881

Automation of the acquisition system of the 1,9 m telescope for the charge coupled device (CCD) camera

Carter, DB January 1988 (has links)
Thesis (Master Diploma (Electrical Engineering))-- Cape Technikon, Cape Town, 1988 / This thesis describes the control system developed to improve the efficiency of star acquisition on a ground-based optical telescope. "Star Acquisition" refers to the process of identifying the star of interest in a field of stars and centering it on the optical axis of the telescope , as well as setting an autoguider detector on a suitable star so the autoguider can improve the tracking performance of the telescope. Efficiency is improved by making all functions remote controlled , so the astronomer does not have to move between the control room and the telescope to operate the instrument.
882

Development of an electronic message display

Simon, Nandor Juan January 1993 (has links)
Thesis (Masters Diploma (Electrical Engineering)--Cape Technikon, Cape Town, 1993 / In the last decade the advertising industry has developed into an advanced science which increasingly relies on the use of electronic utilities and modern technology. The advent of the microcontroller has made it possible to incorporate electronic intelligence into advertising utilities. This thesis describes the design, development and functioning of a stand alone programmable electronic message display as required by the Electrical Engineering Department of the Cape Technikon.
883

Análise radiográfica da modelagem de canais radiculares ovalados realizada com sistemas rotatórios de níquel-titânio /

Croti, Hugo Ricardo. January 2008 (has links)
Orientador: Marcelo Gonçalves / Banca: Mário Tanomaru Filho / Banca: Carlos Alberto Herrero de Morais / Resumo: O objetivo deste estudo foi analisar radiograficamente a modelagem de canais radiculares ovalados realizada com três sistemas rotatórios de níqueltitânio. Foram utilizados 60 incisivos inferiores inseridos em blocos acrílicos, que acoplados a um sistema de plataforma radiográfica, permitiu a obtenção de imagens antes e após o preparo biomecânico, em sentido mésio-distal e vestíbulo-lingual. Um meio de contraste radiológico foi utilizado para preenchimento dos canais radiculares, proporcionando visualização mais adequada destes nas imagens radiográficas. Para o preparo biomecânico, os dentes foram divididos em três grupos (n=20), numericamente equivalentes, de acordo com o sistema rotatório utilizado. O grupo I foi instrumentado com o sistema Protaper Universal, tendo os instrumentos modeladores acionados em brushing motion e como último instrumento empregado para o preparo apical o F3. O grupo II foi instrumentado com o sistema Race, tendo os instrumentos Pré-Race acionados em brushing motion e como último instrumento empregado no preparo apical o #30/0,06. O grupo III foi instrumentado com o sistema K3, tendo todos os instrumentos acionados em pecking motion e como último instrumento utilizado no preparo apical o #30/0,06. As radiografias periapicais, contendo as imagens antes e após o preparo biomecânico, em ambos os sentidos, foram processados automaticamente e digitalizados em um scanner de plataforma. As imagens resultantes foram arquivadas no programa Adobe Photoshop 7.0 e importadas para o software Image tool 3.0. Avaliou-se o aumento percentual de área dos canais radiculares nos terços cervical, médio e apical, resultante em cada grupo experimental, nos sentidos mésio-distal e vestíbulo-lingual. / Abstract: The aim of this study was radiographically analyze the shaping of oval root canals obtained by utilization of three nickel-titanium rotary systems. It was conducted on 60 mandibular incisors embedded in acrylic blocks and connected to a radiographic platform system for achievement of images, before and after biomechanical preparation, in mesiodistal and buccolingual directions. A radiographic contrast medium was used for root canal filling, which allowed more adequate visualization on the radiographic films. For biomechanical preparation, the teeth were divided into three numerically equivalent groups according to the rotary system employed. Group I was instrumented with the system Protaper Universal, by utilization of shaping instruments in brushing motion and apical preparation finalized with an instrument F3. Group II was instrumented with the system Race, by utilization of Pre-Race instruments in brushing motion and apical preparation finalized with an instrument #30/0,06. Group III was instrumented with the system K3, by utilization of all instruments in pecking motion and apical preparation finalized with an instrument #30/0,06. The periapical radiographies containing the images before and after biomechanical preparation in both views were automatically developed and digitized on a platform scanner. The resulting images were stored in the software Adobe Photoshop 7.0 and imported to the software Image Tool 3.0. The percent increase in the root canal area was analyzed at the cervical, middle and apical thirds, for each study group, in both mesiodistal and buccolingual directions. Occasional changes in the original proportion between the buccolingual and mesiolingual areas, caused by biomechanical preparation, were also analyzed for each third. Data were analyzed by analysis of variance one-way and Tukey test at a significance level of 5% (p<0.05). / Mestre
884

