Influência do sistema de aterramento na presença de distorção harmônica / Influence of the grounding system in the presence of harmonic distortion

Gamito, Marcos Aparecido Ruiz 13 October 2016 (has links)
Com o surgimento das novas tecnologias aplicadas aos equipamentos e arranjos geométricos das fontes renováveis de energia, o sistema de aterramento passou a operar com correntes de várias frequências, diferentes da componente fundamental. Estas correntes são provenientes das novas cargas não lineares conectadas e das condições de falta, tornando mais difícil a equipotencialização do sistema de aterramento, devido, principalmente, ao seu tamanho e sua geometria. Neste cenário, esta pesquisa tem como objetivo o estudo do comportamento de um sistema de aterramento operando na presença de correntes com distorção harmônica. Para a modelagem do sistema de aterramento teste, foi utilizada a teoria de linhas de transmissão, considerando parâmetros distribuídos, pela qual o condutor foi modelado em porções ao longo de seu comprimento. Para a modelagem e análise do sistema de aterramento foram utilizados o programa ATP (Alternative Transients Program) e uma ferramenta computacional comercial, com o intuito de validar os valores da resistência da malha de aterramento observados. Pelos resultados encontrados, têm-se argumentos para alertar os projetos futuros de sistemas de aterramento para a necessidade e uma melhor análise das situações operacionais passíveis de ocorrência no sistema elétrico que venham a apresentar uma composição harmônica diferente e não desprezível em relação ao componente fundamental. / With the rise of new technology applied to devices and geometric arrangements related to renewable energy sources, grounding systems have started to operate with currents of multiple frequencies, deviating from its fundamental component. These currents come from the connection of new nonlinear loads and fault conditions, which makes the equipotential bonding harder for the grounding system, mainly due to its size and geometry. In this scenario, this research aims to study the behavior of a grounding system operating in the presence of harmonically distorted currents. The transmission line theory was used to model the testing grounding system, based on distributed parameters, through which the conductor was modeled in increments along its length. For modeling and studying the grounding system, the ATP (Alternative Transients Program) and a commercial software tool were used in order to validate the resistance values observed in the grounding grid. Based on the results found, there are arguments to alert future grounding system projects about the need for a better assessment of operational scenarios likely to occur in the electrical system, which may display a different harmonic composition that is not negligible in relation to the fundamental component.
2

Previsão de distorção harmônica em cargas residenciais utilizando redes neuro-fuzzy / Prediction of harmonic distortion in residential loads using neurofuzzy networks

MORAIS JÚNIOR, Albino Moisés Faro de 11 July 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-10-01T14:39:49Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-10-01T14:40:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) / Made available in DSpace on 2018-10-01T14:40:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) Previous issue date: 2018-07-11 / Este trabalho apresenta uma modelagem para DHTv%, DHTi% e harmônicos individuais utilizando previsões de um sistema ANFIS que aprende com dados medidos e prevê o comportamento da rede para valores futuros. Estas previsões podem ajudar a atender as normas nacionais de DHTv% estipuladas pela Agência Nacional de Energia Elétrica (ANEEL) através dos Procedimentos de Distribuição (PRODIST), como as normas internacionais de DHTi%., desta forma se antecipando às normas que atualmente são recomendativas, mas em um futuro próximo serão punitivas. A modelagem é realizada por meio de um sistema Neuro-Fuzzy denominado ANFIS, o qual utiliza rede neural para aprender o comportamento do sistema e ajuste dos parâmetros e regra Fuzzy para a determinação dos valores de saída do sistema levando em consideração o aprendizado da rede Neural. A grande vantagem desta ferramenta é o poder de se modelar padrões utilizando uma previsão de estado harmônico das cargas conectadas na baixa tensão, o que ajuda na criação de pseudomedidas para as redes de distribuição, onde é difícil e oneroso a obtenção de medições reais. Entre as aplicações práticas para esta ferramenta pode-se destacar a utilização dos valores previstos em substituição a valores anômalos medidos, a utilização em medidores de energia para prever e evitar a ultrapassagem dos valores de Distorção Harmônico estipulados em norma e a utilização como base para a previsão de harmônicas individuais, que podem ser utilizadas em estudos de fluxo de carga harmônicos. / This work presents a modeling for THDv%, THDi% and individual harmonics using predictions from an ANFIS system that learns with measured data and predicts the behavior of the network for future values. These forecasts can help meet national THDv% standards stipulated by the Agência Nacional de Energia Elétrica (ANEEL) through Distribution Procedures (PRODIST), such as THDi% international standards, thus anticipating the currently recommended standards, but in the near future will be punitive. The modeling is performed by means of a Neuro-Fuzzy system called ANFIS, which uses neural network to learn the behavior of the system and adjustment of the parameters and Fuzzy rule for the determination of the system output values taking into account the learning of the Neural network. The great advantage of this tool is the power of modeling standards using a prediction of the harmonic state of the connected loads in the low voltage, which helps in the creation of pseudomedidas for the distribution networks, where it is difficult and costly to obtain real measurements. Among the practical applications for this tool is the use of the predicted values instead of measured anomalous values, the use in energy meters to predict and avoid exceeding the values of Harmonic Distortion stipulated in standard and the use as a basis for the prediction of individual harmonics that can be used in harmonic load flow studies.
3

