• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 15
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Descrição osteológica de materiais pós-cranianos de dois cinodontes não-mamalianos do meso/neotriássico (formação santa maria, bacia do paraná) do Rio Grande do Sul, Brasil

Oliveira, Téo Veiga de January 2006 (has links)
Na presente dissertação, foram descritos materiais pós-cranianos de dois cinodontes não-mamalianos (Therapsida, Cynodontia) do Triássico sul-rio-grandense (Bacia do Paraná, Formação Santa Maria). Os espécimes descritos (UFRGS PV-0146-T, um chiniquodontídeo, e UFRGS PV-0715-T, um traversodontídeo) representam ramos distintos na evolução dos cinodontes (Probainognathia e Cynognathia, com os chiniquodontídeos pertencendo ao primeiro grupo e estando mais intimamente relacionados ao surgimento dos mamíferos). A comparação entre estes dois espécimes e os cinodontes já descritos na literatura não mostrou a presença de nenhum padrão que pudesse ser aplicado ao esqueleto pós-craniano das duas linhagens por eles representadas. Por vezes, o chiniquodontídeo mostrou similaridades anatômicas com táxons de Cynognathia e o traversodontídeo apresentou aspectos mais similares aos Probainognathia. O fato de os dois espécimes estudados apresentarem semelhanças morfológicas com táxons filogeneticamente não muito próximos e diferenças em relação à táxons mais estreitamente vinculados indica a ocorrência de inúmeras homoplasias na evolução dos cinodontes e mostra que a interpretação das relações filogenéticas entre estes animais (e sua implicação mais significativa, a que diz respeito ao surgimento e à evolução dos mamíferos) deve ser tratada com extremo cuidado, uma vez que homoplasias certamente ocorrem também no esqueleto sincraniano e na dentição, nos quais estão baseadas as hipóteses filogenéticas mais usuais.
2

Descrição osteológica de materiais pós-cranianos de dois cinodontes não-mamalianos do meso/neotriássico (formação santa maria, bacia do paraná) do Rio Grande do Sul, Brasil

Oliveira, Téo Veiga de January 2006 (has links)
Na presente dissertação, foram descritos materiais pós-cranianos de dois cinodontes não-mamalianos (Therapsida, Cynodontia) do Triássico sul-rio-grandense (Bacia do Paraná, Formação Santa Maria). Os espécimes descritos (UFRGS PV-0146-T, um chiniquodontídeo, e UFRGS PV-0715-T, um traversodontídeo) representam ramos distintos na evolução dos cinodontes (Probainognathia e Cynognathia, com os chiniquodontídeos pertencendo ao primeiro grupo e estando mais intimamente relacionados ao surgimento dos mamíferos). A comparação entre estes dois espécimes e os cinodontes já descritos na literatura não mostrou a presença de nenhum padrão que pudesse ser aplicado ao esqueleto pós-craniano das duas linhagens por eles representadas. Por vezes, o chiniquodontídeo mostrou similaridades anatômicas com táxons de Cynognathia e o traversodontídeo apresentou aspectos mais similares aos Probainognathia. O fato de os dois espécimes estudados apresentarem semelhanças morfológicas com táxons filogeneticamente não muito próximos e diferenças em relação à táxons mais estreitamente vinculados indica a ocorrência de inúmeras homoplasias na evolução dos cinodontes e mostra que a interpretação das relações filogenéticas entre estes animais (e sua implicação mais significativa, a que diz respeito ao surgimento e à evolução dos mamíferos) deve ser tratada com extremo cuidado, uma vez que homoplasias certamente ocorrem também no esqueleto sincraniano e na dentição, nos quais estão baseadas as hipóteses filogenéticas mais usuais.
3

Descrição osteológica de materiais pós-cranianos de dois cinodontes não-mamalianos do meso/neotriássico (formação santa maria, bacia do paraná) do Rio Grande do Sul, Brasil

