• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 8
  • 8
  • 8
  • 8
  • 8
  • 2
  • Tagged with
  • 51
  • 51
  • 35
  • 25
  • 12
  • 11
  • 11
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Propriedades fotoeletroquimicas do polipirrol-dodecilsulfato

Martini, Milena 24 July 2018 (has links)
Orientador: Marco-Aurelio De Paoli / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-24T21:56:21Z (GMT). No. of bitstreams: 1 Martini_Milena_D.pdf: 3698214 bytes, checksum: 3edd12df9aa618e80d46e9764661cddf (MD5) Previous issue date: 1998 / Doutorado
2

Influência de anisotropia induzida e magnetostrição na magnetoimpedância e em sua relaxação em fitas amorfas de FeCoSiB

Pirota, Kleber Roberto, 1973- 27 March 1998 (has links)
Orientador: Marcelo Knobel / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-24T05:59:18Z (GMT). No. of bitstreams: 1 Pirota_KleberRoberto_M.pdf: 6929986 bytes, checksum: e924283959aa4f3b0c8be364e71db523 (MD5) Previous issue date: 1998 / Resumo: Magnetoimpedância Gigante ( GM/) é o termo utilizado para descrever variações grandes e sensíveis na impedância, medida a alta frequência, de um material magnético doce, causadas pela aplicação de um campo magnético externo. Desde de sua descoberta recente, a GMI tem atraído muita atenção devido .as enormes perspectivas de aplicações tecnológicas, principalmente em sensores magnéticos. O mecanismo básico responsável pelo fenômeno da GMI está relacionado a mudanças na profundidade de penetração causadas pelas mudanças ocorridas na permeabilidade transversal da amostra devido a aplicação do campo externo. Outro efeito bastante interessante, que foi recentemente descoberto em amostras amorfas, é a lenta relaxação da sua impedância após uma mudança súbita na configuração de domínios. Este efeito, conhecido como aftereffect da GMI (MIAE), possui implicações técnicas importantes pois, após o rearranjo de estrutura de domínios da amostra, sua impedância leva alguns segundos para atingir um valor de equilíbrio, seguindo uma cinética quase-logarítirnica. Propõe-se que este efeito está conectado com o da relaxação da permeabilidade inicial ( desacomodação ). Este trabalho apresenta resultados do efeito da GMI e de sua relaxação em fitas amorfas de composição (FexCO1-x)7OSi12B18 com valores de x próximos de 0.057, antes e depois de um tratamento térmico tendo as seguintes condições: 1 h de pré-tratamento a uma temperatura de 360°C seguido de 1 h de tratamento a uma temperatura de 340oC, porém com uma tensão de 400 MPa aplicada longitudinalmente à amostra.. Foi estudada a influência da constante de magnetostrição de saturação ls e da anisotropia induzida pelo referido tratamento, nos efeitos da GMI e do MIAE. Foi verificado que a forma da curva GMI vs. campo externo é extremamente sensível a anisotropia induzida pelo tratamento térmico, e que o MIAE foi drasticamente reduzido após o tratamento. Os resultados do MIAE obtidos para uma frequência de 100 kHz da corrente de sonda foram explicados utilizando os modelos de desacomodação já existentes, enquanto que a causa do efeito para 900 kHz foi atribuída a mecanismos de dissipação / Abstract: Giant Magnetoimpedance (GMI) is a term coined to describe large and sensitive field induced changes in the high frequency impedance of soft magnetic materials. Since its recent discovery, GMI has attracted much attenction owing to the enormous perspectives in technological aplications, mainly as magnetic field sensors. The basic mechanism responsible for the GMI phenomenon is the change of the magnetic penetration depth through field induced modifications of the transversal permeability. Another interesting effect that has been recently discovered in amorphous samples is the slow relaxation of the impedance after a sudden change of the domain configuration. This effect, known as Magnetoimpedance Aftereffect (MJAE), has important technical implications because the impedance takes few seconds to achieve a stable value, following a quasi-logarithmic kinetics. This effect seems to be connected with the relaxation of the initial magnetic permeability (disaccommodation). This work presents results of GMJ effect and its relaxation in amorphous ribbons of composition (FexCo1-x)7OSi12B18 whith x values close to 0.057, before and after a thermal annealing consisting of 1 h pre-annealing at 360°C followed by 1 h stress-annealing at 340°C whith applied tensile stress of 400 MPa. The influence of saturation magnetostricton constant ls and anisotropy induced by this particular annealing was studied on GMJ and MJAE effects. It was verified that the shape of the impedance vs. applied field curves results to be extremely sensitive to the induced anisotropies, and that the MIAE effect was drastically suppressed after annealing. The results of MlAE obtained from 100 kHz frequency of driving current are aplained using the existent disaccommodation models, while in the case of 900 kHz dissipatives mechanisms were considered. / Mestrado / Física / Mestre em Física
3

