• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 111
  • 111
  • 38
  • 21
  • 20
  • 15
  • 14
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Ensino de grandezas e medidas: uma proposta com materiais didáticos manipuláveis para o 6º do ensino fundamental / Teaching of quantities and measures: a proposal with manipulative didactic materials for the 6th year of elementary school

Lima, Alana 02 August 2017 (has links)
Acompanha: Ensino de grandezas e medidas: uma proposta de sequência didática com materiais manipuláveis / O objetivo deste estudo é analisar como o uso de Materiais Manipuláveis pode contribuir para o processo de aprendizagem dos conceitos de Grandezas e Medidas para alunos do 6º ano do Ensino Fundamental. Partiu-se do pressuposto de que a aprendizagem constitui um processo de construção de significado dos objetos e, essa compreensão depende das experiências de vida de cada sujeito sendo entendido como conhecimentos prévios dos alunos. Nessa perspectiva, foi elaborada e aplicada uma sequência didática, a partir do tema Grandezas e Medidas. Do ponto de vista metodológico, o estudo inseriu-se numa pesquisa qualitativa, de natureza interpretativa, envolvendo alunos do 6º ano do Ensino Fundamental de um colégio público estadual da cidade de Ortigueira - PR. A pesquisa orientou-se pela seguinte questão: Quais as contribuições que o uso de Materiais Manipuláveis poderá trazer para a aprendizagem de Grandezas e Medidas no 6º Ano do Ensino Fundamental? Os dados utilizados neste trabalho foram coletados durante todo o desenvolvimento da sequência didática, com o uso dos seguintes instrumentos: aplicação da avaliação diagnóstica, observação, fotografias, registros escritos e relatos orais. Os resultados indicam que as atividades dos módulos da sequência didática, contribuíram para o avanço progressivo dos conhecimentos dos alunos, demonstrando que é possível, efetivar um trabalho diferenciado e contextualizado, centrado na formação para a cidadania. Vale lembrar que a implementação dessa proposta requer esforço coletivo e concretização do compromisso inerente à ação pedagógica - a prática da pesquisa, da reflexão e da formação permanente. Com o propósito de compartilhar saberes docentes com outros profissionais da área, como produto final desse trabalho, foi elaborado um caderno pedagógico, contendo uma sequência didática com um conjunto de atividades didáticas que viabilizem a utilização de Materiais Manipuláveis como ferramenta pedagógica nas séries finais do Ensino Fundamental, intitulado: “Ensino de Grandezas e Medidas: uma proposta de sequência didática com materiais manipuláveis”. / The objective of this study is to analyze how the use of Manipulable Materials can contribute to the process of learning the concepts of Greatness and Measures for students of the 6th year of Elementary School. It was assumed that learning is a process of constructing meaning of objects and that understanding depends on the life experiences of each subject being understood as prior knowledge of the students. From this perspective, a didactic sequence was elaborated and applied, based on the theme Grandezas e Media. From the methodological point of view, the study was inserted in a qualitative research, of an interpretative nature, involving students of the 6th grade of Elementary School of a state public college in the city of Ortigueira - PR. The research was guided by the following question: What contributions could the use of Manipulable Materials bring to the learning of Greatness and Measures in the 6th Year of Elementary Education? The data used in this work were collected throughout the development of the didactic sequence, using the following instruments: application of diagnostic evaluation, observation, photographs, written records and oral reports. The results indicate that the activities of the modules of the didactic sequence contributed to the progressive advancement of the students' knowledge, demonstrating that it is possible to carry out a differentiated and contextualized work centered on the formation of citizenship. It is worth remembering that the implementation of this proposal requires collective effort and concretization of the commitment inherent in pedagogical action - the practice of research, reflection and permanent formation. With the purpose of sharing teacher knowledge with other professionals of the area, as a final product of this work, a pedagogical book was elaborated, containing a didactic sequence with a set of didactic activities that enabled the use of Manipulable Materials as pedagogical tool in the final series of Teaching Fundamental, titled: "Teaching of Greatness and Measures: a proposal for a didactic sequence with manipulable materials".
92

