• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 36
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 365
  • 365
  • 365
  • 365
  • 282
  • 279
  • 247
  • 246
  • 56
  • 54
  • 53
  • 49
  • 49
  • 46
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação tridimensional da sínfise mandibular em crânios secos e sua associação com diferentes classificações de tipos faciais / Three-dimensional evaluation of mandibular symphysis in dry skulls and their association with different classifications of facial types

Fernanda Catharino Menezes Franco 12 February 2014 (has links)
O objetivo deste trabalho foi desenvolver um estudo morfológico quantitativo e qualitativo da região da sínfise mandibular (SM), através da construção de modelos tridimensionais (3D) e avaliar o seu grau de associação com diferentes classificações de padrões faciais. Foram avaliados 61 crânios secos humanos de adultos jovens com oclusão normal, com idade entre 18 e 45 anos e dentadura completa. Tomografias computadorizadas de feixe cônico (TCFC) de todos os crânios foram obtidas de forma padronizada. O padrão facial foi determinado por método antropométrico e cefalométrico. Utilizando o critério antropométrico, tomando como referência o índice facial (IF), o padrão facial foi classificado em: euriprósopo (≤84,9), mesoprósopo (85,0 - 89,9) e leptoprósopo (≥90,0). Pelo critério cefalométrico, o plano mandibular (FMA) determinou o padrão facial em curto (≤21,0), médio (21,1 - 29,0) e longo (≥29,1); e o índice de altura facial (IAF) classificou a face em hipodivergente (≥0,750), normal (0,749 - 0,650) e hiperdivergente (≤0,649). A construção de modelos 3D, representativos da região da SM, foi realizada com o auxílio do software ITK-SNAP. Os dentes presentes nesta região, incisivos, caninos e pré-molares inferiores, foram separados do modelo por técnica de segmentação semi-automática, seguida de refinamento manual. Em seguida, foram obtidos modelos 3D somente com o tecido ósseo, possibilitando a mensuraçãodo volume ósseo em mm3 (VOL) e da densidade radiográfica, pela média de intensidade dos voxels (Mvox). No programa Geomagic Studio 10 foi feita uma superposição anatômica dos modelos 3D em bestfit para estabelecer um plano de corte padronizado na linha média. Para cada sínfise foi medida a altura (Alt), a largura (Larg) e calculado o índice de proporção entre altura e largura (PAL). A avaliação da presença de defeitos alveolares foi feita diretamente na mandíbula,obtendo-se a média de todas as alturas ósseas alveolares (AltOss) e a média da dimensão das deiscências presentes (Medef). O índice de correlação intra-classe (ICC) com valores entre 0,923 a 0,994,indicou alta reprodutibilidade e confiabilidade das variáveis medidas. As diferenças entre os grupos, determinados pelas classificações do padrão facial (IF, FMA e IAF), foram avaliadas através da análise de variância (oneway ANOVA) seguida do teste post-hoc de Tukey. O grau de associação entre o padrão facial e as variáveis Vol, Mvox, PAL, Alt, Larg, AltOss e Medef foi avaliado pelo coeficiente de correlação de Pearson com um teste t para r. Os resultados indicaram ausência de diferença ou associação entre o volume, densidade radiográfica e presença de defeitos alveolares da SM e o padrão facial quando determinado pelo IF, FMA e IAF. Verificou-se tendência de SM mais longas nos indivíduos com face alongada, porém a largura não mostrou associação com o padrão facial. Estes resultados sugerem que as classificações utilizadas para determinar o padrão facial não representam satisfatoriamente o caráter 3D da face humana e não estão associadas com a morfologia da SM. / The objective of this study was to develop a quantitative and qualitative morphological study of the mandibular symphysis (SM) region through the construction of three-dimensional models (3D) and assess their association with different classifications of facial patterns. Sixty-one human dry skulls of young adults with normal occlusion, aged 18 and 45, with complete dentition, were evaluated. Cone beam computed tomography (CBCT) of all skulls were obtained in a standard manner. The facial pattern was determined by anthropometric and cephalometric methods. By the anthropometric criteria, using as reference the facial index (IF), facial patterns were classified as: euriprosopic (≤ 84.9), mesoprosopic (85.0 to 89.9) and leptoprosopic (≥ 90.0). By the cephalometric criteria, the mandibular plane (FMA) determined the facial pattern as short (≤ 21.0), medium (21.1 to 29.0) and long (≥ 29.1), and the facial height index (IAF) determined the classification of the face in hypodivergent (≥ 0.750), average (0.749 to 0.650) and hyperdivergent (≤ 0.649). Data obtained were reconstructed using ITK-SNAP software. Teeth present in this region, incisors, canines and premolars, were separated from the model by semi-automatic segmentation, followed by manual refinement. Then the 3D models were obtained only with bone tissue, enabling the measurement of bone volume in mm3 (VOL) and radiographic density, by the mean intensity of the voxels (MVox). With the Geomagic Studio 10 software an anatomical best fit superimposition of 3D models was performed to standardly cut in the midline. For each symphysis the height (Alt) and width (Larg) were measured, and the ratio between height and width was calculated (PAL). The evaluation of the presence of alveolar defects was done directly on the mandible, thus obtaining the average of all the alveolar bone height (AltOss) and the average of the size of the present dehiscences (Medef). The intra-class correlation index (ICC) showed values between 0.923 to 0.994, indicating high reproducibility and reliability of the measurements. The differences between the groups as determined by the facial pattern (IF, FMA and LAI) ratings were assessed by analysis of variance (one way ANOVA) followed by post-hoc Tukey test. The degree of association between facial pattern and Vol, MVox, PAL, Alt, Larg, AltOss and Medef variables was assessed by Pearson's correlation coefficient with a t-test for r. The results indicated no difference or association between the volume, density and presence of radiographic alveolar defects of the SM and the facial pattern when determined by IF, FMA and IAF. There was a tendency of a longer SM in individuals with longer faces, but the width was not associated with the facial pattern. These results suggest that the classifications used to determine the facial pattern does not represent the 3D nature of the human face and are not associated with the morphology of the SM.
82

