• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 518
  • 95
  • 33
  • 10
  • 9
  • 9
  • 9
  • 9
  • 7
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 757
  • 507
  • 203
  • 200
  • 167
  • 103
  • 90
  • 78
  • 75
  • 75
  • 70
  • 67
  • 63
  • 60
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da resistência à fratura torcional de diferentes instrumentos rotatórios de níquel-titânio

Estrela, Cristiane Bonanato [UNESP] 16 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-16Bitstream added on 2014-06-13T20:31:51Z : No. of bitstreams: 1 estrela_cb_me_arafo.pdf: 632594 bytes, checksum: e7982adee01fe5ebe42d21b28ee2bc23 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a resistência à fratura de instrumentos rotatórios de níquel-titânio por meio de ensaio de torção. Foram avaliados os sistemas Profile 0,04/0,06 (Dentsply/Maillefer) e K3 (Kerr), perfazendo um total de 300 limas, as quais foram divididas em 5 grupos: Grupo A (Profile 0,04), Grupo B (Profile 0,06), Grupo C (K3 0,04), Grupo D (K3 0,06), Grupo E (Protaper). Os instrumentos foram submetidos a ensaio de torção por meio de um dispositivo acoplado à uma máquina de ensaios mecânicos MTS (Material Test System). Esta máquina era conectada à um microcomputador onde foram registrados os valores de carga máxima aplicada a cada lima. Tais valores foram, posteriormente aos testes, convertidos em torque (em N.cm), seguindo a fórmula: torque = carga máxima x raio. Os valores de torque máximo para fratura foram analisados estatisticamente pelo teste t de Student. Os resultados mostraram que instrumentos de maiores conicidades (Grupo B e D) são mais resistentes à fratura do que os de conicidades menores (Grupo A e C). Os instrumentos K3 0,06 necessitam de maiores valores de torque máximo para fratura em relação aos Protaper. Observamos ainda que os instrumentos do sistema K3 foram significativamente mais resistentes à fratura torcional do que os instrumentos do sistema Profile. Porém, os resultados mostraram não haver diferenças significativas na resistência à fratura entre os sistemas Profile 0,04, Profile 0,06 e K3 0,04 quando comparados ao sistema Protaper, da mesma forma que quando comparamos os sitemas Profile 0,04 com o K3 0,04. Porém, quando a comparação foi feita entre instrumentos Profile 0,06 e K3 0,06, os últimos mostraram-se mais resistentes à fratura que os primeiros. / The aim of this study was to evaluate the resistance of different nickel-titanium rotary instruments to the fracture by means of torsion test. Profile 0,04/0,06 (Dentsply/Maillefer), Protaper (Dentsply/Maillefer) and K3 ENDO (Kerr) systems were evaluated, resulting in 300 files which were divided in 5 groups: Group A (Profile 0,04), Group B(Profile 0,06), Group C (K3 0,04), Group D (K3 0,06), Group E (Protaper). The instruments were subjected to torsion test by means of an appliance coupled to a mechanical test machine MTS (Material Test System). This machine was connected to a microcomputer in which was registered the values of maximum load applied to each file. Such values were, after the tests, converted to torque (in N.cm), following the formula: torque=maximum load x radius. Maximum torque values for fracture were analyzed statistically by the Student's t. The results showed that more taper instruments (Groups B and D) are more resistant to fracture than the less taper ones (Groups A and C). The K3 0,06 instruments need higher values of maximum torque to fracture with relation to Protaper's ones. We also noticed that the instruments from K3 system were significantly more resistant to the torsion fracture than the Profile system instruments. However, the results showed that there are not significant differences in the resistance to the fracture among the systems Profile 0,04, Profile 0,06 and K3 0,04 when they were compared to Protaper system, as the same way when we compare Profile 0,04 systems to K3 0,04.
52

Terapia fotodinâmica em dentes contaminados com Enterococcus faecalis utilizando a curcumina como fotossensibilizador