Contribuição para classificação e descrição do caimento dos tecidos de seda 100% empregados em vestuário / Contribution for the classification and description of the 100% silk fabric hanging folds to be used in fashion clothing

Brehm, Leda Maria Stumpf January 2011 (has links)
O consumidor de têxteis confeccionados percebe a qualidade da roupa pela estética, caimento, toque e durabilidade. A cor e a textura, juntamente com o caimento do tecido, contribuem para a beleza do modelo. Na seleção do material para a confecção de vestuário, essas características seguem as propostas da moda vigente, porém ao caimento é dado significativa importância na adaptação do tecido ao modelo proposto. A dinâmica atual da moda exige agilidade das pequenas e médias empresas nacionais nos processos de compra do tecido, prototipagem e confecção com variedades de modelos e produção limitada. Entretanto, não se utilizam todos os recursos tecnológicos disponíveis em laboratórios têxteis equipados com aparelhos e pessoas especializadas na leitura dos dados. Devido ao acesso restrito, em função da logística e custos operacionais, o profissional seleciona o tecido a partir de amostras físicas, em uma avaliação subjetiva e pessoal, baseada na experiência com desenvolvimento de produto. O processo é dificultado na comunicação a distância, pois, mesmo com uma amostra do tecido em mãos, o diálogo é dificultado pela falta de parâmetros comuns de classificação e descrição das características visuais de caimento do tecido. Nesse contexto, o presente trabalho, disponibiliza um instrumento – Graduador Brehm e sua metodologia - para a classificação da maleabilidade dos tecidos em graus de caimento e a padronização dos seus termos descritores. / The consumer of manufactured textiles perceives the quality of the clothes taking the aesthetics, the fit, the feel and durability into account. Color and texture, together with the fit, contribute to the beauty of the garment. When selecting the material for clothing manufacture, those features follow the current fashion proposals: however, the fit – how the cloth hangs in loose folds – plays a very significant role when adapting the material to the proposed model. The present fashion dynamics calls for agility in the small and medium-sized national companies in the processes of buying material, prototyping and manufacturing a variety of models with limited production. However, all the available technological resources are not being used in textile laboratories equipped with devices and counting on personnel specialized in reading the data. Due to the restricted access because of the logistics and operational costs, the professional selects the material based on physical samples – a subjective and personal evaluation counting on their experience with product development. That process becomes more difficult when it is discussed from a distance. Even when one has a sample of the fabric in their hands, the dialog becomes more difficult when there are no common parameters for the classification and description of the visual characteristics for cloth hanging. For that context, this study provides an instrument – the Brehm grader and its methodology – for the classification of fabric malleability in degrees of hanging in loose folds and the standardization of the terms described.
93

Estudo de procedimentos para avaliação do PCN de pavimentos aeroportuários.

René Antonio Roehrs 00 December 2002 (has links)
O estudo trata da avaliação de pavimentos aeroportuários para notificação do PCN. São estudados cinco aeroportos brasileiros, onde o Falling Weight Deflectometer (FWD) é usado para medir as deflexões do pavimento. O programa Laymod-3 é utilizado para a retroanálise dos módulos de elasticidade das camadas, e seus resultados são analisados. Quatro grupos de pavimentos são estudados: flexíveis, rígidos, compostos e semi-rígidos. Com base nos módulos de elasticidade das camadas dos pavimentos, obtidos por retroanálise, procede-se a avaliação do PCN com a utilização de uma variada gama de procedimentos e critérios para previsão de desempenho e projeto de pavimentos, para três níveis de tráfego. Os resultados são cuidadosamente analisados para definir quais critérios definem melhor a resistência do pavimento, em cada caso. Os procedimentos mais adequados foram aplicados no aperfeiçoamento do Programa PCN.
94

Projeto de carga eletrônica para caracterização de painéis fotovoltaicos. / Design of an electronic load for photovoltaic module characterization.

