• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 12
  • 12
  • 12
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Denture base resin reinforced with highly drawn linear polyethylene fibres: dimensional changes and dentureconstruction technique

Cheng, Yi-yung., 鄭而容 January 1994 (has links)
published_or_final_version / Dentistry / Master / Master of Philosophy
2

Denture base resin reinforced with highly drawn linear polyethylene fibres dimensional changes and denture construction technique /

Cheng, Yi-yung. January 1994 (has links)
Thesis (M.Phil)--University of Hong Kong, 1994. / Includes bibliographical references. Also available in print.
3

Acrylic and acrylic-styrene resins their properties in relation to their uses as restorative materials in dentistry /

Mann, William Richard, January 1942 (has links)
Thesis (M.S.)--University of Michigan, 1942.
4

An in vitro investigation of the flexural strength and microstructure of "stick glass fiber" and "wire mesh" reinforced heat cured denture base acrylic

Kiilu, Paul Muli January 2008 (has links)
Submitted in fulfillment of the Degree of Master in Technology: Dental Technology in the Department of Dental Services Faculty of Health Sciences, Durban University of Technology, 2008. / Globally in the field of Dental Technology, polymethyl methacrylate (PMMA) resin continues to be the popular material for the fabrication of denture bases in removable prosthodontics. However, the mechanical strength of the denture base is a concern due to fractures occurring intra-orally or when accidentally dropped. The objective of this in vitro investigation was therefore to evaluate and compare the flexural strength and microstructure of stick® glass fibre and wire mesh reinforced PMMA resin after thermocycling. The selection of the materials used in this study was based primarily on their popularity and availability in South Africa. These materials were selected to ensure that the results of this study would have further implicational value in the commercial dental industry when published. This investigation was conducted by means of fabricating a total of 90 PMMA resin specimens and divided in three groups consisting of 30 specimens each. Sample groups 1 and 2 were reinforced with stick® glass fibres and wire mesh respectively. The un-reinforced sample group was the control. All 90 specimens were thermocycled in water at temperatures between 5˚C and 55˚C for 2100 cycles. The flexural strength of each specimen was tested using a universal testing machine and the microstructure of the fractured surfaces was then analysed using scanning electron microscopes (SEM). SPSS version 15.0 was used for data analysis. A p-value of <0.05 was considered as statistically significant. Data were analysed using parametric and non-parametric statistical methods. Statistically significant differences in flexural strength existed between the three sample groups (p<0.001) with the stick® glass fibre and wire mesh sample groups being significantly superior to the control. Furthermore there was a significant association between fracture modes and sample groups. Microscopic analysis revealed the presence of voids. Statistically, in terms of microstructure (% of voids present), a significant difference existed between all sample groups. With regards to surface texture of the compression and tension sides of the test specimens, significant differences existed between the three sample groups. Furthermore microscopic analysis revealed partial impregnation and distribution of the fibres to the PMMA resin matrix and un-bonding between the wire mesh and PMMA resin matrix. Statistically, the Mann-Whitney test was conducted to compare flexural strength between sample groups with and without voids. The flexural strength was higher in sample groups with voids than those without. This is an important finding from the clinical perspective because, in some structures of dentures, toughness is a desired property. Nevertheless in order to find the long-term data especially on clinical behaviour of these new fibre reinforcement systems, more studies should be conducted. / DUT Institutional Research Committee
5

An in vitro investigation of the flexural strength and microstructure of "stick glass fiber" and "wire mesh" reinforced heat cured denture base acrylic

