• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 29
  • 29
  • 29
  • 29
  • 22
  • 22
  • 22
  • 20
  • 16
  • 11
  • 11
  • 8
  • 8
  • 8
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysis

Toniollo, Marcelo Bighetti 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
22

Cantilever em Próteses: análise da deformação de estruturas metálicas em NiCr, com diferentes configurações, em função da carga aplicada

Alves, Luciana Mara Negrão [UNESP] 13 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-13Bitstream added on 2014-06-13T19:37:34Z : No. of bitstreams: 1 alves_lmn_me_araca.pdf: 553895 bytes, checksum: fdd3818f3f8b58690b7a2926bef25da6 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O êxito clínico nos tratamentos com próteses fixas implanto-suportadas com cantilever é determinado pela maneira como o estresse mecânico é transferido ao implante e ao tecido ósseo circundante sem gerar forças de grande magnitude e pelo estado de saúde dos tecidos adjacentes. Nestes tratamentos, as tensões oclusais se concentram nas extensões distais havendo uma maior incidência de fratura da estrutura, na união entre a prótese e o implante mais distal. Reconhecendo a influência do desenho da estrutura do cantilever sobre os implantes, bem como a necessidade dessas terem formatos que facilitem a higienização e manutenção do tecido periimplantar, o objetivo desse estudo será analisar a relação entre a força aplicada e a deformação ocorrida em barras para cantilever, com áreas de secção transversal em forma de triangulo, quadrada, semi lua, em L e I, através de uma Máquina de Ensaio Universal “EMIC”. Serão confeccionadas 25 barras, em liga de NiCr, divididas em 5 grupos, um para cada formato de barra, com 5 corpos de prova cada um. Uma carga vertical de 200N será aplicada na extremidade do segmento de 15 mm, com velocidade de 0,5mm por minuto. As barras que suportaram uma maior carga foram as em formato quadrado, seguida pela meia lua, L, triangular sendo a em formato de I a que suporta menor força de mordida. Houve diferenças estatisticamente significantes quando comparadas as em formato quadrado em relação às outras formas e as em meia lua também com as outras formas, sendo que as em formato de L, I e triangular não apresentaram diferenças estatisticamente significantes. É importante definirmos corretamente o formato da secção transversal da barra do cantilever de uma prótese, em função de sua relação com a classe de prótese antagônica, para que não haja deformação durante a função proporcionando estruturas leves, confortáveis e com espaço suficiente para higienização / The clinical success in treatment with implant-supported fixed prostheses with cantilever is determined by how the mechanical stress is transferred to the implant and the surrounding bone without generating forces of great magnitude and the health of tissues. In these treatments, the occlusal stress focus on the distal extensions and a higher incidence of fracture of the structure, the bond between the prosthesis and the most distal implant. Recognizing the influence of the cantilever design of the structure on implants, and the need to have these formats to facilitate the cleaning and maintenance of peri-implant tissue, the aim of this study will examine the relationship between the applied force and deformation occurred in bars for cantilever with areas of cross section in the shape of triangle, square, half moon, L and I, through a Universal Testing Machine EMIC. 25 bars will be made in NiCr, divided into five groups, one for each bar shape, with five specimens each. 200N of a vertical load is applied at the end of the segment of 15mm with a speed of 0.5 mm per minute. The bars that bore a greater burden were square in shape, then the half moon, L, and the triangular-shaped supports that I less bite force. There were statistically significant differences when comparing the square in shape relative to other forms and in a half-moon also with other forms, and the L-shaped, triangle and I did not show statistically significant differences. It is important to properly define the shape of the cross section bar of the cantilever of a prosthesis, because of its relationship with the class of prosthesis antagonistic, so that no deformation during function, providing lightweight structures, comfortable with enough space for cleaning
23

Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysis

Marcelo Bighetti Toniollo 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
24

Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser / Photoelastic analysis of the distribution of the tensions in two systems of mandibular prosthesis over implants : distal bar and laser welding

Salles, Angelo Emilio Barroso de 12 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1 Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5) Previous issue date: 2008 / Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal. / Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
25

Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis

Edson Koji Takeshita 01 September 2011 (has links)
A técnica All-on-Four foi idealizada visando diminuir a extensão do cantilever nas reabilitações de pacientes edêntulos com próteses implantossuportadas. Contudo, ainda persistem questionamentos relacionados ao comportamento biomecânico dos implantes e da própria técnica All-on-Four, posto que, questões como a perda óssea peri-implantar e falência de componentes da prótese ainda não estão claramente elucidadas. O objetivo da pesquisa foi avaliar a dissipação de tensões em próteses implantossuportadas dos tipos Branemark e All-on-Four, sob carga oclusal estática, e o papel do lado de balanceio e do comportamento do complexo implantes/próteses. Foram confeccionadas seis réplicas de mandíbula humana em resina fotoelástica, divididas em dois grupos:um com quatro implantes dispostos axialmente e paralelas entre si no espaço interforaminal (mandíbulas Branemark), e outro com quatro implantes inseridos de acordo com a técnica All-on-Four. Confeccionou-se uma prótese total implantossuportada, de maneira que se adaptasse em todas as seis mandíbulas. O experimento foi conduzido com o auxílio de um dispositivo giratório de carga, que permitiu a visualização das mandíbulas por todos os ângulos, sem alteração da carga aplicada. Após a fixação padronizada do corpo de prova no dispositivo, a prótese foi parafusada sobre os implantes da mandíbula. Os carregamentos de carga foram feitos em três pontos: no cantilever da prótese, no primeiro pré-molar e na incisal dos incisivos centrais inferiores. Para cada ponto de aplicação das cargas, fotografaram-se as mandíbulas nos lados de trabalho, de balanceio e na linha mediana, vestibular e na linha mediana também por lingual. Pelos resultados observados, quando as cargas foram aplicadas em regiões mais anteriores da prótese, as tensões nos implantes distais inclinados atenuaramse e as outras regiões da mandíbula apresentaram tensões menores e melhor distribuídas. As franjas também mostraram que a angulação dos implantes distais promoveu mudanças no eixo de rotação do conjunto implantes/prótese. Assim como verificou-se que o implante mais distal do lado de balanceio mostrou atuação conjunta com o implante distal do lado de trabalho nas mandíbulas com implantes axiais e, o mais distal do lado de balanceio nas mandíbulas com implantes inseridos segundo a técnica All-on-Four, mostrou tensão nos ápices, denotando função de estaca. Pela metodologia empregada foi possível concluir que, uma prótese total implantossuportada, segundo a técnica All-on-Four, apresentou melhor melhor dissipação das cargas oclusais e o lado de balanceio teve papel fundamental no auxílio à dissipação de cargas oclusais. / The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosthetic components are not yet clearly elucidated. The purpose of the study was to evaluate the dissipation of tensions in the Branemark implant-supported prosthesis and All-on-Four, under static occlusal load, and the role of the balancing side and the complex behavior of implants / prostheses. Six replicas of the human mandible were made in photoelastic resin, divided into two groups: one with four implants placed axially and parallel to each other in interforaminal space (Branemark jaws), and another four implants inserted according to the All-on-Four technique. It was made an implant-supported denture, so that would fit in all six jaws. The experiment was conducted with the aid of a rotating load device, which permitted visualization of the jaws from all angles, without changing the applied load. After the standardized setting of specimen in the device, the prosthesis was screwed onto the implants in the jaw. The cargo shipments were made on three points: the cantilever prosthesis, in the first premolar and the lower central incisor incisal. For each point of application of loads, photograph was taken from the work sides of the jaws, balancing and the midline, bucal view and the midline lingual also. By the observed results, when loads were applied to more anterior regions of the prosthesis, the stresses in the distal inclined implants attenuated and other regions of the mandible showed lower stresses and better distributed. The fringes also showed that the angulation of the distal implants promoted changes in the axis of rotation of the implant / prosthesis. As it was found that the most distal implantat on the balancing side showed joint action with the distal implant of the working side in the jaw with axial implants, and the most distal implant on the balancing side of jaw with implants inserted according to All-on Four technique, the tension showed apices, denoting stake function. For the methodology it was concluded that an implant-supported denture, according to the All-on-Four technique, had a better dissipation of occlusal loads and balancing side was fundamental hole in helping to dissipate occlusal loads.
26

