Spelling suggestions: "subject:"eletricidade."" "subject:"letricidade.""
41 |
Diretrizes da governança corporativa adotadas por uma distribuidora de energia elétrica na implementação da excelência da gestãoLima, Ana Virginia Souza de January 2014 (has links)
LIMA, Ana Virgínia Souza de. Diretrizes da governança corporativa adotadas por uma distribuidora de energia elétrica na implementação da excelência da gestão. 2014. 149 f. Dissertação (Mestrado) - Universidade Federal do Ceará, Faculdade de Economia, Administração, Atuária e Contabilidade, Programa de Pós-Graduação em Administração e Controladoria, Fortaleza-CE, 2014. / Submitted by Cleverland Santos (cleverland@ufc.br) on 2017-11-13T16:39:46Z
No. of bitstreams: 1
2014_dis_avslima.pdf: 1449349 bytes, checksum: 52431ea31b6949ac374e2e121bb1dea7 (MD5) / Approved for entry into archive by Dioneide Barros (dioneidebarros@gmail.com) on 2017-11-13T18:27:09Z (GMT) No. of bitstreams: 1
2014_dis_avslima.pdf: 1449349 bytes, checksum: 52431ea31b6949ac374e2e121bb1dea7 (MD5) / Made available in DSpace on 2017-11-13T18:27:09Z (GMT). No. of bitstreams: 1
2014_dis_avslima.pdf: 1449349 bytes, checksum: 52431ea31b6949ac374e2e121bb1dea7 (MD5)
Previous issue date: 2014 / According to the Code of Best Corporate Governance Practices of the IBGC, corporate
governance is a system in which organizations are directed, monitored and encouraged, where
good practices are translate into recommendations that align interests to preserve and enhance
the value of organizations and the relationship between stakeholders. Models of global
corporate bring features that involve from the form of funding, through the control and
management, and there is a single, universal model, but the result of cultural and institutional
diversity of nations. The FNQ®, in turn, seeks to encourage the implementation MEG®
through PNQ® that analyzes among the 23 items of eight criteria of excellence, corporate
governance, which is the first item evaluated in item management excellence of the
implementation of Leadership in management processes. In this context, this research has as
main objective to analyze the guidelines of corporate governance and how their practices,
duly assessed by PNQ® contributed in the implementation of management excellence of a
distributor of electricity. This is a descriptive study with qualitative approach, carried out by a
single case study in Coelce. To achieve the proposed objectives in the research were applied
the steps of literature, which consisted of a literature review on the topic Corporate
Governance and management excellence model; documentary research they were consulted
technical publications FNQ®, management reports and evaluation of PNQ®, information
available on the websites of the IBGC, the CVM, the FNQ ® and Coelce; and field research
in the collection procedures were interviews with the Executive Board and the application of
questionnaires to a group of company employees. The results of the comparative analysis of
the global models of governance and corporate governance model Coelce revealed that the
company showed a closer relationship with the characteristics of German and Latin American
models with adherence 50% of the 10 characteristics cataloged by Andrade and Rossetti
(2012). By means of documentary analysis of PNQ® Assessment Reports was possible to see
an increase of 40% of the total of 40 points of corporate governance item in the period 2008
to 2011. For the field research, it concluded that the implementation of management
excellence in Coelce had the guidelines of corporate governance, the support and the
materialization of actions that contributed to improvements in organizational management. / De acordo com o Código das Melhores Práticas de Governança Corporativa do IBGC, a
governança corporativa é um sistema em que as organizações são dirigidas, monitoradas e
incentivadas, em que as boas práticas são convertidas em recomendações que alinham
interesses para preservar e aperfeiçoar o valor das organizações e do relacionamento entre as
partes interessadas. Os modelos de governança corporativa mundiais trazem características
que envolvem desde a forma de financiamento, passando pelo controle e pela gestão, não
existindo um modelo único e universal, e sim resultante da diversidade cultural e institucional
das nações. A FNQ®, por sua vez, busca incentivar a implementação MEG® através do