Oliveira, Téo Veiga de January 2006 (has links)
Na presente dissertação, foram descritos materiais pós-cranianos de dois cinodontes não-mamalianos (Therapsida, Cynodontia) do Triássico sul-rio-grandense (Bacia do Paraná, Formação Santa Maria). Os espécimes descritos (UFRGS PV-0146-T, um chiniquodontídeo, e UFRGS PV-0715-T, um traversodontídeo) representam ramos distintos na evolução dos cinodontes (Probainognathia e Cynognathia, com os chiniquodontídeos pertencendo ao primeiro grupo e estando mais intimamente relacionados ao surgimento dos mamíferos). A comparação entre estes dois espécimes e os cinodontes já descritos na literatura não mostrou a presença de nenhum padrão que pudesse ser aplicado ao esqueleto pós-craniano das duas linhagens por eles representadas. Por vezes, o chiniquodontídeo mostrou similaridades anatômicas com táxons de Cynognathia e o traversodontídeo apresentou aspectos mais similares aos Probainognathia. O fato de os dois espécimes estudados apresentarem semelhanças morfológicas com táxons filogeneticamente não muito próximos e diferenças em relação à táxons mais estreitamente vinculados indica a ocorrência de inúmeras homoplasias na evolução dos cinodontes e mostra que a interpretação das relações filogenéticas entre estes animais (e sua implicação mais significativa, a que diz respeito ao surgimento e à evolução dos mamíferos) deve ser tratada com extremo cuidado, uma vez que homoplasias certamente ocorrem também no esqueleto sincraniano e na dentição, nos quais estão baseadas as hipóteses filogenéticas mais usuais.
4

Estudo de pacientes submetidos a profilaxia antiepiléptica após cirurgia para traumatismo craniencefálico

LIMA JUNIOR, Ezir Araújo 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T22:59:59Z (GMT). No. of bitstreams: 2 arquivo4223_1.pdf: 1952154 bytes, checksum: fe89726976e9e37849515a1a3be14c11 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Introdução: A crise epiléptica após cirurgia neurológica para trauma craniencefálico, derivada de vasoespasmos sintomáticos ou de lesões corticais, pode aumentar a agressão ao tecido nervoso devido a alterações metabólicas. A conduta clínica para essas crises epilépticas ainda suscita controvérsia quanto à instituição do tratamento, assim como a melhor droga antiepiléptica, o tempo e a dose ideal. Objetivos: O primeiro objetivo dessa dissertação foi discutir os aspectos controversos relativos ao uso dos fármacos antiepilépticos após intervenções neurocirúrgicas para traumatismo craniencefálico. O segundo objetivo foi comparar as características pré-operatórias, pós-operatórias e de seguimento por 12 a 24 meses de pacientes submetidos a procedimentos neurocirúrgicos por traumatismo craniencefálico segundo profilaxia antiepiléptica. Métodos: Essa dissertação esteve composta por dois artigos. No primeiro, sob título Profilaxia anticonvulsivante em traumatismo craniencefálico grave, empregou-se uma revisão sistemática, incluindo 28 artigos sob forma de estudos aleatorizados, duplos cegos, revisões sistemáticas e metanálises, publicados entre 1973 e 2009, nas bases de dados Bireme, Lilacs, Scopus e Medline. No segundo artigo, sob título Avaliação do uso profilático de anticonvulsivantes em pacientes com traumatismo craniencefálico grave submetidos a tratamento cirúrgico, realizou-se estudo retrospectivo, tipo série de casos, com base em dados secundários ad hoc , envolvendo 278 pacientes submetidos a procedimento neurocirúrgico por trauma craniencefálico no período de Agosto a Dezembro de 2006, que não apresentavam história prévia de epilepsia ou diagnóstico cirúrgico de malformação arteriovenosa, abscesso cerebral ou tumores intracranianos; alterações hematológicas ou hepáticas que contraindicassem o uso de fármacos antiepilépticos, diagnosticadas por exames laboratoriais, e que aderiram ao acompanhamento pós-operatório por 12 a 24 meses, comparecendo a consultas ambulatoriais. Os pacientes foram divididos em dois grupos não aleatorizados segundo as variáveis de interesse relativas a profilaxia farmacológica de crises epilépticas durante o internamento e lesão cortical superficial ou profunda/transventricular, de tal forma que 77 (27,7%) integraram o grupo não tratado profilaticamente e 201 (72,3%), o grupo tratado profilaticamente. Resultados: No primeiro artigo, identificou-se que o questionamento reside na relação custo/benefício do tratamento profilático das crises epilépticas no pós-operatório, porque a prevenção expõe o paciente ao risco de efeitos colaterais e adversos dos fármacos antiepilépticos. No segundo artigo, constatou-se que a incidência global de crises epilépticas durante o internamento igualou-se a 20,1%, sendo 16,5% crises precoces, 3,6% tardias, e 25,9% no acompanhamento ambulatorial. Identificou-se que, independente das características neurocirúrgicas e da extensão da lesão cortical, os pacientes submetidos à profilaxia de crises com fármacos antiepilépticos obtiveram menores pontuações na escala de Karnofsky e de resultados de Glasgow, assim como mais frequentemente não retornaram ao trabalho anterior ao neurotrauma. Conclusão: A profilaxia com fármacos antiepilépticos deve ser empregada apenas a casos selecionados e por período menor que o da presente pesquisa, para evitar efeitos deletérios em longo prazo
5

