Spelling suggestions: "subject:"aaf"" "subject:"faf""
81 |
Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable waterMeca, Karen Soraia 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
|
82 |
Avaliação da influência da distribuição de tamanho de partículas e do binômio velocidade/tempo de detenção na zona de reação no desempenho da flotação com emprego de sonda ultra-sônica e de técnica de análise por imagem / Analysis of particles distribution size and the pair velocity/hydraulic residence time in the reaction zone performance of a flotation unit by using ultrasonic probe and image analysisMoruzzi, Rodrigo Braga 24 June 2005 (has links)
O desempenho de uma unidade de flotação por ar dissolvido (FAD) em escala piloto, tratando água destinada ao abastecimento contendo 50 uC e 05 uT, foi investigada sob o ponto de vista das partículas presentes (micro-bolhas e flocos) e da hidrodinâmica. A análise centrou-se na zona de reação da unidade de FAD onde foi desenvolvido o modelo matemático proposto por Reali (1991). A determinação das partículas foi realizada por método que emprega a análise de imagem. A condição hidrodinâmica foi avaliada por meio de ensaios de estímulo e resposta, combinada com a análise tridimensional do escoamento feita através de mapeamento utilizando equipamento que emprega ultra-som (sonda micro-ADV). Para a consecução do trabalho foram desenvolvidos dois métodos. Um para aquisição, tratamento e obtenção da distribuição de tamanho de micro-bolhas e flocos utilizando a análise de imagem digital em instalação com escoamento contínuo, sem a extração de amostras. Outro, envolvendo o desenvolvimento de programa (VelDigital3D) para tratamento dos dados da sonda utilizada. Inicialmente, foram realizados os ensaios de validação da utilização da sonda micro-ADV em água contendo micro-bolhas de ar e os ensaios de mapeamento da unidade utilizando a referida sonda conjugada ao programa VelDigital3D. Posteriormente, foram investigados alguns possíveis agentes na aglutinação das micro-bolhas após a despressurização tais como: i) as condições de mistura expressas em termos da taxa de aplicação superficial (TAS) e tempo de detenção na zona de reação (Tdz.r), ii) razão de recirculação (p), iii) a variação de pH e, iv) a dosagem de coagulante (\'AL POT.+3\'). Finalmente, a sensibilidade do modelo matemático proposto por Reali (1991) para a zona de reação de unidades de FAD convencional foi verificada com base nos parâmetros de projeto: tempo de detenção da zona de reação (Tdz.r) e taxa de aplicação superficial na zona de clarificação TASap. (downflow); e com base nos parâmetros operacionais: distribuição de tamanho de partículas (micro-bolhas e flocos) e razão de recirculação (p). As principais conclusões foram: i) a sonda micro-ADV pode ser utilizada para obtenção do perfil de velocidade em águas contendo micro-bolhas de ar, nas vazões investigadas; ii) o escoamento no interior da zona de reação apresentou um padrão bem definido de recirculação ao longo da altura, confirmando os resultados obtidos com os ensaios estímulo e resposta; iii) a variação do diâmetro médio das micro-bolhas foi muito pequena (de 20 a 30 \'mü\'m), embora tenha havido ressalvas e iv) o modelo proposto por Reali (1991) foi sensível aos parâmetros investigados e responde coerentemente com o desempenho da unidade piloto de FAD. / This work investigated the performance of a dissolved air flotation (DAF) pilot plant, used to treat drinking water containing 05 Tu and 50 Cu. The particles (micro-bubbles and flocs) and hydraulic characteristics were taken into account. The focus was given in the reaction zone as hypothesized by Reali\'s mathematic model (REALI, 1991). An image analyses was used to assess particles distribution sizes. The hydraulics of the DAF tank was assessed by using a pulse stimulus-response test combined with the three-dimensional flow analyses carried-out with equipment that applied ultra sound (microADV). Therefore, two methods were developed; one for the acquisition, treatment and also to obtain the micro-bubbles and flocs sizes distribution, without the need of extracting samples and another, involved the development of a software (VelDigital3D) in order to treat the microADV data. Initially, the application of the microADV in the DAF process was evaluated. After, the data collection was made and the result was treated by using the VelDigital3D software. Sequentially, the effects of some agents for micro-bubbles coalescence after the releasing point were investigated: i) mixture conditions in terms of hydraulic loading rate (HLR) and detention time (DT); ii) recirculation rate (p); iii) pH variation and, iv) coagulant dosage (\'AL POT.+3\'). Finally, the mathematic model behavior proposed by Reali (1991) was investigated by varying some parameters in the design, such as: detention time in the reaction zone (DTr.z) and hydraulic loading rate in the clarification zone HLRc.z (dowflow); and by varying some operational parameters, such as: particles sizes distribution (micro-bubbles and flocs) and recirculation rate (p). The main conclusions were: i) the microADV probe can be used to obtain the velocity flow profile in water containing micro-bubbles; ii) the flow within the reaction zone showed a well defined pattern of recirculation throughout the height of the unit, confirming the obtained results by using the stimulus-response tests; iii) the variation of micro-bubbles medium size was low (from 20 to 30 \'mü\'m) but some points regarding this aspect were discussed and, iv) the behavior of the mathematical model proposed by Reali (1991) showed a significant adjustment to the experimental data proving that it can be applied to analyzed design parameters.
