• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 15
  • 15
  • 11
  • 10
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Soluções analíticas para convecção forçada laminar em tubos circulares externamente aletados

Carlos Antonio Cabral dos Santos 01 April 1990 (has links)
A técnica de transformada integral generalizada é extendida para se obter soluções analíticas em problemas lineares de difusão com coeficientes variáveis nas comdições de contorno e aplicada ao estudo da convecção forçada laminar em tubos circulares externamente aletados, nos regimes permanentes e periódicos. Analisa-se o problema da região de entrada térmica em regime permanente com condição de entrada uniforme, usando variações tipo degrau e harmônica no coeficiente de transferência de calor externo, para simular a presença das aletas radiais. São obtidos resultados numéricos para as grandezas térmicas de interesse, como temperatura média global, as taxas de transferência de calor adimensional e número de Nusselt global. Compara-se, também, resultados para as taxas de transferência de calor adimensional com as disponíveis na literatura, analisando-se, criticamente, os efeitos das variações de espaçamento e espessura das aletas na troca térmica com o fluido. Estuda-se o problema da região de entrada téwrmica em regime periódico para um tubo aletado externamente e sujeito a variações com o tempo na temperatura de entrada no canal. Investiga-se, então, a influência da frequência das oscilações na resposta térmica do sistema, em termos das distribuições de amplitudes e ângulos de fase ao longo do tubo, para as grandezas de interesse como temperatura média global e fluxo de calor na parede. Finalmente, analisa-se os efeitos de diferentes combinações espaçamento-espessura do arranjo de aletas, na propagação das oscilações na entrada, ao longo do canal.
2

Escoamento laminar e transferência de calor em fluidos imisciveis sem estratificação

Élcio Nogueira 01 March 1988 (has links)
Trata-se da solução analítica, pela técnica de transformada integral finita, do problema de convecção forçada em regime laminar de fluidas Newtonianos imiscíveis, não estratificados, em dutos de geometria simples, tais como tubos e canais de placas planas paralelas. Efetua-se uma extensão do método de contagem de sinal (Sign-Count), para a solução do problema de Sturm-Liouville unidimensional associado a múltiplas regiões, considerando-se descontinuidades nas interfaces. Determina-se os perfis de velocidades e obtém-se expressões e resultados para fatores de atrito, potências de bombeamento e vazões para diversas condições de operação. Estuda-se a influência de espessura da camada do fluido próximo à parede nos coeficientes de transferência de calor em dois sistemas distintos a saber: sistema água-óleo, com aplicação no bombeamento de fluidos muito viscosos, e sistema querosene-água, com aplicação na proteção contra incrustações e corrosão em trocadores de calor. Obtém-se resultados gráficos e númericos para temperaturas médias, números de Nusselt e calor total transferido. Procura-se, portanto, estabelecer a influência da espessura do fluido mais externo no perfil de temperatura em desenvolvimento, e em grandezas relacionadas, em duas situações bastante distintas: na primeira o fluido de menor ciscosidade e de maior condutividade encontra-se em contato com a parede do duto; na segunda, o fluido que entra em contato tem menor condutividade e maior viscosidade.
3

Simulação numérica da convecção forçada turbulenta acoplada à condução de calor em dutos retangulares.

Gustavo Adolfo Ronceros Rivas 13 December 2010 (has links)
No presente trabalho, uma simulação numérica foi adotada para resolver o problema da convecção forçada turbulenta acoplada à condução de calor em um duto de seções transversais quadradas e retangulares. As equações utilizadas para a convecção turbulenta são as equações da conservação de massa, quantidade de movimento e energia (equações médias de Navier Stokes, RANS). Estas equações são acopladas à equação da condução de calor aplicada a quatro placas situadas ao redor do canal. Estas placas são acopladas entre si sem resistência térmica. Assunções foram feitas principalmente no escoamento, tais como condição do escoamento turbulento completamente desenvolvido, incompressível e propriedades constantes. A título de comparação, dois modelos de turbulência foram utilizados para resolver as equações da quantidade de movimento e outros dois modelos para resolver a equação da energia. Isto é, para determinar o campo de velocidade, os modelos de turbulência, k-? não linear (NLEVM) e tensão de Reynolds (RSM) (este último simulado em um código comercial) foram adotados e estudados. O campo de temperatura foi determinado a partir de outros dois modelos: Simple Eddy Diffusivity (SED), baseado na hipótese de Prandtl turbulento constante; e Generalized Gradient Diffusion Hypothesis (GGDH). Neste último, como a transferência de calor turbulenta depende das tensões cisalhantes, a anisotropia foi considerada. Cabe ressaltar que estes dois últimos modelos da equação de energia para o fluido, assim como a equação da condução de calor com incorporação da geração de calor para a parte sólida foram adimensionadas e desenvolvidas no código de programação FORTRAN. Os modelos foram validados baseados nos resultados experimentais e numéricos da literatura. Finalmente, os resultados desta investigação permitem avaliar o campo de temperatura do fluido para diferentes seções da seção transversal ao longo da direção principal do escoamento, o qual é influenciado principalmente pela distribuição da temperatura na parede.
4