Hassem, Moreno Addad 19 May 2015 (has links)
A geração solar fotovoltaica em painéis de silício tem se destacado como uma maneira limpa e renovável de atender à demanda por energia elétrica. Este trabalho apresenta o projeto, construção e testes de um sistema autônomo para obtenção da curva IV e caracterização de painéis fotovoltaicos comerciais instalados em campo. Após um estudo do problema de medição de painéis solares, uma especificação da Solução foi concebida. Com base na especificação, foram realizados o projeto elétrico, a construção de protótipos, a escrita do software de medição e os testes de validação em laboratório. Para validação definitiva do hardware desenvolvido, foram realizados testes em campo utilizando um painel solar comercial. Após a tomada de dados e análise dos resultados, conclui-se que o dispositivo concebido atende aos requisitos especificados e cumpre sua proposta inicial. A metodologia empregada neste trabalho pode ser utilizada para geração de outros instrumentos com finalidade similar ou idêntica. / Photovoltaic solar generators, using silicon panels, have grown popular as a clean and renewable way to supply electrical energy. This work presents the project, construction and testing of an autonomous system for IV curve tracing and characterization of commercial photovoltaic panels deployed in the field. After a study how to properly measure solar panels, a Solution was put in a form of a specification. From specifications, the following phases took place: electrical project, prototype construction, software development and lab testing. To perform final validation of the developed hardware, a field test with a commercial solar panel was performed. After collecting and analyzing data from, it was concluded that the design fulfills the required specifications and intended goals. The methodology employed in this work and be utilized to generate other measuring instruments with similar or identical function.
95

Sistema de caracterização de depósitos sedimentares em função das respostas latentes acústica, elétrica e térmica

Laskoski, Gustavo Theodoro 25 July 2014 (has links)
CAPES / Esse trabalho tem como objetivo geral o estudo e integração de vários sensores na caracterização de depósitos sedimentares. As técnicas correntes de análise sedimentar são tipicamente caracterizadas por análises descritivas in situ e por técnicas laboratoriais \textit{a posteriori}. Em alguns casos, algumas respostas obtidas em laboratório não podem ser explicadas pela descrição realizada in situ, resultando em falsos positivos e até na necessidade de novas coletas. Um sistema que integre sensores e técnicas para análises sedimentares in situ serve como uma ferramenta de auxílio, onde a resposta fornecida pelo analisador sedimentológico independe do pesquisador que utilizará o equipamento. Além disso, os resultados serão fornecidos no momento da coleta e qualquer resultado fora da normalidade poderá ser comparado com uma nova análise no mesmo instante. O sistema de aquisição desenvolvido integra as respostas de sensores acústicos, elétricos e térmicos. Os sensores são montados numa placa de fibra de vidro e as placas são inseridas no depósito sedimentar. Uma primeira análise consiste em avaliar a resposta acústica. Nessa técnica duas placas sensoras separadas por uma determinada distância são utilizadas, onde um sinal elétrico é utilizado para geração do sinal acústico numa placa e é realizada a leitura do sinal acústico na outra placa sensora. A mesma proposta foi replicada para um sistema de eletrodos para avaliar a impedância elétrica do depósito sedimentar. Além disso, são utilizados sensores capacitivos para avaliar a variação da impedância em função das características do depósito sedimentar. Uma outra técnica empregada avalia a resposta térmica. Nesse caso, um conjunto de resistores são utilizados para aquecer o depósito sedimentar e um conjunto de termistores são utilizados para avaliar a variação térmica nas próximidades dos sensores. Nesse trabalho foram realizados testes para verificar a variação dos sensores utilizados nas situações limites de baixo e elevado grau de saturação de água nos depósitos sedimentares. Com base nos testes realizados, o sistema permite medir o grau de saturação de água em função das respostas elétrica e térmica. Nos ensaios de laboratório foram observadas grandes variações para diferentes tipos de solo, podendo ser utilizado na classificação de solos. Além disso, o sistema desenvolvido apresentou mostrou aplicabilidade no monitoramento ambiental, podendo ser utilizado na avaliação espaço-temporal da irradiação solar, temperatura e umidade do solo. / This work describes overall integration of various sensors and geotechnical characterization of sediments. The techniques of analysis are typically characterized by in situ descriptions and laboratory techniques. Sometimes, laboratory responses cannot be explained by descriptions performed in situ, resulting in false positives and the necessity of new measurements. The proposal of a system that integrates sensors and geotechnical analysis in situ provides a better response due to results independent of researcher. Furthermore, the results will be provided in real time and some measurements errors can be easily detected. In this work, the developed system integrates responses of acoustic, electrical, and thermal sensors. The sensors were built in a plate of fiberglass and they are inserted into sediments. A first proposal is the evaluation of acoustic response. In this situation, two sensing plates separated by a given distance is used, where an electric signal is used to generates an acoustic signal and a piezoelectric crystal in the other sensor plate is used to detected received signal. The same setup was employed in a set of electrodes, where an electrical signal is applied into two electrodes arranged in two separate plates and the electrical impedance response is evaluated . Besides that, capacitive sensors are inserted into sediments to measure electrical impedance as a function of the characteristics of sedimentary deposit. Other developed system evaluates the thermal response. In this sensor, a set of resistors is used to heat the sediments and a set of thermistors is used to measure temperature variation. In this work, some tests were performed to evaluate the varition of sensors in situations of low and high degree of water saturation. In addition, it is presented the developed instrumentation. Based on the tests performed, developed system allows the measurement of water saturation based on the electrical and thermal responses. Besides that, laboratory tests show variations for different types of soil, where it can be used for soil classification. Furthermore, the system can be used in environmental monitoring, where solar irradiation, temperature, and soil moisture data can be evaluated.
96

