Biodegradation of Dental Resin Composites and Adhesives by Streptococcus mutans: An in vitro Study

Bourbia, Maher 21 November 2013 (has links)
A major cause for dental resin composite restoration replacement is secondary caries attributed to Streptococcus mutans. Salivary esterases were shown to degrade resin composites. Hypothesis: S. mutans contain esterase activities that degrade dental resin composites and adhesives. Esterase activities of S. mutans were measured using synthetic substrates. Standardized specimens of resin composite (Z250), total-etch (Scotchbond-Multipurpose, SB), and self-etch (Easybond, EB) adhesives were incubated with S. mutans UA159 for up to 30 days. Quantification of a bisphenol-glycidyl-dimethacrylate (BisGMA)-derived biodegradation by-product, bishydroxy-propoxy-phenyl-propane (BisHPPP) was performed using high performance liquid chromatography. Results: S. mutans were shown to contain esterase activities in levels comparable to human saliva. A trend of increasing BisHPPP release throughout the incubation period was observed for all materials and was elevated in the presence of bacteria vs. control for EB and Z250 (p<0.05) but not SB. Conclusion: biodegradation by cariogenic bacteria could compromise the resin-dentin interface and reduce the longevity of the restoration.
2

Biodegradation of Dental Resin Composites and Adhesives by Streptococcus mutans: An in vitro Study

Bourbia, Maher 21 November 2013 (has links)
A major cause for dental resin composite restoration replacement is secondary caries attributed to Streptococcus mutans. Salivary esterases were shown to degrade resin composites. Hypothesis: S. mutans contain esterase activities that degrade dental resin composites and adhesives. Esterase activities of S. mutans were measured using synthetic substrates. Standardized specimens of resin composite (Z250), total-etch (Scotchbond-Multipurpose, SB), and self-etch (Easybond, EB) adhesives were incubated with S. mutans UA159 for up to 30 days. Quantification of a bisphenol-glycidyl-dimethacrylate (BisGMA)-derived biodegradation by-product, bishydroxy-propoxy-phenyl-propane (BisHPPP) was performed using high performance liquid chromatography. Results: S. mutans were shown to contain esterase activities in levels comparable to human saliva. A trend of increasing BisHPPP release throughout the incubation period was observed for all materials and was elevated in the presence of bacteria vs. control for EB and Z250 (p<0.05) but not SB. Conclusion: biodegradation by cariogenic bacteria could compromise the resin-dentin interface and reduce the longevity of the restoration.
3

Biodegradation of Dental Resin Composites and Adhesives by Streptococcus mutans: An in vitro Study

Bourbia, Maher 21 November 2013 (has links)
A major cause for dental resin composite restoration replacement is secondary caries attributed to Streptococcus mutans. Salivary esterases were shown to degrade resin composites. Hypothesis: S. mutans contain esterase activities that degrade dental resin composites and adhesives. Esterase activities of S. mutans were measured using synthetic substrates. Standardized specimens of resin composite (Z250), total-etch (Scotchbond-Multipurpose, SB), and self-etch (Easybond, EB) adhesives were incubated with S. mutans UA159 for up to 30 days. Quantification of a bisphenol-glycidyl-dimethacrylate (BisGMA)-derived biodegradation by-product, bishydroxy-propoxy-phenyl-propane (BisHPPP) was performed using high performance liquid chromatography. Results: S. mutans were shown to contain esterase activities in levels comparable to human saliva. A trend of increasing BisHPPP release throughout the incubation period was observed for all materials and was elevated in the presence of bacteria vs. control for EB and Z250 (p<0.05) but not SB. Conclusion: biodegradation by cariogenic bacteria could compromise the resin-dentin interface and reduce the longevity of the restoration.
4

Biodegradation of Dental Resin Composites and Adhesives by Streptococcus mutans: An in vitro Study