Resfriamento conjugado de aquecedores discretos em canais / Conjugate cooling of discrete heaters in channels

Alves, Thiago Antonini 07 July 2010 (has links)
Orientador: Carlos Alberto Carrasco Altemani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T09:22:29Z (GMT). No. of bitstreams: 1 Alves_ThiagoAntonini_D.pdf: 12931422 bytes, checksum: b3858d05581229381f7d14684d29e979 (MD5) Previous issue date: 2010 / Resumo: A transferência de calor conjugada por convecção forçada e condução de três aquecedores 2D montados rentes ou protuberantes na placa inferior (substrato) de um canal de placas paralelas foi investigada numericamente em regime permanente. Uma taxa uniforme de geração de calor foi assumida em cada aquecedor e seu resfriamento ocorreu por meio de um escoamento forçado de ar com propriedades constantes em regime laminar. Na entrada do canal, os perfis de velocidade e de temperatura do escoamento eram uniformes. Este problema está relacionado ao resfriamento de componentes eletrônicos montados numa placa de circuito impresso. Para um substrato adiabático, o resfriamento dos aquecedores ocorre apenas por convecção forçada. Para um substrato condutivo, dois mecanismos para a transferência de calor dos aquecedores para o escoamento fluido foram considerados. Um, por convecção forçada, diretamente das superfícies dos aquecedores em contato com o escoamento e outro, por condução através das interfaces substrato-aquecedor. As equações de conservação foram resolvidas dentro de um domínio único, que englobou as regiões sólidas e de fluido, através de um procedimento acoplado. Nesta Tese foi proposto um descritor invariante do processo conjugado de transferência de calor por convecção forçada e condução, por meio de coeficientes de influência conjugados g+, agrupados numa matriz quadrada G+. Com este descritor, a temperatura de cada aquecedor foi determinada a partir de taxas arbitrárias de geração de calor nos aquecedores. Os resultados foram obtidos para números de Reynolds na faixa de 600 a 1900, correspondendo a velocidades médias de entrada do ar no canal na faixa de 0,5 m/s a 1,5 m/s. Os efeitos da razão entre a condutividade térmica do substrato e a do ar foram estudados na faixa de 0 (substrato adiabático) a 80, uma faixa típica de materiais de circuito impresso. A altura dos aquecedores variou entre 0 (aquecedores rentes) e 35% em relação à altura do canal, sendo que em todos os casos o aquecedor possuía uma condutividade térmica 500 vezes maior do que a do ar. / Abstract: The conjugate heat transfer by forced convection and conduction from three 2D heaters either flush mounted or protruding from the lower plate (substrate) of a parallel plates channel was investigated numerically under steady state conditions. A uniform heat generation rate was assumed in each heater and the cooling was performed by means of a forced air flow with constant properties in the laminar regime. At the channel entrance the flow velocity and temperature profiles were assumed uniform. This problem is related to the cooling of electronic components mounted on a circuit board. For an adiabatic substrate, the heaters are cooled only by forced convection. For a conductive substrate, two mechanisms were considered for the heat transfer from the heaters to the fluid flow. One, by forced convection, directly from the heaters surfaces in contact with the flow, and the other, by conduction through the heaters-substrate interfaces. The conservation equations were solved through a coupled procedure within a single calculation domain comprising the solid and fluid regions. In this Thesis an invariant descriptor of the conjugate forced convection and conduction heat transfer was proposed by means of conjugate influence coefficients g+ which were grouped in a square matrix G+. With this descriptor, the temperature of each heater was obtained from an arbitrary distribution of the heat generation rate in the heaters. The results were obtained for Reynolds numbers Re in the range from 600 to 1900, corresponding to average air velocities in the channel entrance from 0.5 m/s to 1.5 m/s. The ratio of the substrate plate thermal conductivity relative to that of the air was considered in the range from 0 (adiabatic substrate) to 80, typical of printed circuit boards. The heaters' height in the channel ranged from 0 (flush mounted) to 35 % of the channel height, while their thermal conductivity was always assumed equal to 500 that of the air. / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
5