Kiilu, Paul Muli January 2008 (has links)
Submitted in fulfillment of the Degree of Master in Technology: Dental Technology in the Department of Dental Services Faculty of Health Sciences, Durban University of Technology, 2008. / Globally in the field of Dental Technology, polymethyl methacrylate (PMMA) resin continues to be the popular material for the fabrication of denture bases in removable prosthodontics. However, the mechanical strength of the denture base is a concern due to fractures occurring intra-orally or when accidentally dropped. The objective of this in vitro investigation was therefore to evaluate and compare the flexural strength and microstructure of stick® glass fibre and wire mesh reinforced PMMA resin after thermocycling. The selection of the materials used in this study was based primarily on their popularity and availability in South Africa. These materials were selected to ensure that the results of this study would have further implicational value in the commercial dental industry when published. This investigation was conducted by means of fabricating a total of 90 PMMA resin specimens and divided in three groups consisting of 30 specimens each. Sample groups 1 and 2 were reinforced with stick® glass fibres and wire mesh respectively. The un-reinforced sample group was the control. All 90 specimens were thermocycled in water at temperatures between 5˚C and 55˚C for 2100 cycles. The flexural strength of each specimen was tested using a universal testing machine and the microstructure of the fractured surfaces was then analysed using scanning electron microscopes (SEM). SPSS version 15.0 was used for data analysis. A p-value of <0.05 was considered as statistically significant. Data were analysed using parametric and non-parametric statistical methods. Statistically significant differences in flexural strength existed between the three sample groups (p<0.001) with the stick® glass fibre and wire mesh sample groups being significantly superior to the control. Furthermore there was a significant association between fracture modes and sample groups. Microscopic analysis revealed the presence of voids. Statistically, in terms of microstructure (% of voids present), a significant difference existed between all sample groups. With regards to surface texture of the compression and tension sides of the test specimens, significant differences existed between the three sample groups. Furthermore microscopic analysis revealed partial impregnation and distribution of the fibres to the PMMA resin matrix and un-bonding between the wire mesh and PMMA resin matrix. Statistically, the Mann-Whitney test was conducted to compare flexural strength between sample groups with and without voids. The flexural strength was higher in sample groups with voids than those without. This is an important finding from the clinical perspective because, in some structures of dentures, toughness is a desired property. Nevertheless in order to find the long-term data especially on clinical behaviour of these new fibre reinforcement systems, more studies should be conducted.
6

Tests on color stability of acrylic resins used in operative dentistry a thesis submitted in partial fulfillment ... operative dentistry ... /

Moyer, Ralph Sayles. January 1943 (has links)
Thesis (M.S.)--University of Michigan, 1943.
7

The efficacy of Hibiscus sabdariffa as a fibre-reinforcement material for denture base acrylic resins

Okeke, Kenneth Nkemdilim January 2017 (has links)
Submitted in fulfillment of the requirements for the award of the degree of Master of Health Sciences: Dental Technology, Durban University of Technology, Durban, South Africa, 2017. / The poor mechanical properties of denture base acrylic resins can cause dentures to fracture either through impact or stress fatigue. Various metal reinforcing materials such as powders, nets, plates and wires together with synthetic fibres are therefore used to improve the strength properties of denture base acrylic resins. Despite their benefits, they are difficult to apply during fabrication, are costly, non-recyclable, and not environmentally friendly. The suitability of Hibiscus sabdariffa (H. sabdariffa) as a fibre reinforcement material for denture base acrylic resins was therefore investigated. A quantitative research paradigm and a two-phased experimental research design was used. The preliminary study used Fourier transform infrared (FT-IR) spectroscopy, thermogravimetric analysis (TGA) and field emission scanning electron microscope (FE-SEM) to assess the characteristics of, and the effect of, mercerisation on H. sabdariffa fibres. In determining the suitability of H. sabdariffa fibres, fibre diameter, fibre density, moisture content and absorption were examined. The main study investigated the mechanical and physical properties of two sample groups namely: the unreinforced (control) group and the H. sabdariffa fibre-reinforced (test) group denture base acrylic resins. The flexural strength, impact strength, specific wear rate, hardness and water absorption behaviour were determined in line with ASTM D 790 and D 256, G 99, D 2583 and D 570 methods of testing, respectively. Parametric and non-parametric tests were used to analyse the mean differences (p = 0.05) between the unreinforced and the H. sabdariffa fibre-reinforced denture base acrylic resins. The preliminary study revealed that H. sabdariffa fibres favourably compared to other lignocellulosic fibres in terms of fibre diameter, fibre density, water content and absorption behaviour. In the main study, a t-test revealed that there were significant differences in flexural strength at 0oC (p < 0.0001) and at 65oC (p < 0.0025) between the two sample groups. Similarly, there were significant differences in the impact strength between the two sample groups at 0oC (p < 0.031) and at 65oC (p < 0.0001). In contrast to the 200g load, there were significant differences (p < 0.044) in the specific wear rate of the unreinforced and the H. sabdariffa fibre-reinforced denture base acrylic resins at the 500g load. The hardness values revealed no significant differences (p > 0.707) between the two sample groups. There were however, significant differences (p < 0.041) in the water absorption rate between the two sample groups. Overall, the prominent features of this study showed that H. sabdariffa fibre is a suitable reinforcement fibre material for denture base acrylic resins and is in compliance with ISO 1567: 1999. Although this study found that H. sabdariffa fibres can be used as reinforcement material for denture base acrylic resins, the results cannot be generalised to clinical conditions, therefore in vitro and in vivo investigations are recommended. / M
8

Correlation between flexural strength and denture base acrylic thickness overlaying implant stud attachments

Alawadhi, Khaled N. January 2010 (has links)
Thesis (M.S.)--West Virginia University, 2010. / Title from document title page. Document formatted into pages; contains viii, 49 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 41-48).
9

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental /

Almeida, Carolina Souza. January 2015 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Lafayette Nogueira Júnior / Banca: Alfredo Mikail Melo Mesquita / Resumo: O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / Abstract: The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh / Mestre
10

Using eggshell for the development of a quality alternative material to pumice in reducing the surface roughness of heat-cured acrylic resins.