Tomografia computadorizada de feixe cônico para avaliação do tratamento da classe II divisão 1ª com o aparelho Herbst no espaço aéreo faríngeo

Palomino-Gómez, Sandra Patricia [UNESP] 17 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-17Bitstream added on 2014-06-13T19:56:54Z : No. of bitstreams: 1 gomez_spp_me_arafo.pdf: 720577 bytes, checksum: f32f19712e837651d99f8642d99cbf3c (MD5) / As mudanças nos padrões de respiração nasal afetam profundamente o crescimento craniofacial. Avanços tecnológicos, como a tomografia computadorizada de feixe cônico (TCFC), têm sido utilizados com o propósito de se observar tridimensionalmente, o crânio, a face e o espaço aéreo faríngeo, sendo possível a avaliação das mudanças do espaço aéreo induzidas pelos aparelhos ortopédicos propulsores mandibular. O intuito deste estudo é apresentar um método de avaliação das vias aéreas de fácil reprodutibilidade, e avaliar, mediante a TCFC, os efeitos do aparelho de Herbst bandado no espaço aéreo orofaríngeo (EAOF), nasofaríngeo (EANF) e faríngeo superior (EAFS), em indivíduos com má oclusão classe II divisão 1ª. A amostra foi composta por imagens digitais de 15 indivíduos (idade média inicial de 15,7 anos ± 1.7, após surto de crescimento pubertário) com má oclusão classe II divisão 1ª, tratados com aparelho Herbst bandado (8 meses). Os exames tomográficos foram realizados antes (T1) e após (T2) o tratamento. A fase inicial foi realizada com a orientação do nos planos; axial, coronal e sagital. Foram mensurados: comprimento no software Dolphin 3D ®: comprimento, maior área no corte coronal, maior área no corte sagital, área mínima da secção transversal e volume, de EANF, EAOR e EAFS (orofaringe e nasofaringe). Dois avaliadores previamente calibrados mensuraram duas vezes apenas um tempo das tomografias, para observar a reprodutibilidade (inter-examinador) e replicabilidade (intra-examinador). Sendo confirmada a reprodutibilidade do método, foi avaliado o efeito do aparelho Herbst, analisando os períodos pré (T1) e pós (T2) tratamento ortopédico. A análise estatística dos dados foi realizada em duas etapas. Primeira etapa, a confiabilidade das medidas apresentaram boa replicabilidade (intra-examinador)... / Changes in nasal breathing patterns profoundly affects the craniofacial growth. Technological advances, such as cone beam computed tomography (CBCT), have been used in order to observe three-dimensionally: the skull, face and pharyngeal airway space, with possible assessment of airspace changes induced by orthopedic activators. The purposes of this study are to present a method for assessing airway that is easily reproducted, and evaluate through the CBCT the effects of banded Herbst appliance in the oropharyngeal airspace (EAOF), nasopharyngeal (EANF) and upper pharynx (EAFS) in individuals with malocclusion class II division 1. The sample consisted of digital images of 15 individuals (initial age of 15.7 years ± 1.7, after pubertal growth spurt) with malocclusion class II division 1, treated with banded Herbst appliance (8 months). CBCT scans were performed before (T1) and after (T2) treatment. The initial phase was conducted with the guidance of planes: axial, coronal and sagittal. The following were measured: the largest area in the coronal and sagittal, minimum cross-sectional area and volume of EANF, and EAOR EAFS (oropharynx and nasopharynx) by length in Dolphin 3D® software. Two calibrated evaluator mesured twice time of CBCT to observe the reproducibility (inter-examiner) and repeatability (intra-examiner). Once the reproductability of the method was coinfirmed, the effect of the Herbst applicance was evaluated before (T1) and after (T2) the orthodontic treatment. The statistical analysis was performed in two steps. First step, the reliability of the measurements showed good repeatability (intra-examiner) (ICC ≥ 0.984) and good reproducibility (inter-examiner) (ICC ≥ 0.911) for all measures except the minimum area of cross section of all regions, which showed variability. Second step, once confirmed the reliability of the measuremens, Student t test was appleid, significance... (Complete abstract click electronic access below)
83

Avaliação dimensional do espaço aéreo faríngeo em crianças com diferentes morfologias faciais por meio da tomografia computadorizada do feixe cônico