Bone regeneration in novel porous titanium implants

Khouja, Naseeba, 1981- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The objective of this study was to evaluate the in vivo performance of the novel press-fit dental implant fabricated via electron beam melting (EBM, Southern Methodist Univ.) and compare it to a commercially-available porous-coated press-fit dental implant (Endopore, Innova Corp.). Twelve cylindrical shaped implants 3 mm in diameter x 5 mm long were made by EBM (Southern Methodist Univ.) using Ti6Al4V ELI alloy. Twelve commercial implants (Endopore, Innova Corp.) of the same geometry were used as controls. Samples were implanted in rabbit tibia and retrieved six weeks postoperatively. Six specimens from each implant type were embedded undecalcified, sectioned, and stained with toluidine blue (Sigma) for histomorphometry analysis. Bone-to-implant contact (BIC) was measured. On the six remaining samples from each implant type, the mechanical properties were evaluated by pushout test on a material testing machine. The samples were loaded at a loading rate of 1 mm/min. The pushout strength was measured and the apparent shear stiffness was calculated. The results were analyzed with a paired-t test. The histology shows osteointegration of surrounding bone with both implant types. Bone was found to grow into the porous space between the beads. Both the Endopore (Innova Corp.) and the EBM (Southern Methodist Univ.) showed similar BIC. The mean BIC for the Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implant were 35 ± 6% and 32 ± 9%, respectively. It failed to reach statistical significance (p > 0.05). The peak pushout force for Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implants were 198.80 ± 61.29 N and 243.21 ± 69.75 N, respectively. The apparent shear stiffness between bone and implant for the Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implants were 577.36 ± 129.99 N/mm; and 584.48 ± 146.63 N/mm, respectively. Neither the peak pushout force nor the apparent shear stiffness of the implants was statistically different between the two groups (p > 0.05). The results suggest that the implants manufactured by EBM (Southern Methodist Univ.) perform equally well as the commercial implant Endopore (Innova Corp.) in this current animal model.
27

Avalia??o cl?nica e radiogr?fica das complica??es t?cnicas em pr?teses sobre implantes

Dantas, Poliana Medeiros Cunha 13 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:52Z (GMT). No. of bitstreams: 1 PolianaMCD_DISSERT.pdf: 1792247 bytes, checksum: 7f68d2f3ec1dcc9a4fd54fc8a9e991be (MD5) Previous issue date: 2012-12-13 / The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components / Os crit?rios de avalia??o dos casos tratados com implantes osseointegrados s?o baseados em testes cl?nicos e exames radiogr?ficos. Nesse contexto, ? importante a realiza??o de pesquisas na determina??o do progn?stico dos diferentes tipos de reabilita??es prot?ticas e na determina??o dos principais problemas que atingem este tipo de tratamento. Desta forma, o objetivo deste trabalho foi avaliar as condi??es prot?ticas de indiv?duos reabilitados com implantes osseointegrados e pr?teses sobre implantes. Neste estudo transversal foram atendidos 153 pacientes, contabilizando uma amostra de 509 implantes. As falhas foram observadas atrav?s do exame cl?nico e radiogr?fico. Os resultados demonstraram que a fratura (0,2%), a perda (0,4%) e o afrouxamento dos parafusos (3,3%) foram as falhas menos frequentes. A fratura das estruturas como a resina (12,4%), porcelana (5,5%) e met?lica (1,5%), a perda da resina que recobre o parafuso de fixa??o (23,8%) e a perda de reten??o nas pr?teses overdentures (18,6%), tiveram uma ocorr?ncia maior. A falha de adapta??o, entre o pilar e o implante (6,9%) e principalmente entre a pr?tese e o pilar (25,4%) teve uma alta preval?ncia e, quando relacionada com outros par?metros, demonstrou uma associa??o significativa, principalmente com a fixa??o do tipo cimentada (OR= 5,39). Pode-se concluir que para minimizar o aparecimento de falhas, protocolos devem ser observados desde o diagn?stico at? o assentamento e controle das pr?teses sobre implantes, principalmente com rela??o aos passos t?cnicos da confec??o da pr?tese e com o cuidado em avaliar radiograficamente a adapta??o entre seus componentes
28

Influ?ncia da t?cnica de fabrica??o e dos materiais sobre o ajuste da interface pilar/implante em infraestruturas implantossuportadas

