• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 5
  • 1
  • Tagged with
  • 42
  • 42
  • 34
  • 27
  • 27
  • 21
  • 19
  • 14
  • 13
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effects of denture cleansers on partial denture alloys and soft lining materials

Solovan, Donna F. January 1977 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1977. / Typescript (photocopy). Includes bibliographical references (leaves 59-61). Also issued in print.
2

Effects of denture cleansers on partial denture alloys and soft lining materials

Solovan, Donna F. January 1977 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1977. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 59-61).
3

Evaluation of an electro-sonic denture cleaner a thesis submitted in partial fulfillment ... denture prosthesis /

Muenchinger, Frederick S. January 1972 (has links)
Thesis (M.S.)--University of Michigan, 1972.
4

Evaluation of an electro-sonic denture cleaner a thesis submitted in partial fulfillment ... denture prosthesis /

Muenchinger, Frederick S. January 1972 (has links)
Thesis (M.S.)--University of Michigan, 1972.
5

Effect of denture cleanser on the surface roughness and hardness of denture base materials /

Tieng Chhnoeum, Nitipun Jeeraphaet, January 2008 (has links) (PDF)
Thesis (M.Sc. (Prosthodontics))--Mahidol University, 2008.
6

Avaliação in vitro da ação do hipoclorito de sódio e de pastilhas efervescentes quanto à alteração de cor em resinas acrílicas termopolimerizáveis e de microondas / In vitro evaluation of sodium hypochlorite and effervescent tablets actionregarding color alteration of heat and microwave-polymerized acrylic resins