Eletroestimulador funcional de oito canais com malha de realimentação utilizando Controlador Digital /

Junqueira, Marcos Vinícius Nascimento. January 2013 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Carlos Antonio Alves / Banca: Uender da Costa Faria / Resumo: Foi desenvolvido um Eletroestimulador Funcional Microcontrolado para geração de movimentos nos membros inferiores de paraplégicos, visando acelerar o processo de reabilitação. O estimulador neuromuscular é constituído por oito canais microcontrolados, com formas de onda de corrente bifásica, retangular e carga balanceada, com capacidade para fornecer correntes com amplitude de até 140 mA, utilizando modulação por largura de pulso (PWM). Foi implementado um controlador Proporcional Integral Derivativo (PID) embarcado para uso com o eletroestimulador, sendo possível determinar a energia a ser aplicada ao membro estimulado, de forma a mantê-lo em uma posição pré-estabelecida. O projeto desse controlador se baseou em um modelo matemático linear de segunda ordem, que representa o comportamento da força muscular devido a um estímulo elétrico. Para validação e teste do funcionamento do sistema, funções matemáticas que descrevem o comportamento fisiológico do membro inferior foram representadas por circuitos eletrônicos. Desta forma, neste projeto foi possível integrar o controlador, o estimulador e o modelo fisiológico do músculo, observando-se a resposta temporal durante a eletroestimulação, descartando, inicialmente, a realização de testes com pessoas, visando preservar a integridade física dos voluntários. Após a verificação do bom funcionamento do equipamento, realizou-se testes com voluntários aplicando o controle em malha fechada / Abstract: A Microcontrolled Functional Electrical Stimulation (FES) system was developed for generating movements in the lower limbs of paraplegics in order to accelerate their rehabilitation process. The neuromuscular stimulator consists of eight channels, microcontrolled, rectangular, biphasic current waveform, balanced load, with the ability to deliver current with amplitude of 140 mA using pulse width modulation (PWM). A PID controller was implemented for using with the microcontrolled stimulator, and the energy to be applied to the stimulated member can be determined in order to keep the leg in a pre-determined position. The design of this controller was based on a linear second order mathematical model, which describes the behavior of a muscle strength due to an electrical stimulus. For validation and testing the microcontrolled electrical stimulator system, mathematical functions that represent the physiological behavior of the lower limbs were represented by electronic circuits. Thus, this project integrates the controller, the stimulator and the muscle model, observing the time response during electrical stimulation, avoiding testing it with patients and preserving the physical integrity of the volunteers. After verifying the proper operation of the equipment, tests with volunteers were carried out applying closed loop control / Mestre
885

Resistência à flexocompressão de instrumentos endodônticos indicados para canais atresiados e sua correlação com as características morfométricas / Buckling resistance of pathfinders and its geometry

Georgiana Amaral 07 April 2009 (has links)
O objetivo deste estudo foi avaliar a resistência à flexocompressão (flambagem) de instrumentos endodônticos empregados no cateterismo de canais radiculares atresiados e se esta varia conforme o comprimento. Flambagem é a deformação lateral apresentada por um instrumento quando submetido a uma força compressiva na direção de seu longo eixo. Foram utilizados instrumentos endodônticos C+File n 10, K-File n 10 (Dentsply-Maillefer, Suíça); CC+ n 10 e C-Pilot n 10 (VDW, Alemanha), HI-5 n 10 (Miltex, EUA), Pathfinder CS K2 e Pathfinder SS (SybronEndo, EUA), sendo dez amostras de cada marca comercial em diferentes comprimentos. As dimensões dos instrumentos, tais como diâmetros, comprimento útil, comprimento da parte de trabalho, conicidades, ângulos de inclinação das hélices, ângulo da ponta, forma de seu vértice e presença de ângulo de transição foram determinadas por meio de um microscópio óptico com dispositivo micrométrico acoplado a um computador (Pantec, Panambra, Brasil). Detalhes da forma das pontas e forma das seções retas transversais foram obtidas por meio de um microscópio eletrônico de varredura (MEV - JEOL, JSM-5800, Tókio, Japão). O ensaio de flambagem foi realizado empregando-se uma máquina de ensaio universal (EMIC, DL 10.000, Paraná) e consistiu na aplicação de uma força crescente na direção axial dos instrumentos avaliados, sendo registrada por um software até o deslocamento de 1 mm. A análise dos resultados pelo ANOVA e Tukey revelou que a força máxima para flambar os instrumentos foi maior para os da marca comercial C+File tendo os instrumentos Pathfinder SS apresentado os resultados menos favoráveis. Provavelmente a geometria, que se mostrou completamente distinta para cada grupo de instrumentos, influenciou no comportamento dos mesmos, embora o comprimento não tenha interferido na resistência à flexocompressão. / The aim of this study was to evaluate the buckling resistance of endodontic intruments during the pathfinding of constricted root canals and its lenght influence. Buckling is the elastic deformation of an instrument due to the compressive strenght in its axial direction. The instruments surveyed and tested were: C+File #10, K-File #10 (Maillefer, Switerzland), CC+#10, C-Pilot #10 (VDW, Germany), HI-5 #10 (Miltex, USA) and Pathfinder CS K2 and SS (SybronEndo, USA). Ten instruments from different brands with different lenghts were measured through a optical microscope (Pantec, Panambra, Brazil) aiming to register the diameters, total and useful lenght, taper, helical angles and tip angle, whereas tip details and cross sections were obtained through an electronic microscope MEV (JEOL, JSM-5800). The buckling test was performed at an universal testing machine (EMIC, DL 10.000, Brazil). The maximum load during the elastic deformation was measured by a software while applying increasingly pressure in the axial direction of each instrument till a 1mm deformation. The ANOVA e Tukey test analized the results and revealed that the C+File presented the highest buckling resistance while Pathfinder SS presented the worst results. Different designs might interfere with the results but, in general, the lenght did not have statistical influence.
886