Estudo comparativo da reprodutibilidade do arco facial e de um novo dispositivo com nível de bolha para montagem de modelos maxilares em articulador semi-ajustável / Comparative study of the reproducibility of the face bow and a new bubble level device for mounting maxillary casts semi-adjustable articulator

Cintra, Marina de Godoy Almeida 28 April 2015 (has links)
O arco facial tem seu uso descrito na literatura desde o início do século 20, e atualmente sua eficácia e precisão são controversas. Publicações recentes mostram que a sua reprodutibilidade é passível de erros. Este estudo teve como objetivo comparar a reprodutibilidade do arco facial com a de um novo dispositivo desenvolvido com nível de bolha para a montagem de modelos de gesso em articuladores semi-ajustáveis, por meio da análise de medidas realizadas com a Mesa de Erickson. Os modelos de gesso foram obtidos com moldes de alginato e montados em articulador semi-ajustável marca Bio-art, modelo a7 Plus. A avaliação da reprodutibilidade foi realizada em 10 participantes, com a obtenção de três montagens de seus modelos maxilares, sendo a primeira com o arco facial, a segunda com o dispositivo com nível de bolha estando o participante sentado e a terceira com o dispositivo com nível de bolha estando o participante em pé, cada método foi aferido 3 vezes, por 3 examinadores diferentes. Para cada montagem foram realizadas cinco medidas a saber: a) nas cúspides dos primeiros molares superiores de cada lado (dentes 16 e 26), b) cúspides dos caninos superiores de cada lado (dentes 13 e 23) e c) ponto interincisivo, localizado na linha média. Os valores obtidos foram submetidos ao Cálculo do Erro Técnico da Medida e ao Coeficiente de Variação interexaminador. O presente trabalho concluiu que o arco facial tem uma margem de erro em medidas repetidas maior do que o novo dispositivo desenvolvido. O novo dispositivo mostrou-se mais confortável para os participantes, mas necessita mais testes para avaliarmos sua eficiência. / The face bow has been described in the literature since the early 20th century, and currently its effectiveness and accuracy are controversial. Recent publications show that the reproducibility is error-prone. This study aimed to compare the reproducibility of the face bow with a new device developed with bubble level for the assembly of plaster models in semi-adjustable articulators, through the analysis of measurements performed with Erickson table. The plaster models were obtained with alginate molds and mounted on semi-adjustable articulator brand Bio-art, a7 Plus model. Evaluation of reproducibility was conducted in 10 participants, obtaining three assemblies of their maxillary casts, the first one with the face bow, the second with the bubble level device with the participant being seated and the third level with the device bubble being the participant standing, each method was measured 3 times by 3 different examiners. For each assembly five measurements were performed as follows: a) in the cusps of the upper first molars on each side (teeth 16:26), b) cusps of upper canines on each side (teeth 13:23) and c) interincisal point, located in midline. The values obtained were subjected to measurement of the Technical Error Calculation and inter Coefficient of Variation. This study concluded that the face bow has a margin of error in repeated measurements greater than the newly developed device. The new device was more comfortable for the participants, but it needs more testing to evaluate their efficiency.
6

Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomography

Martins, Elaine Wirney 10 May 2016 (has links)
Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / To determine the exposure levels and the absorbed dose in patients undergoing CT scans, is necessary to calculate the CT dose index in measurements with a PMMA or water phantom. The phantom must be enough to simulate the attenuation and scattering characteristics of a human body or parts in a radiation field. The CT specific quantities : CT air kerma index (Ca,100) , weighted CT air kerma index (CW ), a total volume CT air kerma index (Cvol) and the CT air kerma-lenght product (PKL) must be determined and compared to literature reference levels. In this work a head pediatric phantom was developed, considering that the Brazilian published Diagnostic Reference Levels (DRL) are based on adult phantom measurements. This developed phantom shows a construction innovation using materials to simulate the skullcap, cortical bone (aluminum) and cancellous bone (PVC), and it was filled with distilled water. The phantom dimension follows the recommendations of the World Health Organization and the International Commission on Radiation Units for children from 0 to 5 years old head size: diameter of 160 mm and height of 155 mm. The skullcap has 4 mm of thickness and 111.9 mm of internal diameter. In order to evaluate its behavior, tests were carried out in calibration laboratories and in clinical beams. The results showed attenuation up to 23% when different materials are used as skullcap, demonstrating that the DRLs adopted could be overestimating the dose received by pediatric patients. It is observed that the dose received by CT skull scans presents different distribution, due to the skullcap partially attenuation and/or backscattering which is not considered when the PMMA phantom is used.
7

Perfil epidemiológico dos pacientes com traumatismo crânio encefálico admitidos em uma unidade de tratamento intensivo de referência no sul do Brasil

BAINY, Marina Peres 29 June 2017 (has links)
Submitted by Cristiane Chim (cristiane.chim@ucpel.edu.br) on 2018-04-09T13:03:47Z No. of bitstreams: 1 Marina Peres Bainy.pdf: 564845 bytes, checksum: 6e321a15ba12b9d5d7cddeaf10ff5bfe (MD5) / Made available in DSpace on 2018-04-09T13:03:47Z (GMT). No. of bitstreams: 1 Marina Peres Bainy.pdf: 564845 bytes, checksum: 6e321a15ba12b9d5d7cddeaf10ff5bfe (MD5) Previous issue date: 2017-06-29 / Background: The traumatic brain injury (TBI) is one of the main causes of mortality in young-adults, which generates important social and economic impacts. Objective: To trace the epidemiological profile of victims who suffered TBI and were admitted to a Reference Intensive Care Unit in southern Brazil. Method: Documental-based and retrospective study, which had as population victims of TBI admitted to a reference ICU for trauma, in a city in the south of Brazil. All participants were eligible in the unit during the period of January 2010 to January 2017. The Glasgow Coma Scale was used to classifying the gravity of the TBI. Results: In this study, 220 charts of victims of TBI were included. The majority was male (80.9%) and averagely were 38.63 years old (+ 19.42), being the minimum age 11 years old, and maximum of 93. Regarding the gravity of TBI, according to the GCS classification, 58.20% was considered severe, 28.20% moderate, and 12.7% mild. Among the most common causes are the automobile accidents, followed to hitches, fall from heights, and urban violence. In what concerns the disclosure, 32.9% evolved to death, and 67.1% obtained clinical discharge. Conclusion: The present study evidenced that traumatic brain injury affects, in greater proportion, young-adults, males, that automobile accidents represent the main mechanism for trauma, and that the severe TBI was the most prevalent among the hospital admissions. Keywords: Traumatic brain injury, Intensive Care Unit, Epidemiology. / Introdução Globalmente, o traumatismo crânio encefálico (TCE) representa um grave problema de saúde pública, sendo responsável por alta morbidade e mortalidade, principalmente em jovens de idade produtiva e idosos. Alguns estudos reportam o TCE como uma “Epidemia Silenciosa”, pois seus efeitos catastróficos à sociedade não são imediatamente perceptíveis nem tão pouco previsíveis em sua totalidade e potencialidade, justificando a importância de investimentos em pesquisa e campanhas de prevenção voltadas a esta enfermidade. Objetivo Conhecer o perfil epidemiológico de pacientes vítimas de TCE internados em uma Unidade de Terapia Intensiva de referência no Sul do Brasil. Método Trata-se de um estudo de base documental, retrospectivo, tendo como população acessível pacientes admitidos por traumatismo crânio encefálico em internação na Unidade de Terapia Intensiva do Hospital Universitário São Francisco de Paula, da Universidade Católica de Pelotas, Rio Grande do Sul. Resultados esperados Espera-se que, através da identificação do perfil sócio demográfico destes pacientes, das causas que levaram ao trauma, das lesões neurológicas mais comumente encontradas, assim como de complicações decorrentes do TCE, realização de neurocirurgia, tempo de utilização de suporte ventilatório, tempo de internação em UTI, ocorrência de parada cardiorrespiratória, entre outras variáveis, possamos identificar lacunas de intervenção para ações de prevenção e de melhoria na qualidade assistencial.
8