Termofluidodinamica de sucos de frutas pseudoplasticos em dutos cilindricos e anulos concentricos / Thermo-fluid dynamics to pseudoplastic fruit juices in cilindrical ducts and concentric annuli

Gratão, Ana Carolina Amaral 17 April 2006 (has links)
Orientadores: Vivaldo Silveira Junior, Javier Telis Romero / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-06T15:00:42Z (GMT). No. of bitstreams: 1 Gratao_AnaCarolinaAmaral_D.pdf: 2034155 bytes, checksum: 7a7cc4a961cab6b38ae3dc5ee5f3f9d8 (MD5) Previous issue date: 2006 / Doutorado / Engenharia de Alimentos / Doutor em Engenharia de Alimentos
6

Avaliação do processo de congelamento em tunel portatil com convecção forçada por exaustão e insuflação / Freezing process evaluation using a portable forced air tunnel with air evacuation and air blowing in pallets

Barbin, Douglas Fernandes, 1980- 24 August 2007 (has links)
Orientador: Vivaldo Silveira Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-08T21:24:52Z (GMT). No. of bitstreams: 1 Barbin_DouglasFernandes_M.pdf: 2471115 bytes, checksum: d96f699c328a8086ec9a94c3315aab07 (MD5) Previous issue date: 2007 / Resumo: A redução do tempo de congelamento de produtos alimentícios é um objetivo almejado, devido este processo ser caro e que envolve elevado gasto energético. Os produtos alimentícios são predominantemente congelados em túneis com convecção forçada por insuflação de ar; porém, é preferível realizar a exaustão de ar, ao invés de insuflação, pelo fato da exaustão promover uma circulação de ar mais uniforme ao redor do produto. Um túnel de ar forçado por exaustão é composto por um ventilador que circula de forma a retirar o ar, produzindo uma região de baixa pressão, onde se localiza o produto, buscando uniformizar a circulação do ar frio em contato com o mesmo. Desse modo, este trabalho se propôs à montagem experimental de um túnel ¿portátil¿ de congelamento por ar forçado, onde se pode estudar a utilização de insuflação e exaustão de ar. Este túnel foi construído e alocado no interior de uma câmara de armazenagem de produtos congelados, buscando melhorar a distribuição do ar, potencializando a troca térmica entre o ar e o produto a ser congelado. A montagem foi monitorada através de termopares para determinação das curvas de congelamento e eficiência do sistema. Durante o processo de congelamento, foi avaliada a transferência de calor através da montagem, comparando os processos de exaustão e insuflação e analisados os coeficientes de transferência de calor entre o ar de resfriamento e o produto em diferentes posições e camadas do palete, bem como a distribuição do ar de resfriamento em circulação ao redor do produto. Os resultados mostraram uma redução no tempo de congelamento das amostras com a utilização do túnel ¿portátil¿ em relação ao processo sem a utilização deste aparato dentro da câmara. O processo de exaustão apresentou uma redução de até quatro horas para o congelamento em relação à insuflação. Os valores de coeficiente de convecção foram maiores para a exaustão do que para a insuflação em todas as camadas da montagem, com exceção da superior, que recebia o ar diretamente do interior da câmara na insuflação. Um coeficiente de heterogeneidade foi proposto para avaliar a diferença de temperaturas no produto durante o congelamento. Estes valores, juntamente com a análise das temperaturas obtidas no processo, mostraram que a distribuição do ar, bem como a transferência de calor, ocorre de maneira mais homogênea no interior do palete na exaustão do que na insuflação / Abstract: The conditions necessary to keep the air temperature and movement at the product surface will determine the freezing process efficiency. Since the energy level could implement on the final cost, the reduction of the freezing process time was a major goal in the whole experiment. Food products are predominantly frozen in air blast freezing tunnels. Therefore, exhausting air is preferable than blowing it through, since it minimizes air short-circuiting and results in more uniform cooling. To produce an homogeneous refrigeration, the main configuration to be determined for pallets storing plastic packages in boxes are the package distribution and air orientation. The main components of an exhausting forced-air tunnel are a fan that causes the equipment inside air evacuation creating a low pressure region. The product is arranged on this spot creating uniform distribution of the cold air inside the equipment, around the product. Therefore, the objective of this work is to build an experimental portable forced-air freezing tunnel, and work on comparative studies with air exhausting and blowing. The tunnel was built and placed inside a freezing product storage chamber, and the objective was to improve the air circulation and the thermal distribution between the product and cold air, for a sample batch left inside the chamber. The batch was monitored using thermocouples for freezing variation and system efficiency graphic determination. It was also provided the heat transfer analysis, comparing the exhausting and blowing process, and the heat transfer coefficients of the cold air and the product as well as the air distribution around the product. The results have shown reduction of the freezing time of the samples when the portable tunnel was used comparing without the tunnel tests (reference). The air evacuation process reduced up to four hours with comparison to the blowing system the freezing process. Convective coefficient results were higher for air evacuation than air blowing in every part of the batch, except for the upper layer of products were the cold air of the chamber was directly in contact with the product. These results, with the temperature analysis obtained, indicated that the air distribution occurs more uniformly around the products in the exhausting process than blowing system, as well as the heat transfer / Mestrado / Mestre em Engenharia de Alimentos
7