Frota, Matheus Franco da [UNESP] 01 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-01Bitstream added on 2014-06-13T20:12:43Z : No. of bitstreams: 1 frota_mf_me_arafo.pdf: 715570 bytes, checksum: 00d99e88a103b81985ddb8a15deccf49 (MD5) / O estudo avaliou a eficácia antibacteriana da terapia fotodinâmica (TFD) em canais radiculares contaminados com Enterococcus faecalis, utilizando o LED como fonte de luz e a curcumina como agente fotossensibilizador (FS) em diferentes tempos de irradiação. Oitenta raízes de dentes humanos unirradiculados foram fixados em placas de 24 poços. Todos os espécimes foram submetidos ao preparo biomecânico utilizando o sistema Protaper Universal® (Dentsply-Maillefer, Ballaigues, Suíça) na sequência técnica preconizada pelo fabricante até o instrumento F4, sendo, a seguir, esterilizados e distribuídos aleatoriamente nos seguintes grupos e sub-grupos (n=10): GIa: TFD (curcumina com 5 minutos de pré-irradiação + 5 minutos de irradiação); GIb: TFD (Curcumina com 5 minutos de pré-irradiação + 10 minutos de irradiação); GIIa: Curcumina com 5 minutos de pré-irradiação + 5 minutos sem irradiação; GIIb: Curcumina 5 minutos + 10 minutos sem irradiação; GIIIa: Soro fisiológico + Luz por 5 minutos; GIIIb: Soro fisiológico + luz 10 minutos; Grupos controle positivo e negativo. As coletas deram-se aos 21 dias da contaminação, pós- tratamento e 7 dias pós-tratamento. Os dados obtidos (UFC/mL) foram submetidos aos testes de ANOVA e Tukey com nível de significância de 5%. Os resultados mostraram redução bacteriana nos grupos GIa e GIb de forma significante em relação aos demais grupos no pós tratamento e, aos 7dias, somente em relação ao GIIIa (P<0,05). A TFD não foi eficaz na eliminação de E. faecalis dos canais radiculares. O tempo de irradiação de 10 minutos foi irrelevante em relação ao efeito da TFD / The study evaluated the antibacterial efficacy of photodynamic therapy (PDT) in root canals contaminated with Enterococcus faecalis, using LED as light source and curcumin as photosensitizer agent (FS) at different irradiation times. Eighty single-rooted and single-canalled human extracted teeth were selected for this study that were fixed in 24 well plates and contaminated by suspensions of E. faecalis for 21 days. All specimens were subjected to biomechanical preparation using Protaper Universal® (Dentsply-Maillefer, Ballaigues, Switzerland) system following the technique recommended by the manufacturer to the F4 instrument, and, then, sterilized and randomly divided into the following groups and sub-groups (n = 10): GIa: PDT (curcumin with 5 minutes of pre-irradiation time + 5 min of irradiation); GIb: PDT (curcumin with 5 minutes of pre-irradiation + 10 min irradiation); GIIA: 5 minutes with curcumin pre-irradiation + 5 minutes without irradiation; GIIB: Curcumin 5 minutes + 10 minutes without irradiation; GIIIa: saline + light for 5 minutes; GIIIb: saline + light 10 minutes; positive and negative control groups. The collected times of samples were after 21 days of infection, post-treatment and 7 days after treatment. The data (CFU mL-1) were submitted to ANOVA and Tukey test. Results showed bacterial reduction only in the group GIa and GIb significantly in relation to other groups in post-treatment (P <0.05). PDT was not effective in eliminating E. faecalis from root canals. The irradiation time of 10 minutes did not improve the effect of PDT
53

Impacto da incorporação de substâncias químicas nas propriedades físico-químicas dos cimentos endodônticos /