|
83 |
[de] ICH SAGE DIR BESCHEID! DIE BRASILIANISCHE UND DIE DEUTSCHE KULTUR IN KONTAKT UND IHRE RELEVANZ FUR DIE LEHRE VON PORTUGIESISCH ALS FREMDSPRACHE: / [pt] QUALQUER COISA, EU TE AVISO! AS CULTURAS BRASILEIRA E ALEMÃ EM CONTATO, E SUA RELEVÂNCIA PARA O ENSINO DE PL2E: UMA PERSPECTIVA INTERCULTURAL DA PAQUERA A PARTIR DO OLHAR FEMININOCINTIA REGINA DA COSTA 14 February 2019 (has links)
[pt] O presente trabalho se insere no campo do Português como Segunda Língua para Estrangeiros (PL2E) e do Alemão para Estrangeiros (ALE). Baseando-se nas teorias do Interculturalismo, identifica e compara aspectos culturais e linguísticos presentes em momentos de paquera e aproximação com vistas a um relacionamento amoroso, entre mulheres brasileiras e homens alemães e entre mulheres alemãs e homens brasileiros, a partir de categorias propostas por Geert Hofstede (Indulgência versus Restrição, Masculinidade/Feminilidade) e Alexander Thomas (Facilidade e prazer em fazer contatos e se comunicar e Emocionalismo, atribuídos ao Brasil; e Distância interpessoal diferenciadora e Orientação por regras, atribuídas à Alemanha). Demonstramos que, de forma geral, as propostas de Hofstede e Thomas
se confirmam nos dados analisados; no entanto, constatamos que os resultados da pesquisa de Hofstede em relação à categoria Masculinidade/Feminilidade aplicados ao Brasil e à Alemanha não se confirmam plenamente na análise dos nossos dados. Os objetivos específicos deste estudo são: (i) buscar uma compreensão mais ampla sobre relacionamentos interculturais, observando se as possíveis diferenças entre os aspectos culturais e linguísticos podem causar estranhamento e mal-entendidos; (ii) identificar se a consciência dessas diferenças, por parte dos indivíduos envolvidos, é prévia ao seu primeiro contato; e (iii) verificar se o confronto entre essas diferenças influencia no sucesso da relação. Esclarecem-se, assim, aspectos relativos aos relacionamentos interculturais e também a importância da abordagem desta temática em sala de aula, fornecendo aos profissionais envolvidos em ensino de PL2E e de ALE mais subsídios e embasamento teórico para o desenvolvimento das competências comunicativa e intercultural dos aprendizes. / [de] Die vorliegende Arbeit verbindet die Bereiche Portugiesisch als Fremdsprache (PL2E) und DaF. Sie basiert auf interkulturellen Theorien, identifiziert bzw. vergleicht kulturelle und sprachliche Aspekte, die im Moment des Flirts zwischen Brasilianerinnen und Deutschen und zwischen deutschen Frauen und Brasilianern auftauchen. Die Kulturdimensionen von Geert Hofstede (Genuss versus Beschrankung, Maskulinität/Feminilitat) und Alexander Thomas (Kontakt- und Kommunikationsfreudigkeit und Emotionalismus werden Brasilien und Interpersonale Distanzdifferenzierung und Regelorientierung Deutschland zugewiesen) wurden weitgehend bestätigt. In Bezug auf die Kategorie Maskulinität/Feminilitat wurden Hofstedes Ergebnisse allerdings nicht in der Analyse unserer Daten festgestellt. Die spezifischen Ziele dieser Studie sind: (i) ein tieferes Verstandnis der interkulturellen Beziehungen zu erhalten, unter Hinweis darauf, dass die moglichen Unterschiede zwischen den kulturellen und sprachlichen Aspekten zu Verfremdung und Missverstandnissen fuhren konnen; (ii) herauszufinden, ob das Bewusstsein fur diese Unterschiede vor dem ersten Kontakt zwischen den beteiligten Personen aufgetreten war; (iii) zu uberprufen, ob die Konfrontation zwischen diesen Unterschieden den Erfolg der Beziehung beeinflusst. Auf diese Weise werden nicht nur Aspekte der interkulturellen Beziehungen aufgeklart, sondern auch die Bedeutung der Behandlung dieses Themas im Unterricht thematisiert, damit Fachleute im Bereich Portugiesisch als Fremdsprache und DaF eine fundierte Grundlage für die Entwicklung der kommunikativen
Fahigkeiten so wie das interkulturellen Lernens erhalten.
|
84 |