Finanční aktiva, finanční investice a finanční nástroje podle mezinárodních účetních standardů / Financial assets, financial investments and financial instruments under the International Accounting Standards

MATAJSOVÁ, Jana January 2008 (has links)
Cílem práce bude vysvětlit nejnovější úpravu vykazování finančních aktiv a finančích závazků včetně derivátů pro potřeby účetní závěrky sestavované podle mezinárodních standardů finančního výkaznictví. Součástí práce bude i naznačení podmínek pro tzv. zajišťovací účetnictví.
887

Análise dos critérios de outorga de direito de usos consuntivos dos recursos hídricos baseados em vazões mínimas e em vazões de permanência. / Analysis of grant criteria based on minimum flow and flow according to duration curve for water consumptive uses.

Ludmilson Abritta Mendes 16 May 2007 (has links)
A Política Nacional de Recursos Hídricos acaba de completar dez anos, período ao longo do qual novos desafios se apresentaram ao gerenciamento dos recursos hídricos à medida que se consolidou a aplicação dos instrumentos de gestão, dentre eles a outorga de direito de uso. Os critérios comumente aplicados na determinação da disponibilidade hídrica para outorga, ao fixarem vazões muito restritivas como quantidade máxima outorgável, se mostraram inadequados à realidade de algumas bacias, que, em pouco tempo, se apresentaram com disponibilidade hídrica crítica ou em vias de criticidade, tendo a somatória das demandas consuntivas alcançado a restrita parcela destinada à outorga estabelecida em legislação. Neste trabalho buscou-se apresentar as inconveniências relacionadas ao uso da vazão mínima de 7 dias com 10 anos de recorrência - Q7,10 - e das vazões de permanência como referência para outorga. Através das leituras de vazões diárias de dois postos fluviométricos da bacia hidrográfica do rio Turvo, em São Paulo, já considerada crítica quanto à disponibilidade hídrica, foi calculada a Q7,10 por ajustes obtidos por quatro distribuições probabilísticas, e também foi construída a curva de permanência de vazões de ambos os postos. Os resultados foram usados no cálculo da vazão outorgável segundo os critérios estaduais baseados em vazão mínima e em vazão de permanência. Discutem-se, então, as imprecisões associadas à Q7,10 e às vazões de permanência em vários aspectos, bem como as inconveniências de se fixar um teto exíguo e universal de outorga a perfis de demandas distintos. Sugere-se, por fim, o abandono destes critérios de outorga e, a partir de algumas experiências de gestão de bacias críticas, apontam-se caminhos alternativos mais adequados, em especial a outorga negociada. / Through these ten years of the Water Resources Brazilian Policy, some difficulties have been presented to the water resources management in so far as the management instruments has becoming solid, mainly to the grant of right for using water resources. A problem of those refers to the low water availability in several water basins, where the total water demands exceed the maximum volume permitted in agreement with the law. This situation occurs by the state criteria which impose low limits for the surface outflows, expressed by minimum flow or flow according to duration curve. This work analyses the constraints when the hydrologic water availability is referred to the Q7,10 (minimum flow with duration of 7 days duration and 10 years of return period), to Q95% (flow equalized or overstated in 95% of the time) or to Q90%. These flows were calculated from the daily records in two hydrological stations located at Turvo River, State of São Paulo, where the consumptive uses are higher than the water availability. The Q7,10 flow was obtained through four probabilistic methods. Also the duration curves were obtained and the results was used to determine the maximum value granted according to state criteria referred to Q7,10, Q95% and Q90% flows. Then, it\'s argued the imprecision related to these three flows in several aspects and the inconvenience of fixing an scanty and universal ceiling to different demands profiles. In conclusion, it\'s suggested the substitution of these criteria and, through some cases of management of critical basins, it\'s pointed alternative methods of grant of right for using water resources.
888