Keine, Katia Cristina. January 2014 (has links)
Orientador: Gisele Faria / Banca: Marco Antonio Hungaro Duarte / Banca: Idomeo Bonetti Filho / Resumo: Avaliar os efeitos da incorporação do iodofórmio ou do hidróxido de cál-cio (HC) respectivamente no cimento Sealer 26 ou MTA Fillapex (MF). Na ava-liação com o Sealer 26, as proporções de 1.1g, 0,55g or 0.275g foram incorpo-radas ao cimento e o de tempo de presa, escoamento, solubilidade, pH e libe-ração de cálcio foram avaliados. Na análise do MF puro, acrescido de 5% (MF5) ou 10%(MF10) em massa de HC, o escoamento, pH e liberação de cál-cio foram comparados com AH Plus. A adição do iodofórmio ao Sealer26 au-mentou o tempo de presa do cimento (p<0,05), mas os demais resultados fo-ram similares (p>0,05). Em 24hs, a mistura com 1.1g: 0.55g de iodofórmio de-monstrou menor pH que o cimento puro (p<0,05). O MF teve maior escoamento que os demais cimentos (p<0,05). O MF10 apresentou menor escoamento que MF (P<0,05). O MF10 apresentou maior pH que o AH Plus (p<0,05).A liberação de cálcio foi similar ao MF e o MF10 (p>0,05). O MF5 demonstrou menor esco-amento que o MF e maior que MF10 (p<0,05), tendo maior valor de pH que o MF (p<0,05) e similar liberação de cácio ao MF10. A adição do iodofórmio inter-fere no tempo de presa e solubilidade do Sealer 26 e a adição de 5%HC no MF apresentou-se como alternativa para reduzir o escoamento, sem interferir no potencial de alcalinização do MF. / Abstract: To evaluate the effects of incorporation of iodoform or calcium hydroxide (CH) respectively in cement Sealer 26 or MTA Fillapex (MF) . In review with the Sealer26, the proportions of 1.1g, 0.55g or 0.275g were incorporated into the cement and the setting time, flow, solubility, pH and calcium release were evaluated. The analysis of pure MTA Fillapex (MF) or containing 5% (MF5) or 10% (MF 10) calcium hydroxide (CH), in weight, in comparison with AH Plus sealer .The addition of iodoform to Sealer26 cement increased setting time(p < 0.05), but the other results were similar (p> 0.05). In 24 hours, the mixture with 1.1g : 0.55g iodoform showed lower pH than the pure cement ( p < 0.05 ) . The MF had greater flow than the other cements ( p < 0.05 ) . The MF10 showed lower flow that MF ( P < 0.05 ) . The MF10 showed pH greater than AH Plus (p < 0.05). Calcium realise was similar to MF and MF10 (p> 0.05). The MF5 showed less than the flow MF , and greater than MF10 (p <0.05 ), and higher pH value than the MF (p <0.05) and calcium release similar to MF10 . The addi-tion of iodoform interferes with the setting time and solubility of Sealer 26 and the addition of 5% CH in the MF presented as an alternative to reduce the flow without interfering with potential alkalization. / Mestre
54

Terapia fotodinâmica em dentes contaminados com Enterococcus faecalis utilizando a curcumina como fotossensibilizador /