Peracini, Amanda 10 July 2008 (has links)
O objetivo deste estudo foi avaliar a alteração de cor de resinas acrílicas termopolimerizáveis (convencional e de microondas) após imersões em soluções químicas higienizadoras de próteses totais em diferentes períodos de tempo. Foram obtidos padrões em cera (15mm de diâmetro e 4mm de espessura), a partir de uma matriz de teflon, que foram incluídos em muflas convencionais e para microondas. Após a eliminação da cera, as resinas foram manipuladas, prensadas e polimerizadas segundo as instruções dos fabricantes. Foram confeccionados 200 corpos-de-prova, 100 de cada marca comercial das resinas Lucitone 550 (L) e Onda Cryl (OC), os quais foram imersos nas soluções: A)Água destilada-3 min.; B)Bony Plus -3 min.; C)Água destilada-5 min.; D)Corega Tabs-5 min.; E)Água destilada-20 min.; F)Hipoclorito de sódio a 0,5%-20 min.; G)Hipoclorito de sódio a 1%-20 min.; H)Água destilada-8 horas; I)Hipoclorito de sódio a 0,5%-8 horas; J)Hipoclorito de sódio a 1%-8 horas. A alteração de cor foi avaliada empregando-se um espectrocolorímetro (Color Guide 45/0 BYK-Gardner) antes e após a simulação de 180 dias de imersão. Os resultados foram comparados por meio da análise de variância (ANOVA) para dois fatores, seguida pelo teste de Student-Newman Keuls, com nível de significância de 0,05. Para correlacionar as diferenças de cor para o ambiente clínico, os dados foram calculados de acordo com as unidades da National Bureau of Standards (NBS). Os resultados mostraram que a resina Lucitone 550 (ΔE = 0,47±0,18) apresentou-se mais estável que a Onda-Cryl (ΔE = 0,53±0,31). Para ambas as resinas, as pastilhas, os hipocloritos por 20 minutos (0,5% e 1%) e por 08 horas (0,5%) não provocaram alterações maiores que seus respectivos controles (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). As soluções de hipoclorito a 1% (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) causaram maiores alterações que seus respectivos controles. As soluções empregadas por 08 horas (água e Hipocloritos a 0,5% e 1%) provocaram alterações classificadas como leves, segundo o sistema NBS. Os achados deste estudo revelaram que as pastilhas efervescentes, quando usadas de acordo com as instruções dos fabricantes, e o hipoclorito de sódio (0,5% e 1%) por 20 minutos apresentaram menores valores de alteração de cor nas resinas acrílicas após um período de uso simulado de 180 dias. Médias mais elevadas foram obtidas quando um regime de 8 horas foi simulado. / The aim of this study was to evaluate color alteration of heat-polymerized acrylic resins (conventional and microwave-polymerized), after immersion in chemicals solutions of denture cleansers for different periods of time. Wax patterns were obtained (15 mm in diameter and 4 mm thickness) from a teflon matrix and were invested in metallic or microwavable flasks. The wax had been eliminated and the resins were mixed, packed and polymerized according to the manufacturers instructions. Two hundred specimens were made, 100 specimens of each commercial resin Lucitone 550 (L) e Onda Cryl (OC), which were immersed in the solutions: A)Distilled water-3 min.; B)Bony Plus-3 min.; C)Distilled water-5 min.; D)Corega Tabs-5 min.; E) Distilled water -20 min.; F) 0,5% Sodium Hypochlorite-20 min.; G) 1% Sodium Hypochlorite-20 min.; H)Distilled water-8 hours; I)0,5% Sodium Hypochlorite-8 hours; J)1% Sodium Hypochlorite -8 hours. Color alteration was assessed by a spectrocolorimeter (Color Guide 45/0 (BYKGardner) before and after 180 days simulation. The results were analyzed statistically by a two-way analysis of variance (ANOVA), and Student Newman-Keuls test, with significance level of 0.05. To relate the color differences to a clinical environment, the data were quantified by National Bureau of Standards (NBS) units. The results showed that the resin Lucitone 550 (ΔE=0,47±0,18) was more stable than the resin Onda-Cryl (ΔE=0,53±0,31). For both resins, the tablets, the hypochlorite by 20 minutes (0,5% e 1%) and by 8 hours (0,5%) did not produce higher alterations than the respective controls (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). The 1% hypochlorite solutions (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) produced higher alterations than the respective controls. The solutions employed by 8 hours (water and 0,5% and 1% hipochlorite) produced alterations classified as slight, according to the NBS system. The findings of this study showed that the effervescent tablets, used according to the manufacturer´s instructions, and the sodium hypochlorite (0,5% and 1%) used by 20 minutes presented lower values of color alterations in acrylic resins after a period of 180 days simulation. Higher mean averages were obtained when a period of 8 hours was simulated.
7

Avaliação da capacidade retentiva de sistema de encaixe o\'ring submetido a soluções de higienização diárias e à ciclagem mecânica / Evaluation of retention force of o\'ring overdenture system subjected to daily hygiene solutions and fatigue