Uma Contribuição aos Sistemas de Monitoramento de Integridade Estrutural Baseados na Impedância Eletromecânica

Baptista, Fabricio Guimarães [UNESP] 08 January 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-01-08Bitstream added on 2014-06-13T18:40:52Z : No. of bitstreams: 1 baptista_fg_dr_ilha.pdf: 1105245 bytes, checksum: d9df8c940603a26591e01168eaac4aaa (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A técnica da impedância eletromecânica (E/M) tem sido amplamente pesquisada para o desenvolvimento de sistemas de SHM (Structural Health Monitoring – monitoramento de integridade estrutural) em diversas aplicações. Embora existam muitos trabalhos que indiquem a eficiência e a viabilidade dessa técnica, alguns problemas práticos em aplicações reais ainda precisam ser investigados. A medição da impedância elétrica, etapa básica da técnica, geralmente é realizada por instrumentos comerciais volumosos, pesados e de alto custo, características proibitivas para muitas aplicações. A seleção da faixa de frequência em que a impedância deve ser medida para assegurar boa sensibilidade ao dano é feita por métodos de tentativa e erro ou por metodologias que utilizam dados medidos em uma quantidade considerável de testes. Além disso, o dimensionamento dos transdutores é feito sem um embasamento teórico, independentemente das características da estrutura monitorada. Neste trabalho é proposto um sistema de medição de impedância elétrica rápido, versátil e de baixo custo que substitui com eficiência os instrumentos comerciais. A partir de um circuito eletromecânico equivalente, o efeito de carregamento do transdutor devido à estrutura monitorada foi analisado. A análise do efeito de carregamento permite dimensionar corretamente o transdutor de acordo com a estrutura monitorada e assegurar um bom desempenho do sistema. O circuito eletromecânico também foi utilizado para determinar, teoricamente, as faixas de frequência em que o transdutor tem boa sensibilidade e auxiliar na seleção da faixa de frequência adequada para a detecção de danos estruturais. Todas as metodologias propostas foram verificadas através de experimentos em estruturas de alumínio e houve uma boa concordância entre os resultados teóricos e experimentais / The electromechanical (E/M) impedance technique has been widely studied for the development of Structural Health Monitoring (SHM) systems in various applications. Although there are many studies indicating the effectiveness and feasibility of this technique, some practical issues in real applications yet should be investigated. The electrical impedance measurement, basic stage of the technique, is usually performed by bulky, heavy and expensive instruments; these features are prohibitive for many applications. The selection of the frequency range in which the electrical impedance must be measured to ensure good sensitivity for damage detection is performed by trial and error methods or by methodologies that use measured data in a considerable amount of tests. Furthermore, the design of the transducer is done without theoretical basis, regardless the characteristics of the host structure. In this work, a fast, versatile and low-cost electrical impedance measurement system was developed; the proposed system successfully replaces the conventional instruments. From an equivalent electromechanical circuit, the transducer loading effect due to the host structure was analyzed. The analysis of the loading effect allows the correct design of the transducer according to the host structure for ensure a good performance of the system. The electromechanical circuit was also used to theoretically determine the frequency ranges in which the transducer has good sensitivity and assist in the selection of the suitable frequency range for structural damage detection. All proposed methodologies were validated by experimental tests on aluminum structures and there was a good match between the theoretical and practical results
97