Franca, Danilo Gonzaga Bernardo de 22 March 2013 (has links)
Made available in DSpace on 2014-12-17T15:43:52Z (GMT). No. of bitstreams: 1 DaniloGBF_DISSERT.pdf: 1485726 bytes, checksum: 4640fbe2db551567fc003e0585ff8950 (MD5) Previous issue date: 2013-03-22 / The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Br?nemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ? 3.6, 107.2 ? 36), CoCrcad (1.2 ? 2.2, 107.5 ? 26 ), CoCrUCci (11.8 ? 9.8, 124.7 ? 74), CoCrUCc (12.9 ? 11.0, 108.8 ? 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology / O objetivo deste estudo foi comparar o desajuste vertical, horizontal e a passividade de infraestruturas fabricadas em zirc?nia e cobalto-cromo por tecnologia CAD/CAM e pelo m?todo da fundi??o convencional. Dezesseis infraestruturas em monobloco, foram obtidas a partir de uma matriz met?lica contendo tr?s implantes Br?nemark compat?veis de plataforma regular (Titamax Cortical Ti, Neodent). Oito infraestruturas foram confeccionadas pelo sistema CAD/CAM (NeoShape, Neodent): quatro em zirc?nia (Zircad) e quatro em cobalto-cromo (CoCrcad). Outras oito infraestruturas foram obtidas pelo m?todo da fundi??o convencional: quatro em cobalto-cromo com pilar UCLA cinta Co-Cr (CoCrUCci) e quatro em cobalto-cromo com pilar UCLA calcin?vel (CoCrUCc). O ajuste vertical, horizontal e a passividade pelo teste do parafuso ?nico foram mensurados usando microscopia eletr?nica de varredura com aumento de 250x. Inicialmente avaliou-se a passividade pelo teste do parafuso ?nico e posteriormente para avaliar o desajuste vertical e horizontal, apertou-se todos os parafusos, com torque de 20Ncm. M?dia, desvio padr?o, valor m?nimo e m?ximo foram calculados para cada grupo. As medidas de desajuste horizontal foram transformadas em frequ?ncia cumulativa para categoriza??o da vari?vel e posterior compara??o grupos a grupo. Para avaliar a exist?ncia de diferen?as quantitativas entre os grupos testados para desajuste vertical e passividade, foi usado o teste Kruskal-Wallis. O teste Mann-Whitney foi usado para comparar as diferen?as estat?sticas grupo a grupo (p<0,05). Foram observados os respectivos valores de m?dia e desvio padr?o em micr?metros para desajuste vertical e passividade: Zircad (5,9 ? 3,6; 107,2? 36), CoCrcad (1,2 ? 2,2; 107,5? 26), CoCrUCci (11,8 ? 9,8; 124,7? 74), CoCrUCc (12,9 ? 11,0; 108,8? 85). Observaram-se diferen?as estat?sticas para medidas de desajuste vertical (p=0,000). O teste Mann-Whitney revelou diferen?as estat?sticas (p<0,05) entre todos os grupos, exceto entre CoCrUCci e CoCrUCc (p=0,619). Nenhuma diferen?a estat?stica foi observada para a passividade das infraestruturas. Em rela??o ao desajuste horizontal, os grupos ZirCAD e CoCrcad n?o apresentaram melhores valores em rela??o a CoCrUCci e CoCrUCc. Baseado nos resultados pode-se concluir que infraestruturas confeccionadas por tecnologia CAD/CAM obtiveram melhores valores de ajuste vertical que aquelas fabricadas pelo m?todo da fundi??o, apesar disso, a passividade das infraestruturas n?o foi influenciada pela t?cnica de fabrica??o e material utilizado. O ajuste horizontal obtido pelas infraestruturas fabricadas por CAD/CAM n?o foi superior ?quelas fabricadas por fundi??o. Uma menor variabilidade no ajuste vertical e na passividade foi observada quando infraestruturas foram fabricadas por tecnologia CAD/CAM
29

Uticaj metoda otiskivanja i angulacije implanata na tačnost definitivnog radnog modela za izradu implantno nošenih zubnih nadoknada / The impact of impression methods and implant angulation to the accuracy of the definitive working cast for the production of implant-supported dental restorations