Crizóstomo, Luciana Costa 10 December 2013 (has links)
A imersão de overdentures em soluções de higienização diárias associadas a constantes inserções e remoções podem comprometer seus componentes. Em função disso, o objetivo deste estudo foi avaliar a capacidade retentiva de o′rings (Conexão Sistemas de Prótese, Ltda) quando submetidos a imersões em soluções e ciclagem mecânica. Foram avaliadas as soluções: Cepacol (C), Cepacol Flúor (CF), Listerine (L), Hipoclorito de sódio 0,05% (HS) e água deionizada (AD), como controle positivo e a não imersão (SI), como controle negativo. Foi obtida uma base de nylon 6.6 contendo dois pilares o′ring, com plataforma protética (HI) de implantes e contra-bases com as cápsulas metálicas e anéis de nitrilo, que foram divididas em grupos (n = 6). Foram simulados 180 dias de imersão overnight e realizados 720 ciclos de inserção e remoção, com ensaios de fadiga. O valor da resistência à tração foi registrado a cada 30 dias e 120 ciclos, utilizando-se máquina de ensaios mecânicos, totalizando 7 leituras (T0, T1, T2, T3, T4, T5, T6). Os dados da capacidade retentiva (N) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados demonstraram diferenças significativas para o tempo (p= 0,0000) e para as soluções (p= 0,0000) e para a interação tempo X solução (p=0,0192). A capacidade retentiva no T0 (8,41 N) foi maior que no T1 (6,94 N), T2 (6,87 N), T3 (6,66 N), T4 (7,02 N), T5 (5,84 N) e T6 (5,02). Em relação às soluções, o HS propiciou obtenção de maior capacidade retentiva (8,37 N) que os demais grupos: AD (6,68 N), L (6,52 N), SI (6,43 N), CF (6,28 N) e C (5,77 N). Quanto às interações, a capacidade retentiva inicial de todos os grupos, com exceção do HS, foi maior que a final, entretanto é prematuro recomendá-lo para uso como higienizador. Desta forma, conclui-se que o Listerine, Cepacol e Cepacol Flúor apresentaram comportamentos semelhantes aos grupos controles, sendo, portanto, bem indicados como soluções para imersão de overdentures. / Denture cleansers associated with constant insertion and removal of overdentures may have deleterious effects on its components. Therefore, the aim of this study was to evaluate the effect of these solutions and fatigue strength on the retention loss of overdentures o´rings (Conexão Sistemas de Prótese, Ltda). Effect of 5 solutions were studied: Cepacol (C), Cepacol Flúor (CF), Listerine (L), 0,05% sodium hypochlorite (SH) and deionized water (DA, positive control) and without immersion (WI, negative control). Nylon 6.6 matrices containing 2 implants and abutments and acrylic specimens with the metal caps were obtained and divided in 6 groups (n=6). One hundred eighty days overnight soaks were simulated and 720 pulls were performed in fatigues test. The dislodging force was evaluated at baseline (T0) and after every 30 immersions and 120 pulls, using testing machine. There were performed 7 tests (T0, T1, T2, T3, T4, T5 e T6). The data were statistically analyzed by ANOVA and Bonferroni tests (α=0.05). The results were differents with time (p= 0.0000), solutions (p= 0.0000) and also interaction (p=0.0192). The retention T0 (8.41 N) was higher than T1 (6.94 N), T2 (6.87 N), T3 (6.66 N), T4 (7.02 N), T5 (5.84 N) and T6 (5.02). For solutions, the HS showed a higher mean (8.37 N), followed by AD (6.68 N), L (6.52 N), SI (6.43 N), CF (6.28 N), and C (5.77 N). Regarding interactions, the initial retention groups were higher than the final, with the exception of HS, however it is premature to recommend it for use as a cleanser. Thus, it can be concluded that Listerine, Cepacol, Cepacol Fluor behaved similarly to the control groups, and therefore well indicated as solutions for overdenture immersions.
8

Avaliação da perda de massa e alteração da rugosidade superficial causada pela associação dos métodos mecânico (escovação) e químico (imersão) de higiene de próteses totais / Evaluation of weight loss and surface roughness caused by the association of mechanical (brushing) and chemical (immersion) methods of denture cleanser.

