• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 337
  • 20
  • 4
  • Tagged with
  • 361
  • 361
  • 289
  • 238
  • 155
  • 140
  • 92
  • 88
  • 88
  • 57
  • 57
  • 54
  • 52
  • 50
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Consumo de energia elétrica das exportações brasileiras por área de concessão de distribuição / Electricity consumption of Brazilian exports by distribution area

Maria Carolina Correia Marques 29 November 2012 (has links)
Este trabalho tem como objetivo analisar a composição setorial do consumo de energia elétrica incorporado às exportações brasileiras em cada área de concessão de distribuição. Para tanto, foi elaborada uma matriz de insumo-produto inter-regional e coeficientes setoriais de consumo de energia elétrica por área de concessão. Foi constatado que o consumo de energia elétrica incorporado às exportações é maior nos setores industriais e que a produção destinada à exportação é mais eletrointensiva que a produção destinada ao consumo interno em 37 das 58 áreas de concessão analisadas. / The objective of this dissertation is to analyze the sectorial composition of the electric energy consumption used in the production of exported goods and services in each electricity distribution concession area in Brazil. To accomplish this goal, an input-output matrix was elaborated, along with sectorial coefficients of electric energy intensity. The results indicate that the sector which consumes the most energy in their exports is the industrial sector. There was also an indication that Brazilian exports consume more electric energy throughout their productive structure than the production absorbed internally in 37 of the 58 electricity distribution concession areas.
132

ALOCAÇÃO ÓTIMA DE CAPACITORES EM SISTEMAS DE DISTRIBUIÇÃO RADIAL, UTILIZANDO-SE ESTRATÉGIAS EVOLUTIVAS / EXCELLENT ALLOCATION OF CAPACITORS IN SYSTEMS OF RADIAL DISTRIBUTION, USING EVOLUTION STRATEGIES

Petinelli, Airton Egydio 29 May 2002 (has links)
Made available in DSpace on 2016-08-17T14:52:42Z (GMT). No. of bitstreams: 1 Airton Petinelli.pdf: 783096 bytes, checksum: 283e35e9f4e3e61ee0abe5860d9dcb08 (MD5) Previous issue date: 2002-05-29 / Static reactive power sources, such as shunt capacitors, have been commonly used to provide reactive compensation in distribution systems, minimizing losses and keeping voltage levels within operational limits. Heuristic algorithms for capacitor placement have been proposed in several works. However, the majority of these approaches converge to a local solution. This dissertation presents a hierarchical evolution strategy-based approach for solving the optimal reactive sources placement in radial distribution systems. The approach is based on the (m+l)-EE paradigm, improved by mutations control and by two types of mutations: the classical Gaussian mutation and the Cauchy-based mutation. Discrete standard capacitor values with non-linear cost are considered. Constraints such as the maximum number of parallel banks and installations cost are included. Validation tests have been performed using a real industrial feeder. / Fontes estáticas de potência reativa, tais como os capacitores, têm sido comumente usados para a compensação de potência reativa em sistemas de distribuição de energia elétrica. Capacitores são instalados para minimizar as perdas de potência e manter os níveis de tensão dentro de limites operacionais aceitáveis. Algoritmos heurísticos têm sido propostos na literatura para a alocação de capacitores, entretanto, a maioria deles converge para uma solução local. Nesta dissertação, é apresentado um algoritmo hierárquico utilizando uma estratégia evolutiva para solucionar a alocação ótima de fontes de reativos em sistemas de distribuição radiais. O enfoque é baseado no paradigma (m+l)-EE, melhorado pelo controle de mutação com a utilização de dois tipos: a mutação clássica de Gauss e a mutação de Cauchy. Considera-se também a discretização de banco de capacitores com a utilização de tamanho de células disponíveis comercialmente e respectivos custos de aquisição, assim como restrições do tipo número máximo de capacitores em paralelo e custos de instalação. O algoritmo é testado usando-se um alimentador industrial da Companhia Energética do Maranhão - CEMAR
133

Aplicação de algoritmos e evolutivos para a otimização do fluxo de potência em sistemas de subtransmissão de energia elétrica. / Evolutionary algorithms applied for power flow optimization on subtransmission electric systems.

