771 |
Anodiza??o para obten??o de membranas cer?micas / Hard anodizing to attachment of ceramic membranesTimoteo J?nior, Jos? Fl?vio 17 December 2007 (has links)
Made available in DSpace on 2014-12-17T14:57:41Z (GMT). No. of bitstreams: 1
JoseFTJ.pdf: 1695651 bytes, checksum: 0a95ed624ef6e5342ad90e1b6193878e (MD5)
Previous issue date: 2007-12-17 / This a study on the achievement of alumina membranes by the method of anodizing. From this method got up a layer of aluminum oxide on the anodic metal, who presented the basic
properties necessary for the application as a support for the production and acquisition of nanomaterials, such as porosity nano and resistance to high temperature, and other properties, as resistance to corrosion, and chemical, high ranking of the structure and pore size of the pores. The latter, ranging from 10 to 100nm depended on the electrolyte used, which in this study was the H2SO4. To remove all remaining aluminum, it is a bath of dissolution with HCl
and CuCl where the residual aluminum has been withdrawn, and the deep pores were opened after chemical treatment with NaOH. After the dissolution, the membranes were calcined at temperatures of 300, 600 and 900? C, and sintered at temperatures of 1200 and 1300? C to win
mechanical strength, porosity and observe the desired crystallization. Then went through analyses of composition through X-ray diffraction and morphology of the microstructure
through a scanning electron microscope. The method was effective for obtaining alumine membranes applied in the processes of production of materials in nano / Trata de um estudo sobre a obten??o de membranas de alumina atrav?s do m?todo da anodiza??o. A partir deste m?todo obteve-se uma camada de ?xido an?dico sobre o alum?nio met?lico, que apresentou as propriedades b?sicas necess?rias ? aplica??o como suporte para produ??o e obten??o de nanomateriais, tais como: porosidade nanom?trica e resist?ncia a altas temperaturas, al?m de outras propriedades, como resist?ncia ? corros?o, e qu?mica, alta ordena??o da estrutura dos poros e tamanho dos poros. Este ?ltimo, variando de 10 at? 100nm dependeu do eletr?lito usado, o qual neste estudo foi o H2SO4. Para retirar todo alum?nio restante, procedeu-se um banho de dissolu??o com HCl e CuCl no qual o alum?nio residual foi retirado, e os poros profundos foram abertos ap?s o tratamento qu?mico com NaOH. Ap?s a dissolu??o, as membranas foram calcinadas nas temperaturas de 300, 600 e 900? C, e sinterizadas nas temperaturas de 1200 e 1300? C para ganhar resist?ncia mec?nica, porosidade desejada e observar a cristaliza??o. Em seguida passou por an?lises de composi??o atrav?s da
Difra??o de Raios-X e morfologia da microestrutura por meio de um microsc?pio eletr?nico de varredura. O m?todo se mostrou eficiente para obten??o de membranas de alumina
aplicadas nos processos de produ??o de materiais em escala nanom?trica
|
772 |
Texturização superficial eletroquímica sem mascaramento com finalidades tribológicas / Maskless electrochemical texturing surfaces for tribological purposesParreira, Jakeline Guimarães 28 February 2011 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Surface texturing can be used to improve the tribological performance of mechanical
contacts, in particular in the case of lubricated systems. The purpose of this work is to
improve an alternative method for surface texturing based on electrochemical machining.
Electrochemical dissolution combines high speed, good reproducibility and high cost-benefit
ratio, which are important factors when an industrial application of surface texturing is
pursued. Since the area to be textured is not required to be masked, the technique is
optimized, without the need of a pre or post treatment of each surface. Another nonconventional
machining technique, Electrical Discharge Machining (EDM), was used to drill
microholes in the cover of the tool that will be used in the microtexturing operations. The
pattern of microholes in the tool is copied onto the workpiece through the action of
electrochemical dissolution. The improvement of the electrochemical texturing technique was
achieved with the design of an electronic circuit with a data acquisition system and of an
electrochemical cell and with the specification of the electrolyte pumping system, which
improved the surface finish of the textured workpiece, as well as with the development of
tools that made possible the confection of different microtexture patterns. In the
electrochemical cell, the tool material was AISI 230 ferritic stainless steel and the workpiece
material was carbon steel AISI 1010o. Sodium Chloride was chosen as the electrolyte tool
makes the electrical contact between the electrodes. During the electrochemical texturing
tests, the effect of important parameters such as the gap between electrodes, the applied
voltage and the total texturing time were evaluated, and the best values found were a gap of
100 mm, a voltage between 30V and 40V and a texturing time between 20s and 60s.