Sorgini, Danilo Balero 18 November 2011 (has links)
O objetivo deste trabalho foi avaliar a perda de massa e a alteração da rugosidade superficial causadas pela associação dos métodos mecânico (escovação) e químico (imersão) de higiene de próteses totais. Foram utilizados 72 corpos de prova (90 x 30 x 3 mm) de Plexiglass. O ensaio de escovação (método mecânico) foi realizado em máquina de escovação (Mavtec), em frequência de 356 rpm, curso da escova (Tek Macia) de 3,8 centímetros, peso da sapata de 200 gramas e tempo de 50 minutos (simulação de 01 ano de escovação). Como suspensões, foram utilizadas água destilada e 04 dentifrícios (02 convencionais: Sorriso e Colgate; e 02 específicos para próteses totais: Polident e Corega). Após a escovação, os corpos de prova foram imersos (hipoclorito de sódio 0,5% - NaClO) por 121,6 horas (simulação de 01 ano de imersão, por 20 minutos diários). Foram obtidos 06 grupos, sendo 01 controle (C - escovação e imersão em água) e 05 experimentais (Ex1 - água; Ex2 - Sorriso; Ex3 - Colgate; Ex4 - Polident; Ex5 - Corega; todos imersos em NaClO). A perda de massa foi avaliada pelo método Gravimétrico, sendo as pesagens realizadas em balança (Metler Toledo GMbH) antes dos procedimentos de higiene (M1), após a escovação (M2) e após a imersão (M3). A alteração da rugosidade superficial (m) foi avaliada por rugosímetro (Surftest SJ-201P), por meio da obtenção de média de três leituras (4,0 mm de comprimento e valor de &Prime;cut-off&Prime; de 0,8 mm, a 0,5 mm/s) antes dos procedimentos de higiene (R1), após a escovação (R2) e após a imersão (R3). Os resultados foram submetidos a ANOVA (dois fatores) e teste de Bonferroni. Para a perda de massa, após o ensaio mecânico, entre os dentifrícios, os maiores valores foram registrados para Ex2 (-0,0137±0,0085), Ex3 (- 0,0123±0,0038) e Ex5 (-0,0121±0,0032), e menores para Ex4 (-0,0072±0,0017); após o método combinado, os maiores valores foram obtidos para os grupos Ex2 (-0,0184±0,0040) e Ex3 (- 0,0155±0,0034), e os menores para Ex4 (-0,0108±0,0023); o método combinado resultou em maior perda de massa que o método mecânico, exceto para o grupo Ex5. Para a alteração da rugosidade superficial, após o ensaio mecânico, os menores valores foram registrados para Ex1 (-0,007±0,016) e Ex4 (0,402±0,378) e maiores para os demais; após o método combinado, os maiores valores foram obtidos para Ex2 (1,617±1,190) e Ex5 (1,634±1,082), e os menores para Ex1 (-0,063±0,013); não houve diferença entre os tratamentos. Conclui-se que: 1. A escovação com dentifrícios acarretou maior perda de massa e alteração da rugosidade que a escovação com água; 2. A imersão em NaClO 0,5% associada à escovação com dentifrícios, acarretou maior perda de massa e alteração da rugosidade, quando comparada à imersão em água; 3. O dentifrício Polident (específico) apresentou os menores valores de perda de massa e de rugosidade superficial para ambos os métodos (mecânico e combinado); 4. O método combinado não resultou em alteração da rugosidade superficial, mas acarretou maior perda de massa que o método mecânico, exceto para o dentifrício Corega (específico). / The aim of this study was evaluate the weight loss and changes in surface roughness when mechanical and chemical methods of denture cleanser were associated. Seventy-two Plexiglass specimens (90x30x3 mm) were used. The brushing test was carried out using a toothbrushing machine (Mavtec), with a frequency of 356 rpm, course covered by brush corresponds to 3.8 cm, the load was standardized at 200 g, and length of 50 minutes (01 year of brushing). Like suspension, were utilized distilled water and 04 dentifrices (02 conventional: Sorriso and Colgate; and 02 indicated for denture cleanser: Polident and Corega). After brushing, the specimens were immersed in sodium hypochlorite (NaClO) 0,5% for 121,6 hours (01 year of immersion). Six groups were obtained, 01 control (C - brushing and immersion with water) and 05 experimental (Ex1: water; Ex2: Sorriso; Ex3: Colgate; Ex4: Polident; Ex5: Corega- all immersed in NaClO). The specimens were weighed before the tests (M1), after the brushing test (M2) and after the immersion test (M3) in a precision balance (Metler Toledo GMbH). The surface roughness (m) was evaluated by rugosimeter (Surftest SJ-201P) before the tests (R1), after the brushing test (R2) and after the immersion test (R3). The weight loss and roughness dates were subjected to ANOVA and Bonferroni tests (p < 0.05). After the brushing test, between the dentifrices, the greater values was registered for Ex2 (-0,0137±0,0085), Ex3 (-0,0123±0,0038) e Ex5 (-0,0121±0,0032), and the lowest for Ex4 (-0,0072±0,0017); after the association of the two methods, the grater values was obtained for Ex2 (-0,0184±0,0040) e Ex3 (-0,0155±0,0034), and the lowest for Ex4 (- 0,0108±0,0023); the association of the methods resulted in greater weight loss than the mechanical method, except for Ex5. For the surface roughness, after the mechanical test, the lowest values were registered for Ex1 (-0,007±0,016) and Ex4 (0,402±0,378), and the grater for the others; after the association of the methods, the greater values were obtained for Ex2 (1,617±1,190) and Ex5 (1,634±1,082), and the lowest for Ex1 (-0,063±0,013); there was no difference for the treatments. We conclude that: 1. Brushing with toothpaste resulted in greater weight loss and change in roughness that brushing with water. 2. The immersion in NaClO 0.5% associated with tooth brushing caused greater weight loss and change of roughness, when compared to immersion in water. 3. The toothpaste Polident (specific) had the lowest mass loss and surface roughness for both methods (mechanical and combined) 4. The association of the two methods resulted in no change in surface roughness, but in greater weight loss than the mechanical method, except for the Corega (specific).
9