Bourbia, Maher 21 November 2013 (has links)
A major cause for dental resin composite restoration replacement is secondary caries attributed to Streptococcus mutans. Salivary esterases were shown to degrade resin composites. Hypothesis: S. mutans contain esterase activities that degrade dental resin composites and adhesives. Esterase activities of S. mutans were measured using synthetic substrates. Standardized specimens of resin composite (Z250), total-etch (Scotchbond-Multipurpose, SB), and self-etch (Easybond, EB) adhesives were incubated with S. mutans UA159 for up to 30 days. Quantification of a bisphenol-glycidyl-dimethacrylate (BisGMA)-derived biodegradation by-product, bishydroxy-propoxy-phenyl-propane (BisHPPP) was performed using high performance liquid chromatography. Results: S. mutans were shown to contain esterase activities in levels comparable to human saliva. A trend of increasing BisHPPP release throughout the incubation period was observed for all materials and was elevated in the presence of bacteria vs. control for EB and Z250 (p<0.05) but not SB. Conclusion: biodegradation by cariogenic bacteria could compromise the resin-dentin interface and reduce the longevity of the restoration.
5

Avaliação da resistência ao desgaste de uma resina composta odontológica nanoparticulada empregando diferentes tempos de fotopolimerização

Souza, Celso Naves de [UNESP] 10 November 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-11-10Bitstream added on 2014-06-13T19:22:34Z : No. of bitstreams: 1 souza_cn_dr_guara.pdf: 5417862 bytes, checksum: 45f7392a335fde8b9a67ef7d60be0ce9 (MD5) / Este trabalho tem como objetivo avaliar a influência dos tempos de fotopolimerização nas resinas odontológicas, onde quatro resinas compostas foram utilizadas, sendo três micro híbridas e uma nanoparticulada. Esses compósitos foram submetidos ao desgaste abrasivo de esfera rotativa pelo método de ball cratering. Para tal ação foi projetado e construído um dispositivo de desgaste por micro abrasão de esfera rotativa livre de três corpos. Os corpos de prova foram confeccionados e embutidos em uma matriz de alumínio, com uma profundidade de 2mm. Usam-se o aparelho LED RADII, com os tempos de exposição de 20, 30 e 40 segundos e uma esfera com 15 mm de diâmetro de aço temperada, retificada e revenida. A lama abrasiva utilizada nesse estudo foi uma solução composta por 20% de talco (USP/200) e 80% de soro fisiológico, na quantidade de 3 gotas por segundo. Para comprovação dos resultados obtidos, utilizaram-se os testes de: Espectroscopia por Dispersão de Energia (EDS), Infravermelho por Transformada de Fourier (FT-IR), Análise Termogravimétrica (TGA), micro dureza Vickers, ensaio de desgaste de micro abrasão por esfera rotativa pelo método de ball cratering e a análise da superfície desgastada por Microscopia Eletrônica de Varredura (MEV). Esta análise foi realizada para verificar o real mecanismo de desgaste ocorrido. Os resultados obtidos comprovam que o tempo recomendado pelos fabricantes, tem a capacidade suficiente de fotopolimerizar toda a matriz orgânica, comprovaram também que a resina nanoparticulada obteve em todos os ensaios os melhores resultados em relação às resinas híbridas, e que a cultura do acréscimo de até 20s além do recomendado não tem influência direta em relação ao desgaste abrasivo. / This work has as an objective to evaluate the influence of photopolymerization in odontological resins, where composed four resins were used, being three of them micro hybrid and one nanoparticulated. These composites were submitted to abrasive wear and tear of rotative sphere by the method ball cratering. For such action a device of micro abrasion of rotative sphere was designed and built free of three bodies. The bodies of proof were produced and put in a matrix of aluminum with a depth of 2mm. The device used was a LED RADII, with exposition time of 20, 30 and 40 seconds and a sphere of 15mm diameter made of tempered steel, rectified and soften, the abrasive lama used in this study was a solution composed by 20% of powder (USP/200) and 80% of physiological serum released at 3 drops per second. For verification of the results obtained the tests of Energy Dispersion Spectrograph (EDS) was used, transformed Infra red of Fourier (FT-IR), Thermogravimetric Analysis (TGA) Vickers micro hardness, wear and tear of micro abrasion by rotative sphere by the method ball cratering and the analysis of worn superficies by Sweeping Electronic Microscopy (SEM). This analysis was carried out to verify the real mechanism of the worn occurred. The results obtained prove that the time recommended by the manufacturer has enough capacity to photopolymerized all the organic matrix, it also proved that the resin nanoparticulated obtained in all the essays the best results in what concerns to the hybrid resins. And the culture of the addition of 20 seconds besides what is recommended has no direct influence in relation to the abrasive wear and tear.
6