Impedância bioelétrica na ocorrência da pré-eclâmpsia /

Silva, Elaine Gomes da. January 2012 (has links)
Orientador: José Carlos Peraçoli / Coorientador: Maria Antonieta de Barros Leite Carvalhaes / Banca: Roberto Antonio de Araújo Costa / Banca: Roseli Yamamoto Nomura / Banca: Mary Ângela Parpinelli / Banca: Maria Helena B. Benício / Resumo: Analisar possíveis associações entre resistência e reactância, avaliadas pela análise de impedância bioelétrica (BIA), no primeiro, segundo e terceiro trimestres de gestação, e ocorrência de pré-eclâmpsia; identificar qual o momento mais precoce da associação. Coorte prospectiva. Hospital das Clinicas da Faculdade de Medicina de Botucatu/Unesp. 380 gestantes acompanhadas no Serviço. As gestantes foram submetidas à BIA, no primeiro (até 14 semanas), segundo (15 a 28 semanas) e terceiro (29 a41 semanas) trimestres, para avaliação dos valores de resistência e reactância. Considerou-se o desenvolvimento de hipertensão arterial, após a 20ª semana, com ou sem proteinúria, respectivamente, Pré-eclâmpsia (PE) e Hipertensão Gestacional (HG). Foi realizada a análise estatística através teste T de student e do Odds-Ratio considerando p<0,05. No primeiro trimestre a média da resistência e reactância do grupo PE (508Ω;57Ω) foi significativamente menor que a observada no grupo normotenso (580Ω;66Ω). No segundo trimestre as médias de resistência e reactância no grupo PE, respectivamente, (502Ω e 53Ω), foram menores significativamente do que as encontradas no grupo normotenso (566Ω e 57Ω). No terceiro trimestre foram também significativamente menores quando comparadas com o grupo normotenso (452 Ω e 47 Ω). No primeiro trimestre o Odds ratio (OR) para a resistência foi de 0,99 (IC 0,98 - 1,0) com p=0,002 e reactância foi de 0,93 (IC 0,85- 1,01) com p=0,07. No Segundo trimestre o OR foi de 0,99 (IC 0,98-0,99) e p=0,001 e a reactância o OR foi de 0,95 (IC=0,9-1,00) com p=0,05. No terceiro trimestre o OR foi de foi de 0,99 (IC 0,98-0,99) e p=0,0010 para resistência e de 0,93 (IC 0,88 - 0,98) e p=0,01 para reactância. A bioimpedância mostrou associação através da resistência tanto no primeiro quanto no segundo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To analyze possible associations between resistance and reactance, as evaluated by electrical impedance analysis (BIA) in the first, second and third pregnancy trimesters, and preeclampsia occurrence; to identify the earliest moment of association. Prospective cohort. Botucatu School of Medicine University Hospital/Unesp. Population: 380 pregnant women attended to by the Service. The pregnant women underwent BIA in the first (up to 14 weeks), second (15 to 28 weeks) and third (29 to 41 weeks) trimesters for evaluation of resistance and reactance values. The development of arterial hypertension, after the 20th week, with or without proteinuria, respectively, Preeclampsia (PE) and Gestational Hypertension (GH) was considered. Statistical analysis by Odds-Ratio was performed considering p<0.05. In the first trimester, the resistance and reactance means in the PE group (508Ω;57Ω) were significantly lower than those observed in the healthy group (580Ω;66Ω). In the second trimester, the resistance and reactance means in the PE group, respectively (502Ω and 53Ω), were lower than those found in the healthy group (566Ω and 57Ω). In the third trimester were lower than than those found in the healthy group (452 Ω e 47 Ω). In the first trimester, the Odds ratio (OR) for resistance was 0.99 (CI 0.98 - 1.0) with p=0.002, and reactance was 0.93 (CI 0.85-1.01) with p=0.07. In the second trimester, OR was 0.99 (CI 0.98-0.99) and p=0.001, and for reactance, OR was 0.95 (CI=0.9-1.00) with p=0.05. In the third trimester, the Odds ratio (OR) for resistance was (IC 0,98-0,99) with p=0,0010 and 0,93 (IC 0,88 - 0,98) with p=0,01 for reactance. Bioimpedance showed association by means of resistance both in the first... (Complete abstract click electronic access below) / Doutor
4