Danilo Belpiede 17 November 2006 (has links)
Esta dissertação apresenta uma metodologia de otimização do fluxo de potência em sistemas elétricos de subtransmissão utilizando duas técnicas da Computação Evolutiva, os Algoritmos Genéticos e as Estratégias Evolutivas. A metodologia decompõe o problema em duas partes e o trata seqüencialmente. A primeira parte procede com a otimização do fluxo de potência ativa e a segunda com a otimização do fluxo de potência reativa. São apresentadas as características e estruturas básicas dos Algoritmos Genéticos e das Estratégias Evolutivas. A técnica dos Algoritmos Genéticos é implementada no modelo de otimização do fluxo de potência ativa e a técnica das Estratégias Evolutivas no modelo de otimização do fluxo de potência reativa. As variáveis de controle dos modelos desenvolvidos são, respectivamente, os estados dos dispositivos de seccionamento e os níveis de tensão dos barramentos dos pontos de fronteira, associadas ao sistema analisado. Analisam-se os sistemas elétricos de subtransmissão que contêm múltiplos pontos de fronteira (conexão) com a Rede Básica e diversas possibilidades de configuração operativa. A metodologia proposta é aplicada a um sistema elétrico de subtransmissão real a fim de minimizar o custo dos encargos de uso dos sistemas de transmissão. Os resultados obtidos mostram a eficácia dos algoritmos desenvolvidos na busca das soluções desejadas. / This dissertation presents a power flow optimization methodology on subtransmission electric systems using two techniques of Evolutionary Computation, namely the Genetic Algorithms and the Evolution Strategies. The methodology splits the problem into two parts and treats it separately. On the first step it proceeds to optimize the active power flow and on the second step to optimize the reactive power flow. Characteristics and basic structures of the Genetic Algorithms and the Evolution Strategies are shown. The Genetic Algorithms technique is implemented on the active power flow optimization model and the Evolution Strategies technique on the reactive power flow optimization model. The control variables of developed models are, respectively, the switch states and the border point bar voltage levels, associated to the analyzed system. The subtransmission electric systems that have multiple border (connection) points to the Basic Network and many operative configuration possibilities are analyzed. The proposed methodology is applied to a real subtransmission electric system in order to minimizes the transmission system use duty costs. The obtained results show the efficacy of the developed algorithms in the search of desired solutions.
134

Itens regulatórios: um estudo aplicado à regulamentação tarifária da energia elétrica no Brasil / Regulatory items: a study applied to the Brazilian electricity tariff regulation