PNQ® que analisa entre os 23 itens de oito critérios de excelência, a governança corporativa,
que é o primeiro item avaliado no item Liderança da implementação da excelência da gestão
nos processos gerenciais. Nesse contexto, a presente pesquisa tem como objetivo geral
analisar as diretrizes da governança corporativa e como suas práticas, devidamente avaliadas
pelo PNQ®, contribuíram na implementação da excelência da gestão de uma distribuidora de
energia elétrica. Trata-se de uma pesquisa descritiva, com abordagem qualitativa dos dados,
realizada por meio de estudo de caso único na empresa Coelce. Para o alcance dos objetivos
propostos na pesquisa foram aplicadas as etapas de pesquisa bibliográfica, que consistiu na
revisão de literatura sobre o tema Governança Corporativa e Modelo de Excelência da Gestão;
pesquisa documental em que foram consultadas as publicações técnicas da FNQ®, os
relatórios de gestão e de avaliação do PNQ®, informações disponíveis nos websites do IBGC,
da CVM, da FNQ ® e da Coelce; e pesquisa de campo em que os procedimentos de coleta
foram as entrevistas com a Diretoria Executiva e a aplicação de questionários com um grupo
de colaboradores da empresa. Os resultados da análise comparativa entre os modelos
mundiais de governança e o modelo de governança corporativa da Coelce revelaram que a
empresa mostrou maior proximidade com as características dos modelos alemão e latinoamericano
com aderência de 50% das 10 características catalogadas por Andrade e Rossetti
(2012).Por meio da análise documental dos Relatórios de Avaliação do PNQ® foi possível
constatar um avanço de 40% do total de 40 pontos do item de governança corporativa no
período de 2008 a 2011. Pela pesquisa de campo, concluiu-se que a implementação da
excelência da gestão na Coelce teve, nas diretrizes da governança corporativa, o apoio e a
materialização de ações que contribuíram para melhorias na gestão organizacional.
|
42 |
Polarização intramolecular e separação de carga em estruturas supramolecularesHames, Bruno Clasen January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Física, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:00:24Z (GMT). No. of bitstreams: 1
329096.pdf: 10519634 bytes, checksum: b7f90ad52507cc4cbf22ae154f5af5d2 (MD5)
Previous issue date: 2014 / Estruturas supramoleculares artificiais coletoras de luz são produzidas para reproduzir os mecanismos de transdução de energia luminosa para eletroquímica observados na fotossíntese natural. Dentre elas o protótipo carotenóide(C)-porfirina(P)-fulereno(C60) tem sido o mais estudado. Vários experimentos realizados em tal estrutura, e em outras semelhantes, mostram que o estado fotoexcitado C-1P-C60 decai para o estado de carga separada metaestável C-P.+-C.60- dentro de poucos picossegundos, enquanto que o estado de carga separada final, C.+-P-C.60-, é obtido dentro de centenas de picossegundos. Este trabalho introduz um hamiltoniano de Hückel Estendido polarizável não linear que descreve a dinâmica da carga e o efeito de separação de carga de elétron e buraco em tais tríades por meio de simulações de dinâmica quântica realizadas para o par elétron-buraco fotoexcitado. Os resultados são interpretados com base no efeito de autoconfinamento produzido pela Equação de Schrödinger não linear e esclarecem o papel desempenhado pela polarizabilidade no fenômeno de separação de carga.<br> / Abstract : Artificial light-harvesting supramolecular structures reproduce the light-to-electrochemical energy transduction mechanisms observed in natural photosynthesis. Among them the prototypical carotenoid(C)-porphyrin(P)-fullerene(C60) type of structures have been the most studied. Several experiments performed in such structures, and others alike, have shown that the photoexcited state C-1P-C60 decays to the metastable charge-separated state C - P.+ - C.60- within a few picoseconds, whereas the final charge-separated state, C.+ - P - C.60-, is obtained within hundreds of picoseconds. This work introduces a nonlinear polarizable extended Hückel Hamiltonian that describes the charge dynamics and charge- separation effects in such triads by means of quantum dynamics simulations performed on the photoexcited electron-hole pair. The results are interpreted on the basis of the discrete self-trapping equation and enlighten the role played by the polarizability on charge-separation phenomena.
