• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de imunossesor eletroquímico baseado no uso de polímero condutor e nanotubos de carbono para diagnóstico do infarto agudo do miocárdio

SILVA, Cybelle Emanuele da 24 February 2016 (has links)
Submitted by Alice Araujo (alice.caraujo@ufpe.br) on 2018-04-20T19:41:02Z No. of bitstreams: 1 DISSERTAÇÃO Cybelle Emanuele da Silva.pdf: 2250513 bytes, checksum: 4e34e57e4474ad3663b48e9669c360e2 (MD5) / Made available in DSpace on 2018-04-20T19:41:02Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO Cybelle Emanuele da Silva.pdf: 2250513 bytes, checksum: 4e34e57e4474ad3663b48e9669c360e2 (MD5) Previous issue date: 2016-02-24 / FACEPE / A busca por métodos que possibilitem o diagnóstico mais rápido e eficaz do infarto agudo do miocárdio é preponderante atualmente. Como possibilidade analítica mais atrativa, os imunossensores são uma grande tendência na área cardiológica. Entretanto, para o aperfeiçoamento destes dispositivos, buscam-se continuamente algumas estratégias, tais como o uso de nanomateriais e polímeros condutores com objetivo de obter uma plataforma sensora mais sensível, estável e reprodutível. Neste trabalho, um filme nanoestuturado de nanotubos de carbono e polipirrol foi desenvolvido sobre a superfície de um eletrodo de platina para detecção eletroquímica da troponina T cardíaca humana. O filme de pirrol (0,3M) e nanotubos de carbono (0,1 mg/mL) foram eletropolimerizados através da técnica de cronoamperometria (0,8 V) sobre a superfície sensora. Os grupos carboxílicos reativos do filme foram ativados para imobilização covalente dos anticorpos anti-troponina T. Os sítios livres não reativos foram bloqueados com uma solução de glicina (0,01 M). A técnica de voltametria cíclica em sonda redox foi empregada para caracterização do processo de construção da plataforma sensora. Nos resultados obtidos, a eletrossíntese do pirrol em conjunto com os nanotubos apresentou um aumento significativo na transferência de elétrons. O tempo de polimerização do filme sobre a interface do eletrodo foi otimizado quando o ensaio croamperométrico foi programado para 80 s no potencial de 0,8 V. O filme de pirrol e nanotubos apresentou uma boa estabilidade eletroquímica, com coeficientes de variação para os picos redox ≤ 5%. Uma vez confirmada à viabilidade do filme, ensaios para otimização da concentração do anticorpo imobilizado, tempo de imunoreação e transferência de carga foram realizados. Uma curva de calibração foi obtida para quantificação livre de marcação da troponina T em amostras limpas, utilizando a técnica de voltametria de pulso diferencial. O imunossensor alcançou uma boa linearidade (r=0,94; p<0,0001) com erro relativo menor do que 1%, apresentando um limite de detecção de 0,006 ng/mL para cTnT. Com a metodologia proposta foi possível desenvolver um filme nanoestruturado em uma única etapa de síntese para determinação da troponina T humana em níveis de importância clínica. / The search for methods that allow the fast and effective diagnosis of acute myocardial infarction is currently preponderant. As a more attractive analytical possibility, the immunosensors are a big trend in the field of cardiology. However, for the improvement of these devices, the search for some strategies such as the use of nanomaterials and conducting polymers is continuous in order to obtain a more sensitive, stable and reproducible sensor platform. In this work, a nanostructured film of carbon nanotubes and polypyrrole was developed on the surface of a platinum electrode for electrochemical detection of human cardiac troponin T. The pyrrole film (0.3M) and carbon nanotubes (0.1 mg/mL) were electropolymerized using the chronoamperometry technique (0.8 V) on the sensor surface. The reactive carboxylic groups of the film were activated for the covalent immobilization of anti-troponin T. The non-reactive free sites were blocked with a solution of glycine (0.01 M). The cyclic voltammetry technique in redox probe was used to characterize the process of construction of the sensor platform. In the results, the electrosynthesis of pyrrole in conjunction with the nanotubes had a increase in the electron transfer. The film’s polymerization time over the electrode interface was optimized when the chronoamperometric test was set to 80 s in the potential of 0.8 V. The pyrrole and nanotube film exhibited good electrochemical stability, with variation coefficients for the redox peaks ≤ 5%. Once confirmed the viability of the film, testing for optimization of the immobilized antibody concentration, immunoreaction time and charge transfer were performed. A calibration curve was obtained for quantification of the marking free troponin T in clean samples, using the technique of voltammetry differential pulse. The immunosensor achieved a good linearity (r = 0.94, p <0.0001) with less than 1% relative errors, presenting a detection limit of 0.006 ng/mL for cTnT. With the proposed methodology has been possible to develop a nanostructured film in a one-step synthesis for determination of human cardiac troponin T at clinical importance levels.
2