Efeito da adição de fosfato dicálcico dihidratado (DCPD) sobre as propriedades mecânicas e liberação de íons após imersão prolongada de compósitos experimentais / Effect of the addition of dicalcium phosphate dihidrate (DCPD) on mechanical properties and ion release after prolonged immersion of experimental composites

Maas, Mariel Soeiro 02 June 2017 (has links)
O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas diferenças estatisticamente significantes entre monômeros-base nos períodos de 1, 30 e 90 dias. O compósito contendo BisGMA apresentou liberações de fosfato estatisticamente maiores do que o material com BisEMA para todos os períodos de imersão, exceto após um dia. Após 60 dias a liberação de fósforo foi maior para ambos materiais em comparação aos 30 e 90 dias. Apenas para compósito contendo BisGMA foi verificada uma forte correlação linear entre liberação de cálcio e E (R2=0,990). Com base no exposto, pode-se concluir que: 1) o monômero-base utilizado afetou o GC dos materiais avaliados; 2) a presença de DCPD afetou a RFB inicial dos compósitos; 3) apenas os compósitos contendo BisGMA apresentaram reduções nas propriedades mecânicas após 90 dias; 4) ambos compósitos apresentaram diferenças nas concentrações finais de fosfato, mas não nas concentrações de cálcio liberadas; 5) houve correlação apenas entre liberação de cálcio e E de compósitos contendo BisGMA ao longo do período de imersão. Desta forma, todas as hipóteses nulas testadas devem ser rejeitadas. / The aim of the study was to evaluate the mechanical properties and ion release of experimental composites containing DCPD after different immersion periods. DCPD nanoparticles (10 vol%) were incorporated into equimolar mixtures of either BisGMA and TEGDMA or BisEMA and TEGDMA. Barium glass particles (50 vol%), 0,5% camphorquinone and 0,5% of ethyl 4-dimethylaminobenzoate were also added. Materials containing only barium glass particles (60 vol%) were considered as control groups. Degree of conversion (DC) was determined by near-FTIR (n=3). Biaxial flexural strength (BFS) and elastic modulus (E) were obtained through the biaxial flexural test. Fragments of the disk-shaped specimens tested in flexure were selected to perform the Knoop microhardness test (KHN). Specimens (n=10, 12x1mm) were tested after 1, 30, 60 and 90 days of immersion in NaCl solution (pH = 7.0). DC results were submitted to two-way ANOVA (\"monomer\" and \"presence of DCPD\"). KHN data were analyzed using three-way ANOVA (\"monomer\", \"presence of DCPD\" and \"immersion period\"). Multiple comparisons were made using Tukey test. BFS, E and ion release data were analyzed by Kruskal-Wallis/Dunn test (alpha = 5% in all cases). Regardless of the presence of DCPD, materials containing BisGMA presented statistically higher DC than materials containing BisEMA. Barium glass replacement by DCDP caused a reduction of the initial BFS for BisGMA and BisEMA composites and of initial E only for BisGMA. Materials containing BisGMA presented higher values of initial E and KHN. In general, composites containing BisGMA presented higher reductions in mechanical properties after 90 days. Thus, composites containing BisEMA presented higher final values of KHN (regardless of the presence of DCPD) and BFS (only for materials without DCPD). After 90 days, E and KHN values of materials with BisGMA were lower for the composite containing DCPD. Both composites showed increasing calcium release values during the 90 days, and no statistically significant differences were detected between composites with different monomers at 1, 30 and 90 days periods. BisGMA-containing composites showed a statistically higher phosphate release than the material with BisEMA in all immersion periods, except for one day period. After 60 days the phosphate release was higher for both materials when compared to 30 and 90 days period. Only for composite containing BisGMA a strong linear correlation between calcium release and E (R2 = 0.990) was verified. Based on the above, it can be concluded that: 1) the base-monomer affected the DC of the evaluated materials; 2) the presence of DCPD affected the initial BFS of the composites; 3) only BisGMA-containing composites showed reductions in mechanical properties after 90 days; 4) both composites showed differences in the final concentrations of phosphate, but not for the calcium concentrations; 5) there was a correlation only between calcium release and E of BisGMA-containing composites throughout the immersion period. Therefore, all null hypotheses tested were rejected.
7