Frota, Matheus Franco da. January 2013 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Co-orientador: Juliane Maria Guerreiro Tanomaru / Banca: Antônio Miranda da Cruz Filho / Banca: Idomeo Bonetti Filho / Resumo: O estudo avaliou a eficácia antibacteriana da terapia fotodinâmica (TFD) em canais radiculares contaminados com Enterococcus faecalis, utilizando o LED como fonte de luz e a curcumina como agente fotossensibilizador (FS) em diferentes tempos de irradiação. Oitenta raízes de dentes humanos unirradiculados foram fixados em placas de 24 poços. Todos os espécimes foram submetidos ao preparo biomecânico utilizando o sistema Protaper Universal® (Dentsply-Maillefer, Ballaigues, Suíça) na sequência técnica preconizada pelo fabricante até o instrumento F4, sendo, a seguir, esterilizados e distribuídos aleatoriamente nos seguintes grupos e sub-grupos (n=10): GIa: TFD (curcumina com 5 minutos de pré-irradiação + 5 minutos de irradiação); GIb: TFD (Curcumina com 5 minutos de pré-irradiação + 10 minutos de irradiação); GIIa: Curcumina com 5 minutos de pré-irradiação + 5 minutos sem irradiação; GIIb: Curcumina 5 minutos + 10 minutos sem irradiação; GIIIa: Soro fisiológico + Luz por 5 minutos; GIIIb: Soro fisiológico + luz 10 minutos; Grupos controle positivo e negativo. As coletas deram-se aos 21 dias da contaminação, pós- tratamento e 7 dias pós-tratamento. Os dados obtidos (UFC/mL) foram submetidos aos testes de ANOVA e Tukey com nível de significância de 5%. Os resultados mostraram redução bacteriana nos grupos GIa e GIb de forma significante em relação aos demais grupos no pós tratamento e, aos 7dias, somente em relação ao GIIIa (P<0,05). A TFD não foi eficaz na eliminação de E. faecalis dos canais radiculares. O tempo de irradiação de 10 minutos foi irrelevante em relação ao efeito da TFD / Abstract: The study evaluated the antibacterial efficacy of photodynamic therapy (PDT) in root canals contaminated with Enterococcus faecalis, using LED as light source and curcumin as photosensitizer agent (FS) at different irradiation times. Eighty single-rooted and single-canalled human extracted teeth were selected for this study that were fixed in 24 well plates and contaminated by suspensions of E. faecalis for 21 days. All specimens were subjected to biomechanical preparation using Protaper Universal® (Dentsply-Maillefer, Ballaigues, Switzerland) system following the technique recommended by the manufacturer to the F4 instrument, and, then, sterilized and randomly divided into the following groups and sub-groups (n = 10): GIa: PDT (curcumin with 5 minutes of pre-irradiation time + 5 min of irradiation); GIb: PDT (curcumin with 5 minutes of pre-irradiation + 10 min irradiation); GIIA: 5 minutes with curcumin pre-irradiation + 5 minutes without irradiation; GIIB: Curcumin 5 minutes + 10 minutes without irradiation; GIIIa: saline + light for 5 minutes; GIIIb: saline + light 10 minutes; positive and negative control groups. The collected times of samples were after 21 days of infection, post-treatment and 7 days after treatment. The data (CFU mL-1) were submitted to ANOVA and Tukey test. Results showed bacterial reduction only in the group GIa and GIb significantly in relation to other groups in post-treatment (P <0.05). PDT was not effective in eliminating E. faecalis from root canals. The irradiation time of 10 minutes did not improve the effect of PDT / Mestre
55

Análise radiográfica, tomográfica e microscópica do desenvolvimento da lesão periapical em dentes de cães /