Avaliação clínica e laboratorial de uma solução experimental à base de Ricinus communis em comparação ao hipoclorito de sódio para higiene de próteses totais / Clinical and laboratorial evaluation of an experimental solution based on Ricinus communis compared to sodium hypochlorite for denture cleansing

Badaró, Mauricio Malheiros 06 December 2013 (has links)
Este estudo clínico-laboratorial avaliou uma solução à base de Ricinus communis para higiene de próteses totais, comparando-a ao hipoclorito de sódio, quanto à efetividade na remoção do biofilme, remissão de Candidíase Atrófica Crônica, grau de satisfação dos pacientes e rugosidade superficial da resina acrílica termopolimerizada. Sessenta e quatro usuários de próteses totais com ausência (n=40) ou presença de Candidíase (n=24) foram selecionados e orientados a escovar as próteses com escova específica e sabão neutro por 3 minutos, 3 vezes ao dia e imergi-las nas soluções de higiene (Hipoclorito de sódio 0,25% - S1; e 0,5% - S2; R. communisa 10% - S3; Salina - S4: controle) por 20 minutos. As soluções foram utilizadas de forma cruzada e randomizada com períodos de \"wash out\". Para quantificação do biofilme (ImageTool 3.0), a superfície interna foi evidenciada (vermelho neutro 1%) e fotografada ao final de cada período. A remissão da Candidíase foi avaliada por atribuição de escores antes e após o uso das soluções. A satisfação dos pacientes foi analisada por questionário. A rugosidade da superfície polida e não polida de 40 espécimes (90x30x4mm) de resina foi avaliada antes e após a exposição dos mesmos ao protocolo clínico de higiene por meio de rugosímetro e Microscopia Eletrônica de Varredura. A remoção do biofilme foi analisada como um \"split-plot\" com dois fatores de variação: presença de inflamação e soluções. A remissão da Candidíase foi analisada após ajuste dos dados por regressão logística multinomial. Para análise da satisfação dos pacientes os dados foram ajustados por regressões logísticas e foi adotada análise de simetria composta. Para avaliação da rugosidade das superfícies polida e não polida foi empregada análise de variância com dois fatores (período e solução). Todas as análises foram realizadas com nível de significância de 5%. Não houve diferença na porcentagem de biofilme entre pacientes com e sem inflamação, bem como na interação entre os fatores. Houve diferença entre soluções, sendo que o Hipoclorito de sódio a 0,25 e 0,5% promoveu as menores médias de biofilme (4,41±7,98 e 2,93±5,23), seguido do R. communis(6,95±10,93) e Salina (11,07±11,99). Para remissão da Candidíase, as soluções mais eficientes foram R. communis(50%) e Hipoclorito de sódio 0,25% (46%). O questionário de satisfação não indicou diferença entre as soluções. A rugosidade da superfície polida não foi alterada pelo período (p=0,062). Houve alteração em função das soluções (p=0,00) e da interação entre os fatores (p=0,005). Para S1 e S4, o período não influenciou na rugosidade. Para S2, houve alteração a partir de 07 dias, permanecendo estável após 14 dias. Para S3, houve alteração e estabilização a partir de 14 dias. Após 07 e 14 dias, S2 e S3 promoveram as maiores alterações, porém após 21 dias, não houve diferença entre as soluções, exceto a salina. A superfície não polida não foi influenciada pelos fatores período (p=0,358), solução (p=0,120) e