• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement et validation d'un instrument de mesure de l'indépendance dans les activités instrumentales basé sur les fonctions exécutives suite à un traumatisme crânien

Bottari, Carolina January 2007 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
2

Étude de la fidélité des paramètres de la raideur passive de l'articulation de la hanche et analyse de leurs relations avec les mesures cliniques

Brière, Anabèle January 2004 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
3

Validité et fidélité des mesures de mobilité de la ceinture scapulaire

Kovacs, Stéphanie 12 1900 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal. / La ceinture scapulaire (CS) est une région du complexe de l'épaule fréquemment évaluée par les physiothérapeutes. Le premier objectif de cette étude était d'examiner la fidélité de l’évaluation des mouvements actifs d'élévation, de rétraction et de protraction de la CS avec les méthodes suivantes: par estimation visuelle, avec un goniomètre et un ruban à mesurer. Le deuxième objectif consistait à déterminer la validité concomitante des mesures prises avec le goniomètre et le ruban à mesurer, en comparant l'amplitude articulaire obtenue avec celle estimée à partir de marqueurs infrarouges placés sur le sujet. La mobilité active de trente sujets sains (quinze femmes, quinze hommes) a été évaluée bilatéralement à deux occasions, par deux physiothérapeutes de cinq et quinze ans d'expérience clinique. Pour évaluer la validité concomitante, des marqueurs ont ensuite été placés sur le sujet et la position de ceux-ci a été enregistrée avec un système d'analyse tridimensionnelle (Optotrak 3020) lors des mouvements d'élévation, de protraction et de rétraction. Le kappa (K) a été utilisé pour établir la fidélité des mesures par estimation visuelle alors que la théorie de la généralisabilité a permis de déterminer la fidélité des mesures prises avec le goniomètre et le ruban à mesurer. Cette théorie permet de calculer des indioes de fidélité (coefficients de dépendabilité (<()) et des erreurs standards de mesure (ESMs). La validité concomitante a été évaluée en établissant l'association (coefficient de Pearson, r) entre les mesures cliniques et expérimentales. Par estimation visuelle, la fidélité inter-juges et test-retest variait de pauvre à substantielle pour tous les mouvements de la CS (K = -0.09 à 0.65). La fidélité intra-juge était plus élevée pour la physiothérapeute la moins expérimentée (K = 0.71 à 1.00). La fidélité des mesures goniométriques était pauvre pour tous les mouvements, bien qu'elle était plus acceptable pour l'élévation (<)) = 0.55 à 0.66, ESMs = 3.6° à 4.3°). Les mesures les plus fidèles étaient celles prises avec le ruban, pour l'élévation (<(> = 0.74 à 0.77, ESMs = 1.1 à 1.2 cm) etla rétraction (<)) = 0.64 à 0.71, ESMs = 0.7 à 0.8 cm). La validité concomitante avec le système Optotrak était la plus élevée pour l'élévation, avec les deux méthodes (r = 0.63-0.84). La rétraction était seulement valide avec le goniomètre (r = 0.48 à 0.60). Avec le goniomètre et le ruban à mesurer, la protraction n'était ni fidèle, ni valide. Cette étude a démontré que l'élévation était le mouvement le plus fidèle et le plus valide. Il pourra donc être utilisé par les cliniciens dans l'examen de la CS. Des recherches chez des sujets souffrant de pathologies de l'épaule pourront donner des informations additionnelles sur l’évaluation de cette région.
4

La généralisabilité d'erreurs conceptuelles dans le cadre de l'évaluation formative de l'apprentissage de concepts