Sensor químico baseado em microponte de impedância = Chemical sensor based on impedance microbridge / Chemical sensor based on impedance microbridge

Ribeiro, Luiz Eduardo Bento 21 August 2018 (has links)
Orientador: Fabiano Fruett / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T04:02:00Z (GMT). No. of bitstreams: 1 Ribeiro_LuizEduardoBento_M.pdf: 4022818 bytes, checksum: d2a40b9cee4f59bc80ec0b09a97c31a8 (MD5) Previous issue date: 2012 / Resumo: A integração de sistemas microeletrônicos em lab-on-a-chip está sendo cada vez mais necessária para concretizar novas aplicações dentro do emergente campo da microfluídica. Tanto na química quanto na bioquímica e até mesmo na medicina e bioengenharia, a microfluídica evolui conquistando um espaço crescente. Entretanto, desafios tecnológicos residem na sua complexa fabricação e integração com sistemas eletrônicos. Neste trabalho, foi desenvolvido um sistema sensor que emprega métodos de fabricação compatíveis tanto com a microeletrônica quanto com a microfluídica. Este sistema sensor é baseado em uma microponte de impedância composta por quatro capacitores interdigitados. Neste sistema, o fluido, guiado por um canal ou armazenado em um reservatório fabricado em polidimetilsiloxano (PDMS), passa sobre a microponte enquanto um termistor, fabricado no mesmo substrato, permite monitorar a temperatura do sistema durante a medida. A microponte é formada de eletrodos interdigitados arranjados de forma a permitir a utilização de um circuito eletrônico de condicionamento que pode ser construído bem próximo do elemento sensor. O trabalho foi validado comparando-se a função de transferência experimental do sensor, usando como analito a mistura etanol-água, com a função de transferência teórica obtida através de simulação baseada em elementos finitos. Identificamos a importância da deposição de um filme fino de boa qualidade para a proteção dos eletrodos de referência e sua influência na função de transferência experimental. Ainda, devido à utilização de materiais inertes como ouro, vidro e PDMS, o sistema sensor, com alguns ajustes, pode ser empregado para outras aplicações: desde o monitoramento da pureza e concentração de líquidos até a caracterização de filmes finos sensíveis a patógenos e fármacos / Abstract: The integration of microelectronic systems in lab-on-a-chip is being increasingly required to implement new applications on the emerging field of microfluidics. Both in chemistry and biochemistry, and even in medicine and bioengineering, microfluidics evolves gaining a growing space. However, technological challenges lie in its complex manufacturing and integration with electronic systems. In this work, we developed a sensor system that employs both fabrication methods compatible with microelectronics and with microfluidics. This sensor system is based on an impedance microbridge composed of four interdigitated capacitors. In this system, the fluid which is guided by a channel or is stored in a reservoir made of polydimethylsiloxane (PDMS), passes over the microbridge while a thermistor fabricated on the same substrate allows monitoring of the system temperature during the measurement. The microbridge is made of interdigitated electrodes arranged so as to allow the use of an electronic conditioning circuit that can be built very close to the sensor element. The study was validated by comparing experimental transfer function of the sensor, using the ethanol-water mixture as analyte, with the theoretical transfer function obtained by simulation based on finite element method. We identified the importance of depositing a good quality thin film for the protection of reference electrodes and its influence on experimental transfer function. Also, due to the use of inert materials such as gold, glass and PDMS, the sensor system, with some adjustments, can be used for other applications: from monitoring of the concentration and purity of liquid to the characterization of thin films sensitive to drugs and pathogenic agents / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
5