Remoção de ferro, manganês e substâncias húmicas de água para abastecimento, com uso de flotação por ar dissolvido de alta taxa e oxidação química / Removal of iron, manganese and humic substances from source water by means of high-rate dissolved air flotation and chemical oxidationPatrizzi, Leila Jorge 05 December 2002 (has links)
O presente trabalho teve como objetivos estudar a potencialidade da FAD associada à oxidação química e comparar com a sedimentação também conjugada à oxidação química, em escala de laboratório, além de avaliar a eficiência de uma unidade piloto de FAD lamelar de alta taxa com escoamento horizontal no tratamento de água contendo ferro, manganês e matéria orgânica em concentrações acima dos padrões de potabilidade. Nos ensaios de flotação em escala de laboratório, entre os valores de dosagem de coagulante (cloreto férrico) investigados (na faixa de 15 a 35 mg/L) - o valor de 30 mg/L associado ao pH em torno de 6,2 e à aplicação de 2,7 mg/L de cloro, na forma de hipoclorito de sódio - apresentou os melhores resultados de remoção de cor, turbidez, ferro e manganês. No caso da sedimentação, também em escala de laboratório, dentre os valores de dosagem de coagulante investigados (30 e 45 mg/L), foi o valor de 30 mg/L associado a valor de pH em torno de 8,5 e à aplicação de 2,7 mg/L de cloro, que forneceu os melhores resultados de remoção de turbidez, ferro e manganês. A comparação entre a clarificação por FAD e por sedimentação da água de estudo, consideradas as melhores condições de coagulação e de floculação, mostrou que a flotação apresentou resultados de remoção de turbidez, cor aparente e ferro muito superiores aos obtidos nos ensaios de sedimentação. A unidade piloto de FAD lamelar de alta taxa com escoamento horizontal apresentou elevada eficiência de clarificação da água de estudo após prévia adequação das condições de oxidação química, coagulação e floculação, em escala de laboratório. Essa unidade foi capaz de operar, com excelente desempenho, com taxas de até 39 m/h, desde que fossem fornecidos 4,3 g de ar/m3 de água e tempo de floculação de 20 minutos. Finalmente, após o estudo e adequação das condições de coagulação, floculação e flotação por ar dissolvido, ) o efluente do flotador foi filtrado em unidade de filtração rápida descendente com leito de areia tendo apresentado residuais de turbidez em torno de 0,40 uT, cor aparente menor que 2 uC, ferro em torno de 0,10 mg/L e manganês a 0,02 mg/L, tanto para o efluente com taxa de flotação de 13 m/h quanto para 39 m/h, após 4 horas de filtração. Isto confirma a utilização, com elevada eficiência, da unidade piloto lamelar de alta taxa e escoamento horizontal com taxas de até 39 m/h, como pré-clarificação da água de estudo. / The aim of this research was to study and compare the potentiality of DAF and sedimentation processes associated with chemical oxidation, using lab scale (batch) as well as to assess the efficiency of a high-rate dissolved air flotation piloto unit with horizontal flow followed by a rapid sand bed filtration system, in the treatment of water with high concentration of iron, manganese and humic substances. For the essays in lab scale, among the values of coagulant dosage investigated (ferric chloride, in the range of 15-35 mg/L), the dosage of 30 mg/L associated to a pH value around 6.2 and oxidant dosage 2.7 mg/L of chlorine, in the form of sodium hypochlorite, presented the best results, in terms of color, turbidity, iron and manganese removal. For the sedimentation essays, also performed in lab scale, among the values of coagulant dosage investigated (30-45 mg/L), the dosage of 30 mg/L associated to 2.7 mg/L of chlorine supplied the best removal results for turbidity, iron and manganese. The comparison between dissolved air flotation and sedimentation clarification in lab scale, when the best conditions of coagulation and flocculation were carried out to both processes, showed that the results for flotation were highly better than the results obtained by sedimentation, in terms of turbidity, color and iron removal. The high-rate DAF pilot unit with