Infraestrutura de aquisição de dados por redes de sensores sem fios e barramentos para monitoramento do consumo de energia elétrica

Hara, Elon Cris Penteado 18 December 2013 (has links)
CAPES / Um sistema monitor de consumo de energia elétrica para setores internos de unidades consumidoras foi desenvolvido para um projeto de P&D (Pesquisa e Desenvolvimento) ANEEL (Agência Nacional de Energia Elétrica). O sistema utiliza Redes de Sensores sem Fios (RSSF) alocadas em pontos estratégicos da rede de energia elétrica e conectadas por radioenlace a um banco de dados remoto. Os sensores fornecem dados que são registrados e posteriormente acessados por um aplicativo que apresenta informativos ao usuários por meio de alertas, relatórios e interfaces gráficas. As RSSF são empregadas em sistemas de aquisição de sinais de múltiplos sensores dispersos em grandes áreas, em redes escalonáveis quanto ao número de dispositivos e flexíveis quanto a topologias, que podem ser formadas automaticamente em função das melhores rotas ou das rotas disponíveis em um dado momento. As RSSF também têm sido úteis em sistemas relacionados ao conceito da Smart Grid, oferecendo uma ferramenta “inteligente”, que permite integrar informações colhidas a partir de cargas elétricas nas unidades consumidoras ao sistema de geração e distribuição de energia, com o objetivo de melhorar o desempenho do sistema nos picos de demanda. Apesar da disponibilidade tecnológicas, dispositivos comerciais ainda são escassos no mercado, resultando em custos finais elevados para sistemas de monitoramento de consumo. Assim, para preencher esta lacuna foi desenvolvida uma configuração de infraestrutura de baixo custo, com módulos sensores interligados por barramentos I2C com uma memória compartilhada, formando um cluster que é ligado em RSSF capaz de formar redes em malha por meio do protocolo Miwi P2P (Peer to Peer). Como múltiplos sensores ocupam uma única antena para enviar dados, os custos são minimizados. Outro diferencial do método é dar acesso a sensores concentrados dentro de armários e gabinetes metálicos, que de outra forma não poderiam ser conectados em uma RSSF. / An electric power consumption monitoring system for indoor sectors of costumers was developed to an ANEELR&D project. The system uses wireless sensor networks (WSN) placed at strategic points of the power grid and connected by radio link to a remote database. The sensor provide data, that are recorded and later accessed by a software presenting information to end users through alerts, reports and graphical interfaces. The WSN systems are used to acquire signals from multiple sensors scattered over large areas, with number of devices scalable in networks and flexible topologies, which can be formed automatically choosing the best routes or available routes. The WSNs have been useful in systems related with smart grid, offering a "smart" tool that allows collect information from electric loads in consumer units to the system of generation and distribution of energy, with the aim of improving system performance at peak demand by an electric utility. Despite the availability of technological, commercial devices are still scarce in the Brazilian market, resulting in high costs for final consumption monitoring systems. Therefore, to fill a gap a new configuration was developed presenting an infrastructure affordably with sensor modules connected by I2C bus with a shared memory forming clusters that are connected in WSN but can work in mesh networks through miwi P2P (Peer to Peer) protocol. With multiple sensors sharing a single antenna to send data, costs are reduced. Another exclusive feature of this method is to give access to sensors inside of cabinets and enclosures, which otherwise would not connected to a WSN.
98