Đurović Koprivica Daniela 13 October 2017 (has links)
<p>U uvodnom delu doktorske disertacije opisane su osnovne konvencionalne metode otiskivanja, kao i modifikovane tehnike koje se koriste u savremenoj implant protetici. Prikazana je specifičnost biomehanike implantno no&scaron;enih i poduprtih nadoknada u odnosu na biomehaniku nadoknada retiniranih prirodnim zubima. Akcenat je stavljen na kompleksnost problematike postizanja apsolutno pasivnog naleganja nadoknade na nosač implanta (abatment), sa posebnim osvrtom na uticaj same procedure otiskivanja implanata i angulacije implanata na tačnost naleganja. Detaljno su opisani i svi ostali faktori koji mogu da utiču na tačnost radnih modela pri izradi nadoknada na implantima, pozivajući se na aktuelne podatke iz literature i naučno opravdanje za potrebe istraživanja. Cilj rada je bio ispitati uticaj metode otiskivanja, angulacije implanata i vrste otisnog materijala na tačnost definitivnog radnog modela za izradu implantno no&scaron;enih zubnih nadoknada. Eksperiment je obavljen u in vitro uslovima. Istraživanje je bazirano na ispitivanju tačnosti otiskivanja pomoću tri različite metode otiskivanja (direktne, indirektne i modifikovane &bdquo;splint&ldquo; metode), dve vrste elastičnih otisnih materijala (adicionog silikona i polietra) i uticaja dve različite grupe implanata (anguliranih od 20&deg; i paralelnih implanata) na tačnost otiskivanja. Master (referentni) model je isplaniran tako da simulira čest klinički slučaj parcijalne bezubosti gornje vilice (klasa Kenedi I), koji je osim dva ugrađena angulirana implanta sa jedne, i dva paralelna implanta sa druge strane, podrazumevao i prisustvo bru&scaron;enih zuba, pripremljenih za prihvatanje keramičkog mosta u frontalnoj regiji. Otiskivanje zuba i implanata vr&scaron;eno je istovremeno i drugi deo istraživanja je obuhvatao ispitivanje uticaja primenjene metode i materijala na tačnost otisnutih povr&scaron;ina zuba. Time je pro&scaron;ireno polje istraživanja i omogućeno dono&scaron;enje zaključka o pravoj indikaciji metode i materijala za otiskivanje konkretnog kliničkog slučaja. Kompletna metodologija izrade master i definitivnih radnih (replika) modela, kao i sama procedura otiskivanja, izvedena je po najsavremenijim principima istraživanja, uz upotrebu instrumenata i materijala vodećih svetskih proizvođača. Za potrebe analize odstupanja implanata i zuba na replica modelima u odnosu na referentni, modeli su podvrgnuti optičkoj 3D (trodimenzionalnoj) digitalizaciji pomoću dva savremena laboratorijska skenera koje karakteri&scaron;e izuzetna tačnost skeniranih povr&scaron;ina. Prvo je digitalizovan master model za potrebe dobijanja nominalne geometrije, a nakon toga 30 replika modela, za potrebe uporedne geometrijske analize. Analiza je vr&scaron;ena pomoću najnovijeg specijalizovanog softverskog programa, primenom metode CAD-inspekcije (eng. Computer-Aided Design). Geometrijska analiza odstupanja bru&scaron;enih zuba (patrljaka) izvedena je tehnikom preklapanja odnosno superpozicije (eng. bestfit) realne geometrije (na replika modelu) sa nominalnom geometrijom (na master modelu). Za razliku od analize patrljaka, za potrebe geometrijske analize odstupanja implanata kreiran je lokalni koordinatni sistem za svaki analizirani implant, pomoću specijalnih abatmenta upotrebljenih za digitalizaciju i uvozom 3D modela implanata iz CAD biblioteke proizvođača. Odstupanja su analizirana u odnosu na centar baze implanta (odstupanje od centra) i u odnosu na centralnu osu implanta (ugao odstupanja), &scaron;to je omogućilo tačno prostorno orijentisanje implanata na replika modelima u poređenju sa referentnim. Ova metodologija je originalna, jer je u odnosu na metodologije koje su do sada kori&scaron;ćene u svrhu prostorne orijentacije implanata, uvođenjem novih parametara u analizu, omogućila tačnije defi nisanje prostornog odstupanja analiziranih implanata. Rezultati dobijeni u istraživanju doveli su do zaključka da metoda otiskivanja i vrsta otisnog materijala utiču na tačnost otiskivanja implanata. Takođe, angulacija implanata od 20&deg; ima veći uticaj na tačnost definitivnih radnih modela u poređenju sa paralelnim angulirana implanta sa jedne, i dva paralelna implanta sa druge strane, podrazumevao i prisustvo bru&scaron;enih zuba, pripremljenih za prihvatanje keramičkog mosta u frontalnoj regiji. Otiskivanje zuba i implanata vr&scaron;eno je istovremeno i drugi deo istraživanja