horizontal flow showed high clarification efficiency after previous adaptation of the conditions of chemical oxidation, coagulation and flocculation, as investigated at the lab essays. The unit operated with excellent performance using high rates up to 39 m/h, since it was supplied 4.3 g of air/m3 of water and flocculation time of 20 minutes. The sand bed unit of rapid filtration showed high performance in removal of turbidity (around 0.40 uT), color (< 2 uC), iron (around 0.10 mg/L) and manganese (0.02 mg/L), with 4 hours of filtration, when rates from 13 to 39 m/h were used in the high-rate DAF pilot unit. This fact confirms that the use of the high-rate DAF pilot unit with rates up to 39 m/h is feasible with high efficiency as a pre-clarification to the water evaluated.
|
85 |
Remoção de nutrientes do efluente de reator anaeróbio utilizando reatores microaeróbio e com aeração intermitente seguidos de flotação por ar dissolvido / Nutrient removal of anaerobic effluent reactor using microaerobic and intermittent aeration reactors followed by DAFMarchetto, Margarida 07 December 2001 (has links)
O principal objetivo deste trabalho consistiu em avaliar o desempenho de um sistema experimental para pós-tratamento de reatores anaeróbios. Foram testados reator microaerado e reator com aeração intermitente, seguidos de flotação por ar dissolvido. Foram avaliadas condições para se obter nitrificação, desnitrificação e remoção de fósforo, em reator com baixa concentração de OD e em reator em que se alternaram fases aeróbia e anaeróbia. O trabalho foi desenvolvido em duas etapas distintas: a Etapa I constituiu de ensaios preliminares, utilizando instalação em escala de laboratório, alimentados com efluente de reator anaeróbio compartimentado, composta de sistema de aeração com quatro reatores em paralelo, com capacidade de 11,5 L cada, operando em regime hidráulico contínuo, com concentrações de OD na faixa de 0,2 a 0,9 mg/L, em temperatura controlada de 30±2°C. Na Etapa I também foram operados reatores com aeração intermitente. Na Etapa II, empregou-se instalação para tratamento aeróbio, com capacidade de 100 L, seguida de flotador, em temperatura ambiente de 25±6°C, sendo operado um reator microaerado e outro com aeração intermitente; ambos foram alimentados com efluente de um reator anaeróbio de leito expandido. O sistema com aeração intermitente (θh: 6 h) mostrou-se estável, apresentando elevada remoção média de DQO (92%), de P-PO4-3 (90%) e de nitrogênio (sem utilização de fonte externa de carbono; apenas com recirculação adequada do lodo). Para θh médio de 8 h, nos ensaios com ciclos alternados de 2 h, com aeração e 4 h, sem aeração, foi obtida remoção máxima de P-PO4-3, de 95% para as amostras brutas e 97% para as amostras filtradas, com remoção média de 84%, e 88%, respectivamente. Considerando apenas os valores médios, registrou-se ligeira queda de remoção de P-PO4-3, e de DQO em relação ao período com θh médio de 6 h. Os resultados com aeração intermitente foram sensivelmente melhores em relação aos obtidos com microaeração. / The aim of this research the performance evaluation of a pilot system for post treatment of anaerobic reactors. Microaeration and intermittent aeration reactors, followed by dissolved air flotation (DAF) were examined. It was assessed the conditions to obtain nitrification, denitrification and phosphorus removal, in reactor operated with low concentration of OD and in a reactor operated were alternated aerobic and anaerobic phases were used. The research was developed in two different stages. The first one, constituted of preliminary test, using installation in laboratory scale, fed with effiuent of compartment anaerobic reactor. This system was composed of aeration system with four reactors in parallel, with 11,5 L each, operating in continuous flow, with concentrations of DO between 0.2 to 0.9 mg/L, in controlled temperature of 30±2 ºC. The reactors were also operated with intermittent aeration. In the second