|
43 |
Responsabilidade social empresarial e comprometimento organizacional: um estudo no setor elétricoNunes, André Luis Loiola Andrade January 2012 (has links)
NUNES, André Luis Loiola Andrade. Responsabilidade social empresarial e comprometimento organizacional: um estudo no setor elétrico. 2012. 98 f. Dissertação (Mestrado) – Universidade Federal do Ceará, Faculdade de Economia, Administração, Atuária e Contabilidade, Programa de Pós-Graduação em Administração e Controladoria, Fortaleza-CE, 2012. / Submitted by Dioneide Barros (dioneidebarros@gmail.com) on 2016-04-18T15:42:35Z
No. of bitstreams: 1
2012_dis_allanunes.pdf: 1935207 bytes, checksum: b7c46ebb9e30579b36d293f969165fd2 (MD5) / Approved for entry into archive by Dioneide Barros (dioneidebarros@gmail.com) on 2016-04-25T13:38:26Z (GMT) No. of bitstreams: 1
2012_dis_allanunes.pdf: 1935207 bytes, checksum: b7c46ebb9e30579b36d293f969165fd2 (MD5) / Made available in DSpace on 2016-04-25T13:38:26Z (GMT). No. of bitstreams: 1
2012_dis_allanunes.pdf: 1935207 bytes, checksum: b7c46ebb9e30579b36d293f969165fd2 (MD5)
Previous issue date: 2012 / Increasingly, the electricity sector has played important economic and social role on the
national scene. Driven by multiple stresses, especially coming from the regulator, ANEEL,
and the association of distributors, ABRADEE, the electricity distribution companies have
modernized their management systems, with consequences for both the public and external to
internal. In this context, corporate social responsibility becomes a competitive advantage for
its potential power to affect a wide range of stakeholders, including employees, in terms of
their engagement. This research seeks to investigate the relationship between social
responsibility and organizational commitment within a utility company, Eletrobras
Distribuição Piauí. About the topic of corporate social responsibility as a parameter, we use
the values issues, Transparency and Governance, and Internal Public Ethos Indicators (2012).
About the issue of organizational commitment use the dimensions affective, instrumental and
normative Meyer and Allen (1991). This is a descriptive, quantitative, conducted by a survey.
The field data will be collected through structured questionnaires, applied to a group of
managers and employees. Data analysis will be performed from descriptive statistics and also
by categorization and content analysis. The survey results seek initially to identify the profile
of the respondent, through the position, length of experience, gender, age, marital status and
education. Second, identify and analyze the current status of social responsibility in the
company in focus. Thirdly, analyze the indicators of affective organizational commitment,
instrumental and normative. Finally, analyze the correlations between indicators of corporate
social responsibility, and indicators of organizational commitment. / Crescentemente, o setor elétrico tem desempenhado relevante papel econômico e social no
cenário nacional. Impulsionadas por múltiplas pressões, em especial advindas da agência
reguladora, ANEEL, e da associação de distribuidoras, ABRADEE, as distribuidoras de
energia elétrica têm modernizado seus sistemas de gestão, com reflexos tanto para o público
externo quanto para o interno. Nesse contexto, a responsabilidade social empresarial torna-se
um diferencial competitivo por seu poder potencial de afetar uma ampla gama de
stakeholders, inclusive os colaboradores, em termos do seu engajamento. Nesta pesquisa,
busca-se investigar as relações entre responsabilidade social e comprometimento
organizacional no âmbito de uma distribuidora de energia elétrica, a Eletrobras Distribuição
Piauí. Sobre o tema da responsabilidade social empresarial, como parâmetro, são apresentados
os subtemas Valores, Transparência e Governança e Público Interno dos Indicadores Ethos.