Gustavo Raldi Tancini 02 September 2013 (has links)
As empresas com tarifas reguladas, de maneira geral, fornecem bens públicos. Muitas delas atuam em atividades que são prerrogativas, diretas ou indiretas, do estado. A regulamentação tarifária se justifica pelo fato de essas empresas não atuarem em condições de mercado. A tarifa é definida de maneira a fornecer uma remuneração justa, pelo risco assumido pelo investidor e, concomitantemente, um custo razoável para os consumidores. Existem dois modelos extremos de regime tarifário: cost-plus (pelo custo) ou fixed-price (pelo preço). O primeiro repassa todos os custos incorridos e mais uma margem às tarifas. Por outro lado, os regimes pelo preço fixam a tarifa máxima, que não está necessariamente associada aos custos incorridos. A diferença fundamental entre os dois regimes está no estímulo à eficiência, inexistente nos regimes pelo custo. Na prática, muitos regimes são considerados como híbridos, ou seja, somente alguns custos têm sua recuperação garantida. Nesses regimes, é necessária a existência de algum mecanismo de repasse dos custos recuperáveis. No Brasil, o setor elétrico adotou um modelo no qual a tarifa garante a recuperação dos custos não gerenciáveis (a chamada \"parcela A\"), e os custos gerenciáveis são fixados com base em níveis considerados como eficientes (a chamada \"parcela B\"). Por meio da portaria interministerial MF/MME nº 025/2002, o poder concedente cria um mecanismo para garantir a recuperação dos custos não gerenciáveis - a chamada conta de Compensação da Variação dos Custos da Parcela A (CVA). Segundo esse mecanismo, a diferença entre os custos que compõem essa parcela e o efetivamente incorrido é repassada no próximo reajuste tarifário anual. Caso o saldo não seja integralmente recuperado dentro de um ano, o resíduo é contemplado nos próximos reajustes anuais. O saldo da CVA é atualizado pela SELIC, da data de sua ocorrência até a data de sua liquidação. Com a adoção das normas internacionais de contabilidade, os itens regulatórios foram eliminados das demonstrações contábeis societárias. Devido às suas funções regulatórias, a agência nacional de energia elétrica (ANEEL) decidiu criar a contabilidade regulatória, na qual, entre outras exigências, o reconhecimento da CVA é obrigatório. O presente estudo analisa se a regulamentação tarifária fornece suporte para o reconhecimento contábil dos itens regulatórios, bem como, especificamente o da CVA. O estudo se suporta pela teoria da regulação e pela teoria contábil, com ênfase na estrutura conceitual para elaboração e divulgação de relatório contábil-financeiro (IFRS FOUNDATION, 2010). A pesquisa pode ser rotulada como qualitativa. Conclui-se que os itens regulatórios somente podem ser reconhecidos quando existe um recurso econômico ou uma obrigação econômica presente. Por consequência, apenas devem ser contabilizados os itens regulatórios cuja recuperação ou devolução for garantida. Especificamente para a CVA, não existem evidências objetivas de que seu saldo possa ser recuperado de outra maneira que não seja pela tarifa de fornecimento de energia, não devendo, portanto, ser reconhecido nas demonstrações contábeis societárias. / Rate-regulated companies generally provide public goods. Many of them carry out activities that are prerogative, direct or indirect, of the State. Rate regulations are justified by the fact that these companies do not operate under free market conditions. Rates are set in order to provide a fair return to the risk taken by the investor and concomitantly a reasonable cost to consumers. There are two broad regulatory regimes: cost-plus and fixed-prices. Regimes based on cost allow the recovery of all incurred costs, plus a margin. On the other hand, regimes based on price set a maximum rate, which is not necessarily associated with the incurred costs. The key difference between regimes is the efficiency stimulus, not present in cost regimes. In practice, many regimes are considered hybrid, in other words, just some costs have their recovery guaranteed. Under these regimes, it is necessary a pass-through mechanism for the recoverable costs. In Brazil, the energy sector adopted a model in which the rate allows the recovery of non-manageable cost (called \"Parcel A\"), while manageable costs are recovered based on efficiency levels (called \"Parcel B\"). Through the Portaria Interministerial MF/MME no 025/2005, the grantor creates a mechanism that allows the recovery of non-manageable costs, the so-called \"Conta de Compensação de Variação dos Custos da Parcela A (CVA). By this mechanism, the difference between the costs that are included in \"Parcel A\" and those actually incurred is considered in the next annual rate reset. In the case that it is not wholly recovered within one year, the remainder will be contemplating in the next annual rate resets. The CVA balance is indexed by the SELIC from the date of its occurrence to its settlement. With the International Accounting Standards adoption, the regulatory items are derecognized from the corporate financial statements. Due to its regulatory duties, ANEEL decided to create the Regulatory Accounting, in which amongst other requirements, the recognition of the regulatory items is mandatory. The present study analyses if the rate regulation provides support for the recognition of regulatory items, more specifically, the CVA. The study is based on the Regulation Theory and Accounting Theory with emphasis in the Conceptual Framework for Financial Reporting (IFRS FOUNDATION, 2010). The research can be labelled as qualitative. It was concluded that regulatory items shall only be recognized when there are a present economic resource or a present economic obligation. Consequently, only the regulatory items which the recovery or the devolution is guaranteed can be booked. Specifically for CVA, there are no objective evidences that its balance can be recovery by other mean different than energy supply rate. Therefore, it shall not be recognized in the corporate financial statements.
135