interação (p=0,204). Concluiu-se que há viabilidade do uso do hipoclorito de sódio em menores concentrações e do Ricinus communis para remoção do biofilme, remissão da Candidíase e controle da rugosidade superficial. / This clinical-laboratory study evaluated a solution based on Ricinus communis for denture cleansing, comparing it to sodium hypochlorite, regarding biofilm removal capacity, remission of atrophic chronic candidiasis, degree of patient satisfaction and surface roughness of heat-polymerized acrylic resin. Sixty-four denture wearers with absence (n = 40) or presence of Candidiasis (n = 24) were selected and oriented on how to brush their dentures with a specific brush and mild soap for 3 minutes, 3 times a day and immerse them in hygiene solutions (0.25% sodium Hypochlorite - S1 and 0.5% - S2, R. communis 10% - S3; Saline - S4: control) for 20 minutes. The solutions were used in a randomized and cross form with \"washout\" periods. To quantify biofilm (ImageTool 3.0), the inner surface was disclosed (1% neutral red) and photographed at the end of each period. The remission of Candidiasis was assessed by assigning scores before and after using solutions. Patient satisfaction was assessed by questionnaire. The surface roughness of 40 polished and unpolished resin specimens (90x30x4mm) was evaluated before and after their exposure to clinical protocol hygiene by surface roughness and scanning electron microscopy. The biofilm removal was analyzed as a \"split-plot\" with two variation factors: inflammation and solutions. The candidiasis remission was analyzed after adjustment using multinomial logistic regression. For patient satisfaction logistic regression analysis was adopted and compound symmetry. For evaluation of surface roughness polished and unpolished was employed analysis of variance with two factors (time and solution). All the analysis were performed with a significance level of 5 %. There was no difference in the percentage of biofilm between patients with and without inflammation, as well as the interaction between the factors. There were differences among the solutions, having the Sodium Hypochlorite 0.25 % and 0.5% promoted the lowest average biofilm (4.41±7.98 and 2.93±5.23), followed by R. communis (6.95±10.93) and Saline (11.07±11.99) . For the remission of candidiasis, the most efficient solutions were R. communis (50%) and 0.25% sodium hypochlorite (46%). The satisfaction questionnaire indicated no difference among the solutions. The roughness of the polished surface was not affected by time (p = 0.062). There was a change in function of the solutions (p = 0.00) and the interaction between factors (p = 0.005). For S1 and S4, the period did not influence the roughness. For S2, there was a change from 07 days, remaining stable after 14 days. For S3, there were changes and stabilization from 14 days. After 7 and 14 days, S2 and S3 promoted major changes, but after 21 days, there were no difference among the solutions except the saline. The unpolished surface is not influenced by factors: period (p = 0.358), solution (p = 0.120) and interaction (p = 0.204). It was concluded that there is feasibility for using sodium hypochlorite at lower concentrations and Ricinus communis for the removal of biofilm, remission of candidiasis and control of surface roughness.
10