A respeito do tema do comprometimento organizacional são abordadas as dimensões afetiva,
instrumental e normativa explicitadas por Meyer e Allen. Esta pesquisa é descritiva e
apresenta dados de natureza quantitativa, realizada mediante um survey. Os dados foram
coletados por meio de questionários estruturados, aplicados a um grupo de gestores e
colaboradores. A análise dos dados foi realizada a partir de técnicas estatísticas descritivas e,
também, por meio da categorização e da análise de conteúdo. Os resultados da pesquisa
buscam, inicialmente, identificar o perfil do respondente por meio do cargo, tempo de
experiência, sexo, faixa etária, estado civil e escolaridade e, em segundo lugar, identificar e
analisar o estágio atual das ações de responsabilidade social na empresa em foco. Em terceiro
lugar, considera os indicadores de comprometimento organizacional afetivo, instrumental e
normativo. Por último, analisa as correlações entre os indicadores de responsabilidade social
empresarial e os indicadores de comprometimento organizacional.
|
44 |
Desenvolvimento de compósitos de poliuretano derivado do áleo de mamona com aditivos condutores nanoestruturados de montmorilonita/polipirrol para utilização em blindagem eletromagnéticaVargas, Patricia Cristine January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:44:19Z (GMT). No. of bitstreams: 1
340631.pdf: 2852546 bytes, checksum: 93be31473dfe55365b70319831ca2449 (MD5)
Previous issue date: 2016 / Nesta dissertação foram desenvolvidos compósitos de poliuretano derivado do óleo de mamona (PU) com aditivos condutores nanoestruturados de montmorilonita/polipirrol (MMt-PPy) visando à utilização em blindagem eletromagnética. Os aditivos condutores nanoestruturados foram preparados a partir da polimerização oxidativa in situ do pirrol na presença da montmorilonita (MMt) em uma solução aquosa contendo ácido dodecil benzeno sulfônico (DBSA) como surfactante. O aditivo condutor nanoestruturado foi incorporado na matriz de PU para a obtenção de compósitos de PU/MMt-PPy.DBSA. A fim de realizar um estudo comparativo, foram desenvolvidas blendas de PU contendo como aditivo condutor apenas o polipirrol dopado com DBSA (PPy.DBSA). A morfologia e as propriedades mecânicas, térmicas e elétricas dos compósitos foram avaliadas e comparadas com as blendas contendo apenas PPy.DBSA. Verificou-se que à medida que aumentou-se a concentração mássica do aditivo condutor nanoestruturado, houve um aumento significativo da tensão na ruptura (s), e do módulo de elasticidade (E) e tenacidade, indicando que o aditivo MMt-PPy.DBSA atuou como agente de reforço. Além disso, verificou-se que a condutividade elétrica apresentou um aumento de até 15 ordens de grandeza com relação ao PU puro, chegando a valores próximos ao do aditivo condutor nanoestruturado puro. Os compósitos também apresentaram atenuação da radiação eletromagnética, sendo que a magnitude da resposta foi influenciada pela fração mássica de MMt-PPy.DBSA e espessura das amostras, chegando-se a um valor máximo de -77 dB para compósitos com 25%m de MMt-PPy.DBSA e 8 mm de espessura. A partir deste estudo foi possível concluir que os compósitos apresentaram melhor dispersão e distribuição do aditivo na matriz de PU, melhores propriedades mecânicas, maiores valores de condutividade elétrica e maior eficiência de blindagem quando comparado às blendas. Este comportamento está relacionado à morfologia lamelar do aditivo condutor nanoestruturado, que apresenta maior razão de aspecto, possibilitando a formação de uma estrutura intercalada/parcialmente esfoliada, com grande interação entre aditivo e matriz. Desta forma, os compósitos de PU/MMt-PPy.DBSA desenvolvidos neste trabalho são materiais promissores para serem utilizados na blindagem eletromagnética.