je obuhvatao ispitivanje uticaja primenjene metode i materijala na tačnost otisnutih povr&scaron;ina zuba. Time je pro&scaron;ireno polje istraživanja i omogućeno dono&scaron;enje zaključka o pravoj indikaciji metode i materijala za otiskivanje konkretnog kliničkog slučaja. Kompletna metodologija izrade master i definitivnih radnih (replika) modela, kao i sama procedura otiskivanja, izvedena je po najsavremenijim principima istraživanja, uz upotrebu instrumenata i materijala vodećih svetskih proizvođača. Za potrebe analize odstupanja implanata i zuba na replika modelima u odnosu na referentni, modeli su podvrgnuti optičkoj 3D (trodimenzionalnoj) digitalizaciji pomoću dva savremena laboratorijska skenera koje karakteri&scaron;e izuzetna tačnost skeniranih povr&scaron;ina. Prvo je digitalizovan master model za potrebe dobijanja nominalne geometrije, a nakon toga 30 replika modela, za potrebe uporedne geometrijske analize. Analiza je vr&scaron;ena pomoću najnovijeg specijalizovanog softverskog programa, primenom metode CAD-inspekcije (eng. Computer-Aided Design). Geometrijska analiza odstupanja bru&scaron;enih zuba (patrljaka) izvedena je tehnikom preklapanja odnosno superpozicije (eng. bestfit) realne geometrije (na replika modelu) sa nominalnom geometrijom (na master modelu). Za razliku od analize patrljaka, za potrebe geometrijske analize odstupanja implanata kreiran je lokalni koordinatni sistem za svaki analizirani implant, pomoću specijalnih abatmenta upotrebljenih za digitalizaciju i uvozom 3D modela implanata iz CAD biblioteke proizvođača. Odstupanja su analizirana u odnosu na centar baze implanta (odstupanje od centra) i u odnosu na centralnu osu implanta (ugao odstupanja), &scaron;to je omogućilo tačno prostorno orijentisanje implanata na replika modelima u poređenju sa referentnim. Ova metodologija je originalna, jer je u odnosu na metodologije koje su do sada kori&scaron;ćene u svrhu prostorne orijentacije implanata, uvođenjem novih parametara u analizu, omogućila tačnije definisanje prostornog odstupanja analiziranih implanata. Rezultati dobijeni u istraživanju doveli su do zaključka da metoda otiskivanja i vrsta otisnog materijala utiču na tačnost otiskivanja implanata. Takođe, angulacija implanata od 20&deg; ima veći uticaj na tačnost definitivnih radnih modela u poređenju sa paralelnim implantima. Time su potvrđene radne hipoteze doktorske disertacije. &bdquo;Splint&ldquo; metoda otiskivanja i adicioni silikon izdvojili su se kao najtačniji pri otiskivanju implanata. Kombinacije &bdquo;splint&ldquo; metode sa adicionim silikonom i polietrom i otvorene metode sa adicionim silikonom dale su bolje rezultate pri otiskivanju anguliranih implanta, dok je u grupi paralelnih implanata zaključeno da metoda i materijal ne utiču na tačnost otiskivanja. &bdquo;Splint&ldquo; i otvorena metoda i adicioni silicon pružili su najtačnije otiske bru&scaron;enih zuba. &bdquo;Splint&ldquo; metoda u kombinaciji sa adicionim silikonom dala je najmanja ukupna odstupanja pri otiskivanju implanata i zuba zajedno. Prezentovana studija je specifi čna, kako po izboru zadatog kliničkog slučaja I uporednoj analizi tačnosti istovremenog otiskivanja implanata i zuba, tako i po samoj metodologiji analiza odstupanja implanata, te predstavlja originalni doprinos naučnoj i stručnoj javnosti.</p> / <p>The introductory part of the PhD-theses describes fundamental conventional impression methods, as well as modified techniques used in modern-day implant prosthetics. The biomechanics specificity of the implant supported prosthesis in relation to the biomechanics of natural-teeth retained prosthetics is showed. The emphasis is on the issue&rsquo;s complexity at accomplishing the absolute passive fit of the prosthesis onto the abutment, with particular regard to the impact of the implant impression procedure and implant angulation its elf. A detailed description is provided for all other factors which can influence the accuracy of working casts during implant-based dental prosthesis, making reference to the current data in the literature, as well as to the scientific justification for research. The aim of the study was to examine the influence of the impression method, implant angulation and type of the impression material on the accuracy of the definitive working model for production of the implant-supported dental prosthesis. The experiment was conducted in the in vitro conditions. The