Planejamento de bancos de baterias em sistemas de distribuição de energia

Santos, André Lopes Marinho dos 26 February 2018 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-05-23T17:48:25Z No. of bitstreams: 1 andrelopesmarinhodossantos.pdf: 2400435 bytes, checksum: 2f58d7bcbbafebad1c3f9814b3568a23 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-05-24T17:37:03Z (GMT) No. of bitstreams: 1 andrelopesmarinhodossantos.pdf: 2400435 bytes, checksum: 2f58d7bcbbafebad1c3f9814b3568a23 (MD5) / Made available in DSpace on 2018-05-24T17:37:03Z (GMT). No. of bitstreams: 1 andrelopesmarinhodossantos.pdf: 2400435 bytes, checksum: 2f58d7bcbbafebad1c3f9814b3568a23 (MD5) Previous issue date: 2018-02-26 / O presente trabalho apresenta uma metodologia para o planejamento da operação de bancos de baterias em redes de distribuição, as quais contém a presença de geração distribuida proveniente de fontes renováveis de energia. Para tanto, o problema do fluxo ótimo de potência é solucionado com a inclusão da potência injetada ou absorvida pelas baterias como variável de otimização no modelo proposto. O objetivo é que a inserção de baterias impacte de forma a reduzir os custos de energia e os custos de confiabilidade da rede, e, consequentemente provocando a diminuição dos custos totais de operação do SDE em um horizonte de planejamento de longo prazo. A utilização da meta-heurística denominada SIA se deve a sua aplicabilidade em sistemas de grande porte, visto que, nestes casos, a busca exaustiva pela melhor solução torna-se inviável. Análises utilizando cinco tipos de baterias e sua inserção em quatro sistemas de distribuição conhecidos da literatura são realizados para a validação da metodologia proposta. Resultados apresentados demonstram a aplicabilidade da metodologia proposta, assim como a viabilidade de utilização de bancos de baterias em redes de distribuição de energia. / This work presents an application for the operation planning of battery storage systems in electricity distribution networks with penetration of distributed generation from renewable sources of energy. For this, the an optimal power flow algorithm is applied with the inclusion of the power supplied or absorbed by battery banks as an optimization variable in the developed model. The objective is that the battery banks insertion impacts on the reduction of energy and reliability costs of the network, and, as a consequence, to lead in the reduction of the total costs of the distribution network in a long term operation period. The choice for a meta-heuristic called SIA is due their ability to deal with large scale problems, in which an exhaustive search would not be feasible. Analysis using five battery types applied to four well known systems in literature are performed to validate the proposed methodology. Results presented demonstrate the applicability of the proposed methodology, as well as the feasibility of using battery banks in energy distribution networks.
136

Análise técnico-econômica do impacto da penetração da geração distribuída em redes de distribuição