<br> / Abstract: In this work it was developed polyurethane composites derived from castor oil (PU) with nanostructured conductive additives of montmorillonite/polypyrrole (MMt-PPy) with the purpose of using in electromagnetic shielding. The nanostructured conductive additives were prepared from the oxidative in situ polymerization of pyrrole in the presence of montmorillonite (MMt) in an aqueous solution containing dodecyl benzene sulfonic acid (DBSA) as surfactant. Different concentrations of the nanostructured conductive additives were incorporated into polyurethane matrix derived from castor oil (PU), for obtaining composites of PU/MMt-PPy.DBSA. In order to perform a comparative study, PU blends containing neat polypyrrole doped with DBSA (PPy.DBSA) as conductive additive were developed. The morphology and the mechanical, thermal and electrical properties of the composites were evaluated and compared with blends containing neat PPy.DBSA. It was found that when the mass concentration of the nanostructured conductive additive was increased, there was a significant increase in the tensile stress (s) and modulus of elasticity (E), indicating that the additive MMt-PPy.DBSA acted as a reinforcing agent. Furthermore, it was found that the electrical conductivity increased by up to 14 orders of magnitude, when compared to pure PU, reaching values close to the pure nanostructured conductive additive. The composites also showed attenuation of the electromagnetic radiation, and the magnitude of the response was influenced by the mass fraction of MMt-PPy.DBSA and thickness of the samples, reaching a maximum value of -77 dB for composites containing 25%m MMt-PPy.DBSA and 8 mm of thickness. From this study, it was concluded that the composites showed better distribution and dispersion of the additive in PU matrix, better mechanical properties, higher electrical conductivity values and higher shielding effectiveness when compared to blends. This behavior is related to the lamellar morphology of the nanostructured conductive additive, which has a higher aspect ratio, allowing the formation of an intercalated / partially exfoliated structure with a strong interaction between the additive and matrix. Thus, the composites PU/MMt-PPy.DBSA developed in this study are promising materials for electromagnetic shielding applications.
|
45 |
Contribuição à modelagem de transformadores operando em condições nominais submetidos a surtosJanuário, Marconi January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T12:49:33Z (GMT). No. of bitstreams: 1
338904.pdf: 15905021 bytes, checksum: ba12b4d273168e764008021204b3e07e (MD5)
Previous issue date: 2015 / Esta tese apresenta uma modelagem de transformadores que,estando operando em condições nominais, sejam submetidos a surtos. Foram utilizados para a modelagem dados de respostas em frequências e de ensaios sob condições nominais. O modelo proposto representa respostas em frequência de impedâncias de transformadores sem carga e que estejam operando sob condições nominais. Ainda, foi proposto um modelo que, além de descrever respostas em frequência de impedâncias em aberto e sob condições nominais, representa, também, o comportamento de respostas em frequências de relações de tensão. Os modelos e as metodologias utilizados para a determinação de valores de parâmetros propostos foram validados através de transformadores com diferentes níveis de tensão e potência. As validações foram realizadas no domínio da frequência e do tempo. Apresentam-se exemplos de aplicações dos modelos, por meio de simulações numéricas.<br> / Abstract : The thesis presents a modeling of transformers, which operatingin steady state and submitted to surges. In the modeling useddata from frequency response and from tests under nominal conditionswere taken. The proposed model represents the frequencyresponse of a transformer at no load and under nominal conditions.Furthermore, it is also proposed a model that representsthe voltage frequency responses between transformer terminals.The models and the methodologies to determining the parametervalues were validated through transformers with different voltagelevels and power. Validations of the models are carried out inthe frequency and time domains. Examples of applications of themodels are shown by numerical simulations.