Desenvolvimento de sensores e instrumentação aplicados no projeto de equipamentos analisadores de qualidade de energia elétrica

Koizumi, Marcos Tsuyoshi 30 November 2012 (has links)
CAPES / Uma má qualidade de energia elétrica gera grandes prejuízos para a sociedade. Desta forma são utilizados equipamentos denominados analisadores de qualidade de energia elétrica para quantizar os valores destes distúrbios e assim determinar as causas destas anormalidades. O grande problema destes equipamentos é o custo elevado e geralmente são importados inviabilizando uma medição multiponto do sistema elétrico do cliente. Neste cenário, este trabalho objetiva fornecer subsídios e alternativas para o desenvolvimento de equipamentos analisadores de qualidade de energia, que consiste de um conjunto com sensores de corrente e tensão e um módulo central de processamento. No desenvolvimento de quaisquer sensores ou instrumentação surgem algumas dificuldades de condicionamento de sinal por causa das características elétricas do componente usado e principalmente por causa do ruído. Alguns meios de contornar estes problemas são a utilização de uma instalação adequada dos equipamentos de medição, blindagens eletromagnéticas e projeto de PCB’s. No caso de sensores magnéticos, a histerese, saturação magnética e as interferências por campos magnéticos externos introduzem erro de medida no sistema e para a resolução destes problemas foram adotadas configurações de sensores Hall em malha fechada e diferencial. Outro componente que pode ser usado é o sensor Flux-gate que possui potencialidade para medições de corrente de pequena ordem além de oferecer a vantagem de maior integrabilidade ao sistema medidor. Na sequência foi projetado e construído um registrador de tensão e corrente para análise de qualidade de energia elétrica, denominado PQ-Logger, que pode usar estes sensores mencionados anteriormente. O uso de um DSP e um chip para acessar um pendrive genérico permite o armazenamento destes dados. O PQ-Logger-Tran é outro equipamento que foi idealizado para armazenar trechos de transiente de média frequência. Os resultados indicam positivamente o uso conjunto destes sensores de corrente e o equipamento desenvolvido para o propósito de medição destes parâmetros de forma rápida e econômica na infraestrutura elétrica do cliente. / A poor quality power causes large losses to society. Thus it is used an equipment named power quality analyzers for magnitude measurement of these disturbances and determine the causes of these abnormality. The principal problem with these devices is the high cost and they usually are imported that invalidates multipoint measurement of client’s electrical system. In this scenario, this work aims to provide support and alternatives for the development of power quality analyzers, which consists of a set with voltage and current sensors and a central processing module. In the development of any sensors or instrumentation there are difficulties on signal conditioning generated from the used component’s electrical characteristics and principally noise. Some solutions for these problems is the use of proper measuring equipment installation, electromagnetic shielding and design of PCBs. For magnetic sensors, the hysteresis, magnetic saturation and interference by external magnetic fields introduce measurement error in the system and to solve these problems it was adopted Hall sensors in closed-loop and differential configurations. Another component that can be used is the Flux-gate sensor that has potential use in small range current measurements and offers the advantage of higher integrability in the meter system. Following is designed and built a voltage and current logger for Power quality analysis, called PQ-Logger that may utilize the sensors mentioned above. The use of a DSP and a chip for accessing a generic flash drive allows storage of these data. The PQ-Logger-Tran is other equipment that was designed to store snippets of mid-frequency transient. The results positively indicate the combined use of these current sensors and equipment developed for the measuring purpose of these parameters in a quickly and economically form in the customer‘s electrical infrastructure.
99