Different texturing patterns were obtained with good results, including dots, trace-dots and
chevrons. A tribological test showed a reduction in friction and wear of a textured surface
lubricated with MoS2, when compared with a smooth surface. / A texturização superficial pode ser utilizada para melhorar o desempenho tribológico de
contatos mecânicos, em particular em regimes lubrificados. O presente trabalho tem o
objetivo de aprimorar uma metodologia alternativa para a texturização de superfícies
baseada em princípios de usinagem eletroquímica. A dissolução eletroquímica alia rapidez,
reprodutibilidade e elevado custo-benefício, que são extremamente importantes quando se
visa a aplicação da microtexturização em escala industrial. O não mascaramento da área a
ser texturizada otimiza a técnica, dispensando um tratamento prévio e posterior de cada
superfície. Uma técnica também não convencional de usinagem, a eletroerosão, foi utilizada
para a microfuração da tampa da ferramenta a ser usada na microtexturização. O padrão de
microfuração da ferramenta é copiado à peça pela ação da dissolução eletroquímica. O
aprimoramento da técnica de texturização eletroquímica foi acompanhado pelo projeto de
um circuito eletrônico com sistema de aquisição de dados, de uma célula eletroquímica e
pelo dimensionamento de um sistema para bombeamento e fluxo de eletrólito, que
permitiram uma melhora no acabamento superficial das peças microtexturizadas, além do
desenvolvimento de ferramentas que viabilizaram a confecção de diferentes padrões de
microtexturização. Na célula de texturização eletroquímica, o material da ferramenta foi o
aço inoxidável ferrítico AISI 430 e o da peça foi o aço carbono 1010. O eletrólito escolhido
para promover o contato elétrico entre os eletrodos foi o NaCl. Durante a texturização
eletroquímica foram avaliados parâmetros importantes como o distanciamento entre
eletrodos, a tensão aplicada e o tempo total de texturização, sendo que os melhores
resultados foram obtidos para um distanciamento de 100 mm, uma tensão de 30 a 40 V e um
tempo de texturização entre 20 e 60 s. Foram texturizados ainda padrões com formatos de
ponto, traço-ponto e V , obtendo-se bons resultados. Um teste tribológico mostrou uma
redução do atrito e uma diminuição do desgaste de uma superfície texturizada lubrificada
com MoS2, quando comparada com uma superfície lisa. / Mestre em Engenharia Mecânica
|
773 |
Influência da adição de tensoativos nas propriedades dos hipocloritos de sódio e cálcio / Influence of surfactants addition on the properties of sodium and calcium hypochloriteIglesias, Julia Eick January 2016 (has links)
O objetivo do presente estudo foi o de avaliar a influência da associação dos tensoativos cetrimida 0,2%, cetrimida 0,1% e cloreto de benzalcônio 0,008% aos hipocloritos de sódio e de cálcio 2,5% nas propriedades de pH, quantidade de cloro livre, tensão superficial, ângulo de contato, dissolução pulpar e atividade antimicrobiana. O pH e a concentração de cloro ativo foram avaliados por pHmetro digital e pela titulação, respectivamente. A tensão superficial foi mensurada através da técnica do anel de platina com um tensiômetro de Du Noüy. O ângulo de contato das soluções em bases de dentina humana foi aferido pelo software Drop Shape Analyzer. Para a análise da dissolução pulpar foram utilizados fragmentos de polpas bovinas e os resultados foram expressos por percentual de perda de massa. A atividade antimicrobiana frente ao Enterococcus faecalis foi realizada pelo método de difusão em Ágar. Os resultados mostraram que a associação de tensoativos aos hipocloritos de sódio e cálcio não alterou as propriedades de pH, cloro livre e dissolução pulpar das soluções. O hipoclorito de cálcio apresentou o maior valor de tensão superficial (72,13 ± 1,82 mN/m). Quando associados aos tensoativos, os hipocloritos de sódio e cálcio tiveram uma redução significativa da tensão superficial. O mesmo foi observado para o ângulo de contato. Os tensoativos apresentam atividade antimicrobiana. A associação dos hipocloritos à cetrimida 0,2% ou 0,1% aumentou o halo de inibição frente ao Enterococcus faecalis. Concluiu-se que a associação de tensoativos não modificaram as propriedades de pH, cloro livre e dissolução pulpar dos hipocloritos de sódio e cálcio 2,5%. Porém, ela foi capaz de diminuir a tensão superficial e o ângulo de contato das soluções. Ainda, a associação da cetrimida 0,2% e 0,1% melhorou a capacidade antimicrobiana dos hipocloritos. / The aim of this study was to evaluate the influence of surfactants 0,2% or 0,1% cetrimide or 0,008% benzalkonium chloride on 2.5% sodium and calcium hypochlorite in the properties of pH, free chlorine content, surface tension, contact angle, pulp dissolution and antimicrobial activity. The pH and free chlorine content were evaluated by digital pHmeter and by titration, respectively. Surface tension was measured by the platinum ring technique with a Du Noüy tensiometer. Solution’s contact angle in human dentin surfaces was checked by Drop Shape Analyzer software. Bovine pulps were used for pulp dissolution analysis and the dissolving capacity was expressed by percentual weight loss. Antimicrobial activity over Enterococcus faecalis was evaluated through the ágar diffusion method. The surfactants association on sodium and calcium hypochlorites did not alter pH, free chlorine content and pulp dissolution properties. Calcium hypochlorite had the higher surface tension (72,13 ± 1,82 mN/m). However, when sodium and calcium hypochlorite were associated to surfactants, a significant reduction of surface tension occured. The same was observed for contact angle analysis. The surfactants used in this study have antimicrobial activity. The association of 0,2% or 0,1% cetrimide enhanced antimicrobial activity of both hypochlorites. It was possible to conclude that surfactants association did not alter pH, free chlorine content and pulp dissolution properties of 2,5% sodium and calcium hypochlorite. It was capable to reduce surface tension and contact angle of the solutions. Moreover, the 0,2% or 0,1% cetrimide association increased antimicrobial activity of hypochlorite.
