root resorption can result in association with various conditions such as trauma, reimplantation, orthodontic therapy, late and irregular eruption of teeth, or expanding tumors and cysts. Localized root resorption in a tooth associated with a chronic apical lesion of inflammatory origin after trauma, could cause an open apex. It is important to establish a correct diagnosis, treatment plan and controls for these cases. The treatment indicated for a tooth with an open apex, chronic apical lesion of inflammatory origin after trauma, an apical stop is made to avoid the extrusion of irrigant solutions and filling materials into the periapical area. Currently, the use of bioceramic cements is recommended to make apical stops showing excellent results in biocompatibility and micro-hardness; there are different bioceramic cements to achieve this purpose. The objective of this case report is to present the clinical management of an open apex resorption by executing an apical stop with the NeoMta ™ Plus ® bioceramic cement. / Trabajo académico

Page generated in 0.1126 seconds