Girard, Richard 25 April 2018 (has links)
Depuis quelques années, on peut noter une tendance nouvelle qui consiste a mettre davantage l'accent sur la valeur diagnostique des épreuves de rendement scolaire. En effet, l'idée d'une épreuve de rendement dont le but n'est pas seulement de déterminer le niveau de compétence d'un étudiant mais aussi d'identifier les difficultés qu'a pu rencontrer cet étudiant en cours d'apprentissage doit être considérée comme une innovation. Sans doute, plusieurs motifs peuvent être évoqués pour expliquer cette pratique nouvelle. Entre autres, le désir d'améliorer l'efficacité de l'apprentissage a probablement incité les responsables de l'évaluation du rendement scolaire à mettre davantage l'accent sur les difficultés que peut rencontrer un étudiant en cours d'apprentissage. Ce nouveau rôle de l'épreuve de rendement scolaire s'inscrit plutôt dans le contexte de l'évaluation formative que dans celui de l'évaluation diagnostique telle que définie par Bloom, Hasting et Madaus (1974). Selon ces auteurs, l'évaluation diagnostique joue un double rôle: classer l'étudiant à l'endroit le plus approprié dans une séquence de cours ou d'unités d'apprentissage et déterminer les causes ou les circonstances susceptibles d'expliquer les difficultés persistantes d'apprentissage rencontrées par un étudiant. Ces deux fonctions se distinguent surtout de la fonction diagnostique remplie par l'évaluation formative quant au moment où intervient le diagnostic et quant à la nature même des difficultés rencontrées. L'évaluation diagnostique s'effectue habituellement avant ou après plusieurs unités d'enseignement alors que l'évaluation formative se fait en cours d'apprentissage. Le diagnostic effectué dans le cadre de l'évaluation formative porte sur des difficultés temporaires qu'éprouve un étudiant alors que l'évaluation diagnostique intervient lorsqu'un étudiant manifeste des difficultés persistantes et ce, même si un enseignement correctif supposément adéquat a été dispensé. Quoique l'utilité de construire un instrument de mesure à caractère diagnostique dans le cadre de l'évaluation formative est reconnue, il semble qu'une telle entreprise soit encore à l'état de projet. A quelles exigences doit répondre un tel instrument visant à déceler les erreurs qu'est susceptible de rencontrer un étudiant en cours d'apprentissage? Quelles sont les causes de ces difficultés et comment les identifier? Quels correctifs sont les plus appropriés pour pallier aux difficultés rencontrées? La réponse à ces questions nous semble étroitement reliée à la valeur diagnostique et prescriptive d'un instrument de mesure construit dans le cadre d'une évaluation formative. / Québec Université Laval, Bibliothèque 2014
5

Développement et validation d’un outil clinique pour l’analyse quantitative de la posture auprès de personnes atteintes d’une scoliose idiopathique