Resfriamento conjugado de aquecedores protuberantes em um duto retangular / Conjugate cooling of protruding heaters in a rectangular duct

Loiola, Bruna Rafaella, 1987- 12 May 2013 (has links)
Orientador: Carlos Alberto Carrasco Altemani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T09:07:23Z (GMT). No. of bitstreams: 1 Loiola_BrunaRafaella_M.pdf: 2801156 bytes, checksum: 0bbef2296c5a3a938f63b6246554ab2d (MD5) Previous issue date: 2013 / Resumo: A transferência de calor conjugada por convecção forçada-condução de dois aquecedores protuberantes montados na parede inferior (substrato) de um duto retangular foi investigada através de medidas experimentais em laboratório. Potência elétrica era dissipada em resistências embutidas nos aquecedores feitos de alumínio, que eram resfriados em regime permanente por um escoamento forçado de ar no duto. Cada aquecedor transferia calor por convecção diretamente das suas superfícies em contato com o escoamento e por condução para a placa do substrato através da interface comum. Esta condução de calor espalhava na placa do substrato e era transferida por convecção da placa para o escoamento de ar no duto. O resfriamento conjugado dos aquecedores na placa de substrato foi descrito por uma matriz de coeficientes conjugados obtidos por meio de testes experimentais realizados com um aquecedor ativo por vez, em uma faixa do número de Reynolds do escoamento entre 1600 e 6400. Foram utilizadas duas montagens experimentais praticamente idênticas, uma com a placa do substrato de acrílico e a outra, de alumínio. O número de Nusselt adiabático, que é um descritor invariante do processo convectivo de troca de calor, também foi avaliado nos testes com o substrato de acrílico. Os coeficientes conjugados obtidos nestes testes foram então utilizados para prever as temperaturas dos aquecedores em testes adicionais com os dois simultaneamente ativos, sob condições variadas de escoamento e aquecimento. A concordância dessas temperaturas indicou que esses coeficientes são descritores invariantes do resfriamento conjugado dos aquecedores discretos no duto. Simulações numéricas do escoamento e da transferência de calor no duto considerado foram efetuadas com o pacote computacional PHOENICS em um domínio tridimensional semelhante ao duto experimental. Os resultados numéricos obtidos foram comparados com as medidas experimentais / Abstract: Conjugate heat transfer by forced convection-conduction of two protruding heaters mounted on the lower wall (substrate) of a rectangular duct was investigated through experiments in laboratory. Electric power dissipation in the Aluminum heaters¿ embedded resistances was transferred under steady state conditions to forced airflow in the duct. Heat losses from each heater included direct convection from its surfaces in contact with the airflow and conduction to the substrate plate through their common interface. This heat conduction was spread in the substrate plate and eventually transferred by convection from the plate to the airflow in the duct. The heaters¿ conjugate cooling was described by a conjugate matrix with coefficients obtained from experimental tests with a single active heater at a time, in the range of the airflow Reynolds number from 1,600 to 6,400. Two almost identical assemblies were used, one with a Plexiglas plate and the other with Aluminum. The adiabatic Nusselt number, an invariant descriptor of the convective heat transfer, was also evaluated in the tests with the Plexiglas plate. The conjugate coefficients were used to predict the heaters¿ temperatures from additional tests with both active heaters, for arbitrary airflow rates and heaters¿ power dissipation. An agreement of these temperatures indicated that the conjugate coefficients are invariant descriptors of their conjugate cooling. Numerical CFD simulations were performed using the PHOENICS software in a three dimensional domain similar to the experimental assembly. The numerical results were compared to those of the experiments / Mestrado / Termica e Fluidos / Mestra em Engenharia Mecânica
8