Machado, Ivan de Souza 03 July 2017 (has links)
Submitted by Patrícia Cerveira (pcerveira1@gmail.com) on 2017-06-07T20:58:56Z No. of bitstreams: 1 IVAN MACHADO_Dissertação.pdf: 4344558 bytes, checksum: 054d635d2c21036a970f1a9ead057382 (MD5) / Approved for entry into archive by Biblioteca da Escola de Engenharia (bee@ndc.uff.br) on 2017-07-03T13:10:58Z (GMT) No. of bitstreams: 1 IVAN MACHADO_Dissertação.pdf: 4344558 bytes, checksum: 054d635d2c21036a970f1a9ead057382 (MD5) / Made available in DSpace on 2017-07-03T13:10:58Z (GMT). No. of bitstreams: 1 IVAN MACHADO_Dissertação.pdf: 4344558 bytes, checksum: 054d635d2c21036a970f1a9ead057382 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Atualmente diversos países tem posto em prática políticas para promover a Geração Distribuída (GD). No Brasil, a Agência Nacional de Energia Elétrica (ANEEL) publicou a Resolução 482/2012 a fim de estabelecer as condições gerais de acesso da geração distribuída à rede e o mecanismo de compensação para a energia gerada pelo consumidor. Entre as tecnologias de GD, a solar fotovoltaica desempenha um papel importante devido aos seus avanços, em conjunto com a redução dos custos de capital e subsídios. A incerteza da inserção de unidades de GD renováveis pode causar impactos no sistema de distribuição de energia e vários estudos têm sido realizados para analisar os problemas relacionados a penetração da GD fotovoltaica. No entanto, em geral, esses estudos consideram cenários de penetração gerados aleatoriamente ou com base em aspectos técnicos, independentemente das características econômicas dos clientes. Portanto, esse trabalho propõe uma metodologia para avaliar o impacto da GD no sistema de distribuição considerando cenários de adoção com base nos clientes. O estudo de um alimentador de distribuição real foi desenvolvido a partir de dados do Projeto “Cidade Inteligente Búzios”. A análise e a simulação desse sistema de distribuição foram realizadas através do software Open Distribution System Simulator (OpenDSS). / Nowadays, several countries are applying energy policies to promote Distributed Generation (DG). In Brazil, the National Electric Energy Agency (ANEEL) published the Normative Resolution 482/2012 in order to establish the general conditions for access of distributed generation for the grid and compensation mechanisms for the energy generated by the consumer. Among DG technologies, solar photovoltaic plays a major role due to advances in photovoltaic technology, combined with decreasing capital costs and subsidies. The uncertainty renewable DG integration may cause impact on distribution power system and several studies have been carried out to analyze grid integration issues associated with photovoltaic DG penetration. However, in general, these studies consider penetration scenarios randomly generated or based on technical aspects, regardless economic characteristics of customers. Therefore, this paper proposes a methodology to assess the impact of DG on distribution system considering customer adoption scenarios. The study of a real distribution feeder was developed from “Smart City Búzios” project database. The analysis and the distribution system simulation were performed with the Open Distribution System Simulator Software (OpenDSS).
137

Modelo multicritério para seleção de alimentadores no processo de corte manual de cargas

MOURA, Leonardo Ferreira de 31 August 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-04-15T17:14:47Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE Leonardo Ferreira de Moura.pdf: 4686822 bytes, checksum: 4736c3ce868bd1d0d70bfb18170cebe7 (MD5) / Made available in DSpace on 2016-04-15T17:14:47Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE Leonardo Ferreira de Moura.pdf: 4686822 bytes, checksum: 4736c3ce868bd1d0d70bfb18170cebe7 (MD5) Previous issue date: 2015-08-31 / O restabelecimento do fornecimento de energia elétrica em situações de contingencia, em sistemas de distribuição de energia, envolve diversas necessidades que o tornam um problema de otimização multiobjectivo com múltiplas restrições. Dentre essas necessidades destaca-se a priorização de fornecimento aos consumidores especiais, quantidade de clientes interrompidos, número de dispositivos a serem manobrados, limite térmico dos condutores, nível de tensão, existência de paralelismo elétrico, opções de transferência disponíveis, localização das equipes e etc. Assim, técnicas para lidar com esse problema devem considerar estes aspectos de forma simultânea nos sistemas de distribuição. Face ao exposto, propõe-se nesse trabalho o estudo e aplicação de uma modelagem matemática para estabelecimento da priorização destas variáveis facilitando o processo de tomada de decisão por parte do operador do sistema elétrico. O método multicritério escolhido para a realização deste trabalho foi o da escola americana denominado de SMARTER (Simple Multi-attribute Rate Technique Exploiting Ranks). / The reestablishment of electricity supply in situations of contingency in power distribution systems, involves a number of requirements that make it a multi-objective optimization problem with multiple constraints. Among these needs stands prioritizing supply to consumers special amount of customers interrupted, number of devices to be handled, thermal limit of the conductors, voltage level, the existence of parallelism electric, transfer options available, location of teams, etc. So, techniques for dealing with this problem should consider these aspects simultaneously in distribution systems. Given the above, this work proposes study and application of a mathematical modeling to establish the prioritization of these variables facilitating the process of decision making by the Electricity System Operator. The multicriteria method chosen for this work was the American School called SMARTER (Simple Multi -attribute Rate Technique Exploiting Ranks).
138

Análise de modelos e aplicação do UPFC em sistema de 138 kV. / Models analysis and application of UPFC in 138 kV system.