Fortin, Carole 06 1900 (has links)
La scoliose idiopathique (SI) est une déformation tridimensionnelle (3D) de la colonne vertébrale et de la cage thoracique à potentiel évolutif pendant la croissance. Cette déformation 3D entraîne des asymétries de la posture. La correction de la posture est un des objectifs du traitement en physiothérapie chez les jeunes atteints d’une SI afin d’éviter la progression de la scoliose, de réduire les déformations morphologiques et leurs impacts sur la qualité de vie. Les outils cliniques actuels ne permettent pas de quantifier globalement les changements de la posture attribuables à la progression de la scoliose ou à l’efficacité des interventions thérapeutiques. L’objectif de cette thèse consiste donc au développement et à la validation d’un nouvel outil clinique permettant l’analyse quantitative de la posture auprès de personnes atteintes d’une SI. Ce projet vise plus spécifiquement à déterminer la fidélité et la validité des indices de posture (IP) de ce nouvel outil clinique et à vérifier leur capacité à détecter des changements entre les positions debout et assise. Suite à une recension de la littérature, 34 IP représentant l’alignement frontal et sagittal des différents segments corporels ont été sélectionnés. L’outil quantitatif clinique d’évaluation de la posture (outil 2D) construit dans ce projet consiste en un logiciel qui permet de calculer les différents IP (mesures angulaires et linéaires). L’interface graphique de cet outil est conviviale et permet de sélectionner interactivement des marqueurs sur les photographies digitales. Afin de vérifier la fidélité et la validité des IP de cet outil, la posture debout de 70 participants âgés entre 10 et 20 ans atteints d'une SI (angle de Cobb: 15º à 60º) a été évaluée à deux occasions par deux physiothérapeutes. Des marqueurs placés sur plusieurs repères anatomiques, ainsi que des points de référence anatomique (yeux, lobes des oreilles, etc.), ont permis de mesurer les IP 2D en utilisant des photographies. Ces mêmes marqueurs et points de référence ont également servi au calcul d’IP 3D obtenus par des reconstructions du tronc avec un système de topographie de surface. Les angles de Cobb frontaux et sagittaux et le déjettement C7-S1 ont été mesurés sur des radiographies. La théorie de la généralisabilité a été utilisée pour déterminer la fidélité et l’erreur standard de la mesure (ESM) des IP de l’outil 2D. Des coefficients de Pearson ont servi à déterminer la validité concomitante des IP du tronc de l’outil 2D avec les IP 3D et les mesures radiographiques correspondantes. Cinquante participants ont été également évalués en position assise « membres inférieurs allongés » pour l’étude comparative de la posture debout et assise. Des tests de t pour échantillons appariés ont été utilisés pour détecter les différences entre les positions debout et assise. Nos résultats indiquent un bon niveau de fidélité pour la majorité des IP de l’outil 2D. La corrélation entre les IP 2D et 3D est bonne pour les épaules, les omoplates, le déjettement C7-S1, les angles de taille, la scoliose thoracique et le bassin. Elle est faible à modérée pour la cyphose thoracique, la lordose lombaire et la scoliose thoraco-lombaire ou lombaire. La corrélation entre les IP 2D et les mesures radiographiques est bonne pour le déjettement C7-S1, la scoliose et la cyphose thoracique. L’outil est suffisamment discriminant pour détecter des différences entre la posture debout et assise pour dix des treize IP. Certaines recommandations spécifiques résultents de ce projet : la hauteur de la caméra devrait être ajustée en fonction de la taille des personnes; la formation des juges est importante pour maximiser la précision de la pose des marqueurs; et des marqueurs montés sur des tiges devraient faciliter l’évaluation des courbures vertébrales sagittales. En conclusion, l’outil développé dans le cadre de cette thèse possède de bonnes propriétés psychométriques et permet une évaluation globale de la posture. Cet outil devrait contribuer à l’amélioration de la pratique clinique en facilitant l’analyse de la posture debout et assise. Cet outil s’avère une alternative clinique pour suivre l’évolution de la scoliose thoracique et diminuer la fréquence des radiographies au cours du suivi de jeunes atteints d’une SI thoracique. Cet outil pourrait aussi être utile pour vérifier l’efficacité des interventions thérapeutiques sur la posture. / Idiopathic scoliosis (IS) is characterized by three-dimensional (3D) deformity of the spine and rib cage which can increase during growth. The morphologic changes of the trunk result in posture asymmetries. Correction of posture is an important goal of physiotherapy interventions among persons with IS to prevent scoliosis progression, to reduce morphologic deformities and their impact on quality of life. Currently, there are no tools that globally quantify changes in posture that may be attributable to scoliosis progression or to treatment effectiveness, that are usable in a clinical setting. The objective of this thesis was thus to develop and validate a new clinical quantitative posture assessment tool among persons with IS. More specifically, this project aims to determine reliability and concurrent validity of posture indices (PI) of this new tool and to verify their capacity to detect changes between standing and sitting positions. We conducted a literature review and selected 34 PI representing frontal and sagittal alignment of the different body segments. We constructed a software-based quantitative posture assessment tool to calculate different PI (angular and linear measurements). The software has a user-friendly graphical interface and allows calculation of PI from a set of markers selected interactively on digital photographs. For the reliability and validity studies, standing posture of 70 participants aged 10 to 20 years old with IS (Cobb angle: 15º to 60º) was assessed on two occasions by two physiotherapists. Markers placed on several bony landmarks as well as natural reference points (eyes, ear lobe, etc.) were used to measure the PI from photographs with the 2D tool and to calculate 3D PI obtained from trunk reconstructions with a surface topography system. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The generalizability theory was used to estimate the reliability and standard error of measurement (SEM) of PI of the 2D tool. Pearson correlation coefficients served to estimate concurrent validity of the 2D trunk PI with corresponding 3D PI and with those obtained from radiographs. Fifty participants were assessed for the comparative study between standing and sitting positions. We compared the average values of each PI in standing and long sitting positions using paired t-tests. Our results show a good level of reliability for the majority of PI of the 2D tool. Correlation between 2D and 3D PI was good for shoulder, scapula, trunk list, waist angles, thoracic scoliosis and pelvis but fair to moderate for thoracic kyphosis, lumbar lordosis and thoracolumbar or lumbar scoliosis. The correlation between 2D and radiograph measurements was good for trunk list, thoracic scoliosis and thoracic kyphosis. Our tool can detect differences between standing and sitting posture for ten out of thirteen PI. A few recommendations specific to this work are: camera height should be adjusted according to the subject’s height; training of judges is important to maximize accuracy in placement of markers; and measurement of sagittal vertebral curves may be facilitated by using markers mounted on pins. In conclusion, the tool developed in this thesis has good psychometric properties to evaluate posture. This tool should contribute to clinical practice by facilitating the analysis of standing and sitting posture. This tool may also be a good alternative to monitor thoracic scoliosis progression in a clinical setting and may contribute to a reduction in the use of x-rays in the follow-up of youths with thoracic IS. It may also be useful to verify the effectiveness of therapeutic interventions on posture.
6