A onda Q do eletrocardiograma no diagnostico do infarto do miocardio : confronto anatomo-eletrocardiografico em 140 casos com necropsia

Teixeira, Maria Aparecida Barone, 1955- 12 August 2018 (has links)
Orientadores: Silvio dos Santos Carvalhal, Eros Antonio de Almeida / Tese (doutorado) - Universidade Estadula de Campinas, Faculdade de Ciências Medicas / Made available in DSpace on 2018-08-12T00:13:12Z (GMT). No. of bitstreams: 1 Teixeira_MariaAparecidaBarone_D.pdf: 9939891 bytes, checksum: 855055f4a4ae124f3530069ab4fefa54 (MD5) Previous issue date: 1994 / Resumo: A relação entre a presença da onda Q no eletrocardiograma(ECG) e a presença de necrose miocárdica não é absoluta. Casos falso-positivos e casos falso-negativos são relatados na literatura desde o início do século. Em face das controvérsias existentes na li teratura sobre o comportamento anormal da onda Q no ECG de pacientes com infarto do miocárdio (1M) , e sem nos afastarmos do interesse particular de aferir quadros da semiótica física ou complementar, através da anatomia patológica, é que decidimos verificar o resultado de um confronto anátomo-eletrocardiográfico, usando a necrópsia como um meio de decidir o valor do ECG nesses casos. Foram estudados 140 casos que foram distribuídos em 3 grupos: Grupo I no qual o diagnóstico eletrocardiográfico de 1M foi confirmado pela necrópsia; Grupo 11 no qual o diagnóstico eletrocardiográfico de 1M não foi confirmado pela necrópsia e Grupo 111 no qual havia diagnóstico anátomo-patológico de 1M sem diagnóstico eletrocardiográfico prévio. No GI obtivemos casos(34,28%) ; no GIl, 17 casos(12,14%) e no GIII 88 casos(62,58%). Somando os casos de cada grupo eles perfazem 153, porque em 13 casos apareceram aI terações eletrocardiográficas e anátomo-patológicas que permitiram sua inclusão em mais de um grupo. Os fatores que mais influíram no comportamen to da onda Q anormal do ECG foram: a presença de distúrbio de condução, a localização, a idade o tamanho do 1M e a sua localização na espessura da parede do VE. Assim, a onda Q anormal do ECG para o diagnóstico de 1M tem valor apenas relativo, quando ela é considerada sem o quadro clínico, exame físico e outros exames complementares. A necrópsia continua sendo método de grande importância para aferir o ECG tradicional, bem como toda semiotécnica física e laboratorial / Abstract: The relationship between the presence of Q wave at electrocardiograrn (ECG) and the presence of myocardic necrosis is not absol u te. False-posi ti ve and false-negati ve cases have been reported in literature since the beginning of this century. Literature presents controversies about the abnormal behavior of Q wave at ECG from patients wi th myocardial infarction (MI) . Since our main aim is to corroborate the pictures of physical or complemental semiotics through pathological anatomy, we decided to verify the result of a anatomoelectrocardiographic comparison. 140 cases were studied and they were divided into 3 groups: Group I, in which electrocardiographic diagnosis of MI was confirmed by necropsy; Group I I, in which i t was not confirmed; and Group III, in which there was an anatomicopat hologic diagnosis of MI without previous electrocardiographic diagnosis. GI included 48 cases(34,28%); GII 17 cases(12,14%) and GIII 88 (62,58%) . The total cases were 153 since 13 of them were included in more than one group as they presented electrocardiographic and anatomopathological changes. The most influent factors on the behavior of the abnormal Q wave of ECG were presence of conduction disturbance, localization, age, size of MI and its position at the thickness of left ventricle wall. Thus, when considered without clinical picture, physical exarnination and other complemen.tal exarninations, the abnormal Q wave of ECG has only a relative value for diagnosis of MI. Necropsy is still a very important method for corroborating traditional ECG, as well as all physical and laboratorial semiothecnics / Doutorado / Clinica Medica / Doutor em Clínica Médica
3

Calculo da fração de ejeção do ventriculo esquerdo utilizando contagens radioativas miocardicas