Magnetoimpedância gigante em fios e fitas amorfos

Pirota, Kleber Roberto, 1973- 25 January 2002 (has links)
Orientador: Marcelo Knobel / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-31T23:50:19Z (GMT). No. of bitstreams: 1 Pirota_KleberRoberto_D.pdf: 7210196 bytes, checksum: c9218cbcb20790395e19215f5ecf5a7f (MD5) Previous issue date: 2002 / Resumo: Esta tese mostra os resultados de três anos e meio dedicados a investigação do fenômeno da Magnetoimpedância gigante (GMI) em fitas ferromangéticas amorfas e microfios amorfos cobertos por uma camada de vidro. Os resultados obtidos em microfios comprovaram a viabilidade da sua utilização em aplicações que usam o fenômeno da Magnetoimpedância. Com relação às fitas, com a indução de anisotropia transversal mediante tratamentos térmicos com tensão, deixou-se claro a possibilidade de se construir um sensor de tensão que faz uso da GMI. Além do trabalho experimental, que envolveu caracterização magnética de amostras, tratamentos térmicos e medidas de GMI, também foi dada uma contribuição teórica no que diz respeito ao entendimento da influência de anisotropias magnéticas e sua distribuição no efeito da GMI / Abstract: This work shows the results of the Giant Magnetoimpedance (GMI) investigations in ferromagnetics ribbons and glass-covered amorphous microwires. The results in microwires demonstrate the viability of its use for GMI applications. Concerning the ribbons, with induced transversal magnetic anisotropy by means of stress-annealing, the possibility of its use as a stress sensor was comproved. In addition witn the experimental work, also some theoretical contribution was done in order to clarify the influence of anisotropies and its distribution on GMI effect / Doutorado / Física / Doutor em Ciências
6

Sistema de medição de impedancias complexas utilizando dispositivo de seis portas

Giraudo, Elvio Cesar 17 August 1990 (has links)
Orientador: Rui Fragassi Souza / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-13T21:49:52Z (GMT). No. of bitstreams: 1 Giraudo_ElvioCesar_M.pdf: 5651722 bytes, checksum: 3d5fc99145d2120773cc5f95c057579b (MD5) Previous issue date: 1990 / Resumo: Este trabalho tem como finalidade mostrar a viabilidade de medir impedâncias complexas via dispositivo de seis portas. Neste sentido, realizou-se uma abordagem teórica seguida da implementação de um sistema ("Hardware" e ¿Software") controlado por um microcomputador de 16 bits. O dispositivo de seis portas é constituído por uma linha de transmissão do tipo microfita, amostrada por quatro sensores. São apresentadas rotinas de calibração para o dispositivo de seis portas, assim como de medições e apresentação de dados. Foram realizadas algumas medições na banda baixa de microondas e foi feito um confronto com um aparelho comercial com mesma finalidade, obtendo-se bons resultados. A portabilidade do sistema e o baixo custo do mesmo é um bom motivo para seu uso com fins didáticos e acadêmicos / Abstract: This work presents the design and implementation of a system that allows the measurement of complex impedances using a six-port network at microwave frequencies. The six-port device used was a "sampled line" microstrip. The basic theory is presented initially, followed by an outline of the hardware and software developed to interconnect the six-port with a PC microcomputer. A calibration routine is presented that avoids any iterative process and, therefore, is rapidly executed. Several measurements are presented in the low microwave range (up to 4 GHz) and are compared with the corresponding values obtained using a commercial network analyser. Good agreement is obtained in most cases. Suggestion to upgrade the system is presented.Low cost and easy portability are good reasons that recommends the use of this system for teaching purposes / Mestrado
7

Desenvolvimento de um modelo eletromecânico para diafragmas piezelétricos utilizados em sistemas de monitoramento de integridade estrutural /