stage, an installation with 100L was used for aerobic treatment, followed by DAF, in room temperature of 25±6°C. One reactor was operated under microaeration and another with intermittent aeration. Both were fed with effiuent of an expanded bed anaerobic reactor. The system with intermittent aeration (θh: 6 h) shown stable, presenting high COD removal of (92%) and phosphorus removal (90%), without use of external carbon source; just with adapted recirculation of the sludge. For an average hydraulic retention time of 8 h, in the test with alternate cycles of 2 h with aeration and 4 h without aeration, it was obtained a maximum removal of P-PO4-3 equal 95% for the raw samples and 97% for the filtered samples, with average removal of 84%, and 88%, respectively. The results with intermittent aeration were significantely better in relation to the obtained with microaeration.
|
86 |
Wolfgang Herrndorf: Čik. Didaktická adaptace románu a filmové adaptace. / Wolfgang Herrndorf: Didactic adaptation of novel and film.Lang, Marek January 2019 (has links)
This master's dissertation deals with the elaboration of a didactic adaptation of the novel Tschick by Wolfgang Herrndorf and its film adaptation. The goal of this master's dissertation is to create a complete educational project that is used in a real school curriculum. In the theoretical part, the basic principles for creating such a project are expounded: The terms literature and film in teaching German are explained. Moreover, there are reasons listed why literature and films ought to be a firm part of second language teaching. The literary work Tschick by Wolfgang Herrndorf is dealt with in the perspective of literary studies. Furthermore, the theoretical and methodological principles are introduced in the purpose of creating such a project. This is implemented in the practical part of this master's dissertation using the novel Tschick by Wolfgang Herrndorf and its film adaptation as a foundation of this project. Thus, the lesson materials and plans are created that are used at a real school, Gymnázium, Praha 6, Arabská 14, where a group of 17 students, who are at level A2, is chosen for this project. The author of this thesis works at this school. As the school is technically well equipped, various information technologies are utilized within the project. The entire course of the...
|
87 |
Remoção de nutrientes do efluente de reator anaeróbio utilizando reatores microaeróbio e com aeração intermitente seguidos de flotação por ar dissolvido / Nutrient removal of anaerobic effluent reactor using microaerobic and intermittent aeration reactors followed by DAFMargarida Marchetto 07 December 2001 (has links)
O principal objetivo deste trabalho consistiu em avaliar o desempenho de um sistema experimental para pós-tratamento de reatores anaeróbios. Foram testados reator microaerado e reator com aeração intermitente, seguidos de flotação por ar dissolvido. Foram avaliadas condições para se obter nitrificação, desnitrificação e remoção de fósforo, em reator com baixa concentração de OD e em reator em que se alternaram fases aeróbia e anaeróbia. O trabalho foi desenvolvido em duas etapas distintas: a Etapa I constituiu de ensaios preliminares, utilizando instalação em escala de laboratório, alimentados com efluente de reator anaeróbio compartimentado, composta de sistema de aeração com quatro reatores em paralelo, com capacidade de 11,5 L cada, operando em regime hidráulico contínuo, com concentrações de OD na faixa de 0,2 a 0,9 mg/L, em temperatura controlada de 30±2°C. Na Etapa I também foram operados reatores com aeração intermitente. Na Etapa II, empregou-se instalação para tratamento aeróbio, com capacidade de 100 L, seguida de flotador, em temperatura ambiente de 25±6°C, sendo operado um reator microaerado e outro com aeração intermitente; ambos foram alimentados com efluente de um reator anaeróbio de leito expandido. O sistema com aeração intermitente (θh: 6 h) mostrou-se estável, apresentando elevada