Zinsly, Sabrina dos Reis [UNESP] 28 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-28Bitstream added on 2014-06-13T19:38:18Z : No. of bitstreams: 1 zinsly_sr_me_sjc.pdf: 1840664 bytes, checksum: 9af5fca2a2307f238c9eaee02ad4e681 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste estudo foi avaliar as diferenças no espaço aéreo faríngeo em crianças com diferentes padrões faciais. Foram avaliadas as tomografias computadorizadas de feixe cônico de 98 indivíduos em crescimento, com idade média de 8,9 anos, divididas por sexo e faixa etária, e subdivididas de acordo com o padrão de crescimento (horizontal, vertical normal e produtores) e tipo de má oclusão (Classe I e Classe II). Utilizando um programa tridimensional, foram analisados o volume, área sagital, menor área de seção transversal e as dimensões ântero-posteriores da faringe superior e inferior. As dimensões ântero-posterior da faringe superior e inferior foi significativamente menor em indivíduos com Classe II em crianças na faixa etária entre 9 a 11 anos e a faringe superior em foi significativamente menor em crianças na faixa etária entre 5 e 7 anos com padrão de crescimento vertical. Porém, quando a faringe foi avaliada tridimensionalmente, não foram encontradas diferenças nas demais dimensões sugerindo que diferenças no padrão vertical e no tipo de má oclusão ântero-posterior (Classe I e II) não influenciam as dimensões da faringe. Não foi encontrado dimorfismo sexual. A região de maior constrição da faringe esteve presente mais freqüentemente na orofaringe (86%). Embora as dimensões lineares possam variar entre os diferentes padrões faciais, quando avaliadas tridimensionalmente, elas não foram influenciadas pelas diferentes morfologias faciais / The aim of this study was to assess the differences in pharyngeal airway space in children with different facial patterns. Cone-beam computed tomography records of 98 growing patients with mean age of 8.9 years divided by sex and age groups and subdivided according to growth pattern (horizontal, normal and vertical growers) and type of malloclusion (Class I and Class II) were evaluated .Using a 3-dimensional virtual program the volume, sagital area, smallest cross section area, anteroposterior dimensions of superior and inferior pharynx were obtained. The anteroposterior linear dimensions of superior and inferior pharynx in children with 9 to11 years was significant smaller in patients with Class II relationship but in 3D evaluation differences were not found suggesting that anteroposterior malocclusion do not influence pharynx dimensions. The anteroposterior linear dimensions of superior , pharynx in children with 5 to7 years was significant smaller in patients with vertical growth pattern when compared to normal growers, but in 3D evaluation differences were not found suggesting that vertical pattern do not influence pharynx dimensions. No sexual dimorphism was found. The most constricted region of pharynx were mostly found at oropharynx(96%).Although linear dimensions can vary among different facial patterns, the 3-dimensional dimensions weren’t influenced by different facial morphologies
84

Avaliação tridimensional da sínfise mandibular em crânios secos e sua associação com diferentes classificações de tipos faciais / Three-dimensional evaluation of mandibular symphysis in dry skulls and their association with different classifications of facial types

Fernanda Catharino Menezes Franco 12 February 2014 (has links)
O objetivo deste trabalho foi desenvolver um estudo morfológico quantitativo e qualitativo da região da sínfise mandibular (SM), através da construção de modelos tridimensionais (3D) e avaliar o seu grau de associação com diferentes classificações de padrões faciais. Foram avaliados 61 crânios secos humanos de adultos jovens com oclusão normal, com idade entre 18 e 45 anos e dentadura completa. Tomografias computadorizadas de feixe cônico (TCFC) de todos os crânios foram obtidas de forma padronizada. O padrão facial foi determinado por método antropométrico e cefalométrico. Utilizando o critério antropométrico, tomando como referência o índice facial (IF), o padrão facial foi classificado em: euriprósopo (≤84,9), mesoprósopo (85,0 - 89,9) e leptoprósopo (≥90,0). Pelo critério cefalométrico, o plano mandibular (FMA) determinou o padrão facial em curto (≤21,0), médio (21,1 - 29,0) e longo (≥29,1); e o índice de altura facial (IAF) classificou a face em hipodivergente (≥0,750), normal (0,749 - 0,650) e hiperdivergente (≤0,649). A construção de modelos 3D, representativos da região da SM, foi realizada com o auxílio do software ITK-SNAP. Os dentes presentes nesta região, incisivos, caninos e pré-molares inferiores, foram separados do modelo por técnica de segmentação semi-automática, seguida de refinamento manual. Em seguida, foram obtidos modelos 3D somente com o tecido ósseo, possibilitando a mensuraçãodo volume ósseo em mm3 (VOL) e da densidade radiográfica, pela média de intensidade dos voxels (Mvox). No programa Geomagic Studio 10 foi feita uma superposição anatômica dos modelos 3D em bestfit para estabelecer um plano de corte padronizado na linha média. Para cada sínfise foi medida a altura (Alt), a largura (Larg) e calculado o índice de proporção entre altura e largura (PAL). A avaliação da presença de defeitos alveolares foi feita diretamente na mandíbula,obtendo-se a média de todas as alturas ósseas alveolares (AltOss) e a média da dimensão das deiscências presentes (Medef). O índice de correlação intra-classe (ICC) com valores entre 0,923 a 0,994,indicou alta reprodutibilidade e confiabilidade das variáveis medidas. As diferenças entre os grupos, determinados pelas classificações do padrão facial (IF, FMA e IAF), foram avaliadas através da análise de variância (oneway ANOVA) seguida do teste post-hoc de Tukey. O grau de associação entre o padrão facial e as variáveis Vol, Mvox, PAL, Alt, Larg, AltOss e Medef foi avaliado pelo coeficiente de correlação de Pearson com um teste t para r. Os resultados indicaram ausência de diferença ou associação entre o volume, densidade radiográfica e presença de defeitos alveolares da SM e o padrão facial quando determinado pelo IF, FMA e IAF. Verificou-se tendência de SM mais longas nos indivíduos com face alongada, porém a largura não mostrou associação com o padrão facial. Estes resultados sugerem que as classificações utilizadas para determinar o padrão facial não representam satisfatoriamente o caráter 3D da face humana e não estão associadas com a morfologia da SM. / The objective of this study was to develop a quantitative and qualitative morphological study of the mandibular symphysis (SM) region through the construction of three-dimensional models (3D) and assess their association with different classifications of facial patterns. Sixty-one human dry skulls of young adults with normal occlusion, aged 18 and 45, with complete dentition, were evaluated. Cone beam computed tomography (CBCT) of all skulls were obtained in a standard manner. The facial pattern was determined by anthropometric and cephalometric methods. By the anthropometric criteria, using as reference the facial index (IF), facial patterns were classified as: euriprosopic (≤ 84.9), mesoprosopic (85.0 to 89.9) and leptoprosopic (≥ 90.0). By the cephalometric criteria, the mandibular plane (FMA) determined the facial pattern as short (≤ 21.0), medium (21.1 to 29.0) and long (≥ 29.1), and the facial height index (IAF) determined the classification of the face in hypodivergent (≥ 0.750), average (0.749 to 0.650) and hyperdivergent (≤ 0.649). Data obtained were reconstructed using ITK-SNAP software. Teeth present in this region, incisors, canines and premolars, were separated from the model by semi-automatic segmentation, followed by manual refinement. Then the 3D models were obtained only with bone tissue, enabling the measurement of bone volume in mm3 (VOL) and radiographic density, by the mean intensity of the voxels (MVox). With the Geomagic Studio 10 software an anatomical best fit superimposition of 3D models was performed to standardly cut in the midline. For each symphysis the height (Alt) and width (Larg) were measured, and the ratio between height and width was calculated (PAL). The evaluation of the presence of alveolar defects was done directly on the mandible, thus obtaining the average of all the alveolar bone height (AltOss) and the average of the size of the present dehiscences (Medef). The intra-class correlation index (ICC) showed values between 0.923 to 0.994, indicating high reproducibility and reliability of the measurements. The differences between the groups as determined by the facial pattern (IF, FMA and LAI) ratings were assessed by analysis of variance (one way ANOVA) followed by post-hoc Tukey test. The degree of association between facial pattern and Vol, MVox, PAL, Alt, Larg, AltOss and Medef variables was assessed by Pearson's correlation coefficient with a t-test for r. The results indicated no difference or association between the volume, density and presence of radiographic alveolar defects of the SM and the facial pattern when determined by IF, FMA and IAF. There was a tendency of a longer SM in individuals with longer faces, but the width was not associated with the facial pattern. These results suggest that the classifications used to determine the facial pattern does not represent the 3D nature of the human face and are not associated with the morphology of the SM.
85