|
46 |
Impedância bioelétrica na ocorrência da pré-eclâmpsiaSilva, Elaine Gomes da [UNESP] 28 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:39Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-08-28Bitstream added on 2014-06-13T21:07:53Z : No. of bitstreams: 1
silva_eg_dr_botfm.pdf: 973178 bytes, checksum: 4a8313adf342022e0a48ef10b96e7f10 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Analisar possíveis associações entre resistência e reactância, avaliadas pela análise de impedância bioelétrica (BIA), no primeiro, segundo e terceiro trimestres de gestação, e ocorrência de pré-eclâmpsia; identificar qual o momento mais precoce da associação. Coorte prospectiva. Hospital das Clinicas da Faculdade de Medicina de Botucatu/Unesp. 380 gestantes acompanhadas no Serviço. As gestantes foram submetidas à BIA, no primeiro (até 14 semanas), segundo (15 a 28 semanas) e terceiro (29 a41 semanas) trimestres, para avaliação dos valores de resistência e reactância. Considerou-se o desenvolvimento de hipertensão arterial, após a 20ª semana, com ou sem proteinúria, respectivamente, Pré-eclâmpsia (PE) e Hipertensão Gestacional (HG). Foi realizada a análise estatística através teste T de student e do Odds-Ratio considerando p<0,05. No primeiro trimestre a média da resistência e reactância do grupo PE (508Ω;57Ω) foi significativamente menor que a observada no grupo normotenso (580Ω;66Ω). No segundo trimestre as médias de resistência e reactância no grupo PE, respectivamente, (502Ω e 53Ω), foram menores significativamente do que as encontradas no grupo normotenso (566Ω e 57Ω). No terceiro trimestre foram também significativamente menores quando comparadas com o grupo normotenso (452 Ω e 47 Ω). No primeiro trimestre o Odds ratio (OR) para a resistência foi de 0,99 (IC 0,98 – 1,0) com p=0,002 e reactância foi de 0,93 (IC 0,85- 1,01) com p=0,07. No Segundo trimestre o OR foi de 0,99 (IC 0,98-0,99) e p=0,001 e a reactância o OR foi de 0,95 (IC=0,9-1,00) com p=0,05. No terceiro trimestre o OR foi de foi de 0,99 (IC 0,98-0,99) e p=0,0010 para resistência e de 0,93 (IC 0,88 – 0,98) e p=0,01 para reactância. A bioimpedância mostrou associação através da resistência tanto no primeiro quanto no segundo... / To analyze possible associations between resistance and reactance, as evaluated by electrical impedance analysis (BIA) in the first, second and third pregnancy trimesters, and preeclampsia occurrence; to identify the earliest moment of association. Prospective cohort. Botucatu School of Medicine University Hospital/Unesp. Population: 380 pregnant women attended to by the Service. The pregnant women underwent BIA in the first (up to 14 weeks), second (15 to 28 weeks) and third (29 to 41 weeks) trimesters for evaluation of resistance and reactance values. The development of arterial hypertension, after the 20th week, with or without proteinuria, respectively, Preeclampsia (PE) and Gestational Hypertension (GH) was considered. Statistical analysis by Odds-Ratio was performed considering p<0.05. In the first trimester, the resistance and reactance means in the PE group (508Ω;57Ω) were significantly lower than those observed in the healthy group (580Ω;66Ω). In the second trimester, the resistance and reactance means in the PE group, respectively (502Ω and 53Ω), were lower than those found in the healthy group (566Ω and 57Ω). In the third trimester were lower than than those found in the healthy group (452 Ω e 47 Ω). In the first trimester, the Odds ratio (OR) for resistance was 0.99 (CI 0.98 – 1.0) with p=0.002, and reactance was 0.93 (CI 0.85-1.01) with p=0.07. In the second trimester, OR was 0.99 (CI 0.98-0.99) and p=0.001, and for reactance, OR was 0.95 (CI=0.9-1.00) with p=0.05. In the third trimester, the Odds ratio (OR) for resistance was (IC 0,98-0,99) with p=0,0010 and 0,93 (IC 0,88 – 0,98) with p=0,01 for reactance. Bioimpedance showed association by means of resistance both in the first... (Complete abstract click electronic access below)
|
47 |
Cooperativismo e regulação: análise de desempenho das cooperativas de eletrificação do sul do BrasilCardoso, João Vanio Mendonça January 2018 (has links)