Développement et validation d’un outil clinique pour l’analyse quantitative de la posture auprès de personnes atteintes d’une scoliose idiopathique

Fortin, Carole 06 1900 (has links)
La scoliose idiopathique (SI) est une déformation tridimensionnelle (3D) de la colonne vertébrale et de la cage thoracique à potentiel évolutif pendant la croissance. Cette déformation 3D entraîne des asymétries de la posture. La correction de la posture est un des objectifs du traitement en physiothérapie chez les jeunes atteints d’une SI afin d’éviter la progression de la scoliose, de réduire les déformations morphologiques et leurs impacts sur la qualité de vie. Les outils cliniques actuels ne permettent pas de quantifier globalement les changements de la posture attribuables à la progression de la scoliose ou à l’efficacité des interventions thérapeutiques. L’objectif de cette thèse consiste donc au développement et à la validation d’un nouvel outil clinique permettant l’analyse quantitative de la posture auprès de personnes atteintes d’une SI. Ce projet vise plus spécifiquement à déterminer la fidélité et la validité des indices de posture (IP) de ce nouvel outil clinique et à vérifier leur capacité à détecter des changements entre les positions debout et assise. Suite à une recension de la littérature, 34 IP représentant l’alignement frontal et sagittal des différents segments corporels ont été sélectionnés. L’outil quantitatif clinique d’évaluation de la posture (outil 2D) construit dans ce projet consiste en un logiciel qui permet de calculer les différents IP (mesures angulaires et linéaires). L’interface graphique de cet outil est conviviale et permet de sélectionner interactivement des marqueurs sur les photographies digitales. Afin de vérifier la fidélité et la validité des IP de cet outil, la posture debout de 70 participants âgés entre 10 et 20 ans atteints d'une SI (angle de Cobb: 15º à 60º) a été évaluée à deux occasions par deux physiothérapeutes. Des marqueurs placés sur plusieurs repères anatomiques, ainsi que des points de référence anatomique (yeux, lobes des oreilles, etc.), ont permis de mesurer les IP 2D en utilisant des photographies. Ces mêmes marqueurs et points de référence ont également servi au calcul d’IP 3D obtenus par des reconstructions du tronc avec un système de topographie de surface. Les angles de Cobb frontaux et sagittaux et le déjettement C7-S1 ont été mesurés sur des radiographies. La théorie de la généralisabilité a été utilisée pour déterminer la fidélité et l’erreur standard de la mesure (ESM) des IP de l’outil 2D. Des coefficients de Pearson ont servi à déterminer la validité concomitante des IP du tronc de l’outil 2D avec les IP 3D et les mesures radiographiques correspondantes. Cinquante participants ont été également évalués en position assise « membres inférieurs allongés » pour l’étude comparative de la posture debout et assise. Des tests de t pour échantillons appariés ont été utilisés pour détecter les différences entre les positions debout et assise. Nos résultats indiquent un bon niveau de fidélité pour la majorité des IP de l’outil 2D. La corrélation entre les IP 2D et 3D est bonne pour les épaules, les omoplates, le déjettement C7-S1, les angles de taille, la scoliose thoracique et le bassin. Elle est faible à modérée pour la cyphose thoracique, la lordose lombaire et la scoliose thoraco-lombaire ou lombaire. La corrélation entre les IP 2D et les mesures radiographiques est bonne pour le déjettement C7-S1, la scoliose et la cyphose thoracique. L’outil est suffisamment discriminant pour détecter des différences entre la posture debout et assise pour dix des treize IP. Certaines recommandations spécifiques résultents de ce projet : la hauteur de la caméra devrait être ajustée en fonction de la taille des personnes; la formation des juges est importante pour maximiser la précision de la pose des marqueurs; et des marqueurs montés sur des tiges devraient faciliter l’évaluation des courbures vertébrales sagittales. En conclusion, l’outil développé dans le cadre de cette thèse possède de bonnes propriétés psychométriques et permet une évaluation globale de la posture. Cet outil devrait contribuer à l’amélioration de la pratique clinique en facilitant l’analyse de la posture debout et assise. Cet outil s’avère une alternative clinique pour suivre l’évolution de la scoliose thoracique et diminuer la fréquence des radiographies au cours du suivi de jeunes atteints d’une SI thoracique. Cet outil pourrait aussi être utile pour vérifier l’efficacité des interventions thérapeutiques sur la posture. / Idiopathic scoliosis (IS) is characterized by three-dimensional (3D) deformity of the spine and rib cage which can increase during growth. The morphologic changes of the trunk result in posture asymmetries. Correction of posture is an important goal of physiotherapy interventions among persons with IS to prevent scoliosis progression, to reduce morphologic deformities and their impact on quality of life. Currently, there are no tools that globally quantify changes in posture that may be attributable to scoliosis progression or to treatment effectiveness, that are usable in a clinical setting. The objective of this thesis was thus to develop and validate a new clinical quantitative posture assessment tool among persons with IS. More specifically, this project aims to determine reliability and concurrent validity of posture indices (PI) of this new tool and to verify their capacity to detect changes between standing and sitting positions. We conducted a literature review and selected 34 PI representing frontal and sagittal alignment of the different body segments. We constructed a software-based quantitative posture assessment tool to calculate different PI (angular and linear measurements). The software has a user-friendly graphical interface and allows calculation of PI from a set of markers selected interactively on digital photographs. For the reliability and validity studies, standing posture of 70 participants aged 10 to 20 years old with IS (Cobb angle: 15º to 60º) was assessed on two occasions by two physiotherapists. Markers placed on several bony landmarks as well as natural reference points (eyes, ear lobe, etc.) were used to measure the PI from photographs with the 2D tool and to calculate 3D PI obtained from trunk reconstructions with a surface topography system. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The generalizability theory was used to estimate the reliability and standard error of measurement (SEM) of PI of the 2D tool. Pearson correlation coefficients served to estimate concurrent validity of the 2D trunk PI with corresponding 3D PI and with those obtained from radiographs. Fifty participants were assessed for the comparative study between standing and sitting positions. We compared the average values of each PI in standing and long sitting positions using paired t-tests. Our results show a good level of reliability for the majority of PI of the 2D tool. Correlation between 2D and 3D PI was good for shoulder, scapula, trunk list, waist angles, thoracic scoliosis and pelvis but fair to moderate for thoracic kyphosis, lumbar lordosis and thoracolumbar or lumbar scoliosis. The correlation between 2D and radiograph measurements was good for trunk list, thoracic scoliosis and thoracic kyphosis. Our tool can detect differences between standing and sitting posture for ten out of thirteen PI. A few recommendations specific to this work are: camera height should be adjusted according to the subject’s height; training of judges is important to maximize accuracy in placement of markers; and measurement of sagittal vertebral curves may be facilitated by using markers mounted on pins. In conclusion, the tool developed in this thesis has good psychometric properties to evaluate posture. This tool should contribute to clinical practice by facilitating the analysis of standing and sitting posture. This tool may also be a good alternative to monitor thoracic scoliosis progression in a clinical setting and may contribute to a reduction in the use of x-rays in the follow-up of youths with thoracic IS. It may also be useful to verify the effectiveness of therapeutic interventions on posture.
7