Medidor de pressão e dose sonora

Gazzoni, Fernando Estevam 26 February 2009 (has links)
CAPES; CNPq / O estudo dos sons e a influência que ele exerce nos seres humanos foi intensificado nas últimas décadas devido ao grande número de veículos e indústrias nos centros das grandes cidades. O equipamento usado para caracterizar o som e verificar se ele está dentro dos padrões técnicos é o medidor de intensidade sonora ou sonômetro. As normas permitem que sejam comercializados desde equipamentos que medem apenas o nível de pressão sonora até equipamentos que além do nível de pressão sonora mostram seu espectro em freqüência e pressão média a que um operador foi exposto durante a jornada de trabalho. No Brasil, a maioria dos sonômetros comercializados que não medem apenas a pressão sonora normalmente são importados. O presente trabalho visa criar um protótipo de sonômetro capaz de medir a pressão sonora, caracterizar o sinal medido na freqüência e calcular a dose a que um indivíduo é exposto. Foi desenvolvido um sonômetro do tipo 2 com curvas de resposta lenta, rápida e impulsiva, com análise espectral em freqüência usando filtros de banda de oitava e com curvas de ponderação A e C. Os testes do software desenvolvido e da resposta do circuito montado foram realizados usando a curva de ponderação C, que é quase linear e por isso melhor para verificar a resposta em freqüência do circuito eletrônico projetado. A captura das medidas com curvas de ponderação A. Nos testes de dose de ruído foi usada a curva de ponderação A. Para testes usando ondas periódicas os resultados obtidos com o sonômetro usando as curvas de resposta lenta, rápida e impulsiva apresentaram resultados iguais, conforme esperado pela norma IEC 651. O firmware apresentou boa resolução em freqüência nos testes e respondeu de forma eficiente à variação de amplitude e freqüência do sinal sonoro de entrada. Os testes de bancada foram realizados comparando o resultado do protótipo com um sonômetro comercial e a medida de alguns sinais sonoros apresentou diferença elevada entre seus valores mínimo e máximo. Esse erro deve-se ao ruído de fundo da sala de testes, do microfone utilizado e dos erros intrínsecos ao processo da Transformada Rápida de Fourier (FFT), tais como espalhamento espectral devido à descontinuidade do início e fim da janela de amostragem, número de amostras da janela. O uso do filtro de decimação intensificou os erros ao redor da freqüência de 250Hz. A dose de ruído calculada pelo sonômetro foi proporcional ao aumento da intensidade sonora da fonte, conforme registrado pelo dosímetro comercial, porém sempre registrando um valor maior que o esperado. / The study of sounds and the influence it exerts in humans has intensified in recent decades due to the large number of vehicles and industries in the centers of large cities. The equipment used to characterize the sound and compare if it is within the technical standards is the sound intensity meter or sound level meter. The standards allow marketed since equipment that only measure the sound pressure level to equipment that show pressure level spectrum in frequency and mean pressure to which an operator was exposed during the workday. In Brazil, most sound level meters marketed that measure the sound pressure, the others are usually imported. The present work aims to create a prototype of sound level meters capable of measuring the sound pressure, characterize the signal measured in the frequency and calculate the dose to which an individual is exposed. We developed a sonometer type 2 with slow, fast and impulsive response curves, with spectral analysis using frequency filters and octave band weighting curves A and C. The testing software developed and the response of the developed circuit were performed using the C weighting curve, which is almost linear and therefore best to check the frequency response of the electronic circuit designed. In tests of noise dose and sound pressure level was used weighting curve A. For tests using periodic waves the results obtained with the sound level meter using the response curves of slow, fast and impulsive showed similar results, as expected by IEC 651. The firmware had good resolution in frequency in testing and responded efficiently to fluctuations in the amplitude and frequency of the sound signal input. The bench tests were performed comparing the results of the prototype with a marketed sonometer and some measure of sounds presented high difference in their minimum and maximum values. This error is due to the background noise of the testing room, the microphone used and the errors inherent to the process of fast Fourier transform (FFT), such as spread spectrum due to the discontinuity at the beginning and end of the sampling window, number of samples of the window. The use of the decimation filter intensified errors around the frequency of 250Hz. The calculated noise dose meter reading was proportional to the increase in the intensity of the sound source, as recorded by the marketed dosimeter, but recording a value greater than expected.
100