Avaliação da anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico em uma população brasileira / Evaluation of mandibular anatomy and its variations by cone beam computed tomography in a brazilian population

Cunha, Rodrigo Montezano da January 2016 (has links)
O conhecimento da localização, bem como da configuração das estruturas anatômicas presentes na mandíbula e suas respectivas variações são extremamente importantes para o planejamento de procedimentos cirúrgicos que envolvam este osso. O presente estudo teve como objetivo avaliar a anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico (TCFC) em uma população brasileira. Foram utilizados 1254 exames de TCFC realizados no equipamento I-Cat Next Generation, (Imaging Sciences International®) sob um protocolo com voxel de 0,2 mm, FOV amplo (16cm x 13cm) e tempo de escaneamento de 40 segundos. Três examinadores treinados e calibrados avaliaram os exames por meio do software I-Cat Vision (Imaging Sciences International®). Os dados que foram coletados em um formulário Access (Microsoft® Office) e analisados para prevalência, também foram correlacionados, isolando as variáveis gênero e situação dentária (dentado total, dentado parcial e desdentado total. Os resultados de prevalência foram: forame mentual localizado entre o 1º e 2º pré-molar inferior (91,38%), alça anterior (12,57%), canais acessórios (40%), canal mandibular bífido (CMB) (22%) e canal mandibular corticalizado (33,84%). O canal mandibular, em toda sua extensão, está localizado mais para vestibular nas mulheres, com diferença estatisticamente significante entre gêneros (P=0,002). Não foi encontrada diferença na distância V-L na região de fóvea submandibular entre os gêneros. Os CMBs não tem predileção por gênero (P=0,186), havendo diferença estatisticamente significante entre os tipos (P=0,001), sendo o Retromolar o mais frequente. O uso dos exames de TCFC permitiu identificar características anatômicas mandibulares importantes em uma população brasileira, sugerindo que essas devam ser investigadas antes de intervenções cirúrgicas. / The knowledge of the location, as well as the configuration of the anatomical structures and their respective variations are extremely important for the planning of surgical procedures involving this bone. The aim of this study was evaluate the mandibular anatomy and its variations through Cone Beam Computed Tomography (CBCT) in a Brazilian population. A total of 1254 CBCT scans were performed on the I-Cat Next Generation (Imaging Sciences International®) equipment under a protocol with 0.2 mm voxel, wide FOV (16cm x 13cm) and 40 seconds scanning time. Three trained and calibrated examiners evaluated the exams using I-Cat Vision software (Imaging Sciences International®). The data that were collected in Access form (Microsoft® Office) and analyzed for prevalence. In line, were correlated with gender. The prevalence results were: mental foramen located between the 1st and 2nd lower premolars (91.38%), anterior loop (12.57%), accessory canals (40%), bifid mandibular canal (BMC) (22%) and corticalized mandibular canal (33.84%). The mandibular canal, in all its extension, is located more for vestibular in the women, with statistically significant difference between genders (P = 0,002). There is no difference in V-L distance between genders in submandibular fovea area. The BMCs do not have a gender preference (P = 0.186). However, there is a statistically significant difference between the types (P = 0.001), and Retromolar is the most frequent. The use of CBCT scans allowed the identification of important mandibular anatomical features in a Brazilian population, suggesting that these should be investigated before surgical interventions.
86