Ramos, Celso Darío, 1964- 14 May 2002 (has links)
Orientador : Edwaldo E. Camargo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-01T19:32:27Z (GMT). No. of bitstreams: 1 Ramos_CelsoDario_D.pdf: 15222234 bytes, checksum: 55e34382ab014dd21d374e89b09baacc (MD5) Previous issue date: 2002 / Resumo: A análise da função cardíaca em conjilllto com o estudo da perfusão miocárdica pode ter grande importânciano tratamento, acompanhamentoe avaliação prognóstica dos pacientes portadores de coronariopatia crônica. Várias técnicas foram descritas para a medida da fração de ejeção do ventrículo esquerdo (FEVE) utilizando imagens sincronizadasplanas e tomográficas de sestamibi-99mTc. A grande maioria dessas técnicas utiliza métodos geométricospara o cálculo da fração de ejeção (FE) a partir da delimitação anatômica das paredes do ventrículo esquerdo (VE)...Observação: O resumo, na integra, podera ser visualizado no texto completo da tese digital / Abstract: The simultaneous assessment of myocardial perfusion and function may be of great importance for prognosticationand management decision making in patients with coronary artery disease. Several techniques have been described for measuring left ventricular ejection fraction (LVEF) using planar and tomographic 9mTc-sestamibi images. The majority of these techniques is based on geometric methods for ejection fraction (EF) calculation and uses different techniques for the anatomical delineationof the endocardial borders of the left ventricle (LV)...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Ciências Médicas
4

Avaliação da dose de radiação: angiotomografia coronariana - métodos retrospectivo e prospectivo

Braghini, André Luís 28 May 2015 (has links)
O objetivo deste estudo foi avaliar a dose efetiva de radiação nos exames de CCTA através dos métodos Prospectivo e Retrospectivo do ECG. A coleta de dados foi realizada na Clínica Sabedotti, em Ponta Grossa – PR, em um equipamento General Electric modelo VCT XT, de 64 linhas de detecção. A dose efetiva foi mensurada para 30 casos, selecionados aleatoriamente do Picture Archival and Communication System – PACS, Arquivamento e Comunicação de Imagens, a partir do Produto Dose Comprimento (DLP) reportado pelo equipamento para cada exame e pelo fator de conversão (EDLP) definido pela Comissão Europeia para região cardíaca (EDLP = 0,014). Os resultados apontaram diferenças expressivas quanto à dose de radiação entregue ao paciente de acordo com o método de aquisição empregado, Retrospectivo ou Prospectivo do ECG. / The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
5

Avaliação da dose de radiação: angiotomografia coronariana - métodos retrospectivo e prospectivo

Braghini, André Luís 28 May 2015 (has links)
O objetivo deste estudo foi avaliar a dose efetiva de radiação nos exames de CCTA através dos métodos Prospectivo e Retrospectivo do ECG. A coleta de dados foi realizada na Clínica Sabedotti, em Ponta Grossa – PR, em um equipamento General Electric modelo VCT XT, de 64 linhas de detecção. A dose efetiva foi mensurada para 30 casos, selecionados aleatoriamente do Picture Archival and Communication System – PACS, Arquivamento e Comunicação de Imagens, a partir do Produto Dose Comprimento (DLP) reportado pelo equipamento para cada exame e pelo fator de conversão (EDLP) definido pela Comissão Europeia para região cardíaca (EDLP = 0,014). Os resultados apontaram diferenças expressivas quanto à dose de radiação entregue ao paciente de acordo com o método de aquisição empregado, Retrospectivo ou Prospectivo do ECG. / The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
6

Classificação automática de cardiopatias baseada em eletrocardiograma

Bueno, Nina Maria 30 October 2006 (has links)
This work is dedicated to study of the recognition and classification of cardiac disease, diagnosised through the electrocardiogram ECG. This examination is normally used in heart medical center, emergency, intensive therapy, and with complement diagnosis in heart disease as: acute myocardium infarction, bundle block branches, hypertrophy and others. The software was developed for support to the model, with focus on extraction of ECG signal characteristics, and an artificial neural network for recognition of diseases. For extraction these characteristics, we have used a auto-regressive model, AR, with the algorithm least mean square LMS, to minimize the minimum error. The neural network, with architecture multilayer perceptron and back propagation algorithm of training, was chosen for the recognition of the standards. The method was showed efficient. / Este trabalho dedica-se ao estudo do reconhecimento e classificação de cardiopatias, diagnosticadas através do exame de eletrocardiografia, ECG. Esse exame é comumente utilizado em visitas a cardiologistas, centros de emergência, centros de terapia intensiva e exames eletivos para auxílio de diagnóstico de cardiopatias como: infarto agudo do miocárdio, bloqueios de ramos, hipertrofia e outros. O aplicativo desenvolvido para apoio ao trabalho focaliza a extração de características do sinal ECG, representado por ciclos e a aplicação destas características a uma rede neural artificial para reconhecimento das cardiopatias. Para extração das características do sinal, utilizamos o modelo matemático de previsão de comportamento de curvas, chamado de auto-regressivo, AR, onde utilizamos o passado histórico recente da curva para determinar o próximo ponto; em nosso caso, utilizamos o algoritmo dos mínimos quadrados para adequação do erro, conhecido como LMS. A rede neural de topologia perceptron multicamadas e com algoritmo de treinamento backpropagation foi escolhida para o reconhecimento dos padrões, pela sua capacidade de generalização. O método se mostrou adequado e eficiente ao objetivo proposto. / Mestre em Ciências

Page generated in 0.0744 seconds