|
774 |
Métodos analíticos para determinação de delapril e manidipino aplicáveis a estudos de estabilidade e ao desenvolvimento de método de dissolução para a forma farmacêutica comprimidosTodeschini, Vítor January 2013 (has links)
A associação entre os fármacos delapril (DEL) e manidipino (MAN) apresenta um efeito anti-hipertensivo sinérgico de longa duração, sendo considerada uma importante alternativa no tratamento e controle da hipertensão arterial. O presente trabalho faz referência à utilização de diversas técnicas instrumentais para avaliar a qualidade de DEL e MAN na forma farmacêutica e matérias-primas. Neste sentido, amostras de matérias-primas dos fármacos provenientes de diferentes fornecedores foram analisadas utilizando a calorimetria diferencial exploratória, termogravimetria, difração de raios X, espectrofotometria no infravermelho, espectroscopia Raman e microscopia eletrônica de varredura. Os resultados permitiram observar inconsistências entre as amostras de DEL, provavelmente devido à presença de uma impureza em uma das substâncias, demonstrando a importância da pesquisa e controle dos insumos farmacêuticos, bem como de programas de qualificação de fornecedores. Além disso, metodologias analíticas por espectrofotometria derivada, cromatografia líquida com detecção no ultravioleta (CL-UV) e CL acoplada à espectrometria de massas (EM) foram desenvolvidas objetivando a determinação de DEL e MAN nos comprimidos. Os procedimentos foram validados, cumprindo com os requisitos internacionalmente aceitos para especificidade, linearidade, precisão, exatidão, robustez e limites de detecção e quantificação, além de demonstrarem diferença não significativa (p > 0,05) entre si na quantificação simultânea dos fármacos. A estabilidade dos fármacos nas condições alcalina e fotolítica (para o DEL e MAN, respecivamente) também foi investigada. Através dos métodos por CL-UV e CL-EM pode-se propor a identidade dos principais produtos de degradação formados, os quais não apresentaram evidências de citotoxicidade em estudo utilizando células mononucleares humanas. Além disso, os estudos de cinéticas de degradação indicaram que o DEL segue uma cinética de primeira ordem (R2 = 0,9991) enquanto o MAN segue uma reação de ordem zero (R2 = 0,9867). De forma adicional, foi desenvolvido e validado um método de dissolução para avaliação de comprimidos contendo DEL e MAN. O uso de tampão citrato pH 3,2 como meio de dissolução e dispositivo pá a 75 rpm demonstrou resultados satisfatórios para a avaliação da liberação simultânea dos fármacos do produto farmacêutico, bem como capacidade de simular o comportamento in vivo do MAN a partir de dados da literatura. Desse modo, estabeleceram-se procedimentos analíticos que podem ser aplicados para aprimorar o controle da qualidade dos medicamentos a serem comercializados, bem como contribuir para garantir a segurança e eficácia no uso terapêutico. / The association of delapril (DEL) and manidipine (MAN) has a synergic antihypertensive effect and may be regarded as an important alternative to arterial hypertension treatment. The present study refers to use of some instrumental techniques to assess the quality of DEL and MAN in pharmaceutical formulation and raw materials. In this context, samples of the drugs raw materials, obtained from different suppliers, were evaluated using differential scanning calorimetry, thermogravimety, X-ray powder diffraction, infrared spectroscopy, Raman spectroscopy and scanning electron microscopy. Inconsistent results were observed between DEL samples, probably due to an impurity presence in some substance, demonstrating the importance of research and control of pharmaceutical ingredients, as well as the quality programs of pharmaceuticals suppliers. In addition, a derivative spectrophotometric, liquid chromatography (LC) and LC coupled to mass spectrometry (MS) methods were developed for simultaneous analysis of DEL and MAN in commercial tablets. The procedures were validated and the results were in accordance with internationally accepted requirements by specificity, linearity, precision, accuracy, robustness and detection and quantitation limits. Therefore, the methods were successfully applied for the simultaneous quantitative analysis of DEL and MAN in the tablet dosage form, showing non-significant difference (p > 0.05). The drugs stability in alkaline and photolytic conditions (for DEL and MAN, respectively) was also investigated. The main degradation products formed were analyzed by LC-UV and LC-ESI-MS methods and its identity could be suggested, without isolation or purification processes. Additionally, the degradation kinetic of both drugs and the cytotoxicity of the degraded samples were also studied. No evidence of cytotoxicity in human mononuclear cells was observed for drugs degraded samples. Furthermore, the present study also conducted the development and validation of a dissolution method for DEL and MAN combination tablets. The use of citrate buffer pH 3.2 as dissolution medium in combination with paddle at rotation of 75 rpm, resulted in an appropriate dissolution profile of both drugs, allowing the simultaneous quality control of DEL and MAN in combination tablets, as well as the ability to simulate the in vivo behavior of MAN from literature data. Then, the established procedures can be applied to improve the quality control of the products that will be marketed, as well as to contribute for assure the safety and therapeutic efficacy of the drugs.