Dissertação apresentada ao Programa de Pós-Graduação em Desenvolvimento Socioeconômico da Universidade do Extremo Sul Catarinense (UNESC), como requisito parcial para a obtenção do título de Mestre em Desenvolvimento Socioeconômico. / No Brasil, as Cooperativas de Eletricidade (CEs) surgiram da necessidade de levar energia elétrica às áreas rurais de baixa densidade demográfica. A partir da década de 1990, o setor elétrico brasileiro passou por grandes mudanças, pelas quais foi criada a ANEEL, que, na década seguinte, impôs um processo de regularização das CEs com base no novo modelo do setor. Esse processo ocasionou a redução do número de CEs e inseriu a maioria das restantes no ambiente regulado do setor elétrico nacional. Nesse ambiente, o poder concedente aplica mecanismos de controle e interferências externas, como forma de que as empresas sejam geridas de forma eficiente. Portanto, o acompanhamento, controle, avaliação e aprimoramento no processo de gestão têm grande importância no desempenho das CEs. Diante disso, o presente estudo teve por objetivo analisar os desempenhos econômico-financeiros e operacional das CEs do Sul do Brasil, por meio de clusters de acordo com suas semelhanças e diferenças. Quanto ao objeto de estudo, ele está composto pelas CEs do sul do Brasil que estão na condição de concessionária ou permissionária. Os dados analisados foram relativos aos períodos de 2012 a 2016. Sob o aspecto metodológico, este estudo é de natureza aplicada e está amparado pela abordagem quantitativa com fins descritivos. Como estratégia de pesquisa, realizou-se um estudo do tipo levantamento ou survey. Como técnica de investigação, utilizou-se a análise multivariada de dados. Os dados apontaram que existem três grupos bem definidos quanto às características e quanto ao desempenho econômico-financeiro e operacional: Cluster1) CEs com grandes consumidores e poucos colaboradores com desempenho intermediário; Cluster2) CEs com pequenos consumidores e muitos colaboradores com desempenho superior; Cluster3) CEs com grandes consumidores e muitos colaboradores com desempenho inferior. Observou-se também uma proximidade no desempenho dos grupos intermediário e inferior. Conclui-se que as CEs são, na sua maioria, organizações pequenas, mas nem por isso apresentam desempenho tímido. Além disso, o mercado é composto por pequenos ou grandes consumidores, e a quantidade de colaboradores é também um forte determinante do desempenho econômico-financeiro e operacional nas CEs.
|
48 |
Identificação, monitoramento e previsão de tempestades elétricasKleina, Mariana January 2015 (has links)
Orientador : Prof. Dr. Luiz Carlos Matioli / Tese (doutorado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Métodos Numéricos em Engenharia. Defesa: Curitiba, 10/12/2015 / Inclui referências : f. 103-107 / Área de concentração : Programação matemática / Resumo: Este trabalho tem por objetivo propor um sistema de identificação, monitoramento e previsão de tempestades elétricas em uma região de linha de transmissão de energia do Brasil utilizando apenas informações de descargas atmosféricas. Na etapa de identificação das tempestades é utilizada clusterização espacial/temporal das descargas, para o monitoramento são realizadas conexões entre clusters de acordo com a velocidade de deslocamento dos núcleos das tempestades e finalmente a previsão uma hora à frente é obtida por meio de extrapolação de dados. As variáveis das tempestades elétricas acompanhadas e previstas são: posição central (latitude e longitude), número médio de descargas por hora, distribuição espacial das descargas dentro das tempestades e média do valor absoluto do pico de corrente de descargas que compõem as tempestades. O sistema é calibrado por meio da otimização de um problema irrestrito baseado em índices de monitoramento e previsão. Exemplos práticos são apresentados para a região piloto, onde diversos gráficos ilustram o produto do sistema proposto. Palavras-chave: Análise de Agrupamento. Convergent Data Sharpening. Descargas Atmosféricas. Tempestades Elétricas. Previsão à Curto Prazo. / Abstract: This work aims to propose a system of identification, monitoring and forecasting of electrical storms on a region of Brazilian power transmission line using lightning information only. In the step of storms identification is used spatial/temporal lightning clustering, to monitoring are performed connections between clusters according to the displacement speed of the storms cores and finally the forecast one hour ahead is obtained by data extrapolation. The monitored and forecasted variables of the electrical storms are: center position (latitude and longitude), average number of lightning per hour, spatial distribution of lightning into the storms and average of the absolute value of the peak current of lightning that comprise the storms. The system is calibrated by optimizing an unrestricted problem based on monitoring and forecasting indexes. Practical examples are presented to the pilot region and several graphs illustrate the proposed system product. Key-words: Cluster Analysis. Convergent Data Sharpening. Lightning Strokes. Electrical Storms. Forecast Short Term.