Aplicacao de metodologia de testes de desempenho para monitores portateis de radiacao

VIVOLO, VITOR 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:07Z (GMT). No. of bitstreams: 1 07009.pdf: 4378283 bytes, checksum: 79cafd4e124d9349d8fbb819d59b5959 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
889

Estabelecimento de um novo metodo de calibracao de camaras de ionizacao tipo lapis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

DIAS, DANIEL M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:14Z (GMT). No. of bitstreams: 0 / As câmaras de ionização tipo lápis são utilizadas para dosimetria de feixes em equipamentos de tomografia computadorizada (CT). Neste estudo foi estabelecida uma nova metodologia de calibração destas câmaras, visando a adequação do Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI) aos atuais padrões metrológicos internacionais que tratam dos procedimentos específicos para calibração das câmaras utilizadas em CT. Primeiramente partiu-se da implantação das novas qualidades de radiação padrão RQT, que simulam feixes não atenuados usados para aplicações em CT, de acordo com a IEC 61267 da International Electrotechnical Commission (IEC). Após o estabelecimento dos campos padrões de radiação, foi implantada a metodologia de calibração específica para câmaras lápis segundo o Technical Report Series No. 457, da International Atomic Energy Agency (IAEA), que descreve as particularidades do procedimento a ser seguido pelos Laboratórios de Dosimetria Padrão Secundário (SSDLs) em termos de colimação e posicionamento em relação ao feixe de radiação. Inicialmente, foram realizadas medições de PPV (kV) e determinação das filtrações adicionais de cobre por meio dos valores de camada semi-redutora (CSR) recomendados pela norma IEC 61267, para que as qualidades de radiação de referência: RQT 8, RQT 9 e RQT 10 fossem implantadas. Para os filtros adicionais, foram utilizados alumínio e cobre de alta pureza (maior ou igual a 99,9%). Uma metodologia alternativa para determinar as filtrações adicionais também foi utilizada, através da qual se encontrou diretamente as RQTs em espessuras de filtros de cobre equivalente ao conjunto RQR (Al) + Filtração Adicional (Cu), sendo esta uma opção quando não se têm implantadas as RQRs. Com a implantação desta nova metodologia de calibração das câmaras de ionização tipo lápis, o LCI está pronto para calibrar estes instrumentos de acordo com as recentes recomendações internacionais. Permitindo assim uma melhoria na rastreabilidade das calibrações, como também na qualidade dos serviços metrológicos que o IPEN oferece para todo o País. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
890

Implantacao de um programa de controle de qualidade em equipamentos de raios X por meio de medidores nao invasivos / Establishment of an X radiation equipment quality control programme using non invasive meters

LUCENA, RODRIGO F. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:44Z (GMT). No. of bitstreams: 0 / O objetivo desse trabalho foi estudar o comportamento do principal equipamento de raios X utilizado nos procedimentos do laboratório de calibração do IPEN, LCI, operado nos intervalos de tensão de 25 a 150 kV utilizando os medidores de tensão não invasivos DiavoltTM da PTW e do sistema de espectrometria ORTEC, modelo NOMAD-PLUS 92X para o estabelecimento de um programa de controle de qualidade. O medidor Diavolt foi utilizado para as medições de kerma no ar, tensão de pico e tensão de pico prático. As medições foram feitas variando parâmetros como, corrente elétrica, Qualidade de Radiação X para Radiodiag-nóstico, angulação do medidor e sua distância em relação ao ponto focal do aparelho de raios X. Os resultados encontrados foram comparados com dados encontrados na literatura. Com o sistema de espectrometria, foram gerados os espectros com a finalidade de determinar as tensões de pico relativas às tensões nominais escolhidas e caracterizar as Qualidades em Radiodiagnóstico determinadas anteriormente. O programa de controle de qualidade estabelecido possibilita o controle do funcionamento tanto dos instrumentos de medição (câmaras de ionização, medidor de tensão e corrente e espectrômetro), bem como do sistema de radiação X. Neste trabalho também foi sugerida a periodicidade de realização de cada um dos testes. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0811 seconds