• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Davi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
2

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Letícia Resende Davi 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
3

Efeito de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio na superfície da liga metálica de cobalto cromo / Effect of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride on the surface of the cobalt chromium alloy

Curylofo, Patricia Almeida 24 January 2017 (has links)
A longevidade da prótese e a saúde bucal de usuário de Prótese Parcial Removível (PPR) são muito dependentes de higiene apropriada. O objetivo deste estudo foi comparar o efeito de soluções de Ricinus communis, em diferentes concentrações, com soluções de peróxido alcalino e cloreto de cetilpiridínio, em relação à liga metálica de Cobalto Cromo (Co-Cr) que compõe a estrutura de PPR. A amostra do experimento foi composta por 55 espécimes de Co-Cr, confeccionados a partir de padrões de cera circulares (12 mm x 3 mm) obtidos a partir de uma matriz metálica. Os padrões foram fundidos, numerados aleatoriamente e divididos em 5 grupos de imersão: H2O- água deionizada (controle) (15 minutos); Rc 2%- Ricinus communis 2% (20 minutos), Rc 10% -Ricinus communis 10% (20 minutos), PA- peróxido alcalino (15 minutos) e CCP- cloreto de cetilpiridínio 0,500 mg (10 minutos). Os espécimes foram avaliados quanto à rugosidade de superfície (n=10) no início e após a simulação de 6 meses, 1, 2, 3, 4 e 5 anos tanto pelo microscópio confocal a laser (Sa, &micro;m), como também pelo rugosímetro de superfície (Ra, &micro;m). Um espécime de cada grupo foi analisado quanto à topografia de superfície (Microscopia Eletrônica de Varredura, MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS) antes e após simulação de uso por 5 anos. De acordo com os resultados obtidos (&alpha;=0,05) pela microscopia confocal (Sa), não houve diferença para o fator solução (Kruskal-Wallis); para o fator tempo (Friedman) houve diferença estatística em Rc 2% entre T0 e T1, T3, T4 e T6 (p<0,001) e em Rc 10% de T2 para T3 (p=0,007), com diminuição da rugosidade. Com o rugosímetro (Ra), houve diferença estatística (Kruskal- Wallis) para CCP que apresentou menor rugosidade em relação à Rc 10% em T1 (p=0,048) e T6 (p=0,013). Em relação ao tempo (Friedman), a água propiciou diminuição da rugosidade superficial (Ra) de T0 para T2 (p=0,013). Na análise de MEV e EDS podese verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que embora tenha sido encontrada diferença estatística para a rugosidade, os resultados são clínicamentes aceitáveis. Deste modo, todas as soluções podem ser utilizadas com segurança pelo período de 5 anos. / Denture longevity and oral health of Removable Partial Denture (RPD) user are highly dependent on proper hygiene. The aim of this study was to compare the effect of solutions of Ricinus communis, in different concentrations, with solutions of alkaline peroxide and cetylpyridinium chloride 0.500 mg, in relation to the Cobalt Chromium (Co-Cr) alloy that composes the structure of RPD. The sample of the experiment consisted of 55 specimens of Co-Cr, made from circular wax patterns (12 mm x 3 mm) obtained in a metal matrix. The patterns were cast, randomly enumerated and divided into 5 immersion groups: H2Odeionized water (control) (15 minutes); Rc 2%- Ricinus communis 2% (20 minutes), Rc 10% -Ricinus communis 10% (20 minutes), PA-alkaline peroxide (15 minutes) and CCPcetylpyridinium chloride 0.500 mg (10 minutes). The specimens were evaluated for surface roughness (n = 10) at the beginning and after the simulation of 6 months, 1, 2, 3, 4 and 5 years by the laser confocal microscope (Sa, &micro;m) and by the rugosimeter of surface (Ra, &micro;m). One specimen from each group was analyzed for surface topography (Scanning Electron Microscopy, SEM) and Energy-dispersive X-ray spectroscopy (EDS) befofe and after simulation of use for 5 years. According to the results obtained (&alpha;= 0.05) by confocal microscopy (Sa), there was no difference for the solution factor (Kruskal- Wallis); For the time factor (Friedman) there was a statistical difference in Rc 2% in T0 to T1, T3, T4 and T6 (p <0.001) and Rc 10% in T2 to T3 (p = 0.007), with decrease in roughness. With the the rugosimeter (Ra), there was a statistical difference (Kruskal- Wallis) for CCP that presented less roughness in relation to the Rc 10% in T1 (p = 0.048) and T6 (p = 0.013). In relation to the time, (Friedman) the water caused a reduction of surface roughness (Ra) between T0 and T2 (p = 0.013). In the analysis of SEM and EDS it can be verified that the solutions did not present deleterious effects on the surfaces. It was concluded that although a statistical difference was found for roughness, the results are clinically acceptable. Thus, all solutions can be safely used for a period of 5 years.
4