Estudo comparativo da reprodutibilidade do arco facial e de um novo dispositivo com nível de bolha para montagem de modelos maxilares em articulador semi-ajustável / Comparative study of the reproducibility of the face bow and a new bubble level device for mounting maxillary casts semi-adjustable articulator

Marina de Godoy Almeida Cintra 28 April 2015 (has links)
O arco facial tem seu uso descrito na literatura desde o início do século 20, e atualmente sua eficácia e precisão são controversas. Publicações recentes mostram que a sua reprodutibilidade é passível de erros. Este estudo teve como objetivo comparar a reprodutibilidade do arco facial com a de um novo dispositivo desenvolvido com nível de bolha para a montagem de modelos de gesso em articuladores semi-ajustáveis, por meio da análise de medidas realizadas com a Mesa de Erickson. Os modelos de gesso foram obtidos com moldes de alginato e montados em articulador semi-ajustável marca Bio-art, modelo a7 Plus. A avaliação da reprodutibilidade foi realizada em 10 participantes, com a obtenção de três montagens de seus modelos maxilares, sendo a primeira com o arco facial, a segunda com o dispositivo com nível de bolha estando o participante sentado e a terceira com o dispositivo com nível de bolha estando o participante em pé, cada método foi aferido 3 vezes, por 3 examinadores diferentes. Para cada montagem foram realizadas cinco medidas a saber: a) nas cúspides dos primeiros molares superiores de cada lado (dentes 16 e 26), b) cúspides dos caninos superiores de cada lado (dentes 13 e 23) e c) ponto interincisivo, localizado na linha média. Os valores obtidos foram submetidos ao Cálculo do Erro Técnico da Medida e ao Coeficiente de Variação interexaminador. O presente trabalho concluiu que o arco facial tem uma margem de erro em medidas repetidas maior do que o novo dispositivo desenvolvido. O novo dispositivo mostrou-se mais confortável para os participantes, mas necessita mais testes para avaliarmos sua eficiência. / The face bow has been described in the literature since the early 20th century, and currently its effectiveness and accuracy are controversial. Recent publications show that the reproducibility is error-prone. This study aimed to compare the reproducibility of the face bow with a new device developed with bubble level for the assembly of plaster models in semi-adjustable articulators, through the analysis of measurements performed with Erickson table. The plaster models were obtained with alginate molds and mounted on semi-adjustable articulator brand Bio-art, a7 Plus model. Evaluation of reproducibility was conducted in 10 participants, obtaining three assemblies of their maxillary casts, the first one with the face bow, the second with the bubble level device with the participant being seated and the third level with the device bubble being the participant standing, each method was measured 3 times by 3 different examiners. For each assembly five measurements were performed as follows: a) in the cusps of the upper first molars on each side (teeth 16:26), b) cusps of upper canines on each side (teeth 13:23) and c) interincisal point, located in midline. The values obtained were subjected to measurement of the Technical Error Calculation and inter Coefficient of Variation. This study concluded that the face bow has a margin of error in repeated measurements greater than the newly developed device. The new device was more comfortable for the participants, but it needs more testing to evaluate their efficiency.
9