Solução numérica de escoamentos termofluidodinâmicos bidimensionais laminares pelo método de Lattice-Boltzmann / Numerical solution of two-dimensional laminar thermofluidynamic flows using Lattice-Boltzmann Method

Mapelli, Vinícius Pessôa 22 February 2019 (has links)
O método de Lattice-Boltzmann (MLB) vem ganhando destaque nas últimas décadas pela sua capacidade de solução de escoamentos complexos como escoamentos multifásicos e multicomponentes, meios porosos e magnetohidrodinâmicos. Também existem extensões do método para a solução de problemas de advecção-difusão, que permitem acoplamento dessa metodologia para a solução numérica do conjunto de equação Navier-Stokes-Fourier. No trabalho presente, os objetivos iniciais podem ser resumidos no estudo dos conceitos básicos necessários para entender a derivação do método a partir da teoria cinética e estudo do método de Lattice Boltzmann, com operador de colisão mais simples conhecido como operador BGK, para problemas bidimensionais térmicos e fluidodinâmicos. A implementação numérica do método foi realizada em linguagem C, Matlab e CUDA C, com foco na solução de cinco problemas incompressíveis e laminares em regime permanente, conhecidos na literatura: equação viscosa de Burgers, escoamento de Poiseuille com transferência de calor, convecção natural em uma cavidade quadrada, regimes de convecção natural, forçada e mista em uma cavidade com uma das fronteiras móvel, e por fim, convecção forçada em uma cavidade ventilada, com uma entrada e uma saída. Além disso, um pequeno estudo no tempo computacional utilizando três implementações distintas foram testadas: implementação em série, uso de interpolações entre malhas grosseiras como condição inicial para malhas mais refinadas, e por fim, a adição da implementação do código em paralelo. Os ganhos de tempo entre a primeira e segunda estratégia ficaram entre 1.5 e 6, ao passo que o código paralelizado mostrou-se entre 20 e 25 vezes mais rápido que a segunda estratégia testada, comprovando o benefício de utilizar o processamento em paralelo em unidades gráficas. Os resultados obtidos para os problemas foram comparados com outros trabalhos da literatura, mostrando boa concordância para os primeiros quatro problemas estudados. Para a cavidade ventilada, diferenças relativas de até 15.7% no coeficiente de troca de calor e de até 28.38% para o coeficiente de queda de pressão adimensional foram observadas. Análises a respeito dos termos de erros do método apresentado, e a utilização de outras metodologias com método de Lattice Boltzmann, como por exemplo, o emprego de outros operadores de colisão, para trazerem mais estabilidade e precisão, podem elucidar melhor as divergências observados entre o trabalho presente e outros trabalhos da literatura. / Lattice-Boltzmann Method (LBM) has gained attention over last decades due to its performance in solving complex flows such as multiphase and multicomponent flow, porous media and magnetohydrodynamics. There are also further techniques which makes LBM able to solve advection-difussion problems, which allows coupling this methodology to solve Navier-Stokes-Fourier equations. In this work, initial goals are, in a few words, studying main concepts required to understand numerical method origins from kinectic thery, and studying the method implemetantion to solve 2D fluid dynamic and thermal problems. Numerical implemetation was written in C, CUDA C and Matlab languages, keeping in focus five different cases of laminar incompressible flows in steady state: viscous Burgers\' equation, thermal Poiseuille, natural convection in square cavities, natural, forced and mixed convection in a lid driven cavity, and, finally, forced convection in a ventilated cavity, with one inlet and outlet ports. Besides that, a quick study regarding impact in simulation time of three distinct approaches was conducted. First approach consists in implementing a serial code, the second in using interpolation for coarser grids results as initial condition for finer meshes, and the last one is adding parallelized code implementation. Time gains between first and second approach range from 1.5 to 6, while parallelized code was able to converge from 20 to 25 times faster than second approach, confirming great benefits in using graphics processing units. Results obtained from numerical solutions of problems were compared with other works from literature, and a good agreement among them was observed, specially in the first four problems studied. In ventilated cavity problem, relative differences up to 15.7% in heat transfer coefficient and up to 28.38% in dimensionless pressure drop coefficient were observed. A further error terms analysis of method used in this work, and use of distinct approaches, such as different collision operators, in order to increase numerical solution stability and accurarcy, may shed a light on results divergences observed between this work and others from literature.
9