Influência do sistema de aterramento na presença de distorção harmônica / Influence of the grounding system in the presence of harmonic distortion

Marcos Aparecido Ruiz Gamito 13 October 2016 (has links)
Com o surgimento das novas tecnologias aplicadas aos equipamentos e arranjos geométricos das fontes renováveis de energia, o sistema de aterramento passou a operar com correntes de várias frequências, diferentes da componente fundamental. Estas correntes são provenientes das novas cargas não lineares conectadas e das condições de falta, tornando mais difícil a equipotencialização do sistema de aterramento, devido, principalmente, ao seu tamanho e sua geometria. Neste cenário, esta pesquisa tem como objetivo o estudo do comportamento de um sistema de aterramento operando na presença de correntes com distorção harmônica. Para a modelagem do sistema de aterramento teste, foi utilizada a teoria de linhas de transmissão, considerando parâmetros distribuídos, pela qual o condutor foi modelado em porções ao longo de seu comprimento. Para a modelagem e análise do sistema de aterramento foram utilizados o programa ATP (Alternative Transients Program) e uma ferramenta computacional comercial, com o intuito de validar os valores da resistência da malha de aterramento observados. Pelos resultados encontrados, têm-se argumentos para alertar os projetos futuros de sistemas de aterramento para a necessidade e uma melhor análise das situações operacionais passíveis de ocorrência no sistema elétrico que venham a apresentar uma composição harmônica diferente e não desprezível em relação ao componente fundamental. / With the rise of new technology applied to devices and geometric arrangements related to renewable energy sources, grounding systems have started to operate with currents of multiple frequencies, deviating from its fundamental component. These currents come from the connection of new nonlinear loads and fault conditions, which makes the equipotential bonding harder for the grounding system, mainly due to its size and geometry. In this scenario, this research aims to study the behavior of a grounding system operating in the presence of harmonically distorted currents. The transmission line theory was used to model the testing grounding system, based on distributed parameters, through which the conductor was modeled in increments along its length. For modeling and studying the grounding system, the ATP (Alternative Transients Program) and a commercial software tool were used in order to validate the resistance values observed in the grounding grid. Based on the results found, there are arguments to alert future grounding system projects about the need for a better assessment of operational scenarios likely to occur in the electrical system, which may display a different harmonic composition that is not negligible in relation to the fundamental component.
4

Estimação da contribuição de múltiplas fontes harmônicas utilizando regressão não paramétrica

SOARES, Thiago Mota 22 March 2012 (has links)
Submitted by Samira Prince (prince@ufpa.br) on 2012-10-10T13:54:16Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstimacaoContribuicaoMultiplas.pdf: 2448614 bytes, checksum: 1a6b2ae9358b9b2d5f16dbc9abdca046 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2012-10-10T15:52:28Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstimacaoContribuicaoMultiplas.pdf: 2448614 bytes, checksum: 1a6b2ae9358b9b2d5f16dbc9abdca046 (MD5) / Made available in DSpace on 2012-10-10T15:52:28Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstimacaoContribuicaoMultiplas.pdf: 2448614 bytes, checksum: 1a6b2ae9358b9b2d5f16dbc9abdca046 (MD5) Previous issue date: 2012 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma nova metodologia para estimar a contribuição harmônica de múltiplas cargas geradoras de harmônicos na distorção de tensão de um sistema elétrico. Essa metodologia cria modelos estatísticos que descrevem o comportamento da tensão harmônica de um sistema elétrico qualquer em função da corrente harmônica das cargas presentes nele, de tal forma, que seja possível avaliar o impacto das cargas geradoras de harmônicos nos níveis de distorção harmônica de tensão do sistema elétrico em análise. A criação desses modelos é realizada com base no método estatístico chamado de regressão polinomial local de kernel, que é um método de regressão não paramétrica, cuja característica principal é criar modelos não condicionados a uma família específica de curvas de regressão, ou seja, os dados são os únicos responsáveis pelo formato do modelo. Uma vez criado o modelo, estima-se a tensão harmônica que as cargas provocaram no período em análise e, por fim, avalia-se seu valor em relação à medida. / This paper presents a new methodology for estimating the contribution of multiple harmonic-producing loads in the voltage harmonic distortion in an electrical system. This method creates statistical models that describe the behavior of the harmonic voltage of an electrical system in function of the harmonic current of the loads present in the system so that it is possible to evaluate the impact of harmonic-producing loads in the levels of harmonic voltage in the electrical system under consideration. The creation of these models is performed based on the statistical method called local polynomial kernel regression, which is a nonparametric regression method, whose main feature is to create models not conditional on a specific family of regression curves, that is, data are solely responsible for the shape of the model. Once the model is created, it is estimated the harmonic voltage caused by the loads in the period under consideration, and, finally, this voltage is evaluated in relation to the harmonic voltage measured.