Avaliação clínica da eficácia dos métodos químico (peróxido alcalino) e mecânico (ultra-som) frente à propriedade de remoção do biofilme de próteses totais / Clinical evaluation of the efficacy on biofilm removal from complete denture of the chemical (alkaline peroxide) and mecanical (ultrasonic) methods

Cruz, Patricia Costa 07 November 2007 (has links)
O objetivo deste trabalho foi avaliar clinicamente a capacidade de remoção do biofilme da prótese total dos métodos de higiene: químico (pastilha efervescente para imersão de próteses totais à base de peróxido alcalino), mecânico (aparelho ultra-sônico), e associado (pastilha efervescente + aparelho ultra-sônico). Oitenta pacientes (usuários de próteses totais superiores e inferiores) participaram de um período experimental de 21 dias e foram distribuídos em 4 grupos (n=20): 1) Controle - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água; 2) Químico - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água e imersão em recipiente contendo ½ copo de água morna e 01 pastilha efervescente Corega Tabs por 5 minutos; 3) Mecânico - escovação das próteses com escova específica (Bitufo) 3 vezes ao dia (após café da manhã, almoço e jantar) com água, e uma única agitação ultra-sônica por 15 minutos ao final do período experimental (21 dias); 4) Associado - associação dos métodos 2 e 3. Para a quantificação do biofilme, as superfícies internas das próteses totais superiores foram evidenciadas (vermelho neutro 1%), fotografadas em 45º (Canon EOS Digital Rebel), processadas (Adobe Photoshop 5.0) e as áreas (total da superfície interna e corada com biofilme) quantificadas (Image Tool 2.02). A porcentagem do biofilme foi calculada como a relação entre a área do biofilme multiplicado por 100 e a área da superfície total da base interna da prótese. Os resultados mostraram diferenças entre os métodos (teste de Kruskal-Wallis, significância de 0,05), com superioridade dos métodos químico (37.2), mecânico (35.2) e associado (29.1) sobre o controle (60.5). Como conclusão, a imersão em peróxido alcalino e o uso do ultra-som podem ser empregados como agentes auxiliares na higienização de próteses totais. / The aim of this study was to evaluate the hability of the biofilm removal from complete denture of the chemical (alkaline peroxide-effervescent tablets to complete denture immersion), mechanical (ultrasonic) and combined (association of the effervescent and ultrasonical methods) methods. Eighty patients that use upper and lower complete denture participated of the experimental period of 21 days and they were distibuted in 4 groups (n=20): 1) Control - brushing the dentures with especifc brush (Bitufo), 3 times a day (after breakfast, lunch and dinner) with water; 2) Chemical - brushing the dentures with especifc brush (Bitufo), 3 times per day (after breakfast, lunch and dinner) with water and immersion in a recipient containing warm water and 01 effervescent tablet of Corega Tabs for 5 minutes; 3) Mechanical - brushing the dentures with especific brush (Bitufo), 3 times a day (after breakfast, lunch and dinner) with water and only one ultrasonic vibration per 15 minutes in the end of the esperimental period (21 days); 4) Combined - association of the methods 2 and 3. To quantify the biofilm, the internal surfaces of the upper complete dentures were stained and photographed in 45º (Canon EOS Digital Rebel), processed (Adobe Photoshop 5.0) and the areas (total internal surface and stained with biofilm) quantified (Image Tool 2.02). The percentage of the biofilm was calculated by the relation between biofilm area multiplier by 100 and total area of the internal surface of the upper complete denture. The results showed diferences between the methods (teste de Kruskal-Wallis, significância de 0,05), with superiority of the chemical (37.2), mechanical (35.2) and combined (29.1) methods above control group (60.5). As conclusion, the immersion with alkaline peroxide and the use of ultrasonic vibration can be employed as auxiliary agents on the hygiene of complete dentures.

Page generated in 0.0549 seconds