|
775 |
Desenvolvimento e validação de metodologia analítica, ensaio de dissolução e estudo de estabilidade do carbonato de lodenafila / Development and validation of analytical methodology, dissolution test and stability study of lodenafil carbonateCodevilla, Cristiane Franco January 2012 (has links)
O carbonato de lodenafila é um inibidor da fosfodiesterase tipo 5, desenvolvido no Brasil, o qual é um dímero formado por duas moléculas de lodenafila ligadas por uma ponte carbonato. Encontra-se disponível sob a forma de comprimidos. Não existe monografia disponível para este fármaco em nenhum código oficial. Assim, o objetivo do presente estudo foi desenvolver métodos analíticos para análise qualitativa e quantitativa do carbonato de lodenafila em comprimidos, avaliação da estabilidade frente à degradação forçada, contemplando a cinética de fotodegradação, identificação e estudo de citotoxicidade in vitro dos produtos de degradação majoritários e desenvolvimento do teste de dissolução baseado em dados in vivo. A caracterização da substância química de referência foi realizada através da faixa de fusão por calorimetria exploratória diferencial, métodos espectrofotométricos na região do infravermelho (IV) e do ultravioleta (UV), assim como espectroscopia de ressonância magnética nuclear de 1H e 13C. Os métodos por cromatografia em camada delgada (CCD), espectrofotometria no UV, cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para identificar o fármaco na forma farmacêutica. Os seguintes métodos de análise quantitativa do fármaco em comprimidos foram desenvolvidos e validados: método indicativo da estabilidade por CLAE, espectrofotometria na região do UV e EC. Todos cumpriram com os parâmetros descritos pelas guias de validação e não apresentaram diferença significativa na determinação do fármaco. A cinética de fotodegradação do carbonato de lodenafila apresentou cinética de primeira ordem. Dois produtos majoritários encontrados na fotodegradação foram identificados por cromatografia líquida de ultra eficiência acoplada à espectrometria de massas (CLUE-MS/MS) como ácido 4-etoxi-3-(1-metil-7-oxo-3-propil-6,7-diidro- 1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfônico e ácido 4-etoxi-3-(1-metil-7-oxo- 3-propil-6,7-diidro-1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfínico. A avaliação da citotoxicidade in vitro indicou que a amostra de carbonato de lodenafila degradada não apresentou toxicidade. O teste de dissolução foi desenvolvido e validado utilizando como meio de dissolução 900 mL de HCl 0,1 M + lauril sulfato de sódio 1,5% (p/v), a 37 ± 0,5°C, pás a 25 rpm e quantificação por espectrofotometria no UV. O perfil de dissolução apresentou cinética de primeira ordem. De acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados no controle de qualidade do carbonato de lodenafila. / Lodenafil carbonate is a PDE5 inhibitor developed in Brazil, which is a dimer formed by two lodenafil molecules linked by a carbonate bridge. It is currently available in tablets. There is no monograph available for this drug in any official code. Thus, the purpose of the present study was the development of analytical methods for qualitative and quantitative analysis of LC in tablets, evaluation of drug stability in forced degradation, comprising the determination of photodegradation kinetic, identification and in vitro cytotoxicity study of two major degradation products and develop a dissolution test based on in vivo data. The characterization of the reference chemical substance was performed by: melting range by differencial scanning calorimetry, infrared (IR) and ultraviolet (UV) spectrophotometry methods, as well as the 1H and 13C nuclear magnetic resonance spectroscopy. The methods by thin-layer chromatography (TLC), UV spectrophotometry, high-performance liquid chromatography (LC) and capillary electrophoresis (CE) were used to identify the drug in pharmaceutical formulations. The following methods, applied to the assay of the drug in tablets were developed and validated: a stability-indicating HPLC method, UV spectrophotometry and CE. All of them met the criteria described by the validation guidelines and showed no significant statistically difference in the drug determination. The photodegradation kinetics of lodenafil carbonate showed firstorder kinetics. Two degradation products found by photodegradation were identified by ultra performance liquid chromatography-tandem mass spectrometry (UPLCMS/ MS) as 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7-dihydro-1H-pyrazolo [4,3- d]pyrimidin-5-yl)-benzenesulfonic acid and 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7- dihydro-1H-pyrazolo [4,3-d]pyrimidin-5-yl) benzenesulfinic acid. The in vitro cytotoxicity evaluation indicated that the lodenafil carbonate degraded sample did not show toxicity. A dissolution test was developed and validated using 900 mL of 0.1 M HCl + 1.5% sodium lauryl sulfate (w/v), at 37 ± 0.5 °C as dissolution medium, paddle at 25 rpm and quantitation by UV spectrophotometry. The dissolution profile showed first order kinetics. According to the obtained results, all proposed methods can be used in the quality control of lodenafil carbonate.