research is based on examining the impression accuracy by using three different impression methods (direct, indirect, as well as modifi ed &ldquo;splint&rdquo; method), by using two types of elastic impression materials (addition silicone and polyether), as well as the impact from two different implant groups (angled at 20&deg;, and parallel ones). Master (referential) model was planned to simulate a common clinical case of the upper jaw partial edentulism (Kennedy 1st class), which apart from the two angulated implants on one side, and two parallel implants on the other, also presupposed presence of milled teeth, prepared to accept ceramic dental bridge in the frontal region. Impression of teeth and implants was conducted simultaneously, and second part of the research encompassed examination of the applied method&rsquo;s and material&rsquo;s impact onto accuracy of the impressed teeth surfaces. This expanded the research fi eld and enabled drawing conclusions regarding the appropriate method indication and material for impression of a particular clinical case. Complete production methodology of master and definitive working casts (replicas), as well as the impression procedure itself, were all conducted according to the cutting-edge research principles, as well as with the application of instruments and materials of leading world producers. For the purpose of the analysis of implants and teeth deviation on replica models in relation to the reference model, the models underwent optical 3D (three-dimenzional) digitalization by using two state-of-the-art laboratory scanners characterized by exceptional accuracy of scanned surfaces. First model to be digitalized was the master one, in order to obtain nominal geometry, following which 30 model replicas were scanned, for the purpose of comparative geometrical analysis. The analysis was conducted by using latest specialized software designed for CAD (Computer-Aided Design) inspection method. Geometric analysis of the milled teeth (tooth abutments) deviation was conducted by using the overlapping superposition technique (bestfit) real geometry (on the replica model) with nominal geometry (on the master model). As opposed to the teeth-stump analysis, for the purpose of geometrical analysis of implant deviations, a local coordinate system for each analyzed implant was created, by using special abutments used for digitalization and by importing 3D implant models from the manufacturer&rsquo;s CAD library. Deviations were analyzed in relation to the implant base center (deviation from the center), and in relation to the implant central axis (deviation angle), which enabled accurate implant spatial orientation on the replica models in comparison the referential ones. This methodology is original, since unlike methodologies used so far for implant spatial orientation, it has enabled, through introducing new parameters into analysis, a more accurate defining of analyzed implants spatial deviation. Results obtained during research have led to the conclusion that that the impression methodology and type of the impression material influence the implant impression accuracy. Also, implant angulation of 20&deg; has a higher impact on accuracy of definitive working models in comparison with parallel implants. This confirms the PhD-thesis working hypotheses. The &ldquo;splint&rdquo; impression method and addition silicone have excelled as most accurate at implant impression. Combination of &ldquo;splint&rdquo; methods with addition silicone and polyether and opened methods with addition silicone proved to obtain better results when impressing angulated implants, while in the group of parallel implants, it was concluded that the method and material do not infl uence the impression accuracy. The &ldquo;splint&rdquo; and the open method and addition silicone provided most accu rate imprints of ground teeth. The &ldquo;splint&rdquo; method in com bination with addition silicone provided the least over all deviation at impression of implants and teeth together. The presented study is a specifi c one, both in terms of selection of the given clinical case and comparative analysis of the simultaneous impression of teeth and implants, but also in terms of the methodology itself used to analyze implant deviation, which in its own right represents an original contribution to the scientific and expert public.</p>

Page generated in 0.1122 seconds