Freitas, Everaldo Silva de. January 2018 (has links)
Orientador: Fabrício Guimarães Baptista / Banca: Marcelo Nicoletti Franchin / Banca: Paulo Sergio da Silva / Banca: José Guilherme Magalini Santos Decanini / Banca: Mário Anderson de Oliveira / Resumo: Os diafragmas piezelétricos são componentes eletrônicos de baixo custo utilizados em diversas aplicações. Seu uso mais comum é como transdutor de áudio e, nesse tipo de aplicação, é mais comumente conhecido como buzzer. Nos últimos anos, a utilização desses componentes em estudos científicos avançados tem aumentado bastante, e uma das áreas que tem merecido destaque é a dos sistemas de Monitoramento de Integridade Estrutural - Structural Health Monitoring (SHM) - baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial por se basear no uso de transdutores piezelétricos pequenos e leves minimamente invasivos à estrutura monitorada. Portanto, tomando como base o crescente interesse por esses componentes, é proposto neste estudo um circuito eletromecânico equivalente básico que relacione as propriedades elétricas dos diafragmas piezelétricos com as propriedades mecânicas da estrutura monitorada por meio da impedância elétrica. Essa relação é baseada no efeito piezelétrico, que proporciona um acoplamento eletromecânico com a estrutura monitorada e, portanto, permite avaliar as condições mecânicas da estrutura a partir das propriedades elétricas do transdutor. A estrutura utilizada no estudo foi uma barra de alumínio com dimensões de 500 mm x 38,10 mm x 3,18 mm, tipicamente utilizada em laboratórios, e diafragmas com espessuras da ordem de uma fração de milímetro. Nessas condições, o modo de vibração principal pode ser ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Piezoelectric diaphragms are inexpensive electronic components used in a variety of applications. Its most common use is as an audio transducer and, in this type of application, it is commonly known as "buzzer". In recent years, the use of these components in advanced scientific studies has increased significantly, and one of the areas that has received special mention is the Structural Health Monitoring (SHM) systems based on electromechanical impedance (EMI). This type of application has received special attention because it is based on the use of small and lightweight piezoelectric transducers minimally invasive to the monitored structure. Therefore, based on the growing interest in these components, a basic equivalent electromechanical circuit is proposed in this study that relates the electrical properties of the piezoelectric diaphragms to the mechanical properties of the monitored structure through the electrical impedance. This relationship is based on the piezoelectric effect, which provides an electromechanical coupling with the monitored structure and, therefore, allows to evaluate the mechanical conditions of the structure from the electrical properties of the transducer. The structure used in the study was an aluminum bar with dimensions of 500 mm x 38.10 mm x 3.18 mm, typically used in laboratories, and diaphragms with thicknesses of the order of a fraction of millimeter. Under these conditions, the main vibration mode can be considered in the longitudinal ... (Complete abstract click electronic access below) / Doutor
8

Estudo das propriedades dielétricas e de bloqueio das monocamadas automontadas /

Benites, Tiago Azevedo. January 2013 (has links)
Orientador: Paulo Roberto Bueno / Coorientador: Márcio de Sousa Góes / Banca: Antonio Pupim / Banca: Ernesto Chavez / Resumo: O estudo das propriedades dielétricas das monocamadas automontadas de alcanotióis sobre o ouro (SAMs) é importante no campo da biotecnologia, já que essas camadas proporcionam uma estrutura fundamental na construção dos eletrodos quimicamente modificados, com sua principal aplicação na confecção dos biossensores. A análise das propriedades de bloqueio pelas SAMs é frequentemente feita por meio de técnicas eletroquímicas e de resposta em frequência, pois são extremamente eficazes no entendimento das características físico-químicas interfaciais de modificação desses filmes, além de apresentarem praticidade e velocidade de realização. Uma forma bastante apropriada de analisar a capacidade dielétrica das SAMs é quantificando a velocidade de transferência eletrônica frente a uma espécie eletroativa. Nesse trabalho foram caracterizadas monocamadas de diferentes espessuras em um meio com espécie eletroativa em concentrações variadas, a partir do cálculo da constante de transferência heterogênea de elétrons, feitas pelas metodologias propostas por diferentes autores e por uma metodologia inédita que será detalhada no corpo do trabalho / Abstract: The study of the dielectric properties of self-assembled monolayers of alkanethiols on gold (SAMs) is of paramount importance to biotechnology, as these layers provide a fundamental structure in the construction of chemically modified electrodes, with its main application in fabrication of biosensors. The analysis of the blocking properties of SAMs is often done by electroanalytical techniques and frequency response, as they are extremely effective in understanding the physico-chemical interfacial modification of these films, and offer convenience and speed of execution. A very appropriate manner of evaluating the blocking ability of SAMs is quantifying dielectric constant and the heterogeneous electron transfer rate across from one electroactive species in solution. In this study monolayers of different thicknesses were characterized in a medium with electroactive species in different concentrations to calculate of the heterogeneous electron transfer constant by classical methods which were compared with a new methodology detailed in the present work / Mestre
9

Avaliação experimental de um sistema não linear para extração de energia através de vibrações utilizando material piezelétrico /