|
776 |
Validação de metodologia analítica, ensaio de dissolução e estudo de estabilidade do anti-retroviral fosamprenavir / Validation of analytical methodology, dissolution test and stability study of FosamprenavirRossi, Rochele Cassanta January 2011 (has links)
Fosamprenavir cálcico é o estér de fosfato do inibidor de protease amprenavir, aprovado pelo FDA em 2003. Considerando que não existe monografia disponível para este fármaco em nenhum código oficial, o objetivo deste trabalho foi desenvolver métodos analíticos para o controle de qualidade do fosamprenavir em comprimidos. Após a extração e purificação do fármaco, a partir dos comprimidos, o mesmo foi caracterizado utilizando espectroscopia de ressonância magnética nuclear de 1H, 13C e 31P e espectroscopia na região do infravermelho. Métodos por cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para a análise qualitativa do fármaco no produto acabado. A determinação quantitativa foi realizada através do desenvolvimento e validação dos métodos por UV, CLAE e EC. Os métodos quantitativos e qualitativos descritos neste trabalho demonstraram ser adequados para a determinação do fosamprenavir nos comprimidos O ensaio de dissolução foi desenvolvido baseado em dados in vivo. Para esta formulação a melhor condição obtida foi: cestos a 75 rpm e 900 ml de HCl 0,01 M. Utilizando essas condições, uma correlação nível A foi estabelecida (R2= 0,984). A cinética de dissolução foi determinada utilizando métodos modelos-dependentes sendo o modelo de liberação proposto por Hixson-Crowell o mais adequado. O ensaio de dissolução foi validado e pode ser aplicado para avaliar o perfil de dissolução dos comprimidos contendo fosamprenavir. O estudo preliminar de estabilidade para os comprimidos contendo fosamprenavir frente a degradação ácida, alcalina, oxidativa, térmica e fotolítica mostrou a luz como o fator importante de degradação com uma cinética de primeira ordem. / Fosamprenavir calcium is the phosphate ester prodrug of the human immunodeficiency virus (HIV) protease inhibitor amprenavir. Fosamprenavir was first approved by the Food and Drug Administration (FDA) in 2003. There is no monograph available for this drug in any official code. Thus, the objective of this study was to validate analytical methods for quality control of fosamprenavir tablets. Due to the lack of fosamprenavir reference standard, it was necessary to extract the drug from the tablets. Characterization was carried out by 1H, 13C-ATP and 31P nuclear magnetic resonance (NMR) and infrared spectroscopy (IR). Methods using thin-layer chromatography, ultraviolet spectroscopy, high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were performed for qualitative analysis. The quantitative determination was carried out through the development and validation of ultraviolet spectroscopy, HPLC and CE methods. The quantitative and qualitative methods described in this study demonstrated to be adequate to the determination of fosamprenavir in tablets. The dissolution test was developed based on in vivo data The dissolution conditions selected provided a significant linear relationship between fraction of drug absorbed versus fraction of drugs dissolved (R2= 0.984) and a level A IVIVC was established. The discriminatory power of the dissolution method was challenged. The kinetics of dissolution was determined using model-dependent methods. The dissolution profiles were better described by Hixson-Crowell model. The dissolution test was validated and can be used to evaluate the dissolution profile of fosamprenavir tablets. Forced degradation of fosamprenavir tablets after acid, alkaline, oxidative, thermal, photolytic conditions showed that light is the major concern. The photodegradation kinetics was determined, indicating a first order process.