Para um estudo da estruturação ritmica na fala disartrica / Towards a study of the rhythmic structural in dysarthric speech

Vieira, Jussara Melo 23 February 2007 (has links)
Orientador: Plinio Almeida Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Estudos da Linguagem / Made available in DSpace on 2018-08-10T11:46:05Z (GMT). No. of bitstreams: 1 Vieira_JussaraMelo_D.pdf: 3447938 bytes, checksum: baa53bcff3e3572313562da26d96e687 (MD5) Previous issue date: 2007 / Resumo: A disartria é uma desordem da fala decorrente de comprometimentos neuromusculares. Tais comprometimentos podem causar alterações na respiração, na fonação, na ressonância e na articulação da fala. Estes comprometimentos podem ser decorrentes de traumatismo craniano (TC). O TC é uma agressão cerebral resultante de uma pancada na cabeça e/ou uma queda com fratura craniana. Na fala disártrica pode haver, também, falha no mecanismo velofaríngeo devido à paralisia/paresia do palato mole. Neste caso, o resultado acústico para a fala é a hipernasalidade e a emissão de ar nasal, que podem ser tratadas através do uso de uma prótese de palato elevadora (PPE). Na disartria, o ritmo da fala também pode estar alterado, implicando alterações nos locais de acento frasal (AF), na inserção e na duração das pausas silenciosas (PS). Sendo assim, interessou-nos investigar a estruturação rítmica da fala disártrica decorrente de TC. Para tanto, obtivemos a colaboração de uma falante disártrica, usuária de PPE, falante nativa do português brasileiro (PB) acometida por TC. O estudo desta fala isártrica teve como objetivos: comparar as condições de uso e não uso da PPE; comparar a estruturação rítmica da fala disártrica brasileira (FDB) com uma fala sem comprometimentos (FSC); comparar a estruturação rítmica da FDB com uma fala isártrica francesa (FDF); estudar a relação sintaxeprosódia na estruturação rítmica da fala tanto na comparação com a FSC quanto na comparação com a FDF; adquirir melhor entendimento da fala disártrica pós TC, considerando o modelo de ritmo da fala para o PB de Barbosa (2006). Para cumprir estes objetivos, acompanhamos o tratamento com PPE da falante disártrica de 1995 a 2005. Neste período coletamos e analisamos oito leituras de um mesmo texto realizadas por ela usando a PPE e duas leituras sem esta prótese: uma em 1995 e outra em 2005. A FSC correspondeu à leitura do mesmo texto da FDB. A FDF correspondeu à leitura de outro texto francês. Nestas leituras realizamos análises acústicas e de sua organização rítmica em unidades vogal-vogal (VV), grupos acentuais (GA), AF e PS. Nas análises das oito leituras da FDB houve redução no número de PS, redução da participação das PS na duração do texto lido e aumento da taxa de elocução (TE). A estruturação rítmica da FDB com e sem a prótese foi a mesma. Houve diferença significante entre a FDB e a FSC para a TE e para a duração das PS, mas não para a duração dos GA nem para o número de unidades VV. Na comparação entre a FDB e a FDF não houve diferenças significativas quanto à TE, taxa de articulação e número de unidades VV por GA. Na relação sintaxe-prosódia, as marcas sintáticas IDF (independência forte) e COORD (independência de uma conjunção coordenada) foram significativas tanto para a FDB quanto para a FSC. Mas não para a FDF. Nosso trabalho contribuiu para destacar a pertinência de estudos que considerem a relação dinâmica entre fatores biomecânicos e lingüísticos da fala, notadamente para a fala comprometida e, em especial, para a fala disártrica pós TC / Abstract: Dysarthria is a speech disorder caused by neuromotors problems. These neuromotors problems may cause breath, phonation, resonance and speech articulation disturbance. The cause of these neuromotors problems can be the traumatic brain injury (TBI). TBI is a lesion that result of cerebral aggression, a collision in the head/or a fall happening cranial breaking. Dysarthric speech can have too velopharyngeal dysfunction by total/partial paralysis soft palate. In case of soft palate palsy the hypernasality may be present, with emission of nasal air during oral sounds. In order to deal with hypernasality and nasal air emission a palatal lift (PL) is indicated. The use of PL stimulates the correct movement of the soft palate, which produces the appropriate closure of the velopharyngeal port. Rhythm speech can be altered in dysarthric speech. We realize then a study of the rhythmic structure of the dysarthric speech by TBI. For doing so, eight dysarthric speaker?s readings during prosthesis treatment with the palatal lift, are compared with readings without prosthesis, with a reference speaker and a French dysarthric speaker. These comparisons are done by analyzing vowel-to-vowel units (VV), stress groups, phrase stress and silent pauses under the theoretical framework of Barbosa (2006)?s speech rhythm model applied to Brazilian Portuguese. In the eight readings of the Brazilian dysarthric speaker, there were reductions on the number of silent pauses and pause occurrence. An increase of speech rate was also observed. The results showed that there is no distinction in rhythmic structure with and without prosthesis. The comparative analysis between the Brazilian dysarthric speaker and the reference speaker showed significant differences in speech rate and silent pause duration, but no significant difference in the duration of stress groups or in the number of VV units. The comparative analysis between the Brazilian dysarthric speaker and the French dysarthric speaker showed no significant differences in speech rate, articulation rate and number of VV units inside stress groups. As regards the syntax-prosody interface, the syntactic markers IDF (strong independency) and COORD (coordinated conjunction independency) were significant for both the Brazilian dysarthric and the reference speaker. However, these markers were not significant for the French dysarthric speaker. This work reinforces the importance of considering both linguistics and biomechanics aspects on the analysis of dysarthric speech / Doutorado / Doutor em Linguística
10

Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomography

Elaine Wirney Martins 10 May 2016 (has links)
Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / To determine the exposure levels and the absorbed dose in patients undergoing CT scans, is necessary to calculate the CT dose index in measurements with a PMMA or water phantom. The phantom must be enough to simulate the attenuation and scattering characteristics of a human body or parts in a radiation field. The CT specific quantities : CT air kerma index (Ca,100) , weighted CT air kerma index (CW ), a total volume CT air kerma index (Cvol) and the CT air kerma-lenght product (PKL) must be determined and compared to literature reference levels. In this work a head pediatric phantom was developed, considering that the Brazilian published Diagnostic Reference Levels (DRL) are based on adult phantom measurements. This developed phantom shows a construction innovation using materials to simulate the skullcap, cortical bone (aluminum) and cancellous bone (PVC), and it was filled with distilled water. The phantom dimension follows the recommendations of the World Health Organization and the International Commission on Radiation Units for children from 0 to 5 years old head size: diameter of 160 mm and height of 155 mm. The skullcap has 4 mm of thickness and 111.9 mm of internal diameter. In order to evaluate its behavior, tests were carried out in calibration laboratories and in clinical beams. The results showed attenuation up to 23% when different materials are used as skullcap, demonstrating that the DRLs adopted could be overestimating the dose received by pediatric patients. It is observed that the dose received by CT skull scans presents different distribution, due to the skullcap partially attenuation and/or backscattering which is not considered when the PMMA phantom is used.

Page generated in 0.0282 seconds