Tokuno, Stanley Eidi 29 July 2016 (has links)
Este trabalho trata do UPFC (Unified Power Flow Controller), que corresponde a um dos mais promissores dispositivos FACTS de última geração, pois apresenta a capacidade de controle independente de todos os parâmetros básicos do sistema elétrico de potência (tensão, impedância e ângulo de fase). Com base nos modelos já propostos para representação deste equipamento em regime permanente, é realizada análise e proposta de um modelo que permite uma abordagem prática, para simulação do UPFC em softwares de fluxo de potência comerciais que não possuem modelos dedicados para este dispositivo. São revisitados os conceitos associados ao UPFC, com apresentação dos modelos analisados e seus respectivos parâmetros, assim como os equipamentos instalados e estimativa de custos para implantação. Através de simulações utilizando o modelo de transformador ideal associado à impedância do transformador série e compensador estático, são obtidos os parâmetros para o modelo de injeção de potências e realizadas simulações que demonstram a equivalência entre estes modelos. Finalmente, é realizada a análise de aplicação do UPFC em um sistema de distribuição de alta tensão, onde há forte presença de geração distribuída com sua sazonalidade característica e linhas que realizam a interligação entre diferentes fontes do sistema, havendo a necessidade de controle do fluxo de potência e melhoria dos níveis de tensão em função dos critérios técnicos e aspectos regulatórios. / This work is about UPFC which corresponds to one of the most promising last generation FACTS device, for it presents independent control in all basic parameters of the electrical power system (voltage, impedance and phase angle). Based on models that have already been proposed to represent this equipment in steady state, an analysis has been made and a model that permits practical approach is proposed to simulate the UPFC in commercial power flow softwares that do not yet support this device. The associated UPFC concepts are revisited with the presentation of analyzed models and their respective parameters as well as the installed equipments and cost estimate for implementation. Through simulations using ideal transformer associated to the series transformer impedance and static Var compensator model, parameters are obtained for the power injection model and simulations were run that showed a similarity between these models. Finally, a UPFC application analysis was done for a region of high voltage distribution system, where there is a strong presence of distributed generation typically seasonal and lines which connect different sources of the system, having the necessity of controlling the power flow and improvement of the voltage levels due to the technical criteria and regulatory aspects.
139

Análise de modelos e aplicação do UPFC em sistema de 138 kV. / Models analysis and application of UPFC in 138 kV system.

Stanley Eidi Tokuno 29 July 2016 (has links)
Este trabalho trata do UPFC (Unified Power Flow Controller), que corresponde a um dos mais promissores dispositivos FACTS de última geração, pois apresenta a capacidade de controle independente de todos os parâmetros básicos do sistema elétrico de potência (tensão, impedância e ângulo de fase). Com base nos modelos já propostos para representação deste equipamento em regime permanente, é realizada análise e proposta de um modelo que permite uma abordagem prática, para simulação do UPFC em softwares de fluxo de potência comerciais que não possuem modelos dedicados para este dispositivo. São revisitados os conceitos associados ao UPFC, com apresentação dos modelos analisados e seus respectivos parâmetros, assim como os equipamentos instalados e estimativa de custos para implantação. Através de simulações utilizando o modelo de transformador ideal associado à impedância do transformador série e compensador estático, são obtidos os parâmetros para o modelo de injeção de potências e realizadas simulações que demonstram a equivalência entre estes modelos. Finalmente, é realizada a análise de aplicação do UPFC em um sistema de distribuição de alta tensão, onde há forte presença de geração distribuída com sua sazonalidade característica e linhas que realizam a interligação entre diferentes fontes do sistema, havendo a necessidade de controle do fluxo de potência e melhoria dos níveis de tensão em função dos critérios técnicos e aspectos regulatórios. / This work is about UPFC which corresponds to one of the most promising last generation FACTS device, for it presents independent control in all basic parameters of the electrical power system (voltage, impedance and phase angle). Based on models that have already been proposed to represent this equipment in steady state, an analysis has been made and a model that permits practical approach is proposed to simulate the UPFC in commercial power flow softwares that do not yet support this device. The associated UPFC concepts are revisited with the presentation of analyzed models and their respective parameters as well as the installed equipments and cost estimate for implementation. Through simulations using ideal transformer associated to the series transformer impedance and static Var compensator model, parameters are obtained for the power injection model and simulations were run that showed a similarity between these models. Finally, a UPFC application analysis was done for a region of high voltage distribution system, where there is a strong presence of distributed generation typically seasonal and lines which connect different sources of the system, having the necessity of controlling the power flow and improvement of the voltage levels due to the technical criteria and regulatory aspects.
140