remoção média de DQO (92%), de P-PO4-3 (90%) e de nitrogênio (sem utilização de fonte externa de carbono; apenas com recirculação adequada do lodo). Para θh médio de 8 h, nos ensaios com ciclos alternados de 2 h, com aeração e 4 h, sem aeração, foi obtida remoção máxima de P-PO4-3, de 95% para as amostras brutas e 97% para as amostras filtradas, com remoção média de 84%, e 88%, respectivamente. Considerando apenas os valores médios, registrou-se ligeira queda de remoção de P-PO4-3, e de DQO em relação ao período com θh médio de 6 h. Os resultados com aeração intermitente foram sensivelmente melhores em relação aos obtidos com microaeração. / The aim of this research the performance evaluation of a pilot system for post treatment of anaerobic reactors. Microaeration and intermittent aeration reactors, followed by dissolved air flotation (DAF) were examined. It was assessed the conditions to obtain nitrification, denitrification and phosphorus removal, in reactor operated with low concentration of OD and in a reactor operated were alternated aerobic and anaerobic phases were used. The research was developed in two different stages. The first one, constituted of preliminary test, using installation in laboratory scale, fed with effiuent of compartment anaerobic reactor. This system was composed of aeration system with four reactors in parallel, with 11,5 L each, operating in continuous flow, with concentrations of DO between 0.2 to 0.9 mg/L, in controlled temperature of 30±2 ºC. The reactors were also operated with intermittent aeration. In the second stage, an installation with 100L was used for aerobic treatment, followed by DAF, in room temperature of 25±6°C. One reactor was operated under microaeration and another with intermittent aeration. Both were fed with effiuent of an expanded bed anaerobic reactor. The system with intermittent aeration (θh: 6 h) shown stable, presenting high COD removal of (92%) and phosphorus removal (90%), without use of external carbon source; just with adapted recirculation of the sludge. For an average hydraulic retention time of 8 h, in the test with alternate cycles of 2 h with aeration and 4 h without aeration, it was obtained a maximum removal of P-PO4-3 equal 95% for the raw samples and 97% for the filtered samples, with average removal of 84%, and 88%, respectively. The results with intermittent aeration were significantely better in relation to the obtained with microaeration.
|
88 |
Avaliação da influência da distribuição de tamanho de partículas e do binômio velocidade/tempo de detenção na zona de reação no desempenho da flotação com emprego de sonda ultra-sônica e de técnica de análise por imagem / Analysis of particles distribution size and the pair velocity/hydraulic residence time in the reaction zone performance of a flotation unit by using ultrasonic probe and image analysisRodrigo Braga Moruzzi 24 June 2005 (has links)
O desempenho de uma unidade de flotação por ar dissolvido (FAD) em escala piloto, tratando água destinada ao abastecimento contendo 50 uC e 05 uT, foi investigada sob o ponto de vista das partículas presentes (micro-bolhas e flocos) e da hidrodinâmica. A análise centrou-se na zona de reação da unidade de FAD onde foi desenvolvido o modelo matemático proposto por Reali (1991). A determinação das partículas foi realizada por método que emprega a análise de imagem. A condição hidrodinâmica foi avaliada por meio de ensaios de estímulo e resposta, combinada com a análise tridimensional do escoamento feita através de mapeamento utilizando equipamento que emprega ultra-som (sonda micro-ADV). Para a consecução do trabalho foram desenvolvidos dois métodos. Um para aquisição, tratamento e obtenção da distribuição de tamanho de micro-bolhas e flocos utilizando a análise de imagem digital em instalação com escoamento contínuo, sem a extração de amostras. Outro, envolvendo o desenvolvimento de programa (VelDigital3D) para tratamento dos dados da sonda utilizada. Inicialmente, foram realizados os ensaios de validação da utilização da sonda micro-ADV em água contendo micro-bolhas de ar e os ensaios de mapeamento da unidade utilizando a referida sonda conjugada ao programa VelDigital3D. Posteriormente, foram investigados alguns possíveis agentes na aglutinação das micro-bolhas após a despressurização tais como: i) as condições de mistura expressas em termos da taxa de aplicação superficial (TAS) e tempo de detenção na zona de reação (Tdz.r), ii) razão de recirculação (p), iii) a variação de pH e, iv) a dosagem de coagulante (\'AL POT.