Efeito de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio na superfície da liga metálica de cobalto cromo / Effect of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride on the surface of the cobalt chromium alloy

Patricia Almeida Curylofo 24 January 2017 (has links)
A longevidade da prótese e a saúde bucal de usuário de Prótese Parcial Removível (PPR) são muito dependentes de higiene apropriada. O objetivo deste estudo foi comparar o efeito de soluções de Ricinus communis, em diferentes concentrações, com soluções de peróxido alcalino e cloreto de cetilpiridínio, em relação à liga metálica de Cobalto Cromo (Co-Cr) que compõe a estrutura de PPR. A amostra do experimento foi composta por 55 espécimes de Co-Cr, confeccionados a partir de padrões de cera circulares (12 mm x 3 mm) obtidos a partir de uma matriz metálica. Os padrões foram fundidos, numerados aleatoriamente e divididos em 5 grupos de imersão: H2O- água deionizada (controle) (15 minutos); Rc 2%- Ricinus communis 2% (20 minutos), Rc 10% -Ricinus communis 10% (20 minutos), PA- peróxido alcalino (15 minutos) e CCP- cloreto de cetilpiridínio 0,500 mg (10 minutos). Os espécimes foram avaliados quanto à rugosidade de superfície (n=10) no início e após a simulação de 6 meses, 1, 2, 3, 4 e 5 anos tanto pelo microscópio confocal a laser (Sa, &micro;m), como também pelo rugosímetro de superfície (Ra, &micro;m). Um espécime de cada grupo foi analisado quanto à topografia de superfície (Microscopia Eletrônica de Varredura, MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS) antes e após simulação de uso por 5 anos. De acordo com os resultados obtidos (&alpha;=0,05) pela microscopia confocal (Sa), não houve diferença para o fator solução (Kruskal-Wallis); para o fator tempo (Friedman) houve diferença estatística em Rc 2% entre T0 e T1, T3, T4 e T6 (p<0,001) e em Rc 10% de T2 para T3 (p=0,007), com diminuição da rugosidade. Com o rugosímetro (Ra), houve diferença estatística (Kruskal- Wallis) para CCP que apresentou menor rugosidade em relação à Rc 10% em T1 (p=0,048) e T6 (p=0,013). Em relação ao tempo (Friedman), a água propiciou diminuição da rugosidade superficial (Ra) de T0 para T2 (p=0,013). Na análise de MEV e EDS podese verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que embora tenha sido encontrada diferença estatística para a rugosidade, os resultados são clínicamentes aceitáveis. Deste modo, todas as soluções podem ser utilizadas com segurança pelo período de 5 anos. / Denture longevity and oral health of Removable Partial Denture (RPD) user are highly dependent on proper hygiene. The aim of this study was to compare the effect of solutions of Ricinus communis, in different concentrations, with solutions of alkaline peroxide and cetylpyridinium chloride 0.500 mg, in relation to the Cobalt Chromium (Co-Cr) alloy that composes the structure of RPD. The sample of the experiment consisted of 55 specimens of Co-Cr, made from circular wax patterns (12 mm x 3 mm) obtained in a metal matrix. The patterns were cast, randomly enumerated and divided into 5 immersion groups: H2Odeionized water (control) (15 minutes); Rc 2%- Ricinus communis 2% (20 minutes), Rc 10% -Ricinus communis 10% (20 minutes), PA-alkaline peroxide (15 minutes) and CCPcetylpyridinium chloride 0.500 mg (10 minutes). The specimens were evaluated for surface roughness (n = 10) at the beginning and after the simulation of 6 months, 1, 2, 3, 4 and 5 years by the laser confocal microscope (Sa, &micro;m) and by the rugosimeter of surface (Ra, &micro;m). One specimen from each group was analyzed for surface topography (Scanning Electron Microscopy, SEM) and Energy-dispersive X-ray spectroscopy (EDS) befofe and after simulation of use for 5 years. According to the results obtained (&alpha;= 0.05) by confocal microscopy (Sa), there was no difference for the solution factor (Kruskal- Wallis); For the time factor (Friedman) there was a statistical difference in Rc 2% in T0 to T1, T3, T4 and T6 (p <0.001) and Rc 10% in T2 to T3 (p = 0.007), with decrease in roughness. With the the rugosimeter (Ra), there was a statistical difference (Kruskal- Wallis) for CCP that presented less roughness in relation to the Rc 10% in T1 (p = 0.048) and T6 (p = 0.013). In relation to the time, (Friedman) the water caused a reduction of surface roughness (Ra) between T0 and T2 (p = 0.013). In the analysis of SEM and EDS it can be verified that the solutions did not present deleterious effects on the surfaces. It was concluded that although a statistical difference was found for roughness, the results are clinically acceptable. Thus, all solutions can be safely used for a period of 5 years.

Page generated in 0.0697 seconds