Efeito da velocidade de polimerização na qualidade da impressão 3D DLP de uma resina odontológica experimental fotopolimerizável / Rate of polymerization effect in the quality of 3d dlp printed parts made with an experimental dental photocurable resin

Pivesso, Bruno Pasquini 27 June 2018 (has links)
A introdução de resinas para uso odontológico se estabeleceu como alternativa à restauração desde meados de 1930, onde a tentativa de utilizar resinas autocuráveis fracassou, porém fortaleceu a pesquisa e esforço em busca de uma alternativa mais viável. Atualmente, a maior parte das resinas odontológicas são fotocuráveis ou termocuráveis e neste trabalho será dado enfoque nas resinas fotopolimerizáveis, que são constituídas, principalmente, por um sistema iniciador (fotoiniciador), monômeros, oligômeros (cadeias maiores formada pela junção de monômeros), aditivos (como cargas, absorvedores de luz, entre outros) e pigmentos. Na última década, um setor que ganhou largas proporções e interesses tecnológicos é o da impressão 3D. Por se tratar de uma técnica aditiva (camada-a-camada) esta forma de impressão revolucionou o modo de se projetar e aplicar diversas estruturas na solução de problemas, inclusive na área odontológica. Dentre os diversos tipos de impressora 3D, a DLP (digital light projection) foi a que apresentou melhor relação de benefícios em função do seu custo reduzido, alta resolução e praticidade na impressão. O presente trabalho apresenta o estudo da influência da cinética de fotopolimerização na qualidade de peças impressas por meio de impressão 3D DLP e como este fator afeta propriedades físicas e químicas, tais como dureza e grau de conversão. Os experimentos de p-DSC juntamente com FT-IR mostraram como a presença de um bloqueador pode afetar a cinética de fotopolimerização e o grau de conversão a curto e longo prazo, onde para o BAPO observa-se uma baixa contribuição deste composto na redução da velocidade, mas para o TPO o resultado é mais acentuado. Com os dados de dureza, foi possível observar que a presença do bloqueador leva a uma diminuição do valor obtido. Já as fotomicrografias obtidas revelaram que o absorvedor UV apresentou grande contribuição para a resolução das peças impressas, com resultado mais significativo para o fotoiniciador TPO. Dados de DSC foram analisados para correlacionar com o monômero residual presente, onde foi observado um pico exotérmico com área praticamente constante em situações otimizadas, levando a uma conclusão que o máximo de resolução está diretamente relacionado com o grau de conversão obtido no processo de impressão 3D. / The introduction of resins for the dental Market was stablished around 1930, where the self-cure resins development failed and lead the world to develop a new alternative for dental application. Recently, most of the dental resin are photo curable or thermal curable and in the present work the first one will be the focus and are composed of an initiation system (photo-initiator), monomers, additives and pigments. In the past decade, another sector, which achieve large proportion and technological interest, is the one about 3D printing. Due to the fact of being an additive technique, this type of 3D printing made a revolution in the way of projecting and building complex structures, even in the dental business. Among all the available 3D printers, the DLP (digital light projection) is the one who showed the best relationship between price, resolution and convenience in 3D printing. This work presents a study of how the photopolimerization kinetics can affect the quality of 3D printed parts and how it affects some physical-chemical properties, like hardness and degree of conversion. The p-DSC experiments within the FT-IR showed that the presence of an UV blocker might affect the photopolimerization kinetics and the degree of conversion in a short and long term, in which for BAPO it shows a lower contribution from this compound in the reaction rate, but for TPO it is more marked. According to the hardness data, it was possible to observe that the presence of an absorber leads to a lower value. In respect to the photomicrographs, it reveals the good contribution of an UV blocker in the resolution obtained for the printed parts, with a better performance when added to the TPO case. For the DSC experiments, the observation is that there is a correlation with residual monomer, where an exothermic spike with constant area was present for the same optimized conditions, leading to the fact that to achieve the best resolution it is necessary to reach a certain degree of conversion during the process of 3D printing.
8