Avaliação da raiz mesiovestibular de primeiros molares superiores para detecção do canal mesiopalatino com o uso da tomografia computadorizada de feixe cônico

Fontana, Mathias Pante January 2017 (has links)
Os molares superiores são um dos grupos dentários que mais recebem tratamentos endodônticos e apresentam grande complexidade anatômica nos seus sistemas de canais radiculares. A presença de um canal mesiopalatino (MP) na raiz mesiovestibular é um achado bastante comum e a sua não detecção está relacionada com um alto índice de insucessos na terapia endodôntica. Recentemente, a tomografia computadorizada de feixe cônico (TCFC) vem ganhando destaque na avaliação do canal MP pela sua capacidade de fornecer informações detalhadas e em três dimensões, sendo considerada o melhor método de imagem para essa investigação in vivo. Desta forma, o objetivo desta tese foi pesquisar a prevalência e simetria do número de canais da raiz mesiovestibular em primeiros molares superiores homólogos, por meio da TCFC, assim como, analisar o uso dos filtros de refinamento de imagem para esta investigação. Para o primeiro objetivo, desenvolveu-se uma pesquisa com 264 pacientes possuindo o primeiro molar superior bilateralmente. Foi encontrada simetria em 78,79% dos pacientes, sendo que o canal MP esteve presente bilateralmente em 67,42%. Do total de 528 dentes avaliados, 78% apresentaram o canal MP não havendo correlação da sua presença com sexo e faixa etária (p > 0,05). Para o segundo objetivo, 30 exames de TCFC foram avaliados com cinco diferentes filtros (Original, Smooth, Sharpen, Sharpen Mild, Angio Sharpen Low e Angio Sharpen High) além das imagens originais (sem filtro). Todos os filtros apresentaram altos índices de acurácia (> 83,3%), sensibilidade (> 90%) e especificidade (> 62%), sem diferença estatística (p > 0,05). Entretanto, quando o nível de certeza foi avaliado, os filtros Angio Sharpen High e Sharpen apresentaram os piores resultados, com diferença significativa para as imagens Originais (p <0,05). Os resultados das pesquisas conduzidas permitem concluir que o canal MP é uma condição altamente prevalente e a sua simetria bilateral é frequente. O emprego de filtros de imagem da TCFC não influenciou a detecção do canal MP, entretanto os filtros de maior realce devem ser evitados pois reduzem a certeza do diagnóstico. / The upper molars are the dental group that most receives endodontic treatments and presents great anatomical complexity of their root canal systems. The presence of a second mesiobuccal canal (MB2) is a common finding and its non-detection is related to a high failure rate in endodontic therapy. Recently, cone-beam computed tomography (CBCT) has been highlighted in the MB2 evaluation for its ability to provide detailed and three-dimensional information, and is considered the best imaging method for such investigation in vivo. Thus, the aim of this thesis was to investigate the prevalence and symmetry of the root canal numbers from the mesiobuccal root of first homologous upper molars, as well as to evaluate the use of CBCT image filters for that purpose. For the first objective, a research was developed with 264 patients having the first upper molar bilaterally. Symmetry was found in 78.79% patients, and the MB2 was bilaterally present in 67.42%. Out the total of 528 teeth evaluated, 78% presented the MB2, with no correlation with sex and age group (p > 0.05). For the second objective, 30 CBCT scans were evaluated with five different filters (Original, Smooth, Sharpen, Sharpen Mild, Angio Sharpen Low and Angio Sharpen High) in addition to the original images (none filter). All filters presented high levels of accuracy (> 83.3%), sensitivity (> 90%) and specificity (> 62%), with no statistical difference (p > 0.05). However, when the level of certainty was evaluated, Angio Sharpen High and Sharpen filters presented the worst results, with significant difference for Original images (p < 0.05). The results of the conducted studies allow us to conclude that the MB2 is a highly prevalent condition and its bilateral simmetry is frequent. The use of CBCT image filters did not influence the MB2 detection, however higher enhancement filters should be avoided because they reduce the certainty of the diagnosis.
87

Planejamento do tamanho do implante dentário utilizando imagens de radiografia panorâmica digital e tomografia computadorizada de feixe cônico