+3\'). Finalmente, a sensibilidade do modelo matemático proposto por Reali (1991) para a zona de reação de unidades de FAD convencional foi verificada com base nos parâmetros de projeto: tempo de detenção da zona de reação (Tdz.r) e taxa de aplicação superficial na zona de clarificação TASap. (downflow); e com base nos parâmetros operacionais: distribuição de tamanho de partículas (micro-bolhas e flocos) e razão de recirculação (p). As principais conclusões foram: i) a sonda micro-ADV pode ser utilizada para obtenção do perfil de velocidade em águas contendo micro-bolhas de ar, nas vazões investigadas; ii) o escoamento no interior da zona de reação apresentou um padrão bem definido de recirculação ao longo da altura, confirmando os resultados obtidos com os ensaios estímulo e resposta; iii) a variação do diâmetro médio das micro-bolhas foi muito pequena (de 20 a 30 \'mü\'m), embora tenha havido ressalvas e iv) o modelo proposto por Reali (1991) foi sensível aos parâmetros investigados e responde coerentemente com o desempenho da unidade piloto de FAD. / This work investigated the performance of a dissolved air flotation (DAF) pilot plant, used to treat drinking water containing 05 Tu and 50 Cu. The particles (micro-bubbles and flocs) and hydraulic characteristics were taken into account. The focus was given in the reaction zone as hypothesized by Reali\'s mathematic model (REALI, 1991). An image analyses was used to assess particles distribution sizes. The hydraulics of the DAF tank was assessed by using a pulse stimulus-response test combined with the three-dimensional flow analyses carried-out with equipment that applied ultra sound (microADV). Therefore, two methods were developed; one for the acquisition, treatment and also to obtain the micro-bubbles and flocs sizes distribution, without the need of extracting samples and another, involved the development of a software (VelDigital3D) in order to treat the microADV data. Initially, the application of the microADV in the DAF process was evaluated. After, the data collection was made and the result was treated by using the VelDigital3D software. Sequentially, the effects of some agents for micro-bubbles coalescence after the releasing point were investigated: i) mixture conditions in terms of hydraulic loading rate (HLR) and detention time (DT); ii) recirculation rate (p); iii) pH variation and, iv) coagulant dosage (\'AL POT.+3\'). Finally, the mathematic model behavior proposed by Reali (1991) was investigated by varying some parameters in the design, such as: detention time in the reaction zone (DTr.z) and hydraulic loading rate in the clarification zone HLRc.z (dowflow); and by varying some operational parameters, such as: particles sizes distribution (micro-bubbles and flocs) and recirculation rate (p). The main conclusions were: i) the microADV probe can be used to obtain the velocity flow profile in water containing micro-bubbles; ii) the flow within the reaction zone showed a well defined pattern of recirculation throughout the height of the unit, confirming the obtained results by using the stimulus-response tests; iii) the variation of micro-bubbles medium size was low (from 20 to 30 \'mü\'m) but some points regarding this aspect were discussed and, iv) the behavior of the mathematical model proposed by Reali (1991) showed a significant adjustment to the experimental data proving that it can be applied to analyzed design parameters.