|
777 |
Desenvolvimento tecnológico de grânulos esferoidais a partir de extrato seco de folhas e ramos de ilex paraguariensis St. Hil. aquifoliaceae (erva-mate) / Technological development of pellets obtained from aqueous extract of leaves and branches of Ilex paraguariensis St. Hil. aquifoliaceae (yerba mate)Yatsu, Francini Kiyono Jorge January 2010 (has links)
O presente trabalho teve como objetivos produzir um extrato seco de Ilex paraguariensis por spray-drying, em escala semi-industrial, e desenvolver grânulos esferoidais a partir do extrato seco, pelo método de extrusão/esferonização, bem como caracterizar as propriedades físicas, químicas e tecnológicas e investigar a estabilidade dos principais constituintes polifenólicos de ambos produtos frente à radiação UVC e ao calor. O extrato seco apresentou partículas esféricas (tamanho médio de 19,6 μm), com superfície lisa, boas propriedades de fluxo e rendimento satisfatório (67 %). No teste de fotoestabilidade, o extrato seco se manteve estável frente à radiação UVC, por 48 h, nos diferentes materiais de acondicionamento (frascos de vidro âmbar, frascos de vidro transparente ou vidros de relógio). No teste de estabilidade acelerada (40 ºC, 75 % de umidade relativa, 4 meses), o extrato seco demonstrou ser higroscópico e sensível ao calor, especialmente quando acondicionado em frascos de polietileno, por serem permeáveis à umidade. Os grânulos esferoidais, por sua vez, apresentaram tamanho médio de 1,10 mm, forma e rendimento (78,7 %) satisfatórios, boa dissolução em água (89,44 a 100,05 %) e adequada recuperação (> 95 %) do conteúdo de polifenóis totais em relação ao extrato seco. Os grânulos esferoidais foram estáveis frente à radiação UVC quando acondicionados em frascos de vidro âmbar, entretanto, o teor de polifenóis totais foi reduzido quando as amostras foram acondicionadas em vidro de relógio ou em frascos de vidro transparente. No teste de estabilidade acelerada, os grânulos esferoidais demonstraram ser higroscópicos e sensíveis ao calor. Este efeito foi mais pronunciado quando as amostras foram acondicionadas em frascos permeáveis (de polietileno) do que em frascos impermeáveis (de vidro transparente). Os resultados apontam para a importância da redução da umidade residual tanto do extrato seco quanto dos grânulos esferoidais, bem como para a necessidade de acondicioná-los em embalagens com proteção contra a umidade e a luz, sob baixas temperaturas. / The present work was designed to produce a dry extract of Ilex paraguariensis by the spray-drying process, in semi-industrial scale, and to develop pellets from dry extract, by the extrusion/spheronization method, as well as to characterize the physical, chemical and technological properties and to investigate the stability of the main polyphenol constituents from both products against UVC radiation and heat. The dry extract presented spherical particles (mean size of 19.6 μm), with smooth surface, good flow properties and satisfactory yield (67 %). In the photo stability test, the dry extract remained stable against UVC radiation, for 48 h, in all packaging material (amber glass bottles, transparent glass bottles or open-dishes). In the accelerated stability testing (40 ºC, 75 % relative humidity, 4 months), the dry extract demonstrated to be hygroscopic and sensible to the heat, especially when conditioned in polyethylene ethyl bottles because they are permeable to the humidity. The pellets presented mean size of 1.10 mm, satisfactory shape and yield (78.7 %), good dissolution in water (89.44 to 100.05 %) and good recovery (> 95 %) of the total polyphenol content in comparison with dry extract, the pellets were stable against UVC radiation when conditioned in amber glass bottles, however, the total polyphenol content was reduced when the samples were conditioned in open-dishes or in transparent glass bottles. In the accelerated stability testing, the pellets demonstrated to be hygroscopic and sensible to the heat. This effect was more pronounced when the samples were conditioned in permeable flasks (polyethylene ethyl bottles) than in semi-permeable flasks (transparent glass bottles). These findings point to the relevance of reducing the residual moisture of both dry extract and pellets, as well as to the necessity of conditioning both into opaque humidity tight packing, at low temperatures.