Medidor de pressão e dose sonora

Gazzoni, Fernando Estevam 26 February 2009 (has links)
CAPES; CNPq / O estudo dos sons e a influência que ele exerce nos seres humanos foi intensificado nas últimas décadas devido ao grande número de veículos e indústrias nos centros das grandes cidades. O equipamento usado para caracterizar o som e verificar se ele está dentro dos padrões técnicos é o medidor de intensidade sonora ou sonômetro. As normas permitem que sejam comercializados desde equipamentos que medem apenas o nível de pressão sonora até equipamentos que além do nível de pressão sonora mostram seu espectro em freqüência e pressão média a que um operador foi exposto durante a jornada de trabalho. No Brasil, a maioria dos sonômetros comercializados que não medem apenas a pressão sonora normalmente são importados. O presente trabalho visa criar um protótipo de sonômetro capaz de medir a pressão sonora, caracterizar o sinal medido na freqüência e calcular a dose a que um indivíduo é exposto. Foi desenvolvido um sonômetro do tipo 2 com curvas de resposta lenta, rápida e impulsiva, com análise espectral em freqüência usando filtros de banda de oitava e com curvas de ponderação A e C. Os testes do software desenvolvido e da resposta do circuito montado foram realizados usando a curva de ponderação C, que é quase linear e por isso melhor para verificar a resposta em freqüência do circuito eletrônico projetado. A captura das medidas com curvas de ponderação A. Nos testes de dose de ruído foi usada a curva de ponderação A. Para testes usando ondas periódicas os resultados obtidos com o sonômetro usando as curvas de resposta lenta, rápida e impulsiva apresentaram resultados iguais, conforme esperado pela norma IEC 651. O firmware apresentou boa resolução em freqüência nos testes e respondeu de forma eficiente à variação de amplitude e freqüência do sinal sonoro de entrada. Os testes de bancada foram realizados comparando o resultado do protótipo com um sonômetro comercial e a medida de alguns sinais sonoros apresentou diferença elevada entre seus valores mínimo e máximo. Esse erro deve-se ao ruído de fundo da sala de testes, do microfone utilizado e dos erros intrínsecos ao processo da Transformada Rápida de Fourier (FFT), tais como espalhamento espectral devido à descontinuidade do início e fim da janela de amostragem, número de amostras da janela. O uso do filtro de decimação intensificou os erros ao redor da freqüência de 250Hz. A dose de ruído calculada pelo sonômetro foi proporcional ao aumento da intensidade sonora da fonte, conforme registrado pelo dosímetro comercial, porém sempre registrando um valor maior que o esperado. / The study of sounds and the influence it exerts in humans has intensified in recent decades due to the large number of vehicles and industries in the centers of large cities. The equipment used to characterize the sound and compare if it is within the technical standards is the sound intensity meter or sound level meter. The standards allow marketed since equipment that only measure the sound pressure level to equipment that show pressure level spectrum in frequency and mean pressure to which an operator was exposed during the workday. In Brazil, most sound level meters marketed that measure the sound pressure, the others are usually imported. The present work aims to create a prototype of sound level meters capable of measuring the sound pressure, characterize the signal measured in the frequency and calculate the dose to which an individual is exposed. We developed a sonometer type 2 with slow, fast and impulsive response curves, with spectral analysis using frequency filters and octave band weighting curves A and C. The testing software developed and the response of the developed circuit were performed using the C weighting curve, which is almost linear and therefore best to check the frequency response of the electronic circuit designed. In tests of noise dose and sound pressure level was used weighting curve A. For tests using periodic waves the results obtained with the sound level meter using the response curves of slow, fast and impulsive showed similar results, as expected by IEC 651. The firmware had good resolution in frequency in testing and responded efficiently to fluctuations in the amplitude and frequency of the sound signal input. The bench tests were performed comparing the results of the prototype with a marketed sonometer and some measure of sounds presented high difference in their minimum and maximum values. This error is due to the background noise of the testing room, the microphone used and the errors inherent to the process of fast Fourier transform (FFT), such as spread spectrum due to the discontinuity at the beginning and end of the sampling window, number of samples of the window. The use of the decimation filter intensified errors around the frequency of 250Hz. The calculated noise dose meter reading was proportional to the increase in the intensity of the sound source, as recorded by the marketed dosimeter, but recording a value greater than expected.

Page generated in 0.1087 seconds