Spelling suggestions: "subject:"alectric insulator"" "subject:"delectric insulator""
1 |
Anomalous conduction as a cause of dielectric absorptionMarvin, Richard Hale, Whitehead, J. B. January 1928 (has links)
Thesis (Ph. D.)--Johns Hopkins University, 1928. / Cover title. Vita. "By J.B. Whitehead and R.H. Marvin." "Report to Engineering foundation of an experimental research conduceted in the Laboratory of electrical engineering of the Johns Hopkins university, Baltimore, MD." Bibliography: p. 15-16.
|
2 |
The influence of residual air on the life of impregnated paper insulationHamburger, Ferdinand, Whitehead, J. B. January 1900 (has links)
Thesis (Ph. D.)--John Hopkins University, 1931. / "By J.B. Whitehead and F. Hamburger, jr." Vita. "Presented at the summer convention of A.I.E.E., Asheville, N.C., June 22-26, 1931." Bibliography: p. 11.
|
3 |
A new method for impregnating oil-paper and wax-paper capacitorsWaterman, Herbert, January 1934 (has links)
Thesis (Ph. D.)--Columbia University, 1934. / Vita. Bibliography: p. 41-42.
|
4 |
High voltage, high vacuum performance of epoxy coated electrodes with thin conducting aluminum filmsWilkinson, Robert Arthur, January 1969 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1969. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
5 |
High voltage vacuum insulation with epoxy coated cathodesTowliati, Seyed Youssef, January 1968 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1968. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
6 |
Dissipation factor measurements of transformer oilSmith, Frank Edward January 1951 (has links)
The present methods of ascertaining the probable sludging of transformer oils are laborious. A simple test, comparable to that used in obtaining the dielectric strength, would be of considerable value in reducing test manpower, equipment and expense.
Present investigators measure such properties as oxygen absorption, colour change, increase in acidity, carbon dioxide evolved, water formed, the power factor, and the lnterfacial-tension value.
Numerous dielectric materials exhibit anomalous dispersions. The attendant rise in dissipation factor encountered at the points of dispersion is helpful in determining the amounts and types of polarization present. Transformer oils, although initially non-polar, are subject to oxidation. This oxidation produces materials of polar molecular structure which govern the power loss in alternating current electric fields. The problem is one of correlating such losses to the state of the oil under test.
This thesis deals with the investigations carried out on the above problem. Absorption bands for transformer oils have been found. The present work describes the presence and location of such absorption bands, and illustrates how the dipolar state of the oil affects the position of the loss peaks. / Applied Science, Faculty of / Electrical and Computer Engineering, Department of / Graduate
|
7 |
Electric field and voltage distributions along non-ceramic insulators /Que, Weiguo January 2002 (has links)
No description available.
|
8 |
PD characteristics of typical MV XLPE power cable termination defects at VLF and power frequency test voltagesFynes-Clinton, Daniel 11 October 2016 (has links)
A research report submitted to the Faculty of Engineering and the
Built Environment, University of the Witwatersrand, in ful lment
of the requirements for the degree of Master of Science in
Engineering.
June 2016 / It has been reported in literature that newly installed cable accessories can pass
typical commissioning tests and yet show signi cant PD activity leading to premature
failure in the long term. This research report details the partial discharge (PD)
characterisation of three arti cial defects in MV cable terminations, at both power
and very low frequency (VLF). The defects included a semi-conductor feather, a
tram line in the cross-linked polyethylene (XLPE) insulation and an XLPE ring
cut. The experimental methodology involved subjecting the terminations to a
standard overvoltage withstand test, after which the PD activity was monitored,
at 0.1 Hz and at 50 Hz excitation frequencies. All the defects passed the overvoltage
test, despite some showing signi cant discharges. The defects gave distinct
phase-resolved PD patterns that are e ectively invariant of excitation frequency.
The PD magnitudes at power frequency were typically bigger than at VLF, while
the PD inception voltages tended to be lower at VLF. The PD magnitudes of
the semi-conductor feather defect surface discharges were found to increase with
increasing applied voltage, while no increase was observed for the tram line and
ring cut void discharges. The results show that common installation defects in MV
cable terminations can be suitably characterised using VLF PD measurements / MT2016
|
9 |
THE ELECTRICAL PROPERTIES OF CERAMIC INSULATORS AT HIGH TEMPERATURES AND IN RADIATION FIELDSBregar, John Francis, 1923- January 1966 (has links)
No description available.
|
10 |
Radiation induced conductivity in insulatorsBohren, Craig F., 1940- January 1966 (has links)
No description available.
|