Efeito da concentração de argila nas propriedades termomecânicas de uma resina dentária modelo / Effects of organoclay loadings on the thermal mechanical properties of a model dental resin

Terrin, Marina Martins 18 October 2013 (has links)
Apesar dos vários avanços que levaram à expansão do uso de compósitos dentários, ainda há deficiências que limitam suas aplicações. A resistência inadequada ao desgaste mastigatório é constantemente citada como problema das resinas e que acaba tornando-se responsável parcialmente pela redução de sua vida útil. O desgaste do material ocorre pela perda ou degradação da matriz orgânica permitindo a exposição da matriz inorgânica e consequentemente levando a perda desta. Sendo assim, o presente trabalho tem como objetivo principal avaliar o efeito das diferentes concentrações de argila organofílica nas propriedades de uma resina dentária modelo. Primeiramente, foi realizada a purificação da argila e sua posterior troca iônica, o preparo das resinas experimentais e posterior adição de argila em diferentes concentrações, e finalmente a confecção dos corpos de prova. Então, as resinas foram avaliadas através de técnicas como o DMA, TGA, PCA, FTIR, DRX e por testes de inchamento para avaliar a absorção de água. Por FTIR e por PCA foi possível realizar o acompanhamento da cinética de reação das resinas preparadas, obtendo-se assim o seu grau de conversão e também uma análise da sua cinética de polimerização, sendo observado que em concentrações maiores de argila, o grau de conversão e a taxa de polimerização diminuíram. Por TGA foi possível observar dois picos no segundo processo de degradação térmica da amostra sem adição de argila, indicando uma polimerização não homogênea; conforme aumenta-se a quantidade de argila presente na mistura, os picos duplos tornam-se um. DMA mostrou discreto aumento da Tg e aumento de E\' e E\", indicando um reforço destes compósitos. DRX mostrou que não houve exfoliação da argila no polímero, podendo ter a formação de um compósito convencional ou de um compósito intercalado sem expansão do espaço interlamelar. Já os testes de inchamento mostraram que quanto maior o teor de argila maior a absorção de água das resinas. / In spite of the developments that led to the use of dental composites, there are still some shortcomings that limit their use. Inadequate resistance due to the mastigatory wearing is often cited as an issue in resins, which is partially responsible for reducing its lifetime. Wearing out of the material occurs by the loss or degradation of the organic matrix, thus allowing the inorganic matrix to become exposed and consequently leading to its loss. Therefore, the present work has as main goal the evaluation of the effect of different organoclay filler content in the properties of a experimental dental resin. For such, the clay was first purified and then underwent through cationic exchange, following preparation of the resins and later addition of the organoclay obtained and preparing the specimens. The, the resins were evaluated by techniques such as DMA, TGA, PCA, DRX and swelling tests to observe water sorption. By FTIR and PCA it was possible to follow the reaction kinectics of the prepared resins, thus obtaining the degree of convertion and polymerization rate, allowing to observe that the higher the organoclay loadings the lower was both the polymerization rate and the degree of convertion. TGA allowed us to observe two peaks on the second process of thermal degradation on the sample with no clay, thus indicating a non-homogeneous polymerization; and with higher clay loadings the double peaks become one single peak. DMA showed a slight increase of Tg and also an increase in E\' and E\", indicating a reinforcement of the obtained composites. DRX showed no exfoliation of the polymer, thus forming either a conventional composite or maybe a interlacated composite with no expansion of the interlamelar space. Swelling tests showed that the higher the amount of organoclay added the higher was the amount of water absorbed by the specimens.
9