Correa, Leticia Ruhland January 2012 (has links)
O objetivo deste estudo foi comparar o tamanho do implante dentário (largura e comprimento) planejado utilizando-se radiografias panorâmicas digitais (D-pan), reconstruções panorâmicas geradas a partir de Tomografia Computadorizada de Feixe Cônico (TCFC-pan), e imagens transversais de Tomografia Computadorizada de Feixe Cônico (TCFC-transversais), em quatro sistemas de implantes. Para tal, foram avaliados 103 sítios de implantes unitários nas regiões de pré-molares superiores e molares inferiores em 71 pacientes. Em cada paciente foram realizadas uma radiografia panorâmica digital (D-pan) e uma Tomografia Computadorizada de Feixe Cônico (TCFC). Para a realização da D-pan, foi colocada uma esfera de metal de 5 mm de diâmetro na região edêntula para que fosse realizada a calibração linear da imagem. Os dados adquiridos nas TCFC foram reconstruídos em imagens panorâmicas de 10 mm de espessura (TCFC-pan) e em imagens transversais de 1 mm de espessura (TCFC-transversais). Foram realizadas medidas em todas as imagens. Todas as modalidades de imagem foram exibidas no mesmo monitor e avaliadas por três observadores que utilizando o programa PorDios, identificaram quatro pontos de referência no espaço disponível e delimitaram o sítio de implante. Os tamanhos (largura e comprimento) dos implantes foram comparados entre as três modalidades de imagem e as diferenças foram analisadas. Utilizando o software SPSS, foi selecionado o tamanho do implante mais próximo (igual ou menor) que serviria no espaço disponível, baseado nos tamanhos existentes nos quatro sistemas utilizados (Nobel Biocare, Straumann, 3i e Neodent). O tamanho do implante selecionado nas imagens TCFC transversais foi comparado com o tamanho do implante selecionado nas outras duas modalidades (D-pan e TCFC-pan), para cada um dos sistemas separadamente. Como resultado, na maioria das vezes, o tamanho do implante foi menor nas TCFC-transversais, do que quando comparado com D-pan e TCFC-pan. Houve diferença significativa na largura do implante nas regiões de pré-molares entre D-pan e TCFC-pan. O implante foi significantemente mais curto na TCFC-transversal do que na D-pan, nas regiões de molares. A maioria das mudanças ocorreu para um tamanho mais fino e mais curto, que resultou em um tamanho de implante significantemente menor nas TCFC-transversais. Os resultados permitem concluir que quando o implante é planejado utilizandose imagens transversais de TCFC este é selecionado em um tamanho mais fino e mais curto do que quando idealizados em radiografias panorâmicas digitais. / The objective of this study was to compare the implant size (width and length) planned with digital panoramic radiographs, CBCT-generated panoramic views, or CBCT cross-sectional images, in four implant systems. Seventy-one patients with a total of 103 single-unit implants in the upper premolar and/or lower molar regions were examined with digital panoramic radiography (D-PAN) and cone beam computed tomography (CBCT). A 5-mm in diameter metal ball was placed in the edentulous area for the D-PAN. CBCT data sets were reformatted to a 10-mm thick CBCT panoramic view (CBCT-pan) and 1-mm cross-sections (CBCT-cross). Measurements were performed in the images using dedicated software. All images were displayed on a monitor and assessed by three observers who outlined a dental implant by placing four reference points in the site of the implant-to-be. Differences in width and length of the implant-to-be from the three modalities were analyzed. An automated program selected the implant size, which was the closest (smaller or equal) size implant that would fit the measured size, based on the sizes available in four worldwide-used implant systems (Nobel Biocare, Straumann, 3i and Neodent). The implant size selected in the CBCT-cross images was then compared to that selected in the other two modalities (D-PAN and CBCT-pan) for each of the implant systems separately. The implant-to-be (average measurements among observers) was narrower when measured in CBCT-cross compared with both D-PAN and CBCT-Pan. For premolar sites, width also differed significantly between D-PAN and CBCT-pan modalities. The implant-to-be was also significantly shorter when recorded in CBCT-cross than in D-PAN. In premolar sites there were no significant differences in implant length among the three image modalities. It mattered very little for the change in implant step sizes whether CBCT-cross was compared to D-PAN or CBCT-pan images. Our results show that the selected implant size differs when planned on panoramic or cross-section CBCT images. In most cases implant size measured in crosssection images was narrower and shorter than implant size measured in a panoramic image or CBCT-based panoramic view.
88

Capacidade diagnóstica da radiografia convencional e da tomografia computadorizada de feixe cônico para a detecção do canal mésio-palatino em molares superiores

