11 |
Dissolucão eletrolítica de ligas de alumínio em cavacos e determinação dos elementos constituintes por espectrometria de emissão atômica com fonte de plasma (ICP-OES)GRIGOLETTO, TANIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:24Z (GMT). No. of bitstreams: 1
12433.pdf: 20959730 bytes, checksum: a98e9829a642f5e597da179c95c176ef (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
|
12 |
Avaliação da radioatividade natural em águas potáveis de superfície e subterrâneas da Região de Caetité, BA / Evaluation of natural radioactivity in superficial and underground drinking water, from the Caetité region, BASILVA, LUCIANA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:40Z (GMT). No. of bitstreams: 0 / O Brasil possui a sétima maior reserva geológica de urânio do mundo, com aproximadamente 310 mil toneladas. A Província Uranífera de Lagoa Real, na região de Caetité e Lagoa Real, situado no centro sul da Bahia, é considerada a mais importante província monominerálica do Brasil. A população urbana que vive no distrito uranífero nas cidades de Caetité, Lagoa Real e Livramento de Nossa Senhora usa água potável oriunda do abastecimento público. Na área rural, caracterizada por freqüentes secas, os moradores recebem água de poços escavados e perfurados como também, de pequenas barragens e reservatórios abastecidos pelas chuvas. Este trabalho determinou os níveis de radioatividade alfa e beta total e as concentrações de urânio em diversos tipos de água consumidas pela população urbana e rural da Província Uranífera de Lagoa Real. As atividades α e β total foram determinadas com detector proporcional de fluxo gasoso e baixa radiação de fundo. As concentrações de urânio foram determinadas com o Espectrômetro de Massa com Fonte de Plasma Indutivo (ICP-MS). Os resultados obtidos foram comparados com as recomendações recentes de 2011 da Organização Mundial da Saúde, a portaria nº 2914 de 12/12/2011 do Ministério da Saúde e as resoluções do CONAMA. Os níveis de radiação natural variaram de 0,0041 ± 0,0004 Bq.L-1 a 0,80 ± 0,04 Bq.L-1 para a atividade alfa total e de 0,045 ± 0,003 a 3,0 ± 0,2 Bq.L-1 para a atividade beta total. Tendo como parâmetro a OMS e o MS, apenas duas amostras de água subterrânea, uma localizada na cidade de Lagoa Real e outra na cidade de Caetité apresentaram concentrações alfa total acima do valor de 0,5 Bq.L-1 descrito em suas recomendações, 0,80 ± 0,04 Bq.L-1 e 0,57 ± 0,03 Bq.L-1respectivamente. Para beta total, três amostras apresentaram níveis de radioatividade acima do limite de 1 Bq.L-1 recomendado pela Organização Mundial de Saúde e estabelecido pelo Ministério da Saúde; 3,0 ± 0,2 Bq.L-1; 1,63 ± 0,13 Bq.L-1 e 1,19 ± 0,07 Bq.L-1 todos situados no município de Lagoa Real. Duas amostras de água subterrânea no município de Caetité apresentaram concentrações de urânio acima do valor de 15 μg.L-1 determinado pelo CONAMA, 20,3 ± 0,3 μg.L-1 e 17,1± 0,3 μg.L-1. Em Lagoa Real, uma amostra apresentou níveis de urânio seis vezes superior ao limite estabelecido pelo Conselho Nacional de Meio Ambiente, 89,5 ± 1,5 μg.L-1. A Organização Mundial da Saúde em 2004 estabeleceu em suas recomendações o limite de 15 μg.L-1 como a concentração máxima de urânio na água potável. Em 2011 a OMS aumentou este limite para 30 μg.L-1. Levando-se em consideração as atuais recomendações da OMS, apenas a concentração de uma amostra de água apresentou níveis de urânio acima do recomendado, 89,5 ± 1,5 μg.L-1 no município de Lagoa Real. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
13 |
Development and application of a calibration technique for laser ablation-ICP-MSBoue-Bigne, Fabienne January 2000 (has links)
Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS) is a powerful analytical technique for the direct elemental analysis of solid samples, with spatial resolution down to a few microns However, calibration remains the limiting factor in obtaining quantitative analysis by LA-ICP-MS for a wide range of sample types. No universal method exists as yet and the ones that are currently used tend to employ matrix-matched solid standards Matrix-matched solid standards are not available for many types of sample, such as polymers, biological materials, fluid inclusions, etc The need for a universal method of calibration that involves standards that are easy to prepare and suitable for any type of sample is required. Additional to matrix-matching, internal standards are widely used in LA-ICP-MS for quantitative analyses The internal standard compensates for the different ablation yields from the sample and the standard and for the laser shot to shot variation. Given that the use of an internal standard is required to obtain reliable results, the need for matrix-matching might be regarded as questionable This project has focused on the development and application of a new method of calibration for LA-ICP-MS. It involves the use of aqueous standards whose absorption characteristics are modified by the addition of a chromophore to the solution. Additives were selected for ablation with KrF excimer, and Nd.YAG lasers The influence of the additive concentration on the ablation yield was investigated for different laser energies. Response curves were obtained showing that as the additive concentration was increased, less energy was required to ablate the modified standard solutions efficiently. A general procedure was then defined for the preparation and use of the modified standard solutions for a given sample. The new method of calibration was used for the quantitative analysis of different sample types· low density polyethylene (LDPE), polyketone (PK), polyethylene thin film as well as gels contained in the thin film, and stainless steel. Investigations were carried out on the mechanism of ablation of the modified standard solutions. It appeared that the ablation proceeded by a three-step process leading ultimately to nebulisation of the bulk liquid.
|
14 |
Analise multielementar e isotopica em compostos de uranio por espectrometria de massa com fonte de plasma induzido ( ICPMS )OLIVEIRA JUNIOR, OLIVIO P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:23Z (GMT). No. of bitstreams: 1
06890.pdf: 3271433 bytes, checksum: 57399ce5f630231a9b2741455ed096f0 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
15 |
Uso da monitoracao ambiental como tecnica de identificacao de atividades de enriquecimento isotopicoBUCHMANN, JOSE H. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:34Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:11Z (GMT). No. of bitstreams: 1
06861.pdf: 8656275 bytes, checksum: 33d75be9bc7f27a315785b762567f56c (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
16 |
Avaliação da poluição atmosférica por metais na região metropolitana de São Paulo utilizando a bromélia Tillandsia usneoides L. como biomonitorNOGUEIRA, CLAUDIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:50Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
17 |
Rastreamento da origem geográfica de amostras de maconha apreendidas nas ruas de São Paulo, por meio de assinaturas químicasSHIBUYA, ELISA K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:13Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:44Z (GMT). No. of bitstreams: 1
10554.pdf: 11520405 bytes, checksum: 77369e7569e528de44a78a67c7e707b6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:00/09814-0
|
18 |
Identificação de assinaturas químicas em resíduos de disparos de arma de fogo em diferentes alvos / Identification of chemical sgnatures of gunshot residues in differents fabricsFREITAS, JOAO C.D. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:59Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
19 |
Metais presentes nas águas e em tecidos de peixes da represa Billings: uma avaliação temporal / Presents metals in water and fish tissue of Billings Dam: a temporal evaluationOLIVEIRA, TALITA A. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:59Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:10/04953-4
|
20 |
Desenvolvimento e validacao de uma metodologia de analise multielementar em amostras de soro sanguineo por espectrometria de massas de alta resolucao com fonte de plasma indutivoMONTEIRO, LUCILENA R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:36Z (GMT). No. of bitstreams: 1
07113.pdf: 9391955 bytes, checksum: 43c2cba15e3c3febc7584c08bb3efb4e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.3871 seconds