Efeito da concentração de argila nas propriedades termomecânicas de uma resina dentária modelo / Effects of organoclay loadings on the thermal mechanical properties of a model dental resin

Marina Martins Terrin 18 October 2013 (has links)
Apesar dos vários avanços que levaram à expansão do uso de compósitos dentários, ainda há deficiências que limitam suas aplicações. A resistência inadequada ao desgaste mastigatório é constantemente citada como problema das resinas e que acaba tornando-se responsável parcialmente pela redução de sua vida útil. O desgaste do material ocorre pela perda ou degradação da matriz orgânica permitindo a exposição da matriz inorgânica e consequentemente levando a perda desta. Sendo assim, o presente trabalho tem como objetivo principal avaliar o efeito das diferentes concentrações de argila organofílica nas propriedades de uma resina dentária modelo. Primeiramente, foi realizada a purificação da argila e sua posterior troca iônica, o preparo das resinas experimentais e posterior adição de argila em diferentes concentrações, e finalmente a confecção dos corpos de prova. Então, as resinas foram avaliadas através de técnicas como o DMA, TGA, PCA, FTIR, DRX e por testes de inchamento para avaliar a absorção de água. Por FTIR e por PCA foi possível realizar o acompanhamento da cinética de reação das resinas preparadas, obtendo-se assim o seu grau de conversão e também uma análise da sua cinética de polimerização, sendo observado que em concentrações maiores de argila, o grau de conversão e a taxa de polimerização diminuíram. Por TGA foi possível observar dois picos no segundo processo de degradação térmica da amostra sem adição de argila, indicando uma polimerização não homogênea; conforme aumenta-se a quantidade de argila presente na mistura, os picos duplos tornam-se um. DMA mostrou discreto aumento da Tg e aumento de E\' e E\", indicando um reforço destes compósitos. DRX mostrou que não houve exfoliação da argila no polímero, podendo ter a formação de um compósito convencional ou de um compósito intercalado sem expansão do espaço interlamelar. Já os testes de inchamento mostraram que quanto maior o teor de argila maior a absorção de água das resinas. / In spite of the developments that led to the use of dental composites, there are still some shortcomings that limit their use. Inadequate resistance due to the mastigatory wearing is often cited as an issue in resins, which is partially responsible for reducing its lifetime. Wearing out of the material occurs by the loss or degradation of the organic matrix, thus allowing the inorganic matrix to become exposed and consequently leading to its loss. Therefore, the present work has as main goal the evaluation of the effect of different organoclay filler content in the properties of a experimental dental resin. For such, the clay was first purified and then underwent through cationic exchange, following preparation of the resins and later addition of the organoclay obtained and preparing the specimens. The, the resins were evaluated by techniques such as DMA, TGA, PCA, DRX and swelling tests to observe water sorption. By FTIR and PCA it was possible to follow the reaction kinectics of the prepared resins, thus obtaining the degree of convertion and polymerization rate, allowing to observe that the higher the organoclay loadings the lower was both the polymerization rate and the degree of convertion. TGA allowed us to observe two peaks on the second process of thermal degradation on the sample with no clay, thus indicating a non-homogeneous polymerization; and with higher clay loadings the double peaks become one single peak. DMA showed a slight increase of Tg and also an increase in E\' and E\", indicating a reinforcement of the obtained composites. DRX showed no exfoliation of the polymer, thus forming either a conventional composite or maybe a interlacated composite with no expansion of the interlamelar space. Swelling tests showed that the higher the amount of organoclay added the higher was the amount of water absorbed by the specimens.
10