Validation de la reproductibilité d’outils de mesure de la fraction d’éjection du ventricule gauche en médecine nucléaire

Arsenault, Frédéric 05 1900 (has links)
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle. / Left ventricular ejection fraction is an excellent indicator of cardiac function. Many invasive and non-invasive techniques can be used for its assessment: angiography, echocardiography, cardiac MRI, computed tomography of the heart, multigated radionuclide angiography and myocardial perfusion imaging. More than 40 years of scientific publication praise the multigated radionuclide angiography for its execution speed, its availability, its low cost and intrarater and interrater reproducibility. The left ventricular ejection fraction was calculated twice for 47 patients, using two raw data acquisitions, two technologists and three software platforms: one fully manual, one semi-automatic and one fully automatic. In general, the automatic and semi-automatic methods showed greater reproducibility, a smaller standard error of measurement and minimal detectable change than the manual method, whereas the manual method systematically gave a significantly lower quality of result. It was the only technique that showed significant intrarater difference, and its standard error of measurement and minimal detectable change were 40% to 50% higher than those of automatic and semi-automatic methods. Even though all three techniques are all excellent and reliable options, reliability coefficient estimations were superior using automatic and semi-automatic methods as compared to the manual method.
8

The Nursing Intensity Critical Care Questionnaire (NICCQ) : Validation Study in Cardiac Surgery Patients

Champigny, Shawn 04 1900 (has links)
No description available.

Page generated in 0.064 seconds