|
778 |
Mianserina : desenvolvimento e validação de métodos analíticos e estudo da estabilidadeSfair, Letícia Lenz January 2012 (has links)
O cloridrato de mianserina é um fármaco utilizado no tratamento da depressão e depressão associada a ansiedade. Seu efeito antidepressivo é atribuído, principalmente, ao bloqueio dos receptores 2-adrenérgicos pré-sinápticos e à atividade antagonista nos receptores de serotonina. A mianserina é classificada como um antidepressivo atípico, tendo como base o seu mecanismo de ação nãodefinido. A análise de fármacos é fundamental nas diversas fases do desenvolvimento farmacêutico e a literatura pesquisada apresenta poucos relatos de determinação quantitativa e estudos de estabilidade deste fármaco na forma farmacêutica comprimido revestido. Assim, objetivou-se o desenvolvimento e validação de métodos analíticos para determinação qualitativa e quantitativa por espectrofotometria na região do ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC). Inicialmente foi realizada a caracterização da substância química de referência (SQR) de cloridrato de mianserina por espectroscopia de absorção na região do infravermelho (IV), análise térmica por calorimetria exploratória de varredura (DSC), determinação da faixa de fusão, espectrometria de massas e ressonância magnética nuclear. Além disso, o trabalho apresenta o ensaio de dissolução e o estudo da estabilidade do fármaco nos comprimidos revestidos com isolamento e identificação do produto de degradação majoritário obtido em condições oxidativas. A identificação do produto de degradação majoritário foi realizada por cromatografia líquida de ultraperformance (UPLC) acoplado à espectrometria de massas (EM). / Mianserin hydrochloride is a drug for the treatment of depressive illness and depression associated with anxiety. Its antidepressant effect is mainly attributed to presynaptic alfa-2-adrenoreceptor blocking activity and serotonin receptors antagonism. Mianserin is classified as an atypical antidepressant, based on its mechanism of action not defined. The drug analysis is necessary in all steps of the pharmaceutical development and the literature has few reports of quantitative determination and stability studies of this drug in pharmaceutical formulation. Thus, the objective was the development and validation of analytical methods for qualitative and quantitative determination by UV spectrophotometry, liquid chromatography (LC) and capillary electrophoresis (CE). Initially was performed the characterization of mianserin reference standard by infrared spectroscopy (IV), thermal analysis by differential scanning calorimetry (DSC), determination of melting range, by mass spectrometry (MS) and by nuclear magnetic resonance techniques. Besides, it presents a dissolution test and stability study of the drug in coated tablets by the isolation and identification of the major degradation product from oxidative conditions. The identification of the major degradation product was performed by ultra high performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (MS).
|
779 |
Cloridrato de milnaciprana cápsulas : metodologia analítica, ensaio de dissolução e estudo de estabilidade / Milnacipran hydrochloride capsules: analytical methodology, dissolution test and study of stabilityDias, Carolina Lupi January 2011 (has links)
O cloridrato de milnaciprana (MNC) é um inibidor da recaptação da serotonina e noradrenalina (IRSN), produzido na forma farmacêutica cápsula, Ixel, Dalcipran e Toledomin, para o tratamento da depressão, e como comprimido, sob o nome comercial Savella, indicado no manejo da fibromialgia. Levando-se em consideração que não existem métodos oficiais para o doseamento do MNC em produto acabado, faz-se necessário o desenvolvimento e validação de métodos para assegurar a qualidade da forma farmacêutica. Deste modo, o objetivo deste trabalho foi a validação de métodos analíticos para o controle de qualidade do MNC cápsulas e a realização de estudo da degradação forçada do fármaco. A identificação e caracterização do fármaco foram realizadas através da análise do ponto de fusão, DSC, rotação específica e IV. Para a quantificação foram validados, segundo normas da ICH, os métodos UV-D2, CLAE e EC. A análise estatística demonstrou equivalência entre os métodos UV-D2 e CLAE, assim como entre CLAE e EC, para doseamento do MNC cápsulas. O teste de dissolução foi desenvolvido e validado utilizando cestas (50 rpm) em HCl 0,01M como meio de dissolução. A porcentagem de fármaco dissolvido foi determinada por ambos os métodos, CLAE e UV-D2. Os parâmetros cinéticos (ED% e t80%) da dissolução foram determinados e o modelo de Hixson-Crowell é o que melhor descreve a cinética de dissolução das cápsulas. A influência das condições de armazenamento da formulação farmacêutica no perfil de dissolução também foi avaliada. No estudo de degradação forçada, o MNC foi submetido à radiação UV (254 nm) e à oxidação com peróxido de hidrogênio. A CLAE foi o método empregado na análise do teor e pureza das amostras submetidas às degradações. Os resultados demonstraram a sensibilidade do fármaco nas condições testadas, havendo redução significativa de seu teor e a formação de produtos de degradação. A fotodegradação do MNC demonstrou cinética de 1ª ordem para o fármaco no estado sólido e para a solução das cápsulas, enquanto para o fármaco em solução demonstrou cinética de ordem zero. / Milnacipran hydrochloride (MNC) is a serotonin and noradrenaline reuptake inhibitor (SNRI), produced as capsules, Ixel, Dalcipran and Toledomin, for the treatment of depression, and as tablets, under the trade name Savella, indicated in the management of fibromyalgia. Considering that there are no official methods for the determination of the MNC capsules, it is necessary to develop and validate methods to ensure the quality of pharmaceutical formulation. Thus, the objective of this study was the validation of analytical methods for quality control of the MNC capsules and the forced degradation studies of the drug. The identification and characterization of the drug were performed by analyzing the melting point, DSC, specific rotation and IR. For the quantification were validated a second-derivative UV spectrophotometric (UV-D2), HPLC and a CE methods, according to ICH guide. Statistical analysis showed that the methods UV-D2 / HPLC, and HPLC / CE were equivalent to assay MNC capsules. The dissolution test was developed and validated using baskets (50 rpm) in 0.01N HCl as dissolution medium. The percentage of dissolved drug was determined by both methods (HPLC and UV-D2). The kinetic parameters (dissolution efficiency% and t80%) of drug release were determined and the Hixson-Crowell model is which best describes the dissolution kinetics of the capsules. The influence of storage conditions of the pharmaceutical formulation in the dissolution rate was also evaluated. In forced degradation study, the MNC was subjected to UV (254nm) and oxidation with hydrogen peroxide. The HPLC method was employed to analyze the assay and purity of samples subjected to degradation. The results showed levels of the drug decreased significantly and the presence of its degradation products. The photodegradation of MNC showed first order kinetics of reaction to the drug at solid state and to capsules solution, but the drug solution presented zero order kinetics.