|
49 |
O papel da energia de polarização no transporte de carga em sistemas moleculares orgânicos e um modelo para o experimento de fotovoltagem de superfícieTonezer, Camila 23 October 2012 (has links)
Resumo: Esta tese será apresentada em duas partes: na primeira delas vamos mostrar o estudo da densidade de estados e da correlação energética em dois modelos para sistemas orgânicos desordenados. O transporte de portadores de carga nesses sistemas é caracterizado pela localização dos estados eletrônicos e pela desordem posicional e energética desses estados. A interação dos portadores de carga com os dipolos elétricos induzidos nas moléculas vizinhas, combinada a desordem posicional, dá origem a desordem energética. O primeiro sistema a ser tratado e baseado em uma rede cúbica simples, com adição de um pequeno vetor de deslocamento em cada sítio, sendo que este vetor de deslocamento é distribuído de acordo com uma distribuição Gaussiana. O segundo sistema é baseado em uma distribui¸c˜ao de esferas rígidas, geradas através de uma simulação de Monte Carlo. Nos dois casos, as energias dos sítios são definidas pela interação dos portadores de carga com dipolos elétricos induzidos nas moléculas vizinhas. Também modelamos o experimento de tempo de vôo usando uma equação mestra para obter a mobilidade em um sistema representado por esferas rígidas; com as energias devido a interação das cargas com dipolos elétricos induzidos. Analisamos a dependência da mobilidade com o campo elétrico aplicado. A segunda parte desta tese abordará o estudo do experimento do transiente de foto voltagem de superfície em TiO2 nano estruturado contendo moléculas de corantes adsorvidas na superfície. Um modelo usando uma equação mestra foi construído para descrever esse experimento. Este modelo envolve fenômenos de difusão de elétrons, recombinação de elétrons E íons bem como a presença de potencial eletrostático devido aos elétrons e íons.
|
50 |
Previsão de alerta de raios utilizando lógica nebulosa e campo elétrico atmosféricoIgarashi, Adriel Yoshio Santos 14 December 2012 (has links)
Resumo: O trabalho apresenta uma metodologia inovadora baseada em Lógica Nebulosa para a geração de alertas de descargas elétricas atmosféricas. Essa metodologia utiliza informações sobre o campo elétrico atmosférico, a dinâmica dos eventos de descargas elétricas ao redor do local de interesse e informações sobre a distância de incidência dos relâmpagos. Essas informações foram combinadas através da Lógica Nebulosa a qual teve suas funções de pertinência otimizadas através de Algoritmos Genéticos e Algoritmos de Evolução Diferencial. A metodologia proposta foi testada em um estudo de caso para a geração de alertas de raios em uma refinaria de petróleo. Os resultados foram comparados entre si e com outros sistemas através dos indicadores de desempenho criados para esse fim. A partir desses indicadores e da função objetivo com múltiplos parâmetros pode-se concluir que esta nova metodologia possui maiores vantagens na geração de alertas de incidências de descargas elétricas atmosféricas.
|
Page generated in 0.0673 seconds