Localização de faltas em redes de distribuição no contexto de redes elétricas inteligentes utilizando algoritmos evolutivos. / Fault location in distribution networks in the context of smart grids utilizing evolutionary algorithms.

Pereira, Danilo de Souza 13 June 2019 (has links)
Este trabalho trata do desenvolvimento de uma metodologia e de uma ferramenta computacional de localização de faltas em sistemas elétricos de distribuição. Para tanto, considera-se o ambiente de Redes Elétricas Inteligentes, onde está à disposição uma grande diversidade de informações, como oscilografias de relés, dados de sensores, dados históricos, alarmes de medidores inteligentes, dentre outras. Convencionalmente, as metodologias de localização de defeitos em redes de distribuição se baseiam em conjuntos particulares de dados, que geralmente são medições apenas na saída do alimentador, e funcionam como uma ferramenta isolada no centro de operações. Este trabalho contribui para esse tema ao propor a Localização de Faltas como uma ferramenta de Automação Avançada, instalada em um Sistema de Gerenciamento da Distribuição. Ele deve estar integrado aos demais sistemas corporativos, dos quais obtém dados de medição, alarmes de atuação e indicação de eventos na rede, em tempo real. Um barramento de interoperabilidade permite a troca de informações entre os sistemas. O algoritmo de localização de faltas proposto considera os alarmes de atuação de chaves monitoradas, indicação de sensores, alarmes de ausência de tensão, dentre outras informações, para restringir ao máximo a área de busca do defeito. Por fim, uma implementação de Algoritmo Evolutivo permite estimar o local e a resistência de falta, a partir de testes de defeitos na área de busca. Nesse processo, os valores calculados são comparados com as medições obtidas dos respectivos pontos. Na etapa de aplicação da metodologia, foram consideradas algumas condições de monitoramento da rede elétrica: da condição de menor monitoramento ao cenário de maior monitoramento. Foi possível verificar como o aumento da quantidade de informações do sistema traz benefícios para a localização dos defeitos. / This work provides the development of a methodology and a computational tool for Fault Location (FL) in power distribution systems. The Smart Grid environment is considered, which provides a huge variety of information, such as relays waveforms, fault current sensors and historical data, smart meters alarms, among others. Conventionally, FL methodologies in power distribution systems are based on particular data sources, usually measurements at the beginning of the power feeder, which are not integrated with other corporate systems. This work contributes to the subject by proposing the FL as an Advanced Distribution Automation tool, to be installed in a Distribution Management System. As a part of the electric utility corporate systems, it obtains metering data, equipment alarms and events notifications, i.e. real time information. An Interoperability Bus (IB) allows the information exchange among the systems. The proposed FL algorithm considers monitored switches tripping alarms, current current sensors notifications, outage alarms, among other data, in order to narrow the search area as much as possible. Ultimately, an Evolutionary Algorithm (EA) implementation estimates the fault point and the fault resistance, through short-circuit tests an the search area. During that process, the computed electric quantities are compared with the measured ones at each monitored point. When applying the methodology for the case studies, some power grid monitoring conditions were considered: from the least monitored condition to the most monitored scenario. This made it possible to verify how the increase of power grid information benefits the FL algorithms.

Page generated in 0.104 seconds