Jorge, Érica Gouveia. January 2008 (has links)
Orientador: Mário Tanomaru Filho / Banca: Clóvis Monteiro Bramante / Banca: Marcelo Gonçalves / Resumo: O objetivo deste estudo foi a avaliação radiográfica, tomográfica e microscópica do desenvolvimento da lesão periapical induzida em dentes de cães. Foram utilizados pré-molares de 4 cães, os quais tiveram seus canais radiculares expostos ao meio bucal por 7 dias para contaminação e posteriormente selados por: GI- 7 dias, GII- 15 dias, GIII- 30 dias e GIV- 60 dias. No período inicial e nos períodos experimentais foram realizadas radiografias padronizadas e ao final dos períodos tomografias para avaliação da região periapical. Após a morte dos animais foi efetuada o processamento histopatológico dos tecidos periapicais. As radiografias periapicais foram digitalizadas e a área de reabsorção óssea mensurada. As tomografias foram avaliadas por meio de escores baseados na evolução da reabsorção óssea periapical. A avaliação histopatológica foi realizada de acordo com os seguintes parâmetros: reabsorção cementária apical e óssea periapical, intensidade e extensão do infiltrado inflamatório. Os resultados radiográficos foram submetidos à ANOVA e ao teste de Tukey (α=0,05) e os tomográficos e histológicos ao teste de Kruskal-Wallis e Dunn (α=0,05). A avaliação radiográfica não demonstrou lesões radiográficas no período de 7 dias. Lesões periapicais radiográficas foram observadas nos períodos de 15 e 30 dias (47,4% e 77,8% dos casos respectivamente), com dimensões semelhantes (p>0,05). As lesões foram detectadas em todos os casos aos 60 dias, sendo maior que nos demais grupos (p<0,05). A avaliação tomográfica possibilitou a detecção das lesões periapicais nos períodos de 7 dias e 15 dias (32,5% e 83,3% dos casos respectivamente). Todos os casos apresentavam lesões nos períodos de 30 e 60 dias, quando foram observados os maiores valores de reabsorção óssea (p<0,05). A avaliação histológica mostrou áreas de reabsorção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was the radiographic, tomographic and microscopic evaluation of the development of the induced chronic periapical periodontitis in dog's teeth. The root canals of premolars from four dogs were exposed to the oral environment for seven days for contamination, and then sealed for: GI- 7 days, GII- 15 days, GIII- 30 days, and GIV- 60 days. Immediately after each experimental period, radiographs and tomograms were performed in order to detect periapical bone resorption. The groups was done in the same animal. After the death of the animals, the histopathological evaluation of the apical and periapical tissues was realized. The periapical radiographs were digitized and bone resorption areas were measured. The tomograms were assigned scores based on the evolution of periapical bone resorption. Histopathogical analysis was performed according to the following parameters: apical cementum resorption and periapical bone resorption, intensity and extension of inflammatory infiltrate. The number of inflammatory cells and the area of histological bone resorption were measured using the Image ProPlus 6.1 software. The radiographic results were analyzed by ANOVA and Tukey tests (α=0.05) and the tomography and histological results were analyzed by the Kruskal-Wallis and Dunn tests (α=0.05). So, it was evaluated the development of the chronic periapical periodontitis with the increase of time and the correlation with the osseus resorption by using radiographs and tomograms of the periapical region. The radiographic evaluation did not reveal periapical lesions at 7 days. Lesions could be radiographically observed after 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (p>0.05). Lesions were detected in all cases at 60 days, with larger dimensions than those in the previous... (Complete abstract click electronic access below) / Mestre
56

Avaliação das alterações geométricas e dimensionais dos instrumentos de NiTi do sistema ProTaper para o sistema ProTaper universal e o efeito destas sobre a flexibilidade e a resistência torcional /