Técnica de transformada integral generalizada no desenvolvimento simultâneo dos perfis de velocidade e temperatura em escoamento laminar em dutos de geometria simples

João Batista Campos Silva 01 May 1990 (has links)
A técnica de transformada integral generalizada é utilizada para a obtenção de soluções analíticas do problema de convecção forçada em regime laminar, na região de entrada de dutos de geometria simples, tais como canais de placas paralelas e dutos circulares. Nessa região as camadas limites hidrodinâmica e térmica estão se desenvolvendo simultaneamente. O fluido é considerado como newtoniano e suas propriedades físicas como constantes. São utilizadas distribuições de velocidades longitudinais na forma analítica, as quais estão disponíveis na literatura e foram obtidas por métodos de linearização da equação de qualidade de movimento na direção axial. A partir da distribuição de velocidade axial obtém-se a distribuição de velocidade normal e analisa-se a influência desta velocidade sobre os parâmetros de transferência de calor: temperatura média de mistura e números de Nusselt local e médio. Analisa-se também a influência de dois perfis de velocidades diferentes sobre os resultados. Obtém-se resultados numéricos para a temperatura média de mistura e números de Nusselt local e médio considerando-se a geometria de um canal de placas planas paralelas, resolvendo-se um sistema completo de equações diferenciais ordinárias acopladas, para vários números de Prandtl. Implementam-se também, soluções aproximadas para um cálculo mais rápido dos resultados, verificando-se a precisão de tais soluções. Quando possível os resultados são comparados com resultados existentes na literatura.
10

Análise da convecção forçada no escoamento bidimensional laminar em dutos circulares em variáveis primitivas via GITT. / Analysis of the forced convection in the bidimensional laminar flow in circular ducts in primitive variable by GITT.

Lopes, Mabel de Morais 28 September 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:45Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 1419023 bytes, checksum: 1bf50c9a366f8d01e4a2a3efdb0a5526 (MD5) Previous issue date: 2012-09-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this study the forced convection in the laminar flow in simultaneous developing is studied by applying the Generalized Integral Transform Technique to provide a hybrid analytical solution for the fields of velocity, pressure and temperature in circular ducts. The Continuity, Navier-Stokes, Poisson and Energy equations are formulated using primitive variables,knowing that the Poisson Equation was obtained from some mathematical manipulation made on the Navier-Stokes equations. The integral transformation is done in the Momentum equation in x, Poisson and energy equations, and the resulting equations are solved using the IMSL, DBVPFD subroutines and recovering the original potential for each profile studied. In this way it is possible to find a solution to the system by means of an expansion in terms of convenient eigenfunctions, to circular ducts, the eigenfunctions will be Bessel functions. In the following, some results from a practical point of view will be calculated and exhibited graphically such as: The Nusselt number, the f Re value, the study of the convergence profile of the velocity field, the mean velocity, the temperature, the mean temperature, pressure and the mean pressure in the middle of the duct will be analyzed. The results will be compared with the ones found in the literature to validate and adjust the model. / No presente trabalho a convecção forçada interna no escoamento laminar em desenvolvimento simultâneo é estudada aplicando a Técnica da Transformada Integral Generalizada para produzir um solução híbrida para os campos de velocidade, pressão e temperatura em dutos circulres. As equações da Continuidade, de Navier-Stokes, de Possion e da Energia são formuladas utilizando variáveis primitivas, sabendo-se que a equação de Poisson foi obtida a partir de algumas manipulações matemáticas feitas na equação de Navier-Stokes. A transformação integral é aplicada nas equações da quantidade de movimento na direção x, de Poisson e na equação da energia, e as equações resultantes são resolvidas com a subrotina numérica do IMSL, DBVPFD recuperando o potencial original para cada perfil em estudo. Assim é possível encontrar uma solução para o sistema de equações em termos de um expansão de autofunções, que para dutos circulares, as autofunções serão funções de Bessel. Em seguida resultados de interesse prático são calculados e exibidos graficamente como: número de Nusselt e f Re e estudos da convergência dos perfis de velocidade,velocidade média, temperatura, temperatura média, pressãoo e pressão média no centro do duto são analisados. Os resultados são comparados com os dados disponíveis na literatura para validação e ajustes do modelo.

Page generated in 0.0617 seconds