Carvalho, Felipe Carmo. January 2014 (has links)
Orientador: Vicente Lopes Junior / Co-orientador: Samuel da Silva / Banca: Joao Antonio Pereira / Banca: Milton Dias Junior / Resumo: Afim de suprir a necessidade por fontes alternativas de energia para a alimentação de sistemas microeletrônicos autônomos, os estudos têm se voltado para a utilização de materiais piezelétricos para a transformação de energia derivadas de vibrações mecânicas em energia elétrica. Como a potência fornecida pelas vigas com materiais piezelétricos é pequena e, geralmente, insuficientes para alimentar dispositivos eletrônico de forma autônoma, técnicas de extração, conversão e armazenamento de energia são utilizadas para otimizar a energia final acumulada. Neste sentido, este trabalho tem por objetivo a otimização de um sistema extrator de energia através de vibrações utilizando material piezelétrico, maximizando a potência extraída e melhorando o rendimento do sistema. Para isto, foram analisadas condições de linearidade e não linearidade no sistema e os respectivos circuitos conversores foram projetados e testados experimentalmente. A melhor configuração eletromecânica para extração de energia, o sistema será utilizada para alimentar um sistema autônomo. Foram projetados dois sistemas de monitoramentos com consumo de energia diferentes, para avaliar as limitações e potencialidades da proposta de sistema para extração de fontes alternativas de energia elétrica / Abstract: In order to meet the need for alternative energy sources to power autonomous microelectronic systems, studies have focused on the use of piezoelectric materials to transform energy derived from mechanical vibrations into electrical energy. Once the power delivered by the cantilever beams with piezoelectric materials are insufficient to power electronic devices autonomously, extraction techniques, conversion and energy storage was used to optimize the final accumulated energy. Considering that, this work aims at the optimization of an extractor system energy through vibrations using piezoelectric material, maximizing the power extracted and improving system performance. To this end, conditions of linearity and non-linearity in the mechanical system, as well as designed and tested converter circuits were analyzed. The best setup for electromechanical energy extraction, was used to feed an autonomous system. Two different power consumption-monitoring systems were designed to assess the limitation and potentialities of the proposed alternative for energy harvesting / Mestre
10

Estudo de sensores PZT aplicados à detecção de danos em tubulações /

Pita Ruiz, Julián Leonel. January 2014 (has links)
Orientador: Jozué Vieira Filho / Banca: Suely Cunha Amaro Mantovani / Banca: Bernardo José Guilherme de Aragão / Resumo: Neste trabalho propõe-se o monitoramento da integridade estrutural (SHM) em sistemas de tubulações usando-se a técnica da impedância Eletromecânica (EMI), que é uma forma de avaliação não destrutiva (NDE). A técnica EMI tem como base a Função de Resposta em Frequência (FRF) e se destaca por utilizar transdutores piezelétricos de baixo custo. Através da implementação de um sistema de SHM nas tubulações, é possível monitorar a integridade estrutural de forma contínua e reduzir, assim, os riscos de acidentes que podem prejudicar a população e o meio ambiente. A técnica proposta é baseada em transdutores do tipo PZT, que são colados na superfície curva do corpo principal do tubo da estrutura por meio de um adesivo de alta rigidez, e tem como vantagem básica a simplicidade. Os sensores, devidamente posicionados, são excitados em uma determinada faixa de frequência, gerando uma resposta que é medida através da impedância elétrica. O processo de monitoramento da integridade estrutural da tubulação é feito através de medições periódicas da impedância da estrutura e a detecção do dano é baseada nas alterações das respostas. Para detectar o dano, as diferentes medições são analisadas usandose índices de falha métrica tradicionais na área de SHM, como o RMSD RMSD (Root Mean Square Deviation) e o CCDM (Correlation Coefficient Deviation Metric). A técnica utilizada demonstrou capacidade para identificar corretamente a presença de danos no corpo principal dos segmentos de tubos das estruturas utilizadas, mostrando-se viável para detecção de danos em tubulações / Abstract: In this work proposes the Structural Health Monitoring (SHM) in piping systems using the technique of Electromechanical Impedance (EMI), which is a form of non destructive Evaluation (NDE). The EMI technique is based on the Frequency Response Function (FRF) known for its simplicity and for the use of low cost piezoelectric transducers. Through the implementation of a SHM system on the pipes, if possible to monitor the structural integrity continuously, reducing the risk of accidents to the people and the environment. The proposed technique is based on the PZT transducers type, which are pasted on the curved surface of the main body of the pipe with a high stiffness adhesive. The sensors, properly positioned, are excited in a certain range frequency, generating a response that is measured by the electrical impedance. The process of monitoring the structural integrity of the pipes is done through periodic measurements of the impedance and the detection of damage is based on the responses changes. To detect the damage, the different measurements are analyzed using the traditional metric damage indexes in the area of ? SHM, the RMSD (Root Mean Square Deviation) and the CCDM (Correlation Coefficient Deviation Metric). The technique has demonstrated its ability to correctly identify the presence of damage on the main body of the pipes segments of the structures / Mestre

Page generated in 0.0319 seconds