Câmara, Alexandre Sandri. January 2008 (has links)
Orientador: Renato de Toledo Leonardo / Banca: Mario Tanomaru Filho / Banca: Idomeo Bonetti Filho / Banca: Manoel Eduardo de Lima Machado / Banca: Maria Guiomar de Azevedo Bahia / Resumo: O presente trabalho se propôs a avaliar as alterações geométricas e dimensionais dos instrumentos de NiTi do sistema ProTaper Universal em relação ao sistema ProTaper, bem como o efeito destas sobre a flexibilidade e a resistência à torção dos instrumentos. Um total de 298 instrumentos foram empregados neste estudo. Inicialmente, 12 instrumentos de cada tipo dos dois sistemas foram submetidos a uma caracterização geométrica e dimensional por microscopia óptica. Foram avaliados os parâmetros ângulo, comprimento e diâmetro de ponta, comprimento de cada pitch ao longo das hastes e diâmetro do instrumento a cada milímetro da ponta. Além disso, a área da secção transversal destes instrumentos a 3mm a partir da ponta foi determinada em imagens obtidas por microscopia eletrônica de varredura, usando 01 instrumento de cada formato. Após isto, todos os instrumentos foram aleatoriamente divididos em 4 grupos distintos: Grupo 1 contendo 60 instrumentos ProTaper S1, S2, F1, F2 e F3, sendo 12 unidades de cada formato para os ensaios de torção; Grupo 2 contendo 60 instrumentos ProTaper S1, S2, F1, F2 e F3, sendo 12 unidades de cada formato para os ensaios de flexibilidade; Grupo 3 contendo 84 instrumentos ProTaper Universal S1, S2, F1, F2, F3, F4 e F5, sendo 12 unidades de cada formato para os ensaios de torção; Grupo 4 contendo 84 instrumentos ProTaper S1, S2, F1, F2, F3, F4 e F5, sendo 12 unidades de cada formato para os ensaios de flexibilidade. Tais ensaios de torção e flexibilidade foram executados de acordo com a especificação ISO 3630-1 em um dispositivo de bancada para testes utilizando um programa para aquisição e processamento dos dados especialmente desenvolvido para este fim. Os valores para torque máximo, deflexão angular até a fratura e momento de dobramento foram analisados estatisticamente pelo teste... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study has proposed to evaluate the instruments structural changes from NiTi ProTaper System to NiTi ProTaper Universal System as well this effect over torsional resistance and flexibility. It was used a total amount of 298 instruments. At the beginning, 12 instruments of each size from both systems were analyzed dimensional and geometrically by optical microscopy under parameters of angle, length and tip diameter, pitch's length along the blade and instrument's diameter from tip until the end of the active part. Besides, one sample of each size had its 3-mm from the tip's cross sectional area calculated under SEM images. After that, all the instruments were randomly divided into 4 different groups: Group 1 having 60 ProTaper instruments inside (S1, S2, F1, F2 and F3),12 samples from each size, to be submitted to torsion test; Group 2 having 60 ProTaper instruments inside (S1, S2, F1, F2 and F3),12 samples from each size, to be submitted to bending test; Group 3 having 84 ProTaper Universal instruments inside (S1, S2, F1, F2, F3, F4 and F5),12 samples from each size, to be submitted to torsion test; Group 4 having 84 ProTaper instruments inside (S1, S2, F1, F2, F3, F4 and F5),12 samples from each size, to be submitted to bending test. These torsion and bending tests were performed using a bench test device connected with a software to acquire and process data specially developed to this purpose, according to ISO 3630-1. Maximum torque, angular deflection until fracture and bending moment values were statistically analysed using Student's t test. The results have shown that ProTaper and ProTaper Universal system's instruments presented good geometric standardization and acceptable surface features, however differences were detected among the systems. The maximum torque and the bending moment at 45º. were higher for instruments... (Complete abstract click electronic access below) / Doutor
57

Influência da limpeza mecânica com e sem o uso do microscópio operatório na resistência adesiva intrarradicular / Influence of mechanical cleaning with and without the use of the operating microscope in intraradicular adhesive strength