Vizzotto, Mariana Boessio January 2011 (has links)
As dificuldades impostas pela anatomia do sistema de canais radiculares são causas freqüentes de falhas no tratamento endodôntico, principalmente no primeiro molar superior onde a prevalência do canal mésio-palatino (MP) é variável. A condição clínica do dente e a presença de materiais restauradores ou obturadores parecem impor dificuldades para a detecção da presença do canal MP, especialmente quando métodos de imagem são utilizados. Assim, este estudo teve como objetivos: i) avaliar a capacidade diagnóstica da radiografia convencional e da tomografia computadorizada de feixe cônico (TCFC) com diferentes tamanhos de voxel na detecção do canal MP em diferentes situações radiculares; e, ii) avaliar a reprodutibilidade do diagnóstico do canal MP nas mesmas condições. Exames radiográficos e tomográficos (voxel 0.2-mm, 0.25-mm e 0.3-mm), de oitenta e nove molares superiores humanos extraídos foram realizados em três etapas: canal mésio-vestibular (MV) vazio, obturado e após a desobturação. Em seguida, foi realizada a infiltração de corante e diafanização dos dentes. Para a análise estatística utilizou-se o software PASW Statistics 17.0. Para o primeiro objetivo, um examinador, cegado e calibrado, avaliou as imagens para a detecção do canal MP. Como resultados desse estudo pôde-se observar que a TCFC é um método complementar fidedigno para a investigação do canal MP. Em dentes com o canal MV obturado deve-se escolher o protocolo 0.2-mm, entretanto para canais radiculares sem preparo e sem obturação e canais desobturados, a escolha do tamanho de voxel 0.3-mm mostrou-se suficiente para um correto diagnóstico. Para o segundo objetivo proposto, três examinadores, calibrados e cegados, avaliaram as imagens e diagnosticaram a presença ou ausência do canal MP. Na avaliação de reprodutibilidade de diagnóstico, pode-se concluir que a condição do canal foi o fator mais relevante para a variação nos resultados quando comparado ao tamanho do voxel e experiência do examinador. Esses resultados devem ser considerados quando existe a suspeita da presença de um canal MP em um dente onde o re-tratamento endodôntico for necessário, visto que a remoção do material antes da solicitação do exame por imagem reduz os artefatos permitindo a utilização de um protocolo com voxel 0.3-mm, que se mostrou capaz de permitir um correto diagnóstico com menor dose de exposição para o paciente. / The difficulties imposed by the anatomy of the root canal system are a frequent cause of endodontic treatment failures, especially in upper first molars where the prevalence of the second mesiobuccal canal (MB2) is variable. Several methods have been proposed to detect this root canal, but also is important to consider the influence of the clinical condition of the over tooth its the correct diagnosis. Therefore, this study was aimed: i) to assess the diagnostic ability of conventional radiography and CBCT with different voxel sizes in the detection of MB2 in different root conditions; and, ii) to assess the reproducibility of this diagnosis under the same conditions. Radiographs and CBCT scans (0.2-mm, 0.25-mm and 0.3-mm voxel) of eighty-nine extracted human molars were performed in three steps: first mesiobuccal canal (MB1) non filled, filled and after deobturation. Then, samples were cleared. Three examiners, calibrated and blinded, evaluated the images and pointed out the presence or absence of MB2. Statistical analysis was crried on with the PASW Statistics 17.0 software. It was observed that CBCT is a secure complementary method for investigating the presence of MB2. Moreover, when the MB1 canal is filled should be choose the 0.2-mm protocol. The 0.3-mm voxel size images proved to be adequate for a correct diagnosis when the MB1 was non filled or deobturated. In the assessment of diagnostic reproducibility, it can was concluded that the MB1 seemed to be a determinant factor for the result outcome canal condition when compared to the voxel size and the examiner’s experience. These results should be considered when an endodontic re-treatment was indicated, specially when the presence of a MB2 is suspected. The removal of endodontic material prior to request the images exams reduces the presence of artifacts, allowing the use of the 0.3-mm voxel protocol. It was able to allow a correct diagnosis with less patient exposure to the X ray.
89

Avaliação da interface osso e implantes dentários em exames por imagem e suas implicações no diagnóstico

Vidor, Michele Machado January 2015 (has links)
Introdução: O desenvolvimento da radiologia digital e da tomografia computadorizada de feixe cônico (TCFC) permitiu aos profissionais diferentes formas de avaliação das imagens. Entretanto, frente a materiais metálicos, é observada a formação de artefatos tanto na imagem tomográfica, quanto nas radiografias digitais após a aplicação de filtros de processamento. Objetivo: Esta pesquisa objetivou investigar a interferência provocada por materiais metálicos na avaliação da interface osso/implante em radiografias periapicais convencional e digital, e em TCFC. Materiais e Métodos: Foram inseridos implantes de titânio em 74 blocos de costelas bovina frescas. Em 37, a inserção foi em íntima relação com as paredes ósseas (Grupo Controle-GC) e nos outros 37 com um espaço de 0.125 mm (Grupo Teste-GT). As radiografias periapicais foram realizadas com filme convencional e dois sistemas digitais de placa de fósforo. As imagens volumétricas foram adquiridas em dois equipamentos de TCFC. Nos sistemas digitais as imagens foram investigadas com e sem a utilização dos filtros e, nas tomografias, com diferentes protocolos de aquisição. Três examinadores treinados e cegados realizaram a avaliação utilizando uma escala Likert de cinco pontos. Foram utilizados testes de sensibilidade, especificidade e acurácia (área sob a curva ROC) e teste de concordância de Kendall (W). Resultados: Na avaliação radiográfica (ARTIGO I), foi observada maior acurácia do exame convencional e das imagens do sistema VistaScan com filtros Caries2 e Endo e do sistema Express com filtro Sharpen3 na detecção da justaposição entre osso e implante. Na avaliação tomográfica (ARTIGO II), somente as imagens do tomógrafo i-Cat com a resolução de voxel de 0.125mm não apresentaram diferença significativa com a radiografia convencional na acurácia diagnóstica. Conclusão: Na avaliação radiográfica da justaposição entre o osso e o implante, preferência deve ser dada às radiografias convencionais ou às digitais com filtros de realce (Caries2, Endo e Sharpen3). Em caso da existência de exames de TCFC com voxel 0.125 mm, tal avaliação também pode ser realizada. / Introduction: The development of digital radiology and computed tomography cone beam (CBCT) enabled professionals different possibilities of images evaluation. However, when metallic materials are present, artifacts formation can be observed in tomographic images and in digital radiography after processing fiters. Objective: This study investigated the interference caused by metallic materials in bone/implant interface evaluation with conventional and digital periapical radiographs, and CBCT. Materials and Methods: Titanium implants were placed into 74 fresh bovine ribs. In 37, the implants were in close relation with the bone walls (Control Group-CG) and the remaining 37 ribs preparations promoted a 0.125 mm space (Test Group-GT) .The periapical radiographs were taken with conventional film and digital photostimulable phosphor plate (PSP) system of two commercial brands. The volumetric images were acquired in two CBCT equipment. The digital images were investigated with and without the use of processing filters available and the tomographic with different acquisition protocol. Three trained and blinded examiners performed the evaluation using a five points Likert scale. Sensitivity, specificity and accuracy (area under the ROC curve) tests were used and Kendall´s coefficient of concordance (W). Results: In the radiographic evaluation (Article I), there was a higher accuracy to detect the juxtaposition between bone and implant with the conventional radiography and the images of VistaScan system using the Caries2 and Endo filters, and Express system with Sharpen3 filter. In the tomographic evaluation (Article II), only the images with 0.125mm of voxel resolution from i-Cat CBCT showed no significant difference with conventional radiography in the diagnostic accuracy. Conclusion: In radiographic evaluation of juxtaposition between bone and implant preference should be given to conventional radiographs or in digital radiographs to Caries2, Endo and Sharpen3 enhancement filters. In case of the existence of CBCT exams (voxel 0.125mm), such evaluation can also be performed.
90