Avaliação da resistência ao desgaste de uma resina composta odontológica nanoparticulada empregando diferentes tempos de fotopolimerização /

Souza, Celso Naves de. January 2009 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Edson Cocchieri Botelho / Banca: Carlos Roberto Grandini / Banca: Sandra Giacomin Schneider / Banca: Sergio Scheneider / Resumo: Este trabalho tem como objetivo avaliar a influência dos tempos de fotopolimerização nas resinas odontológicas, onde quatro resinas compostas foram utilizadas, sendo três micro híbridas e uma nanoparticulada. Esses compósitos foram submetidos ao desgaste abrasivo de esfera rotativa pelo método de ball cratering. Para tal ação foi projetado e construído um dispositivo de desgaste por micro abrasão de esfera rotativa livre de três corpos. Os corpos de prova foram confeccionados e embutidos em uma matriz de alumínio, com uma profundidade de 2mm. Usam-se o aparelho LED RADII, com os tempos de exposição de 20, 30 e 40 segundos e uma esfera com 15 mm de diâmetro de aço temperada, retificada e revenida. A lama abrasiva utilizada nesse estudo foi uma solução composta por 20% de talco (USP/200) e 80% de soro fisiológico, na quantidade de 3 gotas por segundo. Para comprovação dos resultados obtidos, utilizaram-se os testes de: Espectroscopia por Dispersão de Energia (EDS), Infravermelho por Transformada de Fourier (FT-IR), Análise Termogravimétrica (TGA), micro dureza Vickers, ensaio de desgaste de micro abrasão por esfera rotativa pelo método de ball cratering e a análise da superfície desgastada por Microscopia Eletrônica de Varredura (MEV). Esta análise foi realizada para verificar o real mecanismo de desgaste ocorrido. Os resultados obtidos comprovam que o tempo recomendado pelos fabricantes, tem a capacidade suficiente de fotopolimerizar toda a matriz orgânica, comprovaram também que a resina nanoparticulada obteve em todos os ensaios os melhores resultados em relação às resinas híbridas, e que a cultura do acréscimo de até 20s além do recomendado não tem influência direta em relação ao desgaste abrasivo. / Abstract: This work has as an objective to evaluate the influence of photopolymerization in odontological resins, where composed four resins were used, being three of them micro hybrid and one nanoparticulated. These composites were submitted to abrasive wear and tear of rotative sphere by the method ball cratering. For such action a device of micro abrasion of rotative sphere was designed and built free of three bodies. The bodies of proof were produced and put in a matrix of aluminum with a depth of 2mm. The device used was a LED RADII, with exposition time of 20, 30 and 40 seconds and a sphere of 15mm diameter made of tempered steel, rectified and soften, the abrasive lama used in this study was a solution composed by 20% of powder (USP/200) and 80% of physiological serum released at 3 drops per second. For verification of the results obtained the tests of Energy Dispersion Spectrograph (EDS) was used, transformed Infra red of Fourier (FT-IR), Thermogravimetric Analysis (TGA) Vickers micro hardness, wear and tear of micro abrasion by rotative sphere by the method ball cratering and the analysis of worn superficies by Sweeping Electronic Microscopy (SEM). This analysis was carried out to verify the real mechanism of the worn occurred. The results obtained prove that the time recommended by the manufacturer has enough capacity to photopolymerized all the organic matrix, it also proved that the resin nanoparticulated obtained in all the essays the best results in what concerns to the hybrid resins. And the culture of the addition of 20 seconds besides what is recommended has no direct influence in relation to the abrasive wear and tear. / Doutor