Ferreira, Ricardo, 1965- 02 October 2012 (has links)
Orientador: Alexandre Augusto Zaia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:27:52Z (GMT). No. of bitstreams: 1 Ferreira_Ricardo_D.pdf: 7849223 bytes, checksum: c0f3fb19c86238de581b6cb87528b99f (MD5) Previous issue date: 2012 / Resumo: No tratamento endodôntico é primordial a necessidade de restaurar o elemento dental, devolvendo as suas funções, tendo em vista as possibilidades de recontaminação do sistema de canais radiculares e fraturas. Estes riscos são ainda maiores em casos de perda de estrutura dentária que necessitam de pinos intrarradiculares para reter os procedimentos restauradores. Para a restauração definitiva e imediata destes dentes, a cimentação adesiva de pinos de fibra de vidro é uma excelente opção. No entanto, a adesão à dentina radicular apresenta algumas dificuldades, em virtude de suas características morfológicas, como menor número e diâmetro de túbulos dentinários, alto fator C, distância da fonte de luz, além de resíduos de substâncias e materiais obturadores utilizados durante o tratamento endodôntico. Desta forma o objetivo deste trabalho foi avaliar a influência da limpeza mecânica das paredes dentinárias do espaço para pino, sob a visão ou não de um microscópio operatório, na resistência de união do pino de fibra à dentina radicular. Quarenta e cinco raízes de incisivos bovinos foram tratadas endodonticamente, irrigadas com hipoclorito de sódio a 5,25% e obturadas com cimento à base de eugenol Pulp Canal Sealer¿. Para o grupo 1 (G1) controle, o preparo para pino foi realizado em 10 milímetros (mm) com instrumento aquecido, brocas de Gates Glidden número (#) 5 e do sistema White Post DC© # 2, limpeza com microaplicador e álcool 70% e copiosa irrigação com solução fisiológica (NaCl). O grupo 2 (G2) após preparo idêntico, foi realizado uma limpeza superficial e delicada com uma sequência de brocas esféricas longas (HL) # 4, 2 e 1 com velocidade controlada de 500 rotações por minutos (rpm) e torque de 0,8 Newton (N), limpeza com microaplicador e álcool 70%, seguida de irrigação com NaCl. O grupo 3 (G3) teve preparo idêntico ao G2, porém esta limpeza com brocas esféricas foi realizada sob visão de um microscópio operatório com magnificação de oito vezes. Após cimentação adesiva dos pinos de fibra de vidro White Post DC© # 2 com o adesivo autocondicionante Clearfil¿ SE Bond e cimento resinoso dual RelyX¿ ARC, foram obtidos dois cortes de 1 mm de espessura de cada terço (cervical, médio e apical) e submetidos ao ensaio mecânico de cisalhamento por extrusão. Os resultados em megapascal foram analisados através do teste não paramétrico de Kruskal-Wallis (p<0,05) e teste Student-Newman-Keuls (p<0,05). O G3 apresentou maior resistência de união (2,37MPa) que o G1 (0,95MPa) e G2 (1,04MPa) que por sua vez, não diferiram entre si. Conclui-se que a limpeza mecânica das paredes dentinárias do espaço para pino com o uso superficial e delicado de brocas esféricas HL, em 500 rpm, sob magnificação de oito vezes de um microscópio operatório (G3) foi mais eficiente que os demais grupos, proporcionando maior resistência de união entre o pino de fibra e a dentina radicular / Abstract: In endodontic treatment, there is an imperative need to restore the tooth, reestablishing its functions, since there is always a risk of recontamination of the root canal system and fractures. These risks are higher when there is loss of dental structure, requiring intraradicular posts to hold the restoration procedures in place. For the definitive and immediate restoration of these teeth, adhesive bonding of fiberglass posts is a good option. However, adhesion to the root dentin presents some difficulties due to its morphological characteristics, such as reduced number of dentinal tubules, lower diameter of dentinal tubules, high C factor, distance from light source, and residues from restoring substances and materials used during the endodontic treatment. The objective of this study is, therefore, to evaluate whether mechanical cleaning of dentinal walls of the post space, whether under microscopy or not, is able to improve bond strength between the fiber post and the root dentin. The roots of 45 bovine incisive teeth were endodontically treated, irrigated with 5.25% sodium hypochlorite and restored with Pulp Canal Sealer¿. For Group 1 (G1), the control group, the post space was prepared in 10mm, with heated instrument, and cleaning was carried out using microapplicator and 70% alcohol, Gates Glidden #5 and White Post DC2© burs, with abundant irrigation with physiological saline solution (NaCl). After identical preparation for Group 2 (G2), gentle superficial cleaning was carried out using a sequence of long round # 4, 2 and 1 burs (HL), controlled speed of 500 rotations per minute (rpm) and torque of 0.8 Newton (N), cleaning using microapplicator and 70% alcohol, followed by irrigation with NaCl. Group 3 (G3) was prepared in the same way as G2, with the exception that the superficial cleaning with round burs was carried out under microscope, with a magnification of eight times. After adhesive bonding of White Post DC2© fiberglass posts using self-etching adhesive Clearfil¿ SE Bond and dual RelyX¿ ARC dual core resin cement, two 1mm thick sections were obtained from each third (cervical, middle, apical) and then submitted to the push-out test. The results in megapascal were analyzed through the Kruskal-Wallis nonparametric tests (p<0.05) and the Student-Newman-Keuls test (p<0.05). G3 presented the highest bond strength (2,37MPa) compared to G1 (0,95MPa) and G2 (1,04MPa), which, in turn, presented similar results. It is concluded that mechanical cleaning the dentinal walls of the post space with the superficial and gentle use round burs (HL) at 500 rpm, under surgical microscope with magnification of eight times (G3), showed the highest bond strength between the fiberglass post and the root dentin / Doutorado / Endodontia / Doutor em Clínica Odontológica
58