Efeitos dento-esquelÃticos da expansÃo rÃpida de maxila assistida cirurgicamente com e sem disjunÃÃo pterigomaxilar: um ensaio clÃnico randomizado duplo-cego. / Dental and skeletal effects of surgically assisted rapid palatal expansion with and without pterygomaxillary disjunction: a double-blind, randomized clinical trial

Marcelo Ferraro Bezerra 23 January 2014 (has links)
DiscrepÃncia transversal dos arcos dentÃrios à um problema comum em pacientes que necessitam de tratamento ortodÃntico. O tratamento de escolha para pacientes adultos com deficiÃncia maxilar transversa à mediante a tÃcnica de expansÃo rÃpida de maxila assistida cirurgicamente (ERMAC). Ainda nÃo hà consenso sobre o melhor protocolo cirÃrgico, bem como quais alteraÃÃes dento-esquelÃticos ocorrem apÃs ERMAC. Nesse contexto, a presente tese, constituÃda por um artigo, tem por objetivo: avaliar e comparar, atravÃs de tomografias computadorizadas de feixe cÃnico, os efeitos esquelÃticos e dentÃrios produzidos por duas tÃcnicas de ERMAC, com (+DP) e sem (&#8722;DP) disjunÃÃo pterigomaxilar. Realizou-se um ensaio clÃnico randomizado duplo-cego, com pacientes submetidos a ERMAC e divididos em dois grupos de acordo com a tÃcnica cirÃrgica. Tomografias computadorizadas foram feitas antes da cirurgia, apÃs 01 mÃs e no final do perÃodo de contenÃÃo. Vinte e quatro pacientes elegÃveis foram alocados randomicamente e distribuÃdos em dois grupos. ExpansÃo Ãssea maxilar, palatina e alveolar bem como expansÃo e inclinaÃÃes dentÃrias ao nÃvel dos dentes molares e caninos foram avaliadas nos 03 perÃodos. Ambas as tÃcnicas promoveram expansÃo dento-alveolar transversal significativa nas regiÃes dos molares e caninos, sem diferenÃa estatÃstica entre os dois grupos. O grupo ERMAC +DP mostrou maior expansÃo Ãssea palatina posterior e menor inclinaÃÃo dos molares do que o grupo ERMAC &#8722;DP. O grupo ERMAC &#8722;DP proporcionou mais expansÃo dentÃria na Ãrea de molares. Na regiÃo anterior, o grupo ERMAC &#8722;DP mostrou uma maior expansÃo alvÃolo-palatina. Em conclusÃo, a ERMAC com ou sem DP sÃo mÃtodos confiÃveis de se obter expansÃo maxilar, embora apresentem pequenas diferenÃas nos padrÃes de alteraÃÃes esquelÃticas e dentÃrias. A DP parece facilitar um maior grau de expansÃo Ãssea posterior, enquanto a nÃo realizaÃÃo da disjunÃÃo pode favorecer uma maior expansÃo dentÃria. Hà uma correlaÃÃo positiva entre a DP e o grau de abertura do aparelho expansor com uma maior expansÃo alvÃolo-palatina posterior, enquanto a nÃo disjunÃÃo correlaciona-se com uma maior expansÃo dentÃria e alvÃolo-palatina anterior. / Transversal discrepancy of dental arches is a common problem founded among patients who need orthodontic treatment. The treatment of choice for transverse maxillary deficiency in adult patients is the surgically assisted rapid maxillary expansion (SARME). There is not a consensus yet on which is the best surgical protocol and what dento-skeletal changes occur after SARME. In this context, the aim of this thesis is to evaluate and compare, using cone beam computed tomography, skeletal and dental changes produced by two SARME techniques, with (+PD) and without (&#8722;PD) pterygomaxillary disjunction. This study was designed as a randomized, double-blind clinical trial. Patients were divided between two groups according to SARME technique. Computerized tomography scans were performed before surgery, after one month and at the end of the stabilization period. Twenty-four eligible patients were equally distributed in both groups. Maxillary, palatal and alveolar bone expansion, as well as tooth expansion and tipping at the molars and canines areas, were evaluated in 03 follow-up periods. Both techniques demonstrated a significant transversal dentoalveolar expansion at the molars and canines areas, with no statistical difference between the groups. The SARME +PD group showed greater posterior palatal bone expansion and lesser molar tipping. The SARME &#8722;PD group provided more dental expansion in the molar area. In the anterior region, the SARME &#8722;PD group showed greater palatine and alveolar expansion. In conclusion, SARME with or without PD are reliable techniques for maxillary expansion, although these techniques present slight differences at the patterns of skeletal and dental changes. The PD seems to facilitate a greater degree of posterior bone expansion, while its absence favors greater dental expansion. There is a positive correlation between the PD and the opening of the palatal expander device with a greater posterior alveolar and palatal expansion, while the non-disjunction correlates with greater anterior dental, alveolar and palatine expansion.

Page generated in 0.116 seconds