Onwubu, Stanley Chibuzor January 2016 (has links)
Submitted in fulfillment of requirements of the degree of Master in Health Sciences: Dental Technology, Durban University of Technology, Durban, South Africa, 2016. / Pumice is used in the polishing of dental appliances to remove surface irregularities. It is usually used in a slurry form that is pumice powder mixed with water. In Nigeria, the increased cost of pumice as a result of its limited supply into the country has encouraged dental technicians to re-use pumice slurry for longer periods than advocated when polishing acrylic dentures, whether new or old dentures which have been worn in the mouth. Consequently, this is likely to increase cross-infection of communicable diseases in the dental technology laboratory. Although materials such as white sand, black sand and porcelnite can be used, literature documents that these materials are less effective in the polishing of acrylic dentures (Areeg 2011). The focus of this study was to use eggshells, a natural waste product, to develop and test the quality of an alternative material to reduce the surface roughness of heat-cured acrylic resins. A quantitative research paradigm and an experimental research strategy were adopted. The research design included two phases. In phase one of this study, different characterisation techniques such as Brunnae-Emmer Teller (BET); Fourier Transform Infrared Spectroscopy (FTIR); X-ray Diffraction (XRD); Energy Dispersive X-ray Spectroscopy (EDX) and Scanning Electron Microscope (SEM); Transmission Electron Microscopy (TEM); Laser Scattering Particle Size Distribution Analyser (PSA); Thermo-Gravimetric Analysis (TGA); and Induction-Coupling-Optical Emission Spectroscopy (ICP-OES) were used to assess the suitability of the new abrasive material (NAM). In addition, the level of microbial contamination of the NAM was assessed in line with the specified microbial limits for cosmetic products. In contrast, phase two investigated the product-based quality of the NAM as an abrasive material for removable dental appliances. There were two sample groups, that is, the NAM (test group) and Pumice (control), and each sample group had 50 PMMA acrylic specimens. The surface roughness (Ra) was measured using a Talysurf profilometer. An Independent Tukey test was used to analyse the Ra values (p=0.05). A Scanning Electron Microscope (SEM) and Optical Microscope (OEM) were further used to support the results of the profilometer in terms of the quality of surface finish and polish. Validity of the study was achieved following the ISO 20795-1 (2013) methods of preparation and fabrication of the acrylic specimens. The reliability was determined via reproducibility and repeatability of tests. The BET analysis showed that the NAM is predominantly a mesoporous powder. The FTIR and XRD analyses confirmed that the NAM is pure calcite with unique water absorbing characteristics, and is free of bacteria. The EDX and ICP-OES analyses revealed calcium, oxygen and carbon as the major elemental composition of the NAM. The SEM and TEM images revealed irregular shaped particles in the NAM. The PSA analysis of the particle distribution showed the NAM to be superfine (50nm to 0.3µm) and medium (44µm powder), respectively. The TGA analysis revealed a high-grade carbonate product in the NAM (>66.0 mass% of calcium carbonates). In addition, and in terms of in the qualities of the NAM in reducing the surface roughness of PMMA resins, the test group and the control group produced Ra values that were significant different (p<0.0001). The SEM and OEM analyses further confirmed the differences in the surfaces between the polished sample groups at different magnifications. Overall, the control showed the highest mean average (0.1056±0.03688µm), whereas the test group had the lowest Ra values (0.0476±0.01379). The lowest Ra values measured with the test group indicated that the NAM improves the surface smoothness of PMMA acrylic specimens. Notably, this study conclusively showed that the NAM effectively reduces the surface roughness to below the threshold limit value of 0.2µm. Significantly, and in associating the Ra values to the threshold limit value of 0.2µm, the NAM produced better results than pumice. Hence the use of the NAM as a polishing material for acrylic dentures is highly recommended. Finally and in line the NAM being a suitable alternative to pumice as it effectively reduces the surface roughness of PMMA specimens, future investigation into the use of eggshell nanoparticles to develop dental prophylaxes will be encouraged. / M

Page generated in 0.048 seconds