Root and canal configurations of mandibular molars using CBCT, with an emphasis on middle mesial canals

Tredoux, Sheree January 2020 (has links)
Introduction: An extensive knowledge of dental root and canal anatomy is essential to clinicians performing endodontic treatment. It is well-known that dental anatomy may be complex and display significant variation. Aim: The aim of the present study was to classify the root number and the root canal configurations of human mandibular first and second molars in a South African sub-population using CBCT. Materials and methods: The study design was a retrospective cross-sectional descriptive study. The sample size included 753 molars. The CBCT images of each individual mandibular first and second molar were evaluated in coronal, sagittal and axial views. Classification of the canal configurations of each root was made using the Vertucci classification system, including the additions proposed by Sert and Bayirli. Classification of root number was described as one, two, three, or four-roots. Results: Root anatomy: Two-rooted configurations were demonstrated in the majority of first and second molars (98.7% and 94%). One- and three-rooted molars were rare with a prevalence ranging from 0.3% to 2.9%. Half of all three-rooted molars presented with two distinct mesial roots. Four-rooted molars were found in second molars only (0.5%). Canal anatomy: The most common canal type in the mesial roots of mandibular first and second molars was Type IV (50% and 38%) followed by Type II (21% and 24%). The most common canal configuration in the distal roots of the first and second molars was Type I (50% and 81%) followed by Type V (20% and 10%). More than two mesial canals in mandibular first and second molars were present in 21% and 17% of the sample. More than two distal canals were demonstrated in first and second molars in 7% and 2% of the sample. C-shaped canal systems were found in 0.5% of first molars and 7.7% of second molars. Sex and age had no correlation to root or canal configurations. Conclusion: More than two mesial canals were found in about one-fifth of the sample. It is important for clinicians to be aware that a number of mandibular molars may present with more intricate anatomy than expected during endodontic treatment and that this may affect treatment outcomes. / Dissertation (MSc (Dent))--University of Pretoria, 2020. / Odontology / MSc (Dent) / Unrestricted
59

The structural and physical properties of endodontic instruments

Germain, Lisa P. January 1981 (has links)
Black and white photographs included. / Thesis (M.Sc.D.)--Boston University, Henry M. Goldman School of Graduate Dentistry, 1981 (Endodontics) / Bibliography : leaves 293-298. / Endodontic instruments are manufactured by many companies throughout the world. Since no evidence exists in the literature concerning the variable quality of the instruments on the market, the following investigation was undertaken with the objective to compare a sample of instruments from some of the various companies. A total of 1,680 files, reamers and hedstrom files representing seven different manufacturing companies were tested. Sizes 15, 30 and 50 were selected to represent the total size range of instruments. The following physical properties were measured: 1) Torsion; 2) Angular Deflection; 3) Stiffness; 4) Dimensional Standardization; 5) Preparation for Delivery; and 6) Corrosion Resistance. The data for each company was compared with the minimum Standard set by the ANSI for the American Dental Association in Specification No. 28 for files and reamers and Specification No. 58 for headstrom files. An analysis of variance and T-tests were also performed on the data to compare and contrast the instruments between companies. The results obtained showed that there was very little uniformity of standardization between manufacturers, as well as within manufacturing companies. The quality of the initial stainless steel wire may determine the quality and strength of the final product of an endodontic instrument. It is difficult to determine whether one instrument is better than another. Each instrument has different physical properties than every other instrument.
60

Investigation of periodontal stem cell attachment to dentin and dental pulp stem cell migration

Elseed, Mohammed 01 July 2007 (has links)
July 2007 "A thesis submitted to the College of Dental Medicine of Nova Southeastern University of the degree of Master of Science [Dental Medicine]."

Page generated in 0.033 seconds