|
780 |
Entacapona : desenvolvimento e validação de métodos analíticos, método de dissolução e estudo preliminar de estabilidade / Entacapone : development and validation of analytical methods, dissolution method and preliminary study of stabilityPaim, Clésio Soldateli January 2007 (has links)
Entacapona, inibidor da catecol-o-metiltransferase, é utilizada como terapia adjuvante à associação de levodopa + carbidopa no tratamento da doença de Parkinson. No Brasil encontra-se disponível na forma de comprimidos revestidos com o nome comercial de Comtan®. O objetivo desse trabalho foi desenvolver e validar métodos analíticos para o controle de qualidade da entacapona em comprimidos revestidos e método de dissolução, bem como, estudos preliminares de estabilidade durante o desenvolvimento do método indicativo de estabilidade por cromatografia líquida de alta eficiência (CLAE) e na determinação da cinética de fotodegradação. Devido à falta da substância química de referência de entacapona, realizou-se a extração do fármaco a partir dos comprimidos e a caracterização qualitativa e quantitativa por calorimetria diferencial de varredura (DSC), espectrofotometria na região do infravermelho (IV), ressonância magnética nuclear (RMN) e volumetria em meio não-aquoso. Métodos utilizando cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV) e CLAE foram utilizados para análise qualitativa de entacapona. A validação dos métodos para determinação quantitativa (UV e CLAE) foi realizada de acordo os parâmetros das principais Guias Oficiais (BRASIL, 2003; ICH, 2005; USP 30, 2007). O método de dissolução foi desenvolvido e validado de acordo com a USP. Os métodos qualitativos e quantitativos descritos nesse trabalho demonstraram-se adequados para determinação de entacapona em comprimidos revestidos. Para o método de dissolução as seguintes condições foram selecionadas: solução tampão acetato pH 5,3 como meio, utilizando pás a 50 rpm. A cinética de fotodegradação em metanol, frente à luz UV indicou reação de segunda ordem. Análises por CLAE-EM/EM sugerem que o produto de fotodegradação formado seja o isômero geométrico de entacapona (Z-entacapona). / Entacapone, inhibitor of the catechol-O-methyltransferase, is used as adjunct with levodopa + carbidopa association in the treatment of Parkinson’s disease. In Brazil it is available in tablets coated with the commercial name of Comtan®. The aim of this work was to develop and validate analytical methods for the quality control of entacapona in coated tablets, as well as, preliminary studies of stability during the development of stability-indicating high-performance liquid chromatography (HPLC) method and determination of photodegradation kinetics. Due to the lack of entacapone reference standard, it was necessary to extract the drug by the tablets and the qualitative and quantitative characterization was carried out by differential scanning calorimetry (DSC), infrared spectroscopy (IR), nuclear magnetic resonance (NMR) and non-aqueous titration of weak acid. Methods using thin-layer chromatography (CCD), ultraviolet spectroscopy (UV) and HPLC were performed to entacapone qualitative analysis. The validation of the methods for quantitative determination (UV and CLAE) was accomplished of agreement the parameters of the main Official Guides (BRASIL, 2003; ICH, 2005; USP 30, 2007). The dissolution test was developed and validate in according by USP. The qualitative and quantitative methods described in this study demonstrated to be adequate to determination of entacapone in coated tablets. For dissolution test the following conditions were selected: buffer acetate pH 5,3 as medium, using paddles at 50 rpm. The photodegradation kinetics in methanol, front to UV light indicated the second-order reaction. LC-MS/MS method results suggest that the photodegration product was the geometric isomer of entacapone (Z-entacapone).
|
Page generated in 0.03 seconds