|
89 |
Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable waterKaren Soraia Meca 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
|
90 |
Remoção de ferro, manganês e substâncias húmicas de água para abastecimento, com uso de flotação por ar dissolvido de alta taxa e oxidação química / Removal of iron, manganese and humic substances from source water by means of high-rate dissolved air flotation and chemical oxidationLeila Jorge Patrizzi 05 December 2002 (has links)
O presente trabalho teve como objetivos estudar a potencialidade da FAD associada à oxidação química e comparar com a sedimentação também conjugada à oxidação química, em escala de laboratório, além de avaliar a eficiência de uma unidade piloto de FAD lamelar de alta taxa com escoamento horizontal no tratamento de água contendo ferro, manganês e matéria orgânica em concentrações acima dos padrões de potabilidade. Nos ensaios de flotação em escala de laboratório, entre os valores de dosagem de coagulante (cloreto férrico) investigados (na faixa de 15 a 35 mg/L) - o valor de 30 mg/L associado ao pH em torno de 6,2 e à aplicação de 2,7 mg/L de cloro, na forma de hipoclorito de sódio - apresentou os melhores resultados de remoção de cor, turbidez, ferro e manganês. No caso da sedimentação, também em escala de laboratório, dentre os valores de dosagem de coagulante investigados (30 e 45 mg/L), foi o valor de 30 mg/L associado a valor de pH em torno de 8,5 e à aplicação de 2,7 mg/L de cloro, que forneceu os melhores resultados de remoção de turbidez, ferro e manganês. A comparação entre a clarificação por FAD e por sedimentação da água de estudo, consideradas as melhores condições de coagulação e de floculação, mostrou que a flotação apresentou resultados de remoção de turbidez, cor aparente e ferro muito superiores aos obtidos nos ensaios de sedimentação. A unidade piloto de FAD lamelar de alta taxa com escoamento horizontal apresentou elevada eficiência de clarificação da água de estudo após prévia adequação das condições de oxidação química, coagulação e floculação, em escala de laboratório. Essa unidade foi capaz de operar, com excelente desempenho, com taxas de até 39 m/h, desde que fossem fornecidos 4,3 g de ar/m3 de água e tempo de floculação de 20 minutos. Finalmente, após o estudo e adequação das condições de coagulação, floculação e flotação por ar dissolvido, ) o efluente do flotador foi filtrado em unidade de filtração rápida descendente com leito de areia tendo apresentado residuais de turbidez em torno de 0,40 uT, cor aparente menor que 2 uC, ferro em torno de 0,10 mg/L e manganês a 0,02 mg/L, tanto para o efluente com taxa de flotação de 13 m/h quanto para 39 m/h, após 4 horas de filtração. Isto confirma a utilização, com elevada eficiência, da unidade piloto lamelar de alta taxa e escoamento horizontal com taxas de até 39 m/h, como pré-clarificação da água de estudo. / The aim of this research was to study and compare the potentiality of DAF and sedimentation processes associated with chemical oxidation, using lab scale (batch) as well as to assess the efficiency of a high-rate dissolved air flotation piloto unit with horizontal flow followed by a rapid sand bed filtration system, in the treatment of water with high concentration of iron, manganese and humic substances. For the essays in lab scale, among the values of coagulant dosage investigated (ferric chloride, in the range of 15-35 mg/L), the dosage of 30 mg/L associated to a pH value around 6.2 and oxidant dosage 2.7 mg/L of chlorine, in the form of sodium hypochlorite, presented the best results, in terms of color, turbidity, iron and manganese removal. For the sedimentation essays, also performed in lab scale, among the values of coagulant dosage investigated (30-45 mg/L), the dosage of 30 mg/L associated to 2.7 mg/L of chlorine supplied the best removal results for turbidity, iron and manganese. The comparison between dissolved air flotation and sedimentation clarification in lab scale, when the best conditions of coagulation and flocculation were carried out to both processes, showed that the results for flotation were highly better than the results obtained by sedimentation, in terms of turbidity, color and iron removal. The high-rate DAF pilot unit with horizontal flow showed high clarification efficiency after previous adaptation of the conditions of chemical oxidation, coagulation and flocculation, as investigated at the lab essays. The unit operated with excellent performance using high rates up to 39 m/h, since it was supplied 4.3 g of air/m3 of water and flocculation time of 20 minutes. The sand bed unit of rapid filtration showed high performance in removal of turbidity (around 0.40 uT), color (< 2 uC), iron (around 0.10 mg/L) and manganese (0.02 mg/L), with 4 hours of filtration, when rates from 13 to 39 m/h were used in the high-rate DAF pilot unit. This fact confirms that the use of the high-rate DAF pilot unit with rates up to 39 m/h is feasible with high efficiency as a pre-clarification to the water evaluated.
|
Page generated in 0.0459 seconds